Odisha Mining Corporation Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Mining Corporation Limited - OMC Tender

Civil And Construction
Building Construction
Eprocure
Opening Date7 Feb 2023
Closing DateCancelled
Tender Amount₹ 3,47,69,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
C.C of prop. (1:4:8) in foundation using 40mm. Size broken hard granite metal of approved quality from approved quarry including lowering,laying concrete to required levels laid in layers not exceeding 150mm thick including cost,conveyance,royalities of all materials,cost of all labour,T & P required for the work etc.required to complete as per direction of EIC.

3.61

-

4510.6

... More
Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge

11.58

-

172.1

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Foundation

5.08

-

5544.57

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Column Ground floor

2.38

-

11427.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Tie beam Ground floor

2.89

-

5910.3

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Roof beam Ground floor

3.77

-

11427.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Roof slab Ground floor

3.15

-

9776.52

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Platform slab Ground floor

0.89

-

5873.23

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Lintel Ground floor

1.35

-

9173.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Sill Ground floor

0.72

-

9173.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Column First floor

1.35

-

12473.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Roof beam First floor

5.31

-

12473.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Roof slab (First floor)

16.91

-

10423.4

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Lintel (First floor)

0.81

-

9671.4

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Sill (First floor)

0.54

-

9671.4

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Platform slab (First floor)

0.99

-

6022.35

... More
Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost,conveyance of HYSD bars Fe500 and binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) in Foundation & Ground floor

30.96

-

10006.39

... More
Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost,conveyance of HYSD bars Fe500 and binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) in First floor

32.62

-

10031

... More
Fly ash brick masonry in C.M.(1:6) with the bricks of 25Cm x 12Cm x 8cm size having crushing strength not less than 75 Kg/Cm2 in super structure, ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC. Ground floor

1.18

-

4485.85

... More
Fly ash brick masonry in C.M.(1:6) with the bricks of 25Cm x 12Cm x 8cm size having crushing strength not less than 75 Kg/Cm2 in super structure, ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC. First floor

2.27

-

4761.66

... More
Fly ash brick masonry in C.M.(1:6) with the bricks of 25Cm x 12Cm x 8cm size having crushing strength not less than 75 Kg/Cm2 in super structure, ornamental molding and other similar type of works with all necessary projections, splays corbelling, cutting, champering, including cost conveyance, royalties of all materials, cost of all labour, T&P required for the work etc. compl. in all respect as per direction of EIC. Terrace floor

5.81

-

5078.83

... More
Providing & Applying priming coat with water bound wall Cement primer of approved brand and manufacture and of approved quality and shade on plastered surface of wall ncluding cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. Ground floor

1874.33

-

60.6

... More
Providing & Applying priming coat with water bound wall Cement primer of approved brand and manufacture and of approved quality and shade on plastered surface of wall ncluding cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. First floor

1879.59

-

62.1

... More
Providing & Applying priming coat with water bound wall Cement primer of approved brand and manufacture and of approved quality and shade on plastered surface of wall ncluding cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. Terrace floor (2nd floor)

68.37

-

63.7

... More
12mm (1/2") thick cement plaster (1:6) for finished smooth to masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC Ground floor

24.17

-

144.9

... More
12mm (1/2") thick cement plaster (1:6) for finished smooth to masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC First floor

23.22

-

150.6

... More
12mm (1/2") thick cement plaster (1:6) for finished smooth to masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC Terrace floor (2nd floor)

37.41

-

156.6

... More
16mm (5/8") thick cement plaster with (1:6) for finished smooth to inside surface of brick walls in all floors racking out the joints including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. Ground floor

24.47

-

206.8

... More
16mm (5/8") thick cement plaster with (1:6) for finished smooth to inside surface of brick walls in all floors racking out the joints including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. First floor

23.52

-

211.9

... More
16mm (5/8") thick cement plaster with (1:6) for finished smooth to inside surface of brick walls in all floors racking out the joints including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. Terrace floor (2nd floor)

30.96

-

217.1

... More
6mm thick cement plaster (1:4) to RCC surfaces including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. Ground floor

67.69

-

160.8

... More
6mm thick cement plaster (1:4) to RCC surfaces including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC. First floor

98.48

-

164.8

... More
Finishing wall surface of walls with Acrylic wall putty (Cement based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, cost of all labour T&P etc. complete as per direction of EIC. (Make SG England/ J.K./Birla) Ground floor

1380.09

-

86.7

... More
Finishing wall surface of walls with Acrylic wall putty (Cement based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, cost of all labour T&P etc. complete as per direction of EIC. (Make SG England/ J.K./Birla) First floor

1382.27

-

88.1

... More
Painting two coats with plastic emulsion paint of approved brand and shade to surface of wall to give an even shade including washing the surface with cost of brush, scaffolding, staging charges with cost of all materials, cost of all labour, T&P etc required complete as directed by EIC. (Plastic emulsion should be of ICI/ Berger / Asian make) Ground floor

1409.97

-

79

... More
Painting two coats with plastic emulsion paint of approved brand and shade to surface of wall to give an even shade including washing the surface with cost of brush, scaffolding, staging charges with cost of all materials, cost of all labour, T&P etc required complete as directed by EIC. (Plastic emulsion should be of ICI/ Berger / Asian make) First floor

1412.28

-

80.6

... More
Painting two coats with plastic emulsion paint of approved brand and shade to surface of wall to give an even shade including washing the surface with cost of brush, scaffolding, staging charges with cost of all materials, cost of all labour, T&P etc required complete as directed by EIC. (Plastic emulsion should be of ICI/ Berger / Asian make) Terrace floor

52.23

-

82.3

... More
Weather coat two coats of approved brand and shade over a coat of primer over exterior surface of wall exposed to weather including cost of brush, scaffolding, staging charges with cost, conveyance of all materials, cost of all labour, T&P etc. complete as directed by EIC. (Weather coat should of ICI/Berger/Asian is to be used). Ground floor

288.27

-

62.3

... More
Weather coat two coats of approved brand and shade over a coat of primer over exterior surface of wall exposed to weather including cost of brush, scaffolding, staging charges with cost, conveyance of all materials, cost of all labour, T&P etc. complete as directed by EIC. (Weather coat should of ICI/Berger/Asian is to be used). First floor

291.03

-

63.5

... More
Weather coat two coats of approved brand and shade over a coat of primer over exterior surface of wall exposed to weather including cost of brush, scaffolding, staging charges with cost, conveyance of all materials, cost of all labour, T&P etc. complete as directed by EIC. (Weather coat should of ICI/Berger/Asian is to be used). Terrace floor

80.73

-

64.8

... More
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm of approved quality and approved shade in all floors at all height by making the surface of wall smooth including cost, coveyance, loading and unloading and of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. Ground floor

192.18

-

267.24

... More
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm of approved quality and approved shade in all floors at all height by making the surface of wall smooth including cost, coveyance, loading and unloading and of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. First floor

194.02

-

267.24

... More
Providing & fixing of jointing compound for old concrete & new concrete :Surface preparation: Surface must be sound, dry, clean and free from laitance, ice, standing water, grease, oils, old surfacetreatments or coatings and all loosely adhering particles to achieve a laitance and contaminant free,open textured surface. Cement laitance must be removed and the surface to be treated must be mechanically roughened. Mixing: The mixing process must be done only after the surfacepreparation. Sikadur®-32 LP (which provides a bond of far greater strength than the tensile strength of the concrete itself.) components already have the appropriate mixing ratio. The mixing could be done with low speed electrical mixer (600 rpm) with helical blades for 3 minutes, until the mixture becomes homogeneous gray colour without lumps. Apply the mixed Sikadur®-32 LP to the prepared surface by brush, roller, spray or with a trowel, and ensure uniform and complete coverage. On hardened concrete substrates mechanically prepared to receive fresh concrete, always apply by brush and work the material well into the substrate. Place the fresh concrete whilst the Sikadur®-32 LP layer is still ‘tacky’. If the material becomes glossy and loses tackiness, apply a fresh coat with additional Sikadur®-32 LP and proceed. All complete as per manufactures specification & in the diretion of The Engg-In- Charge.

