Odisha Lift Irrigation Corporation Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Lift Irrigation Corporation Limited - OLICL Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date16 Aug 2024
Closing Date4 Sep 2024
Tender Amount₹ 22,48,064 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge.

2.83

18925

6687.33

... More
Brick work with Fly ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.

2.22

13162

5929.25

... More
Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in superstructure per cum etc. complete as per the Engineer-incharge.

7.45

44421

5962.58

... More
12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.

96.89

19367

199.89

... More
R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.

8.1

72950

9006.25

... More
2.5 cm A.S. Flooring with C.C. (1:2:4) using 12mm size black hard granite crusher broken chips of approve quality for approve quorry including water and curring with cost taxes royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.

7.5

3299

439.88

... More
Rigid smooths centering and shuttering for RCC works including false work and dismentgalling then after casting including cot os materials complete. (a) RCC walls and fins including attached pillasters

57.4

61087

1064.24

... More
b) Chajja/Roof slab

12.61

9596

761.04

... More
c) Lintel

1.27

729

574.79

... More
d) RCC Beams, culumns, grider & Bressers etc

3.96

4723

1192.71

... More
e) RCC foundation an footing beases of columns etc.

11.29

3607

319.56

... More
Dry brick rammed Khoa (10 cm) thick well watered and rammed inluding all cost as per specification in complete.

7.5

3047

406.38

... More
Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500)

4.52

38251

8462.81

... More
Filling the foundation and plinth with excavated material as directed by the Engineer-incharge.

17.33

2596

149.83

... More
Filling the foundation and plinth in trench of HDPE Pipe with the excavated material as directed by the Engineer-incharge. (Mechanical 60% & Manual 40%)

541.2

36985

68.34

... More
White washing 3 coat with approve good stone lime including cost conveyance charges of materials including supply of labour, gum, indigo etc. required for the work complete as directed by the Engineer-incharge.

35

611

17.47

... More
Finishing wall with water proofing cement paint of approved shade two coats to NEW work to give an even shade including cost of cement paints. etc. complete as per the direction of Engineer – in Charge.

57.95

2663

45.96

... More
Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.

1

1000

1000

... More
Labour for fitting and fixing for door and window etc. complete as per the direction of the Engineer-incharge.

2.75

220

80

... More
Cost of grill for window

0.25

1836

7345

... More
Cost of Iron shutter for door

0.65

4774

7345

... More
Priming 1 coat with any appproved Primer

5.5

403

73.33

... More
Painting two coats with approved paint on new work

5.5

998

181.46

... More
Cost, Supplying of ISI marked 160 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 for water supply as per IS 4984/2016 in the following Nominal diameter, Grades of materials, Pressure rating including the rates of ex-factory, transportation, pre & post inspection, Cess etc complete but excluding the cost of GST etc. complete as per the direction of the Engineer-incharge.

902

391855

434.43

... More
Fitting and Fixing 160 mm dia High Density Polythelene (HDPE) Pipes PE 80-PN 4 Pipe including jointing the pipe including fitting and fixing of required no. of Riser Tee for outlet and Shaddle and nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.

902

287232

318.44

... More
10 HP/7.5 KW Energy efficiency Submersible pumpset of total head 25 mtr having 1300 LPM discharge of reputed brand with BEE Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamp & 30 mtr of 4.00 sqmm flat cable and Impeller: Bronze grade LTB-2 of IS 318/1981 confirming to IS specification including all cost, conveyance, cess etc complete but excluding cost of GST etc. complete as per the direction of the Engineer-incharge.

1

39611

39611

... More
Labour charges for installation of 10HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge.

1

7662

7662

... More
100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark.

42

51934

1236.53

... More
100 mm dia G.I. bend IS No.1239(Part-II/1992)

3

2479

826.53

... More
100 mm dia G.I. flange IS No.6392 / 1971

6

2618

436.41

... More
100mm dia GI nipple IS 1239 (Part-II/1992 )

1

322

322.9

... More
100mm dia GI Socket IS 1239 (Part-II/1992 )

6

2115

352.65

... More
Cost of 100 mm dia MS T/W Clamp

1

818

818.81

... More
Cost of 100 mm dia C.I Sluice Valve

1

6897

6897.12

... More
50 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.

1

2479

2479.58

... More
Cost of 160mm x 160mm x 160mm HDPE Equal Tee

6

5838

973

... More
Cost of 160 mm dia HDPE End cap

7

826

118

... More
Cost of 160 mm dia HDPE tail paice

3

990

330

... More
Cost of 160 mm dia HDPE Flange

3

1419

473

... More
5/8 x3" Nut bolt & Foundation Nut bolt as per IS specification

5

385

77

... More
1/8" thick Rubber Insertion as per IS specification

2

2217

1108.97

... More
Cost, supplying of 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed brand including all cost, conveyance, cess etc complete but excluding cost of GST

16

79344

4959

... More
cost of 160mm×110mm dia PVC reducing socket.

