Odisha Industrial Infrastructure Development Corporation Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Industrial Infrastructure Development Corporation - IDCO Tender

Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Apr 2023
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, fabrication & erection of 100 x 50 x 6 mm G I Channel as required for straight cross arm complete as per technical specification and direction of E.I.C.

125.12

-

-

... More
Supply & erection of GI 11kV V-Cross arm along with G.I. Back Clamp ) as per technical specification and direction of E.I.C.

5

-

-

... More
..........do.................of GI F-Clamp

5

-

-

... More
..........do................ of G.I Nut, Bolt & Washers

5

-

-

... More
SITC of HT(11 KV) stay sets for overhead line including excavation & mass concreting of stay pit , stay binding etc. complete with HT stay insulator, stay clamp & bow, stay plate ,stay rod, 7/10 SWG G.I stay wire, thimble etc. complete as per technical specification and direction of E.I.C.

4

-

-

... More
SITC of 11 kV Polymer Type Pin Insulator complete as per the site requirements.

21

-

-

... More
SITC of 11kV (T & C type) Polymer Type Disc insulator (45kN) .

12

-

-

... More
SITC of 11KV (T & C type) Hardware fitting (45kN).

12

-

-

... More
Supply & Stringing of 100 sq mm AAAC complete.

0.63

-

-

... More
Supply and Installation of Danger Board

7

-

-

... More
Sundries (Painting, Al.Binding Tape & Wire, Anticlimbing device,clamp connector,jumpering materials,socket & other cable accessories,insulating tape etc)

1

-

-

... More
Upgradation of 11/0.4kV 63kVA Transformer to 11/0.4 KV,500 KVA, Plinth mounted Substation(With boundary wall)

-

-

-

... More
Supply, fabrication & erection of GI members like a)100 x 50 x 6 mm Pressure Channel (9.2Kg/m), b) ABS mounting channel 100 x 50 x 6 mm (9.2Kg/m),c) HGF Mounting channel 75 x 40x 6 mm Channel(6.8Kg/m) , d) 50 x 50 x6 mm Angle for cantilever arrangement (4.5 Kg/m) & e) DP Bracing channels of size 100x50x6mm, 50x50x6mm-equal angle f) LTDB mounting Angle 50 x 50 x6 mm as required for the Double Pole Structure(for mounting LTDB,ABS & HGF- on cantilever ) complete as per technical specification and direction of E.I.C.

264.74

-

-

... More
Supply & fixing of G.I. Nut, Bolt & Washers as required & complete as per technical specification and direction of E.I.C.

25

-

-

... More
SITC of 11KV (T & C type) Disc insulator 45kN Polymer.

3

-

-

... More
SITC of 11kV (T & C type) Hardware fitting 45kN.

3

-

-

... More
SITC of 11kV AB switch 3 Pole (400 Amp) with operating handle, “I” hook etc as per the site requirement & complete as per technical specification and direction of E.I.C.

1

-

-

... More
SITC of 11kV H. G Fuse 3 Pole(400A) as per the site requirement & complete as per technical specification and direction of E.I.C.

1

-

-

... More
SITC of 9 KV (10 kA) Lightning Arresters complete as per technical specification and direction of E.I.C.

3

-

-

... More
SITC of pipe earth electrode made out of 40 mm dia class-B G.I Pipe of 3 mtr. Long with arrangements for fitting and termination of G.I Flat/G.I wire with G.I nut-bolts and washers including cost of excavation of pole pit in all kind of soil, burnt wood charcoal salt, bricks masonry chamber with removable RCC cover complete as per technical specification and direction of E.I.C.

2

-

-

... More
Supply and fixing of 50 x 6 GI flat for N earthing & 25 x 5 G.I flat as required for earthing of different parts complete as per technical specification and direction of E.I.C.

25

-

-

... More
SITC of 500 kVA 11/0.4 kV out door type (BIS & BEE Level-2 rated) Copper wound Transformer with tap changer complete as per technical specification and direction of E.I.C.

1

-

-

... More
Supply, laying (in UG trench with brick protection as required & with provision of cable ladder)& termination with lugs & testing and commissioning of 1 core x 300 sq mm Al Armoured PVC Cable complete as per technical specification and direction of E.I.C.

48

-

-

... More
Supply of all reqd. materials & installation of Transformer Plinth of height 2.1m (as per prior approved drawing from EIC/TPSODL) and complete with curing as per technical specification and direction of E.I.C.

1

-

-

... More
SITC of LT Distribution Box with MCCB, Aluminium Busbar for 2 bay including kitkat fuse complete as per technical specification and direction of E.I.C.. (as per prior approved drawing from EIC/TPSODL)

1

-

-

... More
Sundries (survey,tree cutting,danger plate,piercig connector,small size nut & bolt,Binding Wire, Insulating Tape,socket and cable accessories etc)

1

-

-

... More
Supply of all reqd. materials & construction of boundary wall with MS gate complete as per TPSODL technical provision/ specification and direction of E.I.C. (as per prior approved drawing from EIC/TPSODL)

1

-

-

... More
Supply & filling of sand & Supply and laying of gravel complete as per technical specification and direction of E.I.C.

1

-

-

... More
Construction of 3ph 5W LT Line with 3x95+1x70+1x16sq.mm with LT XLPE AB Cable on existing poles- 0.4Km (12 spans_ (2 circuit)

-

-

-

... More
Supply, Stringing, testing and commissioning of 3x95+1x70+1x16sq.mm AB Cable complete.

0.84

-

-

... More
....do... of Dead End Clamp

8

-

-

... More
....do... of I hook for AB Cable.

8

-

-

... More
....do... of Pole Clamp for I Hook complete.

26

-

-

... More
....do... of Suspension Clamp with I Hook for AB Cable.

18

-

-

... More
....do... of G.I Nut, Bolt & Washers as required.

5

-

-

... More
Sundries (survey,tree cutting,danger plate,piercig connector,small size nut & bolt,Binding Wire, Insulating Tape,socket and cable accessories etc)

1

-

-

... More
Dismantling

-

-

-

... More
Dismantling of materials/equipment of the existing installation and handing over to the concerned TPSODL section officer with prper documentation complete as required.

1

-

-

... More
N.B: The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.