3.3

-

575

... More
Providing and laying grading concrete 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. Above newly constructed roof Terrace floor (First floor roof)

712

-

336.2

... More
Coving & Pipe penetration: Providing & making of coving of atleast 150 mm to the either side of the roof mother slab & Parapet junction with Sika Latex polymer modified Cement sand mortar @ 1: 3 (1 Part Cement: 3 part Sand) by weight over a freshly laid cement slurry dmixed with Sika latex @ 1 : 4 : 6 ( 1 part Sika latex: 4 part water; 6 part Cement) & leave it for proper water curing at least 7 days. Pipe Penetration: Fiiling the gap between the PVC membrane & concrete with Non shrink Micrococoncrete SikaRep Microcrete 4 followed by Supply and apply of solvent free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The putty shall be applied to a thickness of minimum 20mm on pipe penetration joint to concrete. Product: Sikagard®-694 F (I) Yield: 0.6 ltr/kg. Product requirements: suitable for submerged condition; compressive strength of 40 N/mm2 (1 day) according to IS 9162-197. Waterponding Test to be carried out for a period of 48 hrs keeping water of 2 inches prior to installation of waterproofing system. If any leakage found then the same the same should be rectfied by proper injection methodology. Cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc. Any surface cracks shall be chased open into a ‘V’ groove, and filled with Sika Latex modified cementitious mortar.Providing and applying a glass fibre reinforced elastic, acrylic – cementitious coating system over the prepared substrate. Base coat: SikaTop® Seal-109 hi. Consumption base coat: 1 kg/m2.Reinforcement: Sika® Fab-1.Top coat: SikaTop® Seal-109 hi. Consumption top coat: 1.2 kg/m2.The waterproofing membrane should be terminated at 300mm from the final finished level by making a grove of 10mmx 10mm and then inserting the membrane inside the grove followed by sealing of the same with Sika latex modified Cement sand mortar or by Sika Polysulphide sealant. System requirements: conforms to IS 2645, IS 101;elongation at break: 35 %; slant shear bond strength: approx. 4 N/mm2 as per FIP 5.15; water permeability passes as per IS 2645; weather resistance as per IS 101. All complete as per manufactures specification & in the diretion of The Engg-In- Charge (Existing roof)

712

-

700

... More
Coving & Pipe penetration: Providing & making of coving of atleast 150 mm to the either side of the roof mother slab & Parapet junction with Sika Latex polymer modified Cement sand mortar @ 1: 3 (1 Part Cement: 3 part Sand) by weight over a freshly laid cement slurry dmixed with Sika latex @ 1 : 4 : 6 ( 1 part Sika latex: 4 part water; 6 part Cement) & leave it for proper water curing at least 7 days. Pipe Penetration: Fiiling the gap between the PVC membrane & concrete with Non shrink Micrococoncrete SikaRep Microcrete 4 followed by Supply and apply of solvent free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The putty shall be applied to a thickness of minimum 20mm on pipe penetration joint to concreteProduct: Sikagard®-694 F (I) Yield: 0.6 ltr/kg. Product requirements: suitable for submerged condition; compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979. Waterponding Test to be carried out for a period of 48 hrs keeping water of 2 inches prior to installation of waterproofing system. If any leakage found then the same the same should be rectfied by proper injection methodology. Cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc. Any surface cracks shall be chased open into a ‘V’ groove, and filled with Sika Latex modified cementitious mortar. Providing and applying two coats of Sika Topseal 107. coloured, 2-pack acrylic-cementitious waterproofing coating system reinforced with Sika Fab1 ( glass fibre) Base coat: SikaTop® Seal-107 @ 1.5 Kg/sqm. Reinforcement: Sika® Fab-1. Top coat: SikaTop® Seal-107 @ 1.5 Kg/sqm.Total Consumption of Sikatop seal 107 : 3 kg/m2. System requirements: Conforms to IS 2645,IS 101. Elongation at break: 40 %; slant shear bond strength: approx. 4N/mm2as per FIP 5.15; water permeability passes as per IS 2645; weather resistance as per IS 101. The waterproofing membrane should be terminated at 300mm from the final finished level by making a grove of 10mmx 10mm and then inserting the membrane inside the grove followed by sealing of the same with Sika latex modified Cement sand mortar or by Sika Polysulphide sealant. All complete as per manufactures specification & in the direction of The Engg-In- Charge Ground floor

145.02

-

650

... More
Coving & Pipe penetration: Providing & making of coving of atleast 150 mm to the either side of the roof mother slab & Parapet junction with Sika Latex polymer modified Cement sand mortar @ 1: 3 (1 Part Cement: 3 part Sand) by weight over a freshly laid cement slurry dmixed with Sika latex @ 1 : 4 : 6 ( 1 part Sika latex: 4 part water; 6 part Cement) & leave it for proper water curing at least 7 days. Pipe Penetration: Fiiling the gap between the PVC membrane & concrete with Non shrink Micrococoncrete SikaRep Microcrete 4 followed by Supply and apply of solvent free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The putty shall be applied to a thickness of minimum 20mm on pipe penetration joint to concreteProduct: Sikagard®-694 F (I) Yield: 0.6 ltr/kg. Product requirements: suitable for submerged condition; compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979. Waterponding Test to be carried out for a period of 48 hrs keeping water of 2 inches prior to installation of waterproofing system. If any leakage found then the same the same should be rectfied by proper injection methodology. Cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc. Any surface cracks shall be chased open into a ‘V’ groove, and filled with Sika Latex modified cementitious mortar. Providing and applying two coats of Sika Topseal 107. coloured, 2-pack acrylic-cementitious waterproofing coating system reinforced with Sika Fab1 ( glass fibre) Base coat: SikaTop® Seal-107 @ 1.5 Kg/sqm. Reinforcement: Sika® Fab-1. Top coat: SikaTop® Seal-107 @ 1.5 Kg/sqm.Total Consumption of Sikatop seal 107 : 3 kg/m2. System requirements: Conforms to IS 2645,IS 101. Elongation at break: 40 %; slant shear bond strength: approx. 4N/mm2as per FIP 5.15; water permeability passes as per IS 2645; weather resistance as per IS 101. The waterproofing membrane should be terminated at 300mm from the final finished level by making a grove of 10mmx 10mm and then inserting the membrane inside the grove followed by sealing of the same with Sika latex modified Cement sand mortar or by Sika Polysulphide sealant. All complete as per manufactures specification & in the direction of The Engg-In- Charge First floor

169.91

-

650

... More
Supplying all materials, labour, T&P and fixing Matt finished vitrified floor tile of 1200mmx600mm size of approved brand and shade on 20mm thick cement mortar (1:4) (1 cement:4 sand)jointed with neat cement, slurry mixed with pigment to match the shed of tiles complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work. (Tiles should be of Kajari/ Somany/ RAK / Johnson/Nitco/Pavit/Orient Bell).. First floor

88.72

-

1078.4

... More
Supplying, fitting & fixing of matt finished Vitrified tiles in wall of size 1200mmx 600mm in dadoes, skirting and risers of steps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge First floor (Tiles should be of Kajari/ Somany/ RAK / Johnson/Nitco/Pavit/Orient Bell).

4.05

-

1162.4

... More
Fixing granite slab(Above 0.40 Sqm) (20mm thick) in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royalty of all material, cost of all labour T&P etc. complete as per direction of EIC. Ground floor

5.46

-

2033.2

... More
Fixing granite slab(Above 0.40 Sqm) (20mm thick) in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost, carriage, royalty of all material, cost of all labour T&P etc. complete as per direction of EIC. First floor

8.08

-

2043.3

... More
Providing Granite stone prepolished 10 mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. Ground floor

4.44

-

1543.08

... More
Providing Granite stone prepolished 10 mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. First floor

7.52

-

1558.48

... More
Providing and fixing 1st quality ceramic glazed wall tiles 300mmx200mm /300mmx600mm /600mmx600mm /300mmx450mmconforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades of any size as approved by Engineer- in- charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC.(Tile should be of Somany / RAK / Kajaria /Johnson/Nitco/Pavit/Orient Bell).Ground floor

118.84

-

802.7

... More
Providing and fixing 1st quality ceramic glazed wall tiles 300mmx200mm /300mmx600mm /600mmx600mm/300 mmx450mm conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades of any size as approved by Engineer- in- charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC.(Tile should be of Somany / RAK / Kajaria/Johnson/Nitco/Pavit/Orient Bell ) First floor

174.8

-

817.9

... More
Supplying all materials, labour, T&P and fixing antiskid ceramic floor tile of 600mmx600mm size of approved brand and shade on 20mm thick cement mortar (1:4) (1 cement:4 sand)jointed with neat cement, slurry mixed with pigment to match the shed of tiles complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work.(Tiles should be of Somany / RAK/ Kajaria/Johnson/Nitco/Pavit/Orient Bell ).

-

-

-

... More
Ground floor

35.35

-

696.9

... More
First floor

53.14

-

707

... More
Supply & installation of 100% commercial grade nylon carpet tile of 500x500mm of solution dyed nylon 6 ( AquafilEconyl) quality or equivalent, manufactured in Japan (No Chinese product), Machine Gauge 1/10” or more and having backing of glass fiber + PVC and made of basic fabric of Nonwoven Polyester , total height of 7 mm or more, smoke density( ASTM E 662) less than 450, anti static less than 1.0kv (JIS-L4406 STROLL 23 C. degree 25%R.H.), electrostatic propensity – maximum average 0.5kv (AATCC 134) Color fastness to light- rating 5.0= No change (AATCC 16) critical radiant flux –( ASTM E 648) Class 1 average CRF 0.48 / cm2 or higher certified It is absolutely mandatory that the manufacturer has valid certifications of CRI PLUS certified, GLP 8200, certified from Singapore Green Building Council , certified of Japanese industrial standard (JIS) Mark complete as per specification and direction of EIC including cost, carriage of all materials cost of all labour, T&P required to complete the work( Make:Sapporo/Samurai or equivalent)

-

-

-

... More
First floor

88.72

-

3530.68

... More
Providing and fixing factory made 2 track 2 panel uPVC white colour sliding window comprising of uPVC multi-chambered frame having section Frame 60mm x 55mm, Window sash: 42mm x 66mm, made out of lead free green profiles with corners fusion welded, fully reinforced with Galvanized steel 1.5/2.0 mm. The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size. The sash will be fitted with 5mm Clear Float glass ( Toughen ). MAKE LIST - WINPLUS+, FENESTA

-

-

-

... More
Ground floor

44.1

-

6398

... More
First floor

41.81

-

6398

... More
Terrace floor

1.67

-

6398

... More
Supplying, fitting and fixing of M.S window grills of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc.(as per I.S. specification and as per approved drawings) including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite sTonnese chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in Charge.

