Odisha State Housing Board Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha State Housing Board - OSHB Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 Dec 2023
Closing Date5 Jan 2024
Tender Amount₹ 4,38,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3rd Floor

8.78

1563

178.08

... More
4th Floor

8.78

1641

186.98

... More
5th Floor

8.78

1723

196.33

... More
6th Floor

8.78

1809

206.14

... More
7th Floor

8.78

1900

216.45

... More
8th Floor

8.78

1995

227.27

... More
9th Floor

8.78

2095

238.64

... More
Dismantling brick or stone masonry in lime or cement mortar under 3M height including stacking the useful materials for reuse and removing the debris within 50m lead.

53.47

64960

1214.9

... More
Dismantling brick or stone masonry in lime or cement mortar above 3M. height including stacking the useful materials for reuse and removing the debris within 50M. lead. Ground Floor

11.96

15393

1287.12

... More
1st Floor

1.44

1946

1351.47

... More
2nd Floor

1.44

2043

1419.04

... More
3rd Floor

1.44

2145

1490

... More
4th Floor

1.44

2252

1564.5

... More
5th Floor

1.44

2365

1642.72

... More
6th Floor

1.44

2483

1724.86

... More
7th Floor

1.44

2607

1811.1

... More
8th Floor

1.44

2738

1901.65

... More
9th Floor

1.44

2875

1996.74

... More
Removing old lime or cement plaster from walls including racking out joint 12mm deep and removing the debris within 50 metres lead. Ground Floor

34.53

1517

43.95

... More
1st Floor

24.49

1130

46.15

... More
2nd Floor

24.49

1186

48.46

... More
3rd Floor

24.49

1246

50.88

... More
4th Floor

24.49

1308

53.43

... More
5th Floor

24.49

1373

56.1

... More
6th Floor

24.49

1442

58.9

... More
7th Floor

24.49

1514

61.85

... More
8th Floor

24.49

1590

64.94

... More
9th Floor

24.49

1669

68.19

... More
Providing & Laying cement concrete( 1:4:8) with 40mm size cbhg metal

4.32

18166

4205.3

... More
RCC M25 with bhg chips

-

-

-

... More
In roof slab

2.16

20380

9435.6

... More
RCC walls & fins Ground Floor

1.86

3395

1825.3

... More
1st Floor

1.32

2705

2049.7

... More
2nd Floor

1.32

3060

2318.4

... More
3rd Floor

1.32

3485

2640.4

... More
4th Floor

1.32

3994

3026.2

... More
5th Floor

1.32

4604

3488.4

... More
6th Floor

1.32

5335

4042.3

... More
7th Floor

1.32

6212

4706.1

... More
8th Floor

1.32

7261

5501.5

... More
9th Floor

1.32

8520

6454.8

... More
Supplying,Straightening,bending,binding & placing uncoated hysd barsreinforcement as per the direction of the EIC. Ground Floor (Consider 120kg/cum)

482.11

43520

90.27

... More
1st Floor (Consider 120kg/cum)

158.11

14313

90.53

... More
2nd Floor (Consider 120kg/cum)

158.11

14356

90.8

... More
3rd Floor (Consider 120kg/cum)

158.11

14400

91.08

... More
4th Floor (Consider 120kg/cum)

158.11

14448

91.38

... More
5th Floor (Consider 120kg/cum)

158.11

14497

91.69

... More
6th Floor (Consider 120kg/cum)

158.11

14549

92.02

... More
7th Floor (Consider 120kg/cum)

158.11

14603

92.36

... More
8th Floor (Consider 120kg/cum)

158.11

14659

92.72

... More
9th Floor (Consider 120kg/cum)

158.11

14720

93.1

... More
Brick work with Fly Ash brick with CM(1:4) in foundation & plinth Ground Floor

18.03

80469

4463.1

... More
1st Floor

1.44

6841

4750.8

... More
2nd Floor

1.44

7317

5081.6

... More
3rd Floor

1.44

7865

5462.1

... More
4th Floor

1.44

8495

5899.6

... More
5th Floor

1.44

9220

6402.8

... More
6th Floor

1.44

10053

6981.4

... More
7th Floor

1.44

11011

7646.8

... More
8th Floor

1.44

12113

8412

... More
9th Floor

1.44

13380

9292.1

... More
6mm thick Cement Plaster with CM(1:4)over RCC surface ( data for one sqmt.) Ground Floor

14.62

2387

163.3

... More
1st Floor

10.37

1764

170.2

... More
2nd Floor

10.37

1840

177.5

... More
3rd Floor

10.37

1920

185.2

... More
4th Floor

10.37

2003

193.2

... More
5th Floor

10.37

2091

201.7

... More
6th Floor

10.37

2182

210.5

... More
7th Floor

10.37

2279

219.8

... More
8th Floor

10.37

2380

229.6

... More
9th Floor

10.37

2486

239.8

... More
16mm thick Cement Plaster with CM(1:6)over brick work, ( data for one sqmt.) with integral waterproofing compound @ 200ml per one cement bag Ground Floor

173.7

30918

178

... More
1st Floor

24.49

4530

185

... More
2nd Floor

24.49

4702

192

... More
3rd Floor

24.49

4898

200

... More
4th Floor

24.49

5093

208

... More
5th Floor

24.49

5289

216

... More
6th Floor

24.49

5510

225

... More
7th Floor

24.49

5755

235

... More
8th Floor

24.49

6000

245

... More
9th Floor

24.49

6244

255

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.

-

-

-

... More
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer Ground Floor

2.48

211

85.25

... More
1st Floor

1.76

152

86.56

... More
2nd Floor

1.76

154

87.95

... More
3rd Floor

1.76

157

89.4

... More
4th Floor

1.76

160

90.92

... More
5th Floor

1.76

162

92.52

... More
6th Floor

1.76

165

94.2

... More
7th Floor

1.76

168

95.97

... More
8th Floor

1.76

172

97.82

... More
9th Floor

1.76

175

99.77

... More
Making plinth protection 75mm thick of cement concrete 1:3:6 (1 cement : 3 Mortar Sand : 6 cbhg metal aggregate 20 mm nominal size over 75mm thick bed of dry brick khoa 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

47.8

28190

589.75

... More
PCC (50 mm)(1:2:4) for plinth protection

2.39

14103

5901.1

... More
Providing and laying weather and Ultravoilet Resistant, Water Repellent, Dust, Dirt and Stain Resistant, Fungus and Algae Resistant natural none pigmented crushed granite Chips (100% natural crushed Granite chips/powder) of approved make with final coat of texture with stone chips (attainable thickness: 0.70 to 0.90mm to offer grooved finish) applied with Spray over a coat of texture without chips (attainable thickness: 0.50 to 0.70mm to offer smooth surface as base coat) over a repair check with exterior grade cement mixed with acrylic primer over a coat of acrylic primer mixed with wall sealer in the ratio of 1:1 complete as approved by Engineer-in-charge. Finally one coat of water base acrylic protection coat applied with roller and brush to make surface streak resistance

6614.22

7337154

1109.3

... More
INTERIOR RENOVATION GROUND FLOOR Dismantling and removing R.C.C. chajja, shelves, fins and parapet including stacking the useful materials for reuse and removing the debris within 50m lead in Ground Floor

2

307

153.83

... More
Dismantling brick or stone masonry in lime or cement mortar under 3M height including stacking the useful materials for reuse and removing the debris within 50m lead.

2.79

3389

1214.9

... More
Dismantling brick or stone masonry in lime or cement mortar above 3M. height including stacking the useful materials for reuse and removing the debris within 50M. Lead in Ground Floor

22.29

28689

1287.12

... More
Removing old lime or cement plaster from walls including racking out joint 12mm deep and removing the debris within 50 metres lead in Ground Floor

79.94

3513

43.95

... More
Dismantling and removing doors and windows and ventilators including removals of frames, hinges, fastening and stacking the same for reuse and removing the debris within 50 metres lead in Ground Floor

11.39

3954

347.2

... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-incharge in Ground Floor

34.7

733

21.15

... More
Providing & Laying Cement concrete( 1:2:4) with 12mm size cbhg chips(Per cum) in Ground Floor

3.47

20476

5901.1

... More
RCC M25 with bhg chips In roof slab in Ground Floor

0.23

2533

11014

... More
Supplying,Straightening,bending,binding& placing uncoated hysd barsreinforcement as per the direction of the EIC in Ground Floor (Consider 120kg/cum)

27.9

2518

90.27

... More
Brick work with Fly Ash brick with CM(1:4) in foundation & plinth in Ground Floor

19.03

84932

4463.1

... More
12mm thick Cement Plaster with CM(1:6)over brick work, ( data for one sqmt.) with integral waterproofing compound @ 200ml per one cement bag in Ground Floor

319.89

55980

175

... More
Stone cladding work (machine cut edges) for vertical surfaces as per drawing, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins)with Dholpur stone Tiles in Ground Floor

20.15

30249

1501.22

... More
Fixing tiles in floors,treads of steps on 20 mm thiick bed of cement mortar (1:4) including cost of tiles with VITRIFED tile flooring in Ground Floor

52.05

47183

906.5

... More
25mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with Seasoned teak wood planks for shutter in Ground Floor

44.49

138131

3104.78

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry in 1st Floor

34.7

7433

214.23

... More
Finishing wall with Acrylic emulsion paint over a coat of priming and putty finish in Ground Floor

810.71

204298

252

... More
Finishing Walls with Textured Paint of Approved shade 1. On New (2 coats) @ 3.28 liters/10sqm over a coat of Wall cement Primer @ 2.20 liters/10 sqm in Ground Floor

175.66

36224

206.22

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer in Ground Floor

6

511

85.25

... More
Granite Counter For granite slab in kitchen platform in Ground Floor

4.3

9481

2205.1

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete in Ground Floor

7

2214

316.33

... More
Mirror polishing on marble work/Granite work/stone work/Terrazo Work where ever required to give high gloss finish complete in Ground Floor

343.17

68304

199.04

... More
Dressed seasoned sal wood work framed & fixed(wrought & put up)in trusses, frames of doors & windows etc. In Ground Floor

0.1

5118

51188.9

... More
Providing 35 mm Shutter made up of sal wood frame and Block board ,6 mm ply with both side lamination in Ground Floor

9.14

47645

5212.9

... More
Supplying,fitting,fixing aluminium powder coated door made up of OEL section of 9202 as vertical member,9201 as top member and 9200 as bottom member and 8 mm toughened glass in full door fixed on door frames by means of tappered clips No 4660 and the frame to be completed by means of joining angle no 1855 including all cost of labour,T&P, hire cahrges of drilling machines,labour charges etc complete.

12.72

105672

8307.6

... More
Providing and fixing 8mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) in Ground Floor

23.1

92389

3999.54

... More
Supplying,fitting,fixing ,partition walling OEL aluminum anodised/Powder Coated section No 9210 & 9207 as as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as tappered clip for fixing up 10mm [5+5] toughned sandwitch glass along with fabric and jointing angle No 1855 etc.

4.64

41735

8994.67

... More
Supplying,fitting,fixing aluminium door made up of OEL section of 9202 as vertical member,9201 as top member and 9200 as bottom member and 8 mm plain glass in full door fixed on door frames by means of tappered clips No 4660 and the frame to be completed by means of joining angle no 1855 including all cost of labour,T&P, hire cahrges of drilling machines,labour charges etc complete.

2.04

15502

7599.04

... More
Supplying,fitting,fixing ,partition walling OEL aluminum anodised section No 9210 & 9207 as as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as tappered clip for fixing up 10mm (5mm + 5mm) fixed sandwitched glass along with banana paper and jointing angle No 1855 etc.

10.71

101970

9521.03

... More
Supplying,fitting,fixing ,partition walling OEL aluminum anodised section No 9210 & 9207 as as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as tappered clip for fixing up 10mm (5mm + 5mm) fixed sandwitched glass along with banana paper and jointing angle No 1855 etc in Ground Floor

11.4

17909

1571.05

... More
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately) in Ground Floor

6.3

48320

7669.91

... More
Providing and fixing non load bearing fixed frame for fire resistant glazed partition for 120 minutes fire rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density minimum 96kg/ cum. and finished with a approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016 and directions of Engineer - in- Charge in Ground Floor

25

38812

1552.49

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm in Ground Floor

0.68

24057

35379

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete in Ground Floor

4

25476

6369.11

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete in Ground Floor

4

2871

717.89

... More
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.

-

-

-

... More
The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)

7.66

13770

1797.65

... More
Supplying, fitting, fixing vitrified tiles in flooring of size 600mm x600mm of approved make of premium grade with application of polymermodified cement based water resistant adhesive and filling the joints with epoxy grouts etc for 1 sqmt in Ground Floor

34.7

34117

983.2

... More
Fixing vitrified tiles in dados,risers of steps on12 mm thick bed of cement mortar (1:3) including cost of tile in Ground Floor

103.26

104891

1015.8

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :

-

-

-

... More
12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks)

10

12864

1286.45

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.

-

-

-

... More
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

10

17462

1746.25

... More
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.

7.66

2354

307.35

... More
Providing and fixing looking mirror of superior glass (of approved quality) and of required shape and size of approved make and shade with 16 mm thick BWR Block board backing : a) Square Shape of 600 x 600 mm in Ground Floor

6

13377

2229.66

... More
Providing and fixing 18 mm thick, 150 mm wide pelmet of pre laminated particle board(standard,ISI), , including top cover of 6 mm BWR ply wood, including fixing with all necessary screws and hardwares etc. all complete as directed by Engineer-in-charge. (Wooden Pelmets) in Ground Floor

19.2

5707

297.25

... More
CUBICALS Providing and Fixing Cubicals for washroom with the following mentioned specifications: Thickness of Compact Laminate : 12mm Color of HPL Boards: Single Standard Compact Color Special Remarks For Customizaon :. Size of Cubicle : As per Drawing (W) X (D) X 2003mm (H) Door Size : 1750mm (H) x 600mm (W) Divider Size : 1775mm (H) Overall Height Of Cubicle : 2003mm (Including boom Gap of 150mm) Accessories: Standard - a) Aluminum "U" Channel b) Aluminum "F" Channel (Only Corner Unit) c) Aluminum Door Stopper Channel d) Aluminum Top Rail e) SS Coat Hook f) SS Privacy Thumb turn c/w Occupancy Indicator g) SS Door Knob h) SS Spring Loaded Bu Hinges with Cover i) SS Adjustable Foot 316 Grade j) Rubber Door Stopper Lining k) S.S.Screws 304 G & P.V.C Wall Plugs SPECIAL NOTE - Warpage Criteria is 3.0 mm/1000mm for MRS panels as per EN standard- 438.

4

119702

29925.58

... More
PIN BOARDS Supply and fixing pin boards of size 1200MM(L) x 450MM(H) made of 25 x 3mm Teakwood lipping work all round and fitted with a pin – up board made of soft board with 6mm BWR Ply backing and wrapped with approved colour and finish of fabric (handloom fabric like Kotpad cotton or Bomkai cotton etc) complete with all accessories to be fixed on workstations. The TW lipping finished to desired wood effect by melamine polish after necessary surface preparation   in Ground Floor

12

18975

1581.31

... More
ROMAN BLINDS Providing and fixing manually operated roman blind MAC, Vista or equivalent having chain mechanism in desired design and shade complete in all respect, with fabric in approved colour and finish (handloom fabric like Kotpad cotton or Bomkai cotton etc , minimum fabric thickness 0.6-0.7 mm, fire resistance NFPA 701:2000 5 grade colour fastness to light) in Ground Floor Makes - MAC, Vista, Deco, Magnum

29.01

40579

1398.82

... More
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.

