Odisha State Disaster Management Authority Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha State Disaster Management Authority - OSDMA Tender

Opening Date21 Sep 2018
Closing Date29 Oct 2018
Tender Amount₹ 58,69,80,484 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Construction Of State Institute Of Disaster Management At Gothapatna, Bhubaneswar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Upto 1.5 Mtr Depth

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

223

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

256.5

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

254.1

-

-

... More
Training Tower

74.9

-

-

... More
Climbing Wall

34.4

-

-

... More
Rubble Field

661.4

-

-

... More
Landscape Works

-

-

-

... More
Fencing

22.1

-

-

... More
Retaining Wall

72

-

-

... More
Pathways, Amphitheater & other Structures

3655.1

-

-

... More
Gazebos & Pergolas

11.3

-

-

... More
Playcourts

172.5

-

-

... More
Parking Shed

5.6

-

-

... More
Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered complete as per specification and Direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

669

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

769.5

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

762.3

-

-

... More
Training Tower

224.6

-

-

... More
Climbing Wall

103.1

-

-

... More
Rubble Field

1984.3

-

-

... More
Landscape Works

-

-

-

... More
Fencing

66.2

-

-

... More
Retaining Wall

216

-

-

... More
Pathways, Amphitheater & other Structures

20.5

-

-

... More
Gazebos & Pergolas

33.8

-

-

... More
Playcourts

517.5

-

-

... More
Parking Shed

16.9

-

-

... More
Filling the Foundation and Plinth, sides of foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance,loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

297

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

341.6

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

338.5

-

-

... More
Training Tower

99.8

-

-

... More
Climbing Wall

45.8

-

-

... More
Rubble Field

132.3

-

-

... More
Landscape Works

-

-

-

... More
Fencing

29.4

-

-

... More
Retaining Wall

96

-

-

... More
Pathways, Amphitheater & other Structures

182.8

-

-

... More
Gazebos & Pergolas

15

-

-

... More
Play Court

34.5

-

-

... More
Parking Shed

7.5

-

-

... More
Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance,royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

622.2

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

694.5

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

628.3

-

-

... More
Training Tower

47.6

-

-

... More
CONCRETE WORK

-

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:4:8) using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

255.1

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

248.7

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

560

-

-

... More
Training Tower

22.5

-

-

... More
Climbing Wall

8.3

-

-

... More
Rubble Field

143.2

-

-

... More
Landscape Works

-

-

-

... More
Fencing

12.7

-

-

... More
Retaining Wall

48

-

-

... More
Pathways, Amphitheater & other Structures

1217.9

-

-

... More
Gazebos & Pergolas

16.9

-

-

... More
Playcourts

69

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:2.5:5) using 20 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

9.3

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

9.5

-

-

... More
REINFORCED CEMENT CONCRETE

-

-

-

... More
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running Charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-Charge but excluding the cost of steel reinforcement

-

-

-

... More
R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

572.5

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

560.7

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

812.8

-

-

... More
Training Tower

79.8

-

-

... More
Climbing Wall

49.7

-

-

... More
Rubble Field

336

-

-

... More
Landscape Works

-

-

-

... More
Fencing

101.3

-

-

... More
Retaining Wall

180

-

-

... More
Pathways, Amphitheater & other Structures

19.8

-

-

... More
Gazebos & Pergolas

10.6

-

-

... More
Playcourts

69

-

-

... More
R.C.C. Grade beams

-

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

231

-

-

... More
Training Tower

155.5

-

-

... More
Climbing Wall

15

-

-

... More
Rubble Field

1872.7

-

-

... More
Landscape Works

-

-

-

... More
Gazebos & Pergolas

29.4

-

-

... More
R.C.C. Beams, columns, grider and bressmer etc.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

228.1

-

-

... More
First Floor

228.1

-

-

... More
Second Floor

228.1

-

-

... More
Third Floor

30.6

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

387.9

-

-

... More
First Floor

317.7

-

-

... More
Second Floor

296.5

-

-

... More
R.C.C. Floor and Roof slab, landing, balconies up to 4.3Mtr. Height.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

302

-

-

... More
First Floor

302

-

-

... More
Second Floor

210.5

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

284.1

-

-

... More
First Floor

220.4

-

-

... More
Second Floor

191.2

-

-

... More
R.C.C. Lintels.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

1.1

-

-

... More
First Floor

1.1

-

-

... More
Second Floor

1.1

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

10.4

-

-

... More
First Floor

10.4

-

-

... More
Second Floor

10.4

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

5

-

-

... More
Training Tower

3.1

-

-

... More
R.C.C. walls & fins

-

-

-

... More
Training Facilities

-

-

-

... More
Climbing Wall

103.5

-

-

... More
Landscape Works

-

-

-

... More
Retaining Wall

360

-

-

... More
Parking Shed

6.5

-

-

... More
Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.)

-

-

-

... More
Institute Building

-

-

-

... More
Upto Plinth

858.8

-

-

... More
Ground Floor

796.8

-

-

... More
First Floor

825

-

-

... More
Second Floor

659.6

-

-

... More
Terrace Floor

45.9

-

-

... More
Hostel Block

-

-

-

... More
Upto Plinth

841.1

-

-

... More
Ground Floor

1023.6

-

-

... More
First Floor

822.8

-

-

... More
Second Floor

733.2

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

1573.2

-

-

... More
Training Tower

353

-

-

... More
Climbing Wall

252.3

-

-

... More
Rubble Field

2208.7

-

-

... More
Landscape Works

-

-

-

... More
Fencing

14.1

-

-

... More
Retaining Wall

270

-

-

... More
Pathways, Amphitheater & other Structures

19.8

-

-

... More
Gazebos & Pergolas

60

-

-

... More
Playcourts

69

-

-

... More
Parking Shed

9.8

-

-

... More
BRICKWORK

-

-

-

... More
Providing and laying Brick masonry work in Foundation & Plinth using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

39.7

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

39.9

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

115.9

-

-

... More
Landscape Works

-

-

-

... More
Pathways, Amphitheater & other Structures

437.7

-

-

... More
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

220.3

-

-

... More
First Floor

209.3

-

-

... More
Second Floor

185.5

-

-

... More
Terrace

37.1

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

498.7

-

-

... More
First Floor

453.9

-

-

... More
Second Floor

438.7

-

-

... More
Third Floor

131.2

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

470.1

-

-

... More
Training Tower

55.2

-

-

... More
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at Nos. 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

9.5

-

-

... More
First Floor

7.8

-

-

... More
Second Floor

5.7

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

9.6

-

-

... More
First Floor

9.6

-

-

... More
Second Floor

4.9

-

-

... More
WATER PROOFING WORK

-

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
Cleaning the Surface and removing dusts and dirts to ensure that existing Substrate surface is clean, dry, smooth and free of contaminants such as grease, coal tar and oil based products removed without traces and sharp edges, fins and rough surfaces that could damage the membrane are removed.

-

-

-

... More
Providing and Appling at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with specified manufacture's compound at dosage of 1.0 L per 50kg cement where ever necessary

-

-

-

... More
Providing & Applying 3 Coats of single component acrylic polymer modified reinforced high build water proofing compound after priming on the roofs, to get a minimum dry thickness of 1mm as per manufacturer’s specification. The cured membrane should exhibit the tensile strength of 1.1 Mpa as per ASTM D412 with elongation 100% as ASTM D12,with very low penetration to rapid chloride as per ASTM C 1202-03,with pull off Adhesion 0.92 MPa as per ASTM D4541.The cured membrane should also have resistance to Algae growth as per ASTM D 5589-97 with permeability of 5mm as per BSEN 12390 part 8,with water vapour transmission 6 g/m²h as per BSEN 12390 part 8. including the cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1921.5

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

2144.6

-

-

... More
Training Facilities

-

-

-

... More
Training Tower

144

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:4 (1 cement : 4 fine sand) as per standard design including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

223.3

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

250.8

-

-

... More
Training Facilities

-

-

-

... More
Training Tower

48.8

-

-

... More
STEEL WORK

-

-

-

... More
Hoisting joists and trusses and placing in position including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

3226.4

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

196000

-

-

... More
Landscape Works

-

-

-

... More
Parking Shed

41250

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
80x1.25 mm M.S. laths with 1.25 mm thick top cover

-

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

4200

-

-

... More
Supplying, fitting & fixing of M.S. grill made out of M.S. flats/square bars as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in Charge.

-

-

-

... More
Landscape Works

-

-

-

... More
Gazebos & Pergolas

7423.72

-

-

... More
ROOFING WORK

-

-

-

... More
Providing & Painting two or more coats with heat Reflective (S.R.I) paint of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Third Floor

1921.5

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

2144.6

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per Sqm. as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in Charge.

-

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

7056

-

-

... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m² including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in Charge.

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

81.4

-

-

... More
Landscape Works

-

-

-

... More
Gazebos & Pergolas

289.5

-

-

... More
EXTERNAL FINISHING WORK

-

-

-

... More
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

2197.9

-

-

... More
First Floor

1787.2

-

-

... More
Second Floor

1612.3

-

-

... More
Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

1318.9

-

-

... More
First Floor

1227.5

-

-

... More
Second Floor

1062.6

-

-

... More
Third Floor

188.7

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

3127.5

-

-

... More
First Floor

2864.5

-

-

... More
Second Floor

2677.2

-

-

... More
Third Floor

770.1

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

4774

-

-

... More
Training Tower

432

-

-

... More
Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

1369.7

-

-

... More
First Floor

1301.3

-

-

... More
Second Floor

1153.3

-

-

... More
Third Floor

230.7

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

3577.6

-

-

... More
First Floor

3256.2

-

-

... More
Second Floor

3147.2

-

-

... More
Third Floor

941.2

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

5782

-

-

... More
Landscape Works

-

-

-

... More
Retaining Wall

360

-

-

... More
BUILDING ENVELOPE FINISHING

-

-

-

... More
CLADDINGS

-

-

-

... More
Stone work (machine cut edges) for wall lining etc. (stone veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :White sand stone - Exposed face machine cut and table rubbed with rough backing 30 mm thick including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.(To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately)

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

696

-

-

... More
First Floor

508.8

-

-

... More
Second Floor

764

-

-

... More
Third Floor

330

-

-

... More
Stone work (machine cut edges) for wall lining etc. (stone veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Red sand stone - Exposed face machine cut and table rubbed with rough backing 30 mm thick including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge. (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

240

-

-

... More
First Floor

240

-

-

... More
Second Floor

120

-

-

... More
Third Floor

30

-

-

... More
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required including cost of all materials, conveyance, loading and unloading,cost of labour, scaffolding, staging, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

324

-

-

... More
First Floor

324

-

-

... More
Second Floor

162

-

-

... More
Third Floor

40.5

-

-

... More
Hostel Block

-

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including

-

-

-

... More
Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design

-

-

-

... More
Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (Nos. 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.

-

-

-

... More
The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in Sqm.. up to two decimal places

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

180

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

129.5

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality including cost of all materials, conveyance, loading and unloading,cost of labour, scaffolding, staging, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Minimum 1.5 mm thick as per Manufacturer's specifications

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

900

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

60

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including cost of all materials, conveyance, loading and unloading,cost of labour, scaffolding, staging, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1862.5

-

-

... More
Hostel Building

-

-

-

... More
Building Proper

521.7

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm..“

-

-

-

... More
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement including cost of all materials, conveyance, loading and unloading,cost of labour, scaffolding, staging, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1862.5

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

521.7

-

-

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

186.3

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

26.1

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi metallic contacts, all complete to perform as per specification and approved drawings.

-

-

-

... More
The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.

-

-

-

... More
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental Charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured all complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

106.6

-

-

... More
Supplying fitting, fixing fully glazed aluminum framed openable windows using 15 micron anodized OEL aluminum section 2082 as out section, 9139 as mullion section, 4124 as a shutter section frame with tapered clip of section 4125, aluminum angle , rubber beading, friction stay and handle etc. with 5mm black glass as panel fitted with rubber beading including locking arrangement ,all fittings and the cost of all materials, cost of labour, conveyance, loading, unloading, hire and running Charges of drilling machine, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

3210.4

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

594.3

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

1008

-

-

... More
Providing and fixing 12mm thick prelaminated particle board, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P.brass / stainless steel screws etc.l including the cost of all materials, necessary locking arrangements, fittings, cost of labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

268.8

-

-

... More
Providing and fixing 6 mm thick Plain glass in aluminium door, window, ventilator shutters and partitions etc. with Plain glass of appropiate thickness, EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

256.8

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

505.2

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

100.8

-

-

... More
Providing and fixing following Aluminium accessories. including the cost of all materials , T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Aluminium Sliding Door bolts - 300 x 16 mm

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

138

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

363

-

-

... More
Aluminium Sliding Door bolts - 250 x 16 mm

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

123

-

-

... More
Aluminium Tower bolts - 250 x 10 mm

-

-

-

... More
Institute Building

176

-

-

... More
Building Proper

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

369

-

-

... More
Aluminium Tower bolts - 150 x 10 mm

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

356

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

943

-

-

... More
Aluminium Pull bolt lock

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

120

-

-

... More
Aluminium handles - 125 mm Door Handles

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

352

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

738

-

-

... More
Aluminium handles - 100 mm window Handles

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

314

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

406

-

-

... More
Aluminium Door Stopper - Twin rubber

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

176

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

369

-

-

... More
Brass hasps and staples (safety type) - 150 mm

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

232

-

-

... More
Aluminium U beading

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

2911.5

-

-

... More
Aluminium casement window fastener

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

90

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

406

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

168

-

-

... More
Vision panel

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

208

-

-

... More
Providing & Painting two or more coats with Premium quality Acrylic Smooth (Exterior grade) Paint with Silicon Additives of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-Charge. (Note: Colour & Shade to be approved before procurment & use)

-

-

-

... More
Hostel Block

-

-

-

... More
Third Floor

478.8

-

-

... More
Providing and Painting with mixed pink or Grey primer of approved make & to make an even finished surface in all heights with all scaffolding and staging Charges including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

867.6

-

-

... More
Providing & Painting two or more coats with texture exterior paint of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

504

-

-

... More
First Floor

403.2

-

-

... More
Second Floor

476

-

-

... More
Third Floor

119

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

3577.6

-

-

... More
First Floor

3256.2

-

-

... More
Second Floor

3147.2

-

-

... More
Third Floor

941.2

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

5782

-

-

... More
Training Tower

3522.2

-

-

... More
Landscape Works

-

-

-

... More
Retaining Wall

600

-

-

... More
MISC. CIVIL WORKS FOR SERVICES

-

-

-

... More
Providing and fixing 12 mm thick Toughened glass railing of 1m ht. with 50mm dia SS Rail mounted inside for safety and vertical SS supports upto 25mm x 50mm tubes with min 2mm thickness fixed to the floor using adequate number of fasteners as per the approved shop drawing . including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

75

-

-

... More
Providing and leaving PVC sleeves during formwork in RCC wall, slabs, beam, parapets, and other locations as called for, sleeves cut to required sizes, complete as per detailed drawings at all levels.(Length - upto 400mm) including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
75 mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

50

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

10

-

-

... More
100 mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

50

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

10

-

-

... More
150 mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

150

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

2

-

-

... More
200 mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

150

-

-

... More
Core cutting in RCC slab / wall and other locations, including finishing the same with anti shrinkage grouting, water proofing, applying sealent if required etc. complete.as required including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
75mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

10

-

-

... More
100mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

10

-

-

... More
150mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

10

-

-

... More
200mm dia

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

10

-

-

... More
Providing and fixing sheet covering over expansion joints Aluminium fluted strips 3.15 mm thick.with iron screws as per design including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
150 mm wide

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

222

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

234

-

-

... More
SITE LEVEL MISC WORKS

-

-

-

... More
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness including cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

68782

-

-

... More
PROTECTING EXISTING TREES AT SITE

-

-

-

... More
Constructing Half brick circular tree guard in Fly-ash bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

50

-

-

... More
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

75

-

-

... More
Excavating 200 mm of Over burden deposited soil including Top Soil in hard soil from the site and storing the same for reuse at a designated location with in the site. with cost of labour, labour cess, hire & running Charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in Charge.

4126.9

-

-

... More
Grassing with Doob grass over the mound including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

1031.7

-

-

... More
Constructing R.C.C. Standards post/ struts/rails/ poles of mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required including cost, conveyance,of all materials, cost of all labours, T & P, sundries etc. as required for the work complete as per the direction of the Engineer-in-Charge.

13.5

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:2:4) using 20 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
Institute Building

64.8

-

-

... More
Hostel Block

52.9

-

-

... More
Providing Brick edging 7cm wide 11.4 cm deep for plinth protection with Fly ash Bricks including grouting with cement mortar 1:4 (1 cement : 4 fine sand) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
Institute Building

288

-

-

... More
Hostel Block

234.9

-

-

... More
ROAD WORKS

-

-

-

... More
Construction of granular sub-base by providing Close graded Granular subbase using Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

2136.8

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

2136.8

-

-

... More
Cleaning the existing granular base surface including removal of binding materials and other foreign materials with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and/or compressed air to receive bituminous Surface.

14245.2

-

-

... More
Providing and laying bituminous macadam using grading II materials with hot mix plant using crushed aggregates of specified grading premixed with bituminous binder of 60/70 penetration grade of bitumen, transported to site, laid over a previously prepared surface with a hydrostatic paver finisher with sensor control to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per Clause 504 of MoSRT&H Specifications for Road & Bridge works (4th Revision) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

712.3

-

-

... More
Providing and laying semi dense bituminous concrete using grading II materials with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder of 60/70 penetration grade of bitumen, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheelede, vibratory and tandem rollers to achieve the desired compaction as per Clause 508 of MoSRT&H Specifications for Road & Bridge works (4th Revision) including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

356.1

-

-

... More
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/Sqm. using mechanical means including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

14245.2

-

-

... More
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per Sqm. on the prepared bituminous/granular surface cleaned with mechanical broom including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

14245.2

-

-

... More
Road Marking by Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per Sqm. area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

300

-

-

... More
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing

-

-

-

... More
80 x 60 Cm rectangular

15

-

-

... More
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, finishing the top smooth etc. including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of all machineries, etc. all complete as per the direction of the Engineer -in -Charge

2667.4

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:2.5:5) using 12 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties,cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
In Kerbs,steps etc

83.9

-

-

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. icluding cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

3375.2

-

-

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

3705.4

-

-

... More
EXTERNAL FLOORING

-

-

-

... More
Providing and laying 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Red sandstone

-

-

-

... More
Landscape Works

-

-

-

... More
Pathways, Amphitheater & other Structures

1400

-

-

... More
White sand stone

-

-

-

... More
Landscape Works

-

-

-

... More
Pathways, Amphitheater & other Structures

525

-

-

... More
Providing and laying 80mm thick factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
80mm thick cement concrete paver block of M-30 grade with approved colour, design & pattern.

-

-

-

... More
Landscape Works

-

-

-

... More
Parking Shed

1255.5

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.

2668

-

-

... More
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick sand, including spreading, well ramming, consolidating and finishing smooth etc. including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.

1495.8

-

-

... More
Coloured concrete: 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.

9543.4

-

-

... More
Providing & laying granite stone tiles in Coping/cladding using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm. to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.)

100

-

-

... More
INTERIOR WORKS

-

-

-

... More
FALSE CEILING WORKS

-

-

-

... More
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of 350 kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorption 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1921.5

-

-

... More
Providing and fixing GI Metal tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ Sqm., both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm.

-

-

-

... More
Laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-Charge.

-

-

-

... More
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/Sqm. (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece complete in all respect as per the directions of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

549

-

-

... More
Providing and fixing Moisture Resistant Gypsum false ceiling at all height using 12.5 mm thick tapered edge gypsum moisture resistant board including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/Sqm. (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre,

-

-

-

... More
to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Nos. having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

2964

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

119.3

-

-

... More
Providing and fixing Calcium Silicate false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per Sqm. including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per Sqm.) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm.

-

-

-

... More
Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

186.3

-

-

... More
Providing and fixing 15 mm thick Armstrong / Equivalent false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

912.5

-

-

... More
Providing & fixing false ceiling at all heights with With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles of size 595 x 595 of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per Sqm. including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per Sqm.) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall SS screws. The work shall be carried out as per specifications, drawing and as per directions of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

365

-

-

... More
Ribbed Ceiling - Providing & fixing of "Nittobo" Double layered false ceiling system comprising of secondary layer of 12mm thick linear Nitobo Solation Accoustical Mineral Fiber Tiles in size 600X600mm having density of 350 kg/m3 and NRC value of 0.50 in approved design stuck and stapled on primary layer of 9.5mm thick Gypsum Board. The Gypsum Board is fixed on the frame comprising of GI perimeter channels of size 0.55mm thick having one flange, one flange of 30mm and a web of 27mm along with perimeter screw fixed to wall with nylon sleeves and screws, then suspending GI intermediate channels of size 45mm, 0.9mm thick with two flanges of 15mm Nos. fixed to soffit @1220mm c/c with ceiling angle of 25mmX10mmX0.55mm fixed to bottom of MS angle members, ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm Nos. with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and indirection perpendicular to the intermediate channel at 457mm c/c, Gypboard is then screw fixed to 230mm centre complete in all respects and as per drawings.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

300

-

-

... More
DOORS & WINDOWS INTERNAL

-

-

-

... More
Providing fitting and fixing in proper position Seasoned Dressed Sal wood Chaukaths 63mm x 125mm size of best quality in doors of approved design and drawing applying coal tar 2 coats with mixing of antitermite on the wall side surface of the choukath including cutting the grooves in chaukaths as required, with masonry or concrete surface fixing including cost of all materials, labour, conveyance, taxes, T&P etc. complete as per direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

5

-

-

... More
Providing fitting & fixing of 35 mm factory made flush door Shutter with both sides finished with veener conforming to IS 2202 including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc, complete but excluding the cost of fitiings as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

356

-

-

... More
Providing, fitting and fixing of Factory made FRP (alternately called GRP) Door frames of size 75mm x 100mm, fabricated using E-glass chopped strand mat (CSM), U.V. stabilized isopthalic Gelcoat and impregnated with isopthalic resin. The thickness of the GRP skin shall not be less than 2.0 mm. The door frame consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frames shall be provided with wooden reinforcement on six loacations for high screw holding capacity for fixing mettalic hold fast and shall be consolidated by filling with medium density foam/ plaster of paris with fibre reinforcement. Six numbers of 260mm x 25mm x 5mm size 'S' shaped MS flat hold fast shall be provided with frame. The material and process for manufacturing the door frames shall confirm to RV-TIFAC composites Design Centre's standards and specifications. The rate include cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

1270.1

-

-

... More
Providing, fitting and fixing of 32mm thick Factory made Single Leaf Rigid FRP (alternately called GRP) Sandwitch composite door shutter laminated with two GRP skins with wood grain finish, fabricated using UV-stabilized isopthalic Gelcoat and one layer of 450 gsm E-glass chopped strand mat (CSM) impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polysterene Structural (EPS) foam panel of 29mm thickness and a density of 20 Kg/Cum shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinforcements for fixing the metal fittings such as tower bolt, aldrop, handles, etc. shall be provided. A structural adhessive compatible with EPS foam shall be used for bending the core materials, the shall wood reinforcements and the skins. The mater. The material and process for manufacturing the door shutter shall confirm to RV-TIFAC composites Design Centre's standards and specifications. The rate include cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

524

-

-

... More
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/Sqm.) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

43.9

-

-

... More
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make,including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-Charge (panneling to be paid for separately).

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

43.2

-

-

... More
Providing and fixing glazing with clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

8.6

-

-

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- Charge, all complete.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

9

-

-

... More
FLOORING WORKS

-

-

-

... More
Providing and laying Kota Stone Flooring confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.)

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

87.5

-

-

... More
First Floor

87.5

-

-

... More
Second Floor

75

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

121.2

-

-

... More
First Floor

66.3

-

-

... More
Second Floor

66.3

-

-

... More
Landscape Works

-

-

-

... More
Pathways, Amphitheater & other Structures

750

-

-

... More
Providing and laying Kota Stone in Dado/Skirting confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

33.3

-

-

... More
First Floor

33.3

-

-

... More
Second Floor

28.5

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

12.1

-

-

... More
First Floor

6.6

-

-

... More
Second Floor

6.6

-

-

... More
Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size between 0.4 Sqm.. to 1.0 Sqm.. & above in floors and landing, etc over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials,royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

959.6

-

-

... More
First Floor

575.8

-

-

... More
Second Floor

383.8

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

110

-

-

... More
First Floor

66

-

-

... More
Second Floor

44

-

-

... More
Landscape Works

-

-

-

... More
Pathways, Amphitheater & other Structures

180

-

-

... More
Providing and laying granite stone in Dado/Skirting for wall lining confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

47.8

-

-

... More
First Floor

10.5

-

-

... More
Second Floor

10.5

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

4.9

-

-

... More
First Floor

3

-

-

... More
Second Floor

2

-

-

... More
Providing and laying 600 mm x 600 mm Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

997.6

-

-

... More
First Floor

1330.1

-

-

... More
Second Floor

997.6

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

876.9

-

-

... More
First Floor

876.9

-

-

... More
Second Floor

729.2

-

-

... More
Providing and laying Vitrified Floor Tiles in Dado/Skirting confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

99.8

-

-

... More
First Floor

133

-

-

... More
Second Floor

99.8

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

87.7

-

-

... More
First Floor

87.7

-

-

... More
Second Floor

72.9

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

5350.5

-

-

... More
Providing and laying 40 mm thick rubbed stone flooring using Red Sand Stone of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

234.9

-

-

... More
Providing 18 mm thick Cement plaster in two layers of 12mm and 6mm skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

84

-

-

... More
INTERNAL FINISHING WORKS

-

-

-

... More
Supplying, fitting and fixing of stainless steel of 304 grade in hand rail using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mt c/c and stainless square pipe bacing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

3168

-

-

... More
Hostel Block

-

-

-

... More
Building Proper

3168

-

-

... More
Providing and applying 2 coats of Plastic Emulsion Paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats,including of all materials, labour, conveyance, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-Charge. (colour & shade to be approved before procurment & use)

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

3280

-

-

... More
First Floor

3280

-

-

... More
Second Floor

1640

-

-

... More
Third Floor

410

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

5364.1

-

-

... More
First Floor

4896.6

-

-

... More
Second Floor

5035.5

-

-

... More
Third Floor

1505.9

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

4774

-

-

... More
Training Tower

3456

-

-

... More
Providing and Painting with cement based putty of approved make & to make an even finished surface in all heights with all scaffolding and staging Charges including cost, conveyance of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

1369.7

-

-

... More
First Floor

1301.3

-

-

... More
Second Floor

1153.3

-

-

... More
Third Floor

230.7

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

3577.6

-

-

... More
First Floor

3256.2

-

-

... More
Second Floor

3147.2

-

-

... More
Third Floor

941.2

-

-

... More
Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Note- colour and shade shall be approved before procurement and use.)

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

300

-

-

... More
First Floor

300

-

-

... More
Second Floor

150

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

35.6

-

-

... More
First Floor

35.6

-

-

... More
Second Floor

17.8

-

-

... More
Training Facilities

-

-

-

... More
Workshops & Service Stations

350

-

-

... More
Landscape Works

-

-

-

... More
Gazebos & Pergolas

300

-

-

... More
Parking Shed

50

-

-

... More
PARTITIONS & PANELLING WORKS

-

-

-

... More
Providing & fixing partitions upto ceiling height consisting of Aluminium frame of tube size 50X50mm sq. tube of wall thickness 2mm and required boards including providing & fixing of frames fixed to floor and ceiling at a spacing of 610mm center to centerwith dashfastners of 12.5mm diameter 50mm length or suitable anchor fastener or metal screens with nylon plugs and the studs 48mm wide having one flange of 34mm and other flange 36mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling tubes and placed at a spacing of 610mm center to center by 6mm dia bolts and nuts including fixing of studs along both sides of partitions fixed flush to wall with suitable anchor fastner or metal screws with nylon plugs at spacing of 450mm center to center & fixing of boards to both sides of frame work by 25 mm long dry wall screws on studs, floor & ceiling tubes at the spacing of 300mm center to center. The boards are to be fixed to frame the frame work with joints staggered to avoid through cracks including jointing & finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25mmX25mmX0.2mm) joint finisher & two coats of primer suitable for board as per manufacturer's specifications and directions of Engineer in Charge all complete

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1749.5

-

-

... More
Providing and fixing 12.5mm thick Single Gypsum board fixed with Alumnium frame @ 300mm c/c, including square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with butt joint, jointing compounds, paper tape for plaster board, flush finish with gypsum putty following the practices recommended by the manufacturer India Gypsum, making opening for electrical fittings and fixtures wherever required complete as per manufacturer specifications, drawings and as directed, conducting material testing with records time to time as per specifications complete al as per specification including staging, scaffolding, lead and lift directions of Engineer in Charge all complete.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1750

-

-

... More
Providing and fixing Fabric panel over 12mm thick sitatex soft board coated with fire resistance spray including the cost of all materials, labours all complete as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

350

-

-

... More
Providing and fixing 8mm thick Medium Density Fibre Board conforming to IS IS:14587:1998 with 4 mm thick Laquered Glass of approved make including the cost of the frame,all hardwares,adhesive,labour complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

175

-

-

... More
Providing and fixing 1 mm thk Laminate over 12mm thk commercial ply conforming to IS 303 (1989) of approved make on wood frame work finished with with 6mm X 12mm or 12mm X 12mm groove finished with Aluminium U-channel / or all edges of groove finished with laminate,including the cost of the frame,all hardwares,adhesive,labour complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1050

-

-

... More
Providing and fixing 4mm thick wooden veneer of approved quality and shade over 8 mm medium density fibre board exterior grade (Grade-I) IS:14587:1998 over partitions,including the cost of the frame,all hardwares,adhesive,,making grooves, making necessary cutouts for switch boxes,labour etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

175

-

-

... More
Providing and fixing wall paper (vinyl wall covering) on POP / gypsum board surfaces with suitable adhesive as per manufacturers specifications ,including the cost of all the hardwares,labour complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

175

-

-

... More
Providing and fixing 1mm thick laminate of approved quality and shade over 8mm MDF boards over partitions / POP, including necessary hardwares, glues, making grooves, making necessary cutouts for switch boxes, etc complete as per detailed drawings complete in all respect as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

350

-

-

... More
Providing and fixing 12mm thick frameless Toughened Glass partition including doors in the slot provided using adequate anchorage in the floor below by placing a SS U Channel ( minimum size - 40mm x 30mm ) levelelled in the ground for placing the Glass as per approved shop drawing complete in all respect as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

607.2

-

-

... More
Providing and fixing of composite thickness of 50mm thk with glass wool of 32kg/m3 including all necessary fixing material of approved make wherever required complete as per manufacturer specifications, drawings and as directed, conducting material testing with records time to time as per specifications complete al as per specification including staging, scaffolding, complete in all respect as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

1749.5

-

-

... More
MISC. INTERIORS WORKS

-

-

-

... More
Providing and laying AC-5 grade laminated wooden flooring of approved make over required surfaces with appropiate adhesive as per manufacturer specifications including the cost of all the hardwares,adhesive,labour etc. complete in all respect as per detail drawings and the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

185

-

-

... More
Providing and laying plumb to the ground Artificial Carpet grass by means of nails,adhesives over level surface free from any warpage including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, etc. complete as per the detail drawings and direction of the Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

500

-

-

... More
Blinds

-

-

-

... More
Providing and fixing Vertical blinds with high quality Al top section of approved make as per manufacturer specifications including the cost of all the hardwares,adhesive,labour etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

10

-

-

... More
Providing and fixing Roller blinds with high quality Al top section of approved make as per manufacturer specifications including the cost of all the hardwares,adhesive,labour etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

454

-

-

... More
Providing & pasting Frosted film as per design and manufacturer specifications including the cost of all the hardwares,adhesive etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

152.5

-

-

... More
Internal Signages

-

-

-

... More
Providing and fixing Main Reception back drop internal signage made in 25 mm thk MDF board and finished in laquered glass fixed with S.S. spacers and provision of backlighting for the same including the cost of all the hardwares,adhesive,labour etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

20

-

-

... More
Providing and fixing Main Reception Internal signage made in 8 mm thk. Solid acrylic sections fixed with S.S. spacers and provision of backlighting for the same including the cost of all the hardwares,adhesive,labour etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

10

-

-

... More
Providing and fixing Fire exits, emergency route flourescent sign boards, etc. (readymade) complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

20

-

-

... More
Providing and fixing Signages up to 8"x 1'-0" made of 3-4 mm thick Acrylic sheet of approved shade & quality fixed with 4 No. SS screws including all backing and supports etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

100

-

-

... More
Providing and fixing Signages up to 8"x1'-0" made of 1.5-2 mm thick SS sheet of approved shade & quality fixed with SS screws including all backing and supports etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

200

-

-

... More
Providing and fixing Vinyl cut in shape & any size as specified by the architect/EIC including the cost of all the hardwares,adhesive,labour etc. complete in all respect as per the direction of Engineer-in-Charge

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

40

-

-

... More
Providing and fixing External SS signages, with lighting provisions, permanently fitted to the Building Structure as sizes provided in the 3D views / Detailed drawings including the cost of all the hardwares, adhesive,labour etc. complete in all respect as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Building Proper

30

-

-

... More
INTERNAL ELECTRICAL WORKS

-

-

-

... More
INTERNAL WIRING

-

-

-

... More
Wiring for light point / fan point /exhaust fan point/ call bell point with 1.5 Sqm.m FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch,modular plate ,suitable GI Box and earthing the point with 1.5 Sqm.m FR PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

-

-

-

... More
Institute Building

800

-

-

... More
Hostel Building

1175

-

-

... More
Wiring for twin control light point with 1.5 Sqm.m FR PVC insulated copper condutor single core cable in surface / recessed PVC conduit 2 way modular switch,modular plate,suitable GI box and earthing the point with 1.5 Sqm.m .FR PVC insulated copper conductor single core cable etc as required.

-

-

-

... More
Institute Building

6

-

-

... More
Hostel Building

120

-

-

... More
Wiring for light /power plug with 2x4 Sqm.m FR PVC insulated copper conductor single core cable in surface /recessed PVC conduit along with 1 No 4 Sqm.m FR PVC insulated copper conductor single core cable for loop earthing as required.

-

-

-

... More
Institute Building

6250

-

-

... More
Hostel Building

8950

-

-

... More
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required.

-

-

-

... More
2x1.5 Sqm.m + 1x1.5 Sqm.m earth wire

-

-

-

... More
Institute Building

400

-

-

... More
Hostel Building

350

-

-

... More
2x2.5 Sqm.m + 1 x 2.5 Sqm.m earth wire

-

-

-

... More
Institute Building

6000

-

-

... More
Hostel Building

6250

-

-

... More
2 x 4 Sqm.m + 1 x 4 Sqm.m earth wire

-

-

-

... More
Institute Building

500

-

-

... More
Hostel Building

250

-

-

... More
2x6 Sqm.m + 1x6 Sqm.m earth wire

-

-

-

... More
Institute Building

350

-

-

... More
Hostel Building

250

-

-

... More
4x6 Sqm.m + 2x6 Sqm.m earth wire.

-

-

-

... More
Institute Building

680

-

-

... More
Hostel Building

200

-

-

... More
4x10 Sqm.m + 2x6 Sqm.m earth wire.

-

-

-

... More
Institute Building

300

-

-

... More
Hostel Building

200

-

-

... More
4x16 Sqm.m + 2x6 Sqm.m earth wire.

-

-

-

... More
Institute Building

450

-

-

... More
Hostel Building

350

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch ,connection etc as required.

-

-

-

... More
Institute Building

165

-

-

... More
Hostel Building

830

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 and 5/6 amps modular socket outlet with shulter and 15/16 amps modular switch connection, etc as required.

-

-

-

... More
Institute Building

265

-

-

... More
Hostel Building

160

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

-

-

-

... More
Institute Building

5000

-

-

... More
Hostel Building

1500

-

-

-

-

-

... More
Institute Building

1000

-

-

... More
Hostel Building

750

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing of 25A modular socket outlet and 25A modular SP MCB "C" curve including connections painting etc. as required.

-

-

-

... More
Institute Building

5

-

-

... More
Hostel Building

120

-

-

... More
Supplying and fixing powder coated MS raceways recessed in floors fabricated from 2mm thick MS sheets provided with neoprene gasketted removable cover fabricated from 2mm thick MS sheets (excepting at passage crossing were the thickness shall be 3mm) on the raceway by countersunk cadmium plated screws at intervals of max.300mm including the cost of powder coating as per colour to be approved and including the cost of providing earth links at raceway joints to ensure earth continuity complete as per specification as required and as below.

-

-

-

... More
300mm wide x 40mm deep

-

-

-

... More
Institute Building

350

-

-

... More
Hostel Building

-

-

-

... More
200mm wide x 40mm deep

-

-

-

... More
Institute Building

500

-

-

... More
Hostel Building

-

-

-

... More
Supply and fixing powder coated MS raceways junction boxes on surface of walls/celing and/ or recessed in walls/ floors fabricated from 2mm thick MS sheets provided with neproence gasketted removable cover fixed on athe boxes by countersunk cadmium plated screws at intervals of max.300mm including the cost of earth links at all joints to ensure earth continuity and including athe cost of powder coating as colour to be approved complete as per specifications as required and as below:

-

-

-

... More
350x350mm wide x 50mm deep

-

-

-

... More
Institute Building

15

-

-

... More
Hostel Building

-

-

-

... More
250x250mm wide x 50mm deep

-

-

-

... More
Institute Building

25

-

-

... More
Hostel Building

-

-

-

... More
Wiring for group controlled (looped) light point / fan point /exhaust fan point/ call bell point (without independent switch) with 1.5 Sqm.m FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch,modular plate ,suitable GI Box and earthing the point with 1.5 Sqm.m FR PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

-

-

-

... More
Institute Building

300

-

-

... More
Hostel Building

85

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos. 3 pin 5/6 amps modular socket outlet and 2nos. 5/6 amps modular switch ,connection etc as required. (For Light plugs to be used in Non Residential buildings)

-

-

-

... More
Institute Building

115

-

-

... More
Hostel Building

230

-

-

... More
Supplying,installing,testing and commissioing of Passive Infrared (PIR) technology based occupancy sensors having high performance, non regulating programmable type suitable for connected load upto 10 amp, for mounting height upto 2.8mtr and for 5 meter diameter covergae along with necessary fixing arrnagements i/c programming at site etc. complete as required.

-

-

-

... More
Institute Building

80

-

-

... More
Hostel Building

10

-

-

... More
DISTRIBUTION BOARDS

-

-

-

... More
Supplying and fixing following way prewired TP & N, MCB distribution board of sheet steel for 415 volts on surface /recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper condutor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isoltor).

-

-

-

... More
4 way (4+12) Double door

-

-

-

... More
Institute Building

5

-

-

... More
Hostel Building

2

-

-

... More
6 way (4+18) Double door

-

-

-

... More
Institute Building

14

-

-

... More
Hostel Building

1

-

-

... More
8 way (4+24) Double door

-

-

-

... More
Institute Building

4

-

-

... More
Hostel Building

12

-

-

... More
Supplying and fixing following way, single pole and neutral, prewired, sheet steel, MCB distribution board, 240 volts, on surface /recess, complete with loose wire box, terminal blocks, duly prewired with suitable size FR PVC insulated copper condutor upto terminal blocks, tinned copper bus bar, neutral link, earth bus, din bar, detachable gland plate, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
8 way Double door

-

-

-

... More
Institute Building

2

-

-

... More
Hostel Building

1

-

-

... More
4 way (4+12) Double door

-

-

-

... More
Institute Building

1

-

-

... More
Hostel Building

1

-

-

... More
Supply and fixing 5 amps to 32 amps rating.240/415 volts.'C' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commisioning etc.as required

-

-

-

... More
Single pole

-

-

-

... More
Institute Building

334

-

-

... More
Hostel Building

342

-

-

... More
tripple pole

-

-

-

... More
Institute Building

6

-

-

... More
Hostel Building

6

-

-

... More
Supply and fixing following rating,four pole (three phase and neutral), 415 volts,RCBO having a sensitivity current upto 300 amp in the existing MCB DB complete with connection ,testing and commissioning etc. as required.

-

-

-

... More
63 amps

-

-

-

... More
Institute Building

17

-

-

... More
Hostel Building

15

-

-

... More
Supply and fixing following rating,double pole (single phase and neutral),240 volts,RCBO having a sensitivity current upto 300 amp in the existing MCB DB complete with connection ,testing and commissioning etc. as required.

-

-

-

... More
40 amps

-

-

-

... More
Institute Building

8

-

-

... More
Hostel Building

1

-

-

... More
Supply and fixing following rating,foure pole 415 volts, Isolater in the existing MCB DB complete with connection ,testing and commissioning etc. as required.

-

-

-

... More
100 amps

-

-

-

... More
Institute Building

8

-

-

... More
Hostel Building

1

-

-

... More
WIRING FOR TELE. & DATA POINTS

-

-

-

... More
Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
75 mm x 75 mm x 60 mm deep

-

-

-

... More
Institute Building

215

-

-

... More
Hostel Building

22

-

-

... More
Supplying and drawing following pair, 0.5.mm dia FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
2 Pair

-

-

-

... More
Institute Building

900

-

-

... More
Hostel Building

250

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding plate etc .as required.

-

-

-

... More
Telephone socket outlet

-

-

-

... More
Institute Building

85

-

-

... More
Hostel Building

16

-

-

... More
TV antenna socket outlet

-

-

-

... More
Institute Building

5

-

-

... More
Hostel Building

4

-

-

... More
Data outlet one module for Data Points (RJ-45)

-

-

-

... More
Institute Building

125

-

-

... More
Hostel Building

2

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
Institute Building

200

-

-

... More
Hostel Building

150

-

-

... More
Supplying and fixing of the following sheet steel clad wall / recess mounting telephone tag blocks of krone make constructed from 14 SWG sheet steel finished with red oxide coating of two coats of paint with hinged gasketted powder coated door and complete.

-

-

-

... More
10 pairs

-

-

-

... More
Institute Building

1

-

-

... More
Hostel Building

2

-

-

... More
20 pairs

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

1

-

-

... More
50 pairs

-

-

-

... More
Institute Building

2

-

-

... More
Hostel Building

-

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required

-

-

-

... More
1 Run of cable

-

-

-

... More
Institute Building

3000

-

-

... More
Hostel Building

50

-

-

... More
Providing and fixing of patch cords 1mtr length complete as required.

-

-

-

... More
Institute Building

125

-

-

... More
Hostel Building

-

-

-

... More
EARTHING

-

-

-

... More
Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charoal or coke and salt as required.

-

-

-

... More
Institute Building

10

-

-

... More
Hostel Building

6

-

-

... More
Providing & fixing 25mm x 5mm GI Strip in 40mm dia GI pipe from earth elecrode including connections with GI nut, bolt, spring, washer excavation and re-fiiling etc. as required.

-

-

-

... More
Institute Building

150

-

-

... More
Hostel Building

100

-

-

... More
Providing & fixing 25mm x 5mm GI Strip on surface / recess for loop earthing as required.

-

-

-

... More
Institute Building

450

-

-

... More
Hostel Building

200

-

-

... More
Providing & fixing of 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.

-

-

-

... More
Institute Building

350

-

-

... More
Hostel Building

250

-

-

... More
LIGHTING FIXTURE AND FANS

-

-

-

... More
Supplying & fixing of following type recessed / surface mounted LED light fixture complete with driver, earthing point etc. complete as required. (Havells or equivalent)

-

-

-

... More
15W LED Downlighter

-

-

-

... More
Institute Building

332

-

-

... More
Hostel Building

155

-

-

... More
b) 20W LED Tube

-

-

-

... More
Institute Building

42

-

-

... More
Hostel Building

38

-

-

... More
c) 18W LED Tube

-

-

-

... More
Institute Building

65

-

-

... More
Hostel Building

138

-

-

... More
d) 12W LED Downlighter

-

-

-

... More
Institute Building

64

-

-

... More
Hostel Building

235

-

-

... More
e) 9W LED Tube (2')

-

-

-

... More
Institute Building

22

-

-

... More
Hostel Building

315

-

-

... More
f) 10W LED Downlighter

-

-

-

... More
Institute Building

60

-

-

... More
Hostel Building

110

-

-

... More
g) 10W LED Bulk Head

-

-

-

... More
Institute Building

5

-

-

... More
Hostel Building

12

-

-

... More
h) 36W LED Panel (2'x2')

-

-

-

... More
Institute Building

140

-

-

... More
Hostel Building

-

-

-

... More
Supplying installation,testing & commisioning of 305 mm 1400 RPM exhaust fan complete with louver and bird guard screen with 3 core flexible wire as required.

-

-

-

... More
Institute Building

17

-

-

... More
Hostel Building

118

-

-

... More
Supplying installation,testing & comisioning of ceiling fan, complete with blades with suitable length of down rods shackle insulator earthing point including connection etc . as required.

-

-

-

... More
1200 mm sweep

-

-

-

... More
Institute Building

205

-

-

... More
Hostel Building

141

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.

-

-

-

... More
Institute Building

141

-

-

... More
Hostel Building

141

-

-

... More
FIRE ALARM SYSTEM

-

-

-

... More
SITC of Fire Alarm System with following components.System shall be able to make announcement to all the floors simultaneously and individualy.

-

-

-

... More
Supplying and drawing of FR PVC insulated copper conductor single core cable of 2x1.5 Sqm.m. in existing conduit as required.

-

-

-

... More
Institute Building

5250

-

-

... More
Hostel Building

-

-

-

... More
Supplying, installation, testing and commissioning of inteligent analouge photoelectric optical type smoke detector and mounting base with LED light complete as required.

-

-

-

... More
Institute Building

210

-

-

... More
Hostel Building

-

-

-

... More
Supplying, installation, testing and commissioning of inteligent analouge photoelectric optical type heat detector and mounting base with LED light complete as required.

-

-

-

... More
Institute Building

5

-

-

... More
Hostel Building

-

-

-

... More
Supplying, installation, testing and commissioning of duel tone electronic hooter suitable for wall mounted complete as required.

-

-

-

... More
Institute Building

9

-

-

... More
Hostel Building

-

-

-

... More
Supplying, installation, testing and commissioning of manual call box in suitable enclosure with arrangement to raise the alarm when the glass is manually broken complete as required.

-

-

-

... More
Institute Building

9

-

-

... More
Hostel Building

9

-

-

... More
Supply, testing and commissioning of Microprocessor based intelligent and electronically addressable, modular, expandable networkable, 4 Loop fire alarm control panel cum Emergency voice evacuation system with amplifier, mike etc. with Liquid Crystal Display, multiple access levels with historic event. loop should have be 20% spare. The panel shall have 240 volts AC power supply, automatic battery Charger, 24 volts batteries sufficient for operating the system for 60 minutes during emergency condition.

-

-

-

... More
Institute Building

1

-

-

... More
Supplying, installing, testing and commissioning of Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept / reset buttons for alarm address of any sensor / field device. The Repeater Panel shall only provide field device address with number.

-

-

-

... More
Institute Building

1

-

-

... More
Hostel Building

-

-

-

-

-

-

... More
SITC of the following Digital CCTV System including outlet boxes, cover plates and all necessary connections complete with operation, testing and commissioning works.

-

-

-

... More
Supply installation Testing and Commissioing of Indoor 1.3 megapixel wide angle Dome camera with 3.6mm builting fixed lens with minimum illumination of 0.1 lux F1.2 50IRE with IR LEDs with SSDR, SSNR and ICR for making it true day & night camera with intelligent motion detection and occlusion detection.

-

-

-

... More
Institute Building

20

-

-

... More
Hostel Building

5

-

-

... More
Supply installation Testing and Commissioing of Indoor 1.3 megapixel wide angle Bullet camera with 3.6mm builting fixed lens with minimum illumination of 0.1 lux F1.2 50IRE with IR LEDs with SSDR, SSNR and ICR for making it true day & night camera with intelligent motion detection and occlusion detection.

-

-

-

... More
Institute Building

15

-

-

... More
Hostel Building

5

-

-

... More
Supply installation Testing and Commissioing of Outdoor 1.3 megapixel wide angle bullet camera with 8mm builting fixed lens with minimum illumination of 0.1 lux F1.2 50IRE with IR LEDs with SSDR, SSNR and ICR for making it true day & night camera with intelligent motion detection and occlusion detection with IP 66 weatherproof housing (Around the premises)

-

-

-

... More
Institute Building

4

-

-

... More
Hostel Building

2

-

-

... More
SITC 16-Ch Digital Video Recorder, with 25FPS per camera with built in multipixer, Display/Record rate 200fps (PAL), H-264 Video Compression,high quality Continuous, Motion & Schedule Recording 24 hours, Supportable with SATA interface upto 2 TB, HDMI output with Audio, Mic attachable, Backup on USB, Remote Monitring via LAN/WAN.

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

1

-

-

... More
Supply, Installatin, Testing and Commissioning of 12 V DC, Digital technology based Power Supply Units highly regulated and spikes free terminal voltage and heavy sourcing current for regulated terminal voltage.

-

-

-

... More
Institute Building

39

-

-

... More
Hostel Building

15

-

-

... More
Supply, Installatin, Testing and Commissioning of 26" LED High resolution, High contrast ratio Color LED Monitor.

-

-

-

... More
Institute Building

4

-

-

... More
Hostel Building

2

-

-

... More
Supply and laying of Video Cable : RG-6 in existing conduit complete as required

-

-

-

... More
Institute Building

1500

-

-

... More
Hostel Building

500

-

-

... More
SITC of Internal SATA 1 Tb hard disk complete as required

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

-

-

-

... More
Supplying and drawing of FR PVC insulated copper conductor single core cable of 2x1.5 Sqm.m. in existing conduit as required.

-

-

-

... More
Institute Building

3000

-

-

... More
Hostel Building

1000

-

-

... More
SITC of 600VA UPS with 15mins back-up complete as required.

-

-

-

... More
Institute Building

1

-

-

... More
Hostel Building

1

-

-

-

-

-

... More
Supply, Installation, Testing & Comissioning of 40 Kva (make: APC, Emersion, V-Guard or equivalent) true Online Smart UPS System with(3-Ph In & 3-Ph out) VRLA Sealed maintenance free battery with independent 12V units cell banks of capacity designed for end cell 12V/65 AH X 32 nos Nos. UPS for 15 Min Back Up Rack & Interlink Cable included.

-

-

-

... More
Institute Building

1

-

-

... More
EXTERNAL ELECTRICAL WORKS

-

-

-

... More
L.T. PANELS

-

-

-

... More
LT cum EMG PANEL

-

-

-

... More
INCOMER - 1 (TRANSFORMER - 630 KVA)

-

-

-

... More
1 No. 800A, 4P EDO ACB (50KA) with protections E/F,O/L,S/C release, U/V, shunt release, with NO & NC Auxiliary contacts.

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
3 Nos. 800/5A ratio CTs 15 VA Class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
under voltage protection

-

-

-

... More
over voltage protection

-

-

-

... More
IDMT protection

-

-

-

... More
Reverse Power protection

-

-

-

... More
Master Trip protection

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with 2A SP MCB.

-

-

-

... More
INCOMER - 2 (300 KVA DG SET)

-

-

-

... More
1 No. 630A, 4P EDO ACB (50 KA)with protections E/F,O/L,S/C release, U/V, shunt release, with NO & NC Auxiliary contacts.

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
3 Nos. 630/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
under frequency protection

-

-

-

... More
over frequency protection

-

-

-

... More
under voltage protection

-

-

-

... More
over voltage protection

-

-

-

... More
IDMT protection

-

-

-

... More
Reverse Power protection

-

-

-

... More
Master Trip protection

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with 2A SP MCB.

-

-

-

... More
Bus Couplar between Section 1& 2

-

-

-

... More
250A, 4P MCCB bus couplar with protections.

-

-

-

... More
1 No. U/V release

-

-

-

... More
1 Set of control fuses & control terminals

-

-

-

... More
1 Set of ON/OFF/TRIP indication lamp.

-

-

-

... More
INCOMER - 3 (160 KVA DG SET)

-

-

-

... More
1 No. 250A, 4P MCCB (25 KA)with protections E/F,O/L,S/C release, U/V, shunt release, with NO & NC Auxiliary contacts.

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
3 Nos. 250/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
under frequency protection

-

-

-

... More
over frequency protection

-

-

-

... More
under voltage protection

-

-

-

... More
over voltage protection

-

-

-

... More
IDMT protection

-

-

-

... More
Reverse Power protection

-

-

-

... More
Master Trip protection

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with 2A SP MCB.

-

-

-

... More
Bus Couplar between Section 2 & 3

-

-

-

... More
250A, 4P MCCB bus couplar with protections.

-

-

-

... More
1 No. U/V release

-

-

-

... More
1 Set of control fuses & control terminals

-

-

-

... More
1 Set of ON/OFF/TRIP indication lamp.

-

-

-

... More
INCOMER - 4 (100 KVA DG SET)

-

-

-

... More
1 No. 200A, 4P MCCB (16 KA)with protections E/F,O/L,S/C release, U/V, shunt release, with NO & NC Auxiliary contacts.

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
3 Nos. 200/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
under frequency protection

-

-

-

... More
over frequency protection

-

-

-

... More
under voltage protection

-

-

-

... More
over voltage protection

-

-

-

... More
IDMT protection

-

-

-

... More
Reverse Power protection

-

-

-

... More
Master Trip protection

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with 2A SP MCB.

-

-

-

... More
Bus Bar

-

-

-

... More
1000 & 300 Amp TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings

-

-

-

... More
Two (2) Nos. 630Amp 4P MCCB (35 KA)

-

-

-

... More
One (1) No. 250Amp 4P MCCB (25 KA)

-

-

-

... More
Two (2) Nos. 125Amp 4P MCCB (16 KA)

-

-

-

... More
Four (4) Nos. 100Amp 4P MCCB (16 KA)

-

-

-

... More
Four (4) Nos. 63Amp 4P MCCB (16 KA)

-

-

-

... More
Four (2) Nos. 40Amp 4P MCCB (16 KA)

1

-

-

... More
HOSTEL LIGHT PANEL

-

-

-

... More
INCOMER-2 Nos (From LT cum EMG Panel & Solar PV) Nos. comprising of

-

-

-

... More
1 no. 125A 4P MCCB

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of MFM for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
1 No.125/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.

-

-

-

... More
Manual Change Over Switch

-

-

-

... More
1 No. 125 A 4P Manual Change Over Switch , operating Handle with other required accessories & interconnections complete in all respects as required.

-

-

-

... More
Bus Bar

-

-

-

... More
150A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Three (3) Nos. 100Amp 4P MCCB (16 KA)

-

-

-

... More
Two (2) Nos. 80Amp 4P MCB/MCCB (10/16 KA)

-

-

-

... More
Five (5) Nos. 63Amp 4P MCB (10 KA)

1

-

-

... More
TYPICAL SDB HOSTEL FLOOR POWER PANEL

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 100A 4P MCCB

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
Incomer shall have the following indicating panel.

-

-

-

... More
96mm sq. flush voltmeter scaled 0-500 volt with 3 way and OFF selector switch.

-

-

-

... More
Three nos. 100/5 class 1.0 accuracy 15 VA burden C.T.s for metering.

-

-

-

... More
96 mm square flush ammeter scaled 0-100 amps with 3 way and OFF selector switch.

-

-

-

... More
Three phase indicating lights.

-

-

-

... More
3nos. 2A SP Control MCB

-

-

-

... More
Bus Bar

-

-

-

... More
100A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Four (4) Nos. 63Amp 4P MCB (10 KA)

2

-

-

... More
HOSTEL POWER PANEL

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 250A 4P MCCB

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of MFM for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
1 No.250/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.

-

-

-

... More
Bus Bar

-

-

-

... More
300A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Three (3) Nos. 125Amp 4P MCCB (16 KA)

-

-

-

... More
Five (5) Nos. 80Amp 4P MCB/MCCB (10/16 KA)

1

-

-

... More
TYPICAL SDB HOSTEL FLOOR POWER PANEL

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 125A 4P MCCB

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
Incomer shall have the following indicating panel.

-

-

-

... More
96mm sq. flush voltmeter scaled 0-500 volt with 3 way and OFF selector switch.

-

-

-

... More
Three nos. 125/5 class 1.0 accuracy 15 VA burden C.T.s for metering.

-

-

-

... More
96 mm square flush ammeter scaled 0-125 amps with 3 way and OFF selector switch.

-

-

-

... More
Three phase indicating lights.

-

-

-

... More
3nos. 2A SP Control MCB

-

-

-

... More
Bus Bar

-

-

-

... More
150A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Five (5) Nos. 80Amp 4P MCB/MCCB (10 KA)

2

-

-

... More
INSTITUTE MAIN PANEL

-

-

-

... More
INCOMER-I (From LT cum EMG Panel)

-

-

-

... More
1 no. 630A 4P MCCB with O/L, S/C & E/F

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of MFM for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
1 No.630/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.

-

-

-

... More
INCOMER-II (Solar PV)

-

-

-

... More
1 no. 125A 4P MCCB with O/L, S/C & E/F

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of MFM for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
1 No.125/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.

-

-

-

... More
1 No Bus coupler Comprising of

-

-

-

... More
One(1) No - 125A, 4P MCCB With shunt trip release and Castel Key Mechanial interlocking with both incoming feeders as required.

-

-

-

... More
Bus Bar

-

-

-

... More
800A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Three (3) Nos. 400Amp 4P MCCB (25 KA)

-

-

-

... More
Four (4) Nos. 100Amp 4P MCCB (16 KA)

-

-

-

... More
Seven (8) Nos. 63Amp 4P MCB (10 KA)

1

-

-

... More
TYPICAL FLOOR PANEL-INSTITUTE

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 100A 4P MCCB

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
Incomer shall have the following indicating panel.

-

-

-

... More
96mm sq. flush voltmeter scaled 0-500 volt with 3 way and OFF selector switch.

-

-

-

... More
Three nos. 100/5 class 1.0 accuracy 15 VA burden C.T.s for metering.

-

-

-

... More
96 mm square flush ammeter scaled 0-100 amps with 3 way and OFF selector switch.

-

-

-

... More
Three phase indicating lights.

-

-

-

... More
3nos. 2A SP Control MCB

-

-

-

... More
Bus Bar

-

-

-

... More
150A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Eight (8) Nos. 63Amp 4P MCB (10 KA)

2

-

-

... More
INSTITUTE AC PANEL

-

-

-

... More
INCOMER

-

-

-

... More
1 no. 320A 4P MCCB with O/L, S/C & E/F

-

-

-

... More
Incomer Metering & Protection.

-

-

-

... More
1 Set of MFM for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
1 No.400/5A ratio CTs 15 VA class 5P 10

-

-

-

... More
3 Nos. phase indicating lights with control fuses.

-

-

-

... More
1 Set of control fuses & control terminals.

-

-

-

... More
3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB.

-

-

-

... More
Bus Bar

-

-

-

... More
400A TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp Sqm.m. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip.

-

-

-

... More
Outgoings :

-

-

-

... More
Eight (8) Nos. 100Amp 4P MCCB (25 KA)

1

-

-

... More
TYPICAL LIFT PANEL (HOSTEL & INSTITUTE)

-

-

-

... More
INCOMING

-

-

-

... More
1 no. 100A 16 kA 4P MCCB

-

-

-

... More
BUS BAR

-

-

-

... More
Electrolytc high conductivity aluminium three phase and neutral busbars rated at 100 A. having a maximum current density of 1 amp. Per Sqm.m. Suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The netutral busbars is to be of 50% capacity.

-

-

-

... More
INDICATING PANEL

-

-

-

... More
Incomer shall have the following indicating panel.

-

-

-

... More
96mm sq. flush voltmeter scaled 0-500 volt with 3 way and OFF selector switch.

-

-

-

... More
Three nos. 100/5 class 1.0 accuracy 15 BA burden C.T.s for metering.

-

-

-

... More
96 mm square flush ammeter scaled 0-100 amps with 3 way and OFF selector switch.

-

-

-

... More
Three phase indicating lights.

-

-

-

... More
3nos. 2A SP Control MCB

-

-

-

... More
OUTGOING UNITS

-

-

-

... More
3 nos. 63A 10 kA TP MCB

-

-

-

... More
9 nos. 40A 10 kA DP MCB

2

-

-

... More
CAPACITOR PANEL(200KVAR)

-

-

-

... More
Design, Supplying and erection at site with chanel frmae. grouting etc. complete in al aspects of the following intergrated cubical type indoor automatic switching "ON" and "OFF" control panel with dust vermin proof lined locable doors complete with interconnection stepped relays contractors Push button and CTS complete with a capacitor bank as per specification (suitable for 400/440V 3 phase 50 C/S supply system) as required.

-

-

-

... More
INCOMING

-

-

-

... More
320A TP+N MCCB -1 No.

-

-

-

... More
PHASE INDICATION lamps Nos. backed up with 5A unit to indicate that the unit is "ON" - 11 Set

-

-

-

... More
Indication lamp to Nos. 50 KVAR capacitor unit to indicate that the unit (MPP type) is"ON" - 01 Nos.

-

-

-

... More
Indication lamp to Nos. 25 KVAR capacitor unit to indicate that the unit (MPP type) is"ON" - 3 Nos.

-

-

-

... More
Indication lamp to Nos. 15 KVAR capacitor unit to indicate that the unit (MPP type) is"ON" - 3 Nos.

-

-

-

... More
Indication lamp to Nos. 10 KVAR capacitor unit to indicate that the unit (MPP type) is"ON" - 2 Nos.

-

-

-

... More
Indication lamp to Nos. 05 KVAR capacitor unit to indicate that the unit (MPP type) is"ON" - 2 Nos.

-

-

-

... More
1 Set of MFM (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697

-

-

-

... More
320/5A CTS Ratio -1 Set.

-

-

-

... More
APFC Relay -1Set.

-

-

-

... More
Power factor meter -1 Set.

-

-

-

... More
Outgoings

-

-

-

... More
100A MCCB with contractor to Nos. 50 KVAR capacitor - 01 No.

-

-

-

... More
63A MCB with contractor to Nos. 25 KVAR capacitor - 3 Nos.

-

-

-

... More
40A MCB with contractor to Nos. 15 KVAR capacitor - 3 Nos.

-

-

-

... More
40A MCB with contractor to Nos. 10 KVAR capacitor - 2 Nos.

-

-

-

... More
25A MCB with contractor to Nos. 05 KVAR capacitor - 2 Nos.

-

-

-

... More
Push button stations "RED" and "GREEN" push button for manual operation of contractor - 20 Set

-

-

-

... More
Automatic switching "ON" and "OFF" control panels as described

-

-

-

... More
50 KVAR capacitor bank - 01 No.

-

-

-

... More
25 KVAR capacitor bank - 03 Nos.

-

-

-

... More
15 KVAR capacitor bank - 03 Nos.

-

-

-

... More
10 KVAR capacitor bank - 02 Nos.

-

-

-

... More
05 KVAR capacitor bank - 02 Nos.

-

-

-

... More
All interconnections from bus bar to connectors and connectors to terminal

1

-

-

... More
UPS PANEL(For Institute Building)

-

-

-

... More
One (1) Incomer- 63 Amp TPN ,25 KA MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB Digital Voltmeter and Ammeter with selector switch

-

-

-

... More
Busbar - 100 Amp,25KA Cu TP2N busbar suitable for operation at 415 Volt, 50 Hz, 3 Phase supply

-

-

-

... More
Eight(8) - Outgoing Feeders for (6 Nos of UDB, One Server Rack & one spares) Nos. Comprising of

-

-

-

... More
One (1) - 32 Amp 4P, 10 KA MCB

-

-

-

... More
Four (4) - Outgoing Feeders (One CCTV, One Fire Alarm wih PA System, One ELV System & One spare) Nos. comprising of

-

-

-

... More
One (1) 25 Amp, 10 KA DP MCB

-

-

-

... More
PANEL AS ABOVE

1

-

-

... More
STREET LIGHT PANEL

-

-

-

... More
Design & Supply of cubicle type, LT outdoor feeder pillar, double door fully compartmentalised, dust and vermin proof, made out of 2 m.m. thick CRCA sheet steel, floor mounted, free standing, lockable, confirming to IP- 55, mounted on finished brick foundation, powder coated/ epoxy painted, cable entry from bottom, with following configuration- (FP)

-

-

-

... More
MCCB's shall be Ics = 100% Icu

-

-

-

... More
STREET LIGHT

-

-

-

... More
INCOMER :-

-

-

-

... More
63A 4P MCCB

-

-

-

... More
100A TPN+E Aluminium bus bar

-

-

-

... More
Suitable cable gland for 4.0Cx 16 sq. mm.

-

-

-

... More
OUTGOING :-

-

-

-

... More
10A SP MCB - 10 Nos.

-

-

-

... More
40A 4P MCB - 1 Nos.

-

-

-

... More
40A DP MCB - 2 Nos.

-

-

-

... More
Timer & Contactor - 1 Set

2

-

-

... More
EARTHING

-

-

-

... More
SITC of Bentonite filled chemical Earthing with G.I. earth rod 58mm x 3m including accessories, and providing masonry enclosure with cover plate having locking arrangement complete as required as required.

44

-

-

... More
SITC of Bentonite filled chemical Earthing with Cu earth rod 58mm x 3m including accessories, and providing masonry enclosure with cover plate having locking arrangement complete as required as required.

8

-

-

... More
Providing and fixing 25mm x 5mm copper strip in 40mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc as required.

120

-

-

... More
Providing and fixing 25mm x 5mm GI strip in 40mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc as required.

280

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

200

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

1165

-

-

... More
Providing and fixing 6 SWG dia GI wire on surface or in reccess for loop earthing as required.

1500

-

-

... More
L.T. CABLES XLPE (IS:7098)

-

-

-

... More
(Exact Lengths to be measured at site before execution)

-

-

-

... More
Supplying of following sizes of XLPE PVC insulated PVC sheathed armoured alminum conductor power cable of 1.1 KV grade as required

-

-

-

... More
3.5 C x 400 Sqm.m

140

-

-

... More
3.5 C x 240 Sqm.m

400

-

-

... More
3.5 C x 185 Sqm.m

280

-

-

... More
3.5 C x 95 Sqm.m

360

-

-

... More
3.5 C x 70 Sqm.m

170

-

-

... More
4 C x 50 Sqm.m

70

-

-

... More
4 C x 25 sq mm

140

-

-

... More
4 C x 16 sq mm

250

-

-

... More
4 C x 6 Sqm.m

3250

-

-

... More
4 C x 4 Sqm.m

80

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in gorund including excavation sand cushioning, protective covering, and refilling the trench as required.

-

-

-

... More
Upto 25 sq. mm

3720

-

-

... More
Above 25 sq. mm and upto 120 sq. mm

600

-

-

... More
Above 120 sq. mm and upto 400 sq. mm

820

-

-

... More
MV CABLE JOINTING & END TERMINATION

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5 C x 400 Sqm.m

8

-

-

... More
3.5 C x 240 Sqm.m

8

-

-

... More
3.5 C x 185 Sqm.m

2

-

-

... More
3.5 C x 95 Sqm.m

2

-

-

... More
3.5 C x 70 Sqm.m

2

-

-

... More
4 C x 50 Sqm.m

2

-

-

... More
4 C x25 sq mm

8

-

-

... More
4 C x16 sq mm

6

-

-

... More
4 C x 6 Sqm.m

100

-

-

... More
4 C x 4 sq mm

2

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930 part II complete with fiitng and cutting jointing etc. direct in ground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.

-

-

-

... More
63mm dia

80

-

-

... More
120mm dia

140

-

-

... More
200mm dia

70

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Supplying of non-skid rubber mat 12mm thick and 1000mm width as required including cutting to required lengths of approved make with test certificates for 440 V L.T. switchgears conforming to IS/IE code..

20

-

-

... More
Supplying of fire bucket with sand, painted red and approved quality conforming to IS : 2546/1974.

3

-

-

... More
Supplying of MS stand duly painted suitable for supporting two buckets ( Pedestal type )

3

-

-

... More
Supplying and fixing carbon dioxide fire extinguisher type 4 Kgs capacity of approved make with wall mounting bracket as required conforming to IS : 2878/1976.

3

-

-

... More
Supplying of first aid box as approved complete with standard kit as prescribed by Indian Red cross.

2

-

-

... More
S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work.

3

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, at least 2 mm thick and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required .

3

-

-

... More
STREET LIGHTING

-

-

-

... More
Supplying and fixing of 6M (1m in & 5m out) GI Poles as per IS-1161 with latest amendment complete with top section suitable with 1.5mtr single arm Bracket with 250x250x12mm MS base plate including PU paint after chemical traetment and CKT marking as per drawing.Tthe pole to be erected on cement concrete foundation of 1:2:4 with collar including 16A DP MCB & Busbar & excavatiom in all type of soil as required & as per drawing.

35

-

-

... More
Supplying and fixing of 4M (1m in & 3m out) GI Poles as per IS-1161 with latest amendment complete with 200x200x12mm MS base plate including PU paint after chemical traetment and CKT marking as per drawing.Tthe pole to be erected on cement concrete foundation of 1:2:4 with collar including 16A DP MCB & Busbar & excavatiom in all type of soil as required & as per drawing.

20

-

-

... More
Supplying and fixing of intergrated street light fitting with 60W LED lamp complete including supply, wiring and connection with 3x2.5Sqm.m. PVC insulated stranded copper conductor and for earthing as required.

35

-

-

... More
Supplying and fixing of Post Top street light fitting with 25W LED lamp complete including supply, wiring and connection with 3x2.5Sqm.m. PVC insulated stranded copper conductor and for earthing as required.

20

-

-

... More
Earthing with 4.5M long 'B' class 40mm dia GI pipe including all accessories and providning cover plate complete with hinges locking arrangement at the top with salt and charcoal etc. complete as required.

2

-

-

... More
Supplying & fixing in position 0.5 M long 50 mm class - B GI pipe suitable for mounting 18W GATE light luminaries as received and complete in all aspects as required.

4

-

-

... More
Supplying and fixing Gate light 18W Lamp, complete including supply, wiring and connection . PVC insulated stranded copper conductor and for earthing complete as required.

4

-

-

... More
Supplying,testing & Commissioing of IP66 rating 30W LED Solar Street Light with Tublar pole 6 M long with latest amendment complete with top section with 250x250x12mm MS base plate including light fixtute, one coat of red oxide and two coat of aluminium paint and CKT marking as per drawing and specification. The pole to be erected on cement concrete foundation of 1:2:4 with collar including MCB & Busbar & excavatiom in all type of soil as required. Also with 100AH Solar Battery with Charger in acid proof powder coated battery box. Solar street lighting system shall complete with all accesories etc as required to complete the job & shall follow IEC 61215, IEC61730, IEC61701 standard & have TUV & CE certified.

10

-

-

... More
Supplying and fixing of IP 65 rating 100W Flood Light complete including supply, wiring and connection with 3x2.5Sqm.m. PVC insulated stranded copper conductor and for earthing as required.

4

-

-

... More
DG SET

-

-

-

... More
Supply, Fixing, testing and Commissioning of following KVA Rating Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, with AMF Control, 0.85 load factor including sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB-II norms) fabricated out of CRCA sheet of 14 / 16 SWG thickness with min. 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. Should be synchronize compatable (Testing of DG sets should be done as per specified in Technical specification).

-

-

-

... More
The canopy should be designed in such a way that the Noise level is not nore than 75 DB level at a distance of 1 meter away from the DG set as per Indian standards.

-

-

-

... More
Diesel Engine -

-

-

-

... More
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo Charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 1000 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.

-

-

-

... More
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :

-

-

-

... More
Start stop switch with key

-

-

-

... More
Water temperature indication

-

-

-

... More
Lubrication oil pressure indication.

-

-

-

... More
Lubrication oil temperature indication.

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over speed indication

-

-

-

... More
Low Lube oil trip indication

-

-

-

... More
Engine hours indication

-

-

-

... More
The DG set should be supplied with cable end box to terminate 2x3.5x400sq mm size of cables on alternator complete as required.

-

-

-

... More
Alternator -

-

-

-

... More
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 1000 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required.

-

-

-

... More
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.

-

-

-

... More
The DG set is to be installed on the ground floor on by making the foundation (done by the supplier/contactor only). Unloading , loading , and installation shall be in the scope of contractor.

-

-

-

... More
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete. Apart from inbuilt tank 990 liters day tanks treated with anti corrisive treatment to be provided with Nos. DG set

-

-

-

... More
Fuel oil required for testing the DG set as per IS Shall be supplied by the contractor.

-

-

-

... More
Tank shall be Provided with Low/High level sensor and alarm indication.

-

-

-

... More
Exhaust System - Exhaust manifold with silencer complete with mineral wool / rock wool insulation on all sides, with chicken mesh wrapping and aluminium sheet cladding complete as required.(Minimum Height : 15 meter)

-

-

-

... More
The D G set should be supplied with required hardware for external PLC based auto load management system.

-

-

-

... More
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.

-

-

-

... More
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.

-

-

-

... More
300 KVA

1

-

-

... More
160 KVA

1

-

-

... More
100 KVA

1

-

-

... More
ENERGY MANAGEMENT SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of following items for energy management system.

-

-

-

... More
Web Based Energy Management & Reporting Tool software for Monitoring Building efficiency and store the data into separate application database (SQL server) for analysis. The Information should be available as "Screen In Dashboards, This Software should have the following Key features: 1. User Defined dashboard. Any Number of dashboard can be added by user . 2. Universal Dashboard: Ability to create dashboard for any point and monitor/compare it with any /multiple points as a function of time. 3. Monthly Calender Dashboard: Monitor the demand/ consumption pattern for all days in a a month in a single screen. 4.Segmentation of Energy Information at a glance 5. Web based tool . 5. EMAIL OPTION AVAILABLE 6. Mobile Platform: IPAD/ Android Compatible.

1

-

-

... More
Data converter having RS 485 port as input for modbus and Ethernet port as output. The converter shall support atleast 25 dual source meters. Also it should have Breaker Status Communication Module (On/off/trip) complete with wall mounted encloasure for 25 Nos of breaker having Ethernet port for comunication.

1

-

-

... More
Workstation with Intel core i5 processors (Latest Technology), Windows 7 or higher operating System, 1 TB HDD, 4 GB RAM, Enhanced graphic Card, DVD Combo Drive, Ethernet Port with microsoft office and anti virus as per Specification. 21" monitor and A4 laser printer shall be included in this

1

-

-

... More
Twisted pair shielded PVC jacket EIA Industrial RS 485 cable Beldon make 22 AWG complete as required including terminations

1000

-

-

... More
8 Port Ethernet Switch

3

-

-

... More
Rack for Mounting switch

3

-

-

... More
Cat6 cable

1000

-

-

... More
25mm PVC Conduit

1000

-

-

... More
NET METERING SOLAR SUPPLY SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of Net metering grid interactive roof top solar photo voltaic power generation system I/C space frame as described below and any other items required.

-

-

-

... More
1Set Solar PV Modules Type - Poly-Crystalline Si Rating - 250 Wp @ STC

-

-

-

... More
1 Set Module Mounting Structure Details - Suitable to Mount 20 KWp PV array

-

-

-

... More
1 No. Grid Tie Inverter Rating –20 Kw

-

-

-

... More
1 Set. AC and DC Cables (of appropriate rating )

-

-

-

... More
1 Set. Earthing Type- Chemical earthing

-

-

-

... More
1 No. Lighting Arrester

-

-

-

... More
AC Distribution Board (with MCB/MCCB, Indicators, Buzzer etc) (Lump Sum)

-

-

-

... More
Miscellanious items like Cable lugs, Ties, cable trays (if required), Earthing strips, MC4 connector pairs, thimbles, conduits etc. (Lump Sum)

2

-

-

... More
LIGHTNING PROTECTION & AVIATION LIGHT

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, Copper tube, having single prong at top, with 85 mm dia 6 mm thick copper base plate including holes etc. along with Test junction complete as required.

-

-

-

... More
Institute Building

40

-

-

... More
Hostel Building

50

-

-

... More
Supply,testing & commissioning of Aviation obstruction light with LED lamp, control gear, including 38 mm dia class B G I pipe of suitable length with all accessories as per standard item.

2

-

-

... More
LANDSCAPE LIGHTING

-

-

-

... More
Supplying, installation testing and commissioning following type of light fixtures with all accessories as required.(Make: Phillips, Wipro, CG or equivalent)

-

-

-

... More
Pole lights

46

-

-

... More
Flood light

6

-

-

... More
tree uplighters

25

-

-

... More
Bollards

40

-

-

... More
Post up lights

50

-

-

... More
Wall recessed/ step lights

12

-

-

... More
Pergola lights- downlight

15

-

-

... More
Under water llights

20

-

-

... More
EPABX & FIBRE OPTIC CABLE

-

-

-

... More
Supplying,Laying & Terminating of Jelly filled 0.5/ 0.6mm dia Armoured & PVC Insulated Telecommunication cable of following sizes (Exact Length to be measure at site)

-

-

-

... More
50 Pair

200

-

-

... More
10 Pair

100

-

-

... More
SITC of the following sheet steel clad wall / recess mounting telephone tag block of Krone make constructed from 14 SWG sheet steel, finished with red oxide coating of two coats of paint, with hinged gasketted door and complete with adequately rated and sized telephone terminal block to receive incoming and outgoing wires.

-

-

-

... More
150 pair MDF

1

-

-

... More
Supplying, Installation, Testing & Commissioning of DOT approved EPBAX Exchange with provision of 08nos. P&T Lines, 10 Digital Extensions & 100 analogue extensions with following features complete as required. If some item is missing contractor should consider it too if required for the system to work smoothly.

1

-

-

... More
8 Party Conference

-

-

-

-

-

-

... More
Single Digit numbering for Important Services

-

-

-

... More
Call routing by CLI

-

-

-

... More
Multi call Forwarding

-

-

-

... More
Dial Tone transfer

-

-

-

... More
Built in two external paging ports

-

-

-

... More
Built in Reversal circuit

-

-

-

... More
VOIP Compatible

-

-

-

... More
Automatic route selection / least call routing

-

-

-

... More
Supply, Installation , Testing and commissioning of Telephone handet with 2 line operation, 3 Way Confrenece call, Handsfree, Redial Memory, flash, mute, pause tone & pulse dialing redialing Desk/Wall mountable ringer indicator LED/CLI (with display) complete with connecting cords & jacks as required.

5

-

-

... More
Supply, Installation , Testing and commissioning of Push button Telephone handet with 3 step ringer volume, mute, pause & redial complete with connecting cords & jacks as required.

80

-

-

... More
Supplying,Laying of Multi core Armoured Optical Fibre cable OM3 6 core for building to building connectivity for Telecommunication / Data transfer etc. (Exact Length to be measure at site)

1200

-

-

... More
Supplying and Installation of 6 core loaded LIC complete in all aspects with all the accessories required.

2

-

-

... More
Supplying and Installation of 3 mtr. Fibre Patch Cord LC to LC connectivity complete in all aspects as required.

2

-

-

... More
CIVIL WORKS FOR ELECTRICAL WORKS

-

-

-

... More
Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department

-

-

-

... More
Upto 1.5 Mtr Depth

-

-

-

... More
ESS Room

15

-

-

... More
DG Foundation

7

-

-

... More
Meter Room

7

-

-

... More
Blasting hard and compacted sheet rock excluding sand stone measured in solid including jumping holes cost of explosive fuse, detonator, etc and stacking the blasted debris clear of work within 50m lead.

-

-

-

... More
ESS Room

15

-

-

... More
DG Foundation

7

-

-

... More
Meter Room

7

-

-

... More
Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance, taxes, royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
ESS Room

3

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

1.1

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:4:8) using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
ESS Room

5.5

-

-

... More
DG Foundation

4

-

-

... More
Meter Room

3

-

-

... More
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running Charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-Charge but excluding the cost of steel reinforcement

-

-

-

... More
R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.

-

-

-

... More
ESS Room

8

-

-

... More
DG Foundation

19

-

-

... More
Meter Room

-

-

-

... More
R.C.C. Floor and Roof slab, landing, balconies up to 4.3Mtr. Height.

-

-

-

... More
ESS Room

-

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

3

-

-

... More
Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.)

-

-

-

... More
ESS Room

12

-

-

... More
DG Foundation

27.65

-

-

... More
Meter Room

4.5

-

-

... More
Providing and laying Brick masonry work in Foundation & Plinth using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, all taxes, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
ESS Room

12

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

6

-

-

... More
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, all taxes, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
ESS Room

25

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

8

-

-

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer

-

-

-

... More
Using M.S. angles 40x40x6 mm for diagonal braces

-

-

-

... More
ESS Room

-

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

2.1

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

-

-

-

... More
80x1.25 mm M.S. laths with 1.25 mm thick top cover

-

-

-

... More
ESS Room

21

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

9

-

-

... More
Providing and fixing ball bearing for rolling shutters.

-

-

-

... More
ESS Room

4

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

2

-

-

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- Charge,(area of grill to be measured).

-

-

-

... More
ESS Room

7

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

3

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

-

-

-

... More
ESS Room

25

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

10.5

-

-

... More
Providing 18 mm thick Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
ESS Room

3

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

1.5

-

-

... More
Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
ESS Room

95

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

30

-

-

... More
Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
ESS Room

115

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

33

-

-

... More
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
ESS Room

25

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

11

-

-

... More
Providing and applying 2 coats of Acrylic Distemper of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats,including of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-Charge. (colour & shade to be approved before procurment & use)

-

-

-

... More
ESS Room

120

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

40

-

-

... More
Providing & Painting two or more coats with texture exterior paint of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
ESS Room

115

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

33

-

-

... More
Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Note- colour and shade shall be approved before procurement and use.)

-

-

-

... More
ESS Room

55

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

27

-

-

... More
Supplying fitting, fixing fully glazed aluminum framed openable windows using 15 micron anodized OEL aluminum section 2082 as out section, 9139 as mullion section, 4124 as a shutter section frame with tapered clip of section 4125, aluminum angle , rubber beading, friction stay and handle etc. with 5mm black glass as panel fitted with rubber beading including locking arrangement ,all fittings and the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, hire and running Charges of drilling machine, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
ESS Room

47.26

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

18.9

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with black glass of appropiate thickness, EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-Charge

-

-

-

... More
6 mm thick plain glass

-

-

-

... More
ESS Room

7.5

-

-

... More
DG Foundation

-

-

-

... More
Meter Room

2.5

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
(a) Applying a slurry coat of neat cement using 2.75 kg/Sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.

-

-

-

... More
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-Charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs

-

-

-

... More
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm. of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge.

-

-

-

... More
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep

-

-

-

... More
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

-

-

-

... More
ESS Room

28

-

-

... More
Meter Room

12.1

-

-

... More
INTERNAL PLUMBING WORKS

-

-

-

... More
INTERNAL WATER SUPPLY WORKS

-

-

-

... More
Providing and fixing Clorinated Polyvinyl Chloride (CPVC) pipes SDR-11 conforming to IS: 15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. The includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.

-

-

-

... More
20 mm nominal outer dia Pipes

-

-

-

... More
Institute building

294

-

-

... More
Hostel building

1160

-

-

... More
25 mm nominal outer dia Pipes

-

-

-

... More
Institute building

216

-

-

... More
Hostel building

845

-

-

... More
32 mm nominal outer dia Pipes

-

-

-

... More
Institute building

90

-

-

... More
Hostel building

4

-

-

... More
40 mm nominal outer dia Pipes

-

-

-

... More
Institute building

4

-

-

... More
Cutting grooves in pucca floors and walls for taking GI/PVC Pipes and making good the damanges as per specification & direction of EIC all complete.

-

-

-

... More
Institute building

510

-

-

... More
Hostel building

2005

-

-

... More
Cutting Holes through Existing Brick masonary work including making good the same in Cement Mortar (1:4) for taking GI/PVC pipes & fiitings etc as per specification & direction of EIC all complete.

-

-

-

... More
Institute building

40

-

-

... More
Hostel building

310

-

-

... More
Cutting Holes in RCC floors & roof upto 19 cm thick for Passing GI/PVC Pipes and fiittings etc and repairing the holes after insertion of Pipes etc with Cement Concrete (1:2:4) including Finishing complete so as to make it leak proof' as per specification & direction of EIC all complete.

-

-

-

... More
Institute building

5

-

-

... More
Hostel building

5

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore. MAKE:- JAQUAR-CON-059KN/Equivalent

-

-

-

... More
15 mm nominal bore

-

-

-

... More
Institute building

90

-

-

... More
Hostel building

589

-

-

... More
Providing & fixing full way lever operated forged brass ball valve conforming to IS 1703-1977 of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. MAKE:-ZOLOTO/EQUIVALENT

-

-

-

... More
25 mm dia.

-

-

-

... More
External

14

-

-

... More
32 mm dia.

-

-

-

... More
Institute building

33

-

-

... More
Hostel building

134

-

-

... More
External

4

-

-

... More
40 mm dia.

-

-

-

... More
Institute building

9

-

-

... More
INTERNAL SOIL, WASTE, RAIN WATER AND VENT PIPES

-

-

-

... More
Supplying all materials, labour, T&P and fitting and fixing C.I.(Hubeless)soil waste ventilating pipes and fittings of the following with suitable clamps having provision for removal diameter conforming to ISI No. 15905 to walls with shelded(S/S) coupling with EPMD rubber gasket method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in Charge MAKE:-NEECO/EQUIVALENT.

-

-

-

... More
100 mm dia CI Hubless Pipe.

-

-

-

... More
Institute building

576

-

-

... More
Hostel building

2738

-

-

... More
100 mm plain bend of required degree.

-

-

-

... More
Institute building

36

-

-

... More
Hostel building

23

-

-

... More
100 mm heel rest sanitary bend.

-

-

-

... More
Institute building

18

-

-

... More
Hostel building

193

-

-

... More
100 mm single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.

-

-

-

... More
Institute building

154

-

-

... More
Hostel building

924

-

-

... More
100 mm single equal plain junction of required degree.

-

-

-

... More
Hostel building

20

-

-

... More
100 mm vent Cowl.

-

-

-

... More
Institute building

31

-

-

... More
Hostel building

154

-

-

... More
100 mm SS 304 Coupling.

-

-

-

... More
Institute building

372

-

-

... More
Hostel building

775

-

-

... More
100 mm Floor Clean out Pipe

-

-

-

... More
Institute building

24

-

-

... More
Hostel building

5

-

-

... More
Providing and fixing M.S clamps of approved design to Sand Cast iron/ cast iron (spun) pipe, fixed to wall using 2 nos. 12 mm x 50 mm Dash fasteners including cost of cutting holes and making good the walls etc as directed by Engineer in Charge.

-

-

-

... More
100 mm dia. pipe

-

-

-

... More
Institute building

216

-

-

... More
Hostel building

1072

-

-

... More
Providing and fixing Floor trap of self cleansing design with screwed down or hinged grating with or without vent arm complete,including cost of cutting and making good the walls and floors:(F.T.+U.T.).MAKE:-NEECO

-

-

-

... More
Institute building

44

-

-

... More
Hostel building

182

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC soil, waste water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.MAKE:-AJAY/ASTRAL/EQUIVALENT

-

-

-

... More
50 mm nominal bore

-

-

-

... More
Institute building

113

-

-

... More
Hostel building

449

-

-

... More
Providing & fixing 75mm x 50mm pvc. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to waste pipe.MAKE: ASTRAL/EQUIVALENT

-

-

-

... More
Institute building

36

-

-

... More
Hostel building

128

-

-

... More
Providing and fixing Heavy Class SS grating with of approved design including setting in floor with cement motor to match with floor finish as per architect requirement .MAKE:-FLOOR DRAIN-RSG 102 Anti Scratch/EQUIVALENT

-

-

-

... More
100 mm dia

-

-

-

... More
Institute building

36

-

-

... More
Hostel building

128

-

-

... More
Providing and fixing Heavy Class SS grating with Cockroach proof strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT.MAKE:-FLOOR DRAIN RSB 102 H ATI SCRATCH/ EQUIVALENT.

-

-

-

... More
100 mm dia

-

-

-

... More
Institute building

44

-

-

... More
Hostel building

127

-

-

... More
Providing and fixing pvc Hopper for 100 mm dia floor trap formed out of main pipe with multiple side inlets, suitable for various dia pipes, side connections, including all fixtures and fittings as per site conditions and as per standard details and water tight sealing of joints and area surrounding the grating and as directed by the EIC.MAKE:-ASTRAL M112003344//EQUIVALENT

-

-

-

... More
Institute building

36

-

-

... More
Hostel building

128

-

-

... More
SANITARY FIXTURES & FITTINGS

-

-

-

... More
Supplying all materials, labour, T&P and fixing Extended wall mounted Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in Charge.

-

-

-

... More
HINDWARE CORNICE CAT NO.92055(P-23),CISTERN-92121 STARWHITE/EQUIVALENT

-

-

-

... More
Institute building

2

-

-

... More
HINDWARE MARIO CAT NO. 20084 (P-15), CISTERN-21052/EQUIVALENT

-

-

-

... More
Institute building

23

-

-

... More
Hostel building

111

-

-

... More
Providing and fixing CI Hubless WC connector (Push Fit Type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as per specification and direction of the Engineer in Charge. MAKE:NEECO/EQUIVALENT

-

-

-

... More
Institute building

25

-

-

... More
Hostel building

111

-

-

... More
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete,shanks and back nuts of 15mm dia nominal bore,fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in Charge.

-

-

-

... More
TABLE TOP BASIN-HINDWARE AMAZON CAT NO. 91094 STARWHITE/EQUIVALENT

-

-

-

... More
Institute building

2

-

-

... More
Hostel building

3

-

-

... More
UNDER COUNTER BASIN-HINDWARE ZEN CAT NO. 10049 STARWHITE/EQUIVALENT

-

-

-

... More
Institute building

33

-

-

... More
Hostel building

3

-

-

... More
SEMI RECESSED BASIN-HINDWARE ENIGMA CAT NO. 91012 STARWHITE/EQUIVALENT

-

-

-

... More
Hostel building

107

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink as per Specification. Make-JAQUAR ALD 769L 300 X 190/EQUIVALENT.

-

-

-

... More
Institute building

62

-

-

... More
Hostel building

116

-

-

... More
Providing and fixing stainless steel A ISI 304(18/8) kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in Charge. MAKE:- JAYNA SB 03 ANTI SCRATCH/Equivalent

-

-

-

... More
Institute building

4

-

-

... More
Hostel building

7

-

-

... More
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in Charge.

-

-

-

... More
Single Lever Basin Mixer- JAQUAR ASTRA ATR-3001B/EQUIVALENT

-

-

-

... More
Hostel building

110

-

-

... More
Single Lever wall mounted Basin Mixer & spout with rectangular plate- JAQUAR OPL-15233K,Concelaed Part-ALD 233/EQUIVALENT

-

-

-

... More
Institute building

2

-

-

... More
Hostel building

3

-

-

... More
Pressmatic Pillar Tap- JAQUAR PRS-031L65/EQUIVALENT

-

-

-

... More
Institue building

36

-

-

... More
Hostel building

3

-

-

... More
Health Faucet.-JAQUAR ALD-CHR-565/EQUIVALENT.

-

-

-

... More
Institute building

28

-

-

... More
Hostel building

114

-

-

... More
Short body bib cock-JAQUAR CON-037KN/EQUIVALENT.

-

-

-

... More
Institute building

33

-

-

... More
Hostel building

115

-

-

... More
Shower Diverter & spout-JAQUAR FUS 29065K-Exposed Part,ALD 065-Concelaed Part,SPJ 433-Spout,OHS 1759-Shower,SHA 477-Arm/EQUIVALENT.

-

-

-

... More
Hostel building

110

-

-

... More
Overhead Rain Shower with diverter & Hand Shower with wall oulet & connecting pipe -JAQUAR FUS 29065K-Exposed Part,ALD 605-Concelaed Part,SPJ 433-Spout,OHS 1759-Shower,SHA 477-Arm,JAQUAR HSH-1717-HAND SHOWER,SHA-1195R - WALL OUTLET, SHA-571 - CONNECTING PIPE / EQUIVALENT

-

-

-

... More
Hostel building

3

-

-

... More
Sink Mixer with wall mounted Sprout- JAQUAR CON-309KN/EQUIVALENT

-

-

-

... More
Institute building

1

-

-

... More
Hostel building

6

-

-

... More
Wall mounted Sink Cock.JAQUAR CON-357KN/EQUIVALENT

-

-

-

... More
Institute building

8

-

-

... More
Hostel building

4

-

-

... More
Pressmatic Flush Valve.JAQUAR PRS-073/EQUIVALENT

-

-

-

... More
Institute building

27

-

-

... More
Hostel building

3

-

-

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with flush valve, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. MAKE:-Urinal-HINDWARE DYNA STARWHITE /EQUIVALENT.

-

-

-

... More
Institute building

27

-

-

... More
Hostel building

3

-

-

... More
Providing and fixing in position storage type automatic electric water heater pressure/ non pressure type thermostratically controlled, single phase, vertical wall mounted of approved make (to the approval of Engineer-in-Charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.

-

-

-

... More
6 litre capacity water heater.Make- JAQUAR ELENA/EQUIVALENT

-

-

-

... More
Institute building

4

-

-

... More
Hostel building

113

-

-

... More
Providing and fixing of Physically Handicapped toilet set consisting of (Washbasin 65 x 35 with one pair mounting Brackets,EWC & cistern complete with fittings & seat cover,One no. of hinged rail 76 cm & five Nos. of grab rail 60 cm),including all cost of labour, material, conveyance, loading, unloading, T&P etc. all complete as per the direction of Engineer-in-Charge.(HINDWARE MATRIX-CODE NO.70002/Equivalent)

-

-

-

... More
Institute

3

-

-

... More
Hostel

3

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized CP towel ring complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in Charge.MAKE:- JAQUAR ACN-1151N/EQUIVALENT

-

-

-

... More
Hostel building

107

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized CP towel rack with three hooks complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in Charge.MAKE:-JAQUAR AHS-1581H/EQUIVALENT

-

-

-

... More
Hostel building

107

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized CP towel rail with three hooks complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in Charge.MAKE:-JAQUAR AHS-1507/EQUIVALENT

-

-

-

... More
Institute building

21

-

-

... More
Hostel building

5

-

-

... More
Providing all materials, labour and T&P for fixing of of CP shower Basket Holder.MAKE:JAQUAR ACN-1177N/EQUIVALENT.

-

-

-

... More
Hostel building

110

-

-

... More
Providing all materials, labour and T&P for fixing of of CP soap Dispenser.MAKE:-JAQUAR ACN-ABR-1135N/EQUIVALENT

-

-

-

... More
Institute building

12

-

-

... More
Hostel building

111

-

-

... More
Fixing standard size Chromium plated brass porcelain Toilet paper holder fixed to wooden plugs and chromium Plated brass screws complete as per specification. MAKE:- JAQUAR ACN-CHR-1171N/EQUIVALENT.

-

-

-

... More
Institute building

25

-

-

... More
Hostel building

111

-

-

... More
Providing and fixing CP brass twin coat hooks fixed on toilet door/wall with CP brass screws. Make-JAQUAR-CAN-1161N/EQUIVALENT.

-

-

-

... More
Institute building

4

-

-

... More
Hostel building

107

-

-

... More
Supply, Installation, Testing and commissioning of drinking water cooler cum purifier with built in 3 stage UV based advanced purification process with bottle filler facility having three No. of Faucets (2 Cold Water + 1 Normal Water) made up fo SS 304 grade body, ADA Compliant, size 640mm width X 450mm depth X 1350mm height, flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit Suitable to Freon 22 Refrigerant, Adjustable thermostat control, suitable for 220-230v/50-60 hz A/C Supply Complete with all accessories which include MD-CU29, which is an EPA registered antimicrobial copper that fights off microorganisms which include MRSA and e-coli. The water Fountain shall possess NSF-USA, Green building, energy star saving certification, and to be placed at different location of buidling. Agency has to execute all civil work for installing the Water Fountain for proper functioning and aesthetic view etc all complete as per specification and direction of the Engineer in Charge.

-

-

-

... More
Water cooler Cum Purifier- 120 Ltr Capacity. Make- Eureka Forbes/Voltas/Equivalent

-

-

-

... More
Institute building

4

-

-

... More
Hostel building

4

-

-

... More
INTERNAL FINISHING WORKS

-

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of Toilets , kitchen and other areas as specified by the Engineer in Charge by providing & Applying two coats of elastomeric polymer of 1 mm thickness consisting of a uniformly mixed paste of liquid polymer and cementious powder component, mixed as per manufacturer's specifications after duly cleaning the existing surfaces of all grease, oil, dirt or any other loose items as required.

-

-

-

... More
Institute building

190

-

-

... More
Hostel building

398.3

-

-

... More
Providing & filling sunken floors with good quality cinder well compacted and top surface dressed and levelled to proper gradient as per direction of the Engineer -in-Charge including cost of all labour, cost of sand, royalty, taxes, loading, unloading, transportation, sundries, T&P, etc. complete.

-

-

-

... More
Institute building

38

-

-

... More
Hostel building

79.66

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:2:4) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties,cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

... More
Institute

14.3

-

-

... More
Hostel

29.9

-

-

... More
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading,royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge..

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

67.7

-

-

... More
First Floor

67.7

-

-

... More
Second Floor

59

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

361.9

-

-

... More
First Floor

304.1

-

-

... More
Second Floor

248.9

-

-

... More
Providing Flush pointing in cement mortar (1:3) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

737.1

-

-

... More
First Floor

406.6

-

-

... More
Second Floor

406.6

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

1026.9

-

-

... More
First Floor

741.5

-

-

... More
Second Floor

782

-

-

... More
Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading,royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-Charge.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

115.6

-

-

... More
First Floor

115.6

-

-

... More
Second Floor

115.6

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

187

-

-

... More
First Floor

129.2

-

-

... More
Second Floor

107.1

-

-

... More
Providing and laying Glazed Vitrified Wall Tiles in dado/skirting confirming to IS :15622 of approved make, quality, colour and size 300mm x 600mm,with intermidiate spacers of 4 mm width upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with epoxy grout of approved shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Make: Tiles-Kajaria/Somany/Equivalent. Grout-Kerakoll/Weber/Equivalent (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

737.1

-

-

... More
First Floor

406.6

-

-

... More
Second Floor

406.6

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

1026.9

-

-

... More
First Floor

741.5

-

-

... More
Second Floor

782

-

-

... More
Providing and laying 600 mm x 600 mm Matte finished Vitrified Floor Tiles confirming to IS : 13756 of approved make, quality and colour without any warpage,with intermidiate spacers of 4 mm width laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.Tiles-Kajaria/Somany/Equivalent. Grout-Kerakoll/Weber/Equivalent (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

67.7

-

-

... More
First Floor

87

-

-

... More
Second Floor

59.1

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

361.9

-

-

... More
First Floor

304.1

-

-

... More
Second Floor

248.9

-

-

... More
Making RCC Counter Slab including providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated nominal mix cement concrete of M-20 including the cost of Centering and Shuttering grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running Charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-Charge but excluding the cost of steel reinforcement

-

-

-

... More
Counter Slab

-

-

-

... More
Institute Building

1.4

-

-

... More
Hostel building

13.3

-

-

... More
Providing & laying granite stone slab in counter slabs using 20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm. laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Institute building

19.1

-

-

... More
Hostel building

176.7

-

-

... More
Providing and fixing Urinal Partitions of upto 1200mm x 600mm as per Design made of 12mm thick HPL ( Merinolam/Equivalent of approved Shade ), Edge bended with matching colour, fixed to the back wall using 3 nos. SS Clamps of approved make and sample securly fixed with 2 nos. fasteners Nos. as per direction of Engineer-in-Charge .

-

-

-

... More
Institute building

24

-

-

... More
Hostel building

2

-

-

... More
Supplying all materials, labour, T&P and fixing 6 mm mirror of superior glass conforming to IS:3438-1996,with polished edges, mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in Charge.

-

-

-

... More
Institute building

16.7

-

-

... More
Hostel building

30.2

-

-

... More
Providing and applying 2 coats of Plastic Emulsion Paint of approved quality and shade over a coat of cement based Putty & primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats,including of all materials, labour, conveyance, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-Charge. (colour & shade to be approved before procurment & use)

-

-

-

... More
Institute Building

-

-

-

... More
Ground Floor

183.3

-

-

... More
First Floor

183.3

-

-

... More
Second Floor

174.6

-

-

... More
Hostel Block

-

-

-

... More
Ground Floor

548.9

-

-

... More
First Floor

433.3

-

-

... More
Second Floor

356

-

-

... More
Providing, fitting and fixing of 32mm thick Factory made Single Leaf Rigid FRP (alternately called GRP) Sandwitch composite door shutter of 32 mm thick laminated with two GRP skins with wood grain finish, fabricated using UV-stabilized isopthalic Gelcoat and one layer of 450 gsm E-glass chopped strand mat (CSM) impregnated with orthopthalic polyster resin.The thickness of the skins shall not be less than 3.0mm. Expanded Polysterene Structural (EPS) foam panel of 29mm thickness and a density of 20 Kg/Cum shall be used as core material.

-

-

-

... More
Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinforcements for fixing the metal fittings such as tower bolt, aldrop, handles, etc. shall be provided.A structural adhessive compatible with EPS foam shall be used for bending the core materials,the shall wood reinforcements and the skins.The material and process for manufacturing the door shutter shall confirm to RV-TIFAC composites Design Centre's standards andspecifications & the Door shutter tested in conformation to IS: 4020-1998.The finish of Door shutter will be plain colour/white/ivory/beige/light grey/mahogany/teak wood or any other colour using high quality pigments.Three heavy weight mild steel butt hinges type-I (ISI Marked) size 100 mm are to be fitted on one side of shutter with FRP Frame of size 45 x 90 mm The rate include cost of all materials,shutter,frame, cost of labour, conveyance,loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Institute Building

97.3

-

-

... More
Hostel Block

198.8

-

-

... More
EXTERNAL PLUMBING WORKS

-

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
Supplying all materials, labour, T&P and providing and laying in trenches or Vertical Stacks, galvanized mild steel tubes (medium grade) conforming to IS:1239/2004, part-1 of the following nominal bore and tube fittings including testing & excavating trenches as required & refilling with appropiate materials as per specification and direction of the Engineer in Charge.

-

-

-

... More
25 mm dia nominal bore

-

-

-

... More
External

78

-

-

... More
32 mm dia nominal bore

-

-

-

... More
Institute building

187

-

-

... More
Hostel building

762

-

-

... More
External

362

-

-

... More
40 mm dia nominal bore

-

-

-

... More
Institute building

43

-

-

... More
Hostel building

86

-

-

... More
External

126

-

-

... More
50 mm dia nominal bore

-

-

-

... More
Institute building

19

-

-

... More
Hostel building

440

-

-

... More
External

25

-

-

... More
65 mm dia nominal bore

-

-

-

... More
Hostel building

10

-

-

... More
External

407

-

-

... More
Supplying all materials, labour,T&P and painting two coats with enamel paint of specified colour brushing interior over one coat of priming with red oxide zinc chrome primer on the external surface of new galvanised mild steel tubes and fittings of following nominal diameter to give an even shade including preparing the surface and clearing the surface of all all dirts, dusts and foreign matters as per direction of the Engineer in Charge.

-

-

-

... More
25 mm dia nominal bore

-

-

-

... More
External

78

-

-

... More
32 mm dia nominal bore

-

-

-

... More
Institute building

187

-

-

... More
Hostel building

762

-

-

... More
External

362

-

-

... More
40 mm dia nominal bore

-

-

-

... More
Institute building

43

-

-

... More
Hostel building

86

-

-

... More
External

126

-

-

... More
50 mm dia nominal bore

-

-

-

... More
Institute building

19

-

-

... More
Hostel building

440

-

-

... More
External

25

-

-

... More
65 mm dia nominal bore

-

-

-

... More
Hostel building

10

-

-

... More
External

407

-

-

... More
Providing and fixing of Brass or Gun Metal Full Way Valve conforming to IS: 781:1995 of the Following nominal Sizes with wheel as per specification complete as per direction of Engineer-in-Charge.MAKE:-ZOLOTO/EQUIVALENT

-

-

-

... More
50 mm dia.

-

-

-

... More
Institute building

2

-

-

... More
Hostel building

8

-

-

... More
External

14

-

-

... More
65 mm dia.

-

-

-

... More
Institute building

2

-

-

... More
Hostel building

2

-

-

... More
External

6

-

-

... More
Providing & fixing of gun metal Check or non return valve Class-I conforming to IS : 5312 (Part I) 2004 of the following bore as per the Specification & Direction of Engineer in Charge Complete.

-

-

-

... More
50 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Providing and fixing resilient rubber neoprene lined arch vibration eliminators with unit control nuts, bolts, washers, companion flange as per table E complete suitable for working pressure of 15 Kg/sqcm.

-

-

-

... More
50 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Providing and fixing dial type pressure gauge with isolation cock and chrome plated copper pipe, Diameter 150 mm calibration 0-16Kg/cm sq.

2

-

-

... More
Providing & fixing C.I. 'Y' Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required (on pump suction).

-

-

-

... More
50 mm dia

2

-

-

... More
Constructing masonry Chamber for sluice valve of size 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) ,100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.

-

-

-

... More
With F.P.S. bricks

2

-

-

... More
Constructing masonry Chamber for sluice valve, with C.I. surface box 30 x 30 x 50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.

-

-

-

... More
With F.P.S. bricks

30

-

-

... More
EXTRENAL SEWERAGE AND DRAINAGE

-

-

-

... More
Providing and laying non-pressure NP3 class (Medium duty) R.C.C. pipes with Spigot Joint with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) in trenches including excavation of trenches,bedding with cement concrete 1:5:10 & making haunches all around the pipe with cement concrete 1:2:4, refilling the trenches after laying the pipe with excavated earth/sand & testing of joints etc.all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
150 mm dia R.C.C pipe

447

-

-

... More
200 mm dia R.C.C pipe

412

-

-

... More
300 mm dia R.C.C pipe

921.5

-

-

... More
600 mm dia R.C.C pipe

921.5

-

-

... More
Constructing manholes with R.C.C top slab in (1:2:4) mix, foundation concrete (1:4:8), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including approved type RCPC manhole cover all complete as per specification & Direction of EIC.

-

-

-

... More
Inside size 90 x 80 cm and 90 cm deep

-

-

-

... More
With F.P.S. bricks with class designation 75

-

-

-

... More
Sewerage

39

-

-

... More
Storm Water

37

-

-

... More
Extra for every Additional Depth of 0.10 Meter or Part thereof of Mahole

-

-

-

... More
450 mm to 900 mm Depth

-

-

-

... More
Sewerage

23.4

-

-

... More
Storm Water

22.2

-

-

... More
Supplying all materials, labour, T&P for construction of circular type manholes with approved RCPC manhole cover and ring, bottom slab & shaft made of Reinforced cement concrete 1:1.5:3 (M20) below 1.5m upto required depth with graded granite stone aggregate (12mm nominal size), foundation concrete(1:4:8) using graded HG stone aggregate 40mm nominal size, brick masonry using Ist class Fly Ash bricks (25cm x 12cm x 8cm) having crusing strength not less than 75 kg/cm2 in cement mortar (1:5) , inside plastering 12mm thick (1:3) finished smooth with neat cement punning, outside plaster (1:3) and making benching with cement concrete 1:2:4 (M15) using graded granite stone aggregate 12mm nominal size, making smooth to the surface of benching and channel, testing & commissioning, lighting, watch & ward etc., all complete as per approved design & drawing & direction of Engineer in Charge. (Excluding earth work)

-

-

-

... More
1200mm internal diameter x 2000mm depth with sides sloped upto 560mm internal diameter at top

-

-

-

... More
Sewerage

30

-

-

... More
Storm Water

5

-

-

... More
Extra for every Additional Depth of 0.10 Meter or Part thereof above 1670 mm to 2300 mm depth in circular Manhole 1200 mm diameter.

-

-

-

... More
Every Additional Depth of 0.10 Meter

-

-

-

... More
Sewerage

18

-

-

... More
Storm Water

3

-

-

... More
Constructing brick masonry road gully chamber/catch basin 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) as per directions of Engineer-in-Charge

-

-

-

... More
With F.P.S. bricks

-

-

-

... More
External

254

-

-

... More
PUMPS & EQUIPMENT

-

-

-

... More
Supply, assembly, erection, testing and commissioning of SS submersible non-clog clear water pumps, suitable to handle to lift water from UG tank to OH tanks having the following capacities with vortex impeller / grinder type, complete with 3 phase squirrel cage submersible motor of required HP for 415 ± 10% volts, 3 phase, 50 Hz. A.C. supply cooled by surrounding liquid, submersible cable upto main panel within the plant room, dry running prevent or, G.I. guide pulling chain, all the necessary piping and accessories, valves, delivery header etc. as required complete in all respects. The rate will include electrical panel & DOL starter of pump manufacturer standard & with level controller and dry running protection giving a disCharge as specified below including required length cable as required including the supply and fixing electrical panel board, 3 phase indicating lamps, incoming and out going switches suitable size wiring, earthing etc. as per electricity rules, the pump shall have provision for sequence operation and to operate both the pumps together)

-

-

-

... More
The above installation shall be complete with sump pump lifting assembly, ready made electro – galvanized MS lifting chain, GI pipe header complete with disCharge manifold, flanges, tee, elbow etc. complete including GI pipe upto the top of sump and including GI union. Header shall be sized for both pump working under delivery velocity of 1.5 m/sec.

-

-

-

... More
With Additional Accessories like Common disCharge header assembly of 50 mm dia with pressure switch & Pressure gauge, with 200 LTR Pressure tank, along with Fixed speed Automation control panel with DOL starter for the system with MODBUS connectivity for the connectivity with the BMS System along with Level sensor for dry run protection of the pump

-

-

-

... More
With Supply and Installation of Differential Float Valve of 50mm size for Overhead Tank for starting and stopping the pump as required in Nos. of the the fushing/doemstic use Overhead tank.

-

-

-

... More
Flushing: Capacity : 80 LPM Nos. Pump (1 Working + 1 Standby) @ 50 M head.

1

-

-

... More
Domestic: Capacity : 100 LPM Nos. Pump (1 Working + 1 Standby) @50 M head.

1

-

-

-

-

-

... More
Design, supplying, installing, testing & commissioning of Sewage Treatment Plant (including MS/Civil construction work) for the following duty:

-

-

-

... More
ELCTROMECHANICAL ITEMS

-

-

-

... More
Design, construction, testing & comimissioning of Sewage Treatment Plant (STP) of capacity 50 KLD with MBBR technology with Bar Screen,Level Sensors, MS Aeration Tank with(Paint), Diffuser(Tube Type), Blower( Twin Lobe Design),Secondary Clarifier Plates,Feed Pumps for tertiary treatment,MGF,ACF,Butterfly valves,Pressure gauge etc all complete as per PH Specification & direction of EIC.

1

-

-

... More
CIVIL ITEMS

-

-

-

... More
Supply of all material,labour & T&P for Civil works in RCC M-25 with excavation of earth work for Raft,Equalisation Tank,Treated water Tank,sludge holding tank,clarified water tank & drain pit etc all complete as per the direction of EIC for 50 KLD STP.

1

-

-

... More
Out of 100% of Total Cost payment Schedule

-

-

-

... More
Approval of Design & drawing

2

-

-

... More
Site Clearance & Devlopment of Site

2

-

-

... More
Excavation of Foundation & drain pit

2

-

-

... More
Execution of work i.e Sand filling, PCC (1:4:8),Raft & drain Pit with RCC M-25.

20

-

-

... More
Construction of RCC M-25 Equalisation Tank, oil & Grease Tank,Grit Tank,Clarified Water Tank & Treated Water Tank as per approved drawings.

15

-

-

... More
Supply of Mechnical Equipments i.e Bar Screen,Level Sensors, MS Aeration Tank with(Paint), Diffuser(Tube Type), Blower( Twin Lobe Design),Secondary Clarifier Plates,Feed Pumps for tertiary treatment,MGF,ACF,Butterfly valves,Pressure gauge etc.

38

-

-

... More
Erection & Installation of all Mechanical Components.

13

-

-

... More
Testing & Commissioning .

5

-

-

... More
Maintainence for 1 Year from the date of Commissioning.

3

-

-

... More
CIVIL WORKS FOR PH WORKS

-

-

-

... More
Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department.

-

-

-

... More
Upto 1.5 Mtr Depth

-

-

-

132

-

-

... More
Retention Pond

21

-

-

... More
1.5 Mtr To 3.0 M Depth

-

-

-

61.6

-

-

... More
Retention Pond

11.2

-

-

... More
Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered.

-

-

-

193.6

-

-

... More
Retention Pond

32.2

-

-

... More
Filling the Foundation and Plinth, sides of foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, taxes, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

64.55

-

-

... More
Retention Pond

10.75

-

-

... More
Supplying and filling with sand in foundation and plinth in layers not exceeding 20 cm in depth, well watered and compacted , top surface dressed and levelled to proper level and gradient including cost of all materials, conveyance,royalties, loading, unloading, cost of all labour, T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

26.4

-

-

... More
Retention Pond

4.2

-

-

... More
Providing and lying Plain Cement Concrete of proportion (1:4:8) using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, taxes, cost of labours, T&P, hire & running Charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -Charge.

-

-

-

26.4

-

-

... More
Retention Pond

4.2

-

-

... More
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running Charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-Charge but excluding the cost of steel reinforcement

-

-

-

... More
R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc.

-

-

-

93.4

-

-

... More
Retention Pond

8.4

-

-

... More
R.C.C. Floor and Roof slab, landing, balconies up to 4.3Mtr. Height.

-

-

-

30.4

-

-

-

-

-

... More
Institute Building

5.5

-

-

... More
Hostel building

4.5

-

-

... More
R.C.C. Walls & Fins

-

-

-

75

-

-

... More
Retention Pond

80

-

-

-

-

-

... More
Institute Building

8

-

-

... More
Hostel building

9.9

-

-

... More
R.C.C. Beams & Columns

-

-

-

-

-

-

... More
Institute Building

2.4

-

-

... More
Hostel building

2.1

-

-

... More
Providing & fixing TMT Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment.)

-

-

-

298.2

-

-

... More
Retaining Wall

132.6

-

-

-

-

-

... More
Institute Building

22.3

-

-

... More
Hostel building

23.6

-

-

... More
Providing and laying Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 13753 of approved make, quality, colour and size 300mm x 200mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.

-

-

-

975.9

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality

-

-

-

... More
Circular shape 560 mm internal dia

-

-

-

10

-

-

... More
Rainwater Harvesting

-

-

-

... More
Labour for Drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial starta by mud rotary drilling as required to suit the site condition as per the direction of the Engineer in Charge including use of own rigs with its acessories ,tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC Pipes for housing ,fitted with socket and with or without well scren as per the necessity for the soft,medium,hard and boulder formation (GI/PVC PIPES CASING PIPES if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200mm to 450mm dia in over burden portion.

-

-

-

... More
300 mm dia

-

-

-

... More
Retention Pond

180

-

-

... More
Lowering the following size GI/PVC Pipe with or without slotted pipes as per the neccessity from ground level and fitted and fixed up in perfectly vertical position ,including cutting and threading pipe and slotted pipe and supplying and fixing all jointing materials,tools and plants etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above.

-

-

-

... More
200 mm nominal size dia

-

-

-

... More
Retention Pond

180

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the reCharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-Charge.

-

-

-

... More
Retention Pond

4.2

-

-

... More
Supplying all labour, T&P and materials for packing the bore with washed gravel (size P-6) Around the pipe in good quality excluding the cost of gravel etc. complete as per direction of the Engineer in Charge.

-

-

-

... More
Retention Pond

4.2

-

-

... More
BRICK WORK

-

-

-

... More
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, all taxes, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge.

-

-

-

... More
Pump Room over UGT

7.6

-

-

... More
Providing & Painting two or more coats with texture exterior paint of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Pump Room over UGT

30.3

-

-

-

-

-

... More
Institute Building

32.2

-

-

... More
Hostel building

39.6

-

-

... More
Supplying, fitting and fixing of stainless steel of 304 grade ladders per approved design and specification, including buffing, polishing etc with cost, conveyance, taxes of all materials, labour T&P etc. required for the complete in all respect as per the direction of Engineer -in- Charge.

-

-

-

51.4

-

-

... More
Institute

51.4

-

-

... More
Hostel

73.8

-

-

230.8

-

-

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge by applying two coats of elastomeric polymer of 1 mm thickness.The material should consists of a liquid polymer component and a cementious powder component,which shall be mixed as per manufacturer's instuctions and applied over prepared concrete specified by the manufacturer.The surfaces shall be prewetted and two coats of the above mentioned polymer to be applied. Second coat to be applied in the perpendicular direction of the first coat. It is to be cured for 3 days and Coving the junctions of the retaining wall and base raft with fillet of size 75mm x 75mm with CM 1: 3 admixed with approved compound including finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and mark and cleaning and removing dusts and dirts to ensure surfaces which are to receive the coating must be free from oil, grease, wax, dirt or any other form of foreign matter that might affect adhesion as required.

-

-

-

173.3

-

-

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface as directed by Engineer-in-Charge by applying two coats of elastomeric polymer of 1 mm thickness.The material should consists of a liquid polymer component and a cementious powder component,which shall be mixed as per manufacturer's instuctions and applied over prepared concrete specified by the manufacturer.The surfaces shall be prewetted and two coats of the above mentioned polymer to be applied. Second coat to be applied in the perpendicular direction of the first coat. It is to be cured for 3 days and Coving the junctions of the retaining wall and base raft with fillet of size 75mm x 75mm with CM 1: 3 admixed with approved compound including finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and mark and cleaning and removing dusts and dirts to ensure surfaces which are to receive the coating must be free from oil, grease, wax, dirt or any other form of foreign matter that might affect adhesion as required.

-

-

-

249.9

-

-

... More
HVAC WORKS

-

-

-

... More
INSTITUTE BUILDING-HVAC

-

-

-

... More
VARIABLE REFRIGERANT FLOW (VRF) SYSTEM.

-

-

-

... More
The prices including all duties or local taxes on all equipments are to be quoted in the below mentioned form & shall include the supply, installation,testing & commissioning at site of all the equipments, ancillary materials as specified and all such items what so ever required to fulfill the intent and purpose as laid down in the specifications and / or drawings .

-

-

-

... More
Imported Variable Refrigerant Flow Air-conditioning System

-

-

-

... More
Supply, Installation, testing & commissioning of Variable Refrigerant Flow modular type airconditioning system Inverter Controlled with stepless modulation complete with indoor & outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping , full Charge of refrigerant gas & oil, control cabling etc. as per detail given in specifications and having following items: (The prices to be given in Indian rupees on Full Import duty basis) Refrigerant to be used shall be - R - 410 A.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Modular type Outdoor unit equipped with highly efficient scroll compressors with one inverter & other constant speed type compressors special heat exchanger, low noise condenser fan , auto check function for connection error, auto address setting with double coat MS base frame (as per reccomendation from manufacturar) with sandwitch type vibration isolator rubber pads and capacity as mentioned below.

-

-

-

... More
For Ground Floor :-

-

-

-

... More
42 HP Heat Pump Type (Cooling Only )

2

-

-

... More
For First Floor :-

-

-

-

... More
48 HP Heat Pump Type (Cooling Only )

2

-

-

... More
For Second Floor :-

-

-

-

... More
28 HP Heat Pump Type (Cooling Only )

2

-

-

... More
Supply, Installation, Testing and Commissioning of Indoor units WITH self diagnostic type remote controllers Corded Type address setting and capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain pump, drain water lift-up mechanism, insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings

-

-

-

... More
Ceiling Mounted Duct Type Indoor AC Units:

-

-

-

... More
Ceiling Mounted Ductable Unit : 4.1 TR / 1600 CFM

3

-

-

... More
Ceiling Mounted Ductable Unit : 6.6 TR / 2740 CFM

5

-

-

... More
4-Way Ceiling Mounted Cassette Units:

-

-

-

... More
Ceiling Mounted Cassette Unit : 0.8 TR / 460 CFM

12

-

-

... More
Ceiling Mounted Cassette Unit : 1.2 TR / 530 CFM

7

-

-

... More
Ceiling Mounted Cassette Unit : 1.6 TR / 565 CFM

25

-

-

... More
Ceiling Mounted Cassette Unit : 2.0 TR / 705 CFM

24

-

-

... More
Ceiling Mounted Cassette Unit : 2.5 TR / 915 CFM

18

-

-

... More
Ceiling Mounted Cassette Unit : 3.3 TR / 1130 CFM

4

-

-

... More
4-Way Ceiling Mounted Cassette Units (Compact Type):

-

-

-

... More
Ceiling Mounted Cassette Unit : 0.8 TR / 350 CFM

10

-

-

... More
2-Way Ceiling Mounted Cassette Units:

-

-

-

... More
Ceiling Mounted Cassette Unit : 1.2 TR / 405 CFM

1

-

-

... More
Ceiling Mounted Cassette Unit : 2.0 TR / 650 CFM

1

-

-

... More
Ceiling Mounted Cassette Unit : 2.3 TR / 740 CFM

1

-

-

... More
Wall Mounted Type Indoor AC Units:

-

-

-

... More
Wall Mounted Type Unit : 3.3 TR / 780 CFM

1

-

-

... More
Note: All above Indoor AC units should have Drain Pump.

-

-

-

... More
Supply, First Full Charging, Testing and Commissioning of R410a refrigerant gas for all units complete

1

-

-

... More
Supply,Installation,Testing and Commissioning of Main Central Remote controller system with LCD panel with adaptor suitable for above indoor units to operate, monitor, on/off, temperature setting etc.

1

-

-

... More
Energy Recovery Ventilators For Fresh air :

-

-

-

... More
Supply, installation, testing & commissioning of ceiling hunged Energy Recovery Ventilator Units (ERV or HRV units) with Air to Air Heat Exchanger, preinstalled Filters, suitable Corded type Remote Controller & of following capacity as per approved shop drawings.

-

-

-

... More
1000 CMH / 588 CFM

1

-

-

... More
1500 CMH / 882 CFM

6

-

-

... More
Hi-Wall Split AC Unit (For Patch Panel Room, IT Hub & Server Room) (For Stand By Purpose)

-

-

-

... More
Supply, installation & testing Commissioning of Inverter Type Hi wall split air-conditioning unit (Cooling Only) consisting of condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 5 RMT. Cost includes M.S. Stand, Gas Charging & Internal Copper Wiring & Remote Control, power wiring, stablizer alongwith Nos. unit (set of indoor & outdoor unit)and drain piping duly insulated with 6 mm thick nitrile rubber etc for below mentioned capacity

-

-

-

... More
1.5 TR. Capacity

4

-

-

... More
2.0 TR. Capacity

2

-

-

... More
Toilet Exhaust Air Fan

-

-

-

... More
Supply, installation, testing and commissioning of Cabinet type Rectangular Inline fans with motor complete motor complete with TEFC Sq. Cage Induction motor suitable for 220 volts ± 10%, 50Hz ± 3 %, single phase A.C supply of class "F" insulation with , mountings accessories in all respect with wiring upto power supply point & of following capacities as per specification and tender drawing mentioned.

-

-

-

... More
595 CMH / 350 CFM

3

-

-

... More
680 CMH / 400 CFM

3

-

-

... More
850 CMH / 500 CFM

3

-

-

... More
Propeller Fans (Small Toilets, Pantry, Store Rooms, Electrical Panel Room Ventilation) :-

-

-

-

... More
Supply, installation, testing and commissioning of propeller fans complete with bird screen rain guard louvers, motor complete with TEFC Sq. Cage Induction motor suitable for 220 volts ± 10%, 50Hz ± 3 %, single phase A.C supply of class "F" insulation with , mountings accessories in all respect with wiring upto power supply point, all complete as required of following capacities as per tender drawing mentioned.

-

-

-

... More
281 CMH / 165 CFM

14

-

-

... More
For Kitchen Air Cooling :

-

-

-

... More
Supply, installation, testing & commissioning of factory fabricated Double Skinned Air-Washer comprising of One Number DIDW GI Fan, Forward curved, complete with base frame,casing made out of 22G galvanised sheet having flanged & bolted panels insulated with 25 mm thick injected fire retardent 40 Kg/m³ density PU foam , wet section & tank shall be made of stainless steel with recessed control starter panel. The Air-washer shall be complete with fill of depth 200mm & face velocity across the fill shall be limited to 152 MPM. The complete Air-washer shall be as specified in the tender document & Schedule of Equipments section.The Air-washer shall have an efficiency of 90% & shall be complete with motor, belt drive package, GI B Class interconnecting piping Aluminum viscous filters etc. & of the following capacities.The airwasher shall be complete with 02 Nos. water circulation pumps including one no. stand by pump as per approved tender drawings..

-

-

-

... More
Air Qty. = 9350 CMH / 5500 CFM

-

-

-

... More
Static Pressure = 50 mm Wg

-

-

-

... More
Fan Speed = Not exceed 1440 rpm

-

-

-

... More
Motor = Not exceed 3.7 Kw.

-

-

-

... More
Fan Dia = 800mm (Approx.)

-

-

-

... More
Pumps(1W+1S) = Not exceed 0.25 HP

1

-

-

... More
For Kitchen Exhaust :

-

-

-

... More
Installation, testing & commissioning of factory fabricated Air-Scrubber comprising of One Number DIDW GI fan, forward curved, complete with base frame, casing made out of 22G galvanised sheet having flanged and bolted panels insulated with TF quality expanded polystyrene, wet section & tank shall be made of stainless steel. The Air-Scrubber shall be complete with fill of depth 200 mm & face velocity across the fill shall be limited to 152 MPM. The complete Air-Scruber shall be as specified in the tender document & Schedule of Equipments section. The Air - scrubber shall have an efficiency of 90% & shall be complete with motor,belt drive package, GI B Class interconnecting piping Aluminum viscous filters etc. & of the following capacities.The air-scrubber shall be complete with 02 Nos.water circulation pumps including 01no.stand by pump.

-

-

-

... More
Air Qty. = 10200 CMH / 6000 CFM

-

-

-

... More
Static Pressure = 50 mm Wg

-

-

-

... More
Fan Speed = Not exceed 1440 rpm

-

-

-

... More
Motor = Not exceed 5.0 Kw.

-

-

-

... More
Fan Dia = 800mm (Approx.)

-

-

-

... More
Pumps(1W+1S) = Not exceed 0.25 HP

1

-

-

... More
PIPING

-

-

-

... More
Refrigerant Piping

-

-

-

... More
Supply & fixing of interconnecting copper refrigerant pipe work (19mm / 13mm thick )duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. All piping inside the room shall be properly supported on MS Slotted trays and all external piping shall run in covered slotted tray.

-

-

-

... More
6.4 mm O.D. (insulation – 13 mm thick)

92

-

-

... More
9.5 mm O.D. (insulation – 13 mm thick)

394

-

-

... More
12.7 mm O.D. (insulation – 13 mm thick)

153

-

-

... More
15.9 mm O.D. (insulation – 19 mm thick)

370

-

-

... More
19.1 mm O.D. (insulation – 19 mm thick)

250

-

-

... More
22.2 mm O.D. (insulation – 19 mm thick)

40

-

-

... More
25.4 mm O.D. (insulation – 19 mm thick)

58

-

-

... More
28.6 mm O.D. (insulation – 19 mm thick)

92

-

-

... More
31.8 mm O.D. (insulation – 19 mm thick)

34

-

-

... More
38.1 mm O.D. (insulation - 19 mm thick)

96

-

-

... More
Supply,Installation,Testing and Commissioning of Y-joints.

106

-

-

... More
Drain Piping

-

-

-

... More
Providing and fixing of UPVC drain water piping complete with fittings, support as per specification and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation.

-

-

-

... More
50 mm dia O.D

91

-

-

... More
40 mm dia O.D

96

-

-

... More
32 mm dia O.D

261

-

-

... More
25 mm dia O.D

287

-

-

... More
DUCTING, GRILLES AND INSULATION

-

-

-

... More
Rectangular / Square Ducting ( Site fabrication )

-

-

-

... More
Supply, fabrication, installation, testing and commissioning of G.S.S. sheet metal ducting & as per ISI specifications & tender drawings. The price shall include with supports such as full threaded rod & GI slotted channel including nut bolt fastner or MS angle & MS rod including nut bolt fastner, sealent (neoprene gasket), access door etc.

-

-

-

... More
24 G (0.63mm)

1030

-

-

... More
22 G (0.80mm)

70

-

-

... More
Supply, installation, testing & commissioning of Pre insulated Aluminium flexible duct, worm clips, supports as follows

-

-

-

... More
100 mm dia

65

-

-

... More
Supply, installation, testing & commissioning of Powder coated Aluminium extruded grilles for supply air normal flow, 15° deflection one way as per specification & the sizes will be as per tender drawing mention:

3

-

-

... More
Supply, installation, testing & commissioning of Powder coated Aluminium extruded Multicone ceiling square diffusers 4 way deflection with anti smudge ring ( removal core type ) for supply / return air required as per the tender drawings.

11

-

-

... More
Supply, installation, testing and commissioning of Aluminium extruded volume control dampers with key operated of anodised black painted matt finished in supply air grills / diffusers.

10

-

-

... More
Supply, installation, testing & commissioning of 16 G GSS constructed opposed blade volume control dampers complete with brass bush & manual operating handles within ducts to be provided with suitable links, levers and quadrants for control of volume of air flow for proper air balancing

1

-

-

... More
Supply, installation, testing and commissioning of 18 G thick Aluminium extruded powder coated weather protected louvers with bird screen type (with Aluminium frames if required) for Intake Fresh air with 12G GI wire mesh as per specification and sizes will be as per tender drawing mentioned.

2

-

-

... More
INSULATION WORKS

-

-

-

... More
Supplying , installation, testing & commissioning of external thermal insulation on ducts with Closed Cell Cross Linked Polythylene (XLPE) Foam of density 33 Kg/m³ with 25 mm thick & thermal Conductivy not exceding 0.035 W/mK at an average Temperature of 40°C. The Material Shall be rated as Class 1, As per BS476 Part 7 , The Smoke Density as per AS - 1530.3 Shall not exceed 1. The Material shall have Fire Approval from CBRI - Roorkie & no toxicity under flaming and non- flaming condition as per AITM 3.000 (1993) .Adhesive used for setting the insulation shall be non - flammable,Vapour Proof. All Joints should be sealed with 3 mm thick 50 mm wide PE tape and Flange to be overlapped by 6" width of the same material thickness. Finally Duct insulated should be strapped by 12mm Plastic Packing strip at every random meter & conforming to standard Spec.

-

-

-

... More
12 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory Aluminium sheet Laminated for Supply air Duct

550

-

-

... More
6 mm thick Closed Cell Cross Linked Polythylene( XLPE) Foam with Factory Aluminium sheet Laminated for ERV Unit's Fresh & Exhaust air Duct

375

-

-

... More
Supply,Installation,Testing and Commissioning of Acoustic lining inside ducts using Non Fibrous fire retardant crosslinked polyethylene foam of 30+/- 3 Kg/m3 density & thickness of 12mm having porous surface on one side & a flat surface on other side using Synthetic rubber based Adhesive preferably Low VOC & high strength characteristic(Initial portion of ducting and main plenum) as per specifications

35

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
PANEL BOARDS

-

-

-

... More
VRF OUTDOOR'S SWITCH BOARD (L.H.S. WING)

-

-

-

... More
Note: For 01 x 28 HP, 01 x 42 HP & 01 x 46 HP outdoor units

-

-

-

... More
Installation, testing and commissioning of Cubical wall mounted type switch board made of 2mm thick CRCA sheet as detailed below & conforming to the specifications.

-

-

-

... More
INCOMER

-

-

-

... More
400 A TPN MCCB with (0–500 A) ammeter, with 3 CT & selector switch, (0-500 V) Voltmeter with selector switch, phase indication light with protection fuse. with protection fuse, on / off / trip indicating light with protection fuse.MCCB Shall be 35 KA ( Icu=Ics)

-

-

-

... More
OUTGOING

-

-

-

... More
For 01 x 28 HP Out door Unit

-

-

-

... More
01 x 63 A TP MCCB & 01 x 40 A MCCB, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, MCCB Shall be 25 KA (Icu=Ics) SET 01

-

-

-

... More
For 01 x 42 HP Out door Unit

-

-

-

... More
02 x 63 A TP MCCB & 01 x 40 A MCCB, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, MCCB Shall be 25 KA (Icu=Ics) SET 01

-

-

-

... More
For 01 x 46 HP Out door Unit

-

-

-

... More
03 x 63 A TP MCCB, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, MCCB Shall be 25 KA (Icu=Ics) SET 01

1

-

-

... More
VRF OUTDOOR'S SWITCH BOARD (R.H.S. WING)

-

-

-

... More
Note: For 01 x 28 HP, 01 x 42 HP & 01 x 46 HP outdoor units

-

-

-

... More
Installation, testing and commissioning of Cubical wall mounted type switch board made of 2mm thick CRCA sheet as detailed below & conforming to the specifications.

-

-

-

... More
INCOMER

-

-

-

... More
400 A TPN MCCB with (0–500 A) ammeter, with 3 CT & selector switch, (0-500 V) Voltmeter with selector switch, phase indication light with protection fuse. with protection fuse, on / off / trip indicating light with protection fuse.MCCB Shall be 35 KA ( Icu=Ics)

-

-

-

... More
OUTGOING

-

-

-

... More
For 01 x 28 HP Out door Unit

-

-

-

... More
01 x 63 A TP MCCB & 01 x 40 A MCCB, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, MCCB Shall be 25 KA (Icu=Ics) SET 01

-

-

-

... More
For 01 x 42 HP Out door Unit

-

-

-

... More
02 x 63 A TP MCCB & 01 x 40 A MCCB, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, MCCB Shall be 25 KA (Icu=Ics) SET 01

-

-

-

... More
For 01 x 46 HP Out door Unit

-

-

-

... More
03 x 63 A TP MCCB, ammeter (0-100A) with three CT, on / off / trip indication lights with protection fuse, MCCB Shall be 25 KA (Icu=Ics)

1

-

-

... More
PANEL FOR KITCHEN AIR WASHER & AIR SCRUBBER :

-

-

-

... More
Supply, installation, testing and commissioning of Cubical type sectionalised/campartmentalised floor/wall standing switchboard by CPRI approved firms complete with 3.5 strip, suitable capacity alumunium bus-bar electrolytic grade E-91, cable alley, switchgears suitable for AC-23 duty & of following capacity as per specification given in the tender

-

-

-

... More
For Fan Motor & Pump Motor

-

-

-

... More
(1 x 5.0 HP Airwasher Fan Motor, 1 x 0.5 HP Pump, 1 x 7.5 HP Airscrubber Fan Motor, 1 x 0.5 HP Pump )

-

-

-

... More
INCOMER

-

-

-

... More
63 A FP MCB with (0 - 63A) ammeter with three CT and selector switch, (0 - 100 V) voltmeter with selector switch, phase indication light with protection fuse.

-

-

-

... More
OUTGOING

-

-

-

... More
For Airwasher Fan Motor 5.0 HP x 01 No.

-

-

-

... More
16A FP MCB with 12 A DOL starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection fuses, Current sensing Single Phase Preventor, auto manual selector switch. MCB shall be of 10KA

-

-

-

... More
For Airwasher's Pump Motor 0.5 HP x 01 No.

-

-

-

... More
06 A FP MCB with 9 A DOL starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection fuses, Current sensing Single Phase Preventor, auto manual selector switch. MCB shall be of 10KA

-

-

-

... More
For Airscrubber Fan Motor 7.5 HP x 01 No.

-

-

-

... More
25A FP MCB with 12 A DOL starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection fuses, Current sensing Single Phase Preventor, auto manual selector switch. MCB shall be of 10KA .

-

-

-

... More
For Airscrubber's Pump Motor 0.5 HP x 01 No.

-

-

-

... More
06 A FP MCB with 9 A DOL starter, overload relay, start / stop push buttons, on / off / trip indication lights with protection fuses, Current sensing Single Phase Preventor, auto manual selector switch. MCB shall be of 10KA

1

-

-

... More
Supply Installation Testing & Commissioning of 06 AMP Isolator switch board with SPN MCB , start / stop push buttons for all Indoor units & Inline fans.

108

-

-

... More
Supply Installation Testing & Commissioning of 16 AMP Isolator switch board with TPN MCB , start / stop push buttons for all Ductable, ERV Units.

16

-

-

... More
POWER & CONTROL CABLING

-

-

-

... More
Supply and laying ,testing & commissioning of following sizes of Copper conductor power cables including earthing with tray including fixing clamps & effecting proper termination to equipment etc.complete as required.

-

-

-

... More
For Outdoor unit

-

-

-

... More
4C x 10 Sq. mm ( Armoured )

130

-

-

... More
4C x 16 Sq. mm ( Armoured )

10

-

-

... More
For Indoor AC unit / Inline fans etc.

-

-

-

... More
3C x 2.5 Sq. mm ( Uuarmoured - Sheathed & Flexible type )

550

-

-

... More
Supply & fixing of control cum transmission wiring of Copper conductor shielded cable alongwith conduite for looping between indoor & outdoor VRF system & to main Central remote controller system

-

-

-

... More
2 C X 1.5 Sq. mm

750

-

-

... More
Note: Single phase power supply 5.0 meter near about all the indoor units / Inline fans / Axial propeller fans etc. by the client.

-

-

-

... More
Supply & laying of 6 SWG GI wire. or in recess for loop earthing as required.

110

-

-

... More
Cable Tray

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
150 mm x 50 mm x 1.6 mm

15

-

-

... More
450 mm x 50 mm x 1.6 mm

20

-

-

... More
HOSTEL BUILDING-HVAC

-

-

-

... More
Split Units Supply

-

-

-

... More
Supply of Air-cooled Split type airconditioners (5-Star Rating) Nos. comprising Rotary compressor, Air-cooled condenser, Condenser Fan etc, with wireless remote.

-

-

-

... More
3.0 TR - Cassette Type

9

-

-

... More
2.0 TR - Hi wall split Type

113

-

-

... More
Installation of Split Units

-

-

-

... More
Installation of Air-cooled Carrier make HI-WALL type airconditioners (5-Star Rating) Nos. comprising Rotary compressor, Air-cooled condenser, Condenser Fan etc.

-

-

-

... More
3.0 TR - Cassette Type

9

-

-

... More
2.0 TR - Hi wall split Type

113

-

-

... More
SITC Copper Refrigerant piping duly insulated with pipe sleeves, supports, clamps, fittings, connections etc. in a concealed manner in the wall as per detailed drawings as per Manufacturer's Recommendation

-

-

-

... More
For 3.0 TR - Cassette Type

90

-

-

... More
For 2.0 TR - Hi wall split Type

565

-

-

... More
PVC drain piping for connection only with the existing Building Drain pipes.

-

-

-

655

-

-

10

-

-

... More
Electrical control wiring for interconnection between I/D & O/D units as per Manufacturer's recommendation

-

-

-

... More
For 3.0 TR - Cassette Type

90

-

-

... More
For 2.0 TR - Hi wall split Type

565

-

-

... More
Providing and fixing Powder Coated MS Stand for Outdoor Units as per Manufacturer's specifications as per details below -

-

-

-

... More
Wall Mounted Stand

113

-

-

... More
Double Decker Type Floor Mounted Stand

2

-

-

... More
Chowki Type floor Stand

5

-

-

-

-

-

... More
Suppy, installation, testing & commissitioning and putting into operation and final testing of automatic lift complete with all standard equipments, accessories and control equipments as per manufacturer's design and as per Latest NBC and fulfilling following requirments on turn key basis. Lifts Must have ARD unit.

-

-

-

... More
Type: Passenger lift

-

-

-

... More
Load: 8 passenger/ 544 Kg

-

-

-

... More
Speed: 1.0 metre per second

-

-

-

... More
Contol: AC2

-

-

-

... More
Operation: Microprosser based simplex collective selective with/ without lift attendent

-

-

-

... More
Total rise: G+2 About 9 mtrs

-

-

-

... More
Landings: 3 All on same side

-

-

-

... More
Signals: Digital car position indicator, car travel direction, indicators in car & at all landings

-

-

-

... More
Lift shaft size: About 1900 mm width X 1900 mm depth, finished with plaster

-

-

-

... More
Lift car size: About 1300 mm width X 1100 mm depth

-

-

-

... More
Car entrance: Clear opening 800mm

-

-

-

... More
Car door: Stainless steel two pannel centre opening flush type

-

-

-

... More
Landing door: Mild steel two pannel centre opening flush type

-

-

-

... More
Door operation: Automatic electric power operated door with infra red protection

-

-

-

... More
Car interior: Stainless steel pannel with hair line finish on all sides

-

-

-

... More
Car floor: Mild Steel covered with PVC

-

-

-

... More
Car ceiling & lighting: Fluorscent lighting concealed by

-

-

-

... More
suspended false ceiling with plain acrylic diffuser.

-

-

-

... More
Car ventilation : Pressure fan with anodised aluminium grill

-

-

-

... More
Emergency lighting in car: Battery operated Emergency lighting in the lift car.

-

-

-

... More
Intercom system: Battery operated Intercom system in lift car, machine room and control room.

-

-

-

... More
Emergency alarm: Battery operated alarm bell system in lift car & contol room

-

-

-

... More
Position of machine room: Directly above the lift shaft

-

-

-

... More
Electric power supply: AC 415 Volts 3 phase 50 Hz terminated in machine room

-

-

-

... More
Fire man switch: Fire man switch at main landing terminal.

2

-

-

... More
Suppy, installation, testing & commissitioning and putting into operation and final testing of automatic lift complete with all standard equipments, accessories and control equipments as per manufacturer's design and as per Latest NBC and fulfilling following requirments on turn key basis. Lifts Must have ARD unit.

-

-

-

... More
Type: Passenger lift

-

-

-

... More
Load: 13 passenger/ 844 Kg

-

-

-

... More
Speed: 1.0 metre per second

-

-

-

... More
Contol: AC2

-

-

-

... More
Operation: Microprosser based simplex collective selective with/ without lift attendent

-

-

-

... More
Total rise: G+2 About 9 mtrs

-

-

-

... More
Landings: 3 All on same side

-

-

-

... More
Signals: Digital car position indicator, car travel direction, indicators in car & at all landings

-

-

-

... More
Lift shaft size: About 1900 mm width X 1900 mm depth, finished with plaster

-

-

-

... More
Lift car size: About 1300 mm width X 1100 mm depth

-

-

-

... More
Car entrance: Clear opening 2400 x 1000 mm

-

-

-

... More
Car door: Stainless steel two pannel centre opening flush type

-

-

-

... More
Landing door: Mild steel two pannel centre opening flush type

-

-

-

... More
Door operation: Automatic electric power operated door with infra red protection.

-

-

-

... More
Car interior: Stainless steel pannel with hair line finish on all sides

-

-

-

... More
Car floor: Mild Steel covered with PVC

-

-

-

... More
Car ceiling & lighting: Fluorscent lighting concealed by suspended false ceiling with plain acrylic diffuser.

-

-

-

... More
Car ventilation : Pressure fan with anodised aluminium grill

-

-

-

... More
Emergency lighting in car: Battery operated Emergency lighting in the lift car.

-

-

-

... More
Intercom system: Battery operated Intercom system in lift car, machine room and control room.

-

-

-

... More
Emergency alarm: Battery operated alarm bell system in lift car & contol room.

-

-

-

... More
Position of machine room: Directly above the lift shaft

-

-

-

... More
Electric power supply: AC 415 Volts 3 phase 50 Hz terminated in machine room.

-

-

-

... More
Fire man switch: Fire man switch at main landing terminal.

2

-

-

... More
FIRE FIGHTING WORKS

-

-

-

... More
FIRE FIGHTING PUMPS & EQUIPMENTS

-

-

-

... More
Supplying Installation, testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following Complete in all respect as required.

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 LPM and 60 Metres head conforming to IS 1520. (The pump should be capable of delivering 150 % rated disCharge at a head not less than 65% of the rated head).

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable Cement Concrete foundation with cement concrete plaster as per manufacturers design, complete with anti-vibration arrangement.

-

-

-

... More
Site Level

1

-

-

... More
Supplying, Installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following : complete in all respect as required.

-

-

-

... More
Horizontal type,multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 LPM at outlet head 60 Metres conforming to IS 1520. (The pump should be capable of delivering 150 % rated disCharge at a head not less than 65% of the rated head).

-

-

-

... More
Suitable HP 1500 RPM diesel engine conforming to BS :649/IS:1601/IS:10002 all amended upto date, continuous duty, multi cylinders vertical 4 stroke cycle water cooled, developing suitable BHP at operating speed specified to drive the fire pump capable of driving continuous non-stop operation for 8 hours having 10% overload capacity for one hour in a period of 12 hours continuous run, capacity to accept full load within 15 seconds from the receipt of signal to start and complete with following accessories:

-

-

-

... More
i) Dynamically balanced fly-wheel. ii) Direct coupling for pump and coupling guards. iii) Radiator with hoses, fan water pump, drive arrangement and guard. iv) Air-cleaner dry type v) Fuel tank with necessary pipe. vi) Pump for lubricating oil and lubricating oil filter. vii) Electric starting system alongwith battery 12 V / 24 V. viii) Exhaust siliencer(residential type) with necessary pipe work. ix) Governor x) Instrument panel housing all the gauges including tachometer, hour meter and starting switch with key (for manual starting xi) Necessary safety controls.and stop solenoid in the event of fault xii) Winterization arrangement. xiii) Hand operated semi-rotary hand pump for filling the service tank xiv) required length of exhaust piping as per the norms duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding (xv)Painted in post office red colour

-

-

-

... More
Common bed plate fabricated out of MS channel of suitable size for assembling the Pump and the Engine, flexible coupling and with coupling guard for protection/safety.

-

-

-

... More
Making cement concrete foundation of 1:2:4 ratio (1 Cement: 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) duly plastered suitable for Diesel engine pump set including vibration isolation by providing cushy foot mount pads as necessary, foundation bolts, brackets, clamps, fixtures, grouting etc, in accordance with manufacturer's design etc.as per specification complete as reqd.

-

-

-

... More
Site Level

1

-

-

... More
Supplying Installation, testing and Commissioning of jocky fire pump suitable for automatic operation and consisting of following Complete in all respect as required.

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 180 LPM and 80 Metres head conforming to IS 1520. (The pump should be capable of delivering 150 % rated disCharge at a head not less than 65% of the rated head).

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable Cement Concrete foundation with cement concrete plaster as per manufacturers design, complete with anti-vibration arrangement.

-

-

-

... More
Site Level

1

-

-

... More
Supplying, Installation, Testing and Commissioning of electric driven Terrace pump suitable for automatic operation and consisting of following: complete in all respect as required.

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 450 LPM at 40 m. head confirming to IS : 1520

-

-

-

... More
Suitable HP SQ cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325

-

-

-

... More
M.S. Fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
The pump shall include suitable weather proof electrical panel with all type of cables,tray,mcbs etc which ever is required.Take approval of panal design from consultnt/client before installation.

-

-

-

... More
It includes weather proof electrical panal with all required sutable starter assoseries complete as required.

-

-

-

... More
Pump shall be enclosed with M.S. sheet to protect from weather at terrace.

-

-

-

... More
Site Level

1

-

-

... More
Hydrants, Piping & Accessories

-

-

-

... More
Supplying, laying, fixing, testing and commissioning of following sizes (NB) of class 'C' M.S. pipes confirming to IS 1239 and 3589 including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/slabs and making good the same etc. complete in all respect as required.

-

-

-

... More
200 mm dia

-

-

-

... More
Site Level

20

-

-

... More
100 mm dia

-

-

-

... More
Institute Building

135

-

-

... More
Hostel Building

185

-

-

... More
80 mm dia

-

-

-

... More
Institute Building

30

-

-

... More
Hostel Building

35

-

-

... More
Providing & fixing of heavy class M.S. pipes conforming to IS: 1239/3589 complete with fittings including trenching and refilling etc. (external work) including all fittings and accessories like tees, elbows, flanged joints, rubber insertion, nuts, bolts or cutting and welding joints. Providing thrust block at distance specified as per specifications. (Pipe shall be provided with anti corrosive protective treatment with coal tar/asphalt tape confirming to IS: 10221 standard complete as per specification). All work complete as per specification and as directed by Engineer-In-Charge.

-

-

-

... More
150 mm dia

-

-

-

... More
Institute Building

135

-

-

... More
80 mm dia

-

-

-

... More
Site Level

25

-

-

... More
Suplying, installing, testing and commissioning of following dia Y Strainer of ductile body flanged with stainless steel strainer as required.

-

-

-

... More
150 mm dia

-

-

-

... More
Site Level

2

-

-

... More
100 mm dia

-

-

-

... More
Institute Building

1

-

-

... More
Hostel Building

1

-

-

... More
80 mm dia

-

-

-

... More
Site Level

1

-

-

... More
Providing, Installation, Testing and Commissioning of double flanged cast iron Dual Plat Check Valve, PN 1.6 of following sizes confirming to IS : 5312 complete with EPDM rubber lining seat and stainless steel disc, rubber gasket, Gl bolts, nuts, washers etc. as required.

-

-

-

... More
100mm dia

-

-

-

... More
Institute Building

2

-

-

... More
Hostel Building

2

-

-

... More
150 mm dia

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

3

-

-

... More
80 mm dia

-

-

-

... More
Institute Building

2

-

-

... More
Hostel Building

2

-

-

... More
Supplying of Butterfly valves of PN 1.6rating of following sizes with EPDM rubber lining seat and CF-8 stainless steel disc duly ISI marked and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects confirming to IS: 13095 as required.

-

-

-

... More
200 mm dia

-

-

-

... More
Site Level

2

-

-

... More
150mm dia

-

-

-

... More
Site Level

6

-

-

... More
100 mm dia

-

-

-

... More
Institute Building

8

-

-

... More
Hostel Building

10

-

-

... More
80 mm dia

-

-

-

... More
Institute Building

5

-

-

... More
Hostel Building

4

-

-

... More
Site Level

2

-

-

... More
65 mm dia

-

-

-

... More
Site Level

1

-

-

... More
Supplying and fixing Single Headed Internal Hydrant Valve oblique pattern with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS : 5290 (Type A), with 80 mm dia flanged inlet, with ABS cap and chain complete with all accessories etc. as required.

-

-

-

... More
Institute Building

10

-

-

... More
Hostel Building

10

-

-

... More
Supply, Installation, Testing and Commissioning 63 mm dia. 15 Mtr. Long RRL hose pipe with 63 mm dia. male and female stainless steel couplings duly binded with GI wire rivets etc. ISI marked, IS 636 (type-A) as required.

-

-

-

... More
Institute Building

20

-

-

... More
Hostel Building

20

-

-

... More
Supplying and Fixing First Aid Hose Reel, wall mounting swinging type complete with drum & bracket of MS construction, spray painted in Post office Red, confirming to IS 884/1995 with upto date amendments, complete with the following as required.

-

-

-

... More
Connection from riser with 25 mm dia gun metal stop valve and M.S pipe as reqd.

-

-

-

... More
Institute Building

10

-

-

... More
Hostel Building

10

-

-

... More
Supplying and fixing Stainless Steel branch pipe with 20mm dia nozzle conforming to IS:903. suitable for instantaneous connections to hose pipe coupling etc. as required.

-

-

-

... More
Institute Building

10

-

-

... More
Hostel Building

10

-

-

... More
Supplying and fixing 2 way FBC of CI body with 3 no. Stainless Steel male instantaneous inlet couplings complete with cap and chain as required. For 150mm dia M.S Pipe connection conforming to IS: 904 as required.

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

4

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia Stainless Steel wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

4

-

-

... More
Site Level

1

-

-

... More
Providing & Fixing Pressure switch in the M.S Pipe Line including connection etc. as required.

-

-

-

... More
Institute Building

1

-

-

... More
Hostel Building

1

-

-

... More
Providing,fixing,testing and commissioning 100 mm dia pressure gauge of range 0 -015 Kg / sqcm conforming to IS - 3624 having bourdon tube of stain steel 310 in cast aluminium,stove enamelled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock complete as required.

-

-

-

... More
Institute Building

3

-

-

... More
Hostel Building

4

-

-

... More
Site Level

5

-

-

... More
Supplying, installation, testing and commissioning of M.S cabinet size 1000 mm x 2100 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements.

-

-

-

... More
Institute Building

10

-

-

... More
Hostel Building

10

-

-

... More
SITC of Fire Man's Axe

-

-

-

... More
Supplying, Installation, Testing and Commissioning of standard Fire Man's axe with heavy insulated rubber conforming to IS : 926

-

-

-

... More
Institute Building

10

-

-

... More
Hostel Building

10

-

-

... More
Supplying and fixing 4 way fire brigade connection of cast iron body with 4 nos. Stainless steel male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required.

-

-

-

... More
Site Level

2

-

-

... More
Providing,fixing,testing and commissioning of one number Stainless steel fire brigade section hose coupling (Fire brigade withdrawal connection) i/c foot valve in the bottom etc. as per specification complete as required. (M.S pipe of 100 mm dia will be paid in pipe item.

-

-

-

... More
Site Level

1

-

-

... More
Electrical Panels for Fire Fighting system

-

-

-

... More
Fabricating, supplying, installation, testing and commissioning of electrical control panel of cubical construction,floor mounted type , fabricated from 2 mm thick CRCA sheet compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatrment process,cable alley,inter connection, having switchgears and accessories mounting and internal wiring, earth terminals numbering etc complete in all respect ,suitable for operation on 415 V ,3 phase,50 Hz AC supply with enclosure protection class IP 42 as reqd

-

-

-

... More
PANEL IN FIRE PUMP HOUSE

-

-

-

... More
INCOMER

-

-

-

... More
i)400A, 4 pole, 50 KA,MCCB with microprocessor release with Ics=100%Icu digital Voltmeter (0-500 Volts) with selector switch. digital Ammeter (0-400Amps) with in built selector switch and CT's etc.Set of 3 Phase LED indicating lamps,Set of Al. bus bar for 400 Amps. --1 Set

-

-

-

... More
OUTGOING.

-

-

-

... More
a) Main fire pump.

-

-

-

... More
i)250Amps. TP MCCB,35/36 KA Ics=100%Icu with suitable HP fully automatic star/delta starter with over load protection, (without no volt and under voltage trip) current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local /remote, auto/manual/OFF operation.--- 1set

-

-

-

... More
ii)Digital ammeter with selector switch alongwith suitable ratio CTs---1 Set

-

-

-

... More
iii)Pumpon LED Indication lamp --- 1 No.

-

-

-

... More
b) Jockey pump.

-

-

-

... More
i)63Amps. TP MCCB 25 KA Ics=100%Icu with suitable HP fully automatic star/delta starter with over load protection,( without no volt and under voltage trip), current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local / remote, auto/manual OFF operation.-2 sets.

-

-

-

... More
ii) Digital ammeter with selector switch alongwith suitable ratio CTs-1 Set.

-

-

-

... More
iii) Pump on LED Indication lamp - 1 No.

-

-

-

... More
c) Diesel Engine Control

-

-

-

... More
Control for Diesel Engine comprising:- Auto/Manual selector switch and 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode.Indication lamp for High/Low Lub. Oil pressure,High Water Temp.and Engine ON indication Battery Charger suitable for 12/24 V DC with boost and tickle selector switch, 0-30 V DC volt meter, 0-20A DC Ammeter.All standard relays and accessories for automatic operation of diesel engine.

-

-

-

... More
d) SYSTEM CONTROLLER

-

-

-

... More
Designing, Supply, Installation, Testing and Commissioning of System controller to control operation of Main Electric Fire Pump, Diesel Pump, Pressurisation Pump in sequence as per specification consisting of relays, timers, sensors, annunciation window for fault indication, complete as per specification.

-

-

-

... More
Site Level

1

-

-

... More
PRESSURISATION PUMP AND TERRACE PUMP CONTROL

-

-

-

... More
INCOMING

-

-

-

... More
40 Amps. TP&N MCB

-

-

-

... More
Voltmeter (0-500 Volt) with selector Switch.

-

-

-

... More
Ammeter (0- 40. Amps.) with selector switch & Cts

-

-

-

... More
Set of 3 phase indication lamp

-

-

-

... More
60 Amp TPN Aluminum Bus Bar

-

-

-

... More
Suitable HP fully automatic DOL Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.

-

-

-

... More
Selector switch for local/remote, auto/manual/off operation ON/OFF indication lamp etc(Required in Ground Floor).

-

-

-

... More
Site Level

1

-

-

... More
Supplying and Laying of XLPE insulated, PVC sheathed 1.1 KV grade armoured U.G. Cable of following sizes on surface/in existing cable tray suitably clamped as required.

-

-

-

... More
31/2 x 240 Sqm.m.(aluminium conductor)

-

-

-

... More
Site Level

50

-

-

... More
3 x 70 Sqm.m(aluminium conductor)

-

-

-

... More
Site Level

30

-

-

... More
3 x 10 Sq mm (Copper conductor)

-

-

-

... More
Site Level

30

-

-

... More
2 x 2.5 Sq mm (Copper conductor)

-

-

-

... More
Site Level

50

-

-

... More
Supplying and making end termination with brass compression gland and Al./Copper lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al. /Copper conductor cables of 1.1 KV grade as required.

-

-

-

... More
31/2 x 240 Sqm.m.(aluminium conductor)

-

-

-

... More
Site Level

2

-

-

... More
3 x 70 Sqm.m(aluminium conductor)

-

-

-

... More
Site Level

4

-

-

... More
3 x 10 Sq mm (For Copper conductor)

-

-

-

... More
Site Level

4

-

-

... More
2 x 2.5 Sq mm (Copper conductor)

-

-

-

... More
Site Level

8

-

-

... More
Suppling and fixing following sizes of perforated pre-painted M.S cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required.

-

-

-

... More
150 mm. (W) X 50 mm. (D) X 1.6mm.(TH)

-

-

-

... More
Site Level

30

-

-

... More
300 mm. (W) X 50 mm. (D) X 1.6mm (TH)

-

-

-

... More
Site Level

20

-

-

... More
Providing and fixing 25 mm x 5 mm G.I.Strip in on surface or in recess for loop earthing complete etc. as required.

-

-

-

... More
Site Level

50

-

-

... More
Providing and fixing mettalic expansion bellows vibration eliminators with flange suitable for raw water upto 45 deg. C. temperature working pressure 7 kg/ sq.cm and test pressure 14 kg/sq.cm.

-

-

-

... More
80mm dia

-

-

-

... More
Site Level

2

-

-

... More
150 mm dia

-

-

-

... More
Site Level

4

-

-

... More
FIRE EXTINGUISHERS

-

-

-

... More
Providing and fixing with bracket/supports etc. wall mounted fire extinguishers as per detail below:

-

-

-

... More
Providing and fixing water based CO2 type extinguishers consisting of welded M.S. cylindrical body, squeeze lever disCharge valve 30 cms long high pressure disCharge hose, disCharge nozzle, suspension bracket, ISI marked as per IS:934 finished externally with red enamel paint and fixed to wall with brackets complete with internal Charges.

-

-

-

... More
Capacity 9 lit.

-

-

-

... More
Institute Building

36

-

-

... More
Hostel Building

48

-

-

... More
Site Level

-

-

-

... More
Providing and fixing fire extinguisher of water stored type extinguisher with cylinder fully Charged with 6ltr capacity.

-

-

-

... More
Institute Building

12

-

-

... More
Hostel Building

16

-

-

... More
Site Level

-

-

-

... More
ABC Modular Type Fire Extinguisher 9 Kg capacity filled with MAP 70% ABC Powder complete in all respect.

-

-

-

... More
Institute Building

6

-

-

... More
Hostel Building

6

-

-

... More
Site Level

-

-

-

... More
HORTICULTURE WORKS

-

-

-

... More
Supply of Plants

-

-

-

... More
Supplying and planting best quality container- grown healthy trees of species as specified. All trees to be approved before planting. Inclusive of maintenance as specified for one year after planting.(all plants are acclimatized, disease less and foliage as per the height, sets & required proportions) including cost of all materials,conveyance, labour,T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
TREES:

-

-

-

... More
Supply and stacking of ACACIA BIFLORA as per direction of the Engineer-in-Charge.

70

-

-

... More
Supply and stacking of Alstonia scholaris plant of height 150-165 cm. in as per direction of the Engineer-in-Charge. bag of size 25 cm as per direction of the Engineer-in-Charge

156

-

-

... More
Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the Engineer-in-Charge.

95

-

-

... More
Supply and stacking of Bauhinia purpurea (Kachnar) plant of height 150- 165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-Charge.

82

-

-

... More
Supply and stacking of Bauhinia Alba as per direction of the Engineer-in-Charge.

53

-

-

... More
Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-Charge

77

-

-

... More
Supply and stacking of Cassia siamea plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-Charge.

69

-

-

... More
Supply and stacking of Chorisia speciosa plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-Charge.

112

-

-

... More
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the Engineer-in-Charge

74

-

-

... More
Supply and stacking of Ficus benjamina (green) plant of height 120-135cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the Engineer-in-Charge.

185

-

-

... More
Supply and stacking of Lagerstroemia Parviflora as per direction of the Engineer-in-Charge.

66

-

-

... More
Supply and stacking of Lagerstroemia flosreginae plant of height 150-165 cm.in big poly bag of size 25 cm as per direction of the Engineer-in-Charge

91

-

-

... More
Supply and stacking of Mimisops Elengi as per direction of the Engineer-in-Charge.

42

-

-

... More
Supply and stacking of Plumeria alba plant of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the Engineer-in-Charge

224

-

-

... More
Supply and stacking of Polyalthia Longifolia as per direction of the Engineer-in-Charge.

44

-

-

... More
Supply and stacking of plant Tecoma stans of height 45-60 cm. branched in earthen pots of size 20 cm as per direction of the Engineer-in-Charge

48

-

-

... More
Supply and stacking of Peltophorium Ferrignum as per direction of the Engineer-in-Charge.

12

-

-

... More
PALMS AND LANDSCAPING PLANTS

-

-

-

... More
Supply and stacking of Fishtail palm plant of ht. 150-180 cm bottom girth 15-20 cm well developed in big poly bags of size 25 cm as per direction of the Engineer-in-Charge

10

-

-

... More
Providing and Displaying Fishtail palm plant well developed with fresh &healthy foliage leaves of ht 210 to 240cm Specimen plant in 35 cm Cement Pot as per direction of the Engineer-in-Charge.

10

-

-

... More
Providing and Displaying Latania Rubra Palm plant well developed with fresh & healthy foliage 150 to 180 cm ht. with 6 to 7 leaves in big 35 cm Cement Pot as per direction of the Engineer-in-Charge.

10

-

-

... More
Supply and stacking of Foxtail palm plant of ht. 180-210 cm bottom girth 25-30 cm well developed in big size HDPE bags as per direction of the Engineer-in-Charge.

10

-

-

... More
Providing and Displaying Foxtail palm plant well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the Engineer-in-Charge.

10

-

-

... More
SHRUBS

-

-

-

... More
Supplying and planting best quality pot-grown healthy shrubs minimum 450mm tall of species specified, inclusive of preparation and cultivation of shrub beds as specified. All plants to be approved before planting. Inclusive of maintenance as specified for one year after planting. (all plants are acclimatized, disease less and foliage as per the height, sets & required proportions) including cost of all materials,conveyance, labour,T&P, etc, all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
Providing and Displaying of Duranta Golden plant, having ht.15 to 20 cm bushty shape plant with fresh and healthy leaves in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the Engineer-in-Charge..

118

-

-

... More
Supply and stacking of plant Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the Engineer-in-Charge.

207

-

-

... More
Supply and stacking of plant Hibiscus rosasinensis of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the Engineer-in-Charge.

54

-

-

... More
Supply and stacking of plant Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the Engineer-in-Charge.

308

-

-

... More
Supply and stacking of Ixora Chinensis as per direction of the Engineer-in-Charge.

130

-

-

... More
Supply and stacking of Eranthemum Bicolour as per direction of the Engineer-in-Charge.

65

-

-

... More
Supply and stacking of Eranthemum Tricolour as per direction of the Engineer-in-Charge.

72

-

-

... More
Supply and stacking of plant Largerstroemia indica of height 90-105 cm. multibranched in poly bags of size 25 cm as per direction of the Engineer-in-Charge.

485

-

-

... More
Supply and stacking of plant Tabernaemontana coronaria (Chandni single) of height 45-60 cm. in earthen pots of size 20 cm as per direction of the Engineer-in-Charge.

220

-

-

... More
Supply and stacking of plant Tabernaemontana coronaria (chandni variegated) of height 45-60 cm. with 3-4 branches earthen pots of size 20 cm as per direction of the Engineer-in-Charge

425

-

-

... More
Supply and stacking of plant Ficus Nitida as per direction of the Engineer-in-Charge.

175

-

-

... More
Supply and stacking of Ficus benjamina (green) plant of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the Engineer-in-Charge

550

-

-

... More
Supply and stacking of Ficus bengalensis (varigated) plant of height 75-90 cm.,multibranchedin earthen pots of size 30 cm as per direction of the Engineer-in-Charge.

620

-

-

... More
Supply and stacking of Callendra as per direction of the Engineer-in-Charge.

114

-

-

... More
Supply and stacking of Tecoma Capensis as per direction of the Engineer-in-Charge.

65

-

-

... More
Cesalpiniea: Supply and stacking of plant Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the Engineer-in-Charge

84

-

-

... More
Supply and stacking of Cardyline as per direction of the Engineer-in-Charge.

244

-

-

... More
Providing of Schefflera high colour plant, having ht. 23 cm to 30 cm, well developed with fresh & healthy foliage in 20 cm size of Earthen pot / Plastic pot.

285

-

-

... More
Providing and displaying of Dracaena Song of India plant (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot / Plastic pot & as per direction of the Engineer-in-Charge

207

-

-

... More
Supply and stacking of Galphimia as per direction of the Engineer-in-Charge.

130

-

-

... More
Providing and Displaying Topiary plant of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm ht., in 35 cm Cement Tray /Cement Pot as per direction of the Engineer-in-Charge.

1500

-

-

... More
GROUND COVER

-

-

-

... More
Providing and Displaying of Syngonium (Butterfly) variegated plant with 2- 3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the Engineer-in-Charge.

1500

-

-

... More
Providing and Displaying of Asparagus marrie plant, well developed 15 to 20 leaves, full of branches and foliage in 25 cm size of Earthen Pot / Plastic Pot & as per direction of the Engineer-in-Charge.

1250

-

-

... More
Supply and stacking of Syngonium Green as per direction of the Engineer-in-Charge.

1100

-

-

... More
Providing and Displaying of Wadelia trilobata plant,full of leaves in 15 cm size of Poly bags & as per direction of the Engineer-in-Charge.

1250

-

-

... More
AUDIO VISUAL WORKS

-

-

-

... More
GROUND FLOOR

-

-

-

... More
Ground Floor - Learning Centre (x 3)

-

-

-

... More
SITC of 75" 4K Interactive LED Display having minimum following specifications: Display should be of 75" 4K 3840*2160 of Pixel and Infrared based 10 touch Interactive screen or better. Should have Tempered Glass or better for added protection. Should have HDMI x4, VGA x1, DP x1, USB x1 Input ports and HDMI Out x1 or more. Built-in Android System. Should have 15W x 2 Speakers for good audio or more. Should have a slot to accommodate OPS to unlease possibilities of using Windows without connecting external PC/Laptop. Should be have built-in WiFi and LAN ports to connect the display to internet. Makes: Newline/Samsung/Philips

3

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 75" to 86" Makes: Chief/Lumi/Btech Mounts

3

-

-

... More
SITC of OPS PC for LED Display having minimum following specifications: CPU should be i5 @1.3GHz or better Should have 4GB RAM or more, Should have HDMI x1, VGA x1, USB x4 Input ports or more Should have 500GB HDD or more Should have 1 RJ45 port for Internet or more Should have built-in Wifi Should be fitted inside display and able to take power from the display itself. Makes: Newline/Samsung/Philips

3

-

-

... More
Publication Counter

-

-

-

... More
SITC of 65" 4K Interactive LED Display having minimum following specifications: Display should be of 65" 4K 3840*2160 of Pixel and Infrared based 10 touch Interactive screen or better Should have Tempered Glass or better for added protection, Should have HDMI x4, VGA x1, DP x1, USB x1 Input ports and HDMI Out x1 or more Built-in Android System Should have 15W x 2 Speakers for good audio or more Should have a slot to accommodate OPS to unlease possibilities of using Windows without connecting external PC/Laptop Should be have built-in WiFi and LAN ports to connect the display to internet Makes: Newline/Samsung/Philips

1

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

1

-

-

... More
Discussion Area

-

-

-

... More
SITC of Motorized Projection Screen having minimum following specifications: It should be 84" (6'x4') diagonaly in 4:3 Ratio. Fabric should be Matte White Finish or better Should have salient Motor for smooth and quiet operation Should have A wired Remoted Should have a Wireless Remote or ease of control. Makes: Draper/Da-Lite/Liberty

1

-

-

... More
SITC of WXGA Ultra Short Throw Projector having minimum following specifications: Projector should be of 3300lm ANSI Brightness or more It should have Resolution of 1280 x 800 (WXGA) or better Should have HDMI x2, VGA x2, Composite x1 Input ports and VGA Out x1 or more Should have at least 10W built-in Speakers or more Aspect Ratio 16:10 Native, 16:9/4:3 Compatible Horizontal Scan Rate 15.3 - 91.1kHz Vertical Scan Rate 24 - 85Hz (120Hz for 3D) Contrast Ratio 18000:1,Keystone Correction ± 15° Vertical Makes: Benq,Optoma ,Hitachi

1

-

-

... More
SITC of Cable Manager having minimum following specifications: It should have Access Enclosure for AV Connectivity It should have Multi-Region Power Socket x2 or more Should have HDMI x1, VGA x1, 3.5mm x1 and LAN x1 Connections or more Should have metal enclosure or better Should be compatible for a table thickness of 0.5" to 2.5" or more Makes: Extron/Crestron/AMX

1

-

-

... More
SITC of Wireless Presentation Gateway having minimum following specifications: It should have Dual WiFi Bands (2.4GHz and 5GHz) or better. It should support up to 64 Devices or more Should have HDMI x1, VGA & Audio x1 Output, RJ45 x1 and USB2.0 x3 Inputs or more Should have iOS AirPlay Mirroring. Should be able to projector 4 devices simultaneously Makes: Newline/InFocus/Barco

1

-

-

... More
SITC of two-way 5.25" Powered Speakers set having minimum following specifications: It should have 5.25" Woofer size and 1" Tweeter size or better It should have 1 active and 1 passive loudspeaker or more Should have low impedance dynamic power of 2x30W or more Should have max SPL @1m 101dB or more. Should be IP 40 Rated or better Should have frequency response of 45Hz to 20KHz. Should have vertical and horizontal dispersion angle of 180 degree @1000Hz Makes: Apart Audio/Aimline/Martin Audio

1

-

-

... More
VIP Lounge

-

-

-

... More
SITC of 65" Full HD LED Display having minimum following specifications: Display should be 65" Full HD or Better hould have HDMI DP x1, DVI-I x1 or more Output Ports Should have HDMI x2, VGA&Audio x1, DP x1, DVI-D x1, USBx1 or more input ports It should have Brightness of 350 cd/sqm Should have 10W x 2 Speakers for good audio or more Should have typical contrast ratio of 3000:1 or better Should be have built-in LAN ports and SmartCMS to push content from network Makes: Newline/Samsung/Philips

2

-

-

... More
SITC of Pop-Down TV Ceiling Lift Makes: Flatlift/Innovation System/Draper

2

-

-

... More
SITC of 1:2 HDMI Distribution Amplifier having minimum following specifications: It should have 1 HDMI input and 2x HDMI Outputs or More Should Support computer and video resolutions up to 4K or better Should have data rates up to 10.2 Gbps, Deep Color up to 12‑bit, 3D, and HD lossless audio formats or better It should be HDCP compliant Makes: Extron/Crestron/AMX

1

-

-

... More
Dining Lounge

-

-

-

... More
SITC of 55" Full HD LED Display having minimum following specifications: Display should be 55" Full HD or Better Should have HDMI x1, VGA&Audio x1, Component(RCa) x1, DVI-D x1 or more input ports It should have Brightness of 350 cd/sqm Should have 10W x 2 Speakers for good audio or more Should have typical contrast ratio of 1200:1 or better Should be have built-in LAN ports and SmartCMS to push content from network Makes: Newline/Samsung/Philips

1

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

1

-

-

... More
Dining Hall

-

-

-

... More
SITC of 55" Full HD LED Display having minimum following specifications: Display should be 55" Full HD or Better Should have HDMI x1, VGA&Audio x1, Component(RCa) x1, DVI-D x1 or more input ports It should have Brightness of 350 cd/sqm Should have 10W x 2 Speakers for good audio or more Should have typical contrast ratio of 1200:1 or better Should be have built-in LAN ports and SmartCMS to push content from network Makes: Newline/Samsung/Philips

2

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

2

-

-

... More
SITC of 1:2 HDMI Distribution Amplifier having minimum following specifications: It should have 1 HDMI input and 2x HDMI Outputs or More Should Support computer and video resolutions up to 4K or better Should have data rates up to 10.2 Gbps, Deep Color up to 12‑bit, 3D, and HD lossless audio formats or better It should be HDCP compliant Makes: Extron/Crestron/AMX

1

-

-

... More
Reception

-

-

-

... More
SITC of 4mm LED based Video wall having following minimum features: It should have 4mm Pixel Pitch or better Should have module size of 864 x 864mm Module size or better Should have LED Display Controller Should have Video Wall Processor Should make a matrix of 5x3 Modules to make a screen size (in mm) of 4320 x 2592. Should have native brightness of 1500 cd/sqm Should have contrast ratio of 8000:1 or more Make: Delta/Samsung

1

-

-

... More
SITC of two-way 5.25" Powered Speakers set having minimum following specifications: It should have 5.25" Woofer size and 1" Tweeter size or better It should have 1 active and 1 passive loudspeaker or more Should have low impedance dynamic power of 2x30W or more Should have max SPL @1m 101dB or more. Should be IP 40 Rated or better Should have frequency response of 45Hz to 20KHz. Should have vertical and horizontal dispersion angle of 180 degree @1000Hz Makes: Apart Audio/Aimline/Tannoy

1

-

-

... More
SITC of 6.5" two-way Ceiiling Mount Speaker having minimum following specifications: It should have 6.5" Woofer size and 1" Tweeter size or better It should have multiple transformer tapping options of 20-10-5 Watts or more Should have low impedance dynamic power of 60W @8 ohm or more Should have max SPL @1m 104dB or more. Should have frequency response of 60Hz to 20KHz. Should have vertical dispersion angle of 180 degree @1000Hz Makes: Apart Audio/Aimline/Tannoy

6

-

-

... More
SITC of 120Watts Mixer amplifier which should have following specification: RMS output power 4 ohms 120 watts or mroe output power RMS 100 volts 120 watts or more line input unbalanced 4 or more emergency input yes priority levels 4 or more frequency response (in Hz) 60 - 20K or better power amp topology class-D Mic inputs 3 or more cooling system convection Approved Makes: Crown,Apart Audio,Labgruppen

1

-

-

... More
SITC of All call dynamic paging microphone which should have following specification: Should be equipped with a toggle switch that allows Talk - Off - Continuous talk or better Should have uni-directional pollar pattern or better Should have frequency response (in Hz) 80 - 12K or better Approved Makes: Apart Audio / Shure

1

-

-

... More
Media Player with HDMI Out (DTH or DVD Player) Makes:Philips,Sony,Onkyo

1

-

-

... More
Screening Centre

-

-

-

... More
SITC of Motorized Projection Screen having minimum following specifications: It should be 84" diagonaly in 16:9 Ratio format Fabric should be Matte White Finish or better Should have salient Motor for smooth and quiet operation Should have A wired Remoted Should have a Wireless Remote or ease of control. Makes: Draper/Da-Lite/Stewart/Liberty

1

-

-

... More
SITC of 1080p DLP Projetcor having minimum following specifications: Projector should be of 3200lm ANSI Brightness or more Resolution 1080p 1920 x 1080 or above Should have HDMI x2, Audio Out 3.5mm, 12V trigger, 3D-Sync, USB-A Power (1A) Should have 10W Built-in Speakers or more Aspect Ratio 16:9 Native, 4:3 Compatible Horizontal Scan Rate 15 - 91kHz Vertical Scan Rate 25 - 85Hz (120Hz for 3D) Contrast Ratio 25000:1,Keystone Correction ± 40° Vertical Lamp Type 195W or better Makes: Benq,Optoma ,Hitachi

1

-

-

... More
SITC of Ceiling Mount for Projector

1

-

-

... More
SITC of 5.25" Two way HiFi Speaker which should have following specification: Woofer size: 5.25 inch or more Tweeter size: 0.75 inch or more Low impedance dynamic power: 160 watts @6ohm or more Low impedance RMS power: 80 watts @6ohm or more Loudspeaker system: 2-way Main construction material: mdf wood or better Max SPL 1m: 108 dB or more Frequency response: 60 - 25K Hz or better IP Rating: 20 or more Grille main material: Cloth or better Make. Apart Audio/Aimline/Tannoy

7

-

-

... More
SITC of turn and tilt mount which should have following specification: It should be ideal to mount above speaker on wall. It should be able to turn and tilt for easy movement of speaker as desire. Make. Apart Audio/Aimline/Tannoy

7

-

-

... More
SITC of 8" HiFi Active Subwoofer which should have following specification: Woofer size: 8" inch or more Low impedance dynamic power: 125 watts @4ohm or more Low impedance RMS power: 60 watts @4ohm or more Main construction material: wood or better Max SPL 1m: 109 dB or more Frequency response: 20 - 180Hz or better IP Rating: 20 or more Grille main material: Cloth or better Make. Apart Audio/Aimline/Tannoy

2

-

-

... More
SITC of 9.2 Channel AVR which should have following specification: It should have 9 Channel Discrete power amplifier or more Should have power output of 165w @6ohm, (1kHz, 0.7% 2ch Drive) or more Should have Bluetooth, WiFi, Ethernet Port and AM/FM Tuner or more Should have total of 8 HDMI inputs for multiple source or more Should support 4k scaling or better Should have 5+1 Analog Audio Inputs or more Should have a total of 11 Speaker terminals or more Should have seperate 2 Subwoofer Outputs or more Should have metal front panel or better Should be less than 14kg Make. Denon/Marantz/Yamaha

