Odisha Lift Irrigation Corporation Limited Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Lift Irrigation Corporation Limited - OLICL Tender

Works
Civil And Construction
Electrical Goods and Equipments
Excavation
Electrical and Electronics
Water Storage And Supply
Eprocure
Opening Date19 Feb 2025
Closing Date17 Mar 2025
Tender Amount₹ 15,66,51,000 
Notes
Download

AI Insights

Bid Capacity
... View More
The bid capacity required in the given tender can be calculated using the formula: Assessed bid capacity = (2x A x N - B) Where: A = maximum value of work executed in any one financial year during last five years (updated to the current price level) B = value at current price level of the existing commitments and ongoing works to be completed during the period of completion of works for which bids are invited N = No. of years prescribed for completion of the work for which the bids are invited. Additionally, the Qualifying quantity can be calculated as: Qualifying quantity = 0.4 x (estimated quantity of work) x 12 month/ period of completion Example (minimum quantity required): 0.4 x 500 nos bore well x 12 / 6 = 400 Nos BW to qualify The bidder should also have a minimum working capital requirement (credit facility) of 20% of the amount put to tender, which is Rs. 313.00 Lakhs.
Technical Capacity
... View More
The required prior work experience for the bidder includes satisfactorily completing similar work, which is a composite work of drilling, energisation, and commissioning. In the case of a single prime contractor, the bidder should have completed at least one similar work of value not less than Rs. 627.00 Lakhs, which is 40% of the proposed contract value. In the case of a joint venture, the bidder or their identified sub-contractor (JV partner) should have satisfactorily completed similar work of value not less than Rs. 251.00 Lakhs for drilling work and Rs. 376.00 Lakhs for electrical work, which is 40% and 60% of the value mentioned for a single prime contractor, respectively. The bidder should have executed a minimum quantity of similar major items of work, which is 40% of the estimated annual quantity of execution. For example, if the estimated quantity of work is 500 nos bore well and the period of completion is 6 months, the qualifying quantity would be 0.4 x 500 x 12/6 = 400 nos bore well. A weightage of 10% per year shall be given on the cost of satisfactorily completed works of previous years to bring them to the current price level. The bidder should have experience and resources sufficient to meet the aggregate of the qualifying criteria for the individual packages, and their available bid capacity should be more than the total estimated cost put to tender. The bidder should submit proof of their work experience, including detailed correspondence address, fax number, and email of the authority issuing the certificate. The bidder should also submit annual I.T. Return of the last 5 years for assessment of financial soundness and furnish other documents. The bidder's work experience and financial soundness will be assessed based on the documents submitted. The bidder should have a satisfactory completion record and should not have any pending criminal cases against them. The bidder should submit a declaration that no near relatives are working in the cadre of a Junior Engineer and above in the organization. The bidder should not have any record of performance such as absconding from work, works not properly completed as per contract, inordinate delays in completion, financial failure. The bidder should not have produced any false/fake certificates in their tender. The bidder should not have any pending litigation against them for non-payment to agencies/laborers. The bidder should submit original certificates and other credentials furnished along with the tender as and when required to verify. Failure to produce original documents in time will lead to disqualification. The required prior work experience values and percentages of similar works completed are: - Rs. 627.00 Lakhs (40% of the proposed contract value) for a single prime contractor - Rs. 251.00 Lakhs (40% of the value mentioned for a single prime contractor) for drilling work in a joint venture - Rs. 376.00 Lakhs (60% of the value mentioned for a single prime contractor) for electrical work in a joint venture - 40% of the estimated annual quantity of execution for similar major items of work.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cost of 200mm dia PVC C.S. Casing Pipe of reputed make as per IS-12818/2010 specification. Manufacturer name should prominently be marked with CIPET test certification in the body of the pipe in indelible ink or stenciled to the satisfaction of Engineer-in-charge

6760

-

-

... More
Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the well including suppply and use of all necessary equipment and labour as per the direction of the Engineer-in-charge

500

-

-

... More
Conducting yield test through pumping for minimum 6-8 hours including supply of required pump set having 3.5 LPS discharge at 70 Mtr. head, 15KVA D.G. Set and a container of 200 ltrs. Capacity as required to suit the site condition as per the direction of the Engineer-in-charge including supply of tools plants labourers for lowering and lifting the pump set and measuring the yield of the bore well .

500

-

-

... More
XLPE insulated ( heavy duty ) armoured aluminium electric cable of size 3 core x 6 sqmm. with allumium conductor for use in 3 phase system in working voltage up to 1100 volt at 50 HZ confirming to IS 7098 part -I- 1988 & as per the particulars mentioned .

