Odisha Industrial Infrastructure Development Corporation Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Industrial Infrastructure Development Corporation - IDCO Tender

Electrical and Electronics
Eprocure
Opening Date23 Dec 2022
Closing DateCancelled
Tender Amount₹ 7,01,46,621 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
.... do ..... of RMU 33kV 4-WAY 630A (2ISLTR+2 BKR) (LLVV) with AUX protection.

2

-

-

... More
11kV Equipment (Indoor Type)

-

-

-

... More
Supply,Installation,Testing & Commissioning of 30kV, 10kA, Metal Oxide, Class-2 (Station Class), Surge Arrester (for 33kV Incoming Line, HT side of 2nos. Power Transformers and 33/0.433kV Station Transformer) - Outdoor Type with Surge Counter with SCADA Compatibility, complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

6

-

-

... More
...do.... of 12kV, 10kA, Metal Oxide, Class-2 (Station Class), Surge Arrester with out surge counter( For Transformers & Out Going Feeders) - Outdoor type.

6

-

-

... More
...do.... of 11kV Indoor Air Insulated switchgear Panel consisting of Breaker-1250A, Busbar-2000A(Copper) & CT (800-400/1-1-1A) Horizontal draw type for Transformer Protection and Differential Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel

2

-

-

... More
...do.... of 11kV Indoor Air Insulated switchgear Panel consisting of Breaker-630A, Busbar-1250A (Copper), CT (400-200/1-1-1A) for Feeder protection Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel.

4

-

-

... More
...do.... of 11kV Bus-Coupler Indoor AIS Panel consisting of Breaker-630A, Bus-bar-1250A (Copper), Relay, CT .Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel.

1

-

-

... More
...do.... of 11kV, 2 Core, Single Phase, IVT (Inductive Voltage Transformers)(11/√3 kV / 110/√3-110/√3V), 3nos in a set, in a separate draw out chamber with Digital Voltmeter inside Control Room separately for Bus-1 & Bus-2 plug in type with dis-connector.

2

-

-

... More
SCADA

-

-

-

... More
Supply ,Installation,Testing & Commissioning of complete SCADA system for Primary Substation complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

1

-

-

... More
Transformer

-

-

-

... More
Supply,Installation,Testing & Commissioning of 5.0 MVA, 33/11kV Power Transformer DYn11 (Outdoor Installation) with Accessories with SCADA Compatibility, complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

2

-

-

... More
..........do..............of 100 kVA 33/0.433kV Energy efficient Station Transformer along with all HT & LT termination.

1

-

-

... More
Substation Earthing System GI

-

-

-

... More
Supply,Laying & Commissioning of Earthing Conductor 75X10 mm (5.89 Kg/Mtr.) GI Flat for laying (spacing maximum 2m both ways) complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

5301

-

-

... More
....do.......of 50X6 mm (2.4Kg./Mtr.) GI Flat for Raiser from the burial earth mat to equipment, structure etc.)

720

-

-

... More
Supply,Installation,Testing & Commissioning of Earthing Device & Associated Accessories (Heavy duty GI Perforated Pipe of ID=40mm & OD=50mm with 3000mm long for treated Earth Pit) complete (with supply of all required materials such as Salt, Charcoal, GI Nuts-Bolt-washer, construction materials for chamber & cover etc.) in all respect with earth chamber & cover as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC. (Each pit resistance will be measured and recorded and shall be as per IS)

40

-

-

... More
33kV, 11kV and Station Trf Structure

-

-

-

... More
Supply & Erection of (125x70x5) mm RS GI joist 5Mtr (13.3kg / Mtr) (04 nos for one Power Transformer) for supporting of 33kV Cable & 11kV cable (Unit Wt=0.0665 MT) & 10 mm thick MS plate size 250X250 mm at the bottom of the RS Joist duly welded & the MS plate to be suitably grouted to the floor for the rigidity, complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

532

-

-

... More
...........do..........of (100 x 50 x5) mm GI Channel (9.56kg / Mtr) (2Mtr - 06 nos for one Power Transformer) for supporting of 33kV & 11kV power Cable (Unit Wt=0.01912 MT)

229.44

-

-

... More
Supply & Fixing of GI Nuts & Bolts etc. for column and beam & Equipment Structures

500

-

-

... More
Supply & Erection of GI Pipe of dia. 150mm, Class-B

150

-

-

... More
Supply & Laying of High Density Polyethylene (HDPE) pipe 160 mm diameter.

0.01

-

-

... More
Supply,Installation,Testing & Commissioning of LTDB for 100kVA, 33/0.433kV Station Transformer with SCADA Compatibility, complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

1

-

-

... More
..............do............ of 8way LDB with accessories.

2

-

-

... More
33 and 11 kV Power and Control, XLPE cables

-

-

-

... More
Supply,Laying, Testing & Commissioning of 33kV, 1Core, 400sqmm, XLPE insulation (extruded type) ,(Armoured), A2XFY UG cable (with one single 1core, 400sqmm, XLPE cable as spare) in trefoil formation by open trench method, complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

2

-

-

... More
....do.......... of In-door termination kits Heat Shrinkable type suitable for 33kV, 1Core, 400sqmm, HT UG Cable kits for 1Core

52

-

-

... More
....do.......... of Outdoor termination kits Heat Shrinkable type suitable for 33kV, 1Core, 400sqmm, HT UG cable kits

24

-

-

... More
............do............ of 11kV, 3core, 400sqmm, aluminium, XLPE insulation, A2XFY armoured (extruded type) UG cable by open trench method.

