Ordnance Factory Board Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 1,12,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MIL_145909_1Bid Award Id
ViewTender No
3012/GENL/TE-22/EO(C)/2022-23Tender Authority
Ordnance Factory Board ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Replacement of old existing electrical wiring and fitments in Type-I(old) in line with latest MES SOA at O F Badmal.
Remedial measure of safety during execution of work
Biddewrs-Compliance-TE-22-2022-23
Type-I (OLD) Internal Layout Drawing
Important Note on Electrical Work
Format for EMD Bank Guarantee (BG)
BOQ Items
M&L for point wiring in PVC conduit using PVC sheathed single core cable for one light point or one fan point controlled by one switch with PVC sheathed single core copper cable 1.5 sq mm size.
864
-
-
M&L for point wiring in PVC conduit for one bell/ buzzer point controlled by one push button on the same board with other switches or independent with PVC sheathed single core copper cable 1.5 sq.mm size.
72
-
-
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not
exc l0 cm girth.
2448
-
-
S&F of Bell, AC, 230 volts, single pole.
72
-
-
S & F of Modular Bell push 6A 1 module.
72
-
-
S & F of modular metal flush box 3 module
440
-
-
S & F of modular fan step regulator, 120W - 2 module.
216
-
-
S & F modular switch 1 way 6A, 1 module.
868
-
-
S & F modular switch 2 way 6A, 1 module.
16
-
-
Material & Labour for wiring for circuit/submain wiring alongwith earth wire of sizes 2 x 2.5 sq. mm + 1 x 2.5 sq. mm of FR PVC insulated copper conductor, single core cable in existing surface/recessed steel/PVC conduit as required.
3096
-
-
Material & Labour for wiring for circuit/submain wiring alongwith earth wire of sizes 2 x 4 sq. mm + 1 x 4 sq. mm of FR PVC insulated copper conductor, single core cable in existing surface/recessed steel/PVC conduit as required.
1152
-
-
Material & labour for wiring for circuit alongwith earth wire for size 2x 1.5 sqmm + 1x 1.5 sq.mm earth wire FR PVC insulated copper conductor single core cable in existing surface /recessed steel/PVC conduit as required for looping connection from MDB at new position to the existing staircase light point circuit (Exclusive of conduit).
177
-
-
Supply & Laying of light grade Galvanised steel tubes of diameter 50mm with all fittings laid in trenches for cable erection.
351
-
-
Excavating hard/dense soil in trenches , n exc 1.5m wide and n exc 1.5 m in depth; for foundation, etc. or shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out.
36
-
-
Demolition & Dismantling of un-reinforced cement concrete of any description and in any position not otherwise specifically provided.
16
-
-
Material & Labour for cement concrete of Type B2 1:2:4 with 40mm graded aggregate in foundations, fillings and mass concrete in the demolished concrete drain for making good.
16
-
-
Returning hard/dense soil, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm.
36
-
-
Material & Labour for 4 Core PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sq. Mm.
384
-
-
Providing cement concrete of type C 0 1:3:6 with 12.5 mm graded coarsed aggregate in the left over excavated brick wall of residential quarters for placement of distribution Boards.
3.32
-
-
Supplying & fixing of 25A double pole (Single Phase & Neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mili amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- ABB/Bajaj/Havells/Legrand/Crabtree/ V- Guard Or Equivalent.
72
-
-
Supplying & fixing of 25 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
4110
-
-
Supplying & fixing metal box of size 100 mm x 100 mm x 60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
296
-
-
Supplying & fixing of 2 module(75mm x 75mm) GI box along with modular base & cover plate for modular switches in recess etc as required.
228
-
-
Supplying & fixing of 4 module(125mm x 75mm) GI box along with modular base & cover plate for modular switches in recess etc as required.
72
-
-
Supplying & fixing of 6 module(200mm x 75mm) GI box along with modular base & cover plate for modular switches in recess etc as required.
144
-
-
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing & fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
288
-
-
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
144
-
-
Supplying & fixing 3 pin , 5 amp ceiling rose on the existing junction box block including connection as required.
440
-
-
Supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick GI plate with inscription there on, bolted/welded to 35 mm x 35 mm x 6 mm angle iron 60cm long and fixing the same in ground as required.
8
-
-
Supplying & making end termination with brass compression gland and aluminium lugs for 35 sq. mm size (4 core) PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
16
-
-
Supplying and fixing of 5 amps to 32 amps rating, single pole, 240Volts,10 KA "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
288
-
-
Supplying and fixing of 5 amps to 32 amps rating, double pole, 240Volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
72
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5star rated, ceiling fan with Brush Less Direct Current(BLDC) Motor, Class of Insulation : B, 3 Nos. Blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air Delivery minimum 215 CMM, 350 RPM(Toleranceas per IS:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessoeies including safety pin, nut bolts, washers, temperature rise=75 degree C(max), insulation resistance more than 2 Mega Ohm, Suitable for 230 V, 50 Hz, Single Phase AC Supply, Earthing etc. Complete as required.
144
-
-
Supply & fixing of standard size 2 way round GI junction box for fixing of ceiling rose on roof ceiling/wall for fan/light point wiring.
440
-
-
Supply & fixing of 240V, 50Hz 1 or 2 Module modular angle bulb holder with base plate.
432
-
-
Supply & fixing of 240V, 50Hz 1 or 2 Module modular bulb holder with back plate.
8
-
-
Removal of concealed metallic junction boxes of any description or size with board(including switches/sockets etc) and carrying to store.
512
-
-
Auguring in earth at a depth 0.75 metre to 1.5 metre in hard/dense soil for for laying of GI pipe of size upto 150mm dia.
12
-
-
Supply & fixing of duly painted 240 Volt, 50 Hz 8 way prewired single phase modular double door distribution board of approx. size (260 x 240 x 90) mm suitable for recess mounting with thickness of sheet not less than 1.6 mm. It shall have the following provisions:- (i) Earth Bar, fully shrouded Neutral Bar and ties for cable management. (ii) MCBs shall be operable manually without opening the inner door. (iii) Studs for body earthing connection. (iv) DIN rail for mounting MCBs & metallic link for MCBs . (v) The scope includes removal of existing concealed distribution board of size (450 x 620 x 200) mm. (vi) Reconnection of incoming as wellas outgoing power supply. (vii)Existing RCCBs/MCBs will be re-used for catering the power supply. (viii)The DB specifications shall be as per IEC 61439-3 or IS/BIS standards. Make:- Preferably Shall be of Legrand/V-Guard/Havells.
72
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements