Odisha Lift Irrigation Corporation Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
Refer DocumentsDocument Cost
₹ 6,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_OLIC_84104_10Bid Award Id
ViewTender No
Bid Id No.14 /OLIC (CTC)Dt.07.12.22Tender Authority
Odisha Lift Irrigation Corporation Limited ViewPurchaser Address
-Website
http://http://www.odishalift.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Fly Ash Brick masonry 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
10.29
-
5135.03
Fly Ash Brick masonry 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
8.11
-
5168.36
Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge. (a) Plinth Band
4.2
-
133.32
Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge. (b) Roof Slab and Chhaja
16.73
-
439.45
Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge. ( c) Lintle
3.89
-
268.66
R.Cement Concrete (1:2:4) with 4cm size h.g.c.b. Chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. co
2.67
-
7909.85
M.S. reinforcement for R.C.C. work including supplying, cutting, bending, binding & tying the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500)
1.94
-
5752.96
12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
85.77
-
153.88
Dri Brick Khoa rammed to 4" size in flooring
7.56
-
328.72
2.5cm A.S Flooring in C.C (1:2:4) using 12mm size HBG Chips.
7.56
-
359.31
Supply & Fixing of M.S Door (2.0m x 1.0M size)
1
-
8000
White washing 3 coats with approved quality stone lime.
35.81
-
12.73
Colour washing 2coats with cement paint including cost of approved quality colour.
52.89
-
13.43
Filling the foundation and plinth with excavated material as directed by the Engineer-incharge.
92.31
-
108.55
Electrical wiring of Pump Chamber
1
-
3000
Cost for Laying & Fitting of M .S.Tee and ARV and Butter Fly Valve etc complete.
2
-
1000
Labour charges for writting of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
1
-
1000
Cost of 7.5HP Submersible pump set total head of 25 Mtrs capable to discharge 900 LPM with squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class "F" insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC Power Supply suction delivery= 100mmx100mm with BEE Star rated energy efficiency pump |& as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares.
1
-
39996
Cost of Automatic Star Delta Control panel upto 10HP pumpset
1
-
12080
Cost of 63 Amp. Main Switch Triple pole & natural of voltage range 440 volt of re-wirable fuse and shall confirming to IS-4064(PT-I& ) with ISI mark including all taxes etc.
1
-
2537
Cost of 4 KVAR Capacitor
1
-
1831
Cost of 3 Core x 10mm2 Tarpodar cable XLPE (Cross link polyethylin) confirming to IS-7098(part-II ) including laying below 0.9mtr of the ground and filling the excavated materials including watering and rammin including all taxed etc.
30
-
111
Cost of 2.5sqmm x 3core flat Cable
50
-
109
Labour charges for connection of main switch to starter and starter to motor with connection of other electrical fittings etc. complete as per direction of the Engineer-incharge.
1
-
2000
Cost of Tool Kit comprising of Tester, Screw driver, DE Spanner, Cutting Plier, Ring Spanner for suitable maintenance of LIP
1
-
2000
Cost of 100mm. dia nominal bore G.I.pipe having wall thickness 4.5mm.Elecrical resistance welded.Medium class confirming to IS 1239(Pt-1/2004) with socketed at one end the other end protected with plastic thread protector.The socket confirming to IS-1239 ( pt-I/1992) with latest amendmewnts in random length of 4 to7 mtrs. Each pipe should bear ISI Certfication & manufacturers name/Trade mark including all taxes etc. with guarantee.
27
-
884
Cost of 100mm dia G.I.Socket
5
-
159
Cost of 200x100mm dia M.S.TW Cap
1
-
347
Cost of M.S.Clamp
1
-
662
Cost of 12mm dia PVC Insulated Steel Wire rope
50
-
70
Cost of 100mm dia G.I. Bend confirming to IS-1239(Pt-II 1992) including all taxes etc.
3
-
853
Cost of 100mm dia G.I.Flange confirming to IS-6392/1971 including all taxes etc.
6
-
478
Cost of 100mm CI double flanged Non-Return Valve swing type PN-1.0 as per IS:5312 part-I with by pass arrangement.
1
-
5182
Cost of 160mm x100mm dia G.I.reducer
1
-
418
Supply of 160mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat President or Secretary.
102
-
348.19
Cost of 160 mm Ø PVC End Cap ( W.P. 10 Kgf/cm2 ) conforming to IS - 4995/ 1988 with latest ammendment.
5
-
159
Cost of 50mm dia Air release valve with saddle &Raiser pipe.The air release valve shall confirm to IS14845 with ISImark including all taxes &royality etc.
1
-
2405
Cost of 160mm x 160mmx110mm dia MS Tee with control arrangements.
1
-
4800
Fitting of un-plasticised 200mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
102
-
93.99
Labour charges for Installation and delivery fitting including fitting of Sluice Valve, NR Valve, Air Release Valve, PVC Tee and lowering of pump and transportation etc complete. & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding etc. complete as per the direction of the Engineer-incharge.
1
-
6000
Foundation Nut and Bolt, Rubber Insertion etc
1
-
1942.76
Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25 KVA S/S, G.I.pipe earthing with 25X5mm G.I.Flats including cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, FFly Ash Brick masonry boundary wall ( size (15'x10') with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.
1
-
340000
Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm Insulated Conductor , double disc and average span 50mtr with 1 Intermediate pole, 11 KV "V" Cross arm, with required No.of 11 KV T & C Disc. Insulators in tension point & 11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc. including cost of all materials, labour transportation,inspection & commissioning etc. complete.
0.5
-
822314
Evaluation Notes How It Works ?