1.5

-

-

... More
............do............ of Indoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set)

16

-

-

... More
............do............ of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, aluminium UG cable kits for 3Core (Set)

16

-

-

... More
Supply,Laying, Testing & Commissioning of Control Cables (Copper Armoured) complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

-

-

-

... More
4 Core x 2.5 mm2

0.7

-

-

... More
7 Core x 2.5 mm2

0.7

-

-

... More
10 Core x 2.5 mm2

0.5

-

-

... More
12 Core x 2.5 mm2

0.5

-

-

... More
1 Core x 16 mm2 Aluminium cable from Battery to Battery Charger & Battery Charger to DCDB

0.3

-

-

... More
Supply & Laying of 1.1 kV XLPE Power Cables complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

-

-

-

... More
XLPE 3 1/2 Core x 120 mm2 ( for Station Transformer output )

0.15

-

-

... More
XLPE 3 1/2 Core x 95 mm2 ( for Oil Filtration Machine Connection )

0.1

-

-

... More
XLPE 3 1/2 Core x 25 mm2 ( for Switchyard Lighting )

0.3

-

-

... More
XLPE 4 Core 16 mm2 ( for Switchyard Lighting )

0.3

-

-

... More
XLPE 2 Core 16 mm2 ( for Switchyard Lighting )

0.3

-

-

... More
Battery & Battery Charger

-

-

-

... More
Supply,Installation, Commissioning , Wiring & Testing of 48 V, 100 AH, maintenance free VRLA( Valve Regulated Lead Acid) Battery (Set. 4 Nos of 12V Battery with 150AH), complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

1

-

-

... More
....do........ of 48V, Float cum Boost Battery Charger (15 A float charging, 20 A boost charging)

2

-

-

... More
Sub-station Lighting And Fire Fighting System with complete wiring/cabling

-

-

-

... More
Supply,Installation & Commissioning of Sub-Station Switchyard Lighting , Control Room Lighting (internal & external) complete as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.(it includes supply of fixtures & Lamps (LED); 120W, 100W with switch gear, GI tubular poles, GI Conduit, cables, Copper wires swith/plug, DBs etc., Tube fittings, fans etc as per the requirement -maintaining suitable/required Lux levels complete.

1

-

-

... More
Supply,Installation, Commissioning & Testing of 1.5 Ton capacity Split Air Conditioning units with Remote control facility: Including supply of split Air conditioner 5 Star rated, voltage stabiliser, control boxes etc. for completing the A.C scheme. (As per specification) for control room, complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

4

-

-

... More
.......do....... of 1400 mm sweep 250Volt A/C Celling Fan

5

-

-

... More
.......do....... 300 mm sweep 70W A/C Exhaust Fan ( for Battery room and Toilet )

4

-

-

... More
Fire Detection Alarm System

-

-

-

... More
Supply,Installation,Testing & Commissioning of Main Fire ALARM Control Panel (Ul /FM /Ulc/Vds Approved),Intelligent Addressable Modular Fire Alarm Control Panel based on 32 bit microprocessors including the following as per specification.,(A) Battery charger,(B) SMF(sealed maintainance free) Batteries for 72 Hrs. back-up,(C) Enclosure,(D)min.240 character LCD display,( Other specification as mentioned),(E) The panel should be modular,decentralized, with CPU /master control unit, loop cards, relay and interface card by means of duplicated electronics means hardware redundancy with full functionality.(F) The panel must provide MODBUS/ RS485 port for integration with SCADA.(G)The loop should be capable to have at least 50 elements / devices, complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

1

-

-

... More
.......do.......... of Intelligent Addressable multi sensor Detector- (Smoke + Fixed Tempt. + Rate of rise tempt.) For ceiling (UL /FM /ULC/Vds Approved) inclusive of base and other installation accessories. (must have inbuilt short circuit isolator)

6

-

-

... More
.......do.......... of Intelligent Addressable multi sensor Detector- (Smoke + Fixed Tempt. + Rate of rise tempt.) For trench (UL /FM /ULC/Vds Approved) inclusive of base and other installation accessories. (must have inbuilt short circuit isolator)

2

-

-

... More
.......do.......... of Response Indicator ( Twin LED transparent type)

2

-

-

... More
.......do.......... of Addressable manual Call Point (must have inbuilt short circuit isolator,) (UL /FM /ULC/Vds Approved)

1

-

-

... More
.......do.......... of Electronic Hooter/Multi tone sounder (must have inbuilt short circuit isolator,) (UL /FM /ULC/Vds Approved) Indoor type.

1

-

-

... More
Supply,Laying & Testing of 2 Core X 1.5 sq.mm copper conductor, armored, RED colour FRLS PVC sheathed signal Cable confirming to IS standards and specifications

150

-

-

... More
Supply,Laying & Testing of 4Cx2.5sqmm copper armoured FRLS cable confirming to IS standard with accessories (Gland, lug, saddle, etc.)

15

-

-

... More
Supply & Installation of steel wire reinforced flexible conduit pipe (16MM) with all accessories.

15

-

-

... More
Supply & Installation of Surge Arrester

1

-

-

... More
Supply & Installation of Lightning Rod in Top of PSS Building.

1

-

-

... More
Fire Fighting System (portable and wheel mounted sets for control room);

-

-

-

... More
Supply & Installation of Foam type- 5 Ltrs

2

-

-

... More
Supply & Installation of CO2 - 4.5 Kgs

2

-

-

... More
Supply & Installation of Dry powder 4.5 Kg

2

-

-

... More
Supply & Installation of Fire Bucket with Stand (4nos. in each Stand)

4

-

-

... More
AC & DC System for Auxiliary supply complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

-

-

-

... More
Supply,Installation,Testing & Commissioning of Main Lighting Distribution Board (as per specification),complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

1

-

-

... More
..........do........... of Indoor Lighting Distribution Board as per specification

1

-

-

... More
..........do........... of Receptable Panel near Power Transformer

1

-

-

... More
DC System

-

-

-

... More
Supply,Installation,Testing & Commissioning of 48 V DC Distribution Board (as per specification),complete in all respect as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC.

2

-

-

... More
.........do........... of Water Cooler with water Purifier System

1

-

-

... More
.........do........... of Maintenance Testing Equipment as per Technical Specification

1

-

-

... More
.........do........... of Tools and Plants (T&P's) Requirement as per Technical Specification

1

-

-

... More
Supply & Commissioning of Office Furniture as per Technical Specification,complete in all respect as required & as per GTP/drawing approval by TPSODL & direction of EIC.

1

-

-

... More
Supply & Installation of Materials for Installation of Power Transformer on Plinth (complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC. )

-

-

-

... More
90 lb Rail 5.4 mts ( 2.7x2) 44.62 kg per mtr / Transformer each (Unit Wt=0.240 MT)

2

-

-

... More
(500x500x10) mm GI plate 6 nos / Transformer each (Unit Wt=0.013 MT)

6

-

-

... More
(65x65x5) mm GI angle of 5.4 mts length.4.9 kg/mtr. / Transformer each (Unit Wt=0.026 MT)

2

-

-

... More
Construction of Cable Trench :

-

-

-

... More
Supply of all required materials and making of 2 tier 2 rows U-Type RCC Cable trench with M-20 Grade concrete: The internal width 2000 mm, depth 1005 mm, with 75X75X6 mm support angles fixed RCC wall of 175 X 175 mm, Raft of 175mm & with ladder type cable tray (45X45X5)mm two angles at both side having welded flats of 25X5 mm at a gap of 150mm) for Power & control Cable with RCC Trench Cover Slab as per technical Specification, approved drawing and Direction of Engineer Incharge. Complete work including earth work in excavation in all kind of soil & rock and refilling the cavity by selective soil, leveling the surface around the pit with disposal of surplus earth complete in all respect as required & as per technical specification & GTP/Drawing approval by TPSODL & direction of EIC.

71.85

-

-

... More
......do.......... of Chequered plate 1000X300X5.6mm thick for Cable Trench in side Control Room 12 Mtr.

640

-

-

... More
33KV Line DP-2No's

-

-

-

... More
Supply, Fabrication & Installation of 13 Mtr. H Pole, including excavation, refilling, 1:1.5:3 , M20 Grade cement concreting of size - 500(B)x500(W)X2200(H) , and couping of 500(B)x500(W)x450(H) and and zebra painting (In Black & Yellow Strips) complete in all respect as required & as per technical specification & GTP/Drawing approval by TPSODL & direction of EIC.

4

-

-

... More
Supply, Fabrication & Installation of GI Top Channel 100X50X6mm@9.56 KG/MTR. X (4.3 x2)

164.43

-

-

... More
Supply & Installation of Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)/DP

7.93

-

-

... More
Supply,Installation & Fabrication of Insulator Support Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 1 no's channel required =( 1x7.14x4.3)

61.4

-

-

... More
Supply,Installation & Fabrication of Isolator Support Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 2 no's channel required =( 2x7.14x4.3)

122.81

-

-

... More
Supply,Installation & Fabrication of Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 4 no's channel required =( 4x7.14x4.3)

245.62

-

-

... More
Supply,Installation & Fabrication of 50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 4.927 mtr., 4 nos angle required = (4*4.5*4.927)

177.37

-

-

... More
Supply,Installation & Fabrication of Isolator Operating Down Pipe Support Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 1x7.14x0.8)

11.42

-

-

... More
Supply,Installation & Fabrication of Down Pipe Diagonal Support Angle, 4.5Kg./mtr., each angle length 0.388mtr., 1 nos angle required = (1*4.5*0.388)

3.49

-

-

... More
Supply,Installation & Fabrication of Down Pipe Base Support Angle, 4.5Kg./mtr., each angle length 0.34mtr., 1 nos angle required = (1*4.5*0.340)

3.06

-

-

... More
Supply,Installation & Fabrication of Isolator Support Side Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 0.5 mtr., 2 no's channel required =( 2x9.56x0.5)

19.12

-

-

... More
Supply of H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.511 Mtr. Length, 2 no's qty. required ( 1 Pair)

4

-

-

... More
Supply of H.T. Stay set (Complete )

4

-

-

... More
Supply of H.T. Stay Insulator Type-C (2 No's.)

8

-

-

... More
Supply of 7/8 SWG Stay Wire 15kg /stay

60

-

-

... More
Fixing of complete 33KV stay set including 0.5Cum cement concrete foundation 1:2:4 size (500mm x 500mm x 800mm)

4

-

-

... More
Supply,Installation,Testing & Commissioning of Earthing Device & Associated Accessories (Heavy duty GI Perforated Pipe of ID=40mm & OD=50mm with 3000mm long ) complete (with supply of all required materials such as Salt, Charcoal, GI Nuts-Bolt-washer, construction materials for chamber & cover etc.) in all respect with earth chamber & cover as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC. (Each pit resistance will be measured and recorded and shall be as per IS)

4

-

-

... More
Supply & Installation of 50x6mm GI Flat for earthing, 2.36kg/mtr., (15 Mtr. For L.A, 4 Mtr for Isolator Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 24x2.36

113.28

-

-

... More
Supply & Installation of Danger Plate, 2 no's.

4

-

-

... More
Supply & Installation of Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.2

-

-

... More
Supply & Installation of GI barbed wire anticlimbing device (3 Kg. Per support)

12

-

-

... More
Supply & Installation of Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

4.81

-

-

... More
Supply,Installation,Testing & Commissioning of Lightning Arrester(30KV,10KA) (Station Class,class-2)complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

6

-

-

... More
.........do......... of 33 KV 630 AMP Double break (Turn & twist center rotating) isolator with earth switch with Pl(Polymer)

2

-

-

... More
.........do......... of 33KV pin insulator polymer

6

-

-

... More
.........do......... of H W fitting(B&S) 90KN,4 Bolt

12

-

-

... More
.........do......... of 33KV Polymer Disc Insulator (90KN- 120KN) along with Hardware fitting.

12

-

-

... More
.........do......... of PG Clamp for 232 sq.mm AAA conductor

12

-

-

... More
.........do......... of GI Nut , Bolt & Washer of different sizes (22.15 Kg each DP with Isolator)

44.3

-

-

... More
11kV Line DP-4Nos

-

-

-

... More
Supply, Fabrication & Installation of WPB 160x152 (11Mtr. Long, 30.44KG/Mtr.) with excavation of pole pit in all kind soil, & providing & laying of 1:1.5:3 , M20, concrete of size - 500(B)x500(W)X1800(H) , and cooping of 500(B)x500(W)x450(H), Scope of work also includes refilling, water-ramming & 5 days curing and zebra painting (In Black & Yellow Strips/Zebra)complete in all respect as required & as per technical specification & GTP/ Drawing approval by TPSODL & direction of EIC.

8

-

-

... More
Supply,Installation & Fabrication of Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no's channel required =( 2x9.56x3)

229.44

-

-

... More
Supply,Installation & Fabrication of Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

15.86

-

-

... More
Supply,Installation & Fabrication of Isolator switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no's channel required =( 7.14x3x2)

171.36

-

-

... More
Supply,Installation & Fabrication of Isolator Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

26.77

-

-

... More
Supply,Installation & Fabrication of Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

22.85

-

-

... More
Supply,Installation & Fabrication of Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 1.66 Mtr., 4 no's channel required =( 7.14x3x4)

342.72

-

-

... More
Supply,Installation & Fabrication of 50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)

252.86

-

-

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

8

-

-

... More
H.T. Stay set (Complete )

8

-

-

... More
H.T. Stay Insulator Type-C

8

-

-

... More
7/10 SWG Stay Wire 15kg /stay

120

-

-

... More
Fixing of complete 11KV stay set including 0.5Cum cement concrete foundation 1:2:4 size (500mm x 500mm x 800mm)

8

-

-

... More
Supply,Installation,Testing & Commissioning of Earthing Device & Associated Accessories (Heavy duty GI Perforated Pipe of ID=40mm & OD=50mm with 3000mm long ) complete (with supply of all required materials such as Salt, Charcoal, GI Nuts-Bolt-washer, construction materials for chamber & cover etc.) in all respect with earth chamber & cover as required & as per technical specification & GTP/drawing approval by TPSODL & direction of EIC. (Each pit resistance will be measured and recorded and shall be as per IS)

8

-

-

... More
Supply & laying/Installation of 50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36

193.52

-

-

... More
Supply & Installation of Danger Plate, 2 no's.

8

-

-

... More
Supply & Installation of Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

2.41

-

-

... More
Supply & Installation of GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

24

-

-

... More
Supply & Installation of Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

9.63

-

-

... More
Supply,Installation,Testing & Commissioning of Lightning Arrester(11KV,10KA) (Station Class,class-2)complete in all respect as required & as per technical specification & GTP approval by TPSODL & direction of EIC.

12

-

-

... More
......do...... of 11KV 400 AMP isolator with earth switch with PI(polymer)

4

-

-

... More
......do...... of 11 KV pin insulator polymer

12

-

-

... More
......do...... of H W fitting (B&S) 70KN, 3Bolt

24

-

-

... More
......do...... of Disc insulator (B&S) 70 KN polymer

24

-

-

... More
......do...... of PG Clamp for 100 sq.mm AAA conductor

24

-

-

... More
......do...... of GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)

54.87

-

-

... More
Supply & Painting the Poles with Black paint (4Ltrs), Yellow paint (8 ltrs) in Black & Yellow strip complete as required & as per specification.

1

-

-

... More
PART-B (Civil Works)

-

-

-

... More
Civil Works complete in all respect as required & as per technical specification & GTP / Drawing approval by TPSODL & direction of EIC.

-

-

-

... More
Contour survey , plotting the contour on graph sheet and marking the finished ground level

1224

-

-

... More
Cutting for Levelling and disposal of excess earth either in low laying area in sub-station or outside.

143

-

-

... More
Filling of S/S area with borrowed earth (rolling & compacting of filled up soil before taking measurement).

2320

-

-

... More
OUT DOOR DRAIN to DISCHARGE SWITCHYARD/ WATER FROM WASH BASIN AND CONTROL ROOM ROOF (10 mts

-

-

-

... More
Excavation in all type soil (1.35x10x0.7)

9.45

-

-

... More
PCC (1:3:6 ) (1.35x10x0.1)

1.35

-

-

... More
PCC ( 1:2:4 ) (0.3x10x0.05)

0.15

-

-

... More
Brick Masonary with cement mortar ( 1:5 ) (0.25x10x0.925+1/2x0.15x0.93x10)+(0.25x10x0.925)

5.32

-

-

... More
Plastering with Cement mortar(1:6) ( 2x0.25x10+2x0.925x10+1x0.925x10+1x1.0x10 )

42.75

-

-

... More
Switch Yard and COMPOUND WALL as per Drawing Schedule and Specification. For PILE Foundation for SBC Upto 10

-

-

-

... More
Construction of Compound-wall (with RCC column & beam with M-20 Grade concrete ) along the property line of the sub-station as per technical specification and instruction of the Engineer in Charge.(the size of the bricks shall be 250mm having 1st class Fly-ash brick having compressive strength with 75kg/cm2). This also includes excavation in all types of soil or rocks, backfilling ,and disposal of excess earth . (Brick works rested on RCC Beam and RCC Column & footings , including Cement Plastering, Cement wash, Wall Painting two coats with weather coat. Provision of the boundary wall Fencing with M.S Grill of 700 mm height fixing at the top of the wall. It includes supply of all the materials & two coats of synthetic enamel paintings after primer application of the fencing .

140

-

-

... More
Switch Yard GI Chain Linking Fencing with 2 Mtr Height.

60

-

-

... More
Power Transformer Foundation / One (5 MVA)

-

-

-

... More
Excavation in all type soil per Tfr.(3X3X1.1 mtr)

19.8

-

-

... More
PCC (1:3:6 ) per Tfr.(3X3X0.075 mtr)

1.35

-

-

... More
RCC ( 1:1.5:3 ) per Tfr. As per drawing

10.52

-

-

... More
RRHG stone grouting with sand per Tfr.