27.63

136840

4952.6

... More
Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.

3.66

31722

8667.38

... More
FURNITURE TABLES 16 Seater Conference Table of size 5400 x 1200mm - Chairman's Table Providing and fixing 5400mm X 1200mm wide Conference table fabricated out of three pieces of 15 mm thick White Makrana marble of approved shade with inlay work on table as per drawings including bevelled edge and double stone facia fixed over 19mm thk. BWR Ply both 150mm a part, fixed with powder coated MS studs as per architectural drawing fixed with powder coated MS Pipe Section as per drawings & with powder coated MS Brackets of required size with column & boxing complete as per drawings including cable management system and pop up boxes complete to the satisfaction of Architect.

1

67000

67000

... More
Reception table of size 2100 x 600mm made of commercial ply board finished with veneer of architects choice and natural polish. Foot rest to be given in the table, as per design. top to be rested on sides of the table made with commercial plyboard finished with veneer on the outside. No Modesty board, but front to be covered using teak sleepers size 4” x 1.5” stacked one over the other and fixed to each other to a height of 40 inches. As per design and finished with natural polish.

1

60000

60000

... More
Chairman room table of size 2100 x 750mm made using 19mm thick commercial plyboard finished with 3mm thick veneer as selected by architect. The outer edge (outer, shorter, one side only) of the table to be decorated with local metal artwork made of premium MS as per design . The Frame + legs of the table to be made of cp teak finished size 1.5” x 2” including the angled footrest. with provision for cable management. The table to be finished with natural look melamine polish.

1

55000

55000

... More
Modular Furniture Tables + equiptment Providing of modular office Workstations of size 1200 x 600mm x 740mm(h) made of 25mm thick prelam particle board with MS powder coated frame complete with accesorries All exposed edges to be finshed with 2mm thk PVC edge banding. (basic rate - 30,222Rs) Make - Godrej, Wipro, Featherlite

18

700792

38932.92

... More
Extra for Godrej Keyboard tray 480 x 280 x 40mm (basic rate - 1,155Rs) Make - Godrej, Wipro, Featherlite

18

38911

2161.76

... More
Extra for under desk storage Pedestal 646 x 390 x 440mm with castor wheels ( basic rate - 5,562 Rs) Make - Godrej, Wipro, Featherlite

18

187464

10414.68

... More
Providing and fixing of 1800mm(L) x 750mm(W) x 740mm(H) main table made of 3/4" thk plyboard top with rounded corners and 1500mm(L) x 600mm(W) x 740mm(H) return table of 18mm thk plyboard with under-table partitions of 1/2" thk plyboard vertical and horizontal partitions with shutters made of 1/2" thk plyboard as per design and details. All plyboards with 3mm thk veneer in approved shade and finish (same as existing, basic rate - 30,222Rs) Make - Godrej, Wipro, Featherlite

1

50996

50996.06

... More
Centre table – 750mm diameter, Wood : Solid Sheesham Wood. Legs made of Rust-proof premium metal. (Basic Rate 11,999 Rs) SARAF Furniture MG road or equivalent

2

34068

17034.48

... More
Side table – 460mm diameter, Wood : Solid Sheesham Wood. Legs made of Rust-proof premium metal. (Basic Rate 5,499 Rs) SARAF Furniture MG road or equivalent

5

73915

14783.04

... More
Chairman Cabin Center table - 600mm x 1200mm, Solid Sheesham Wood. Legs made of Rust-proof premium metal. (basic rate of table - 10,999 Rs) SARAF Furniture MG road or equivalent

1

17034

17034.48

... More
Meeting Room table - 6 seater Providing and fixing of 1800mm(L) x 900mm(W) table made of 1" thk prelaminated particule board fixed over MS frame of 2"x2"cross section powder coated in approved shade and MS posts of 2"x2" cross section powder coated in approved shade as per design and details with provision for in-furniture electrical wiring within pop up boxes (Base rate = 41,559) Make - Godrej, Wipro, Featherlite

-

-

-

... More
Meeting Room table 4 Providing and fixing of 1400mm(L) x 900mm(W) table made of 1" thk prelaminated particule board fixed over MS frame of 2"x2"cross section powder coated in approved shade and MS posts of 2"x2" cross section powder coated in approved shade as per design and details with provision for in-furniture electrical wiring within pop up boxes (Base rate = 30,999) Make - Godrej, Wipro, Featherlite

-

-

-

... More
Modular Furniture: Chairs Supplying and placing Godrej Thrive high chair with headrest (basic rate - 14,670) for workstation employees. Make - Godrej,Wipro,Featherlite

28

535578

19127.8

... More
Supplying and placing Godrej Ace high chair with headrest and coat hanger (basic rate - 14,670Rs) – For chairman and executive officers Make - Godrej,Wipro,Featherlite

2

47912

23956.36

... More
Supplying and placing Godrej Ace high chair with headrest or equivalent and coat hanger (basic rate - 14,670Rs) – For boardroom and chairman conference room Make - Godrej,Wipro,Featherlite

28

670778

23956.36

... More
Supplying and placing of Fixed Leatherite chair ( basic rate - 9,599Rs ) – for executive visitor Make - Godrej,Wipro,Featherlite

2

25195

12597.68

... More
Supplying and placing of Common chairs – circular fixed chair foam cushioned and uphoslteredwith leatherette seat (Fabric base rate 450Rs/metre) and teak wood frame as per design finished with natural melamine finish as per the satisfaction of the architect/client (base rate 7500Rs) Make - Godrej,Wipro,Featherlite

15

88836

5922.42

... More
Supplying and placing of Modular Waiting Matrix chair of dimensions 114.5 x 78.5 x 63.8 (set of 4 seats)with anthracite coated Mild Steel Frame with cushioned and upholstered seats in leatherite fabric (basic rate fabric = 450rs/mtr) in approved color and finish as per architect basic rate of chair assembly 14,999 Rs. Make - Godrej, Wipro or equivalent

5

138408

27681.62

... More
Modular Furniture:SOFAS Sofa - 3 seater Supplying and making of 2120mm(L) x 820mm(W) x 400mm(H)seat and 650mm(H)seat backrest double seater cushioned sofa, polyurethene filled softie filler and 25 density upholstered foam seat over a wooden structure of specified make with the approval of the client or architect. 4" high legs of the sofa to be made of teak wood finished with natural melamine finish. (Base rate 55,999Rs.) Make Godrej, Wipro, Featherlite

1

47415

47415.94

... More
Sofa - 2 seater Supplying and placing of 1530mm(L) x 820mm(W) x 650mm(H) double seater cushioned sofa, polyurethene filled softie filler and 25 density upholstered foam seat over a wooden structure of specified make with the approval of the client or architect. 4" high legs of the sofa to be made of teak wood finished with natural melamine finish. (Base rate 31,999Rs.) Make Godrej, Wipro, Featherlite

4

154938

38734.68

... More
Modular Furniture:STORAGES Cost of the storage units to be inclusive of brushed steel finish handles , SS hinges, tower bolts, Shutter magnets (Medium), locks, tower bolts, magnetic ball catch, hinge etc and all necessary hardware of approved make all complete as per drawing and detail and as per the instructions of the architect. The storages to have a support member of SS brushed steel section as per detail/design/design as provided by the Architect.All storage units to have shutters fabricated out of 18mm MDF/ 19mm Commercial Board. All exposed edges to be finshed with 2mm thk PVC edge banding. Double shutters to have 3" SS stoppers on top and bottom of one shutter (inside) and a lock on the other side other than the necessary hardware's. The shelves ( nos. as per architects drawings) to be of 19mm thk block board finished on both sides with 0.8 mm liner laminate. All exposed edges to be finshed with beading, finished with melamine polish. All shelves to be kept radjustable, using S.S 20mm bats as supports.All laminate fixing to ensure absence of 'bubbles/etc', indicating improper finishing techniques applied; all such instances, if and as/when observed, shall need to be rectified by the appropriate contractor(s), at their sole risk and responsibility.

-

-

-

... More
All Storages/Counters to be factory finished as per actual dimensions as on site, and fixed on site as per Architects details/Drawings.Cost to include 150mm vertical Splash back in laminate as per detail drawings. Elevation area/face area will be considered for measurement Low height storage with top Size: depth of 350mm to 450mm Providing and fixing low height storage of size not more than 800m high X 350-450mm deep , fabricated out of 19mm block board with 0.8 mm liner laminate on the inside. Shelves also to be lined with 0.8mm laminate from inside. All exposed edges to be finshed with 2mm thk PVC edge banding. Wherever there is solid wall surface, BWP board to be used instead of block board backing Basic Rate of Laminate: Merino Arctic White plain/EQV as selected, matching PVC edge binding from REHAU/Eqv With Visible face including top and shutters finished in 3mm thick Veneer (natural Polish paid for separately) With Visible face including top and shutters finished in 1mm thick laminate With Visible face including top and shutters finished in MDF/commercial board (finishing with duco paint paid for separately)

2

42067

21033.5

... More
Full height storage Size: 450 – 700 mm deep x 2100 mm high Providing and fixing full height storage of size not more than 2100mm high X 450-700mm deep , fabricated out of 19mm block board with 0.8 mm liner laminate on the inside. Shelves also to be lined with 0.8mm laminate from inside. All exposed edges to be finshed with 2mm thk PVC edge banding. Wherever there is solid wall surface, BWP board to be used instead of block board backing Laminate: Merino Arctic White plain/EQV, matching PVC edge binding from REHAU/Eqv With Visible face and shutters finished in 3mm thick Veneer (natural Polish paid for separately)

20

290000

14500

... More
DRY PANTRY Size: 700 mm deep x 900 mm high Providing and fixing under counter storage of size not more than 900mm high X 700mm deep , fabricated out of 19mm BWP board with 0.8 mm liner laminate on the inside. Shelves also to be lined with 0.8mm laminate from inside. All exposed edges to be finshed with 2mm thk PVC edge banding. Wherever there is solid wall surface, BWP board to be used instead of block board backing Laminate: Merino Arctic White plain/EQV, matching PVC edge binding from REHAU/Eqv With Visible face and shutters finished in 1mm thick laminate Extra for fixing 18mm thk granite top with bevelled edges including adhesive

1

13487

13487.4

... More
PLANTERS Providing FRP Planters of premium quality of following sizes and designs: Rectangular Shape Size : 36’’x12’’x12’’ LWH

6

10200

1700

... More
Apple Shape Size : 18’’ height

6

6000

1000

... More
Apple Shape Size : 24’’ Heght

6

7800

1300

... More
Deluxe Cylindrical Shape Size : TOP DIA 12’’ AND 24’’ HEIGHT

6

10200

1700

... More
Diamond Shape Size : 12’’X12’’x14’’ LWH

6

3300

550

... More
Diamond Shape Size : 12’’x12’’x22’’ LWH

6

7500

1250

... More
Providing decorative teak wood moulding on walls of size 75mm x 25mm polished with french spirit polish with all the necessary hardware as per the architectural drawings.

71.35

6199

86.89

... More
Providing 35 mm Shutter made up of sal wood frame and Block board ,6 mm ply with both side lamination. (ground Floor)

9.13

47593

5212.9

... More
Electrical Ground Floor LIGHT AND SOCKET OUTLET POINT WIRING The rates for point wiring for all the items shall include the following : The Point Wiring shall include the wiring of light / outlets of any length from the distribution board Via Switch to the to first point (Primary Point) All the switch boxes, outlet and junction boxes shall be covered with White Polycarbonate modular cover plate. Painting of junction boxes . Embedding conduits and allied fittings in walls/floors/slabs etc. during construction and/or in chases including cutting chases and making good as necessary in the case of concealed conduit work. All accessories necessary to complete the wiring as specified. Internal wiring between accessories. Wherever flexible conduit are required GI flexible conduit of suitable size shall be used with checknut.

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (ADMIN BLOCK/STORES/PANEL ROOMS/LOBBY/ENTRANCES ETC.

-

-

-

... More
Group A

40

37886

947.16

... More
Group B

6

6646

1107.77

... More
Group C

6

7818

1303.15

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

4

5580

1395.14

... More
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(For 16 A power socket)

375

106413

283.77

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. (For office area and workstation and partition 6A switch socket RAW power point (Maximum 4 points per circuit) + office area + meeting cabins circuit wiring for light switch board point)

500

93105

186.21

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (For workstation switch socket (Maximum 2 UPS sets per circuit)

250

56715

226.86

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

25

2969

118.76

... More
TV antenna socket outlet

3

356

118.76

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

20

6471

323.59

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

3

93

31.07

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)

28

5852

209.03

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

55

20526

373.21

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

25

11949

477.98

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

915

43435

47.47

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group A

40

18777

469.44

... More
Group B

5

2850

570.05

... More
Group C

5

3356

671.35

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For Workstation)

25

14131

565.24

... More
Supplying and drawing following pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed steel / PVC conduit as required.

-

-

-

... More
2 pair

750

31980

42.64

... More
4 pair

200

9604

48.02

... More
Supplying and fixing of following sizes of STEEL conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath

105

4585

43.67

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm (For Data, CCTV, Telephone)

100

10624

106.24

... More
25mm (For Data, CCTV, Telephone)

400

44560

111.4

... More
32mm (For Data, CCTV, Telephone)

100

11895

118.95

... More
Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. 75 mm x 75 mm x 60 mm deep (For Data, CCTV, Telephone)

30

3839

127.98

... More
Supplying and fixing of 3 pin, 5 amp ceiling rose ISI marked on the existing junction box / wooden block including connection etc. as required.

10

448

44.89

... More
Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required.

3

187

62.56

... More
Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.

1

125

125.02

... More
Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor including providing and fixing phenolic laminated sheet steet cover on the fan box etc as required.etc. as required.

20

3307

165.37

... More
Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.

5

1127

225.55

... More
Supplying of fresh air cum exhaust fan of heavy duty 250 V AC 50 Hz 450 mm 1400 RPM rust proof body and blades wire mesh duly erected in approved manner and marking serial number and date of erection and complete with louvers and frame Make:- Crompton, Havells, Usha

5

26392

5278.5

... More
Supply Installation, Testing and commisioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, including connection, earthing, dash fastner (hanging arrangements) etc. complete as per engineer incharge Make:- Crompton, Havells, Usha

20

42228

2111.4

... More
LIGHTING FIXTURE AND CEILING FANS / EXHAUST FANS

-

-

-

... More
Supplying Installation, Testing and commisioning of Linear Suspended light 1000/1200 mm x 50 MM W 24-30 W / Mtr powder coated in colour of architects choice with End Caps Light should be customized for interconnectivity to achieve seemless light using UV resitant Polycarbonate diffuser. LED printed circuit board should be mounted on top of housing. System efficiancy 110 lumens / watt. LED's should be certified safe through Photobiological report for Blue Effect. Silicon encapsulated high efficient LED Driver to reduce impact of temp, voltage and current rise. Driver Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85. CCT should be 4000 Kelvin. The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Suspension wire length should be as per site conditions also attached with data to be Submitted with the Compliance Submission: i) Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. Data to be Submitted with the Final Submission: i) Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. ii) Mounting instruction sheets. iii) Make of LEDs/lamps, luminaire and electronic driver used Make:- (REIZ cat. No. Suspension Rapier Mini), Phillips, K-Lite

42

163500

3892.88

... More
Supplying Installation, Testing and commisioning of 12 W LED Surface mounted (on True Ceiling) Cylindrical or Square light dimensions 140 X 65 mm with extruded aluminium body, with polyster powder coated with high U.V. and corrossion resistance , heat sink , integrated HF electronic driver System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. ( TOILETS / STORES / STAIRCASE LANDINGS Make:- (REIZ cat. No. Kan Mini), Phillips, K-Lite

20

24071

1203.55

... More
Supplying Installation, Testing and commisioning of 18 W LED Surface mounted (on True Ceiling) Cylindrical or Square light dimensions 225 X 60 mm with extruded aluminium body, with polyster powder coated with high U.V. and corrossion resistance , heat sink , integrated HF electronic driver System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 75. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. (Passage, stores, conference room etc) Make:- (REIZ cat. No. Kan Mini), Phillips, K-Lite Make:- (REIZ cat. No. Glow Mini), Phillips, K-Lite

40

69466

1736.67

... More
Supplying Installation, Testing and commisioning of Dome Suspended light dia 400 mm 18-20 W powder coated in colour of architects choice with light using UV resitant Polycarbonate diffuser. LED printed circuit board should be mounted on top of housing. System efficiancy 110 lumens / watt. LED's should be certified safe through Photobiological report for Blue Effect. Silicon encapsulated high efficient LED Driver to reduce impact of temp, voltage and current rise. Driver Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 90. surge protection 3kv, CCT should be 4000 Kelvin. The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Suspension wire length should be as per site conditions also attached with data to be Submitted with the Compliance Submission: i) Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. Data to be Submitted with the Final Submission: i) Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. ii) Mounting instruction sheets. iii) Make of LEDs/lamps, luminaire and electronic driver used (RECEPTION + Breakout area) Make:- (REIZ cat. No. Suspension Umbrella 400), Phillips, K-Lite

10

64992

6499.29

... More
Supplying Installation, Testing and commisioning of 10W LED type decorative Mirror Light with polycarbonate body , heat sink , integrated HF electronic driver, System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 80. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Make:- (REIZ cat. No. I LITE), Phillips, K-Lite

6

6297

1049.53

... More
Supplying Installation, Testing and commisioning of 10W LED type Bulkhead Light with opal polycarbonate body , heat sink , integrated HF electronic driver, System efficiancy 110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85 CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Make:- REIZ, Phillips, K-Lite

2

2146

1073.23

... More
RACEWAYS Supply and fixing of following sizes of MS Cable Raceway, 14 gauge, with all accessories as required including Bends / T Joints Clamped to fCeiling / Shafts ined with connectors, suspended from the ceiling with Suitable C Channel, G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
200mm x 40mm (3 mm thick cover)

20

16389

819.48

... More
100mm x 40mm (2 mm thick cover)

70

38290

547

... More
Junction box 450mm x 50mm (3 mm thick cover)

4

9689

2422.42

... More
Junction box 250mm x 50mm (3 mm thick cover)

25

38347

1533.88

... More
SITC of Rj 45 Connector Pack Of 100 Operating Temperature: -40°C To 80°C

1

7874

7874.97

... More
Supplying and fixing following modular Dual Faceplate with accessories .

25

10676

427.06

... More
Supplying and fixing following modular RJ 45 I/O for Data with accessories on the existing face plate including connections etc as per specification.

25

6550

262.03

... More
Supplying and fixing following modular RJ 11 I/O for voice with accessories on the existing face plate including connections etc as per specification.

25

6550

262.03

... More
SITC of Ceiling Mount 802.11AX 3000 Dual band 2x2MU-MIMO Ceiling AP with Cloud Controller License 1 Year Included. WiFi 6, Warranty-5 Years, New sealed pack replacement to be provided under warranty, no repair / refurbish, product will be accepted.

3

42540

14180.25

... More
IP DOME 2MP full real time recording 1/3" CMOS Sensor, Max resolution : 1920 x 1080, True day night function, 0.03 lux color mode and  0.02 tux B/W mode at 30 IRE  Upto 30m IR distance, 3D DNR, DWDR, Support triple streams, Onvif Profile, POE S/G compliant

7

23215

3316.56

... More
IP BULLTER 2MP full real time recording 1/3" CMOS Sensor, Max resolution : 1920 x 1080, True day night function, 0.03 lux color mode and  0.02 tux B/W mode at 30 IRE  Upto 30m IR distance, 3D DNR, DWDR, Support triple streams, Onvif Profile, POE S/G compliant, IP 66

2

6988

3494.27

... More
PAVA SYSTEM Supplying, installation, testing & commissioning of 1.5/3/6Wmetal box ceiling/wall speakers complete as required.

20

33941

1697.06

... More
Supply, installation, testing & commissioinign of 6W Volume controller, 3/4 wire, ABS Material, with 24V Override Function

1

2244

2244.38

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm

250

19350

77.4

... More
Electrical Seventh Floor LIGHT AND SOCKET OUTLET POINT WIRING mnv The rates for point wiring for all the items shall include the following : The Point Wiring shall include the wiring of light / outlets of any length from the distribution board Via Switch to the to first point (Primary Point) All the switch boxes, outlet and junction boxes shall be covered with White Polycarbonate modular cover plate. Painting of junction boxes . Embedding conduits and allied fittings in walls/floors/slabs etc. during construction and/or in chases including cutting chases and making good as necessary in the case of concealed conduit work. All accessories necessary to complete the wiring as specified. Internal wiring between accessories. Wherever flexible conduit are required GI flexible conduit of suitable size shall be used with checknut.

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (ADMIN BLOCK/STORES/PANEL ROOMS/LOBBY/ENTRANCES ETC.

-

-

-

... More
Group A

52

49252

947.16

... More
Group B

8

8862

1107.77

... More
Group C

8

10425

1303.15

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

8

11161

1395.14

... More
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(For 16 A power socket)

380

107832

283.77

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. (For office area and workstation and partition 6A switch socket RAW power point (Maximum 4 points per circuit) + office area + meeting cabins circuit wiring for light switch board point)

650

121036

186.21

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (For workstation switch socket (Maximum 2 UPS sets per circuit)

370

83938

226.86

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

36

4275

118.76

... More
TV antenna socket outlet

3

356

118.76

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

19

6148

323.59

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

3

93

31.07

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)

36

7525

209.03

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

62

23139

373.21

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

20

9559

477.98

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

1015

48182

47.47

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group A

45

21124

469.44

... More
Group B

5

2850

570.05

... More
Group C

5

3356

671.35

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For Workstation)

38

21479

565.24

... More
Supplying and drawing following pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed steel / PVC conduit as required.

-

-

-

... More
2 pair

800

34112

42.64

... More
4 pair

100

4802

48.02

... More
Supplying and fixing of following sizes of STEEL conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath

105

4585

43.67

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm (For Data, CCTV, Telephone)

150

15936

106.24

... More
25mm (For Data, CCTV, Telephone)

450

50130

111.4

... More
32mm (For Data, CCTV, Telephone)

100

11895

118.95

... More
Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. 75 mm x 75 mm x 60 mm deep (For Data, CCTV, Telephone)

38

4863

127.98

... More
Supplying and fixing of 3 pin, 5 amp ceiling rose ISI marked on the existing junction box / wooden block including connection etc. as required.

8

359

44.89

... More
Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required.

3

187

62.56

... More
Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.

1

125

125.02

... More
Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor including providing and fixing phenolic laminated sheet steet cover on the fan box etc as required.etc. as required.

22

3638

165.37

... More
Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.

6

1353

225.55

... More
Supplying of fresh air cum exhaust fan of heavy duty 250 V AC 50 Hz 450 mm 1400 RPM rust proof body and blades wire mesh duly erected in approved manner and marking serial number and date of erection and complete with louvers and frame Make:- Crompton, Havells, Usha

6

31671

5278.5

... More
Supply Installation, Testing and commisioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, including connection, earthing, dash fastner (hanging arrangements) etc. complete as per engineer incharge Make:- Crompton, Havells, Usha

22

46450

2111.4

... More
LIGHTING FIXTURE AND CEILING FANS / EXHAUST FANS

-

-

-

... More
Supplying Installation, Testing and commisioning of Linear Suspended light 1000/1200 mm x 50 MM W 24-30 W / Mtr powder coated in colour of architects choice with End Caps Light should be customized for interconnectivity to achieve seemless light using UV resitant Polycarbonate diffuser. LED printed circuit board should be mounted on top of housing. System efficiancy 110 lumens / watt. LED's should be certified safe through Photobiological report for Blue Effect. Silicon encapsulated high efficient LED Driver to reduce impact of temp, voltage and current rise. Driver Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85. CCT should be 4000 Kelvin. The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Suspension wire length should be as per site conditions also attached with data to be Submitted with the Compliance Submission: i) Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. Data to be Submitted with the Final Submission: i) Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. ii) Mounting instruction sheets. iii) Make of LEDs/lamps, luminaire and electronic driver used Make:- (REIZ cat. No. Suspension Rapier Mini), Phillips, K-Lite

64

249144

3892.88

... More
Supplying Installation, Testing and commisioning of 12 W LED Surface mounted (on True Ceiling) Cylindrical or Square light dimensions 140 X 65 mm with extruded aluminium body, with polyster powder coated with high U.V. and corrossion resistance , heat sink , integrated HF electronic driver System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. ( TOILETS / STORES / STAIRCASE LANDINGS Make:- (REIZ cat. No. Kan Mini), Phillips, K-Lite

20

24071

1203.55

... More
Supplying Installation, Testing and commisioning of 18 W LED Surface mounted (on True Ceiling) Cylindrical or Square light dimensions 225 X 60 mm with extruded aluminium body, with polyster powder coated with high U.V. and corrossion resistance , heat sink , integrated HF electronic driver System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 75. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. (Passage, stores, conference room etc) Make:- (REIZ cat. No. Kan Mini), Phillips, K-Lite Make:- (REIZ cat. No. Glow Mini), Phillips, K-Lite

28

48626

1736.67

... More
Supplying Installation, Testing and commisioning of Dome Suspended light dia 400 mm 18-20 W powder coated in colour of architects choice with light using UV resitant Polycarbonate diffuser. LED printed circuit board should be mounted on top of housing. System efficiancy 110 lumens / watt. LED's should be certified safe through Photobiological report for Blue Effect. Silicon encapsulated high efficient LED Driver to reduce impact of temp, voltage and current rise. Driver Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 90. surge protection 3kv, CCT should be 4000 Kelvin. The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Suspension wire length should be as per site conditions also attached with data to be Submitted with the Compliance Submission: i) Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. Data to be Submitted with the Final Submission: i) Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. ii) Mounting instruction sheets. iii) Make of LEDs/lamps, luminaire and electronic driver used (RECEPTION + Breakout area) Make:- (REIZ cat. No. Suspension Umbrella 400), Phillips, K-Lite

8

51994

6499.29

... More
Supplying Installation, Testing and commisioning of 10W LED type decorative Mirror Light with polycarbonate body , heat sink , integrated HF electronic driver, System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 80. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Make:- (REIZ cat. No. I LITE), Phillips, K-Lite

7

7346

1049.53

... More
Supplying Installation, Testing and commisioning of 10W LED type Bulkhead Light with opal polycarbonate body , heat sink , integrated HF electronic driver, System efficiancy 110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85 CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Make:- REIZ, Phillips, K-Lite

1

1073

1073.23

... More
RACEWAYS Supply and fixing of following sizes of MS Cable Raceway, 14 gauge, with all accessories as required including Bends / T Joints Clamped to fCeiling / Shafts ined with connectors, suspended from the ceiling with Suitable C Channel, G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
200mm x 40mm (3 mm thick cover)

22

18028

819.48

... More
100mm x 40mm (2 mm thick cover)

70

38290

547

... More
Junction box 450mm x 50mm (3 mm thick cover)

4

9689

2422.42

... More
Junction box 250mm x 50mm (3 mm thick cover)

25

38347

1533.88

... More
IT SITC of Rj 45 Connector Pack Of 100 Operating Temperature: -40°C To 80°C

1

7874

7874.97

... More
Supplying and fixing following modular Dual Faceplate with accessories .

38

16228

427.06

... More
Supplying and fixing following modular RJ 45 I/O for Data with accessories on the existing face plate including connections etc as per specification.

38

9957

262.03

... More
Supplying and fixing following modular RJ 11 I/O for voice with accessories on the existing face plate including connections etc as per specification.

38

9957

262.03

... More
SITC of Ceiling Mount 802.11AX 3000 Dual band 2x2MU-MIMO Ceiling AP with Cloud Controller License 1 Year Included. WiFi 6, Warranty-5 Years, New sealed pack replacement to be provided under warranty, no repair / refurbish, product will be accepted.

2

28360

14180.25

... More
CCTV SYSTEM IP DOME 2MP full real time recording 1/3" CMOS Sensor, Max resolution : 1920 x 1080, True day night function, 0.03 lux color mode and  0.02 tux B/W mode at 30 IRE  Upto 30m IR distance, 3D DNR, DWDR, Support triple streams, Onvif Profile, POE S/G compliant

6

19899

3316.56

... More
IP BULLTER 2MP full real time recording 1/3" CMOS Sensor, Max resolution : 1920 x 1080, True day night function, 0.03 lux color mode and  0.02 tux B/W mode at 30 IRE  Upto 30m IR distance, 3D DNR, DWDR, Support triple streams, Onvif Profile, POE S/G compliant, IP 66

1

3494

3494.27

... More
PAVA SYSTEM Supplying, installation, testing & commissioning of 1.5/3/6Wmetal box ceiling/wall speakers complete as required.

25

42426

1697.06

... More
Supply, installation, testing & commissioinign of 6W Volume controller, 3/4 wire, ABS Material, with 24V Override Function

1

2244

2244.38

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm

300

23220

77.4

... More
Electrical Basement Floor LIGHT AND SOCKET OUTLET POINT WIRING The rates for point wiring for all the items shall include the following : The Point Wiring shall include the wiring of light / outlets of any length from the distribution board Via Switch to the to first point (Primary Point) All the switch boxes, outlet and junction boxes shall be covered with White Polycarbonate modular cover plate. Painting of junction boxes . Embedding conduits and allied fittings in walls/floors/slabs etc. during construction and/or in chases including cutting chases and making good as necessary in the case of concealed conduit work. All accessories necessary to complete the wiring as specified. Internal wiring between accessories. Wherever flexible conduit are required GI flexible conduit of suitable size shall be used with checknut.

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (ADMIN BLOCK/STORES/PANEL ROOMS/LOBBY/ENTRANCES ETC.

-

-

-

... More
Group A

30

28414

947.16

... More
Group B

10

11077

1107.77

... More
Group C

10

13031

1303.15

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

4

5580

1395.14

... More
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(For 16 A power socket)

315

89387

283.77

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. (For office area and workstation and partition 6A switch socket RAW power point (Maximum 4 points per circuit) + office area + meeting cabins circuit wiring for light switch board point)

410

76346

186.21

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (For workstation switch socket (Maximum 2 UPS sets per circuit)

250

56715

226.86

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

26

3087

118.76

... More
TV antenna socket outlet

-

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

12

3883

323.59

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

6

186

31.07

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)

26

5434

209.03

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

44

16421

373.21

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

10

4779

477.98

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

975

46283

47.47

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group A

40

18777

469.44

... More
Group B

5

2850

570.05

... More
Group C

5

3356

671.35

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For Workstation)

26

14696

565.24

... More
Supplying and drawing following pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed steel / PVC conduit as required.

-

-

-

... More
2 pair

780

33259

42.64

... More
4 pair

-

-

-

... More
Supplying and fixing of following sizes of STEEL conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath

-

-

-

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20mm (For Data, CCTV, Telephone)

80

8499

106.24

... More
25mm (For Data, CCTV, Telephone)

225

25065

111.4

... More
32mm (For Data, CCTV, Telephone)

100

11895

118.95

... More
Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. 75 mm x 75 mm x 60 mm deep (For Data, CCTV, Telephone)

33

4223

127.98

... More
Supplying and fixing of 3 pin, 5 amp ceiling rose ISI marked on the existing junction box / wooden block including connection etc. as required.

-

-

-

... More
Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required.

6

375

62.56

... More
Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.

1

125

125.02

... More
Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor including providing and fixing phenolic laminated sheet steet cover on the fan box etc as required.etc. as required.

12

1984

165.37

... More
Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.

4

902

225.55

... More
Supplying of fresh air cum exhaust fan of heavy duty 250 V AC 50 Hz 450 mm 1400 RPM rust proof body and blades wire mesh duly erected in approved manner and marking serial number and date of erection and complete with louvers and frame Make:- Crompton, Havells, Usha

4

21114

5278.5

... More
Supply Installation, Testing and commisioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, including connection, earthing, dash fastner (hanging arrangements) etc. complete as per engineer incharge Make:- Crompton, Havells, Usha

12

25336

2111.4

... More
LIGHTING FIXTURE AND CEILING FANS / EXHAUST FANS

-

-

-

... More
Supplying Installation, Testing and commisioning of Linear Suspended light 1000/1200 mm x 50 MM W 24-30 W / Mtr powder coated in colour of architects choice with End Caps Light should be customized for interconnectivity to achieve seemless light using UV resitant Polycarbonate diffuser. LED printed circuit board should be mounted on top of housing. System efficiancy 110 lumens / watt. LED's should be certified safe through Photobiological report for Blue Effect. Silicon encapsulated high efficient LED Driver to reduce impact of temp, voltage and current rise. Driver Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85. CCT should be 4000 Kelvin. The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Suspension wire length should be as per site conditions also attached with data to be Submitted with the Compliance Submission: i) Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. Data to be Submitted with the Final Submission: i) Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. ii) Mounting instruction sheets. iii) Make of LEDs/lamps, luminaire and electronic driver used Make:- (REIZ cat. No. Suspension Rapier Mini), Phillips, K-Lite

12

46714

3892.88

... More
Supplying Installation, Testing and commisioning of 12 W LED Surface mounted (on True Ceiling) Cylindrical or Square light dimensions 140 X 65 mm with extruded aluminium body, with polyster powder coated with high U.V. and corrossion resistance , heat sink , integrated HF electronic driver System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. ( TOILETS / STORES / STAIRCASE LANDINGS Make:- (REIZ cat. No. Kan Mini), Phillips, K-Lite

4

4814

1203.55

... More
Supplying Installation, Testing and commisioning of 18 W LED Surface mounted (on True Ceiling) Cylindrical or Square light dimensions 225 X 60 mm with extruded aluminium body, with polyster powder coated with high U.V. and corrossion resistance , heat sink , integrated HF electronic driver System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 75. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. (Passage, stores, conference room etc) Make:- (REIZ cat. No. Kan Mini), Phillips, K-Lite Make:- (REIZ cat. No. Glow Mini), Phillips, K-Lite

18

31260

1736.67

... More
Supplying Installation, Testing and commisioning of Dome Suspended light dia 400 mm 18-20 W powder coated in colour of architects choice with light using UV resitant Polycarbonate diffuser. LED printed circuit board should be mounted on top of housing. System efficiancy 110 lumens / watt. LED's should be certified safe through Photobiological report for Blue Effect. Silicon encapsulated high efficient LED Driver to reduce impact of temp, voltage and current rise. Driver Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 90. surge protection 3kv, CCT should be 4000 Kelvin. The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Suspension wire length should be as per site conditions also attached with data to be Submitted with the Compliance Submission: i) Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. Data to be Submitted with the Final Submission: i) Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. ii) Mounting instruction sheets. iii) Make of LEDs/lamps, luminaire and electronic driver used (RECEPTION + Breakout area) Make:- (REIZ cat. No. Suspension Umbrella 400), Phillips, K-Lite

44

285968

6499.29

... More
Supplying Installation, Testing and commisioning of 10W LED type decorative Mirror Light with polycarbonate body , heat sink , integrated HF electronic driver, System efficiancy 100-110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 80. CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Make:- (REIZ cat. No. I LITE), Phillips, K-Lite

-

-

-

... More
Supplying Installation, Testing and commisioning of 10W LED type Bulkhead Light with opal polycarbonate body , heat sink , integrated HF electronic driver, System efficiancy 110 lumens / watt, Power factor ≥ 0.95. Light Fixtures should be certified for ≥ 70% lumen maintenance till 50,000 burning hours of usage. CRI ≥ 85 CCT should be 4000 Kelvin.The make of all LEDs used in the Tender shall be limited to Philips, lumileds, Cree, Nichia, samsung, seoul . 5 Years manufacturer’s warranty on LED's & Driver both. Make:- REIZ, Phillips, K-Lite

2

2146

1073.23

... More
RACEWAYS Supply and fixing of following sizes of MS Cable Raceway, 14 gauge, with all accessories as required including Bends / T Joints Clamped to fCeiling / Shafts ined with connectors, suspended from the ceiling with Suitable C Channel, G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
200mm x 40mm (3 mm thick cover)

12

9833

819.48

... More
100mm x 40mm (2 mm thick cover)

70

38290

547

... More
Junction box 450mm x 50mm (3 mm thick cover)

4

9689

2422.42

... More
Junction box 250mm x 50mm (3 mm thick cover)

25

38347

1533.88

... More
IT SITC of Rj 45 Connector Pack Of 100 Operating Temperature: -40°C To 80°C

1

7874

7874.97

... More
Supplying and fixing following modular Dual Faceplate with accessories .

26

11103

427.06

... More
Supplying and fixing following modular RJ 45 I/O for Data with accessories on the existing face plate including connections etc as per specification.

26

6812

262.03

... More
Supplying and fixing following modular RJ 11 I/O for voice with accessories on the existing face plate including connections etc as per specification.

26

6812

262.03

... More
SITC of Ceiling Mount 802.11AX 3000 Dual band 2x2MU-MIMO Ceiling AP with Cloud Controller License 1 Year Included. WiFi 6, Warranty-5 Years, New sealed pack replacement to be provided under warranty, no repair / refurbish, product will be accepted.

2

28360

14180.25

... More
CCTV SYSTEM IP DOME 2MP full real time recording 1/3" CMOS Sensor, Max resolution : 1920 x 1080, True day night function, 0.03 lux color mode and  0.02 tux B/W mode at 30 IRE  Upto 30m IR distance, 3D DNR, DWDR, Support triple streams, Onvif Profile, POE S/G compliant

6

19899

3316.56

... More
IP BULLTER 2MP full real time recording 1/3" CMOS Sensor, Max resolution : 1920 x 1080, True day night function, 0.03 lux color mode and  0.02 tux B/W mode at 30 IRE  Upto 30m IR distance, 3D DNR, DWDR, Support triple streams, Onvif Profile, POE S/G compliant, IP 66

1

3494

3494.37

... More
PAVA SYSTEM Supplying, installation, testing & commissioning of 1.5/3/6Wmetal box ceiling/wall speakers complete as required.

12

20364

1697.06

... More
Supply, installation, testing & commissioinign of 6W Volume controller, 3/4 wire, ABS Material, with 24V Override Function

1

2244

2244.38

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sqmm

162

12538

77.4

... More
High Side Electrical SUB-STATION (HT SIDE) Refurbhisment of 250 KVA Transformer , Includig :- Dehydration and Filteration of Transformer Oil. Cleaning & Megger Testing of all terminals. Painting of the entire body with Red-Oxide primer and suitable weather proof enamel paint.

1

50000

50000

... More
Topping up with new transformer oil

50

7500

150

... More
Dismentaling of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 120 sq. mm

-

-

-

... More
Above 120 sq. mm and upto 400 sq. mm

10

368

36.81

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 120 sq. mm

-

-

-

... More
Above 120 sq. mm and upto 400 sq. mm

10

736

73.62

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 70 sq. mm

-

-

-

... More
120 sq. mm

2

37498

18749.25

... More
Supplying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size. 3C X 70 sq. mm

-

-

-

... More
3C X 120 sq. mm

10

15249

1524.9

... More
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.

2

10025

5012.94

... More
Extra for using salt and charcoal for G.I or copper plate earth as required

2

3329

1664.94

... More
Meggar and testing of earthpits with providing test report.

10

10626

1062.6

... More
Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required.

50

28232

564.65

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia

10

15422

1542.29

... More
150 mm dia

10

23693

2369.33

... More
SUB-STATION (LT SIDE) P & F 400 Amps 36 kA 440 volt FP MCCB with heavy duty solid detachable neutral link with overcurrent short circuit and Earth Fault releases complete with IP 65 Enclosure complete with suitable size cable termination boxes.

2

68014

34007.35

... More
Dismantling of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size. Up to 25 sq.mm

200

5506

27.53

... More
From above 25 sq.mm to 400 sq.mm

200

7108

35.54

... More
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25-400 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required. MV cable laying up to 25 sq.mm in ground

200

8712

43.56

... More
MV cable laying from 25 sq.mm to 400 sq.mm in existing pipe in ground

200

11916

59.58

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.

-

-

-

... More
3 ½ x 25 sq.mm

2

669

334.88

... More
3 ½ x 35 sq.mm

2

676

338.48

... More
3½ x 50 sq.mm

2

706

353.17

... More
3½ x 70 sq.mm

2

809

404.62

... More
3½ x 95 sq.mm

4

1648

412.02

... More
3½ x 120 sq.mm

4

1849

462.47

... More
3½ x 150 sq.mm

4

2136

534.1

... More
3½ x 185 sq.mm

4

2382

595.63

... More
3½ x 240 sq.mm

4

2948

737.13

... More
3½ x 300 sq.mm

12

10079

839.96

... More
4x 10 sq.mm

20

3700

185.04

... More
4x 16 sq.mm

20

4013

200.65

... More
DISTRIBUTION BOARDS Supplying of fresh air cum exhaust fan of heavy duty 250 V AC 50 Hz 450 mm 1400 RPM rust proof body and blades wire mesh duly erected in approved manner and marking serial number and date of erection and complete with louvers and frame Make:- Crompton, Havells, Usha

4

21114

5278.5

... More
Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.

4

902

225.55

... More
Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) 6 WAY (6 + 18) DOUBLE DOOR, HORIZONTAL TYPE (For All Floor AC DB + Basement LP DB )

9

22851

2539.05

... More
8 WAY (8 + 24) DOUBLE DOOR, HORIZONTAL TYPE (Guard Room DB )

2

5465

2732.84

... More
12 WAY (12+ 36) DOUBLE DOOR, HORIZONTAL TYPE (For G+9 Floor LP DB and UPS DB)

14

48558

3468.47

... More
Supply and fixing of 5 amp to 32 amp rating 240 V "B" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required. SINGLE POLE

564

75880

134.54

... More
TRIPLE POLE AND NEUTRAL

11

9773

888.54

... More
Supply and fixing of following rating four pole 415 V isolator in the existing MCB DB ISI marked complete with connection testing and commissioning etc. as required. 40 amp

7

4054

579.26

... More
63 amp

10

6040

604.07

... More
Supply and fixing of following rating double pole (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. 25 amp (For UPS DB)

75

127977

1706.37

... More
40 amp (For LPDB + AC DB)

-

-

-

... More
Providing and fixing M.V danger board of 200 mm x 150 mm made mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red colours on front side as required.

13

1614

124.19

... More
Providing and fixing M.V danger board of 250 mm x 200 mm made mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red colours on front side as required.

5

785

157.08

... More
Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.

2

10025

5012.94

... More
Extra for using salt and charcoal for G.I or copper plate earth as required

2

3329

1664.94

... More
Supplying and laying 8 SWG copper wires ISI marked at 0.5 meter below grond level for conductor earth electrode including soldering etc. as required

20

1119

55.97

... More
Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required.

20

11293

564.65

... More
Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required.

20

10516

525.81

... More
Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required.

20

1858

92.91

... More
Providing and fixing 8 SWG ( 4 mm) dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required

800

48256

60.32

... More
Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

2

777

388.59

... More
Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required.

50

3026

60.53

... More
Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

200

11968

59.84

... More
Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

8

797

99.71

... More
Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required.

50

1653

33.06

... More
Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required.

50

4629

92.58

... More
MAIN LT PANELS + SUB DISTRIBUTION BOARDS RAW & UPS Design, manufacturing, testing at works, supply, including supervision during installation, testing & comminssioning, of floor mounting free standing totally enclosed indoor cubical extensible compartmentalized front operational vertical dust and vermin proof main LT panel fabricated out of 2 mm thick CRCA sheet steel provided with hinged detachable lockable and front and back openable comparmentalised individual chamber doors including strengthening and stiffening complete as required and as per specifications. The panel shall be powder coated after proper treatment with 8 tank process and shall be provided with following components :- Supplying, installing in position, testing and commissioning of the following Distribution Boards made of 16 gauge powder coated MS sheet steel , wall mounted/fully recessed in wall, indoor industrial type, with dust & vermin proof, hinged and lockable doors,double door design, complete with inter connecting wires of proper guage, aluminium coated copper thimbles and with the circuit identification tags. Incomer MCB to each ELCB along with earthing terminal. The DB shall be suitable for taking cable/conduit as incoming/outgoing.All MCB to be C curve unless specified otherwise

-

-

-

... More
All MCB,s shall be C curve type, except UPSDB in which MCB shall be D curve type. MAIN : HVAC & MISC

-

-

-

... More
(Proposed Location on Terrace) Incoming 1 No. 400 A FP MCCB, 36 KA service breaking capacity, complete with required extended rotary handle and suitable spreader links as required alongwith Indicating Panel The Indicating panel of incomer shall be provided with the following : Multifunction meter for V,A, KWHr, HZ, P, KVAr and equivalent to EM6436 with CT's ( 250/5A , CL1 5VA Type Resin Cast) and RS 485 communication port. 3 Nos. phase indicating lamps; backed up with MCB. One Set of ON / OFF indication lamps Bus Bar 1 No. 600 amp TPN Al Bus bar of suitable length with current density of 1.3 sq.mm/amp. Outgoing 12 Nos. 100 amp TP MCCB of 25 KA service breaking capacity & Trip setting as required ,with heavy duty solid neutral link (For VRF Outdoor Units) complete with 12 Nos. 32' A FP MCB,10 KA breaking capacity HVAC Floor DB'S. 6 Nos. 16 A FP MCB,10 KA breaking capacity Ventilation fan and Lift Well Pressurisation

-

-

-

... More
MAIN HVAC DISTRIBUTION PANEL.

1

192451

192451.08

... More
MAIN LT DISTRIBUTION PANEL. (Note : The fault withstanding capacity shall be 25 KA for one sec. Earth bus shall be part of the panel).

-

-

-

... More
BUS SECTION - I Incoming from Transformer: 400 Amps 36 kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent short circuit and Earth Fault releases with 400A 4P power contactor 1 nos Incoming from DG: 250 Amps 36 kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent short circuit and Earth Fault releases with 250 A 4p Power contactor 1 nos Metering for each Incomer Multifunction meter for PF, HZ, V, A, KVAR, KWH and equivalent to EM6400 with CT's and RS 485 communication port. Separate CT for APFCR relay in transformer incomer Indicating lamps(LED type) for transformer incomer 3 numbers Phase indicating lamps suitable for 230 V AC fittings with back up MCB. 2 Nos. indicating lamp on each incomer feeder for indicating the status of feeder with back up MCB. 1 No. TNC Breaker Control Switch. 3 Nos. indicating lamp on each incomer feeder for indicating overcurrent, short circuit, earth fault trip. Protective devices for transformer incomers The incoming MCCB shall be provided with the following protective devices:-

-

-

-

... More
Under voltage and over voltage relay with inbuilt timer for transformer incomers. Phase Reversal Protection relay. CBCT WITH ELR Separate CT's shall be provided for protective system and measuring system. CT's shall be suitable for APFCR of capacitor bank with suitable VA ( For Transformer incomer). Metering and indication for DG incomer : 3 Nos. of phase indicating lamps, Breaker ON/OFF/TRIP/'Spring Charged', 'DC control supply healthy', indicating lamps, backed up by MCB Bus Bars Electrolytic high conductivity aluminium three phase and neutral busbars rated at 600 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp.

-

-

-

... More
Outgoing: (Section-I) 160 Amps 25 kA 440 volt TP MCCB with heavy duty solid detachable neutral link overcurrent and short circuit and Earth Fault releases complete with: (UPS / + 1 Spare ) 2 nos ON / OFF indicating lamps with MCB as backup protection. 100 Amps 25 kA 440 volt TP MCCB with heavy duty solid detachable neutral link overcurrent and short circuit and Earth Fault releases complete with: (HVAC GF / + 1 Spare ) 2 nos ON / OFF indicating lamps with MCB as backup protection. 63 Amps 15 kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent and short circuit and Earth Fault releases complete with: (Lift Panel 1 & 2 /GF AC DB/ External Lighting DB / Basement Ventilation Panel / Floor LPDB's. 20 nos ON / OFF indicating lamps with MCB as backup protection.

-

-

-

... More
Capacitor Inbuilt with following:- Automatic switching "ON" and "OFF" with 8 steps automatic control relay on the control panel for 200 KVAR capacitor banks, comprising the following : - Incoming 1 No. 125 amp TP MCCB, 36 KA service breaking capacity with heavy duty solid neutral link, Digital Ammeter with CT. Phase indicating lamps each backed up with 2 amp MCB Indicating lamp in each capacitor chamber unit to indicate "ON"/"OFF" status of capacitor unit. Stepped relay(APFCR) with 8 steps (each to be of 5/15/25/50 KVAR) for automatic power factor correction having facility to change the sequence of switching 'ON' the capacitor banks as required. The program of APFCR shall be re settable to enable sequance of ON/OFF of individual bank, so that the end unit of capacitor bank is not kept idle for long.

-

-

-

... More
Outgoings 8 nos. of capacitor duty contactors. 3 Nos. 25 KVAR MPPH type capacitor banks. 3 Nos. 63 A TP MCB of 10 KA service breaking . capacity. 2 Nos. 15 KVAR MPPH type capacitor banks. 3 Nos. 5 KVAR MPPH type capacitor banks. 2 Nos. 32 A TP MCB of 10 KA breaking . capacity. 3 Nos. 20 A TP MCB of 10 KA breaking . capacity. 8 Sets of Push button stations 'RED' and 'GREEN' push buttons for manual operation of capacitors. 1 No. selector switches for changing automatic to manual operation of capacitors.(A/M) All interconnections from the bus bars to individual MCCB and MCCB to contactor and contactor to terminal blocks for Automatic Switching "ON" and OFF. Capacitor panel described as above and as per specification. Bus coupler 400A 4P Contactor suitable for Bus Bar connections and fitted with 6 NO/6NC auxiliary switch and ON/OFF indicating lights with necessary auxiliary changeover contactor. The bus coupler shall be electrically interlocked with all incoming breakers in such a way that at any one time two supplies should not get mixed up as per Drawing No. EL-07

-

-

-

... More
BUS SECTION - II Incoming from Transformer: 400 Amps 36 kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent short circuit and Earth Fault releases with 400 A 4P power contactor 1 nos Incoming from DG: 400 Amps 36 kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent short circuit and Earth Fault releases with 400 A 4P Power contactor 1 nos Metering for each Incomer Multifunction meter for PF, HZ, V, A, KVAR, KWH and equivalent to EM6400 with CT's and RS 485 communication port. Separate CT for APFCR relay in transformer incomer Indicating lamps(LED type) for transformer incomer 3 numbers Phase indicating lamps suitable for 230 V AC fittings with back up MCB. 2 Nos. indicating lamp on each incomer feeder for indicating the status of feeder with back up MCB. 3 Nos. indicating lamp on each incomer feeder for indicating overcurrent, short circuit, earth fault trip. Protective devices for transformer incomers The incoming MCCB shall be provided with the following protective devices:- Under voltage and over voltage relay with inbuilt timer for transformer incomers.

-

-

-

... More
Phase Reversal Protection relay. Separate CT's shall be provided for protective system and measuring system. CT's shall be suitable for APFCR of capacitor bank with suitable VA ( For Transformer incomer). Metering and indication for DG incomer : 3 Nos. of phase indicating lamps, Breaker ON/OFF/TRIP/'Spring Charged', 'DC control supply healthy', indicating lamps, backed up by MCB Bus Bars Electrolytic high conductivity aluminium three phase and neutral busbars rated at 500 amps, 25KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp. Outgoing: (Section-II) 400 Amps 25 kA 440 volt TP MCCB with heavy duty solid detachable neutral link overcurrent and short circuit and Earth Fault releases complete with: (HVAC PANEL) 1 nos 125 Amps 10 kA FP MCCB : (Fire Panel + MCC PANEL + 1 Spare.3 nos 63 Amps 15 kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent and short circuit and Earth Fault releases complete with: (Kitchen DB + Spare) 2 nos

-

-

-

... More
The AMF operation of DG Sets shall be carried out by power command center installed on each DG Set by DG Manufacturer however required coordination and provisions to achieve the same in coordination with PLC based Auto Load Management is included in the scope of work of Panel Manufacturer. MAIN L.T / DG / CAPACITOR PANEL described as above and all as per specification).

1

932417

932417.58

... More
Design, manufacturing, testing at works, supply, including supervision during installation, testing & comminssioning, of floor mounting free standing totally enclosed indoor cubical extensible compartmentalized front operational vertical dust and vermin proof main LT panel fabricated out of 2 mm thick CRCA sheet steel provided with hinged detachable lockable and front and back openable comparmentalised individual chamber doors including strengthening and stiffening complete as required and as per specifications. The panel shall be powder coated after proper treatment with 8 tank process and shall be provided with following components :- All MCB,s shall be C curve type, except UPSDB in which MCB shall be D curve type. 80 KVA UPS PANEL (Proposed Location in Basement) Incoming 1 No.160 A FP MCCB, 36 KA service breaking capacity, complete with required extended rotary handle and suitable spreader links as required alongwith Indicating Panel

-

-

-

... More
The Indicating panel of incomer shall be provided with the following : Multifunction meter for V,A, KWHr, HZ, P, KVAr and equivalent to EM6436 with CT's ( 250/5A , CL1 5VA Type Resin Cast) and RS 485 communication port. 3 Nos. phase indicating lamps; backed up with MCB. One Set of ON / OFF indication lamps Bus Bar 1 No. 300 amp TPN Al Bus bar of suitable length with current density of 1.3 sq.mm/amp. Outgoing All MCCB outgoing feeders shall be provided with ON indication lamp. 12 Nos. 40 amp FP MCB of 10 KA service breaking capacity & Trip setting as required ,with heavy duty solid neutral link complete as per requirement. (Floor DB) 80 KVA UPS PANEL

1

40772

40772.07

... More
Supply, installation and testing of 160 A Four pole MCCB with box suitable for cable connection. (For 80KVA UPS)

1

29934

29934.29

... More
Supply, installation and testing of 63 A Four pole MCB with box suitable for cable connection. (For 4th, 5th & 6th Floor)

3

10469

3489.94

... More
Supply, installation,testing and commissioning of EXIT light self contained 11W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.

10

48831

4883.18

... More
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.

2

1979

989.67

... More
Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963.

2

1266

633.06

... More
MAIN CABLES & SUBMAINS Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25-400 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. MV cable laying from 120 sq.mm to 400 sq.mm in ground

150

24726

164.84

... More
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25-400 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required. MV cable laying up to 25 sq.mm in ground

1505

65557

43.56

... More
MV cable laying from 25 sq.mm to 400 sq.mm in existing pipe in ground

490

29194

59.58

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.

-

-

-

... More
3½ x 50 sq.mm

2

706

353.17

... More
3½ x 95 sq.mm

2

824

412.02

... More
3½ x 150 sq.mm

4

2136

534.1

... More
3½ x 300 sq.mm

20

16799

839.96

... More
4x 10 sq.mm

28

5181

185.04

... More
4x 16 sq.mm

20

4013

200.65

... More
4x 35 sq.mm

22

-

-

... More
4x 6 sq.mm

4

705

176.32

... More
4x 4 sq.mm

20

3431

171.58

... More
BASIC RATES FOR MATERIALS PVC INSULATED ALUMINUM CONDUCTOR

-

-

-

... More
50 sq.mm 3 1/2 core PVC Armoured Cables ISI Marked (UPS)

50

16540

330.8

... More
95 sq.mm 3 1/2 core PVC Armoured Cables ISI Marked (Fire + MCC)

120

66904

557.54

... More
150 sq.mm 3 1/2 core PVC Armoured Cables ISI Marked (For HVAC)

120

98944

824.54

... More
300 sq.mm 3 1/2 core PVC Armoured Cables ISI Marked

200

316072

1580.36

... More
6 Sq.mm 4 core PVC Armoured Cables ISI Marked (10 Nos HVAC DB +2 Nos Lift)

600

75384

125.64

... More
10 sq.mm 4 core PVC Armoured Cables ISI Marked (Lift presization + Guard Room DB)

60

9423

157.05

... More
16 sq.mm 4 core PVC Armoured Cables ISI Marked (For 6 Nos VRF)

400

68320

170.8

... More
35 sq.mm 4 core PVC Armoured Cables ISI Marked (11 Nos LPDB)

570

165054

289.57

... More
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor. (UPS Panel To UPS DB)

495

142258

287.39

... More
CABLE TRAYS Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

120

129699

1080.83

... More
600 mm width X 50 mm depth X 2.0 mm thickness

50

74700

1494.01

... More
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the floor with grouting, applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.

100

9619

96.19

... More
EXTERNAL LIGHTING Providing and fixing of 50W LED post top light made up of aluminum housing with non yellowing UV stabilized translucent acrylic diffuser. The luminaire comes with a luminous flux of 5000+ lm(at 3000K) with BA-120deg, color temperatures of 3000K, SDCM≤3 , CRI80 and the LED lifespan of L70 B10@60000 hrs. The ingress protection is IP 65 and Impact resistance is IK07. The luminaire is suitable for mounting on 50mm dia OD pipe.The integral constant current driver comes with power factor greater than 0.98 and the Total Harmonic Distortion less than 10% with the operating efficiency greater than 85% and a surge protection of 6KV. The LED's are RoHS complied. The driver input voltage is 230-240Vac at 50-60Hz, operating voltage of 100-277Vac and operating temperature of -15˚ ~ +50˚C with CE certified and BIS approved. (The Light shall be Eq. to REIZ cat no.-PATHWAY POLE TOP WHEEL LED 50W 3000K BLACK IP 65) Including 500mm long 50 mm Dia G.I. Pipe with suitable base plate Make:- REIZ, K-LITE, PHILIPS

4

50697

12674.44

... More
Providing and fixing of 100 Watt Flood Light 3000 K IP 65 Made from Extruded Alluminium and pressed SS Sheet. Extruded Alluminium for better heat sink and powder coated for corrosion resistance. Strain relief cable clamp with terminal block. THD,10%, PF 0.95. IK 08. CRI80. Current Ripple 10%. Angle 45D. A. General Requirement:- i. All fixtures shall be designed so as to have lumen maintenance of at least 70% after 50,000 hours (L70) and 90% after 10,000 hours (L90) at an ambient temperature of 50°C in outdoor use for LED luminaires. ii). All outdoor luminaires shall be designed for IP65 (and IP67 for underwater luminaires) ingress protection to prevent ingress of water and dust. iii). The make of all LEDs used in the Tender shall be limited to lumileds, Cree, Nichia, samsung, seoul or Osram. iv). Luminaire efficacy to be 130 lumens/W B. Electrical Specification:- i). Properties of all proposed luminaire products for the following criteria shall be as per the table below. ii. Voltage range or rating: on single phase for 4 hrs 100 to 300 vac iii. Luminaire efficiency at 5700/6000K (For Outdoor Arena Applications) iv. Frequency range of input power for all tests Rated frequency 50 +- 5 hz v. Driver efficiency 94% @ 240vac vi. Total input wattage to the fittings including driver losses above or below the rated power, xi. Power factor 0.90 vii. a. Colour Rendering Index for outdoor arena Lighting 80 viii.Life expectancy (for 70% lumen maintenance) ix. Guarantee (for all parts of the system: LEDs/lamps, luminaire, dimmers and switches, supports and poles, etc.) 5 years x. Surge Protection for outdoor luminaires: differential level 6kv xi. Electrical insulation class to be class 1. xii. Total harmonic distortion 10% xiii. Output current ripple to be 5% pp xiv. Operating temperature –40 to +50 c xv. Variation in illumination level 3% in input voltage range from 180 V AC to 250 V AC C. Data to be Submitted with the Compliance Submission: i. Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. D. Data to be Submitted with the Final Submission: Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. (The Light shall be Eq. to REIZ cat no. REIZ 100 W Projector Sporty) Make:- REIZ, K-LITE, PHILIPS

