Odisha University Of Agriculture And Technology Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha University Of Agriculture And Technology - OUAT Tender

Laboratory Equipment and Services
Eprocure
Opening Date31 Jul 2021
Closing Date19 Aug 2021
Tender AmountRefer Documents 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Volume per revolution : 0.309L

-

-

-

... More
Greatest pressure : 2.5 mpa

-

-

-

... More
Accuracy : ±0.2%

-

-

-

... More
Repeatability : ≤0.05%

-

-

-

... More
Standard unit : Rise

-

-

-

... More
CO2 Probe

1

-

-

... More
Exact application : Measurement of dissolved CO2 in microalgae culture

-

-

-

... More
Measurement range : 10 to 1000 mbar CO2

-

-

-

... More
Accuracy : ± (10 % of the reading + 10 mbar)

-

-

-

... More
Operating temperature :0 to 60 °C (32 to 140 °F)

-

-

-

... More
Mechanical temperature resistance : – 20 to 130°C (– 4 to 266 °F)

-

-

-

... More
Operating pressure : 0.2 to 2 bar (3 to 30 psia)

-

-

-

... More
Mechanical pressure resistance Max. : 3 bar (42 psia) at 25 °C (77 °F)

-

-

-

... More
Response time t90 : at 25 °C (77 °F) 120s

-

-

-

... More
Steam sterilizable and autoclavable : Yes

-

-

-

... More
Cable connection : AK 9

-

-

-

... More
O2 selective membrane material : PTFE / Silicone

-

-

-

... More
Shaft diameter : 12 mm

-

-

-

... More
Available lengths : 220- 320 mm

-

-

-

... More
Distance between sensor and transmitter : 40mm

-

-

-

... More
Blind transmitter : Ok

-

-

-

... More
Palletizer Machine

1

-

-

... More
Body Material : Hardened Mild Steel

-

-

-

... More
Output Capacity : 20 to 50 Kg/Hr

-

-

-

... More
Pallete Size Die : 8mm to 10mm

-

-

-

... More
Motor Power Capacity : 3 to 5 HP

-

-

-

... More
Roller : 1 set

-

-

-

... More
Palletizer Mill weight : 90 kg

-

-

-

... More
Palletizer Mill size (H x L x W): 36 x 48 x 24

-

-

-

... More
Movement of Palletizer Mill : Trolley on wheels

-

-

-

... More
Shape of Hopper : Round

-

-

-

... More
Shredder Machine

1

-

-

... More
Cutting Mechanism : Twin Shaft

-

-

-

... More
Shred Chamber (mm) : 310×310

-

-

-

... More
Shred Size (mm) : 8×50-100

-

-

-

... More
Shred capacity : 200-300 Kg/Hr

-

-

-

... More
Voltage : 415V

-

-

-

... More
Power : 3 HP

-

-

-

... More
Hopper Volume (Liters) : 60 L

-

-

-

... More
Waste Volume (Liters) : 180 L

-

-

-

... More
Weight : 275 kg

-

-

-

... More
Running Cycle : Continuous

-

-

-

... More
Soxhlet Appratus

1

-

-

... More
Automatic PC Compatible Solvent Extraction System (Digital)

-

-

-

... More
• Fully Automatic Programmable Six Place Auto sequencing PC Compatible Solvent Extraction System

-

-

-

... More
• TFT Graphic Touch Screen Display with unique wireless mouse to operate directly without connecting to PC.

-

-

-

... More
• Icons to represent output of heating process in touch screen display

-

-

-

... More
• Selectable Programs(Customizable): Integrated Auto Sequencing Features with intelligent memory programs minimum 50 programme with 10 sequencing steps with inbuilt datagger with user ID, Channel name, Scan rate, file browse feature to download stored data with inbuilt software for usable CSV and excel format

-

-

-

... More
• Data logger with real time clock with memory stick for data storage with separate port in mother board apart from PC Port

-

-

-

... More
• The advanced superior PC chart software performs live graphical representation of time / temperature gradient on touch screen display directly.

-

-

-

... More
• Temperature Range: 35°C (Ambient) to 300°C, Temperature Accuracy / Precision : + 0.5° C

-

-

-

... More
• Temperature Controller should be isolated separately in a control tower to protect electronics from solvent area & heat zone for safe operation

-

-

-

... More
• Measuring Range: 0.1 to 100% fat / oil

-

-

-

... More
• Repeatability: + 1% or better

-

-

-

... More
• Speed of extraction: 40 to 60 minutes depending on application

-

-

-

... More
• Auto Phase change of extraction includes boiling, Condensation, rinsing, solvent recovery & predrying

-

-

-

... More
• Inbuilt Airpump, SS Manifold, Automatic collection of recovered Solvent, Versatile sizes of thimble (extra thimble should be provided)

-

-

-

... More
• Upgradeable Remote control module for wireless data monitoring, control and transfer to PC at a distance of 5-10 feet. The Entire display screen of Controller should wirelessly appear in the PC/ Laptop of user, to monitor & control from his work table.

-

-

-

... More
• Electrical Requirement:230V/50Hz. AC Mains.

-

-

-

... More
Refrigerated Water Cooling Circulating system

-

-

-

... More
• Refrigerated Water Cooling Circulating system with digital display of temperature,

-

-

-

... More
• Microprocessor based PID Temp. Controller, Temperature Range: 10°Cto 20ºC.

-

-

-

... More
• Inbuilt safety features with CE Certification to fulfil all statutory requirement of Good laboratory Practice. Auto over temperature protection / Auto Error indication / Auto Sensor Break Protection, Over load protection.

-

-

-

... More
• SS Tank, Submergible pump for recirculation, MS powder coating housing

-

-

-

... More
• The instrument should be approved registered brand & shall strictly confirm to the specifications with relevant brochure & Photograph as per specification.

-

-

-

... More
Recirculating Chiller

1

-

-

... More
Temperature Range: -10~100ºC

-

-

-

... More
Precision:±0.2

-

-

-

... More
Cooling capacity at 20°C -800w

-

-

-

... More
Interior dimensions:150x160x150mm

-

-

-

... More
Chamber Volume:4.5L

-

-

-

... More
Electrical Requirement:220V 50HZ

-

-

-

... More
Pump flux:8L/min

-

-

-

... More
Power consumption : 2300W

-

-

-

... More
Microprocessor temperature controller

-

-

-

... More
Audible and visible alarm for temperature and water level

-

-

-

... More
R134a refrigerant, imported compressor With interface to external water bath

-

-

-

... More
RS485 connector to connect computer to record the parameters and the variations of temperature.

-

-

-

... More
Portable Gas Analyser (Syn-Gas)

1

-

-

... More
Method of Detection : NDIR infrared sensor for CO, CO2 and CH4 Electrochemical sensor for O2 & H2

-

-

-

... More
Ranges Available O2 0-25.0%, 0-50.0%, 0-100.0% CO 0-10.0%, 0-50.0%, 0-100.0% CO2 0-10.0%, 0-50.0%, 0-100.0% CH4 0-50.0%, 0-100.0% H2 0-5.0%

-

-

-

... More
Resolution : 0.1% for all gases

-

-

-

... More
Accuracy & Repeatability : ± 2% of reading for all gases

-

-

-

... More
Drift : Less than 2% of full scale per month

-

-

-

... More
Response Time (T-90) : 20-30 seconds to 90% step change

-

-

-

... More
Ambient Temperature Range : 4 to 50°C

-

-

-

... More
Power : 12V/24V DC adaptor

-

-

-

... More
Output Options : RS 232 interface for data logging

-

-

-

... More
Sieve Shaker with Sieve

1

-

-

... More
Heavy duty (Improved Model) for 8 Inch TEST SIEVE

-

-

-

... More
The Sieve shaker is durable constructed and is run by ¼ H.P. Electric MOTOR 220 Volts A.C. through reduction gear.

-

-

-

... More
Designed to carry upto 6/7 TEST SIEVE of 200mm Dia (8 Inch) with one set lid & pan.

-

-

-

... More
It produces circular and hammering motion is given at top.

-

-

-

... More
It reproduce circular (revolution approx.: 280 to 320 R.P.M and tapping approx.: 140 to 160 R.P.M.

-

-

-

... More
No foundation required.

-

-

-

... More
7 nos. of TEST SIEVE (Dia 8 Inch) made-up of Brass with different sizes such as 106 µm, 150 µm, 212 µm, 250 µm, 300 µm, 500 µm, 850µm.

-

-

-

... More
One set lid and pan with above specification.

-

-

-

... More
Moisture Analyser

1

-

-

... More
Max. Capacity : 50 g

-

-

-

... More
Readability (Weight): 0.1 mg

-

-

-

... More
Readability Moisture : 0.0001%

-

-

-

... More
Repeatability (Sample 2G) (SD) : 0.05%

-

-

-

... More
Repeatability (Sample 10G) (SD) : 0.02%

-

-

-

... More
Units of Measurements : %M, %D, %R (ratio), Gm/Lt, %M Atro, %D Atro

-

-

-

... More
Statistics : Method wise for each individual 40 methods or Batch wise for each individual 100 batches for last 999 results

-

-

-

... More
Technology : Infra RED Halogen

-

-

-

... More
Temperature Range : Max. to 175°C (Optional to 250ºC)

-

-

-

... More
Temperature Increment : Interval 1ºC

-

-

-

... More
Heating Profile : Standard, Gentle, Rapid, Steps, High Temperature

-

-

-

... More
Switch off Criteria : Auto, Manual

-

-

-

... More
Auto Method Development : Intelligent

-

-

-

... More
Method Memory : 40 and Batch Memory : 100

-

-

-

... More
Method Designation : Alpha Numeric

-

-

-

... More
Serial Number : Yes

-

-

-

... More
Compile : Yes (Method Linking)

-

-

-

... More
Operating Temperature : 15ºC to 35ºC

-

-

-

... More
Display : Graphical LCD Display with LED Backlite

-

-

-

... More
Filter Vacuum Pump

1

-

-

... More
Wetted parts 304 stainless steel, Free air capacity(LPM) ≥28 Max flow rate (CFM)≥ 0.99 Max flow rate (litters/min) ≥28 Max pressure (PSI)≥ 60 Max pressure(bar) ≥4.14 Max vacuum(mbar)≥ 500 Noise level(db)≥ 68 Port size ¼" NPT (F) 3/4" hose barb on gauges Noise Level : 50.00 dB

-

-

-

... More
Filtration Unit

-

-

-

... More
Material type: Glass Diameter: 50mm Capacity: Upper chamber-500 ml, 1000ml, lower chamber-500ml Sintered crucible Nylon 66 membrane & filter, filterpaper Nontoxic, unbreakable polysulfone funnel is used in microbial and particulate analysis. Funnels do not leak after repeated autoclaving Removal membrane support plate is designed to provide maximum flow rate and through put. Filtration Assembly Made of borosilicate glass with fritted glass filter base The base design has an integral vacuum connection located above the filtrate drip to prevent contamination of the vacuum line from droplets The filtration base has a silicon stopper, Anodized aluminum spring clamp Facilitates analysis of particulate or biological contamination of vacuum filtering liquid The scaled funnels simplify dosing and analysis

-

-

-

... More
Lambda 365 double beam UV Spectrophotometer compatible accessories kit

1

-

-

... More
50 mm Trans/Reflect Sphere High Sens used for measuring the diffuse reflectance (SCE), total transmittance, diffuse transmittance and performing color analysis. It has a spectral Range of 230-1100 nm (UV and visible). Its port size is 10.00 mm and the spectral bandwidth is 20nm.

-

-

-

... More
Powder sampling kit

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.