Odisha State Police Housing And Welfare Corporation Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha State Police Housing And Welfare Corporation Limited - OPHWC Tender

Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date14 Jun 2022
Closing Date28 Jun 2022
Tender Amount₹ 9,49,76,889 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
50000008 "Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. " (Ground Floor)

475.09

-

4398.8

... More
First Floor

139.51

-

4481.75

... More
Second Floor

139.51

-

4577.15

... More
Third Floor

139.51

-

4686.86

... More
Forth Floor

139.51

-

4813.02

... More
Fifth Floor

139.51

-

4958.11

... More
50000009 "Rigid and smooth centering and shuttering false, levelled works and dismentalling then after casting including cost of mterials complete for Plinth band & Column Footing. " (Ground Floor)

693.94

-

103.22

... More
50000010 " Providing and fixing,centering,shuttering of lintels including removal of form work at all depth and height." (Ground Floor)

32.35

-

258.75

... More
First Floor

102.39

-

310.5

... More
Second Floor

102.39

-

372.6

... More
Third Floor

102.39

-

447.12

... More
Forth Floor

102.39

-

536.54

... More
Fifth Floor

102.39

-

643.84

... More
50000011 "Providing and fixing,centering,shuttering of griders beams,column etc including removal of forms work at all depth and heaight. " (Ground Floor)

930.13

-

724.08

... More
First Floor

668.77

-

868.9

... More
Second Floor

668.77

-

1042.68

... More
Third Floor

668.77

-

1251.22

... More
Forth Floor

668.77

-

1501.47

... More
Fifth Floor

668.77

-

1801.77

... More
50000012 "Providing and fixing,centering,shuttering of R.C.C walls and fins etc.including removal of forms work at all depth and height. " (Ground Floor)

147.01

-

619.02

... More
First Floor

53.39

-

742.83

... More
Second Floor

53.39

-

891.4

... More
Third Floor

53.39

-

1069.68

... More
Forth Floor

53.39

-

1283.62

... More
Fifth Floor

53.39

-

1540.34

... More
50000013 "Providing and fixing,centering,shuttering of R.C.C. slabs, staircase,Chajja,including removal of form work at all depth and height. " (Ground Floor)

422.72

-

422.1

... More
First Floor

514.02

-

506.52

... More
Second Floor

514.02

-

607.82

... More
Third Floor

514.02

-

729.38

... More
Forth Floor

514.02

-

875.25

... More
Fifth Floor

514.02

-

1050.3

... More
50000017 "Supplying of filling sand in foundation and plinth including watering,ramming,consolidating and dressing,labours,tools, taxes etc., all complete as per the specification and direction of E.I.C. " (Ground Floor)

611.67

-

464.94

... More
50000020 "12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curring etc. All complete at all depth and height. for out side portion wall. " (Ground Floor)

508.23

-

135.67

... More
First Floor

1324.65

-

141.1

... More
Second Floor

1324.65

-

146.81

... More
Third Floor

1324.65

-

152.8

... More
Forth Floor

1324.65

-

159.09

... More
Fifth Floor

1324.65

-

165.69

... More
50000021 "6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smmoth including closed deep chiping and slurry treatment with necessary scaffolding,curring etc. All complete at all depth and height.for inside and out side portion. " (Ground Floor)

1028.85

-

151.36

... More
First Floor

696.58

-

155.16

... More
Second Floor

696.58

-

159.08

... More
Third Floor

696.58

-

163.12

... More
Forth Floor

696.58

-

167.28

... More
Fifth Floor

696.58

-

171.56

... More
50000022 "16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand)including necessary scaffolding curring etc. all complete at all depth and height. " (Ground Floor)

326.52

-

193.89

... More
First Floor

605.14

-

198.73

... More
Second Floor

605.14

-

203.72

... More
Third Floor

605.14

-

208.86

... More
Forth Floor

605.14

-

214.15

... More
Fifth Floor

605.14

-

219.6

... More
50000023 "Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete. " (Ground Floor)

1863.6

-

58.32

... More
First Floor

2626.37

-

60.73

... More
Second Floor

2626.37

-

63.26

... More
Third Floor

2626.37

-

65.92

... More
Forth Floor

2626.37

-

68.71

... More
Fifth Floor

2626.37

-

71.64

... More
50000034 "Supplying ,fitting and fixing of M.S. grill,M.S levoured ventiletors including cost of labour,material,transportation etc. " (Ground Floor)

234.92

-

94.74

... More
First Floor

2656.82

-

94.74

... More
Second Floor

2656.82

-

94.74

... More
Third Floor

2656.82

-

94.74

... More
Forth Floor

2656.82

-

94.74

... More
Fifth Floor

2656.82

-

94.74

... More
50000039 "Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools and taxes etc. " (Ground Floor)

601.36

-

10008.82

... More
First Floor

199.99

-

10032.23

... More
Second Floor

199.99

-

10056.81

... More
Third Floor

199.99

-

10082.62

... More
Forth Floor

199.99

-

10109.72

... More
Fifth Floor

199.99

-

10138.17

... More
50000044 "Providing anti-termite treatment including labour and materials etc complete. " (Ground Floor)

429.23

-

35

... More
50000057 "Drip course mould plaster 1:4 (1:cement :4 sand) including necessary scaffolding curing etc complete at all depth and height as per direction of site in charge. " (Ground Floor)

115.3

-

9.66

... More
First Floor

285.95

-

10.06

... More
Second Floor

285.95

-

10.48

... More
Third Floor

285.95

-

10.92

... More
Forth Floor

285.95

-

11.38

... More
Fifth Floor

285.95

-

11.86

... More
50000059 "Supplying,fitting & fixing of 4""dia P.V.C. rain water pipe with necessary fittings and all complete. " (Ground Floor)

27.6

-

130.62

... More
First Floor

24

-

130.62

... More
Second Floor

24

-

130.62

... More
Third Floor

24

-

130.62

... More
Forth Floor

24

-

130.62

... More
Fifth Floor

24

-

130.62

... More
50000063 " One coat of priming with approved primer over new wood work. " (Ground Floor)

5.58

-

57.72

... More
First Floor

98.73

-

59.17

... More
Second Floor

98.73

-

60.66

... More
Third Floor

98.73

-

62.2

... More
Forth Floor

98.73

-

63.78

... More
Fifth Floor

98.73

-

65.41

... More
50000076 "Plinth protection with side brick masionary wall ( 1:6 ) inside sand filling over which 100 mm. thick dry rammed brick khoa packed & over that 50 mm. thick C.C ( 1:4 ) with cement plastering ( 1:4 ) in proper slope. " (Ground Floor)

45.75

-

1695.53

... More
50000488 "Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth" (Ground Floor)

37.22

-

4152.15

... More
50000490 "Fly Ash brick masonary in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete. In Superstructure. " (Ground Floor)

61.13

-

4185.15

... More
First Floor

97.87

-

4447.42

... More
Second Floor

97.87

-

4749.03

... More
Third Floor

97.87

-

5095.88

... More
Forth Floor

97.87

-

5494.76

... More
Fifth Floor

97.87

-

5953.47

... More
50000495 "Fly Ash brick masonary in cement mortar 1:4 (1 cement :4sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75 kg per sqcm with dimentional tolerance +/-8% including watering, curing and cost, coveyance, royalty of all materials and cost of labour etc complete. In Superstructure. " (Ground Floor)

9.38

-

4373.15

... More
First Floor

32.03

-

4635.42

... More
Second Floor

32.03

-

4937.03

... More
Third Floor

32.03

-

5283.88

... More
Forth Floor

32.03

-

5682.76

... More
Fifth Floor

32.03

-

6141.47

... More
50000542 Supplying and fitting, fixing of industrial paver tiles including cost of tile, material,labour T & P etc. (Ground Floor)

468.8

-

856.13

... More
50000802 Shifting of debrises upto 5km from site including loading and unloading. (Ground Floor)

78

-

397.48

... More
50000884 "Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. " (Ground Floor)

5.58

-

133.42

... More
First Floor

98.73

-

136.86

... More
Second Floor

98.73

-

140.4

... More
Third Floor

98.73

-

144.05

... More
Forth Floor

98.73

-

147.81

... More
Fifth Floor

98.73

-

151.68

... More
50000964 Fixing of Granite Flooring in floors, Treads ()(&()) Landings on 25mm thick bed of cement mortar 1:1 jointed with neat cement slury mixed with pigment to match the shades of the Granite including rubbing and polishing complete etc. (Ground Floor)

40.59

-

1793.16

... More
First Floor

50

-

1814.07

... More
Second Floor

50

-

1836.03

... More
Third Floor

50

-

1859.09

... More
Forth Floor

50

-

1883.3

... More
Fifth Floor

50

-

1908.72

... More
50001814 Providing & Fixing UPVC glazed sliding window with frames and shases shall be from white UPVC profile which shall have 3 hollow chambers from front to back depth of 65/118 mm. All section of frame and shases shall be reinforced with galvanized mild steel in single continious length,window shall be such that glazing or reglazing on site possible without the need to remove the outer frame from the structure of the building.The glazing must be used 5mm thick reflective glass complete in all respect as per the direction of the Engineer-In -Charge. (Ground Floor)

56.34

-

5357.14

... More
Second Floor

56.34

-

5357.14

... More
Third Floor

56.34

-

5357.14

... More
Forth Floor

56.34

-

5357.14

... More
Fifth Floor

56.34

-

5357.14

... More
50002518 Providing & Cutting bushes and leveling the grounding by back end loader (JCB), shifting the debaries 5 km from the site and as per the instruction of EIC. (Ground Floor)

20

-

730.43

... More
50004475 Providing & Fixing of ISI marked 30 mm thick Flush Door Shutters finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125x85x5.5), 2 Nos SS Tower Bolt(250x10), 1 No SS Aldrop (400 X 300), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials, adhesives etc complete. (Excluding door closure, ornamental handle & Mortice Lock). As per the direction of Engineer-in-Charge. (Green /KIT /Century) [NSWI] (Ground Floor)

13.86

-

6956.95

... More
First Floor

62.58

-

6956.95

... More
Second Floor

62.58

-

6956.95

... More
Third Floor

62.58

-

6956.95

... More
Forth Floor

62.58

-

6956.95

... More
Fifth Floor

62.58

-

6956.95

... More
50004496 Providing & Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units be of approved colour using high quality pigments complete in all respect as per specification and as per the direction of Engineer-in-Charge.(Century) [NSWI] (Ground Floor)

31.8

-

1682.96

... More
First Floor

203.8

-

1682.96

... More
Second Floor

203.8

-

1682.96

... More
Third Floor

203.8

-

1682.96

... More
Forth Floor

203.8

-

1682.96

... More
Fifth Floor

203.8

-

1682.96

... More
50004506 Providing & Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250x10), 1 No SS Aldrop (400 X 300), 4 Nos. SS Butt Hinges (125x8.5x5.5), Backside Buffer with all necessary fittings Complete with approved colour as per the direction of Engineer-in-Charge. (Century) [NSWI] (Ground Floor)

12.6

-

7035.06

... More
Second Floor

12.6

-

7035.06

... More
Third Floor

12.6

-

7035.06

... More
Forth Floor

12.6

-

7035.06

... More
Fifth Floor

12.6

-

7035.06

... More
50004526 Supplying, Fitting & Fixing of 10 mm thick Digital Glazed Vitrified Tile/Double charged full body vitrified tile in floor of size 600mm x 600mm of approved shade laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout (2mm) of approved quality including cost of all materials, labour T & P etc required for the works all complete as per direction of Engineer-in-Charge. (For new work only) (SOMANY/ KAJURIA/ NITCO / RAK/VARMORA) [NSWI] (Ground Floor)

90.81

-

1188.39

... More
First Floor

390.64

-

1198.08

... More
Second Floor

390.64

-

1208.25

... More
Third Floor

390.64

-

1218.93

... More
Forth Floor

390.64

-

1230.14

... More
Fifth Floor

390.64

-

1241.92

... More
50004546 Providing, Fixing & Fitting Anti-skid vitrified floor tiles of 9mm thick of size 300mm x 300mm laid over 25mm Cement mortar (1:1) laid in proper slope and filling joints with epoxy grout (2mm) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect as per the direction of the Engineer-in-charge. (SOMANY/ KAJARIA/ NITCO / RAK). [NSWI] (Ground Floor)

23.79

-

828.34

... More
Second Floor

23.79

-

838.51

... More
Third Floor

23.79

-

849.19

... More
Forth Floor

23.79

-

860.4

... More
Fifth Floor

23.79

-

872.18

... More
50004556 Providing, Fixing & Fitting Ceramic glazed tiles on wall of size 300mmx450mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect as directed by the Engineer-in-charge. (SOMANY/ KAJARIA/ NITCO / RAK) [NSWI] (Ground Floor)

134.58

-

905.51

... More
Second Floor

134.58

-

920.82

... More
Third Floor

134.58

-

936.89

... More
Forth Floor

134.58

-

953.76

... More
Fifth Floor

134.58

-

971.48

... More
50004566 Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. (ASIAN (ULTIMA) / BURGER (Anti Dust) / and DULUX (Weather Shield).[NSWI] (Ground Floor)

682.89

-

104.34

... More
First Floor

732.92

-

106.94

... More
Second Floor

732.92

-

109.67

... More
Third Floor

732.92

-

112.54

... More
Forth Floor

732.92

-

115.55

... More
Fifth Floor

732.92

-

118.71

... More
50004576 Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application.(ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). [NSWI] (Ground Floor)

1180.71

-

102.51

... More
First Floor

1893.45

-

104.07

... More
Second Floor

1893.45

-

105.68

... More
Third Floor

1893.45

-

107.34

... More
Forth Floor

1893.45

-

109.05

... More
Fifth Floor

1893.45

-

110.81

... More
50004586 Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. [NSWI] (Ground Floor)

223.18

-

511.19

... More
First Floor

486.18

-

511.19

... More
Second Floor

486.18

-

511.19

... More
Third Floor

486.18

-

511.19

... More
Forth Floor

486.18

-

511.19

... More
Fifth Floor

486.18

-

511.19

... More
50004636 Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.(N.S.W.I) (Ground Floor)

1180.71

-

99.31

... More
First Floor

1893.45

-

100.63

... More
Second Floor

1893.45

-

101.99

... More
Third Floor

1893.45

-

103.39

... More
Forth Floor

1893.45

-

104.83

... More
Fifth Floor

1893.45

-

106.31

... More
50004790 Providing and fixing Storage cabinet.(GODREJ 4 door Bookcase with Metal Top PLM Code-56101507SD00046/56/58).[NSWI] (Ground Floor)

4

-

27971

... More
Second Floor

4

-

27971

... More
Third Floor

4

-

27971

... More
Forth Floor

4

-

27971

... More
Fifth Floor

4

-

27971

... More
50005051 Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.5m. in depth and depositing the soil within initial lead of 50m. as per specification approved by the department. (Ground Floor)

262.44

-

1625.78

... More
INE

-

-

-

... More
40000946 PRecessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch /Angle holder-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

237

-

949.66

... More
40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-switch/ceiling rose-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

164

-

958.57

... More
40000952 Recessed wiring to Calling Bell Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular bell push ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-Bellpush-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

20

-

1100.41

... More
40000958 Recessed wiring to Television Point (Modular)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-switch/socket/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

40

-

1591.17

... More
40000961 Recessed wiring to Telephone Point (socket)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with socket ISI marked MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-switch/socket/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

20

-

927.32

... More
40000970 Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/ceiling rose-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

102

-

958.54

... More
40000973 Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/ceiling rose-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

60

-

958.54

... More
40000979 Recessed wiring to Security Light Point ( MODULAR) (4X24WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 15 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard/HPL) Make-switch/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

6

-

973.3

... More
40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/Socket-Legrand/ Wipro/ Anchor/ havells/ Panasonic) (Ground Floor)

242

-

526.12

... More
40000988 Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/Socket-Legrand/ Wipro/ Anchor/ havells/ Panasonic) (Ground Floor)

140

-

970.09

... More
40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) ( CSR SL .No- 1.8.2) (Ground Floor)

2490

-

140.02

... More
40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) ( CSR SL .No- 1.8.3) (Ground Floor)

1900

-

157.2

... More
40001012 Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) ( CSR SL .No- 1.8.10) (Ground Floor)

600

-

284.18

... More
40001051 Supply and laying of 150 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) (Ground Floor)

50

-

949.1

... More
40001123 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required( CSR Sl. No- 3.2, ) (Ground Floor)

2

-

2437.86

... More
40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) (Ground Floor)

240

-

26.89

... More
40001129 Supplying and fixing of 6"X4" 16/18 swg metal box of following size on surface / recesss with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5) (Ground Floor)

100

-

52.66

... More
40001132 Supplying and fixing of 8"X6" 16/18 swg metal box of following size on surface / recesss with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5) (Ground Floor)

80

-

74.93

... More
40001135 Supplying and fixing of 8"X10" 16/18 swg metal box of following size on surface / recesss with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5) (Ground Floor)

36

-

115.98

... More
40001141 Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421) (Ground Floor)

20

-

123.81

... More
40001145 Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421) (Ground Floor)

60

-

170.63

... More
40001148 Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421) (Ground Floor)

20

-

228.7

... More
40001151 Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421) (Ground Floor)

70

-

270.11

... More
40001154 Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421) (Ground Floor)

56

-

381.76

... More
40001172 Supply of U-type fan hook (Ground Floor)

102

-

89.7

... More
40001187 Supply and fixing of 8 way , Double Door MCB Box with 1 No 32 Amp. DP MCB & 6 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.6,2.7, )Make-MCB-(Legrand/L &T/ABB/SCHNIDER/ANCHOR-PANASONIC) (Ground Floor)

2

-

2753.18

... More
40001190 Supplying and fixing of Call Bell/buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required (CSR sl no-1.30) (Ground Floor)

20

-

119.63

... More
40001193 Blanking Plate (Ground Floor)

200

-

19.61

... More
40001228 Supply & fixing of 45 W LED STREET LIGHT FITTING on wall with , G.I. Bracket, Clamp & Nut Bolt connecting wire all accessories refer to catalouge No- MAKE- CROMPTON, CODE-LSTO-45-CDL /MAKE-PHILIPS, MODEL-GREEN LINE , CODE-BRP320 / MAKE-HPL, CODE-HPLLEDST4060S & HPLLEDSL4560S including fixing and connections as per instruction of Electrical Engineer-in-charge. (Ground Floor)

6

-

5037

... More
40001234 supply of Stepped type modular fan regulator (Ground Floor)

102

-

249.61

... More
40001295 Supply and fixing of 4 way mcb Box ( 4+12) with 63 amp 4P Isolator/ 4P MCB & 12 nos 20 amp SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required. Make-MCB-(Legrand/L&T/ABB/SCHNIDER/ANCHOR-PANASONIC) (Ground Floor)

20

-

4269.84

... More
40001583 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS/ WIPRO/HAVELLS/PANASONIC) (Ground Floor)

237

-

120.75

... More
40001586 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections as per instruction of Electrical Engineer-in-charge (Make- CROMPTON/ PHILIPS/ WIPRO/HAVELLS/PANASONIC) (Ground Floor)

164

-

758.99

... More
40001589 Supply and fixing of 1200 mm sweep AC ceiling fan with connecting wire and all accessories including hanging and connections as per instruction of Electrical Engineer-in-charge.- [MAKE- USHA/ CROMPTON/HAVELLS/ANCHOR-PANASONIC) (Ground Floor)

102

-

1874.17

... More
40001592 Supply and fixing of 300 mm sweep square shaped louvers exhaust fan with connecting wire and all accessories including fixing and connections as per instruction of Electrical Engineer-in-charge. [MAKE- USHA/ CROMPTON/HAVELLS/ANCHOR-PANASONIC) (Ground Floor)

60

-

2024

... More
40001876 Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion as per instruction of Electrical-Engi neer-in-Charge (Ground Floor)

40

-

80.5

... More
40001879 Recessed wiring in 1X1.5sqmm (For inverter)FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/L &T/Anchor/Havels/V guard) (Ground Floor)

1245

-

105.87

... More
40002785 SUPPLY AND FIXING OF FLOOR / WALL MOUNTED MAIN PANNEL BOARD MADE OUT OF 1.6MM C.R.C.A. SHEET DULY POWDER COATED HAVING FOLLOWING ARRANGEMENTS. [DULY WIRED WITH SOCKETING] ALL MAIN SWITCHES – (SIMENS / L&T / HPL /ABB ) ALL MCB – Legrand/L&T/ABB/SCHNIDER/ANCHOR-PANASONIC ALL CUT OUT – ANCHOR /BPC MAKE ALL WIRINGS – FINOLEX / RR/POLYCAB SIZE OF COPPER BUS BAR - AS PER RATING OF INCOMING MAIN SWITCH WITH COPPER NUT BOLT NEUTRAL LINK – AS PER MAIN SWITCH CURRENT RATING VOLTMETER & AMMETER – AE / CAPPA INDICATOR – LED SELECTOR SWITCH – SALZAR / SURDHI BUS BAR INSULATOR – RESIN CAST DRUM INSULATOR BUS BAR CHAMBER MUST BE COVERED WITH 3 MM THICK BAKELITE COVER[NATIONAL / ROYALAM]( AS PER ENCLOSED DRAWING) 1 Set : LED type R-Y-B phase indicating lamps with control fuses. COMMON SERVICE PANEL 1 No 125 A, 4P onload change over switch 1 No 100 A,35 KA, TP MCCB Out Going Busbar- 4 Nos 150A, 500V Electrolytic copper strips 63 Amp 4P MCB-2 Nos 40 Amp 4P MCB-2 Nos 63 Amp DP MCB-3 Nos 32 Amp DP MCB-3 Nos Instruments 1 No of 0-100A amperemeter with CTS with selector switch 1 No of 0-500V voltmeter with selector switch 1 Set : LED type R-Y-B phase indicating lamps with control fuses. (Ground Floor)

1

-

69791.63

... More
40002791 Supply and fixing of Cable Tray 12 inch including all accessories and connections as per instruction of Electrical Engineer-in- Charge (Ground Floor)

80

-

621

... More
40002864 SUPPLY AND FIXING OF FLOOR / WALL MOUNTED MAIN PANNEL BOARD MADE OUT OF 1.6MM C.R.C.A. SHEET DULY POWDER COATED HAVING FOLLOWING ARRANGEMENTS. [DULY WIRED WITH SOCKETING] ALL MAIN SWITCHES – (SIMENS / L&T / HPL /ABB ) ALL MCB – Legrand/L&T/ABB/SCHNIDER/ANCHOR-PANASONIC ALL CUT OUT – ANCHOR /BPC MAKE ALL WIRINGS – FINOLEX / RR/POLYCAB SIZE OF COPPER BUS BAR - AS PER RATING OF INCOMING MAIN SWITCH WITH COPPER NUT BOLT NEUTRAL LINK – AS PER MAIN SWITCH CURRENT RATING VOLTMETER & AMMETER – AE / CAPPA INDICATOR – LED SELECTOR SWITCH – SALZAR / SURDHI BUS BAR INSULATOR – RESIN CAST DRUM INSULATOR BUS BAR CHAMBER MUST BE COVERED WITH 3 MM THICK BAKELITE COVER[NATIONAL / ROYALAM]( AS PER ENCLOSED DRAWING) MAIN DISTRIBUTION BOARD 1 No 630 A, 50 KA, FP MCCB with Micro Processor Release Out Going Busbar- 4 Nos 800A, 500V Electrolytic copper strips Arrangement of 34 compartments for installation of 30Nos 1- ph energy meter & 4 Nos of 3 ph energy meter alongwith 30 Nos 63 Amp 4PMCB & 4 Nos of 100 Amp MCCB & Locking Arrangement individually. Instruments Nos multifunction meters showing voltage, current, pf , frequency, MD & THD with required 800/5A CTs 1 Set : LED type R-Y-B phase indicating lamps with control fuses. (Ground Floor)

1

-

365130.75

... More
IPH

-

-

-

... More
10000000 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 15mm nominal outer dia pipes (Ground Floor)

170

-

171.12

... More
10000002 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 20mm nominal outer dia pipes (Ground Floor)

260

-

223.48

... More
10000004 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 25mm nominal outer dia pipes (Ground Floor)

70

-

300.63

... More
10000006 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 40mm nominal outer dia pipes (Ground Floor)

140

-

584.65

... More
10000008 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 50mm nominal outer dia pipes (Ground Floor)

328

-

896.78

... More
10000020 Providing and fixing on wall face unplasticised Rigid PVC soil,waste and rain water pipes conforming to IS : 13592 Type A,including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion, (i)single socket pipes. For 110mm diameter U-PVC SWR pipes. (Ground Floor)

280

-

346.68

... More
10000164 Extra over item Water Tank for hoisting Rotational moulded polyethylene cylindrical vertical water storage tanks of the following size for every additional height of 5 metres or part thereof (Hoisting Charges). (Ground Floor)

105

-

165.31

... More
10000172 Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately). (200mm dia rigid UPVC pipe Class- 3 (0.60 mpa)). (Ground Floor)

85

-

942.37

... More
10000180 Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to JAQUAR MAKE of brand code(CNS-WHT-755SS and CNS-WHT-207) including automatic flushing systern of viteros china make and seat cover fixing to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification.(Bowl for couple closet -WC with soft closing seat cover size:360x680x775,Strap-220mm,cistern with cistern fittings for 755 SS). (Ground Floor)

40

-

8092.98

... More
10000186 Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-2004 / JAQUAR MAKE with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification.(Vitreous china flat back wash basin 550x400x200 mm)(CODE CNS-WHT-801) with(CNS-WHT-301 FULL PEDESTAL) (JAQUAR MAKE). (Ground Floor)

60

-

6392.97

... More
10000194 Fixing of Screw-down TWO WAY Bib Cocks (Taps) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Head & high quality),(15mm diameter Two way short body bib cock (CODE CON-041KN). (Ground Floor)

40

-

1379.81

... More
10000198 Fixing of Screw-down SHORT BODY Bib Cocks (Taps) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Head & high quality)(15mm diameter short body bib cock(CODE CON-037KN). (Ground Floor)

60

-

843.79

... More
10000200 Fixing of Screw-down SINK Cocks (Taps) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Head& high quality),(15mm diameter Sink Cock (CODE CON-347KN). (Ground Floor)

20

-

1915.83

... More
10000206 Fixing Chromium Plated Shower rose conforming OHS-1985 (JAQUAR MAKE)including polishing all complete as per specification.(Deluxe Head &Heavy quality). (Ground Floor)

40

-

1133.22

... More
10000208 Fixing Chromium Plated Arm of 15mm or 20mm inlet conforming to (Shower Arm Casted 190mm Long Light Body Round Shape for Wall mounted Showers with flange, SHA-477) (JAQUAR MAKE)including polishing all complete as per specification.(Deluxe Head &Heavy quality). (Ground Floor)

40

-

694.65

... More
10000210 Fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of the following nominal bore as per specification( Fixing of CP wall mixture conforming to CON-219KN) ( JAQUAR MAKE). (Ground Floor)

40

-

3719.66

... More
10000212 Fitting,Fixing of Health faucet conforming to(Hand Shower (Health faucet) ABS Body with 8mm Dia 1.2 Meter Long Flexible Tube & Wall Hook, ALD-CHR-593-N),( JAQUAR MAKE) including all complete as per specification.(Chrome Finish) (Ground Floor)

40

-

1279.4

... More
10000216 Fixing Chromium Plated soap dish Holder complete with Chromium Plated brass brackets fixed to P.V.C plugs with Chromium Plated brass screws as per specification.(JAQUAR MAKE,BRAND ACN-1131N). (Ground Floor)

60

-

928.77

... More
10000218 Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification.(600mm Long glass shelf (JAQUAR MAKE BRAND ACN-1171N), (Ground Floor)

40

-

1484.87

... More
10000222 Fixing standard sized towel rail of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.(Single towel rail 600mm long),( BRAND CODE ACN-1111NM),(Heavy quality). (Ground Floor)

40

-

1553.2

... More
10000224 Fixing standard sized towel ring of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.(Towel Ring Round With Round Flange (BRAND CODE ACN-1121BN). (Ground Floor)

60

-

960.6

... More
10000230 Fixing standard size Chromium Plated Toilet paper holder fixed to woden plugs with Chromium Plated brass screws complete as per spec ification.(Toilet Roller Holder ACN-1151N,JAQUAR Make).with all fittings. (Ground Floor)

40

-

880.24

... More
10000298 Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110MM DIA PLAIN BEND P.V.C SWR TYPE (Ground Floor)

4

-

166.02

... More
10000300 Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110mm dia bend with door P.V.C SWR TYPE (Ground Floor)

100

-

199.04

... More
10000304 Fixing 110mm size ‘P’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification.110 MM DIA P.V.C SWR P-TRAP (Ground Floor)

80

-

306.72

... More
10000308 Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification.110mm dia GULLY Trap P.V.C SWR TYPE (Ground Floor)

32

-

482.77

... More
10000334 Providing and fixing Stainless Steel kitchen sink with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.40"X20"X10" STEEL sink single bowl with drain board (PARRY WARE) as per the direction of the E.I.C . (Ground Floor)

20

-

8824.78

... More
10000338 Fixing of U.P.V.C Ball Valve of 50mm diameter conforming to the following nominal sizes with wheel as per specification complete .(S olvent Welded With Metal Ball) As per the direction of the E.I.C . (Ground Floor)

2

-

2413.32

... More
10000344 Fixing of U.P.V.C Ball Valve of 20mm diameter conforming to the following nominal sizes with wheel as per specification complete .(S olvent Welded With Metal Ball) As per the direction of the E.I.C . (Ground Floor)

85

-

404.28

... More
10000352 Fixing of C.P Screw-down Stop Cocks conforming to of the following nominal sizes as per specification complete. (Deluxe Head& high quality),15mm diameter angular stop cock ( ANALYSIS DONE AS PER AR-2013 SL NO-3.2.16 (Ground Floor)

80

-

850.57

... More
10000376 Fixing Frammed mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification.AR.-2013,SL.-NO-3.4.26. (Ground Floor)

60

-

719.21

... More
10000704 Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the E.I.C .3Layer Cylinderical Vertical water storage tanks (Details of cost for one Tank On the roof of ground floor) (Ground Floor)

28000

-

12.3

... More
10000708 Supply fitting fixing of side jally at required places where water drainage are provided as per the direction & instruction of the E.I.C . (Ground Floor)

80

-

150

... More
MIS-CVL-DRAIN

-

-

-

... More
50000001 "Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014cum in volume within 50 m.initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5cm. to 7cm. and laying in layers not exceeding 0.3m. depth. " (Ground Floor)

70.75

-

291.5

... More
50000003 "Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc.complete all depth and height. " (Ground Floor)

9.43

-

3924.35

... More
50000008 "Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. " (Ground Floor)

32.57

-

4398.8

... More
50000009 "Rigid and smooth centering and shuttering false, levelled works and dismentalling then after casting including cost of mterials complete for Plinth band & Column Footing. " (Ground Floor)

260.12

-

103.22

... More
50000013 "Providing and fixing,centering,shuttering of R.C.C. slabs, staircase,Chajja,including removal of form work at all depth and height. " (Ground Floor)

80.51

-

422.1

... More
50000017 "Supplying of filling sand in foundation and plinth including watering,ramming,consolidating and dressing,labours,tools, taxes etc., all complete as per the specification and direction of E.I.C. " (Ground Floor)

7.08

-

464.94

... More
50000039 "Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools and taxes etc. " (Ground Floor)