8

128696

16087.03

... More
Providing and fixing of 150 Watt Flood Light 3000 K IP 65 Made from Extruded Alluminium and pressed SS Sheet. Extruded Alluminium for better heat sink and powder coated for corrosion resistance. Strain relief cable clamp with terminal block. THD,10%, PF 0.95. IK 08. CRI80. Current Ripple 10%. Angle 25D. A. General Requirement:- i. All fixtures shall be designed so as to have lumen maintenance of at least 70% after 50,000 hours (L70) and 90% after 10,000 hours (L90) at an ambient temperature of 50°C in outdoor use for LED luminaires. ii). All outdoor luminaires shall be designed for IP65 (and IP67 for underwater luminaires) ingress protection to prevent ingress of water and dust. iii). The make of all LEDs used in the Tender shall be limited to lumileds, Cree, Nichia, samsung, seoul or Osram. iv). Luminaire efficacy to be 130 lumens/W B. Electrical Specification:- i). Properties of all proposed luminaire products for the following criteria shall be as per the table below. ii. Voltage range or rating: on single phase for 4 hrs 100 to 300 vac iii. Luminaire efficiency at 5700/6000K (For Outdoor Arena Applications) iv. Frequency range of input power for all tests Rated frequency 50 +- 5 hz v. Driver efficiency 94% @ 240vac vi. Total input wattage to the fittings including driver losses above or below the rated power, xi. Power factor 0.90 vii. a. Colour Rendering Index for outdoor arena Lighting 80 viii.Life expectancy (for 70% lumen maintenance) ix. Guarantee (for all parts of the system: LEDs/lamps, luminaire, dimmers and switches, supports and poles, etc.) 5 years x. Surge Protection for outdoor luminaires: differential level 6kv xi. Electrical insulation class to be class 1. xii. Total harmonic distortion 10% xiii. Output current ripple to be 5% pp xiv. Operating temperature –40 to +50 c xv. Variation in illumination level 3% in input voltage range from 180 V AC to 250 V AC C. Data to be Submitted with the Compliance Submission: i. Simulations and calculation of achievement of luminosity and lighting power density (LPD) as per specifications. D. Data to be Submitted with the Final Submission: Relevant LEDs/lamps and luminaire data sheets and type test certificates indicating compliance to the technical specifications/standards. (The Light shall be Eq. to REIZ cat no. REIZ 100 W Projector Sporty) Make:- REIZ, K-LITE, PHILIPS

20

395435

19771.78

... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre

20

74470

3723.51

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. (Note also to be used for making base poles for gate & boundary lights) 40 mm

20

11979

598.95

... More
Providing & erecting Conical Lighting Pole 3.6 m high (clear height) 3mm thick continously tapered designed to wind speed in compliance with IS 875 Part 3 :1987. Pole construction shall made of MS Pipe of high strength and corrosion resistance in various atmospheric conditions. The pole of size top dia 48mm X bottom dia 140mm X hight 3600MM emerges from the □300 x 16 mm thick base plate. The pole is built with weather proof control box enclosure with a service door of 330mm H x 75mm at 1000mm H above the base plate shall be provided with safety rope. The Single arm pole is integrated with high bright LED light source of 1 x 90W LED Light module on the 1000 mm long, horizontal single arm bracket. Having the Correlated Color Temperature in 3000K and Type II distribution. LED module is integrated with High power LED, CRI: 80, Life time of Burning hours is L70/B10 60,000 hrs, SDCM is less than or equal to 3 step Macadam, LED efficacy is min 124 lm/W, RoHS certified and LED Light module is provided with clear Polycarbonate optical cover. The 90W LED module is provided with Ingress protection IP65 and Impact protection IK08. The integral constant current driver comes with power factor of greater than 0.9 and the Total Harmonic Distortion less than 10% with the operating efficiency above of 85% and a surge protection of 6KV. The driver input voltage is 230Vac at 50-60Hz single phase ac supply, operating voltage of 100-277Vac and operating temperature of -40˚ ~ +50˚C. The mounting plate shall be provided with elongated holes (48 x 24) for alignment of the pole to suit 500mm long M20 Bolt of Grade 4.6 at CC 215. The inbuilt junction box contains 6A MCB of reputed make with built-in control box with service door including safety rope. The control gear tray is prewired with 2.5 sq.mm cable, MCB and terminal connectors for loop-in/ loop-out arrangement. The surface of the pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phospate primer and finished using environmentally stable polyurethane based paint. The Pole shall be provided with Graphite grey/ Anthracite grey/ Jet black as standard colour options. (The Light shall be Eq. to REIZ cat no.-RS4FMB000005540A000.) (Single Arm Bracket Including 90W LED Fixtures REIZ cat no.- POLE TOP WAYFARER LED 90W 3000K SILVER IP 65 ) Make:- REIZ, K-LITE, PHILIPS

20

540527

27026.36

... More
3 x 2.5 Sq.mm Cu.Ar. Cable

500

85045

170.09

... More
ELV Supply of Passive Components for Active Data on CAT6 SITC of 24 Port Patch panels CAT6 (1U with rear wire manager) 45˚silver-plated IDCs (Loaded) (insulation displacement connection) for secure, reliable gas-tight connections

15

108287

7219.19

... More
SITC of Rj 45 Connector Pack Of 100 Operating Temperature: -40°C To 80°C

1

7874

7874.97

... More
SITC of 15U (W 600mm/ D 600mm) wall mount with front glass door and side panels with lock & key (load bearing capacity of 25Kgs) Accessories of rack Usiable depth of 500mm Fan Housing Unit with 2 fans Cable manager 1U Horizontal - 3 in each Cantilever tray AC main Channel 06 points 5 Amp (PDU) Earthing Kit Mounting Hardware (Pack of 10)

6

51870

8645.04

... More
Supply, installation testing and commissioning of 19" Rack Mountable Un-Managed Switch 16 x 10/100/1000 Mbps POE+ ethernet ports, 8x10/100/1000 Ethernet Ports 190W (POE Budget),48 GBPS Switching Capacity, 192 KB Packet buffer Memory, 10KB Jumbo Frame support Operating Temp 0 Deg to 45 Deg Celsius, Warranty-3 Years, New sealed pack replacement to be provided under warranty, no repair / refurbish, product will be accepted.

5

74442

14888.57

... More
SITC of Closed Server Rack 32U- with Sidepanel, Perforrated Doors, Dimensions should be minimum of 600mm (W) x 600mm (D), All mounting / cable management accessories & Castors). - Not exceeding 1600mm in height (For Server room - Servers, Voice, Interface PC's, Servers) 2 Nos. of 1U power distribution box, with 10 x IEC - C13 sockets & with 32Amp MCB- terminating on a IP56 power sockets - Vertical 1 No. Horizontal PDU with 5/15Amp Universal Sockets with 32Amp MCB Grounding / Bonding kit 42U Mounting Hardware (Pack of 10) x 10 Cantilever tray & Keyboard Tray Stationary Shelf - full depth (2Nos.)

1

39475

39475.9

... More
Supply, installation testing and commissioning of 19" Rack Mountable L2, Smart Managed Switch 24 x 10/100/1000 Mbps ethernet ports, 2 Dedicated SFP Ports,52GBPS Switching Capacity, 9K Jumbo Frame Support, 16K Mac address, DHCP Client, Static Routing, SNMP v1,V2c,V3, RMON1,2,3,9. Operating temp 0 deg to 50 deg Celsius OEM Warranty-6 Years, New sealed pack replacement to be provided under warranty, no repair / refurbish, product will be accepted.

12

407644

33970.39

... More
Supply, installation testing and commissioning of Rack/ Desktop/ Wall Mountable Un-Managed Switch 8X10/100/1000 Mbps POE+ , Ports, Fan less 123W (POE Budget), 16 GBPS Switching Capacity, 192 KB Buffer Size, jumbo frame support Operating Temp-0 Deg to 40Deg Celsius, Warranty-6 Years, New sealed pack replacement to be provided under warranty, no repair / refurbish, product will be accepted.

7

91087

13012.52

... More
EPABX Supply, installation, testing & commissioning of Operator position - Digital phone with LCD (150*48 dot matrix), Fixed key SPK, HLD, MUTE, MIC, VOLUME UP/DOWN, TRANSFER, Freely programmable keys - 20 Nos, Two way full duplex speaker phone.

2

22466

11233.05

... More
Supply, installation, testing & commissioning of Soft IP Phone (BYOD) with mimimum 20 BLF self labelling keys, Call history (Incoming, Outgoing, Missed), Extension number display, Two way video communication, Works on internal WiFi network and Outside data network. (For Windows, Android, iOS platform)

13

48079

3698.45

... More
Supply, installation, testing & commissioning of Digital phone instruments LCD (3 Line display), SPK, HLD, MUTE, MIC, TRANSFER, Freely programmable keys - 5 Nos, Two way speaker phone.

7

57417

8202.51

... More
Supply, installation, testing & commissioning of IP Conference phone with speaker 6W and 4 Multi directional microphones

1

37093

37093.34

... More
Supply, installation, testing & commissioning of MDF Box MS Powder coated with lock & key equipped with 300 Pair krone 10x2 disconnection modules with SS Back Mount Frame

1

9533

9533.59

... More
Supply, installation, testing & commissioning of MDF Box MS Powder coated with lock & key equipped with 50 Pair krone 10x2 disconnection modules with SS Back Mount Frame

12

39544

3295.36

... More
Supply, laying, testing & commissioning of Single Pair 0.51mm Cu Conductor Jumper Wire

1200

6180

5.15

... More
CCTV SYSTEM Supply, installation, testing & commissioning of Embeded Linux operating sysytem, 32-Channel NVRs, with multiple hard drive options plus the ability to expand to up to 64 TB of internal storage, Up to 8 channels at 1080p, or 4 channels at 4 MP, or 2 channels at 8 MP H.265/H.264 decoding, Play; Pause; Stop; Rewind; Fast play; Slow play; Next File; Previous File; Next Camera; Previous Camera; Full Screen; Backup selection; Digital Zoom, supported protocals HTTP, TCP/IP, IPv4/IPv6, UPnP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, DDNS, IP Search, P2P, 1 RJ-45 port (10/100/1000 Mbps) High Performance, High Reliability IP Recorder.  — Continuously records with 320 Mbps incoming bandwidth. Support Up to 32 IP Camera, RAID0, RAID1, RAID5, RAID6, RAID10.

2

39749

19874.54

... More
Supply, installation, testing & commissioning of Surveillance Hard Disk Drive of capacity 4 TB

4

61048

15262.11

... More
PA SYSTEM SITC of 16 zone Voice Alarm controller for easy operation, its own PTT Mictrophone, simple integration with Fire Alarm Panels (15 Zone wise + All zone) to activate EVAC/ALERT pre-recorded messages, Emergency button for Pre-recorded Message, Built-in Media Player with USB reader (MP3/WAV/FLAC), Bluetooth V5.0, FM Radio functions, SD CARD, 1 line input, provides 16 broadcast zone output function, the peak power of zone is 1000W, and the total power of the all 16 zones is 2000W,19” 2U rack mount type The Voice alarm controller should also have the following functions:Line Input:- 300mV; PTT Microphone Frequency Response:- 20Hz to 20 KHz; Line Output:- 1.2V; Frequency Response:- 20Hz~20KHz; Signal Noise Ratio(S/R):- 80 Db; Total Harmonic Distortion(THD):- 0.01%

1

168167

168167.48

... More
SITC of 16 Button Call Station with Zoning and Paging Microphone with Emergency Pre-recorded message should also have the following functions:Signal Input frequency:100Hz~15KHz ; Communication :RS485 mode

1

31743

31743.1

... More
Supply, installation, testing & commissioning of Class D amplifier 500 watts Frequency response: 60 Hz to 15 khz (+1/3db), Inputs :XLR & phone jack , Input 1, Input 2-4, Impendence :20kΩ, Sensitivity : 1 V balanced , S/N : 85 dB complete in all respect

1

43416

43416.87

... More
Supply, Installation, testing & commissioning of Bluetooth / SD card /AM/FM /USB player

-

-

-

... More
Supply, Installation, Testing & Commissioning of Distribution rack and housing  for amplifier, power supply unit mounting,  and all connection.

-

-

-

... More
ELV CABLING SITC of STP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

2

16041

8020.62

... More
SITC of 50 pair unarmoured Riser Cable

400

190672

476.68

... More
SITC of 10 Pair jelly filled telephone armoured Cable

100

33807

338.07

... More
SITC of 6 core OFC armoured cable single mode

100

8230

82.3

... More
External Plumbing System SUBHEAD I : EXTERNAL SEWER, DRAINAGE PIPING MANHOLES ETC. Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil up to 1.50 m depth

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

210

68390

325.67

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).

10

1909

190.91

... More
Providing laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.

-

-

-

... More
100 mm diameter

2

646

323

... More
150 mm diameter

2

942

471

... More
200 mm diameter

2

1626

813

... More
250 mm diameter

50

56000

1120

... More
300 mm diameter

50

71700

1434

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipes including bed concrete as per standard design.

-

-

-

... More
150 mm diameter

2

1624

812

... More
200 mm diameter

2

2197

1098.56

... More
250 mm diameter

2

2540

1270.37

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of SW pipes including bed concrete as per standard design. 300 mm diameter

50

40610

812.2

... More
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)

-

-

-

... More
150 mm dia RCC pipe

15

7745

516.37

... More
250 mm dia RCC pipe

25

20253

810.15

... More
300 mm dia RCC pipe

100

80233

802.33

... More
450 mm dia RCC pipe

15

35284

2352.32

... More
Providing and laying in position cement concrete of grade excluding the cost of centering and shuttering - all work up to plinth level 1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40 mm nominal size)

25

90772

3630.91

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 fine sand) including 500 x 450 mm (heavy duty) precast RCC horizontal grating with frame complete as per standard design : : with FPS bricks

6

2939

489.94

... More
Constructing brick masonry manhole with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not less than 38 kg (wt. of cover 23 kg and wt. of frame 15 kg)

15

113659

7577.33

... More
Extra for depth for manhole with F.P.S. bricks size 90 X 80 cm

2

11557

5778.59

... More
Constructing brick masonry circular manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885

4

35906

8976.57

... More
Extra depth for circular type manhole 0.91 m internal dia (at bottom) beyond 0.91 m to 1.67 m : With Sewer bricks conforming IS : 4885

4

19850

4962.68

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885

-

-

-

... More
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :

-

-

-

... More
With Sewer bricks conforming IS : 4885

1

6395

6395.16

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

120

37906

315.89

... More
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4.5 KG & FRAME MIN.2.7 KG ) 180x150 mm size P type With FPS bricks

6

12261

2043.64

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement cincrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete for pipes 100 to 230mm dia.

1

413

413.79

... More
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

4

157

39.33

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

8

1374

171.82

... More
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100mm Dia

248

11638

46.93

... More
SUBHEAD-II(A): Rain Water Harvesting Pit DESILTING CHAMBER Earth work In excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as per as 10 sq.m on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil

8.4

1596

190

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m.

5.6

669

119.48

... More
Extra for every additional lift of 1.5 m or part there of in: All kinds of soil.

3.65

219

60.18

... More
Providing and laying in position cement cncrete of specified grade excluding the cost of centring and shuttering - all work upto plinth level. 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

0.3

1261

4205.3

... More
Centring and shuttering including strutting, proppintg etc. and removal of form for: Suspended floors,roofs, landings, balconies and access platform.

2

1533

766.55

... More
Edges of slabs and breaks in floors and walls, Under 20 cm wide

6

1091

181.9

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo Mechanically Treated bars.

22

3177

144.42

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level.

2.3

11398

4955.7

... More
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand)

3.25

15309

4710.68

... More
12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand).

15

2416

161.12

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete: 200 mm diameter

3

2439

813

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.

0.27

221

820.17

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450mm internal dimensions

2

2201

1100.96

... More
RECHARGE PIT (1 No.) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 Sq.M on plan) including dressing of sides and ramming ob bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, withen a lead of 50m All kinds of soil

48

9120

190

... More
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil

22.6

1360

60.18

... More
Ordinary or hard rock

15.05

1619

107.6

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m.