9

-

-

... More
Construction of 100kVA 33/0.4 kV station Trf. Plinth

-

-

-

... More
Excavation in all type soil (2.5X2.5X0.750 mtr)

4.69

-

-

... More
PCC (1:3:6 ) (2.5X2.5X0.075 mtr)

0.47

-

-

... More
RCC ( 1:1.5:3 ) (1.5X1.5X0.1 mtr)

0.23

-

-

... More
Brick Masonary work (2.5x2.5x.925+2x(.5 x1.5x2.25) (1:5)

61.19

-

-

... More
Cement Plastering (1:6) (1.5x2.25x4)+(1.5x1.5) 20mm thick

15.75

-

-

... More
Construction of oil sump pit for Transformer (1.6 X 1.6 X 2.3 )

-

-

-

... More
Excavation of Earth(2.0x2.0x2.1)

8.4

-

-

... More
PCC (1:3:6) 2X2X0.1

0.4

-

-

... More
RCC(1:1.5:3) 1.6X1.6X0.1 for Top Slab

0.26

-

-

... More
Brick Masonary work(2x2.1+2x1.6)x0.25x2.3 (1:5)

4.26

-

-

... More
Cement Plastering (1:6) 2.3 ( 4x2.1+ 4x1.6 )+ 1.6x1.6

36.6

-

-

... More
Drainage for Oil sump pit with 250 dia hume pipe

24

-

-

... More
ROAD (6 Mtrs wide) Length of the road 20 mtrs as per Drawing Schedule- OPTCL/CIVIL/11-REV-B.

-

-

-

... More
Excavation in all type soil 0.5mx1mx6m

60

-

-

... More
Boulder Packing 0.5mx1mx5m

60

-

-

... More
Water base course -I 0.075mx1mx5m

9

-

-

... More
Water base course -II 0.075mx1mx5m

9

-

-

... More
PCC ( 1:2:4 ) 0.1mx1mx5m

12

-

-

... More
(125x70x5) mm RS GI joist 5Mtr ( STATION) as per Drawing Schedule- OPTCL/CIVIL/2-REV-B.

-

-

-

... More
Excavation with back filling L 1m x W 1 x D 2

8

-

-

... More
PCC (1:3:6)

0.4

-

-

... More
RCC (1:1.5:3)

12

-

-

... More
Baffle Wall

-

-

-

... More
Excavation with back filling 4.2mx0.75mx0.5m

1.58

-

-

... More
PCC 1:3:6 4.2mx0.75mx0.1m

0.32

-

-

... More
RCC 1:1.5:3 0.75x3.8x0.2+0.5x3.4x0.2+2.5x3x0.15

5.8

-

-

... More
PCC (1:4:8 ) With cement For S/S area(75 mm) per Sq. mts.( (8x16x0.075)

9.6

-

-

... More
Metal Spreading 100 mm. per Sq. mts. Area of spreading.

12.8

-

-

... More
Switchgear Cum Control Room (22x10Mts) (column & beam based) (as per specification & Inclusive of doors, windows, collapsible gate, PHD fittings, electrification, inner cable trench, Two nos main doors with concrete pillars, beams) etc. as per TPSODL approved Technical specification & Layout Drawing complete.

-

-

-

... More
Switchgear Cum Control Room For Pile foundation in FLOOD AREA (with SBC upto 10)

-

-

-

... More
Boring and casting 300 mm dia single under reamed pile of 5.00 m. long with R.C.C. M-20 using 20 mm down graded chips with cost of all materials, labours, T&P etc. & all other machinaries required for the work etc. Complete in all respect as per latest specification & direction of the Engineer in charge.

252

-

-

... More
Earth work in excavation of foundation trenches in all kinds of soil including moorum, stony earth and earth mixed with boulders except sheet rock and boulders requiring blasting including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site within initial leads and lifts, including shoring, shuttering & dewatering (if required) with cost of labour,cess, hire & running charges of water pumps sundries , T & P & all other machinaries required for the work etc. Complete in all respect as per latest specification & direction of the Engineer in charge.

470.8

-

-

... More
Supplying and filling in foundation and plinth with good river sand well watered and rammed in layers not exceeding 23 cm in each layer including all leads and lifts, cost of all materials, labour,cess, sundries, T&P required for the work etc. Complete in all respect as per latest specification & direction of the Engineer in charge.

791.6

-

-

... More
Providing and lying plain cement concrete of proportion (1:3:6) in foundation and plinths using approved quality cement , 40 mm. size black hard crusher broken granite stone metal and screened, washed sharp sand for mortar of approved quality and from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, cess, sundries, T&P & all other machinaries required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump etc. Complete in all respect as per latest specification & direction of the Engineer in charge.

156.8

-

-

... More
K.B. Brick masonary in cement mortar (1:6) using the bricks of size 10" x 5" x 3" of crushing strength not less than 100 kg / centimeter square with dimensional tolerance 3% after immersing the bricks for 6 hours in water before use including hoisting to required height placing in position scaffolding, splays cutting, circular moulding, corbelling, chamfering and similar such type of work watering and curing etc. including cost, conveyance, royalty, cess, and taxes of all other materials machinaries scaffolding all labour T&P articles required for the work etc. complete in all respect as per the latest specification confirming to relevant IS Specification and direction of the Engineer-in-charge.

-

-

-

... More
In Foundation and Plinth

108

-

-

... More
Ground Floor

222.8

-

-

... More
RCC work M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 200 Kg./ Sqcm.in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S.456 and I.S 516 using 12 mm. to 20 mm. size black hard crusher broken granite stone chips, screened and washed sharp sand for mortar of approved quality from approved quarry, to be mixed in concrete mixture with approved quality cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes and cess of all materials, cost of all labours, sundries, T&P & all other machinaries required for the work but excluding cost and conveyance of M.S. or Tor steel and binding wires etc. Complete in all respect as per latest specification & direction of the Engineer in charge.