23

-

10008.82

... More
MIS-CVL-EXTERNAL P

-

-

-

... More
50003066 "Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of ownrigs with its accessories, tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Labour for drilling) ,(REVISED). " (Ground Floor)

480

-

621.23

... More
50003068 Cost of P.V.C (A S T M SCHEDULE-80) pipe 200 mm dia (ASTM D-1785) Make-Oriplast, Hariplast.(REVISED) (Ground Floor)

240

-

1406.6

... More
50003070 "Lowering the 200mm dia size PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position,including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials,tools and plant etc.complete and keeping the top of the casing pipe threaded including plugging tubewells to prevent entry of foreign materials from above.(REVISED) " (Ground Floor)

300

-

127.7

... More
50003072 "Cleaning and developing the 200mm dia tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Char ge.(REVISED) " (Ground Floor)

4

-

4847.25

... More
50003076 Submersible Pump Set with the cost of Motor 1.5HP Single phase(32 Mtr. Head) Model (GP121507),(REVISED) (Ground Floor)

4

-

11298.75

... More
50003082 Control Panel Board (C&S) Upto 3HP Single Phase.(REVISED) (Ground Floor)

4

-

2925

... More
50003086 HDPE Pipes 32/40 mm ( High Density PVC pipes inner dia 32mm, outer dia 40mm, 6Kg/ Cm Sqr. With IS specification (Detail cost per 1 meter)(REVISED) (Ground Floor)

560

-

90.33

... More
50003088 Steel Rope with PVC coated 6mm Detail cost per 1 meter.(REVISED) (Ground Floor)

560

-

26.7

... More
50003090 Finolex/L&T/BCH Cable 4 Sq. mm( 3core copper wire flat cablePVC insulation) Detail cost per 1 meter.(REVISED) (Ground Floor)

600

-

112.98

... More
50003092 Accessories like Nipple, Bore cover,MS clamp, Nut Bolt,Stainless steel nipple, Short piece, GI bend, Socket etc. complete.Detail cost per 1 Set.(REVISED) (Ground Floor)

4

-

961.54

... More
50003094 Bore Well Installation Charges including transportation Charge per 1 Set.(REVISED). (Ground Floor)

4

-

4200

... More
MIS-CVL-FIRE ALARM

-

-

-

... More
50005814 Supply Installation Testing Commissioning of 8 zone conventional / Micro process based fire alarm control panel with suitable fittings, battery charger etc. .Make- Honey well / Agni)(FIRE ALARM SYSTEM) (Ground Floor)

1

-

24500

... More
50005816 Supply Installation Testing Commissioning of electronic hooter Make (Agni) (Ground Floor)

8

-

1150

... More
50005818 Supply Installation Testing Commissioning of manual call point Make ( Agni) .(FIRE ALARM SYSTEM) (Ground Floor)

8

-

850

... More
50005820 Supply Installation Testing Commissioning of 2X1.5 sq mm copper cable wiring with PVC conduit and suitable clamps, fittings etc . (FIRE ALARM SYSTEM) (Ground Floor)

130

-

95

... More
50005822 Supply Installation Testing Commissioning of 7 a.h 12 volt 2 nos. battery .(FIRE ALARM SYSTEM) (Ground Floor)

2

-

1000

... More
MIS-CVL-FIRE EXTIN

-

-

-

... More
50005824 Supply of 4.5 Kg capacity ISI Marked Co2 type Fire Extinguisher confirming to IS15683 with fire rating made from seamless cylinder conforming to IS : 7285 duly approved by Chief Controller of Explosive, Nagpur, fitted with ISI marked Controlled Valve confirming to IS : 3224, high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket. (Make Fire shield / life guard) etc.(FIRE EXTINGUISHER) (Ground Floor)

2

-

5900

... More
50005826 Supply of 6 Kg capacity Fire Shield brand ABC Stored Pressure type Fire Extinguisher consisting of wielded cylinder, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket, conforming to IS : 13849 duly charged with ISI Marked Mono Ammonium Phosphate base ABC Powder conforming to IS : 14609 and pressurized with Nitrogen Gas (ISI Marked) Make Fire shield / life guard etc. (Ground Floor)

16

-

3000

... More
50005828 Supply of 9 ltr capacity Fire Shield brand water Co2 store Pressure type Fire Extinguisher consisting of wielded cylinder, squeeze lever discharge valve fitted with pressure indicating gauge, internal discharge tube, discharge nozzle suspension bracket, conforming to IS : 13849 duly charged with Co2 gas with water (ISI Marked) Make Fire shield / life guard etc. (FIRE EXTINGUISHER) (Ground Floor)

8

-

3000

... More
MIS-CVL-FIRE FIGHT

-

-

-

... More
50005770 Supply Installation Testing Commissioning of 100mm MS Pipe confirming to IS 1239 heavy grade with painting, welding & fittings with suitable support etc.(Jindal/TATA) (FOR FIRE FIGHTING SYSYTEM) (Ground Floor)

65

-

1725

... More
50005772 Supply Installation Testing Commissioning of 80mm MS Pipe confirming to IS 1239 heavy grade with painting, welding & fittings with suitable support etc.(Jindal/TATA) (FIRE FIGHTING SYSTEM) (Ground Floor)

3

-

1150

... More
50005774 Supply Installation Testing Commissioning of 50mm MS Pipe confirming to IS 1239 heavy grade with painting, welding & fittings with suitable support etc.(Jindal/TATA) (FIRE FIGHTING SYSTEM) (Ground Floor)

3

-

750

... More
50005776 Supply Installation Testing Commissioning of 25mm MS Pipe confirming to IS 1239 heavy grade with painting, welding & fittings with suitable support etc.(Jindal/TATA) (FIRE FIGHTING SYSTEM) (Ground Floor)

2

-

575

... More
50005778 Supply Installation Testing Commissioning of 19mm dia 30mtr length rubberized swing / fast aid hose real, shut up nozzle with suitable fittings & clamb etc. (Attasi/Newage) (FIRE FIGHTING SYSTEM) (Ground Floor)

8

-

6800

... More
50005780 Supply Installation Testing Commissioning of fire brigade inlet point with suitable fittings etc. (FIRE FIGHTING SYSYTEM) (Ground Floor)

1

-

6500

... More
50005782 Supply Installation Testing Commissioning of ISI mark 100mm CI Butter fly valve (PN16) standard liver operated type double flange with nut bolt etc. (FIRE FIGHTING SYSTEM) (Ground Floor)

3

-

5850

... More
50005784 Supply Installation Testing Commissioning of ISI mark 100mm CI Non return valve (PN16) double flange with nut bolt etc.(FIRE FIGHTING SYSTEM) (Ground Floor)

2

-

5900

... More
50005786 Supply Installation Testing Commissioning of 900 LPM fire pump with suitable base frame made by angle support with tie rod bullet painting with complete fitting (Make Texmo/Kilosker).(FIRE FIGHTING SYSYTEM) (Ground Floor)

1

-

45500

... More
50005788 Supply Installation Testing Commissioning of Tanki nipple .(FIRE FIGHTING SYSTEM) (Ground Floor)

15

-

1050

... More
50005790 Supply Installation Testing Commissioning of Fire hydrant automatic Control pannel for auto system aliening with pressure switch and pressure gauge. (FIRE FIGHTING SYSTEM) (Ground Floor)

1

-

24500

... More
50005792 Supply Installation Testing Commissioning of Night vision exit signage with different required version.(FIRE FIGHTING SYSTEM) (Ground Floor)

40

-

550

... More
50005794 Supply Installation Testing Commissioning of 25mm high pressure bulb valve with suitable short peace pipe tapeline tape with required fittings etc. (FIRE FIGHTING SYSTEM) (Ground Floor)

9

-

1150

... More
50005796 Supply Installation Testing Commissioning of Spring loaded GM Air realize valve with suitable short peace pipe tapeline tape with required fittings etc . (FIRE FIGHTING SYSYTEM) (Ground Floor)

1

-

3550

... More
50005798 Supply Installation Testing Commissioning of 100mm elbo flange, 80mm elbo, flange nut bolt gaskets, angle bullet etc. (FIRE FIGHTING SYSTEM) (Ground Floor)

1

-

45000

... More
50005800 Supply Installation Testing Commissioning of 63mm SS landing valve with gas ket, nut bolt, welding, fitting, painting with required equipments etc. (FIRE FIGHTING SYSTEM) (Ground Floor)

8

-

5950

... More
50005802 Supply Installation Testing Commissioning of double door MS hose box with anker fast bolt , nut bolt, welding, fitting, painting with required equipments etc.(FIRE FIGHTING SYSTEM) (Ground Floor)

8

-

4650

... More
50005804 Supply Installation Testing Commissioning of 63mm Canvas hosepipe 15mtr length X 2 nos etc. (FIRE FIGHTING SYSTEM). (Ground Floor)

16

-

4650

... More
50005806 Supply Installation Testing Commissioning of Branch pipe .(FIRE FIGHTING SYSYTEM) (Ground Floor)

8

-

1850

... More
50005808 Supply Installation Testing Commissioning of 10 sqmm X 3 core aluminum armoured cable for connection from panel to fire pump with required suitable fitting for connection .(FIRE FIGHTING SYSTEM) (Ground Floor)

45

-

165

... More
50005810 Supply Installation Testing Commissioning of pressure switch for automation of the fire pump with cable & required fittings et c.(FIRE FIGHTING SYSTEM) (Ground Floor)

1

-

3200

... More
50005812 Supply Installation Testing Commissioning of pressure gauge for automation of the fire pump with cable & required fittings etc .(FIRE FIGHTING SYSTEM) (Ground Floor)

1

-

2250

... More
MIS-CVL-INISPECTIO

-

-

-

... More
50000001 "Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014cum in volume within 50 m.initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5cm. to 7cm. and laying in layers not exceeding 0.3m. depth. " (Ground Floor)

73.79

-

291.5

... More
50000003 "Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc.complete all depth and height. " (Ground Floor)

8.2

-

3924.35

... More
50000008 "Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. " (Ground Floor)

11.38

-

4398.8

... More
50000009 "Rigid and smooth centering and shuttering false, levelled works and dismentalling then after casting including cost of mterials complete for Plinth band & Column Footing. " (Ground Floor)

11.46

-

103.22

... More
50000017 "Supplying of filling sand in foundation and plinth including watering,ramming,consolidating and dressing,labours,tools, taxes etc., all complete as per the specification and direction of E.I.C. " (Ground Floor)

8.2

-

464.94

... More
50000022 "16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand)including necessary scaffolding curring etc. all complete at all depth and height. " (Ground Floor)

37.37

-

193.89

... More
50000039 "Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools and taxes etc. " (Ground Floor)

5.43

-

10008.82

... More
50000488 "Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth" (Ground Floor)