25.65

3370

131.4

... More
Providing and laying in position cement cncrete of specified grade excluding the cost of centring and shuttering - all work upto plinth level. 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

0.9

3784

4205.3

... More
Centring and shuttering including strutting, proppintg etc. and removal of form for:Suspended floors,roofs, landings, balconies and access platform.

10.75

8240

766.55

... More
Edges of slabs and breaks in floors and walls,

-

-

-

... More
Under 20 cm wide

12.56

2284

181.9

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.

-

-

-

... More
Thermo Mechanically Treated bars.

160

12012

75.08

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level.

1.48

9540

6446.45

... More
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand)

14

73740

5267.2

... More
12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand).

30

4833

161.12

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete: 200 mm diameter

3

2439

813

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.

1.5

388

258.71

... More
Boring/drilling bore well of required dia for Casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia.

20

13771

688.55

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia.

20

24733

1236.68

... More
Supplying, filling, spreading & leveling gravels of size range 4.6 mm to 4.8 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4.9

7115

1452.17

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4.9

6751

1377.88

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450mm internal dimensions

2

2201

1100.96

... More
Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete.

9.42

7919

840.67

... More
Providing & fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS:13592 Tyape A included jointing with seal ring conforning to IS:5382 leaving 10 mm gap for thermal expansion. (i)Single socketed pipes. 110 mm diameter

90

45041

500.46

... More
Total estimate for plus one pit

1

283803

283803.72

... More
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. Make : Hindware, Jaquar, Roca , base rate minimum 15000 Rs. Selected as per engineer in charge

-

-

-

... More
Ground Floor

6

114124

19020.71

... More
First Floor

6

114124

19020.71

... More
Second Floor

6

114124

19020.71

... More
third Floor

8

152165

19020.71

... More
Seventh Floor

8

152165

19020.71

... More
Eirth Floor

8

152165

19020.71

... More
Ninth Floor

8

152165

19020.71

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Standard ( 550x400mm) size basinMake : Hindware, Jaquar, Roca , base rate minimum 9800 Rs. Selected as per engineer in charge

-

-

-

... More
Ground Floor

5

24848

4969.6

... More
First Floor

6

29817

4969.6

... More
Second Floor

6

29817

4969.6

... More
third Floor

7

34787

4969.6

... More
Seventh Floor

7

34787

4969.6

... More
Eirth Floor

7

34787

4969.6

... More
Ninth Floor

7

34787

4969.6

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption) with division plate of parryware make having cat no C0571 or equivalent, having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

-

-

-

... More
Ground Floor

2

30424

15212.3

... More
First Floor

2

30424

15212.3

... More
Second Floor

2

30424

15212.3

... More
third Floor

2

30424

15212.3

... More
Seventh Floor

2

30424

15212.3

... More
Eirth Floor

2

30424

15212.3

... More
Ninth Floor

2

30424

15212.3

... More
Supplying and fixing battery operated sensor concealed type flushing valve for urinals complete with installation box, control cock, batteries etc complete as per PH specification and direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

2

20766

10383

... More
First Floor

2

20766

10383

... More
Second Floor

2

20766

10383

... More
third Floor

2

20766

10383

... More
Seventh Floor

2

20766

10383

... More
Eirth Floor

2

20766

10383

... More
Ninth Floor

2

20766

10383

... More
Supplying, Fittings & Fixing with all labour, T&P as per specification, the following Brass / CP(Jaquar) /G.M. fittings at appropriate locations along the pipe lines at all floors and at all heights of approved make confirming to relevent IS specification. etc.complete in all respect as per direction of the Engineer in charge.

-

-

-

... More
(c) 15 mm dia CP Angle stop cock Ground Floor

31

29967

966.7

... More
First Floor

36

34801

966.7

... More
Second Floor

36

34801

966.7

... More
third Floor

36

34801

966.7

... More
Seventh Floor

36

34801

966.7

... More
Eirth Floor

36

34801

966.7

... More
Ninth Floor

36

34801

966.7

... More
(e) 15 mm dia C.P. Pillar cock Ground Floor

6

8879

1479.9

... More
First Floor

7

10359

1479.9

... More
Second Floor

7

10359

1479.9

... More
third Floor

7

10359

1479.9

... More
Seventh Floor

7

10359

1479.9

... More
Eirth Floor

7

10359

1479.9

... More
Ninth Floor

7

10359

1479.9

... More
(h) CP Soap holder Ground Floor

6

1783

297.3

... More
First Floor

7

2081

297.3

... More
Second Floor

7

2081

297.3

... More
third Floor

7

2081

297.3

... More
Seventh Floor

7

2081

297.3

... More
Eirth Floor

7

2081

297.3

... More
Ninth Floor

7

2081

297.3

... More
(j) 15 mm dia C.P. Towel Ring Ground Floor

6

3769

628.2

... More
First Floor

7

4397

628.2

... More
Second Floor

7

4397

628.2

... More
third Floor

7

4397

628.2

... More
Seventh Floor

7

4397

628.2

... More
Eirth Floor

7

4397

628.2

... More
Ninth Floor

7

4397

628.2

... More
(m)32 mm dia C.P. waste Ground Floor

6

3011

501.9

... More
First Floor

7

3513

501.9

... More
Second Floor

7

3513

501.9

... More
third Floor

7

3513

501.9

... More
Seventh Floor

7

3513

501.9

... More
Eirth Floor

7

3513

501.9

... More
Ninth Floor

7

3513

501.9

... More
Supplying ,fittingand fixing with all labour and T & P 4mm thick bevelled edge sheet glass Mirror of relevant IS specification to the brick concrete wall with full sheet hard board and CP down shaped screw on wooden /PVC plug etc. complete as per direction of the Engineer in charge.Bath Room Mirror 600 MM x 600 MM

-

-

-

... More
Ground Floor

6

9994

1665.8

... More
First Floor

7

11660

1665.8

... More
Second Floor

7

11660

1665.8

... More
third Floor

7

11660

1665.8

... More
Seventh Floor

7

11660

1665.8

... More
Eirth Floor

7

11660

1665.8

... More
Ninth Floor

7

11660

1665.8

... More
Supplying all materials, labour, T&P and fixing Health faucet of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

-

-

-

... More
Ground Floor

7

9229

1318.5

... More
First Floor

8

10548

1318.5

... More
Second Floor

8

10548

1318.5

... More
third Floor

8

10548

1318.5

... More
Seventh Floor

8

10548

1318.5

... More
Eirth Floor

8

10548

1318.5

... More
Ninth Floor

8

10548

1318.5

... More
Supplying all materials, labour, T&P and fixing toilet paper holder of Jaquar Cat. No.-ACN-1153 or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.

-

-

-

... More
Ground Floor

7

6950

992.9

... More
First Floor

8

7943

992.9

... More
Second Floor

8

7943

992.9

... More
third Floor

8

7943

992.9

... More
Seventh Floor

8

7943

992.9

... More
Eirth Floor

8

7943

992.9

... More
Ninth Floor

8

7943

992.9

... More
Providing & Fixing of Grab bar 600 mm of non slipping grip as per standard specification of use in disabled toilet complete with brackets suitable for wall installation as per approved sample complete in all respect.(Make Hindware, Parryware, Cera)

-

-

-

... More
Ground Floor

1

5084

5084.9

... More
First Floor

1

5084

5084.9

... More
Second Floor

1

5084

5084.9

... More
third Floor

1

5084

5084.9

... More
Seventh Floor

1

5084

5084.9

... More
Eirth Floor

1

5084

5084.9

... More
Ninth Floor

1

5084

5084.9

... More
Providing and Fixing Grab bar 90 degree right of non slipping grip, fixed to PVC cleats with C.P. brass screws wherever required with approved make & quality and as per the directions and to the satisfaction of Engineer-in-charge. (Make-Hindware,Parryware,Cera)

-

-

-

... More
Ground Floor

1

7326

7326.5

... More
First Floor

1

7326

7326.5

... More
Second Floor

1

7326

7326.5

... More
third Floor

1

7326

7326.5

... More
Seventh Floor

1

7326

7326.5

... More
Eirth Floor

1

7326

7326.5

... More
Ninth Floor

1

7326

7326.5

... More
Providing and Fixing WC Pan Connector, fixed to PVC cleats with C.P. brass screws wherever required with approved make & quality and as per the directions and to the satisfaction of Engineer-in-charge. (Make-Hindware,Parryware,Cera)

-

-

-

... More
Ground Floor

7

966

138.1

... More
First Floor

8

1104

138.1

... More
Second Floor

8

1104

138.1

... More
third Floor

8

1104

138.1

... More
Seventh Floor

8

1104

138.1

... More
Eirth Floor

8

1104

138.1

... More
Ninth Floor

8

1104

138.1

... More
Sub Head 2: Water Supply Supplying, Fittings & Fixing in floors and at all heights the CPVC pipes of following sizes with necessary fittings to the walls including concealing the pipes with cutting grooves to the brick & concrete walls and making good to the grooves/damages after laying and fixing the pipes, with C.M. (1:4) etc. complete in all respect as pe rthe direction of the Engineer in charge. (Concealed)

-

-

-

... More
(a)15 mm dia CPVC Pipe Ground Floor

5

1942

388.55

... More
First Floor

5

1982

396.53

... More
Second Floor

5

2022

404.51

... More
third Floor

5

2062

412.48

... More
Seventh Floor

5

2222

444.4

... More
Eirth Floor

5

2261

452.38

... More
Ninth Floor

5

2301

460.36

... More
( b) 20 mm dia CPVC Pipe Ground Floor

30

13357

445.26

... More
First Floor

35

15863

453.24

... More
Second Floor

35

16142

461.22

... More
third Floor

35

16422

469.2

... More
Seventh Floor

35

17538

501.11

... More
Eirth Floor

35

17818

509.09

... More
Ninth Floor

35

18097

517.07

... More
( c) 25 mm dia CPVC Pipe Ground Floor

18

9727

540.4

... More
First Floor

18

9870

548.38

... More
Second Floor

18

10014

556.36

... More
third Floor

18

10158

564.34

... More
Seventh Floor

18

10732

596.26

... More
Eirth Floor

18

10876

604.23

... More
Ninth Floor

18

11019

612.21

... More
( d) 32 mm dia CPVC Pipe Ground Floor

12

8289

690.76

... More
First Floor

12

8384

698.74

... More
Second Floor

12

8480

706.72

... More
third Floor

12

8576

714.7

... More
Seventh Floor

12

8959

746.62

... More
Eirth Floor

12

9055

754.6

... More
Ninth Floor

12

9150

762.57

... More
Supplying all materials, labours, T&P and fitting and fixing of the following size of CPVC pipe confirming to IS 15778 certification mark with socket and screw joints in walls and floors including supplying of required number of fittings of approved make including cutting threads to pipes and pipes to length, including wastage,etc for fitting to the walls with supply of holder ats, clamps, fixing wooden plugs in walls, including testing of pipe line for water tightness complete as per IS specification including cost, conveyance and taxes of all materials all complete as per PH specification and direction of Engineer-in-charge.(Non Concealed) 25mm dia

-

-

-

... More
Ground Floor

2

705

352.64

... More
First Floor

2

721

360.62

... More
Second Floor

2

737

368.6

... More
third Floor

2

753

376.57

... More
Seventh Floor

2

816

408.49

... More
Eirth Floor

2

832

416.47

... More
Ninth Floor

2

848

424.45

... More
32mm dia

-

-

-

... More
Ground Floor

2

1006

503

... More
First Floor

2

1021

510.98

... More
Second Floor

2

1037

518.96

... More
third Floor

2

1053

526.93

... More
Seventh Floor

2

1117

558.85

... More
Eirth Floor

2

1133

566.83

... More
Ninth Floor

2

1149

574.81

... More
40mm dia

-

-

-

... More
Ground Floor

2

1314

657.44

... More
First Floor

2

1330

665.41

... More
Second Floor

2

1346

673.39

... More
third Floor

2

1362

681.37

... More
Seventh Floor

2

1426

713.29

... More
Eirth Floor

2

1442

721.27

... More
Ninth Floor

2

1458

729.25

... More
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. (Shaft Pipe - Riser and Downcomers) Internal work -Exposed on Wall

-

-

-

... More
25 mm nominal outer dia pipes

30

11656

388.54

... More
32 mm nominal outer dia pipes

55

29639

538.9

... More
40 mm nominal outer dia pipes

65

45067

693.34

... More
50 mm nominal outer dia pipes

145

156434

1078.86

... More
Supplying all materials, labour, T&P, fitting & fixing of different size Brass / GM Ball Valve of approved make including supply of all necessary jointing materials such as red lead paint, yarns etc. including cost, conveyance & taxes of all materials, T&P etc. all complete as per P.H. specification and direction of the Engineer-in-charge.20mm Dia

-

-

-

... More
Ground Floor

1

854

854.25

... More
First Floor

2

1722

861.39

... More
Second Floor

2

1737

868.54

... More
third Floor

2

1751

875.68

... More
Seventh Floor

2

1089

544.64

... More
Eirth Floor

2

1103

551.79

... More
Ninth Floor

2

1117

558.93

... More
25mm Dia

-

-

-

... More
Ground Floor

1

1222

1222.42

... More
First Floor

1

1229

1229.57

... More
Second Floor

1

1236

1236.71

... More
third Floor

1

1243

1243.85

... More
Seventh Floor

1

1272

1272.42

... More
Eirth Floor

1

1279

1279.57

... More
Ninth Floor

1

1286

1286.71

... More
32mm Dia

-

-

-

... More
Ground Floor

1

1937

1937.74

... More
First Floor

1

1944

1944.89

... More
Second Floor

1

1952

1952.03

... More
third Floor

1

1959

1959.17

... More
Seventh Floor

1

1987

1987.75

... More
Eirth Floor

1

1994

1994.89

... More
Ninth Floor

1

2002

2002.03

... More
Supplying, Fittings & Fixing with all labour, T&P as per specification, the following flexible PVC connection pipes and waste pipe making connection with pillar cock, cistern. Wash hand basin at all height and all floors with all jointing materials etc. complete as per direction of the Engineer -in- charge.

-

-

-

... More
(a) 450-600 mm long 15mm dia PVC connection pipe

110

8818

80.17

... More
(b)32 mm dia flexible PVC waste pipe 1mtr each

55

3961

72.03

... More
Sub Head 3: Internal drainage/ Soil and Waste piping Providing and fixing PVC floor trap self cleansing design with or without vent arm complete including cutting and making good the walls and floors. Make: Supreme, Finolex, Prince etc.., 110mm dia inlet 110mm dia outlet

80

40888

511.1

... More
Providing and laying uPVC pipes of approved make conforming to IS 4985: 2000) working pressure 6 kg/cm2 including all fittings e.g. plain or door bends, junctions, cowls, offsets, Coupler, access pieces etc. jointing with rubber rings and solvent cement including cutting and making good the walls, floors, RCC work, etc., cutting chases and filling the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or cement mortar 1:4 (1 cement : 4 coarse sand)/ Fixing with clamps complete in all respects as per Direction of Engineer-incharge.