-

-

-

... More
Ground floor

1473.05

-

140.7

... More
First floor

1156.61

-

140.7

... More
Terrace flor

41.81

-

140.7

... More
Providing and painting two coats with synthetic enamel paint over a coat of zinc oxide primer of approved quality and approved shade confirmingto ISI on steel work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloadingof all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge.

-

-

-

... More
Ground floor

29.46

-

151.5

... More
First floor

23.13

-

154.6

... More
Terrace floor

0.84

-

157.9

... More
Providing and fixing factory made Louvered uPVC white colour ventilator comprising of uPVC multi-chambered frame having section frame 60mm x 58mm, made out of lead free green profiles with corners fusion welded, fully reinforced with Galvanized steel 1.5/2.0 mm. The profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The ventilator comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size. The sash will be fitted with 5mm Frosted glass . MAKE LIST - WINPLUS+, FENESTA

-

-

-

... More
Ground floor

4.41

-

6033

... More
First floor

4.46

-

6033

... More
Providing and fixing Automatic Sliding door of approved make and design to meet ANSI/BHSM 156.10 standards and based on the product category rules :IBU: PCR automatic doors, automatic gates and revolving door sysytem, PCR tested. The CE marking for the product takes into account the proof of conformity with harmonizes norms: EN 16005:2012/AC:2015: Power operated pedestrain doorsets- safety in use- requirement and test methods, EN 61000-6-2:2005: Electromagnetic compatibility,EN 61000-6-3, EN60335-1, EN ISO 1849, EN 16005, IEC 60335-1, IEC 60335-2-103, UL 325, DIN 18650Environmental product declaration in accordance with ISO 14025 and EN 15804. Tested for Durability of 1 Million Cycles, for frameless glass door application, modular design including internal cover. 12 mm clear toughened glass for 1/ 2 Nos sliding door panel as per drawings, Operator to be mounted on MS-Box Section/Equalant.Operator Finish should be Silver Anodised E6/C0, with operator dimensions Maximum (H x D) : 123x150 mm and of length as required to suit the opening size given below. The track profile should be separate from the main profile for enabling reduction in vibration insulation and easy maintainence. Microprocessor-controlled control unit, Self-learning. Maximum power consumption of 250W.Power Supply100-240V AC/ -+ 10%/50/60 Hz. Auxilary voltage of 24V DC, min. 1000mA Clear opening (length and width as per drawings). Door weight single 240kg Door weight bi-parting door 2 x 200kg Opening and closing force Friction related, adjustable from 30 to 190N Height x Depth150mm (H) x 123mm (D). Opening and closing speed single 0.85m/sec (depends on perf. Level). Opening and closing speed, bi-part 0.85m/sec (depends on perf. Level). Hold open time 0 to 60 sec.

-

-

-

... More
Ambient Temperature -20 °C to +50 °C. Humidity max 85%. Class of protection(dust). IP 20 EPD-Declaration available convenience mode (battery-powered) 24V battery (optional). 3 different performance level (Standard, High & Exceptional). Easy performance upgrade possibility (when the use of building change).Operation "mode selector with service indication diode". Combination of dual mode selectors. Maximum distance between mode selector and door system (500 metre). Interlock system,Synchronisation, Partial close function (auto airing) ,Auto width ,Prolonging of hold open time, Opening delay (adjustable delay to ensure that the lock "unlock") open/close time-out (when close impulse is forgotten the door will close by timeout it selves).Nurse function (adjustable opening width depending on the need). Safe performance (ensure safety even without extra safety devices). Status relay output (configurable output on customer needs: doorbell, air curtain, door location) Rates shall include all items as listed above, glass, approved all weather silicon sealants with baker rod (if required), sizes as indicated in the drawings, tools, plants, wastages, preparation and submission of shop drawings for approval, scaffolding, hardware etc all complete as per drawings and as directed by the Engineer-in-charge

5.5

-

22652.4

... More
Providing, fitting and fixing of 32mm thick flush door with/without vision panel with both side laminated as per the specification complete with all materials, inclusive of all hardware material, hinges, nails, screws, doorknobs, handles, topper etc. including the cost of all materials, labour and T&P and overheads etc. complete. The exposed wood work shall be finished with automotive paint. two coats with primer. The rates also includes the cost of 40 x 25mm wooden beading for the partition in front of the door and finished with automotive paints and as per direction of EIC.

-

-

-

... More
Ground floor

4.55

-

9983

... More
First floor

11.71

-

9983

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, door handle, lock, stopper etc all complete as per direction of Engineer-in-charge including cost, coveyance, loading and unloading and of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. (Make-door of DORMA XL-C PACKAGE xl-c 4001B and saint gobain glass or equivalent)

-

-

-

... More
Ground floor

17.23

-

20875

... More
First floor

18.86

-

20875

... More
Providing and fixing in position WPC frames of size 150mmx65mm to doors fixed with MS hold fast of 35x5mm embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded sTonnese aggregate 20mm nominal size) complete with all materials, labours, T & P including cost, conveyance, loading, sundries required for the work etc. complete in all respect as directed by the Engineer-in-charge

-

-

-

... More
Ground floor

20.73

-

2724

... More
First floor

25.91

-

2724

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.

-

-

-

... More
Ground floor

7.8

-

5490

... More
First floor

9.76

-

5490

... More
Panelling for Door frame by fixing 12mm BWR ply over plastered wall surface in all 3 faces with the help of screw fasteners, adhesive over with 1mm thick laminate fixed by means of adhesive having grooves. The face of the panel & edge moulding shall be finished properly. The cost includes all the materials, labour, transportaion , taxes etc. complete as per the direction of EIC. (Make:Greenply or equivelent)

-

-

-

... More
Ground floor

20.73

-

1500

... More
First floor

15.55

-

1500

... More
Providing and fixing High Pressure Laminate(HPL) cladding work (6mm thick) of Exterior Grade compact laminate height upto 10m. on walls of approved colour and size to be fabricated/screwed with 2mm thick aluminium tube channel with the help of rivets, anchor fasteners, including cost of all materials, labour , T&P ,scafolding etc all required to complete the work as per Architectural drawings and direction of EIC.(Make:Greenlam or equivalent)

148.06

-

6674

... More
Providing and fixing High Pressure Laminate(HPL) cladding work (6mm thick) of Interior Grade compact laminate height upto 3m. of approved colour and size to be fixed/screwed with 2mm thick aluminium tube channel with the help of rivets, anchor fasteners etc. including cost of all materials, labour , T&P ,scafolding etc all required to complete the work as per Architectural drawings and direction of EIC..(Make:Greenlam or equivalent)

68.73

-

5597

... More
Designing, Fabricating, and Installing Semi‐unitized structural Glazing Fixed panels with Aluminium frame works made from Special system sections from Jindal make confirming to 6063‐T5/T6 alloy with Vertical Mullions and horizontal Transoms sections and Louvers (Jindal Make) as per design intent in the Glazing frames to be connected to each other by means of Angle cleats and angle brackets. The Mullions if required shall be provisioned with splices to prepare a continuous Section to support the glass panes. The whole frame is connected to the building or its opening by means of HDG brackets and specialty anchors designed to withstand the desired wind pressure from 1-2 Kpa. The single glass as provisioned with 6 mm Reflective soft coated toughened glass (MAKE :Saint Gobain) to be framed with subframes of the series system sections by DC995 structural silicones to a desired surface width with the remaining widths to be covered by spacer tapes. The glass panels and louver with 6mm Reflective soft coated toughened glass and frames are fixed to the base framework with special cleats/toggles sections of the series. The aluminum sections shall be anodized to 15 micrometer thickness to a desired finish, equipped with provisions for EPDM gaskets, provisions to striking out joints by weathering silicon sealants of McCoy or Dow corning make with labour, material, T&P etc all required to complete the work as per direction of EIC.

30.55

-

9975

... More
Providing & fixing of 4mm MS sheet with paint finish supported by required member including consumables, labour charges, materials etc all complete as per direction of EIC.

33.13

-

6000

... More
Providing and fixing of 12.5mm Gypsum board false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.45 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.75 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.45 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 100 mm on both sides of joint and , all complete as per drawings, specification and direction of the Engineer in Charge.