34.46

-

4152.15

... More
50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. (Ground Floor)

160.37

-

153.11

... More
MIS-CVL-PAVER ROAD

-

-

-

... More
50000001 "Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014cum in volume within 50 m.initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5cm. to 7cm. and laying in layers not exceeding 0.3m. depth. " (Ground Floor)

336.06

-

291.5

... More
50000003 "Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc.complete all depth and height. " (Ground Floor)

8.84

-

3924.35

... More
50000008 "Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. " (Ground Floor)

2.36

-

4398.8

... More
50000017 "Supplying of filling sand in foundation and plinth including watering,ramming,consolidating and dressing,labours,tools, taxes etc., all complete as per the specification and direction of E.I.C. " (Ground Floor)

291.84

-

464.94

... More
50000020 "12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curring etc. All complete at all depth and height. for out side portion wall. " (Ground Floor)

193.54

-

135.67

... More
50000488 "Fly Ash brick masonary in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials & cost of labour etc complete. In Foundation & Plinth" (Ground Floor)

29.48

-

4152.15

... More
50001703 Providing and laying 60 mm thick Factory made cement concrete interlocking Paver block of M30 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge. (Ground Floor)

929

-

651.36

... More
MIS-CVL-SEWAGE TRE

-

-

-

... More
50005157 Supply, installation, testing & commissioning of 1 Nos Stainless Steel Perforated,Corrugated Bar Screen with suitable lifting arrangement (size 500 mm x 1000 mm). (Ground Floor)

1

-

17000

... More
50005163 Supplying, installing, testing and commissioning, consisting fine bubble diffuser along with membrane of SILICON membranes, PVC support pipe(10 ksc pressure rating),PVC fitting, nylon rope braided hose with all accessories to make it retrievable & to provide clog-free oxygen for Aeration Tanks. (Ground Floor)

12

-

2750

... More
50005167 Supply, installation, testing and commissioning of on line electronic sodium hypo chloride dosing sytem dosing pump and Tank etc., The unit shall comprise of the following: Capacity of the dosing Pump - 0-4 LPH Pressure- 4 Kg/cm2 Stroke per minute-55 Dosing Tank- 100 Ltr, Make- E-DOSE/PRO AQUA/KANAKDHARA (Ground Floor)

1

-

15000

... More
50005175 Supply, Installation, Testing Commisioning of pipes & Valves with fittings such as tees, crosses, plugs, sockets, elbows, unions, flanges, sleeve pieces, check nuts etc for the entire STP Plant. Inter connecting pipe works with valves for air line- JINDAL/TATA Inter connecting pipe works with valves for water line- UPC/UPVC-SUPREME/FINOLEX (Ground Floor)

1

-

70000

... More
50005177 supply, Installation , Testing Commisioning of of MCC Panel (motor control center) to accommodate all the drive units with cabling,glanding within the STP Compartmental , design Indoor wall mounted type with top entry for cable the internal components either Siemen / GE Shall be provided with 1 No. Energy meter. along with cable & Cable tray To receive, control and distribute electrical power at 440 V, 50 Hz, MCC is to be manufactured/assembled as per the latest ISI specification, Indian Electricity Rules, Including special requirements of concerned state electricity inspectorate.The switch board shall be fabricated out of 14 SWG sheet steel and shall be un cubical design.MCC of suitable rating to take care of full load of the sewage treatment plant including all motors and lighting.MCC shall be provided with the following feeders: Incoming Feeder :electronic digital energy meter suitable for full load Voltmeter with selector switch protected through HRC fuses ranging from 0 - 500 V. LED type indication for 3 phases, protected through HRC fuses.Outgoing Feeder :Motor feeder, 1 no. 3 phase and neutral MCCB of suitable capacity to be provided for lighting requirement of STP.Power Cables (LT) for use on 415 V system shall be of 1100 volt grade, Aluminium conductor, PVC insulated as per IS : 1554 (Part I). Motor upto 5 HP copper conductor cable should not be less than 2.5 sq mm of size to be used. (Ground Floor)

1

-

75000

... More
50005179 Commsioning of STP with consumables,Tools & tackles and manpower for 15 days.Test reports for both inlet and outlet in approved lab. (Ground Floor)

1

-

40000

... More
50005181 Supply, installation, testing & commissioning of non clogging sludge transfer pumps with all accessories, motor of required capacity, Pressure gauge on delivery line with control the level of EQT automatically. Pumps shall have following duty: Capcity - 1.0m3/Hr. Head - 10 mwc Motor HP/RPM- 0.5/2900 Make- KIRLOSKAR/LUBI/CG Quantity- 2 Nos (1w + 1 S) (Ground Floor)

1

-

15000

... More
50005185 Supply, installation, testing & commissioning of non clogging sewage transfer pumps with all accessories, motor of required capacity, Pressure gauge on delivery line with control the level of EQT automatically. Pumps shall have following duty: Capcity - 4.5 m3/Hr. Head - 10 mwc Motor HP/RPM- 1.0/2900 Make- KIRLOSKAR/LUBI/WILO Quantity- 2 Nos (1w + 1 S) (Ground Floor)

2

-

17500

... More
50005187 "Supplying, installing, testing and commissioning of Twin Lobe design type air blower complete with motors, pulleys, one piece CI casing and side plates, silencer, base plate, Anti-friction bearings, Rotary oil sealings having horizontal configuration.with electric motor "Capacity of Blower- 50 m3/Hr. Head- 0.4 kg/cm2 Motor HP/RPM- 3/1500 Make- A1/AKASH/AIRVAK MOC- CI Air Required for reactor tank- 39Nm3/Hr. Air Required for Equalization tank- 11Nm3/Hr. (Ground Floor)

2

-

110000

... More
50005189 Design Supply, installation, testing and commissioning of MBBR media, and Tube settler to be provided in the areation tank and settling tank. MOC of MBBR Media - Poly Propylene ,Make-COOLDECK/MM AQUA Quanity of FMR Media - 3.0 m3 Tube settler - 4.0 m3 (Ground Floor)

1

-

115000

... More
50005191 Supplying, installing, testing and commissioning Consisting of 2 Nos. of centrifugal filter feed pumps (one working + one standby) to feed the treated sewage Water from clarified water tank to Multigrade Filter & Activated Carbon Filter . Flow -4.5 m3/Hr. Head - 30 Mtr. Motor HP/RPM- 1.0/2900 Make- KIRLOSKAR/LUBI/WILO MOC- CI Quantity- 2 Nos (Ground Floor)

2

-

17500

... More
50005193 Supplying, installing, testing and commissioning of FRP composite Multigrade Filter with Multiport vales. Filter shall be suitable for working pressure of 3.5 kg / cm2 and shall include standard fittings like pressure gauges, sampling cock, etc. Flow Rate- 4.5m3/Hr. Dia x HoS ( mm )- MGF 21 x 62 MOC- FRP COMPOSITE VESSEL Make-TECHLITE/AQUANOMICS/STARLITE (Ground Floor)

1

-

80000

... More
50005195 Supplying, installing, testing and commissioning of FRP composite Activated Carbon Filter with five Multiport vales . Filter shall be suitable for working pressure of 3.5 kg / cm2 and shall include standard fittings like pressure gauges, sampling cock, etc. Flow Rate-4.5m3/Hr. Dia x HoS ( mm)- ACF 21 x 72 MOC- FRP COMPOSITE VESSEL Make- PENTAIR/AQUANOMICS/STARLITE (Ground Floor)

1

-

100000

... More
MIS-CVL-STP BASE

-

-

-

... More
50000001 "Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014cum in volume within 50 m.initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5cm. to 7cm. and laying in layers not exceeding 0.3m. depth. " (Ground Floor)

111.54

-

291.5

... More
50000003 "Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc.complete all depth and height. " (Ground Floor)

2.86

-

3924.35

... More
50000008 "Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. " (Ground Floor)

39.32

-

4398.8

... More
50000009 "Rigid and smooth centering and shuttering false, levelled works and dismentalling then after casting including cost of mterials complete for Plinth band & Column Footing. " (Ground Floor)

247.48

-

103.22

... More
50000011 "Providing and fixing,centering,shuttering of griders beams,column etc including removal of forms work at all depth and heaight. " (Ground Floor)

23.69

-

724.08

... More
50000013 "Providing and fixing,centering,shuttering of R.C.C. slabs, staircase,Chajja,including removal of form work at all depth and height. " (Ground Floor)

45.16

-

422.1

... More
50000017 "Supplying of filling sand in foundation and plinth including watering,ramming,consolidating and dressing,labours,tools, taxes etc., all complete as per the specification and direction of E.I.C. " (Ground Floor)

4.29

-

464.94

... More
50000019 "25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. " (Ground Floor)

22.58

-

292.9

... More
50000020 "12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curring etc. All complete at all depth and height. for out side portion wall. " (Ground Floor)

71.7

-

135.67

... More
50000021 "6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smmoth including closed deep chiping and slurry treatment with necessary scaffolding,curring etc. All complete at all depth and height.for inside and out side portion. " (Ground Floor)

35.62

-

151.36

... More
50000022 "16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand)including necessary scaffolding curring etc. all complete at all depth and height. " (Ground Floor)

65.19

-

193.89

... More
50000023 "Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete. " (Ground Floor)

172.5

-

58.32

... More
50000034 "Supplying ,fitting and fixing of M.S. grill,M.S levoured ventiletors including cost of labour,material,transportation etc. " (Ground Floor)

175

-

94.74

... More
50000039 "Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools and taxes etc. " (Ground Floor)

49.7

-

10008.82

... More
50000040 Distempering two coats to walls with distemper of approved shade including cost of all materials, labours,brushess etc.complete. (Ground Floor)

100.8

-

64.99

... More
50000063 " One coat of priming with approved primer over new wood work. " (Ground Floor)

3.25

-

57.72

... More
50000071 "2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard grinite chips on new work including cost of labour,material,T&P etc all complete. " (Ground Floor)

22.58

-

280.83

... More
50000490 "Fly Ash brick masonary in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete. In Superstructure. " (Ground Floor)

15.73

-

4185.15

... More
50000884 "Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. " (Ground Floor)

3.25

-

133.42

... More
50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. (Ground Floor)

171.43

-

153.11

... More
50004566 Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. (ASIAN (ULTIMA) / BURGER (Anti Dust) / and DULUX (Weather Shield).[NSWI] (Ground Floor)

71.7

-

104.34

... More
MIS-INE-ELEVATOR

-

-

-

... More
40000955 Recessed wiring to Bulk Head Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard) (Make-switch/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

28

-

966.13

... More
40000985 Point wiring for 5/ 6 amp socket outlet ( Separate) ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/Socket-Legrand/ Wipro/ Anchor/ havells/ Panasonic) (Ground Floor)

