Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
Refer DocumentsDocument Cost
₹ 7,080Tender Fee
Refer Documents
Summary
Laying Of Treated Ater Rising Mainfrom Meil Pumping Main Emc Parkpump House To Bagchi Sri Sankar Cancer Centre And Research Institute And Bagchi Karunashraya Palliative Care Centre In Bhubaneswar In The District Of Khordha
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_IDCO_71554_1Bid Award Id
ViewTender No
PC/EST/E-20/2021-22Tender Authority
Odisha Industrial Infrastructure Development Corporation ViewPurchaser Address
-Website
http://tendersodisha.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation of pipe line trenches in laterite rock or any hard rock (other than granite or disintegrated rock)removed by chiselling including dressing & levelling & benching the bed not exceeding 1.50m depth & depositing the soil within initial lead of 50m & as per specification approved by the department.
-
-
-
Upto 1.50m initial lift
326
-
1338
Filling the pipe line trenches with sand including watering & ramming etc. complete including all labour, T&P, cost of sand, conveyance, , royalty, loading & unloading as per specification & direction of EIC.
184.15
-
474.9
Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC.
755.8
-
110.94
Providing all materials, labour, T&P for laying of centrifugally cast (Spun) Ductile Iron pressure pipes for water works purpose with socket & spigot ends confirming to IS-8329/2000 with 3rd revision in standard lengths for classification K-9 suitable for push on joints (Rubber Gasket 'D' jointing) with outside zinc coating as per IS-8329/2000 including aligning the pipes inside trench as per IS-12288/1987 including testing the pipe line with required water pressure as per IS-8329/2000 amendment 1st, Sep. 2011 etc.all complete as per specification & direction of EIC (Excluding cost for earth work, jointing of specials, rubber gasket & fittings which shall be paid separately).
-
-
-
200mm dia (NB) S/S pipe K-9 suitable for push-on joint
800
-
2340
Providing all labour, T&P and making push-on joint with rubber gasket ring as per IS-5382/1985 1st Revision suitable for D.I pipe and fittings of the following nominal dia including testing of the joints with required water pressure (The cost is inclusive of cost of ring) and all complete as per specification & direction of E.I.C.
-
-
-
Rubber Gasket (EPDM/SBR) suitable for 200mm dia D.I pipes & fittings with ISI mark.
15
-
399.2
Labour Only
145
-
211.1
Providing all materials, labour, T&P and laying in trenches following D.I fittings & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. confirming to IS-9523:2000, 1st revision with pressure rating PN-1 of following nominal diameter, all complete including test the joints with required water pressure as per specification & direction of EIC. (Excluding cost of earth work in trenches, back filling & rubber gasket)
-
-
-
300 x 300 x200mm A/S Tee
1
-
7307
300mm Flanged Socket
1
-
5750
300mm Flanged Spigot
2
-
4432
300mm MJ Collar
1
-
6588
200mm Flanged Spigot
7
-
2396
200mm MJ Collar
1
-
5869
200mm Flanged Socket
1
-
3114
200 x 200 x200mm A/S Tee
1
-
4791
200mm dia Blank Flange
1
-
1318
Providing, fitting & fixing of following size valves as per IS specifications including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure & all complete as per specification & direction of E.I.C.
-
-
-
300mm dia D.I Sluice valve (Non rising spindle) of PN-1.0 as per IS-14846/2000 with ISI mark.
1
-
31452
200mm dia D.I Sluice valve (Non rising spindle) of PN-1.0 as per IS-14846/2000 with ISI mark. (For washout)
2
-
16803
80mm dia D.I. Tamper Proof Kinetic air valve without Isolating SLB of PN-1.0 as per IS-14845/2000 with ISI mark.
1
-
18238
Providing all materials, labour and T&P required for construction of RCC M-25 valve chamber of following minimum size having minimum cube strength 250Kg/cm²at 28 days confirming to IS-456/2000 and IS-3370 at all locations & heights using graded H.G. stone aggregate (crusher broken ) of 20mm & down size including machine mixing, lifting, conveying, placing in position, mechanical consolidation, curing, dewatering, if necessary, including cost for rigid, levelled & plumbed centring & shuttering to required slope, alignment & size for all kinds of RCC work with steel centring materials with all bracing, ties, anchorage & supports & removing the same after required interval from the date of casting, the minimum thickness of RCC base slab, all side walls and roof slab shall be not less than 200mm, 150mm and 125mm respectively,Providing & Placing MS reinforcement (HYSD bars) of required dia including cutting, bending, binding, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires 18 to 20 gauge soft drawn & cold annealed. PCC 1:3:6 with 40mm size h.g. stone metal (crusher broken) of 100mm thick, earth work excavation in all kinds of soil/rock including back filling duly watered & rammed as per approved design & drawing and fixing pre-cast factory made RCC man hole cover with frame of clear opening of 600mmx450mm and providing and fixing of Polypropylene Steel Reinforced Man Hole steps of approved quality and size in two parallel lines of 300mm spacing in vertical walls with centre to centre 375mm(staggered).Painting the chamber with 2 (two) or more coats of approved water proofing cement paint over a coat of cement wash. Printing and writing the wall sign board of approved size and specification including cost of all materials, labour, T&P, royalties, all and hire & running charges of machineries with POL etc. all complete as per specification & direction of EIC.
-
-
-
Inner size 1000mm x 1000mm x 1200mm height valve chambers
5
-
24117
Construction of RCC M-20 thrust block of following minimum size having minimum cube strength 200Kg/cm²at 28 days confirming to IS-456/2000 and IS-3370 at all locations & heights using graded H.G. stone aggregate (crusher broken ) of 20mm & down size including machine mixing, lifting, conveying, placing in position, mechanical consolidation, curing, dewatering, if necessary, including cost for rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel centering materials with all bracing, ties, anchorage & supports & removing the same after required interval from the date of casting, Providing & Placing MS reinforcement (HYSD bars) of required dia including cutting, bending, binding, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires 18 to 20 gauge soft drawn & cold annealed, PCC 1:3:6 with 40mm size h.g. stone metal (crusher broken) of 100mm thick earth work excavation in all kinds of soil/rock including back filling duly watered & rammed as per approved design & drawing etc. all complete as per specification & direction of EIC.
-
-
-
RCC Thrust block of size 1000mm x 1000mm x 1000mm height
1
-
10742
Providing all materials , labour, T&P for making flange joints with the pipes & fittings including supply of required & approved size of M.S. nuts & bolts, washer & rubber insertion & paints etc. including testing the joints with required water pressure etc. all complete as per specification & direction of EIC.
-
-
-
300mm dia Flange Joint
2
-
829.4
200mm dia Flange Joint
5
-
534.9
Supply,Installation,testing & commissioning of Smart water meter suitable for following pipe lines with IOT Technology using LORA or NBIOT technology & related Infrastructure work.
-
-
-
200mm dia Water meter
1
-
110000
GST as applicable Will be Paid Extra.
-
-
-