1

191

191

... More
Cost of 110mm dia PVC FTA

1

127

127

... More
Cost of 150mm dia C.I. Butter Fly Valve BS:5155/15: Kirloskar or equivalent make 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed including all cost, conveyance, cess etc complete but excluding cost of GST (As per S/R 2022)

1

10252

10252

... More
Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp

1

14878

14878

... More
63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.

1

3141

3141

... More
3 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming.

25

2800

112

... More
2.50mm2 Submerssible (3 Core) Flat Cable ISI mark of reputed brand of ISI specification including all cost, conveyance, cess etc complete but excluding cost of GST

84

7896

94

... More
Cost of Wiring of Pump Chamber

1

3000

3000

... More
Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAAC , 11 KV "V" Cross arm, with required No.of 11 KV T & C Disc. Insulators in tension point & 11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc. including cost of all materials, labour transportation,inspection & commissioning etc. complete.

0.15

108426

722840

... More
Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25 KVA S/S, G.I.pipe earthing with 25X5mm G.I.Flats including cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, barbed fencing ( size (15'x10') with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.

1

310000

310000

... More
Construction of boundry wall fancing ( size (15'x10') with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc for substation as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.

1

41713

41713

... More
Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduite pipe, No.6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation including fixing of TD cable inside the earth trench as per direction of Engineer-in-charge..

1

3000

3000

... More
Electrical Earthing with digging earth pit of size (2 ft X 2 ft X 3 ft ) and using 1/2 '' G.I pipe ,No -6 G.I wire ,cable socket ,Flange , carcoal, salt etc. as per the direction of the Engineer-incharge.

2

5000

2500

... More
4.0 mm 2 PVC Single core Copper Wire

12

684

57

... More
Drilling a perfect vertical bore of 450mm dia up to specified depth below ground level in alluvial soil starta by mud rotary Rig , drilling as required to suit the site condition as per direction of Engineer -in-incharge including supply of Rig with its accessories tools and plants and all consumable etc. for a finished bore of 450mm dia suitable for lowering of 200mm dia ASTM Schedule-80 PVC housing & slotted pipe. 0 Mtr to 30mtr

30

31800

1060

... More
31 Mtr to 60mtr

30

34350

1145

... More
61 Mtr to 90 mtr

30

38100

1270

... More
91 Mtr to 100 mtr

10

13550

1355

... More
b)Lowering of 200 mm dia ASTM schedule-80 PVC casing and slotted pipe, cone,nipple etc.as per the necesscity & fitted and fixed up in perfectly vertical position and keeping the top of the casing pipe threaded1 Mtr. above the ground level, including plugging the tube well to prevent entry of foreign materials.

100

8500

85

... More
a)Cost of 200 mm dia PVC ASTM (D) Sch. 80 casing pipe of reputed make as per ASTM(D) 1785/2004 with Manufacture name should prominently be marked with CIPET test certification in the body of the pipe in indelible ink or stenciled to the certification of Engineer-in-Charge, including Trasnportation to site, etc. 0 to 150Mtr = 150Mtr.

100

165907

1659.07

... More
(b) (iv)Cost of 200 mm dia PVC Cone

1

977

977.68

... More
(c)Cost of 200 mm dia PVC end cap

1

733

733

... More
d) Cost of 200 mm dia PVC threaded nipple

1

703

703

... More
(e) (vi)Cost of slotting charges of 200 mm dia PVC (ASTM-D) Sch-80 pipe-

24

9235

384.81

... More
f) Graded and washed gravel of " B " grade

13

74931

5763.98

... More
g) Movement of rig

40

800

20

... More
h)Operation of 5 HP Pump

20

1500

75

... More
i) Bentonite powder(Drilling Mud)Type-II high grade confirming to IS No.6186/86

25

12398

495.92

... More
Cleaning and developing the tube well using their own compressor having 250/300 CFM at 10.5Kg/cm2 continuously worked till clear and adequate discharge is obtained from the well including supply and use of all necessary equipment and labour as per the direction of the Engineer-in-Charge.

20

24500

1225

... More
Labour Charges for Site clearance

1

2020

2020

... More
Loading and Unloading of Materials

1

1515

1515

... More
Excavation of mud pit

1

2020

2020

... More
Water Sample test if required

1

1200

1200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.