-

-

-

... More
40mm dia

96

13651

142.2

... More
50mm dia

48

14443

300.9

... More
Providing and fixing UPVC SWR pipe for soil, waste and vent pipe to IS : 13592 of SWR quality, including all fittings, like EG : Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement by application of leak proof adhesive like FRP paste including cutting holes in walls and floors and making good. clipping to walls and slabs, trenching, refilling etc. complete Make: Supreme, Finolex, Prince 110mm dia

-

-

-

... More
Ground Floor

50

24717

494.34

... More
First Floor

50

25005

500.1

... More
Second Floor

50

25293

505.87

... More
third Floor

50

25581

511.63

... More
Seventh Floor

50

26734

534.68

... More
Eirth Floor

50

27224

544.48

... More
Ninth Floor

50

27713

554.27

... More
110mm dia Soil, Waste Downcomer/Shaft Pipe

450

234666

521.48

... More
75 mm dia Antisyphon Pipe

148

57167

386.27

... More
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4.5 KG & FRAME MIN.2.7 KG )180x150 mm size P type With FPS bricks

6

15204

2534

... More
Providing and fixing SS grating with rim including setting in floor with white cement mortar and making good the floor (Chilli make) 125mm dia (Lowest retail price not less than 120/each.Make: Supreme, Finolex, Cera, crome etc..,

110

30118

273.8

... More
Supplying, fitting & fixing of following size of UPVC,CLASS-B(SWR) fittings of ISI marked to UPVC pipes (on concrete / Brick walls and grounds) with all materials labour T&P including cutting of the walls, with supply of nails, bobbins and wooden plugs as required including scaffolding etc. complete in all respect as per direction of the Engineer in charge.

-

-

-

... More
(a) 110 mm dia Single Junction with door

64

23176

362.13

... More
(b) 110 mm dia Door Bend

16

3745

234.11

... More
(c) 110 mm dia Heel Rest Bend

16

4054

253.43

... More
(d) 110 mm dia 'P' Trap

32

16743

523.23

... More
(e) 110 mm dia Off set

32

10334

322.96

... More
(f)110 mm dia plain bend

16

3167

197.98

... More
(g) 110 mm dia Cowl

16

1742

108.91

... More
110x75 mm dia T junction

16

3414

213.4

... More
75 mm dia Single Junction with door

16

3139

196.2

... More
75 mm dia Single Junction without door

16

2850

178.14

... More
75 mm dia Cowl

8

394

49.28

... More
Sub Head 4: Water Coolar with Water Purifier/ R.O. Plant Providing & fixing commercial water purifier of water flow rate 2.0 - 2.5 Lit/min. Including all components as per manufacture specifications, including connection from water supply line, and final connection to water cooler electric wiring & plug top etc. with all accessories.Note : Water Purifier Make will be approved by engineer in charge and Price should be inclusive of 1 year Comprehensive warranty and Services etc.

-

-

-

... More
Ro Filter with 150 litres per hour Storage Capacity - 150 Itrs (as per make System with International Standard) cooling system. Make: Thermax/Toro/Ion Exchange.High quality systems built to meet flow requirements for Govt of India office. Pressure Sand Filter Pre Filter Stage 1 : minimum 10 Micron PP Filter Pre Filter Stage 2 : minimum 5 Micron PP Filter Carbon Filter Motor: 0.5 Hp 230 ~ AC volt. Membrane: 25 X 40 L Automatic on & off System: Radar switch.Production Rate: 150 Lph. Power Consumption: 230 ~ Volt AC ( 0.5 H.P)

8

538936

67367

... More
Providing and fixing water cooling machine of 150 liter / hour production rate with 150 Lts. storage for drinking water.(Make : VOLTAS, BLUESTAR)

8

734068

91758.5

... More
Sub Head 5: Fitting, Fixing of Floor & Wall Tiles in Toilets Providing and Fixing Floor Tiles inculding rate of material

120

117960

983

... More
Providing and Fixing Wall Tiles inculding rate of material

374.6

380518

1015.8

... More
Fire Fighting Hydrant and water supply system Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. Dia

225

441225

1961

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia.

750

400500

534

... More
32 mm dia.

620

389980

629

... More
40 mm dia.

175

132125

755

... More
50 mm dia.

202

214928

1064

... More
65 mm dia.

285

362235

1271

... More
80 mm dia.

260

392340

1509

... More
100 mm dia.

22

45210

2055

... More
150 mm dia.

80

229200

2865

... More
200 mm dia (wall thickness 6.3 mm)

10

44370

4437

... More
250 mm dia (wall thickness 6.3 mm)

10

55690

5569

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gun Metal

6

38376

6396

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gun Metal

13

82771

6367

... More
Supplying and fixing of MS hose cabinet box made of 2 mm thick MS Sheet and 40 x 40 x 5mm angle iron with front openable cover having 6mm thick glazed glass viewing window i/c necessary locking arrangement on existing wall/ brick platform etc complete as required.

-

-

-

... More
Size 1800 mm x 900 mm x 500 mm

12

243372

20281

... More
Size 900 mm x 600 mm x 500 mm

-

-

-

... More
Providing and fixing angle iron (40mmx40mmx5mm) door frame and MS sheet (6mm thick) cum glass shutter of size 2.1mtrx0.9mtr(N.S.) with 25mmx25mmx3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required. Glass shall be 6 mm thick.

6

32761

5460.32

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun Metal

19

39672

2088

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

2

2184

1092

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

38

172140

4530

... More
Supplying and fixing First-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

13

91260

7020

... More
Supply and Installation of Shock Proof FIREMAN's AXE of approved make as per IS Code.

19

103241

5433.75

... More
Providing, Fixing, Testing and commissioning of 15 mm dia. Quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:

-

-

-

... More
Pendent Sprinklers

530

197160

372

... More
Upright Sprinklers

22

8184

372

... More
Providing and Fixing of pressure switch in M.S. pipe line including connection etc. as required.

11

13992

1272

... More
Providing and Fixing flow switch in following sizes M.S. pipe line including connection etc. as required. 100 mm dia.

11

68761

6251

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
1000 mm

22

28600

1300

... More
1200 mm

22

28600

1300

... More
1500 mm

22

33528

1524

... More
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner.

16

12000

750

... More
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.

45

268970

5977.13

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension braket as required as per specifications.

45

233651

5192.25

... More
MICROPROCESSOR & ALRAM SYSTEM with Electronics System Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Ten Loop Panel.

1

401948

401948.69

... More
Supplying, installation, testing & commissioning of Heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

14

12742

910.15

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

257

643008

2501.98

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

125

26608

212.87

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

12

34397

2866.48

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

23

78181

3399.19

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

23

70748

3076

... More
Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm X 75 mm X 60 mm deep

257

113748

442.6

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. (For smoke detector amd MCP and all type detector)

2735

194075

70.96

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (For response indicator)

420

202246

481.54

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm (For response indicator)

480

771657

1607.62

... More
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.

12

16650

1387.52

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

5

13151

2630.22

... More
Supplying, installation, testing & commissioning of addressable fire monitor module complete as required.

5

13151

2630.22

... More
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

1

95801

95801.97

... More
Supply, installation, testing & commissioning of RS232/RS485 interface communication Module

1

24241

24241.96

... More
Supply, installation, testing & commissioning of Fire Fighter Telephone System

1

78979

78979.56

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

2

10208

5104.13

... More
Fire Pump and Motor in Fire House With Internal Electrification works Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 88 m Head

2

790446

395223

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

1

596558

596558

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 88 m Head

2

218906

109453

... More
CONTROL PANELS Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
Incomings 800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-800 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 1000Amps Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pumps 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 Sets

-

-

-

... More
Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual /OFF operation. - 2 Sets Diesel Engine Control

-

-

-

... More
Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual /OFF operation. - 2 Sets Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter

1

504788

504788

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :

-

-

-

... More
250mm dia.

3

121038

40346

... More
200mm dia.

3

102135

34045

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
150mm dia.

11

80069

7279

... More
100mm dia.

1

5373

5373

... More
80mm dia.

14

56812

4058

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
100 mm dia.

2

18426

9213

... More
150 mm dia.

3

45393

15131

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
150 mm dia.

1

15131

15131

... More
200 mm dia.

2

38098

19049

... More
250 mm dia.

3

70776

23592

... More
Providing and fixing in position the industrial type pressure gauges with gun metal/brass valves complete as required.

6

7632

1272

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia

1

41588

41588

... More
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 25 mm dia

2

872

436

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :4 way-150 mm dia M.S. Pipe

1

11916

11916

... More
Providing, fixing, testing and commissioning of Precharged air vessel (size 450 mm dia & 2000 mm height) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, minimum 50 mm dia inlet with isolating valve Puly painted from inside and outside with two coats of synthetic enamel paint over a coat of primer complete as required. (Vessel should be suitable for rated working pressure).

1

31395

31395

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) portable fire extinguisher, water (gas pressure) type capacity 9 ltr. with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications.

2

1303

651.89

... More
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25-400 sq.mm direct in ground in the existing RCC/HUME/ STONEWARE/METAL pipe as required.

-

-

-

... More
MV cable laying up to 25 sq.mm in ground

44.6

1942

43.56

... More
MV cable laying from 25 sq.mm to 400 sq.mm in existing pipe in ground

94.6

5636

59.58

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.

-

-

-

... More
3½ x 35 sq.mm

4

1353

338.48

... More
3 x 25 sq.mm

4

1339

334.88

... More
3x 10 sq.mm

4

740

185.04

... More
2x 6 sq.mm

4

615

153.79

... More
BASIC RATES FOR MATERIALS PVC INSULATED ALUMINUM CONDUCTOR

-

-

-

... More
35 sq.mm 3 core PVC Armoured Cables ISI Marked

66.4

17011

256.19

... More
25 sq.mm 3 1/2 core PVC Armoured Cables ISI Marked

28.2

5951

211.05

... More
10 Sq.mm 3 core PVC Armoured Cables ISI Marked

32.6

5519

169.31

... More
6 sq.mm 2 core PVC Armoured Cables ISI Marked

12

1119

93.25

... More
Internal Hydrant Syatem typical 1st Floor to 9th Floor Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe.

-

-

-

... More
25 mm dia.

70

37380

534

... More
32 mm dia.

60

37740

629

... More
40 mm dia.

15

11325

755

... More
50 mm dia.

18

19152

1064

... More
65 mm dia.

25

31775

1271

... More
80 mm dia.

20

30180

1509

... More
100 mm dia.

2

4110

2055

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gun Metal

1

6367

6367

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

2

9060

4530

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 .20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

1

7020

7020

... More
Supplying and fixing of MS hose cabinet box of made of 2 mm thick MSsheet and 40 x 40 x 5mm angle iron with front openable cover having 6mm thick glazed glass viewing window i/c necessary locking arrangementon existing wall/ brick platform etc complete as required. Size 1800 mm x 900 mm x 500 mm

1

20281

20281

... More
Supplying and Fixing 63 mm dia. Gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required: Gun Metal

1

2088

2088

... More
providing, Fixing, Testing and commissioning of 15 mm dia. Quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Pendent Sprinklers

50

18600

372

... More
upright Sprinklers

2

744

372

... More
Providing and Fixing of pressure switch in M.S. pipe line including connection etc. as required.

1

1272

1272

... More
Providing and Fixing flow switch in following sizes M.S. pipe line including connection etc. as required. 100 mm dia.

1

6251

6251

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
1000 mm

5

6500

1300

... More
1200 mm

5

6500

1300

... More
1500 mm

5

7620

1524

... More
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner.

1

750

750

... More
For 9Nos of Floor

9

2382435

264715

... More
Supply and Installation of Shock Proof FIREMAN's AXE of approved make as per IS Code.

1

5433

5433.75

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension braket as required as per specifications.

4

20768

5192

... More
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.

4

23988

5997.13

... More
For 9Nos of Floor

9

451710

50190

... More
Internal Hydrant System for Ground Floor Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe.

-

-

-

... More
25 mm dia.

70

37380

534

... More
32 mm dia.

45

28305

629

... More
40 mm dia.

20

15100

755

... More
50 mm dia.

20

21280

1064

... More
65 mm dia.

40

50840

1271

... More
80 mm dia.

25

37725

1509

... More
100 mm dia.

2

4110

2055

... More
150 mm dia.

25

71625

2865

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gun Metal

1

6367

6367

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

2

9060

4530

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585. 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

1

7020

7020

... More
Supplying and fixing of MS hose cabinet box of made of 2 mm thick MSsheet and 40 x 40 x 5mm angle iron with front openable cover having 6mm thick glazed glass viewing window i/c necessary locking arrangementon existing wall/ brick platform etc complete as required. Size 1800 mm x 900 mm x 500 mm

1

20281

20281

... More
Supplying and Fixing 63 mm dia. Gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required: Gun Metal

1

2088

2088

... More
Providing, Fixing, Testing and commissioning of 15 mm dia. Quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Pendent Sprinklers

50

18600

372

... More
upright Sprinklers

2

744

372

... More
Providing and Fixing of pressure switch in M.S. pipe line including connection etc. as required.

1

1272

1272

... More
Providing and Fixing flow switch in following sizes M.S. pipe line including connection etc. as required. 100 mm dia.

1

6251

6251

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
1000 mm

5

6500

1300

... More
1200 mm

5

6500

1300

... More
1500 mm

5

7620

1524

... More
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner.

1

750

750

... More
Supply and Installation of Shock Proof FIREMAN's AXE of approved make as per IS Code.

1

5433

5433.75

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension braket as required as per specifications.

4

20769

5192.25

... More
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.

4

23908

5977.13

... More
Internal Hydrant System for Basement Floor Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : Note: Threaded joint upto 50mm diameter pipe. Welded joint above 50mm diameter pipe.

-

-

-

... More
25 mm dia.

50

26700

534

... More
32 mm dia.

35

22015

629

... More
40 mm dia.

20

15100

755

... More
50 mm dia.

20

21280

1064

... More
65 mm dia.

20

25420

1271

... More
80 mm dia.

15

22635

1509

... More
100 mm dia.

2

4110

2055

... More
150 mm dia.

25

71625

2865

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gun Metal

1

6367

6367

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

2

9060

4530

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

-

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

1

7020

7020

... More
Supplying and fixing of MS hose cabinet box of made of 2 mm thick MSsheet and 40 x 40 x 5mm angle iron with front openable cover having 6mm thick glazed glass viewing window i/c necessary locking arrangementon existing wall/ brick platform etc complete as required. Size 1800 mm x 900 mm x 500 mm

1

20281

20281

... More
Supplying and Fixing 63 mm dia. Gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required: Gun Metal

1

2088

2088

... More
providing, Fixing, Testing and commissioning of 15 mm dia. Quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:

-

-

-

... More
Pendent Sprinklers

30

15660

522

... More
upright Sprinklers

2

1044

522

... More
Providing and Fixing of pressure switch in M.S. pipe line including connection etc. as required.

1

1546

1546

... More
Providing and Fixing flow switch in following sizes M.S. pipe line including connection etc. as required.

-

-

-

... More
100 mm dia.

1

7514

7514

... More
150 mm dia.

-

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
1000 mm

2

3156

1578

... More
1200 mm

2

3340

1670

... More
1500 mm

2

3666

1833

... More
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner.

1

750

750

... More
Supply and Installation of Shock Proof FIREMAN's AXE of approved make as per IS Code.

1

5433

5433.75

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension braket as required as per specifications.

4

20769

5192.25

... More
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.

4

23910

5977.73



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.