1

-

-

... More
FIRST FLOOR

-

-

-

... More
Meeting Room

-

-

-

... More
SITC of Motorized Projection Screen having minimum following specifications: It should be 84" (6'x4') diagonaly in 4:3 Ratio. Fabric should be Matte White Finish or better Should have salient Motor for smooth and quiet operation Should have A wired Remoted Should have a Wireless Remote or ease of control. Makes: Liberty/Draper/Da-lite/Stewart

1

-

-

... More
SITC of WXGA DLP Projetcor having minimum following specifications: Projector should be of 3600lm ANSI Brightness or more Resolution 1280 x 800 or better Should have HDMI x2, VGA x1, Composite x1, USB x1 Input ports and VGA Out x1 or more Should have a 10W built-in Speakers or more Aspect Ratio 16:10 Native, 16:9/4:3 Compatible Horizontal Scan Rate 15.3 - 91.1kHz Vertical Scan Rate 24 - 85Hz (120Hz for 3D) Contrast Ratio 20000:1,Keystone Correction ± 40° Vertical Makes: Benq,Optoma ,Hitachi

1

-

-

... More
SITC of Scissor Lift for Projector Makes: Chief/Btech/Draper/AV Space

1

-

-

... More
SITC of Cable Manager having minimum following specifications: It should have Access Enclosure for AV Connectivity It should have Multi-Region Power Socket x2 or more Should have HDMI x1, VGA x1, 3.5mm x1 and LAN x1 Connections or more Should have metal enclosure or better Should be compatible for a table thickness of 0.5" to 2.5" or more Makes: Extron/Crestron/AMX

1

-

-

... More
SITC of Wireless Presentation Gateway having minimum following specifications: It should have Dual WiFi Bands (2.4GHz and 5GHz) or better. It should support up to 64 Devices or more Should have HDMI x1, VGA & Audio x1 Output, RJ45 x1 and USB2.0 x3 Inputs or more Should have iOS AirPlay Mirroring. Should be able to projector 4 devices simultaneously Makes: Newline/InFocus/Barco

1

-

-

... More
SITC of two-way 5.25" Powered Speakers set having minimum following specifications: It should have 5.25" Woofer size and 1" Tweeter size or better It should have 1 active and 1 passive loudspeaker or more Should have low impedance dynamic power of 2x30W or more Should have max SPL @1m 101dB or more. Should be IP 40 Rated or better Should have frequency response of 45Hz to 20KHz. Should have vertical and horizontal dispersion angle of 180 degree @1000Hz Makes: Apart Audio/Aimline/Tannoy

1

-

-

... More
Lecture Room (x3)

-

-

-

... More
SITC of 86" 4K Interactive LED Display having minimum following specifications: Display should be of 86" 4K 3840*2160 of Pixel and Infrared based 10 touch Interactive screen or better Should have Tempered Glass or better for added protection, Should have HDMI x4, VGA x1, DP x1, USB x1 Input ports and HDMI Out x1 or more Built-in Android System Should have 15W x 2 Speakers for good audio or more Should have a slot to accommodate OPS to unlease possibilities of using Windows without connecting external PC/Laptop Should be have built-in WiFi and LAN ports to connect the display to internet Makes: Newline/Samsung/Philips

3

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 75" to 86" Makes: Chief/Lumi/Btech Mounts

3

-

-

... More
SITC of Digital Podium with Touch monitor having minimum following specifications: Podium should be made of Wood or metal or better It should have a 21" Touch monitor or better It should be 10 finger touch monitor having capability to be used with stylus as well or better It should have Brightness of 250nits or more Podium should have basic connectivity ports like HDMI, VGA, USB and power and at least one XLR for Gooseneck mic or more on top Should have space to keep AV Equipments. Makes: AHA/Uni/

3

-

-

... More
SITC of gooseneck microphone which should have minimum following specifications: It should be a pre-polarised Condenser Microphone with Cardioid or better polar patter Should have frequency response of 50Hz to 20Hz or better. Should have Equivalent noise level 26dB (A) or better. The length of gooseneck should be 17.71" or more. It should have metal sturdy Metal body.. Makes: Sennheiser

3

-

-

... More
SITC of Head-worn microphone having minimum following specifications: Should have Pre-Polarised condenser Transducer or better Should have Cardioid Polar Pattern or better Should have Max SPL of 150dB or more It should have up to 24MHz Switching bandwidth Should have Signal to noise ratio 102dBA and 0.9% THD or better Transmitter sync should be on 2.4GHz Should have frequency response of 50Hz to 16kHz or more Should have operating time of up to 10 hours or more. Makes: Sennheiser

3

-

-

... More
SITC of Handheld Microphone having minimum following specifications: Should have dynamic Transducer or better Should have Cardioid Polar Pattern or better It should have up to 24MHz Switching bandwidth Should have Signal to noise ratio 102dBA and 0.9% THD or better Transmitter sync should be on 2.4GHz Should have frequency response of 80Hz to 16kHz or more Should have operating time of up to 10 hours or more. Makes: Sennheiser / Shure /

3

-

-

... More
SITC of 6 Input Presentation Swticher having minimum following specifications: Should have HDMI x4, VGA x2 as Inputs or more Should have Dual Simultaneous HDMI Outputs or more. Should have Two mic/line inputs with 48 volt phantom power or more It should have up to 24MHz Switching bandwidth Should have built-in HDMI audio embedding and De-embedding or better Should be HDCP-Compliant. Should have 1 bidirectional RS-232 and ethernet for external control or more Makes: Extron/Crestron/AMX

3

-

-

... More
SITC of 1:2 HDMI Distribution Amplifier having minimum following specifications: It should have 1 HDMI input and 2x HDMI Outputs or More Should Support computer and video resolutions up to 4K or better Should have data rates up to 10.2 Gbps, Deep Color up to 12‑bit, 3D, and HD lossless audio formats or better It should be HDCP compliant Makes: Extron/Crestron/AMX

3

-

-

... More
SITC of 6 Channel Audio DSP having minimum following specifications: Should have 6 Mic/Line inputs and 4 Mic/Line Output ports or more Should support Studio grade 24-bit/48 kHz analog-to-digital and digital-to-analog converters Should have Phantom power to connect gooseneck/boundary layer microphones It should have low latency DSP Processing or better Should have 2 Bidirectional RS-232 Ports and 1 ethernet port or more Should have A/D, D/A Conversion of 24bit, 48kHz sampling or more Makes: Extron/Crestron/AMX

3

-

-

... More
SITC of Dual Channel amplifier which should have following specification: The amplifier should have two channels which should provide 2 x 120 watts output power @ 100 volts or @ 4 ohms or more, It should be able to bridged into a powerful 240 watts @ 100 volts or 8 ohm single channel amplifier or better It should have 2 Balanced Line Inputs and 2 unbalanced line inputs or more It should have frequency response of 50Hz to 20kHz or more Should have Switching mode Power Supply technology or better Should be a Class-D Topology Power Amplifier or better Make: Apart Audio/Labgruppen/PowerSoft

3

-

-

... More
SITC of 6.5" Two way wall mount speaker which should have following specification: Woofer size: 6.5 inch or more Tweeter size: 1 inch or more 100V transformer power taps: 60 - 30 - 15 - 6 watts or more Low impedance dynamic power: 200 watts or more Loudspeaker system: 2-way Main construction material: ABS plastic Vertical dispersion angle 1000 Hz: 180° or more Horizontal dispersion angle 1000 Hz: 180° or more Max SPL 1m: 110 dB or better Frequency response: 65 - 20K Hz or better Grille main material aluminium Low Impedance 16 ohms Should be click Mount System. Make: Apart Audio/Aimline/Martin Audio

12

-

-

... More
SITC of Document Camera which should have following specification: It should have 5M CMOS 1/3.2" Sensor or better It should have 5x Optical and 10x Digital Zoom or more It should have HDMI x1 and VGA x1 Inputs or more Should have HDMI x1 and VGA x1 Outputs or more Shooting area @42cm should be 380mm*214mm or more Should have FHD projection @30fps or more Make: Newline

3

-

-

... More
SITC of Control Processor which should have following specification: It should have 512MB SDRAM and 4GB Flash Memory or more It should have 3 bidirectional RS-232 control Ports or more It should have 8 IR Ports or more It should have 8 Relay Ports or more It should support one SD or SDHC card up to 32 GB for memory expansion It should have RJ45 and USB ports It should be Rack Mountable Make: Extron/Crestron/AMX

3

-

-

... More
SITC of Touch Panel which should have following specification: It should have at least 7" screen or more It should have 16GB of internal Memory or more Should have WiFi for network Connectivity Make: Apple / Asus / Samsung

3

-

-

... More
SITC PC-Latest I-7 with minimum 16GB Ram, 2TB HDD, DVD Rom and a minimum 4 USB Ports and 4 HDMI Ports complete with 21" Monitor . Make: Lenovo / Dell / HP

1

-

-

... More
Training Centre

-

-

-

... More
SITC of 65" 4K Interactive LED Display having minimum following specifications: Display should be of 65" 4K 3840*2160 of Pixel and Infrared based 10 touch Interactive screen or better Should have Tempered Glass or better for added protection, Should have HDMI x4, VGA x1, DP x1, USB x1 Input ports and HDMI Out x1 or more Built-in Android System Should have 15W x 2 Speakers for good audio or more Should have a slot to accommodate OPS to unlease possibilities of using Windows without connecting external PC/Laptop Should be have built-in WiFi and LAN ports to connect the display to internet Makes: Newline/Samsung/Philips

1

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

1

-

-

... More
SITC of Cable Manager having minimum following specifications: It should have Access Enclosure for AV Connectivity It should have Multi-Region Power Socket x2 or more Should have HDMI x1, VGA x1, 3.5mm x1 and LAN x1 Connections or more Should have metal enclosure or better Should be compatible for a table thickness of 0.5" to 2.5" or more Makes: Extron/Crestron/AMX

1

-

-

... More
SITC of Wireless Presentation Gateway having minimum following specifications: It should have Dual WiFi Bands (2.4GHz and 5GHz) or better. It should support up to 64 Devices or more Should have HDMI x1, VGA & Audio x1 Output, RJ45 x1 and USB2.0 x3 Inputs or more Should have iOS AirPlay Mirroring. Should be able to projector 4 devices simultaneously Makes: Newline/InFocus/Barco

1

-

-

... More
Large VC Room (TP Room)

-

-

-

... More
SITC of Telepresence room which should have following specification: It should have 65" Display or better It should have 14 seater Horse Shoe Shape Table or more It should have 7 15" or better Touch content monitors It should have Video Codec and microphones Should have 3 12x Optical Zoom PTZ Camera or more It should come with required software or license for teleconferencing/Collaboration. It should be as a bundle solution of complete room with required accessories and equipments to make it work. Make: BOSPL/Cisco/Polycom

1

-

-

... More
Small VC Room

-

-

-

... More
SITC of 65" Full HD LED Display having minimum following specifications: Display should be 65" Full HD or Better hould have HDMI DP x1, DVI-I x1 or more Output Ports Should have HDMI x2, VGA&Audio x1, DP x1, DVI-D x1, USBx1 or more input ports It should have Brightness of 350 cd/sqm Should have 10W x 2 Speakers for good audio or more Should have typical contrast ratio of 3000:1 or better Should be have built-in LAN ports and SmartCMS to push connect from network Makes: Newline/Samsung/Philips

4

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

4

-

-

... More
SITC of Cable Manager having minimum following specifications: It should have Access Enclosure for AV Connectivity It should have Multi-Region Power Socket x2 or more Should have HDMI x1, VGA x1, 3.5mm x1 and LAN x1 Connections or more Should have metal enclosure or better Should be compatible for a table thickness of 0.5" to 2.5" or more Makes: Extron/Crestron/AMX

4

-

-

... More
SITC of Full HD Video Conference System having minimum following specifications: It should be Full HD Video Conference System with 12x Optical Zoom PTZ Camera or better It should have multi-party license to call at least 5 locations simultaneously or better It should be able to integrate with external mics and speaker systems It should come with an year of support or more Should be compatible for Dual Display Application Should have HDMI x1 and VGA x1 inputs for presentation sharing or more Should have 2 x USB 2.0 and 1 x RS-232, 8-pin mini-DIN or more Should have operating time of up to 10 hours or more. Makes: Polycom/Lifesize/PeopleLink

4

-

-

... More
SITC of 1:2 HDMI Distribution Amplifier having minimum following specifications: It should have 1 HDMI input and 2x HDMI Outputs or More Should Support computer and video resolutions up to 4K or better Should have data rates up to 10.2 Gbps, Deep Color up to 12‑bit, 3D, and HD lossless audio formats or better It should be HDCP compliant Makes: Extron/Crestron/AMX

4

-

-

... More
Emergency Room

-

-

-

... More
SITC of 4mm LED based Video wall having following minimum features: It should have 4mm Pixel Pitch or better Should have module size of 864 x 864mm Module size or better Should have LED Display Controller Should have Video Wall Processor Should make a matrix of 5x3 Modules to make a screen size (in mm) of 4320 x 2592. Should have native brightness of 1500 cd/sqm Should have contrast ratio of 8000:1 or more Make: Delta/Samsung

1

-

-

... More
SITC of Podium having minimum following specifications: Podium should be made of Wood or metal or better Should have connectivity point HDMI x1 or more Makes: AHA/Uni/

1

-

-

... More
SITC of Head-worn microphone having minimum following specifications: Should have Pre-Polarised condenser Transducer or better Should have Cardioid Polar Pattern or better Should have Max SPL of 150dB or more It should have up to 24MHz Switching bandwidth Should have Signal to noise ratio 102dBA and 0.9% THD or better Transmitter sync should be on 2.4GHz Should have frequency response of 50Hz to 16kHz or more Should have operating time of up to 10 hours or more. Makes: Sennheiser / Shure

1

-

-

... More
SITC of Handheld Microphone having minimum following specifications: Should have dynamic Transducer or better Should have Cardioid Polar Pattern or better It should have up to 24MHz Switching bandwidth Should have Signal to noise ratio 102dBA and 0.9% THD or better Transmitter sync should be on 2.4GHz Should have frequency response of 80Hz to 16kHz or more Should have operating time of up to 10 hours or more. Makes: Sennheiser / Shure

1

-

-

... More
SITC of Column Array Speaker which should have following specification: Should have 8x3.5" LF Drivers and at least 1 HF Driver or more Low impedance dynamic power: 320 watts @16ohm or more Horizontal coverage angle: 130° or more Max SPL 1w @1m: 106 dB or more Frequency response: 85Hz - 20kHz or better Should come with Mounting accessories Make: d&B Audio ,Lacoustics,Aimline-Audio,Martin Audio

2

-

-

... More
SITC of Dual Channel amplifier which should have following specification: The amplifier should have two channels which should provide 2 x 250 watts RMS @ 4 ohms or better, It should be able to bridged into a powerful 500 watts 8 ohm single channel amplifier or better It should have 2 Balanced Line Inputs and 2 unbalanced line inputs or more It should have frequency response of 10Hz to 24kHz or more Should have Switching mode Power Supply technology or better Should be a Class-D Topology Power Amplifier or better Make: Apart Audio/Labgruppen/PowerSoft

1

-

-

... More
SITC of 6 Channel Manual Mixer having following features: 6+2 channel frame sizes or more Should have 2 or more configurable auxiliary buses Should have XLR-type and ¼” metal jack connector sockets Should have RCA phono stereo playback inputs and record outputs Should have 3-band EQ with a swept mid on mono inputs Should have 2-band EQ on stereo inputs Should have TRS insert sockets and inserts on all mono inputs and mix output Shoudl have Ten-segment LED output metering Intuitive and comprehensive solo system Should have Headphone output Should be Easily rack mountablee Make: Yamaha/Soundcraft/Allen Heath

1

-

-

... More
SITC of AV equipment Rack having following Minimum Specifications: It should be 19" 12U AV Equipment Rack. Should have 600mm Depth or more Should have at least one Power Distribution Unit or more Should have Fan on the top to keep equipments cool Should come with Shevles and Blankers as required to keep equipments and manage cables inside the rack Make: MTS/Valrack/Rittal

1

-

-

... More
SECOND FLOOR

-

-

-

... More
Meeting Room

-

-

-

... More
SITC of Motorized Projection Screen having minimum following specifications: It should be 84" (6'x4') diagonaly in 4:3 Ratio. Fabric should be Matte White Finish or better Should have salient Motor for smooth and quiet operation Should have A wired Remoted Should have a Wireless Remote or ease of control. Makes: Draper/Da-Lite/Liberty

1

-

-

... More
SITC of WXGA DLP Projetcor having minimum following specifications: Projector should be of 3600lm ANSI Brightness or more Resolution 1280 x 800 or better Should have HDMI x2, VGA x1, Composite x1, USB x1 Input ports and VGA Out x1 or more Should have a 10W built-in Speakers or more Aspect Ratio 16:10 Native, 16:9/4:3 Compatible Horizontal Scan Rate 15.3 - 91.1kHz Vertical Scan Rate 24 - 85Hz (120Hz for 3D) Contrast Ratio 20000:1,Keystone Correction ± 40° Vertical Makes: Benq,Optoma ,Hitachi

1

-

-

... More
SITC of Ceiling Mount for projector having minimum following specifications: It should be 1.5'x1.5' stand mount for projector or better Makes: Chief/Btech/Lumi Mounts or equivalent

1

-

-

... More
SITC of Cable Manager having minimum following specifications: It should have Access Enclosure for AV Connectivity It should have Multi-Region Power Socket x2 or more Should have HDMI x1, VGA x1, 3.5mm x1 and LAN x1 Connections or more Should have metal enclosure or better Should be compatible for a table thickness of 0.5" to 2.5" or more Makes: Extron/Crestron/AMX

1

-

-

... More
SITC of Wireless Presentation Gateway having minimum following specifications: It should have Dual WiFi Bands (2.4GHz and 5GHz) or better. It should support up to 64 Devices or more Should have HDMI x1, VGA & Audio x1 Output, RJ45 x1 and USB2.0 x3 Inputs or more Should have iOS AirPlay Mirroring. Should be able to projector 4 devices simultaneously Makes: Newline/InFocus/Barco

1

-

-

... More
SITC of two-way 5.25" Powered Speakers set having minimum following specifications: It should have 5.25" Woofer size and 1" Tweeter size or better It should have 1 active and 1 passive loudspeaker or more Should have low impedance dynamic power of 2x30W or more Should have max SPL @1m 101dB or more. Should be IP 40 Rated or better Should have frequency response of 45Hz to 20KHz. Should have vertical and horizontal dispersion angle of 180 degree @1000Hz Makes: Apart Audio/Aimline/Tannoy

1

-

-

... More
Director Room

-

-

-

... More
SITC of 55" Full HD LED Display having minimum following specifications: Display should be 55" Full HD or Better Should have HDMI x1, VGA&Audio x1, Component(RCa) x1, DVI-D x1 or more input ports It should have Brightness of 350 cd/sqm Should have 10W x 2 Speakers for good audio or more Should have typical contrast ratio of 1200:1 or better Should be have built-in LAN ports and SmartCMS to push content from network Makes: Newline/Samsung/Philips

1

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

1

-

-

... More
SITC of Wireless Presentation Gateway having minimum following specifications: It should have Dual WiFi Bands (2.4GHz and 5GHz) or better. It should support up to 64 Devices or more Should have HDMI x1, VGA & Audio x1 Output, RJ45 x1 and USB2.0 x3 Inputs or more Should have iOS AirPlay Mirroring. Should be able to projector 4 devices simultaneously Makes: Newline/InFocus/Barco

1

-

-

... More
Jt. Director Room

-

-

-

... More
SITC of 55" Full HD LED Display having minimum following specifications: Display should be 55" Full HD or Better Should have HDMI x1, VGA&Audio x1, Component(RCa) x1, DVI-D x1 or more input ports It should have Brightness of 350 cd/sqm Should have 10W x 2 Speakers for good audio or more Should have typical contrast ratio of 1200:1 or better Should be have built-in LAN ports and SmartCMS to push content from network Makes: Newline/Samsung/Philips

1

-

-

... More
SITC of Display Wall Mount Wall Mount should be able to support IFPD's from 55" to 65" Makes: Chief/Lumi/Btech Mounts

1

-

-

... More
SITC of Wireless Presentation Gateway having minimum following specifications: It should have Dual WiFi Bands (2.4GHz and 5GHz) or better. It should support up to 64 Devices or more Should have HDMI x1, VGA & Audio x1 Output, RJ45 x1 and USB2.0 x3 Inputs or more Should have iOS AirPlay Mirroring. Should be able to projector 4 devices simultaneously Makes: Newline/InFocus/Barco

1

-

-

... More
KITCHEN EQUIPMENTS

-

-

-

... More
Supply Installation and Commissioning the following Equipment, manufactured in India using SS 304 sheets as per manufacturer's specifications. Manufacturing specifications to be got approved by the Engineer in Charge for finalization. For all Electrical Kitchen Equipments as per details below, detailed specifications shall have to be provided for approval from the Engineer in Charge.

-

-

-

... More
TABLE COUNTERS

-

-

-

... More
Table Counter (48"X24"X34")

13

-

-

... More
Table Counter (24"X24"X34")

2

-

-

... More
Table Counter (72"X24"X34")

3

-

-

... More
Counter with Single Burner (24"X24"X34")

8

-

-

... More
Counter with Two Burner Range (48"X24"X34")

2

-

-

... More
Counter with Two Sink Unit (20"X34"X34")

2

-

-

... More
Counter with Three Sink Unit (60"X24"X34")

1

-

-

... More
Work Table with sink (60"x24"x34")

2

-

-

... More
Work Table with sink (48"x24"x34")

5

-

-

... More
Work Table (48"X24"X34") with OHS (43"X17"X34")

3

-

-

... More
Soil Dish Landing Table (48"x24"x34")

2

-

-

... More
STORAGE

-

-

-

... More
Pot Rack (51"x24"x72")

4

-

-

... More
Pot Wash (125"X56"X34")

2

-

-

... More
SS Rack (48"x24"x72")

3

-

-

... More
Plate Rack (60"X12"X24")

2

-

-

... More
Rack (39"X24"X72")

2

-

-

... More
Lockers (72"X24"X72")

3

-

-

... More
Gunny Bag Stand (72"X24"X34")

2

-

-

-

-

-

... More
Exhaust hood (96"X36"X20")

2

-

-

... More
EQUIPMENTS

-

-

-

... More
Stock Pot Stove (24"X24"X20")

2

-

-

... More
Vegetable processer (STANDARD)

2

-

-

... More
Tilting Frying Pan (42"X30"X20")

2

-

-

... More
Rice Boiler Machine (42"X30"X20")

2

-

-

... More
Chapati Plate with Puffer (60"x24"x34")

2

-

-

... More
Hot Plate (60"x24"x34")

2

-

-

... More
IDLY Steamer (54 IDLIES)

2

-

-

... More
Potato Peeler (STANDARD)

2

-

-

... More
Gravy Machine (STANDARD)

2

-

-

... More
Bain Marie (72"X24"X34")

6

-

-

... More
Tea & Coffee Machine (STANDARD)

2

-

-

... More
Juicer (STANDARD)

2

-

-

... More
Ice Cream Freezer (48"x24"x34")

2

-

-

... More
Dough Kneeder (25kg)

2

-

-

... More
Wet Masala Grinder (10kg)

2

-

-

... More
Single Deck Oven (STANDARD)

2

-

-

... More
Microwave Oven (23.9"X19.2"X13.6")

2

-

-

... More
Soup tourner/warmer (19lt)

2

-

-

... More
Double door Refrigerator (30"X30"X84")

2

-

-

... More
Dish Washer (48"x24"x34")

3

-

-

... More
Display Refrigerator (60"X24"X51")

2

-

-

... More
Pre Rinse Jet Spray

2

-

-

... More
Weighing Scale

2

-

-

... More
LAUNDRY EQUIPMENT

-

-

-

... More
Supply Installation and Commissioning the following Equipment-Indian / Imported as per manufacturer's specifications. Manufacturing specifications to be got approved by the Engineer in Charge for finalization. For all Electrical Laundry Equipments as per details below, detailed specifications shall have to be provided for approval from the Engineer in Charge

-

-

-

... More
Washing Machine 23Kg. Cap.

-

-

-

... More
TOP LOADING, Outer body & Inner Basket Stainless Steel, elec. Heated,Front-Loading, Auto-Reverse, Auto-Timed, Auto-Temp. Control fitted with control-panel & 3HP-3phase motor etc with built in hydro extractor

2

-

-

... More
Drying Tumbler 35Kg. Cap.

-

-

-

... More
Outer M. S, Inner Basket of Stainless Steel,Elect. Heated, Auto-Reverse, Auto-Timed,Auto-Temp. Control with Control-Panel 1HP-3Phase 2Motors etc.

2

-

-

... More
Vacuum Table with boiler                               

-

-

-

... More
Table size:1200x750,Silicon padding, Strong welded construction thermo statically control stainless steel Table with Steam Iron (Imported)

2

-

-

... More
Flat Bed Press

-

-

-

... More
Pneumatically Operated, Fitted with Blower Control Panel.

1

-

-

... More
COMPOSTER

-

-

-

... More
Supply, Installation, Testing and Commissioning of Electrically operated fully automatic Composting machine for converting Organic / Food waste to compost having a capacity of upto 75kgs per day with inbuilt shredder. Detailed specifications shall have to be provided for approval from the Engineer in Charge

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.