28

-

718.43

... More
40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) (CSR SL .No- 1.8.2) (Ground Floor)

180

-

140.02

... More
40001015 Recessed wiring to submain in 4 x 10 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 4 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) (CSR SL .No- 1.8.11) (Ground Floor)

40

-

410.42

... More
40001123 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required (CSR Sl. No- 3.2 ) (Ground Floor)

4

-

2437.86

... More
40001126 providing and fixing 8 SWG (4mm) dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) (Ground Floor)

280

-

26.89

... More
40001166 Supply and fixing of 63 AMP 4P MCB-1NO,63 AMP,415 V CUTOUT-3 NOS WITH COPPER BUS BAR & INDICATOR ETC including all accessories and connections As per instruction of electrical engineer -in-charge [Make-(a) MCB/MCCB- Legrand/ L&T/ ABB/ SCHNIDER/ ANCHOR-PANASONIC(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK] (Ground Floor)

2

-

18572.5

... More
40001367 Supply and laying of 16 sq.mm 4 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required.(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) (Ground Floor)

100

-

295.34

... More
40001595 Supply and fixing of Bulk Head fitting with 9 wt. LED Bulb including all accessories and connections as per instruction of Electrical Engineer-in-charge. (Make- CROMPTON/ PHILIPS/ WIPRO/HAVELLS/PANASONIC) (Ground Floor)

28

-

887.8

... More
40002155 Supply and fixing of 16 sq.mm 04 core PVC Al. Arm Cableof 1.1 KV grade end termination. (Ground Floor)

4

-

213.34

... More
40003153 Supply, Erection, Testing &Commissioning of 08 Passenger, (Ground + 7) floor Machine Room Elevator with ACV3F drive/control for constant load of 544 Kg.,eight stops , Automatic Rescue Device, Speed (01Meter per second), push button operation (Nudging), cross flow fan for ventilation, Auto fan cut off, heavy duty vinyl tile flooring, auto central door opening/closing ( All opening on same side), car position indicators, LED scrolling display, LED ceiling lights, auto voice synthesizer, overload alarming device, infrared door closing protection, door time protection, sensor based door movement, emergency alarming system, emergency light, braille push buttons, intercom, stainless steel mirror finished (lift car, lift door & hand rail), Fire rated door with 60 Mins. fire rating, Fireman's switch, Cladding at each stop(both side & top of each entrance with ply & lamination). The Elevator should be suitable for physically challenged persons.The scope of work is Supply, Erection, Testing & Commissioning of Elevator along with all related civil and electrification work. Make of the Elevator :- OTIS/MITSUBISHI/SCHINDLER/TKE ( THYSENKRRUP) (Ground Floor)

1

-

1508475

... More
40003155 Supply, Erection, Testing &Commissioning of 13 Passenger, (Ground + 7) floor Machine Room Elevator with ACV3F drive/control for constant load of 884 Kg.,eight stops , Automatic Rescue Device, Speed (01Meter per second), push button operation (Nudging), cross flow fan for ventilation, Auto fan cut off, heavy duty vinyl tile flooring, auto central door opening/closing ( All opening on same side), car position indicators, LED scrolling display, LED ceiling lights, auto voice synthesizer, overload alarming device, infrared door closing protection, door time protection, sensor based door movement, emergency alarming system, emergency light, braille push buttons, intercom, stainless steel mirror finished (lift car, lift door & hand rail), Fire rated door with 60 Mins. fire rating, Fireman's switch, Cladding at each stop(both side & top of each entrance with ply & lamination). The Elevator should be suitable for physically challenged persons.The scope of work is Supply, Erection, Testing & Commissioning of Elevator along with all related civil and electrification work. Make of the Elevator :- OTIS/MITSUBISHI/SCHINDLER/TKE (THYSENKRRUP) (Ground Floor)

1

-

1864407

... More
Constn. of 8 Nos. D type Qtrs. at Reserve Building, DCP Bhubaneswar

-

-

-

... More
CVL

-

-

-

... More
50000008 "Providing and laying reinforced cement concret of M-20 grade with 20mm and down grade black hard grinite(crusher broken) stone chips including cost of all materials, labours T&P etc. Complete but excluding the cost of reinforcement. " (Ground Floor)

139.51

-

5124.96

... More
Seventh Floor

140.45

-

5316.84

... More
Eighth Floor

25.9

-

5537.5

... More
50000010 " Providing and fixing,centering,shuttering of lintels including removal of form work at all depth and height." (Ground Floor)

102.39

-

772.6

... More
Seventh Floor

102.39

-

927.12

... More
Eighth Floor

5.05

-

1112.54

... More
50000011 "Providing and fixing,centering,shuttering of griders beams,column etc including removal of forms work at all depth and heaight. " (Ground Floor)

668.77

-

2162.13

... More
Seventh Floor

668.77

-

2594.56

... More
Eighth Floor

145.45

-

3113.48

... More
50000012 "Providing and fixing,centering,shuttering of R.C.C walls and fins etc.including removal of forms work at all depth and height. " (Ground Floor)

53.39

-

1848.41

... More
Seventh Floor

53.39

-

2218.09

... More
50000013 "Providing and fixing,centering,shuttering of R.C.C. slabs, staircase,Chajja,including removal of form work at all depth and height. " (Ground Floor)

514.02

-

1260.36

... More
Seventh Floor

514.98

-

1512.43

... More
Eighth Floor

77.71

-

1814.91

... More
50000020 "12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curring etc. All complete at all depth and height. for out side portion wall. " (Ground Floor)

1324.65

-

172.62

... More
Seventh Floor

1324.65

-

179.9

... More
Eighth Floor

420.3

-

187.55

... More
50000021 "6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smmoth including closed deep chiping and slurry treatment with necessary scaffolding,curring etc. All complete at all depth and height.for inside and out side portion. " (Ground Floor)

696.58

-

175.97

... More
Seventh Floor

703.1

-

180.51

... More
Eighth Floor

141.68

-

185.19

... More
50000022 "16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand)including necessary scaffolding curring etc. all complete at all depth and height. " (Ground Floor)

605.14

-

225.22

... More
Seventh Floor

605.14

-

231

... More
Eighth Floor

309.41

-

236.96

... More
50000023 "Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete. " (Ground Floor)

2626.37

-

74.72

... More
Seventh Floor

2632.89

-

77.95

... More
Eighth Floor

871.39

-

81.35

... More
50000034 "Supplying ,fitting and fixing of M.S. grill,M.S levoured ventiletors including cost of labour,material,transportation etc. " (Ground Floor)

2656.82

-

94.74

... More
Seventh Floor

2656.82

-

94.74

... More
Eighth Floor

1174.62

-

94.74

... More
50000039 "Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools and taxes etc. " (Ground Floor)

199.99

-

10168.05

... More
Seventh Floor

200.02

-

10199.42

... More
Eighth Floor

38.73

-

10232.36

... More
50000057 "Drip course mould plaster 1:4 (1:cement :4 sand) including necessary scaffolding curing etc complete at all depth and height as per direction of site in charge. " (Ground Floor)

285.95

-

12.37

... More
Seventh Floor

285.95

-

12.9

... More
Eighth Floor

12.15

-

13.46

... More
50000059 "Supplying,fitting & fixing of 4""dia P.V.C. rain water pipe with necessary fittings and all complete. " (Ground Floor)

24

-

130.62

... More
Seventh Floor

24

-

130.62

... More
Eighth Floor

5.4

-

130.62

... More
50000063 " One coat of priming with approved primer over new wood work. " (Ground Floor)

98.73

-

67.09

... More
Seventh Floor

98.73

-

68.82

... More
Eighth Floor

20.25

-

70.6

... More
50000071 "2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard grinite chips on new work including cost of labour,material,T&P etc all complete. " (Ground Floor)

471.82

-

586.08

... More
Eighth Floor

98.97

-

659.45

... More
50000490 "Fly Ash brick masonary in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sqcm with dimentional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc complete. In Superstructure. " (Ground Floor)

97.87

-

6480.99

... More
Seventh Floor

97.87

-

7087.63

... More
Eighth Floor

69.88

-

7785.27

... More
50000495 "Fly Ash brick masonary in cement mortar 1:4 (1 cement :4sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75 kg per sqcm with dimentional tolerance +/-8% including watering, curing and cost, coveyance, royalty of all materials and cost of labour etc complete. In Superstructure. " (Ground Floor)

32.03

-

6668.99

... More
Seventh Floor

32.03

-

7275.63

... More
Eighth Floor

3.18

-

7973.27

... More
50000884 "Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. " (Ground Floor)

98.73

-

155.67

... More
Seventh Floor

98.73

-

159.78

... More
Eighth Floor

20.25

-

164.01

... More
50000964 Fixing of Granite Flooring in floors, Treads ()(&()) Landings on 25mm thick bed of cement mortar 1:1 jointed with neat cement slury mixed with pigment to match the shades of the Granite including rubbing and polishing complete etc. (Ground Floor)

50

-

1935.41

... More
Seventh Floor

30

-

1963.44

... More
50001814 Providing & Fixing UPVC glazed sliding window with frames and shases shall be from white UPVC profile which shall have 3 hollow chambers from front to back depth of 65/118 mm. All section of frame and shases shall be reinforced with galvanized mild steel in single continious length,window shall be such that glazing or reglazing on site possible without the need to remove the outer frame from the structure of the building.The glazing must be used 5mm thick reflective glass complete in all respect as per the direction of the Engineer-In -Charge. (Ground Floor)

56.34

-

5357.14

... More
Seventh Floor

56.34

-

5357.14

... More
50004475 Providing & Fixing of ISI marked 30 mm thick Flush Door Shutters finished with 1mm thick lamination both side total thickness of 32mm flush door Shutter with 4 Nos SS butt Hinges (125x85x5.5), 2 Nos SS Tower Bolt(250x10), 1 No SS Aldrop (400 X 300), 1 No Floor type double door stopper, 2 Nos SS Handle of size 150mm, Teak wood Leaping around the edges, 1 No. Back Buffer with all materials, adhesives etc complete. (Excluding door closure, ornamental handle & Mortice Lock). As per the direction of Engineer-in-Charge. (Green /KIT /Century) [NSWI] (Ground Floor)

62.58

-

6956.95

... More
Seventh Floor

62.58

-

6956.95

... More
50004496 Providing & Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units be of approved colour using high quality pigments complete in all respect as per specification and as per the direction of Engineer-in-Charge.(Century) [NSWI] (Ground Floor)