-

-

-

... More
Ground floor

215.85

-

880

... More
First floor

212.54

-

880

... More
Providing & fixing of 8 mm thick fully perforated calcium silicate board false ceiling made with calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/ sq. cm, of size 595X595 mm, having perforation of dia. 10 mm with minimum perforated area 18% with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick Rockwool of 48 kg/cum backing. 595x595 mm in true horixontal level, suspended on interlock metal grid of hot dipped galvanized steel sections(galvanized @ 120 grams/sqm, both inclusive) consisting of main "T" running with suitably spaced joints to get required length and of size 24X38 mm made from 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200X600 mm and and secondary cross "T" of length 600mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and well angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fastners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all completefor all heights as per specifications, drawings and as directed by Engineer-in-Charge.

-

-

-

... More
Ground floor

503.66

-

1350

... More
First floor

495.92

-

1350

... More
Providing and fixing 12mm thick compact High Pressure Laminate (HPL) Urinal partition, 1195 mm height , 450 mm Depth including Stainless steel L clamp which is to be used to attach the divider to the wall, stainless steel L clamp hardware fittings along with Su 304 screws are used to fix the Urinal partitions on the wall. All fittings and hardware all complete of approved make as per drawing and design all complete as per direction of EIC.(Make:Greenlam or equivalent)

-

-

-

... More
Ground floor

4

-

5200

... More
First floor

4

-

5200

... More
Providing and fixing Toilet cubical (Classique-Versatile model of following standard dimension which includes 600mm door size width) made up of thermosetting resign treated high pressure ,self supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing . Compact board should be resistance to water immersion through permissible increase on thickness and mass 0.60% and board density 1.35kg/cm3 and fulfilled the criteria of FSC and green guard gold certification and manufactured under EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/97 and EN:438-6 and cleassification of BS1D0 standard. Pilaster to be supported with SS (grade316) adjustable foot and intermediate panels will attached to the wall with the help of approved aluminium channels and all required hardware, made up of stainless steel as per manufacturer’s specification and instruction of Engineer-in-charge like Door knob, gravity hinges,Thumb turn locksets with occupancy indicators ,coat hooks with door stoper , U channel, top rail with corner connector, adjustable foot/pedestal,Rubber noice deafening tape, screw & wall plugs. The top fitting should consist of anodized aluminium metal top rail(as per manufacturer specification) which will directly get fixed with pilaster ,Aluminium corner bend (connected with top rail ) will be use in corner of cubical in absence of brick wall, Aluminium wall fixing is used only on the wall which will hold the top rail. All screw will of 304 grade in SS with stain finish. Pilaster shoud be raised from the the floor with a clearance height upto 150 mm with the help of adjustable leg.Finish and colour of Toilet cubical should be approved under guidance of engineer-in-charge. (Make: GREENLAM or Equivalent),1.01-  Toilet cubical with standard dimension of 1995mm(H)x1000mm(W)x1500mm(Depth), which includes 600mm door size width or as per drawing.1.02-  Toilet cubical I- shape(front partition)with standard dimension of 1995mm(H)x1000mm (W) which includes door size width or as per drawing.

-

-

-

... More
Ground floor

5

-

32700

... More
First floor

7

-

32700

... More
Providing and fixing in position cabin Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Cabin. Table (6'-6"x2'-6"x2'-6") Side Unit (3'-6"x1'-6"x2'-6") (Make:Greenply or equivalent)

16

-

37837.91

... More
Providing and fixing in position cabin Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Cabin. Table (5'-0"x2'-0"x2'-6") Side Unit (3'-0"x1'-6"x2'-6") (Make:Greenply or equivalent)

7

-

29130.47

... More
Providing and fixing in position cabin Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Cabin. Table (5'-6"x2'-6"x2'-6") Side Unit (3'-0"x1'-6"x2'-6") (Make:Greenply or equivalent)

2

-

29130.47

... More
Providing and fixing in position cabin Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Cabin. Table (7'-0"x3'-0"x2'-6") Side Credenza(3'-0"x1'-6"x2'-6") (Make:Greenply or equivalent)

1

-

37837.91

... More
Providing and fixing in position cabin Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Cabin table (5'-0" x 2'-0" x 2'-6") Side Credenza(3'-0"x1'-6"x2'-6") (Make:Greenply or equivalent)

14

-

29130.47

... More
Providing and fixing in position cabin Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Cabin table (4'-6" x 2'-0" x 2'-6") Side Credenza(3'-0"x1'-6"x2'-6") (Make:Greenply or equivalent)

1

-

29130.47

... More
Providing and fixing in position PA Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 9 mm thick ply for modesty panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. PA table (5'-0" x 2'-0" x 2'-6") with side credenza (3'-0" x 1'-6" x 2'-6") (Make:Greenply or equivalent)

1

-

27762.18

... More
Providing and fixing in position RM Table with side credenza unit is made out of 19mm thick plywood for top,bottom, side, keyboard tray,leg and 25 mm thick ply for modesty and 9 mm thick ply for horizontal member of side credenza panel and 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. RM table (7'-0" x 3'-0" x 2'-6") with side credenza (3'-0" x 1'-6" x 2'-6") (Make:Greenply or equivalent)

1

-

48054.6

... More
Providing and fixing in position conference table made out of 19mm thick plywood for top,bottom, side,mid, mid modesty panel and 1 mm thick lamination on all surfaces with teak wood beading at edges of table top . Item to be completed as per drawings and design and as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape, telescopic channel of hafley brand etc including wastage complete all as per direction of EIC. Conference table of size (25'-0" x 4'-0" x 2'-6") (Make:Greenply or equivalent)

1

-

144794.2

... More
Providing and fixing in position Mobile pedestal unit made out of 19mm thick plywood for top,bottom, side,front side of both drawer and shutter and 12 mm thick ply for drawer side and base with 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per direction of EIC. The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape,hinges of hafley brand etc including wastage complete all as per direction of EIC. Mobile pedestal unit (1'-4" x 1'-3" x 2'-4") (Make:Greenply or equivalent)

42

-

7723.48

... More
Providing and fixing in position reception table unit made out of frame work of MS square hollow secion (40 mmx40mmx 2mm),MS square hollow secion (25mmx25mmx2mm) and MS angle section section of (25mmx25mmx3mm),MS square hollow secion (25mmx25mmx1.6mm) with fixing of corian marble at top,front and projected top. Shelf made out of 19 mm thick plywood with both side lamination of 1 mm thick . The work to be completed in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape,hinges of hafley brand etc including wastage complete all as per direction of EIC. Reception table (5'-0" x 2'-6" x 2'-6") with Corian top (Make:Greenply or equivalent)

1

-

38975.12

... More
Providing and fixing in position 6 seater linear work station with storage made out of 19mm thick plywood for top,bottom,sides, mid, keybard tray,drawer,shutter and vertical panel for common partiition & 12mm thick ply for drawer side and base with 1 mm thick lamination to all exposed surfaces and 0.8mm thick to all ineer surface. Item to be completed as per drawings and design and as per direction of EIC.Item to included, all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings of godrej brand, fevicol, hinges channels etc., complete all as per direction of EIC.6 seater linear workstation (14'-2" x 6'-0" x 2'-6") (Make:Greenply or equivalent)

8

-

167266.09

... More
Providing and fixing in position half height and full height storage made out of 19mm thick plywood for top,bottom, side, leg , inside horizontal member ,back, inside horizontal members and shutter with 1 mm thick lamination on exposed surface and 0.8 mm thick for inner surface. Item to be completed as per direction of EIC. The work to be completed drawings and design and as per in all respect as per specification and direction of EIC including all types of Hardware,locks, screws, wooden lipping, beading, sliding drawer fittings, fevicol, masking tape,hinges of hafley brand etc including wastage complete all as per direction of EIC. Storage unit (3'-6" x 1'-6" x 4'-0")

1854

-

1304.25

... More
Providing and placing Center table Verve Glass tables (610-FL-DM Center Table) Rectangular Chrome Frame with Glass Top Size 1200 x 600mm complete as per direction of EIC.

5

-

7426

... More
Providing and placing Center table Verve Glass tables (610-FL-DM Center Table) Rectangular Chrome Frame with Glass Top Size 600 x 600mm complete as per direction of EIC.

3

-

5541.6

... More
Providing and placing Indulge: S-906 E (Leatherette / Fabric) With Chromeplated Legs & Frame. 3 Seater: 1800 (W) x 710 (D) x 780 (H) complete as per direction of EIC.

5

-

34950

... More
Site Development works (Main gateway & Boundary wall) Earth work in excavation of foundation treaches in all kinds of soil including moorum, stoney earth and earth mixed with boulders ( except sheet rocks and boulders requiring for blasting) including dressing and levelling the bed up to the required depth and depositing the excavated materials at places away from the work site with all leads and 1ifts, T&P shoring and shuttering and dewatering if required etc. comp. as directed by EIC.

10.27

-

217.6

... More
Filling foundation and plinth with river sand, well watered, rammed including cost, conveyance, royalties of materials, cost of all labour and T&P required for the work etc. complete as per direction of EIC.

0.48

-

583.6

... More
C.C of prop. (1:4:8) in foundation using 40mm. Size broken hard granite metal of approved quality from approved quarry including lowering,laying concrete to required levels laid in layers not exceeding 150mm thick including cost,conveyance,royalities of all materials,cost of all labour,T & P required for the work etc.required to complete as per direction of EIC.

0.48

-

4510.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Footing

1.37

-

5544.57

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in Column

2.02

-

11427.6

... More
R.C.C. work of M-25 having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties & taxes of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills in roof beam

1.09

-

11427.6

... More
Supplying HYSD bars of approved quality size and grade and cutting, bending, binding and tying the grills in proper position as required for the RCC work in all floors, including cost,conveyance of HYSD bars Fe500 and binding wires of 18 to 20 gauge and cost of labour,T & P and other materials complete in all respact as directed by the EIC.

8.39

-

10006.39

... More
6mm thick cement plaster (1:4) to RCC surfaces including watering and curing and cost with cost , carriage of all materials and cost of all labours, T&P required to complete as per direction of EIC.

24.3

-

160.8

... More
Supplying, fitting, fixing of M.S grill in square bar as per approved drawing size and design using structural M.S angle flat, round or square bars with well welded and placing in proper position including all cost, conveyance of all materials, T & P etc. to complete the work in all respect as per direction of EIC. (The design & drawing of grill shall be provided & approved by EIC)

498.49

-

140.7

... More
Providing & Applying priming coat with water bound wall Cement primer of approved brand and manufacture and of approved quality and shade on plastered surface of wall ncluding cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge.

967.12

-

60.6

... More
Weather coat two coats of approved brand and shade over a coat of primer over exterior surface of wall exposed to weather including cost of brush, scaffolding, staging charges with cost, conveyance of all materials, cost of all labour, T&P etc. complete as directed by EIC. (Weather coat should of ICI/Berger/Asian is to be used).

773.69

-

62.3

... More
Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm of approved quality and approved shade in all floors at all height by making the surface of wall smooth including cost, coveyance, loading and unloading and of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge.

188.9

-

267.24

... More
Providing 20mm thick and above 0.40 Square Meters size granite sTonnese cladding of approved quality, colour and size in walls in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the granite including cost, conveyance, loading, unloading and royalties of all materials, cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge. Ground Floor

461.19

-

1527.8

... More
Providing and painting two coats with synthetic enamel paint over a coat of zinc oxide primer of approved quality and approved shade confirmingto ISI on steel work to give an even shade in all floors at all height including sand papering and making the surface smooth with cost, coveyance, loading and unloadingof all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge.

49.47

-

151.5

... More
Paved road (Internal Driveway) Earth work in excavation of foundation treaches in all kinds of soil including moorum, stoney earth and earth mixed with boulders ( except sheet rocks and boulders requiring for blasting) including dressing and levelling the bed up to the required depth and depositing the excavated materials at places away from the work site with all leads and 1ifts, T&P shoring and shuttering and dewatering if required etc. comp. as directed by EIC.

662.45

-

217.6

... More
Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.

220.82

-

145.07

... More
Filling foundation and plinth with river sand, well watered, rammed including cost, conveyance, royalties of materials, cost of all labour and T&P required for the work etc. complete as per direction of EIC.

437.22

-

583.8

... More
C.C of prop. (1:4:8) in foundation using 40mm. Size broken hard granite metal of approved quality from approved quarry including lowering,laying concrete to required levels laid in layers not exceeding 150mm thick including cost,conveyance,royalities of all materials,cost of all labour,T & P required for the work etc.required to complete as per direction of EIC.

331.22

-

4510.6

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

22.57

-

6918.74

... More
Providing and laying 80mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

2174.6

-

789

... More
Painting two coat with approved brand of synthetic enamel paint of approved shade and quality over old/new wood and iron works including cost of paint, putty, scaffolding, T&P, cost, conveyance, cost of all materials and cost of all labour required for the work etc. complete as per the direction of EIC. (Paints of Berger/Nerolac/J&N /Asian/ ICI Brand is to be used.).

296.41

-

92.5

... More
INTERNAL P.H. & SANITARY WORK.

-

-

-

... More
WATER SUPPLY. Supplying, installing, fixing, jointing, testing and commissioning of approved make. Chlorinated Polyvinyl Chloride pipes (CPVC) SDR.11 pipes confirming to ASTM standards with necessary fittings for inetrnal toilet water supply upto 50 dia , and above 50mm dia pipe schedule 40 with fitting shall be schedule 80 ASTM IPS. The fittings and specials such as tees, elbows,couplers, bends, enlargers etc.,m with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50mm dia primer P-70, and solvent confirming to ASTM F-4931 / 724 All exposed pipe shall be painted with latex paint. (for shafts, basement ceiling ringmain Terrace & PRM).The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/ASTRAL/Oriplast/Hariplast or equivalent.

-

-

-

... More
20 mm dia C-PVC pipe SDR.11 GROUND FLOOR

13.3

-

235.3

... More
25 mm dia C-PVC pipe SDR.11 GROUND FLOOR

8

-

302

... More
32 mm dia C-PVC pipe SDR.11 ) GROUND FLOOR

3

-

429.7

... More
40 mm dia C-PVC pipe SDR.11 GROUND FLOOR

2

-

579.2

... More
20 mm dia C-PVC pipe SDR.11 FIRST FLOOR

17.6

-

244.5

... More
25 mm dia C-PVC pipe SDR.11 FIRST FLOOR

12.9

-

311.1

... More
32 mm dia C-PVC pipe SDR.11 FIRST FLOOR

5

-

440.2

... More
40 mm dia C-PVC pipe SDR.11 FIRST FLOOR

2

-

592.6

... More
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall

-

-

-

... More
GROUND FLOOR

12

-

56.4

... More
FIRST FLOOR

13

-

56.4

... More
Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer-in-charge.

-

-

-

... More
FIRST FLOOR

25

-

166.3

... More
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C.

-

-

-

... More
GROUND FLOOR

25.5

-

401.8

... More
FIRST FLOOR

36.8

-

401.8

... More
Supplying all materials, labour, T&P and fixing the following vitreous china Wall Hung Water Closet (European type W.C. pan) with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer-In-Charge.(MAKE-Jaquar Florentine & above/ Kohler/ Grohe or equivalent)

14

-

8391.4

... More
Supplying all materials, labour, T&P and fixing Metropole Flush Valve Regular 32mm Size (Concealed Body) with Exposed Shut Off Provision & 100mm Square Plate complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equvalent )

14

-

3646.8

... More
Supplying all materials, labour, T&P and fixing Health Faucet 15MM dia cp Health faucet 1.2mtr long,8mm Dia complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of the Engineer-In-Charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

15

-

1541.3

... More
Supplying all materials, labour, T&P and fixing standard sized Two way Bib cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

14

-

1654.4

... More
Supplying all materials, labour, T&P and fixing standard sized Robe Hook complete with all as per specification and direction of the Engineer in charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent)

15

-

642.2

... More
Supplying all materials, labour T&P and fixing of Under Counter wash basins with waste couple of approved make in all floor of approved quality including cutting the walls & floor and making good the damags with cement concrete e.t.c including all tsxes,duties,transportation e.t.c. All complete as per specification and direction of the Engineer-In-Charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

15

-

4558.9

... More
Supplying all materials, labour, T&P and fixing standard sized pillar cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

17

-

1974.1

... More
Supplying all materials, labour, T&P and fixing rectangular mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge.(Make AKP-35795 swivel mirrior 630x445 mm Rectangular shape or equivalent)

15

-

3872.4

... More
Supplying, installing, testing and commissioning of approved make White Viterous urinals 3.8 LPM supported by CI/MS bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flusing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains etc, complete. Including necessary wall cutting/chasing and making good, as required. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

11

-

10047.8

... More
Supplying all materials, labour, T&P and fixing standard sized Chromium Plated urinal sensor complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent)

11

-

7964.1

... More
Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap case complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent)

13

-

802

... More
Supplying all materials, labour, T&P and fixing standard sized Chromium Plated soap dispenser complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

11

-

3119.5

... More
Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel ring complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent)

6

-

1117.71

... More
Supplying all materials, labour, T&P and fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

8

-

1291.41

... More
Supplying all materials, labour, T&P and fixing standard sized 15mm dia angular Stop cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP angle stop cock with wall flange . (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

17

-

775.4

... More
Supplying all materials, labour, T&P and fixing standard sized SINK cock of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.(Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

2

-

1614.6

... More
Supplying all materials, labour, T&P and fixing standard sized of stainless steel KITCHEN SINK of Hindware/Jindal/Nirali of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge .(Nirali Olympia Anti -Scratch size- 950mmx510mm or equivalent

2

-

16835.1

... More
Supplying all materials, labour, T&P and fixing standard sized Chromium Plated Paper Holder complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws as per specification and direction of the Engineer in charge. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

15

-

1349.7

... More
Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard) pure Chill 80 SS RO + UV of size 640x450x1350 mm height with water storage capacity 80 liters along with 7 nos of filtration stages material SS 304 etc. all complete as per approved drawing, specification and direction of the EIC. (Make- Eureka Forbes)

2

-

77557.75

... More
Supplying all materials, labour, T&P and fixing standard sized Hand Dryer of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

4

-

31417.2

... More
Fixing of 25mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 25mm dia brass or gun metal full way valve.(Make- zoloto/Shakti or equivalent.)

2

-

912.5

... More
Fixing of 32mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto/Shakti or equivalent.)

4

-

1503.8

... More
Fixing of 40mm dia Brass/GM Fulway Valve confirming to IS : 781-1995 of approved make as per specification complete as per direction of Er-in-charge. 40mm dia brass or gun metal full way valve.(Make- zoloto/Shakti or equivalent.)

2

-

2155.8

... More
Supplying, installing, testing and commissioning butterfly valves with standard lever confirming to IS 13039 with necessary connecting fittings like flanges ,nuts and bolts etc., complete. 50mm dia. (Make- Zoloto/shakti or equivalent.)

1

-

3063.1

... More
Matrix Set-1 (WB 65X35 with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rail 60cm) E.W.C,(Size- 390 x 365 x 540, S TRAP) cm , & Cistern complete with fittings & seat cover,Wash Basin : 46 x 36 cm, one no. hinged rail 76 cm & 4 nos. of grab rails 60 cm. (Make: Jaquar Florentine & above/ Kohler/ Grohe or equivalent )

1

-

46658.6

... More
Supplying, fixing and testing PVC soil, waste, Rain and vent pipes (SWR) supreme confirming to IS13592 : 2013, type B with rubber ring/Solvent (confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Hariplast/Oriplast/Supreme

-

-

-

... More
40 mm dia

8

-

172.1

... More
50 mm dia .

3.7

-

200.2

... More
75 mm dia

20

-

255.8

... More
110 mm dia

22.14

-

360.9

... More
Supplying, fixing and testing PVC muilty floor trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete.Make:- (Supreme/Ashirbad/Astral).

14

-

169.9

... More
Supplying, fixing and testing PVC nanhani trap with SS frame and cover 75mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete.Make:- (Supreme/Ashirbad/Astral)

13

-

133.5

... More
Providing ,fixing , testing and commissioning of clean outs fabricated from heavy duty PVC pipe for waste and soil lines inside toilets for effective maintenance, laid true to finished floor level with brass chromium plated frame and screw type of cover and key for opening etc., complete. (Supreme/Ashirbad/Astral/Hariplast/Oriplast/Supreme)

-

-

-

... More
75 mm dia

4

-

125.4

... More
110 mm dia

6

-

217

... More
Providing ,fixing , testing and commissioning of approved make PVC vent cowl with necessary accessories etc., complete. (Supreme/Ashirbad/Astral)

-

-

-

... More
75 mm dia

5

-

83.5

... More
110 mm dia

6

-

123.4

... More
Internal Electrification, Fire Protection Works, HVAC System & Toilet Exhaut System

-

-

-

... More
Internal Electrification Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Length-5 Mtr.)

218

-

1051

... More
Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge.(Average Length of Looping : 3 Mtr)

272

-

514

... More
Supply & Recessed wiring for 6 Amp modular socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on same switch board as per direction of Engineer in Charge.

35

-

483.88

... More
Supply & Recessed wiring to 2 nos 6 Amp modular socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 1.6 mm thick 20 mm dia non-metalic PVC conduit with modular type 2 nos switch and 2 Nos. of modular socket ,6 module 18SWG modular GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required. including all accessories and connection as per direction of EIC. (Length of Point-3 Mtr.)

108

-

837

... More
Supply and fixing of 4module GI box with cover on surface or in recess including providing and fixing 5 pin 16 amps modular socket outlet and 16 amps modular type switch, connection, painting etc as required including all accessories and connection as per direction of EIC.

19

-

619

... More
Supply and Recessed wiring for projector/AC socket outlet with 16Amps modular socket with 16Amps modular control switch at nearest separate location connection, painting etc as required including all accessories and connection as per direction of EIC.

59

-

701

... More
Recessed sub main wiring with 2 Nos. Single Core 1.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor in 1.6 mm thick 20 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-Charge.

1275

-

130

... More
Recessed sub main wiring with 2 Nos. Single Core 2.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor 1.6 mm thick 20 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-charge.

1260

-

144

... More
Recessed sub main wiring with 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor 1.6 mm thick 20 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-charge.

1600

-

168

... More
Recessed sub main wiring with 2 Nos. Single Core 6.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 6 mm2 FRLS Copper Wire for Earth Continuity Conductor a1.6 mm thick 20 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-charge.

120

-

198

... More
Recessed sub main wiring with 4 Nos. Single Core 6.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 No. Single Core 4 mm2 FRLS Copper Wire for Earth Continuity Conductor in 1.6 mm thick 32 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-charge.

60

-

306

... More
Recessed sub main wiring with 4 Nos. Single Core 10.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 No. Single Core 6 mm2 FRLS Copper Wire for Earth Continuity Conductor in 1.6 mm thick 40 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-charge.

60

-

436

... More
Recessed sub main wiring with 4 Nos. Single Core 16.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 No. Single Core 10 mm2 FRLS Copper Wire for Earth Continuity Conductor in 1.6 mm thick 50 mm dia PVC conduit pipe as per SLD complete with making good the damages caused as required and including all accessories and connection as per Direction of Engineer-In-charge.

60

-

621

... More
Supply, delivery, installation and testing of 4+12 way TPN MCB DB with glazed door (IP-43) complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required and as per Direction of Engineer-In-Charge. ( But with out MCB/ RCCB/ Isolator)

4

-

2166

... More
Supply, delivery, installation and testing of 4+18 way TPN MCB DB with glazed door (IP-43) complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required and as per Direction of Engineer-In-Charge. ( But with out MCB/ RCCB/ Isolator)

8

-

2533

... More
Supply, delivery, installation and testing of 16 way SPN DB with glazed door (IP-43) complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required and as per Direction of Engineer-In-Charge. ( But with out MCB/ RCCB/ Isolator)

8

-

2122

... More
Supply and fixing of 6-32Amp rating 240 V C-Series Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as per Direction of Engineer-In-Charge.

288

-

132

... More
Supply and fixing of 25-40Amp rating 240 V DP Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 30mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as per Direction of Engineer-In-Charge.

8

-

2719

... More
Supply and fixing of 40Amp rating 415 V 4P Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as per Direction of Engineer-In-Charge.

8

-

4305

... More
Supply and fixing of 63Amp rating 415 V 4P Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required and as per Direction of Engineer-In-Charge.

4

-

4862

... More
Supply of 3.5C, 300Sq mm PVC insulated and PVC seathed XLPE Aluminum cable of 1.1 KV grade as required and as per Direction of Engineer-In-Charge.

55

-

1612

... More
Supply of 3.5C, 150Sq mm PVC insulated and PVC seathed XLPE Aluminum cable of 1.1 KV grade as required and as per Direction of Engineer-In-Charge.

25

-

841

... More
Supply of 3.5C, 50Sq mm PVC insulated and PVC seathed XLPE Aluminum cable of 1.1 KV grade as required and as per Direction of Engineer-In-Charge.

25

-

337

... More
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required and as per Direction of Engineer-In-Charge.

40

-

161

... More
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE/METAL pipe as required and as per Direction of Engineer-In-Charge.

10

-

58

... More
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required and as per Direction of Engineer-In-Charge.

25

-

123

... More
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required and as per Direction of Engineer-In-Charge.

30

-

126

... More
Supplying and making end termination with brass compression gland and aluminum lugs for 3.5C, 300Sq mm size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required and as per Direction of Engineer-In-Charge.

2

-

657

... More
Supplying and making end termination with brass compression gland and aluminum lugs for 3.5C, 150Sq mm size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required and as per Direction of Engineer-In-Charge.

2

-

468

... More
Supplying and making end termination with brass compression gland and aluminum lugs for 3.5C, 50Sq mm size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required and as per Direction of Engineer-In-Charge.

2

-

326

... More
Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG) including Busbars, interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: MAIN PANEL with 400A 4P MCCB (36kA) - 1 No, 400Amp, 4P Changeover-1 No., 50kA 4 Module Type-I+II SPD- 1 No., 63Amp 4P SFU set with fuses-1 Set as incoming, 250A 4P MCCB (36kA) - 2 Nos, 100A 4P MCCB (36kA) - 2 Nos, 63A 4P MCB (C-Curve) - 5 Nos, 40A 4P MCB (C-Curve) - 5 Nos, 32A 2P MCB (C-Curve) - 3 Nos as Outgoing and 3 Nos 500/5A CT, Multifunction Meter and 500A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used.

1

-

228170

... More
Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG) including Busbars, interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: HVAC PANEL with 250A 4P MCCB (36kA) - 1 No as incoming 100A 4P MCCB (36kA) - 6 Nos, 63A 4P MCB (C-Curve) - 6 Nos, 32A 2P MCB (C-Curve) - 6 Nos as Outgoing and 3 Nos 250/5A CT, Multifunction Meter and 250A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used.