5000

-

-

... More
Cost of 63 mm. dia. HDPE 80 (PN 10) delivery pipe as per IS-4984 / 2016.

16250

-

-

... More
Cost of 63 mm. dia. HDPE 80 (PN 6) delivery pipe as per IS-4984 / 2016.

11250

-

-

... More
8 mm Steel Wire Rope with PVC coated best quality suitable for borewell

55000

-

-

... More
3 core 2.5 sqmm submersible Flat Cable with bunched copper conductor insulated and sheathed with PVC for submersible pump motor with voltage up to 1100volt confirming to IS 694/1990

2500

-

-

... More
200mm dia Bore well cap (C.I.) best quality suitable for borewell

500

-

-

... More
63 mm dia G.I Bend with Socket confirming to lS No.1239 (Pt‐II/1992)

500

-

-

... More
63 mm dia Stainless Steel threaded nipple of 15 Cm long confirming to lS 1239 ‐ Pt‐II/1992

1000

-

-

... More
FTH SS Nut bolt as per IS specification suitable for fitting of stainless steel threaded nipple

2000

-

-

... More
63mm dia C.I. gate valve of ISI mark.

500

-

-

... More
Pannel Chamberwith FLYASH Brick massonary in CM(1:6) of size 1.2m x 1.2m x 2.1m including A.S, Flooring 2.5 cm depth in cm (1:2:4) sand filling, plastering in cm (1:6) curring etc in complete as per direction of Engineer-in-Charge

500

-

-

... More
Writing of required data and information on Pannel Chamber

115

-

-

... More
Cable clip of reputed brand

5000

-

-

... More
Installation of submersible pump inside the bore well fitting of HDPE pipe, tying the pump set with wire rope, connecting the supply line and submersible cable with starter, fixing the pannel board completing all the electrical installation, charging the project and making trial run etc. complete. as per the direction of the site engineer-in-charge ( Pump & starter will be supplied by the Department )

500

-

-

... More
LT panel box (fibre with water proofing provision) of size 30cmx25cmx15cm with kitkat fitted over bakalite board including pole clamp arrangement.

500

-

-

... More
32 Amp. Kitkat as per IS specification of reputed brand

1500

-

-

... More
Coil earthing with No.8 GI wire using required quantity of common salt, charcoal , GI nut bolt including digging the earth pit of size 1.2mtr. X 1.2mtr.x3mtr. And digging the wire trench and refilling after completion of earthing including supply of all materials trnsportation etc. complete as per the direction of the site engineer-in-charge

500

-

-

... More
Transpotation of required PVC C.S./A.S.T.M. Pipe for casing and delivery, S/S Pump set & control pannel with other petty materials etc. from store to work site.

500

-

-

... More
Construction & erection of 11/0.416 KV, 25 KVA (BIS level-II), Star rated (As per DISTCOM specification) D.P.sub-station confirming to RE Rules,1956 mounted on 2.8 Mtr. Long structure supported in 300 Kg. 9 Mtr. Long PSC pole, transformer mounting channel & top channel made 0f 2.8 Mtr. Long 100x50x6 mm M.S. channel, transformer belting on 2.8 Mtr. long 50 x 50 x 5 mm M.S. Angle(all REC.SPN. Std.F-3) with all accessories like 3 pole 11 KV HG Fuse (F-5) & A.B.Switches(F-9) both mounted on 2.8M long 75x40x6 mm M.S. Channel and supported by 1.0 mtr. long 50x50x5 mm M.S. Angle with 3 nos. 11 KV lightening Arrestors and Distribution box for 25 KVA S/S, 4 no. Pipe earthing(F-2), including cost of 50 sqmm 3.5 Core PVC cable carping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings i.e. FI Pipe Earthing 40 Dia Medium gauge 3 mtrs. Long, fixing of stay set with 0.5 Cum cement concret foundation 1:3:6 of required size , L.T.Distribution box including Kit Kat (100 AMP) fuse with MCCB (As per DISTCOM specification) 3 1/2 x 95 sqmm. PVC Cable , Barbed Fencing (size 15' x 10') with constn. of retaining wall, erection of RCC fencing post, Sand filling and metal spreading, Fixing of Iron gril gate etc. as per DISTCOM specification .Nuts & Bolts, Brackets, Cable sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing, inspection and commissioning including painting in Navy Blue colour band with inscription of OLIC in each Pole.