203.8

-

1682.96

... More
Seventh Floor

203.8

-

1682.96

... More
50004506 Providing & Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250x10), 1 No SS Aldrop (400 X 300), 4 Nos. SS Butt Hinges (125x8.5x5.5), Backside Buffer with all necessary fittings Complete with approved colour as per the direction of Engineer-in-Charge. (Century) [NSWI] (Ground Floor)

12.6

-

7035.06

... More
Seventh Floor

12.6

-

7035.06

... More
50004526 Supplying, Fitting & Fixing of 10 mm thick Digital Glazed Vitrified Tile/Double charged full body vitrified tile in floor of size 600mm x 600mm of approved shade laid on 25 MM THICK cement mortar (1:1) and filling joints with epoxy grout (2mm) of approved quality including cost of all materials, labour T & P etc required for the works all complete as per direction of Engineer-in-Charge. (For new work only) (SOMANY/ KAJURIA/ NITCO / RAK/VARMORA) [NSWI] (Ground Floor)

390.64

-

1254.28

... More
Seventh Floor

390.64

-

1267.26

... More
Eighth Floor

5.65

-

1280.89

... More
50004546 Providing, Fixing & Fitting Anti-skid vitrified floor tiles of 9mm thick of size 300mm x 300mm laid over 25mm Cement mortar (1:1) laid in proper slope and filling joints with epoxy grout (2mm) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect as per the direction of the Engineer-in-charge. (SOMANY/ KAJARIA/ NITCO / RAK). [NSWI] (Ground Floor)

23.79

-

884.54

... More
Seventh Floor

23.79

-

897.52

... More
50004556 Providing, Fixing & Fitting Ceramic glazed tiles on wall of size 300mmx450mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T & P required for the work, etc. complete in all respect as directed by the Engineer-in-charge. (SOMANY/ KAJARIA/ NITCO / RAK) [NSWI] (Ground Floor)

134.58

-

990.08

... More
Seventh Floor

134.58

-

1009.61

... More
50004566 Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. (ASIAN (ULTIMA) / BURGER (Anti Dust) / and DULUX (Weather Shield).[NSWI] (Ground Floor)

732.92

-

122.03

... More
Seventh Floor

732.92

-

125.52

... More
Eighth Floor

755.39

-

129.18

... More
50004576 Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application.(ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). [NSWI] (Ground Floor)

1893.45

-

112.62

... More
Seventh Floor

1899.97

-

114.48

... More
Eighth Floor

116

-

116.4

... More
50004586 Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. [NSWI] (Ground Floor)

486.18

-

511.19

... More
Seventh Floor

374.59

-

511.19

... More
50004636 Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.(N.S.W.I) (Ground Floor)

1893.45

-

107.84

... More
Seventh Floor

1899.97

-

109.41

... More
Eighth Floor

116

-

111.03

... More
50004790 Providing and fixing Storage cabinet.(GODREJ 4 door Bookcase with Metal Top PLM Code-56101507SD00046/56/58).[NSWI] (Ground Floor)

4

-

27971

... More
Seventh Floor

4

-

27971

... More
INE

-

-

-

... More
40000946 PRecessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch /Angle holder-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

94

-

949.66

... More
40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-switch/ceiling rose-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

50

-

958.57

... More
40000952 Recessed wiring to Calling Bell Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular bell push ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-Bellpush-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

8

-

1100.41

... More
40000958 Recessed wiring to Television Point (Modular)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-switch/socket/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

16

-

1591.17

... More
40000961 Recessed wiring to Telephone Point (socket)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with socket ISI marked MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . ( Make of wire Finolex / L &T / Anchor / Havels/ V guard)(Make-switch/socket/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

8

-

927.32

... More
40000970 Recessed wiring to Ceiling Fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/ceiling rose-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

40

-

958.54

... More
40000973 Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/ceiling rose-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

24

-

958.54

... More
40000976 Recessed wiring to Security Light Point ( MODULAR)(1X36WT) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq. FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard/HPL) Make-switch/etc-Legrand /Wipro /Anchor /havells /Panasonic) (Ground Floor)

3

-

926.94

... More
40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/Socket-Legrand/ Wipro/ Anchor/ havells/ Panasonic) (Ground Floor)

97

-

526.12

... More
40000988 Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc as required as per direction of Engineer in charge . (Make of wire Finolex / L &T / Anchor / Havels/ V guard) Make-switch/Socket-Legrand/ Wipro/ Anchor/ havells/ Panasonic) (Ground Floor)

56

-

970.09

... More
40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) ( CSR SL .No- 1.8.2) (Ground Floor)

1005

-

140.02

... More
40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) ( CSR SL .No- 1.8.3) (Ground Floor)

800

-

157.2

... More
40001012 Recessed wiring to submain in 4 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / L &T / Anchor / Havels/ V guard) ( CSR SL .No- 1.8.10) (Ground Floor)

280

-

284.18

... More
40001036 Supply and laying of 35 sq.mm 3.5 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. (Sl. No -25 sl no- 5.1.2)(MAKE CABLE - FINOLEX/ HAVELLS/ POLYCAB/ KEI) (Ground Floor)

40

-

381

... More
40001129 Supplying and fixing of 6"X4" 16/18 swg metal box of following size on surface / recesss with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5) (Ground Floor)

20

-

52.66

... More
40001132 Supplying and fixing of 8"X6" 16/18 swg metal box of following size on surface / recesss with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5) (Ground Floor)

20

-

74.93

... More
40001135 Supplying and fixing of 8"X10" 16/18 swg metal box of following size on surface / recesss with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr sl.no-1.24.5) (Ground Floor)

15

-

115.98

... More
40001141 Supplying and fixing of two modular GI Box 18 swg with Modular base & cover for 2 module (Sl. No- 1301,1421) (Ground Floor)

8

-

123.81

... More
40001145 Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421) (Ground Floor)

10

-

170.63

... More
40001148 Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421) (Ground Floor)

8

-

228.7

... More
40001151 Supplying and fixing of 8 modular GI Box 18 swg with Modular base & cover for 8 module (Sl. No- 1301,1421) (Ground Floor)

20

-

270.11

... More
40001154 Supplying and fixing of 12 modular GI Box 18 swg with Modular base & cover for 12 module (Sl. No- 1301,1421) (Ground Floor)

16

-

381.76

... More
40001172 Supply of U-type fan hook (Ground Floor)

40

-

89.7

... More
40001190 Supplying and fixing of Call Bell/buzzer ISI marked suitable for DC/AC single phase 230 volts complete as required (CSR sl no-1.30) (Ground Floor)

8

-

119.63

... More
40001193 Blanking Plate (Ground Floor)

20

-

19.61

... More
40001234 supply of Stepped type modular fan regulator (Ground Floor)

40

-

249.61

... More
40001295 Supply and fixing of 4 way mcb Box ( 4+12) with 63 amp 4P Isolator/ 4P MCB & 12 nos 20 amp SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required. Make-MCB-(Legrand/L&T/ABB/SCHNIDER/ANCHOR-PANASONIC) (Ground Floor)

8

-

4269.84

... More
40001583 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS/ WIPRO/HAVELLS/PANASONIC) (Ground Floor)

94

-

120.75

... More
40001586 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections as per instruction of Electrical Engineer-in-charge (Make- CROMPTON/ PHILIPS/ WIPRO/HAVELLS/PANASONIC) (Ground Floor)

50

-

758.99

... More
40001589 Supply and fixing of 1200 mm sweep AC ceiling fan with connecting wire and all accessories including hanging and connections as per instruction of Electrical Engineer-in-charge.- [MAKE- USHA/ CROMPTON/HAVELLS/ANCHOR-PANASONIC) (Ground Floor)

40

-

1874.17

... More
40001592 Supply and fixing of 300 mm sweep square shaped louvers exhaust fan with connecting wire and all accessories including fixing and connections as per instruction of Electrical Engineer-in-charge. [MAKE- USHA/ CROMPTON/HAVELLS/ANCHOR-PANASONIC) (Ground Floor)

24

-

2024

... More
40001604 Supply & fixing of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories (Make- CROMPTON/ PHILIPS/ WIPRO/HAVELLS/PANASONIC) (Ground Floor)

3

-

3294.75

... More
40001876 Supply and fixing of 16 Amp top(for inverter installation) with all accessories and conncetion as per instruction of Electrical-Engi neer-in-Charge (Ground Floor)

16

-

80.5

... More
40001879 Recessed wiring in 1X1.5sqmm (For inverter)FR PVC insulated single core multistrand copper conducter of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick as per direction of Engineer in charge(Make of wire Finolex/L &T/Anchor/Havels/V guard) (Ground Floor)

500

-

105.87

... More
40002086 Air-Terminal Supply, Installation, Testing & Commissioning of Early Streamer Emission (ESE-30))type Lightning Air Terminal. Supporting Mast The mounting pole used to support the lightning air terminal shall be minimum length of 05 Mtr. , non corrosive and made up of medium class GI / SS pipe of 1.5″ diameter having base plate at bottom for securely fixing the mast on roof top. The mounting pole and supports shall be securely fixed with the brackets and PVC insulated metallic guy wires to withstand the maximum wind velocity of that area. Protection Radius :- 48 Mtr Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. (Ground Floor)

1

-

99250

... More
40002089 Lightning Strike Counter Supply, Installation, Testing & Commissioning of non-electronic & non-resettable (Not require any external power supply) type lightning strike counter to count the lightning stroke having display with IP-67 enclosure including all accessories and connection..(6/7 digit) Make :- ABB / STROMKING All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. Engineer-in-Charge. (Ground Floor)

1

-

27250

... More
40002095 Supply, Installation, Testing & Commissioning of maintenance free chemical earthing having enhancing chemical compound with 3 Mtr. Long copper bonded steel rod and suitable termination clamp including all accessories. Make :- ABB / STAR-X / UNIVERSAL All the work should be carried out as per the specified specifications and instruction of the Engineer-in-Charge. (Ground Floor)

6

-

16650

... More
40002720 Supply and laying of 70sqmm single core FR PVC insulated unseathed copper conductor for voltage grade 1100 volt as per IS-694 in sur face/underground as required(sl no-5.5.2)(Make-KEI/FINOLEX/HAVELLS) (Ground Floor)