1

-

112336

... More
Supply, installation, testing & commissioning of floor mounting front operated front access extensible type cubicle Indoor panel totally enclosed, dust and vermin proof with IP-42/55 protection with hinged and lockable doors. CRCA sheets (16 SWG) including Busbars, interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35 kAmp symmetrical for 1 sec at 415 V complete as per below specifications, as required as per direction of Engineer in Charge.: UPS PANEL with 100A 4P MCCB (36kA) - 1 No as incoming 100A 4P MCCB (36kA) - 6 Nos, 40A 4P MCB (C-Curve) - 6 Nos, 32A 2P MCB (C-Curve) - 6 Nos as Outgoing and 3 Nos 100/5A CT, Multifunction Meter and 100A Aluminum Bus Bars. All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used.

1

-

85144

... More
Supply delivery, installation, testing & commissioning of recessed mounted indoor type 36 watt 2 ' x 2' Square LED Luminaire fittings including all accessories, labour cost, T&P etc complete work as per Direction of EIC.

87

-

5133

... More
Supply delivery, installation, testing & commissioning of recessed mounted indoor type 15 watt Round LED Luminaire fittings including all accessories, labour cost, T&P etc complete work as per Direction of EIC.

300

-

1470

... More
Supplying, installation, testing and commissioning of 20 watt 240 VOLT batten type LED tube light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC.

4

-

455

... More
Supplying, installation, testing and commissioning of 5 watt 240 VOLT Mirror LED light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC.

10

-

340

... More
Supply, installation & testing of 300 MM Sweep HEAVY DUTY Exhaust Fan on Existing opening including loop connections and making good the damages caused complete as required and as per direction of Engineer-in-charge.

12

-

2882

... More
Supply & Fixing of Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. including all accessories, labour cost, T&P etc complete work as per Direction of EIC.

8

-

3356

... More
Supply & Laying of 25 mm X 6 mm GI earth strip at 0.5Mtr below ground level as strip earth electrode including soldering etc. as required and as per Direction of EIC.

80

-

129

... More
Supply & Laying of 25 mm X 6 mm GI earth strip on surface as strip earth electrode including soldering etc. as required and as per Direction of EIC.

60

-

77

... More
Supply & Laying of 6 SWG GI earth wire in recess for loop earthing etc. as required and as per Direction of EIC.

80

-

20

... More
Supply and fixing of lightning conductor finial made of 25mm dia 300 mm long, copper tube,having single prong at top,with 85mm dia 3 mm thick copper base plate including holes etc. complete as required and as per Direction of EIC.

12

-

619

... More
Supply and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required and as per Direction of EIC. (For horizontal run)

170

-

59

... More
Supply and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required and as per Direction of EIC. (For vertical run)

70

-

97

... More
Supply and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required and as per Direction of EIC.

10

-

63

... More
Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required and as per Direction of EIC.

40

-

151

... More
Supply and fixing of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required and as per Direction of EIC.

170

-

91

... More
Earthing with GI earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required and as per Direction of EIC.

12

-

3356

... More
Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.

101

-

405

... More
Recessed wiring to television point with clip in type modular television socket ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.

1

-

377

... More
Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.

104

-

554

... More
Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deep on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required as per the direction of Engineer in Charge.

8

-

183

... More
Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required as per the direction of Engineer in Charge.

2200

-

108

... More
Supplying and drawing one pair, 0.5 sq.mm FRLSH PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required as per the direction of Engineer in Charge.

1450

-

43

... More
Supply and drawing of TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid & protected with FRLSH PVC sheath in existing surface / recessed STEEL / PVC conduit as required as per the direction of Engineer in Charge.

20

-

46

... More
Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required as per the direction of Engineer in Charge.

1500

-

67

... More
FADS System Supply, installation, testing & commissioning of Microprossor based Intelligent Addrressable Main Fire Alarm Panel, Central Processing Unit with 2 loop module and each loop capacity of 120 Detectors per loop with total of 240 detectors and devices with loop length upto 2Km, Network Communication Card, Minimum 320 character graphics, LCD Display with touch screen or other keyboard and 65000 event history logs in the non volatile memory (EEPROM) power supply unit at 230+/-5%V, 72 Hrs back-up with 24V sealed maintenance free batteries with automatic charger.The panel shall have facility to connect printer to print out logs and facility to have integration with analog voice evacuation system and shall be complete with all accessories.

1

-

325000

... More
Supply, installation, testing & commissioning of 8 bit Microprocessor based addressable Multi Sensor Detector. The detector shall have group decision technology for faster response & avoid false alarms. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary switches. operating temparature 0-50 deg C.

88

-

3150

... More
Supply, installation, testing & commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.

6

-

3064

... More
Supply, installation, testing & commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.

6

-

3384

... More
Supply, installation, testing & commissioning of Response Indicator etc. complete as required and as per Direction of EIC.

20

-

150

... More
Supply & laying of FRLS copper cable of 2Cx1.5 Sq mm in suitable size PVC conduits for machines etc. complete as required and as per Direction of EIC.

400

-

95

... More
Supply & fixing of 1.6mm thick 25mm dia PVC conduit in recessed with 18SWG GI wire etc. complete as required and as per Direction of EIC.

250

-

48

... More
Supply, installation, testing & commissioning of 20x40 mm size auto glow Flom Board of 2.5mm thickness etc. complete as required and as per Direction of EIC.

10

-

1750

... More
HVAC & TOILET EXHAUST SYSTEM Supply instalation testing commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), with motor having 6 pole, minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. with refrigerant-cooled PCB for better performance complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 415V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. The compressor motor pole should be more than 4 for enhanced energy savings. COP of refrigerant circuit system for all systems shall be 6.83 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency.The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. Outdoor Unit complete with scroll compressor, condenser & its controller of Nominal Capacity-34 (18+16) HP

1

-

673219

... More
Supply instalation testing commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), with motor having 6 pole, minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. with refrigerant-cooled PCB for better performance complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 415V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. The compressor motor pole should be more than 4 for enhanced energy savings. COP of refrigerant circuit system for all systems shall be 6.83 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency.The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. Outdoor Unit complete with scroll compressor, condenser & its controller of Nominal Capacity-46 (14+14+18) HP

1

-

920589

... More
Supply instalation testing commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), with motor having 6 pole, minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. with refrigerant-cooled PCB for better performance complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 415V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. The compressor motor pole should be more than 4 for enhanced energy savings. COP of refrigerant circuit system for all systems shall be 6.83 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency.The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. Outdoor Unit complete with scroll compressor, condenser & its controller of Nominal Capacity-28 (12+16) HP

1

-

570253

... More
Supply instalation testing commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), with motor having 6 pole, minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. with refrigerant-cooled PCB for better performance complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 415V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. The compressor and VRV/VRF Outdoor make should be same. The compressor motor pole should be more than 4 for enhanced energy savings. COP of refrigerant circuit system for all systems shall be 6.83 minimum at 50% load, at AHRI Condition in cooling mode. The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respect to load for better comfort and energy efficiency.The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. Outdoor Unit complete with scroll compressor, condenser & its controller of Nominal Capacity-36 (18+18) HP

1

-

704426

... More
Supply instalation testing commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall have dual sensor which detect the presence of people and floor temperature to provide comfortable air-conditioning and energy saving. The sensor should detects human presence and adjust the airflow direction automatically to prevent drafts. Room temperature should increase upto 4 deg C or the indoor to be switched off when no people are detected or as per user preference. The sensor should detects the floor temperature and automatically adjusts the operation of the indoor unit to reduce the temperature difference between the ceiling and the floor. The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality. Round Flow Cassette AC with cordless Remote, Nominal Capacity-3.3 Tr

16

-

60455

... More
Supply instalation testing commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall have dual sensor which detect the presence of people and floor temperature to provide comfortable air-conditioning and energy saving. The sensor should detects human presence and adjust the airflow direction automatically to prevent drafts. Room temperature should increase upto 4 deg C or the indoor to be switched off when no people are detected or as per user preference. The sensor should detects the floor temperature and automatically adjusts the operation of the indoor unit to reduce the temperature difference between the ceiling and the floor. The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality. Round Flow Cassette AC with cordless Remote, Nominal Capacity-2.65 Tr

9

-

58994

... More
Supply instalation testing commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall have dual sensor which detect the presence of people and floor temperature to provide comfortable air-conditioning and energy saving. The sensor should detects human presence and adjust the airflow direction automatically to prevent drafts. Room temperature should increase upto 4 deg C or the indoor to be switched off when no people are detected or as per user preference. The sensor should detects the floor temperature and automatically adjusts the operation of the indoor unit to reduce the temperature difference between the ceiling and the floor. The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality. Round Flow Cassette AC with cordless Remote, Nominal Capacity-2.08 Tr

4

-

53599

... More
Supply instalation testing commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall have dual sensor which detect the presence of people and floor temperature to provide comfortable air-conditioning and energy saving. The sensor should detects human presence and adjust the airflow direction automatically to prevent drafts. Room temperature should increase upto 4 deg C or the indoor to be switched off when no people are detected or as per user preference. The sensor should detects the floor temperature and automatically adjusts the operation of the indoor unit to reduce the temperature difference between the ceiling and the floor. The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality. Round Flow Cassette AC with cordless Remote, Nominal Capacity-1.65 Tr

4

-

51940

... More
Supply instalation testing commissioning of following minimum capacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. The cassettes units shall have dual sensor which detect the presence of people and floor temperature to provide comfortable air-conditioning and energy saving. The sensor should detects human presence and adjust the airflow direction automatically to prevent drafts. Room temperature should increase upto 4 deg C or the indoor to be switched off when no people are detected or as per user preference. The sensor should detects the floor temperature and automatically adjusts the operation of the indoor unit to reduce the temperature difference between the ceiling and the floor. The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality. Round Flow Cassette AC with cordless Remote, Nominal Capacity-1.05 Tr

1

-

48470

... More
Supply, installation, testing & commissioning of 2.08 Tr capacity of Wall mounted type indoor,capable of varying the air volume(VAV) as per requirement of the airconditioned space with cordless remote.