108

-

-

... More
Construction & erection of 11/0.416 KV, 63 KVA (BIS level-II) rated (As per DISTCOM specification) D.P.sub-station confirming to RE Rules,1956 mounted on 2.8 Mtr. Long structure, supported in 300 Kg. 9 Mtr. Long PSC pole,transformer mounting channel & top channel made 0f 2.8 Mtr. Long 100x50x6 mm M.S. channel, transformer belting on 2.8 Mtr. long 50 x 50 x 5 mm M.S. Angle(all REC.SPN. Std.F-3) with all accessories like 3 pole 11 KV HG Fuse (F-5) & A.B.Switches(F-9) both mounted on 2.8M long 75x40x6 mm M.S. Channel and supported by 1.0 mtr. long 50x50x5 mm M.S. Angle with 3 nos. 11 KV lightening Arrestors and Distribution box for 63 KVA S/S, Pipe earthing(F-2), including cost of 50 sqmm 3.5 Core PVC cable carping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings i.e. FI Pipe Earthing 40 Dia Medium gage 3 mtrs. Long,fixing of stay set with 0.5 Cum cement concret foundation 1:3:6 of required size , L.T.Distribution box including Kit Kat(200AMP) fuse with MCCB (As per DISTCOM specification) 3 1/2 x 35 sqmm. PVC Cable , Barbed Fencing (size 15' x 10') with constn. of retaining wall, erection of RCC fencing post, Sand filling and metal spreading, Fixing of Iron gril gate etc. as per DISTCOM specification .Nuts & Bolts, Brackets, Cable sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing, inspection and commissioning including painting in Navy Blue colour band with inscription of OLIC in each Pole.

5

-

-

... More
Construction & erection of 11/0.416 KV, 100 KVA (BIS level-II) star rated (As per DISTCOM specification) D.P.sub-station confirming to RE Rules,1956 mounted on 2.8 Mtr. Long structure, supported in 300 Kg. 9 Mtr. Long PSC pole,transformer mounting channel & top channel made 0f 2.8 Mtr. Long 100x50x6 mm M.S. channel, transformer belting on 2.8 Mtr. long 50 x 50 x 5 mm M.S. Angle(all REC.SPN. Std.F-3) with all accessories like 3 pole 11 KV HG Fuse (F-5) & A.B.Switches(F-9) both mounted on 2.8M long 75x40x6 mm M.S. Channel and supported by 1.0 mtr. long 50x50x5 mm M.S. Angle with 3 nos. 11 KV lightening Arrestors and Distribution box for 100 KVA S/S, Pipe earthing(F-2), including cost of 50 sqmm 3.5 Core PVC cable carping & padding of Poles, Danger board at each Pole, Anti Climbing Devices & all other necessary fittings i.e. FI Pipe Earthing 40 Dia Medium gage 3 mtrs. Long,fixing of stay set with 0.5 Cum cement concret foundation 1:3:6 of required size , L.T.Distribution box including Kit Kat (200 AMP) fuse with MCCB (As per DISTCOM specification) 3 1/2 x 35 sqmm. PVC Cable , Barbed Fencing (size 15' x 10') with constn. of retaining wall, erection of RCC fencing post, Sand filling and metal spreading, Fixing of Iron gril gate etc. as per DISTCOM specification .Nuts & Bolts, Brackets, Cable sockets etc. including cost of all materials, labour, transportation complete with liasioning for testing, inspection and commissioning including painting in Navy Blue colour band with inscription of OLIC in each Pole.

2

-

-

... More
Construction of 3 phase 11 KV line as per REC standard confirming to RE Rules 1956 with 300 Kg. 9 Mtr. Long PSC pole support in 50 Mtr. Span.55sqmm AAA Conductor with double disc arrangement,11KV "V" cross arm with required nos. of 11 KV B & S disc. Insulators and 11KV pin insulators, carping & paddig of poles,danger board at each pole, anticlimbing devices.Stay set at each bending point and double stay at end point with 18mm G.I. H.T. stay, concreting of stay with anchor plate etc. including cost of materials, labour, transportation, inspection & commissioning etc. (As per DISTCOM specification) complete including painting in Navy Blue colour band with inscription of OLIC in each Pole

34.5

-

-

... More
Construction of 3 phase L.T. Line with supports of 200 kg PSC pole of 8 mtrs. Long of span length of 30 mtr to 35 mtr. with 3x35+1x25 mm2 A.B. Cable with required materials, piercing connector, Pannel, etc. including cost of materials, labour, transportation etc. complete including painting in Navy Blue colour band with inscription of OLIC in each Pole.

77

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.