-

-

-

... More
Pile cap & Grade beam

300

-

-

... More
R.C.C. wall

70.8

-

-

... More
Plinth Beam

24.4

-

-

... More
Column & Beam- Ground Floor

144

-

-

... More
Lintel-Ground Floor

8.8

-

-

... More
65mm thick R.C.C.Chajja- Ground Floor

88.4

-

-

... More
Roof slab - Ground Floor

147.2

-

-

... More
Staircase- Ground Floor

23.6

-

-

... More
Cutting, Straightening coiled or bent up M.S. rods or Tor steel welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S. rod / Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost etc. complete in all respect as per direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

72

-

-

... More
Supplying, fitting and fixing vitrified tile 60x60cm plain Ivory 8 to 10 mm thick in floors of approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filling joints with epoxy grout of approved quality including cost of all materials, takes labour T&P etc. required for the work etc. complete in all respect as per the latest specification and direction of the Engineer-in-charge.

416

-

-

... More
Supplying, fitting and fixing vitrified tile 60x60cm plain Ivory 8 to 10 mm thick in dado of approved make with application of polymer modified cement based water resistant adhesive bed of required thickness of 10mm and filling joints with epoxy grout of approved quality including cost of all materials, takes labour T&P etc. required for the work etc. complete in all respect as per the latest specification and direction of the Engineer-in-charge.

36.8

-

-

... More
Supplying, fitting and fixing Floor tile of size 40cmx40 cm / 30cmx30cm in floors on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles of required thickness of approved quality including cost of all materials, takes labour T&P etc. required for the work.etc complete in all respect as per the latest specification and direction of the Engineer-in-charge.

20.4

-

-

... More
Providing fitting fixing Glazed /Ceramic tiles of size 20cmX30cm & 6.5 to 6.7mm thick of size up to 0.10sqm in wall dados skirting and on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including cost of precast tiles etc. complete in all respect as per the latest specification and direction of the Engineer-in-charge.

107.2

-

-

... More
Supplying, fitting and fixing 5"x2½" size Dressed seasoned Sal wood chaukaths including cost, conveyance royality taxes of all materials. labour, all other machinaries, T & P articles required for the work complete in all respect as per the direction of the Engineer-in-Charge.

1

-

-

... More
Supplying, fitting and fixing 30mm/32mm flush door shutter (Non-Sal hard wood frame fixed with 4mm BWR ply on both sides of frame.including cost conveyance royality taxes of all materials. labour, all other machinaries, T & P articles required for the work complete in all respect as per the direction of the Engineer-in-Charge.

57.6

-

-

... More
Providing and fixing of sliding windows of approved make to be febricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick "D" quality, galvanized as per IS-277 with zinc of 120 Gm/ Sqm.) including cost conveyance royality taxes of all materials. labour, all other machinaries, T & P articles required for the work complete in all respect as per the direction of the Engineer-in-Charge. DOUBLE SHUTTER SLIDING WINDOW

124

-

-

... More
Providing and fixing of FRP door frame including cost conveyance royality taxes of all materials. labour, all other machinaries, T & P articles required for the work complete in all respect as per the latest specification and direction of the Engineer-in-Charge.

40.8

-

-

... More
Providing and fixing of FRP door shutter including cost conveyance royality taxes of all materials. labour, all other machinaries, T & P articles required for the work complete in all respect as per the latest specification and direction of the Engineer-in-Charge.

15.2

-

-

... More
Providing 16mm. thick cement plaster with cement mortar of mix (1:6) with approved quality cement with screened and washed sharp sand for mortar and finished smooth to the surface over brick work after racking out the joints including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties, cess, and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge

-

-

-

... More
Ground Floor

2499.6

-

-

... More
Providing 12mm. thick cement plaster with cement mortar of mix (1:6) with approved quality cement and screened and washed sharp sand for mortar and finished smooth to the surface over brick work after racking out the joints including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes, cess, of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charger in charge

-

-

-

... More
Ground Floor

1588.4

-

-

... More
Providing 12mm. thick cement plaster with cement mortar of mix (1:3) with approved quality cement with screened and washed sharp sand for mortar and finished smooth to the surface in ceiling and R.C.C. surface after chipping the surface in all floors including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties, cess, and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.

-

-

-

... More
Ground Floor

1603.6

-

-

... More
Providing and finishing the wall surface with two coat of cement wash including scaffolding, all labour, cost, conveyance, cess, taxes of all materials, T&P articles, brushes all other machineries required for the work complete in all respect confirming to relevant I.S. Specification and direction of the Engineer-in-Charge

-

-

-

... More
Ground Floor

5655.2

-

-

... More
Supplying fitting and fixing of M.S shutter made out of M.S Angle 40mmx40mmx6mmm, M.S.Flat 19 mm x 5 mm size, M.S. guide, top hood cover etc. as per design provided including cost, conveyance, royalities of all materials, cost of all labour, T&P articles required for the work etc. complete in all respect confirming to relevant I.S specification and direction of the Engineer-in Charge.

3166.8

-

-

... More
Supplying fitting and fixing of M.S grill made out of M.S M.S.Flat 19 mm x 5 mm size, as per design provided including cost, conveyance, royalities of all materials, cost of all labour, T&P articles required for the work etc. complete in all respect confirming to relevant I.S specification and direction of the Engineer-in Charge.