2

-

31648

... More
Supply, installation, testing & commissioning of 1.65 Tr capacity of Wall mounted type indoor,capable of varying the air volume(VAV) as per requirement of the airconditioned space with cordless remote.

5

-

30618

... More
Supply, installation, testing & commissioning of 1.05 Tr capacity of Wall mounted type indoor,capable of varying the air volume(VAV) as per requirement of the airconditioned space with cordless remote.

10

-

28042

... More
Supply, installation, testing & commissioning of 0.8 Tr capacity of Wall mounted type indoor,capable of varying the air volume(VAV) as per requirement of the airconditioned space with cordless remote.

4

-

27600

... More
Supply instalation testing commissioning of Non VRV Hi-wall type Split UNIT of 1.05 Tr with OEM manufactured rotary compressor, three Star rated non inverter type with stablizer (R410A/R32- refrigerant) suitable for 230V, 50 Hz, single phase AC. & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required with Refrigerant Copper Piping, PVC drain piping including insulation Kinni foam connections with units with U-trap, nipple clamps etc.

1

-

27500

... More
Supply & fixing of Copper Refnet/Y-Connector of different sizes etc. complete as required and as per Direction of EIC.

52

-

3500

... More
Supply & fixing of Wireless Remote controller with batteries for different capacities of Indoor AC units. etc. complete as required and as per Direction of EIC.

55

-

1380

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 41.3mm dia Suction Line with 19mm thick insulation.

14

-

1980

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 34.9mm dia Suction Line with 19mm thick insulation.

25

-

1690

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 28.6mm dia Suction Line with 19mm thick insulation.

43

-

1375

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 22.2mm dia Suction Line with 19mm thick insulation.

26

-

1050

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 19.1mm dia Suction Line with 19mm thick insulation.

33

-

900

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 15.9mm dia Suction Line with 19mm thick insulation.

115

-

725

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 12.7mm dia Suction Line with 19mm thick insulation.

164

-

650

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 19.1mm dia Liquid Line with 13mm thick insulation.

14

-

900

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 15.9mm dia Liquid Line with 13mm thick insulation.

20

-

725

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 12.7mm dia Liquid Line with 13mm thick insulation.

36

-

575

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 9.5mm dia Liquid Line with 13mm thick insulation.

197

-

500

... More
Supply,installation, testing and commissioning of Interconnecting refrigerant Copper pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units etc. complete as required and as per Direction of EIC. 6.4mm dia Liquid Line with 13mm thick insulation.

170

-

450

... More
Supply,installation, testing and commissioning of 25mm dia PVC pipe along with accessories insulated with 6 mm thick closed cell elastomeric nitrile rubber etc. complete as required and as per Direction of EIC.

58

-

170

... More
Supply,installation, testing and commissioning of 32mm dia PVC pipe along with accessories insulated with 6 mm thick closed cell elastomeric nitrile rubber etc. complete as required and as per Direction of EIC.

65

-

207

... More
Supply,installation, testing and commissioning of 40mm dia PVC pipe along with accessories insulated with 6 mm thick closed cell elastomeric nitrile rubber etc. complete as required and as per Direction of EIC.

100

-

224

... More
Supply & Refrigerant Gas (R410A/R32) charging for the entire circuit etc. complete as required and as per Direction of EIC.

360

-

1322

... More
Supply & laying of control cum transmission wiring of 2Cx1.0Sq mm shielded copper cable in suitable size PVC conduits between Indoor & Outdoor units etc. complete as required and as per Direction of EIC.

716

-

75

... More
Supply & laying of control/communication cable of 4Cx2.5 Sq mm copper cable in suitable size PVC conduits between Indoor & Outdoor units etc. complete as required and as per Direction of EIC.

50

-

165

... More
Supply & laying of power cable of 4Cx10.0 Sq mm copper cable of 1.1kV grade in suitable size PVC conduits between Indoor & Outdoor units etc. complete as required and as per Direction of EIC.

30

-

475

... More
Supply & laying of power cable of 4Cx25.0 Sq mm copper cable of 1.1kV grade in suitable size PVC conduits between Indoor & Outdoor units etc. complete as required and as per Direction of EIC.

10

-

1065

... More
Supply, installation, testing & commissioning of 680CHM Circular Duct fan suitable for 200V, 50 Hz, single phase supply etc. complete as required and as per Direction of EIC.

3

-

6610

... More
Supply, installation, testing & commissioning of 420CHM Circular Duct fan suitable for 200V, 50 Hz, single phase supply etc. complete as required and as per Direction of EIC.

4

-

5280

... More
Supply, installation, testing & commissioning of 262CHM Circular Duct fan suitable for 200V, 50 Hz, single phase supply etc. complete as required and as per Direction of EIC.

1

-

4950

... More
Supply, installation, testing & commissioning of 150mm (Type-B) dia PVC pipe with fittings like Tee, Elbow, Reducer with solvent, supporting materials, nut, washer etc. complete as required and as per Direction of EIC.

100

-

579

... More
Supply, installation, testing & commissioning of 100mm (Type-B) dia PVC pipe with fittings like Tee, Elbow, Reducer with solvent, supporting materials, nut, washer etc. complete as required and as per Direction of EIC.

100

-

313

... More
Supply, installation, testing & commissioning of 100mm dia PVC flexible pipe with fittings like Tee, Elbow, Reducer with solvent, supporting materials, nut, washer etc. complete as required and as per Direction of EIC.

50

-

313

... More
Supply, installation, testing & commissioning of 100mm dia Disc Diffuser etc. complete as required and as per Direction of EIC.

60

-

422

... More
Supply, installation, testing & commissioning of suitable size Outer Steel cowl for exhaust system etc. complete as required and as per Direction of EIC.

8

-

877

... More
Supply & laying of FRLS copper cable of 2Cx2.5 Sq mm in suitable size PVC conduits for machines etc. complete as required and as per Direction of EIC.

10

-

50

... More
CCTV, NETWORKING & EPBAX SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of 24 10/100/1000 PORTS + 4 SFP+ L3 switch as per technical specification and as per direction of EIC.

1

-

120000

... More
Supply, installation, testing and commissioning of 24 POE+ 10/100/1000 PORTS + 4 SFP+ L2 switch as per technical specification and as per direction of EIC.

6

-

70000

... More
1000BASE-LX Single-mode SFP Module, 10 km as per technical specification and as per direction of EIC.

12

-

10000

... More
Supply, installation, testing and commissioning of CAT6 UTP cable as per technical specification and as per direction of EIC.

5940

-

18

... More
Supply, installation, testing and commissioning of dual face plate information outlet with surface mount box as per technical specification and as per direction of EIC.

132

-

85

... More
Supply, installation, testing and commissioning of 24 port unloaded patch panel as per technical specification and as per direction of EIC.

5

-

3750

... More
Supply, installation, testing and commissioning of CAT6 information outlet and as per direction of EIC.

264

-

250

... More
Supply, installation, testing and commissioning of 1 meter CAT6 patch cord as per technical specification and as per direction of EIC.

132

-

140

... More
Supply, installation, testing and commissioning of 3 meter CAT6 patch cord as per technical specification and as per direction of EIC.

132

-

160

... More
Supply, installation, testing and commissioning of 15U wall mount network rack with FAN, PDU and cable manager as per technical specification and as per direction of EIC.

4

-

5500

... More
Supply, installation, testing and commissioning of 42U floor mount server rack with necessary accessories as per technical specification and as per direction of EIC.

1

-

56000

... More
Supply, installation, testing and commissioning of 6 Core single mode fibre cable outdoor and as per direction of EIC.

600

-

47

... More
Supply, installation, testing and commissioning of 12 port LIU includes pigtail and cupler with accessories as per technical specification and as per direction of EIC.

5

-

13000

... More
Supply, installation, testing and commissioning of Single mode fibre patch cord 1 meter as per technical specificationand as per direction of EIC.

12

-

1350

... More
Supply, installation, testing and commissioning of 25'' medium duty PVC cashing capping as per technical specification and as per direction of EIC.

2079

-

39

... More
Supply, installation, testing and commissioning of 32'' PVC cashing capping as per technical specification.

2673

-

47

... More
Supply, installation, testing and commissioning of 40 mm HDPE Pipe for OFC Cable and as per direction of EIC.

200

-

59

... More
Supply, installation, testing and commissioning of 1 KVA UPS and as per direction of EIC.

6

-

4100



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.