100

-

1034.22

... More
40002783 SUPPLY AND FIXING OF FLOOR / WALL MOUNTED MAIN PANNEL BOARD MADE OUT OF 1.6MM C.R.C.A. SHEET DULY POWDER COATED HAVING FOLLOWING ARRANGEMENTS. [DULY WIRED WITH SOCKETING] ALL MAIN SWITCHES – (SIMENS / L&T / HPL /ABB ) ALL MCB – Legrand/L&T/ABB/SCHNIDER/ANCHOR-PANASONIC ALL CUT OUT – ANCHOR /BPC MAKE ALL WIRINGS – FINOLEX / RR/POLYCAB SIZE OF COPPER BUS BAR - AS PER RATING OF INCOMING MAIN SWITCH WITH COPPER NUT BOLT NEUTRAL LINK – AS PER MAIN SWITCH CURRENT RATING VOLTMETER & AMMETER – AE / CAPPA INDICATOR – LED SELECTOR SWITCH – SALZAR / SURDHI BUS BAR INSULATOR – RESIN CAST DRUM INSULATOR BUS BAR CHAMBER MUST BE COVERED WITH 3 MM THICK BAKELITE COVER[NATIONAL / ROYALAM]( AS PER ENCLOSED DRAWING) 1 Set : LED type R-Y-B phase indicating lamps with control fuses. LIFT PANEL BOARD 1 No 125 A, 4P onload change over switch 1 No 100 A,35 KA, TP MCCB Out Going Busbar- 4 Nos 150A, 500V Electrolytic copper strips 100 Amp 4P MCCB-2 Nos Instruments 1 No of 0-100A amperemeter with CTS with selector switch 1 No of 0-500V voltmeter with selector switch 1 Set : LED type R-Y-B phase indicating lamps with control fuses. (Ground Floor)

1

-

81538.59

... More
IPH

-

-

-

... More
10000000 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 15mm nominal outer dia pipes (Ground Floor)

67

-

171.12

... More
10000002 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 20mm nominal outer dia pipes (Ground Floor)

104

-

223.48

... More
10000004 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 25mm nominal outer dia pipes (Ground Floor)

36

-

300.63

... More
10000006 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 40mm nominal outer dia pipes (Ground Floor)

56

-

584.65

... More
10000008 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. For 50mm nominal outer dia pipes (Ground Floor)

132

-

896.78

... More
10000020 Providing and fixing on wall face unplasticised Rigid PVC soil,waste and rain water pipes conforming to IS : 13592 Type A,including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion, (i)single socket pipes. For 110mm diameter U-PVC SWR pipes. (Ground Floor)

112

-

346.68

... More
10000164 Extra over item Water Tank for hoisting Rotational moulded polyethylene cylindrical vertical water storage tanks of the following size for every additional height of 5 metres or part thereof (Hoisting Charges). (Ground Floor)

105

-

165.31

... More
10000180 Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to JAQUAR MAKE of brand code(CNS-WHT-755SS and CNS-WHT-207) including automatic flushing systern of viteros china make and seat cover fixing to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification.(Bowl for couple closet -WC with soft closing seat cover size:360x680x775,Strap-220mm,cistern with cistern fittings for 755 SS). (Ground Floor)

16

-

8092.98

... More
10000186 Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-2004 / JAQUAR MAKE with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification.(Vitreous china flat back wash basin 550x400x200 mm)(CODE CNS-WHT-801) with(CNS-WHT-301 FULL PEDESTAL) (JAQUAR MAKE). (Ground Floor)

24

-

6392.97

... More
10000194 Fixing of Screw-down TWO WAY Bib Cocks (Taps) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Head & high quality),(15mm diameter Two way short body bib cock (CODE CON-041KN). (Ground Floor)

16

-

1379.81

... More
10000198 Fixing of Screw-down SHORT BODY Bib Cocks (Taps) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Head & high quality)(15mm diameter short body bib cock(CODE CON-037KN). (Ground Floor)

24

-

843.79

... More
10000200 Fixing of Screw-down SINK Cocks (Taps) polished bright conforming to (JAQUAR MAKE) with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Head& high quality),(15mm diameter Sink Cock (CODE CON-347KN). (Ground Floor)

8

-

1915.83

... More
10000206 Fixing Chromium Plated Shower rose conforming OHS-1985 (JAQUAR MAKE)including polishing all complete as per specification.(Deluxe Head &Heavy quality). (Ground Floor)

16

-

1133.22

... More
10000208 Fixing Chromium Plated Arm of 15mm or 20mm inlet conforming to (Shower Arm Casted 190mm Long Light Body Round Shape for Wall mounted Showers with flange, SHA-477) (JAQUAR MAKE)including polishing all complete as per specification.(Deluxe Head &Heavy quality). (Ground Floor)

16

-

694.65

... More
10000210 Fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of the following nominal bore as per specification( Fixing of CP wall mixture conforming to CON-219KN) ( JAQUAR MAKE). (Ground Floor)

16

-

3719.66

... More
10000212 Fitting,Fixing of Health faucet conforming to(Hand Shower (Health faucet) ABS Body with 8mm Dia 1.2 Meter Long Flexible Tube & Wall Hook, ALD-CHR-593-N),( JAQUAR MAKE) including all complete as per specification.(Chrome Finish) (Ground Floor)

16

-

1279.4

... More
10000216 Fixing Chromium Plated soap dish Holder complete with Chromium Plated brass brackets fixed to P.V.C plugs with Chromium Plated brass screws as per specification.(JAQUAR MAKE,BRAND ACN-1131N). (Ground Floor)

24

-

928.77

... More
10000218 Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification.(600mm Long glass shelf (JAQUAR MAKE BRAND ACN-1171N), (Ground Floor)

16

-

1484.87

... More
10000222 Fixing standard sized towel rail of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.(Single towel rail 600mm long),( BRAND CODE ACN-1111NM),(Heavy quality). (Ground Floor)

16

-

1553.2

... More
10000224 Fixing standard sized towel ring of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification.(Towel Ring Round With Round Flange (BRAND CODE ACN-1121BN). (Ground Floor)

24

-

960.6

... More
10000230 Fixing standard size Chromium Plated Toilet paper holder fixed to woden plugs with Chromium Plated brass screws complete as per spec ification.(Toilet Roller Holder ACN-1151N,JAQUAR Make).with all fittings. (Ground Floor)

16

-

880.24

... More
10000292 Laying in trenches OD PVC pipes and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by non-heat application method including testing as per specification complete. 160mm dia OD P.V.C SWR double socket pipes (ISI TYPE-A),Analysis is done as per AR-2013,SLNO-2.3.2 . (Ground Floor)

40

-

668.1

... More
10000298 Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110MM DIA PLAIN BEND P.V.C SWR TYPE (Ground Floor)

4

-

166.02

... More
10000300 Providing and fixing on wall face PVC SWR moulded fittings / accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion .110mm dia bend with door P.V.C SWR TYPE (Ground Floor)

40

-

199.04

... More
10000304 Fixing 110mm size ‘P’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification.110 MM DIA P.V.C SWR P-TRAP (Ground Floor)

32

-

306.72

... More
10000308 Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification.110mm dia GULLY Trap P.V.C SWR TYPE (Ground Floor)

32

-

482.77

... More
10000334 Providing and fixing Stainless Steel kitchen sink with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.40"X20"X10" STEEL sink single bowl with drain board (PARRY WARE) as per the direction of the E.I.C . (Ground Floor)

8

-

8824.78

... More
10000338 Fixing of U.P.V.C Ball Valve of 50mm diameter conforming to the following nominal sizes with wheel as per specification complete .(S olvent Welded With Metal Ball) As per the direction of the E.I.C . (Ground Floor)

2

-

2413.32

... More
10000344 Fixing of U.P.V.C Ball Valve of 20mm diameter conforming to the following nominal sizes with wheel as per specification complete .(S olvent Welded With Metal Ball) As per the direction of the E.I.C . (Ground Floor)

32

-

404.28

... More
10000352 Fixing of C.P Screw-down Stop Cocks conforming to of the following nominal sizes as per specification complete. (Deluxe Head& high quality),15mm diameter angular stop cock ( ANALYSIS DONE AS PER AR-2013 SL NO-3.2.16 (Ground Floor)

32

-

850.57

... More
10000376 Fixing Frammed mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification.AR.-2013,SL.-NO-3.4.26. (Ground Floor)

24

-

719.21

... More
10000704 Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the E.I.C .3Layer Cylinderical Vertical water storage tanks (Details of cost for one Tank On the roof of ground floor) (Ground Floor)

12000

-

12.3

... More
10000708 Supply fitting fixing of side jally at required places where water drainage are provided as per the direction & instruction of the E.I.C . (Ground Floor)

32

-

150

... More
APPROVED MAKE / BRAND FOR CIVIL WORK

-

-

-

... More
a) CEMENT : ULTRATECH, LAFARGE, ACC ,OCL & BIRLA GOLD

-

-

-

... More
b) STEEL : SAIL , VIZAG TATA TISCON, RINL, JINDAL STEEL

-

-

-

... More
c) ALL TYPE OF FLOORING WORKS : JHONSHON & JHONSHON, KAJARIA, NITCO, ORIENT Bell, SOMANY. Cement paint & Anti fugal weather coat of ASIAN PAINT & BERGER of approved brand & quality.

-

-

-

... More
APPROVED MAKE / BRAND FOR P.H. WORK

-

-

-

... More
a) C.P.V.C , Pipes & Fittings:- According to IS:15778 (Make-Supreme,Oriplast)as per specification.

-

-

-

... More
b) Soil Water Rain Pipes(U.P.V.C Type) & fittings:- According to IS 13592/1992(Type-A) & Fittings belonging to IS 14735/1999 (Make-Supreme, Oriplast )as per specification.

-

-

-

... More
d) Ceramic Ware Items :- Wash Basins ,Standing Urinal both type (Long,Short): According to IS 2556 Part-4 2004 (Basin), IS 2556 Part-6 1996(standing urinal) (Make- W. C JAQUAR MAKE & BASIN- JAQUAR MAKE)as per specification.

-

-

-

... More
e) All Chromium Plated Brass Fittings & Fixtures :- According to IS:781-1995 (Make-Jaquar, Cohler & Rokas) as per specification.

-

-

-

... More
f) CPVC Valves as per specification.

-

-

-

... More
g) Kitchen Sink:- Stainless steel sink IS 13983 as per specification.

-

-

-

... More
h) PVC Connection Pipe:- Both end brass nuts with washers

-

-

-

... More
i) Mirror:- PVC Frame with Darwar Shape- Elegant, Charlee as per specification.

-

-

-

... More
k) U.P.V.C Pipes 4kg/sqcm (0.60mpa):- According to IS 4985/2000(Oriplast, Supreme) as per specification.

-

-

-

... More
k) CPVC supreme as per Class -1 SDR- 11 according to ASTMD-2846 as per specification.

-

-

-

... More
l) G.I. Pipe (Medium):-(TATA &ZINDAL ) IS 1239/1992 If required as per specification.

-

-

-

... More
m)10 litr capacity Low level PVC cistern :-(make -parry ware,cera) IS 7231/1994 as per specification.

-

-

-

... More
CESS

1

-

940365.24



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.