2848.4

-

-

... More
Wall painting 2 coats with acrylic distemper over one coat of wall primer of approved shade on new work to give an even shade in all floors at all height including scafolding cost of brushes including cost of paint cost conveyance royality of all materials labour,T&P articles required for the work etc. complete in all respect as per the latest specification and direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

3725.2

-

-

... More
Painting two coats with weather coat on exterior walls surface of approved quality and approved shade over a coat of primer in all floors at all height of approved quality and shade including cleaning and sand papering the surface and making the surface smooth with cost, conveyance, loading, unloading, and taxes of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work complete in all respect as directed by Engineer-in-charge

-

-

-

... More
Ground Floor

1930

-

-

... More
Painting two Coats with approved colour synthetic enamel paint on wood / iron work in all floors at all height including scafolding cost conveyance royality of all materials labour,T&P articles required for the work etc. complete in all respect as per the latest specification and direction of the Engineer-in-charge.

418.4

-

-

... More
Providing cement concrete (1:1.5:3) using 12mm size black hard crusher broken granite stone chips, screened & washed sharp sand for mortar of approved quality and from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, cess, sundries, T&P & all other machinaries required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump etc. Complete in all respect as per latest specification & direction of the Engineer in charge.

123.6

-

-

... More
Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.

68

-

-

... More
Providing and fixing M.S. fan clamp type-I of 16mm dia M.S. bar bent to shape with hooked ends in R.C.C. slab during laying including painting the exposed portion of loop as per standard design complete as directed by the Engineer-in-charge.

120

-

-

... More
Providing 12mm. thick cement plaster in cement mortar of mix (1:4) with neat cement punning with approved quality cement with screened and washed sharp sand for mortar and finished smooth to the surface in ceiling and R.C.C. surface after chipping the surface in septic tank including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties, cess, and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.

48.4

-

-

... More
Providing neat cement punning with approved quality cement finished smooth to the surface etc. complete with cost, conveyance, loading, unloading, royalties, cess, and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.

958

-

-

... More
40 mm thick grading concrete with cement concrete (1:2:4) using 12mm and down graded b.h.g. chips to the roof surface with water proofing cement compound finished smooth over RCC slab including hoisting and laying in position watering and curing for required number of days finished to smooth surface and desired slope including cost conveyance, royalty and taxes of all materials, labour T&P articles required for the work etc. complete in all respect confirming to relevant I.S specification and direction of the Engineer-in-Charge.

550.8

-

-

... More
P.H. Fitting (Internal & External) to Switch-Gear -Cum -Control Room

-

-

-

... More
Supplying all materials , labours , taxes and tools and plants for fitting and fixing of PVC pipes of following nominal bore conforming to ASTM-D-1785 (Schedule-80) including fittings and laying as per the site requirement etc., all complete including testing as per the direction and specification of Engineer-in-charge

-

-

-

... More
15 mm dia

15

-

-

... More
20 mm dia

20

-

-

... More
25 mm dia

15

-

-

... More
40 mm dia

20

-

-

... More
50 mm dia

20

-

-

... More
Supplying all material, labour , T&P & fitting ,fixing the following different water supply fittings of approved make with including supply of all necessary jointing materials etc. all complete as directed by the Engineer-in-charge.

-

-

-

... More
25 mm dia Ball valve

2

-

-

... More
50 mm dia Ball valve

2

-

-

... More
25 mm dia F.W. valve

2

-

-

... More
50 mm dia F.W. valve

2

-

-

... More
Supplying all labour T&P and cutting holes in brick masonry wall for taking pipes through and mending good the damages with supply of all required materials etc. complete as per the direction of the Engineer-incharge

-

-

-

... More
For 15mm to 50mm CPVC pipe to pass in 125mm to 250mm thick wall

10

-

-

... More
Supplying all labour T&P and materials and making grooves in brick walls vertically and horizontally to the required depth and width for fixing pipes & fittings of sizes 15mm dia to 25mm dia in the grooves, testing the pipe line against leakage, and filling the grooves with cement mortar(1:4) to bring the surface to original level including cost of mortars, curing and conveyance of materials etc. complete as per direction of the Engineer-in-charge.

10

-

-

... More
Supplying all materials , labour T&P and fittings of approved quality required for fixing of NP or CP Brass or GM fixtures of following sizes and specification with leak proof threaded joints tightened with spun yarn and white zinc or any tightened with spun yarn and white zinc or any including testing and rectification of detects, after testing complete as per direction of Engineer-in-charge.

-

-

-

... More
Bibcock

5

-

-

... More
Long Body Bibcock

2

-

-

... More
Pillar cock

2

-

-

... More
Angular stop cock

4

-

-

... More
Soap Holder

2

-

-

... More
Towel ring

2

-

-

... More
Toilet paper holder

2

-

-

... More
Glass self 22"

2

-

-

... More
Towel rail 24"

2

-

-

... More
Shower arm 190mm long light

2

-

-

... More
CP Grating

2

-

-

... More
Concealed stop cock

4

-

-

... More
Connecting Pipe

2

-

-

... More
Basin with pedestal

2

-

-

... More
Providing and fixing vitreous China water closet (European with seat and lid), of Cerra Cascade “CASINO”, CP brass buffers, 10 liter cascade dual flushing cistern hinges & rubber with fittings and brackets, 40 mm flush bend of CP brass, 20 mm overflow pipe with specials & mosquito proof coupling complete, painting on brackets and making good the walls and floors wherever required.

1

-

-

... More
Providing and fixing vitreous China water closet Indian type of Orissa pattern size (580mmx440mm) of approved quality with PVC Slimeline (Parryware make) 12.5 ltr capacity low level cistrn with hinges & rubber with fittings and brackets, 40 mm flush bend of CP brass, 20 mm overflow pipe with specials & mosquito proof coupling complete, painting on brackets and making good the walls and floors wherever required.

1

-

-

... More
Providing and fixing vitreous China water urinal of Cerra/Parry ware with fittings and brackets, flush bend of CP brass, and making good the walls and floors wherever required.

2

-

-

... More
Supply of all materials, labour, T&P , fitting and fixing in all floors fixed type bevelled plate glass mirror of size 600mm x 450mm x 5.5mm thick best Indian make ,supply of 13mm thick asbestos backing and CP Brass screw including cost conveyance, taxes of all materials complete as per specification and direction of Engineer-in-charge(Make-Modi Guard/Belgium)

2

-

-

... More
Supply of all materials, joining materials ,labour and T&P and laying UPVC SWR PIPES of Standard make with ISI Mark duly approved by the Engineer-in-charge including jointing, earthwork in excavation of trenches in all kind of soil to the required depth and refilling of pipe line trenches in 0.3048 mtrs layers with 300 mm deep sand around cushion duly watered and rammed or fixing to walls, floors with supply of necessary clamps, nails and cutting the pipe to length with wastage including supply of all Clamps, Clips, Endcaps & jointing materials etc., complete as per standard specification and direction of Engineer-in-charge.

-

-

-

... More
100mm dia ( ISI Marked )

10

-

-

... More
150mm dia ( ISI Marked)

25

-

-

... More
Supplying all materials, labour T&P for jointing of the UPVC SWR SEWER pipe fittings of standard make duly approved by the Engineer-in-charge with joining material etc. suitably required for fixing on 100mm dia soil waste pipe complete with requisite testing as directed by Engineer-in-charge.

-

-

-

... More
100mm dia "P" Trap

2

-

-

... More
100mm dia Bend Plain

3

-

-

... More
100mm Door Bend

3

-

-

... More
100 mm dia Single Junction with Door

3

-

-

... More
100 mm dia double Junction with Door

3

-

-

... More
100mm dia Terminal Guard

2

-

-

... More
100mm dia. Floor trap

3

-

-

... More
Supplying all materials, labor T&P for jointing of the UPVC SWR SEWER pipes & fittings of standard make duly approved by the Engineer-in-charge suitably required for fixing on 100mm dia soil waste pipe complete with requisite testing as directed by Engineer-in-charge.

-

-

-

... More
100mm Pipe

10

-

-

... More
Fixing of UPVC vent pipes Including labour & T&P all complete as directed by the Engineer-in-charge.

-

-

-

... More
100mm Pipe

4

-

-

... More
100mm Vent Cowl

2

-

-

... More
Supplying all materials labour T&P and constructing inspection chamber C.C.(1:4:8) on bed with hard stone metal size 40mm and 250mm K.B.Bricks work having crushing strength 75 Kg to 99 Kg/cm2 in cement mortar (1:4), R.C.C. roof slab with 500mm dia light pattern factory made SFRC M.H cover with frame, moulding and shaping the channel and benching with C.C. 1:2:4 with hard granite chips 12mm size, 12mm thick C.P 1:3 including cement punning inside, Cement plaster (1:3) outside the chamber, earth work in excavation in all kinds of soil and refilling the cavity around the chamber as per detail drawing & design and specification including cost, conveyance, taxes etc. all complete as directed by Engineer-in-charge.

-

-

-

... More
750mmx 750mm x450mm

1

-

-

... More
Providing and fixing 2000 litres capacity P.V.C Over head (Sintex make) tank with all piping and valve arrangement with all labour & materials ,including cost, T&P , scaffolding etc., complete as directed by the Engineer-in-charge.

-

-

-

... More
2000 Ltr Capacity

1

-

-

... More
Supplying all material, labour, T&P and constructing manhole chamber of size as mentioned below with 250mm nominal size K.B. Brick having crushing strength 75kg to 99kg /cm2 in CM 1:4 over a bed of 150mm thick C.C(1:4:8) using 40mm size HG metal, plastering with 12mm thick cement mortar (1:3) on internal and external surface, inside finish with neat cement punning, providing & fixing step iron of appropriate quality & size with 3 coats anticorrosive paint, RCC (1:1.5:3) cover slab using 20m & down size graded HG chips along with factory made reinforced concrete cover with frame including breaking of pipe line where ever necessary and earth work in excavation in all kind of soil & rock and refilling the cavity by selective soil, leveling the surface around the chamber with disposal of surplus earth if any to a distance of 50mt as per specification, design & drawing including cost of curing and all taxes , royality , cost , conveyance etc. all complete as directed by the Engineer-in-charge.

1

-

-

... More
Supplying all material, labour, T&P and constructing 1.80m dia x 2.60m deep soak way pit with dry brick walling upto 2.00m height and 1st class K.B. Brickwork in cement mortar (1:6) for the remaining 06.60m height at top, 12mm thick cement plaster (1:4) inside and outside , 100mm thick gravel backing in the rear of well staining, 125mm thick RCC cover slab fitted with with iron lifting handles including earth work in excavation in all kind of soil & rock and refilling the cavity by selective soil, leveling the surface around the pit with disposal of surplus earth if any to a distance of 50mt including cost of curing and all taxes , royality , cost , conveyance etc. all complete as directed by the Engineer-in-charge.

1

-

-

... More
Watering system like 150 mm dia, 100 Mtr deep bore well (PVC pipe to be used) 1 HP submersivele pump, switch yard water hydrant system for pouring water into the earth pits, tap for garden, including PVC pipes & other accessories required etc.

1

-

-

... More
Small wicket (GI) gate one in between Main Gate & Security shed & another in front of Customer Care room of size 1.5 mtr width X 2 mtrs height single leaf with locking arrangement etc. as per above.

2

-

-

... More
RRHG retaing wall with 1:5 cement mortar Considering 0.6 mt height of retaining wall above the existing ground level per Meter as per Drawing TOTAL 74 Mtrs

-

-

-

... More
Excavation in all type of soil( 0.8 Cum / Mtr)

105.6

-

-

... More
PCC (1:4:8) 200 mm thick. With cement ( 0.2 Cum / Mtr)

26.4

-

-

... More
PCC (1:2:4) 50 mm thick With cement ( 0.02 Cum / Mtr)

1.58

-

-

... More
RRHG Cement Masonary (1:5) With cement ( 0.86 Cum / Mtr)

63.64

-

-

... More
Design & providing Galvanised Chain Linking Fencing with 2 Mtr Height around TRF specification.

80

-

-

... More
N.B: The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.