Odisha Industrial Infrastructure Development Corporation Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 2,91,884Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IDCO_103648_1Bid Award Id
ViewTender No
PC/EST/E-05/2024-25Tender Authority
Odisha Industrial Infrastructure Development Corporation ViewPurchaser Address
-Website
http://tendersodisha.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
3 core x 120 sqmm AL A2XFY
400
-
-
... More
3 core x 240 sqmm AL A2XFY
200
-
-
... More
Supply, delivery, laying & testing of following sizes XLPE insulated 650/1100 Volts grade XLPE Insulated Control Cables laying in existing Tray/ Wall/ Trench/RCC hume pipe / HDPE pipe which is required with copper conductors & end termination as per IS 7098/Part-I/1988with making good the damages caused as required and as per direction of Engineer-in-charge.(As per TPNODL Specification & shall be approved from EIC of IDCO ), Make:- KEI/POLYCAB/HAVELLS/RR KABLE
-
-
-
... More
10C X 2.5 Sq mm
500
-
-
... More
4C X 2.5 Sq mm
400
-
-
... More
Supply, delivery, installation, testing & commissioning of HV Cable(33KV) End Termination Kit (Indoor & Outdoor Type )
-
-
-
... More
Indoor Type:
-
-
-
... More
3 core x 95 sqmm AL A2XFY (Indoor Type )
2
-
-
... More
3 core x 120 sqmm AL A2XFY (Indoor Type )
4
-
-
... More
3core x 240 sqmm AL A2XFY (Indoor Type )
4
-
-
... More
Outdoor Type:
-
-
-
... More
3 core x 95 sqmm AL A2XFY (Out door Type )
2
-
-
... More
3 core x 120 sqmm AL A2XFY (Out door Type )
4
-
-
... More
3core x 240 sqmm AL A2XFY (Out door Type )
4
-
-
... More
EARTHING
-
-
-
... More
Supply of materials and installation of pipe earth electrode made out of 40mm dia class B G.I. pipe of 4.5 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
10
-
-
... More
Earthing with copper plate 600m x 600mm x 3mm thick including accessories , and providing masonry enclousre with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal/coke & salt as required.
6
-
-
... More
Supply of material & laying under ground / floor / wall including termination and testing of following sizes of copper earthing conductor for loop earthing of equipments, switch boards & panels as required complete as per direction of Engineer-in-charge.
-
-
-
... More
25 x 5 mm copper flat
180
-
-
... More
50 x 6 mm copper flat
300
-
-
... More
33KV PANEL BOARD
-
-
-
... More
Design ,Supply, installation, testing and commissioning of Extendable type 33kV VCB Indoor HT switchgear TTA panel module consisting of 1no.- Incomer feeder (from 33KV OH Line ) and (4nos.- Outgoing feeders, 1 nos.-Bus PT Panel) including all accessories conform to the relevant IS/IES 61439 standard and all breakers shall be with A/V/KWH/MFM meters and the necessary power pack, internal lighting, thermostats, with made out of 3 mm thick CRCA sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade dust, damp & vermin proof, having door and compartmental arrangement for each compartment,shall be provided all incomers & outgoing cables shall be a top entry in the panel. Also having separate Arc flash Exhaust top compartment system & with motorized isolator, 1600A 33KV Al Bus bar, Numerical Relay (50/51,50N/51N, 27/59) and other Relays as required, Scope includes manufacturing, transportation, loading, unloading, shifting to the final location, and interconnection between accessories mounted on HT VCB with the mounting of loose accessories supplied by the vendor. As per special conditions of the contract making good the damages caused complete as per the direction of the Engineer-in-charge. (Make:- OEA of ABB/Schneidner/Siemens)
-
-
-
... More
INCOMER PANEL -1 No
-
-
-
... More
33 KV Indoor Electromechanically Draw out type VCB-1250A,26.3KA 3 Sec, 50 HZ, Busbar 1600A(Aluminum) & (CT 600-300/1-1A), PT 33/√3 kV / 110/√3-110/√3V)for Transformer Protection Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel.with all required tripping,closing by 48V DC circuit & 110V AC indication circuit.
-
-
-
... More
1 no- Digital Multi functional Meter
-
-
-
... More
1 no- Power Pack for Electrical Closing Mechanism
-
-
-
... More
1 no- Digital Volt Meter & Ammeter with s/s
-
-
-
... More
1 no- Emergency Trip Push Button.
-
-
-
... More
1 Set - Trip Circuit Healty Test Push Button with Indicating Lamp
-
-
-
... More
1 no - Trip/ Neutral/ Close switch
-
-
-
... More
One-(1)- Master Trip Relay with Electrical Reset Facility Push button
-
-
-
... More
One (1)- 33KV surge diverter with breaker arrangement
-
-
-
... More
OUTGOING FEEDERS-4 Nos
-
-
-
... More
33 KV Indoor Electromechanically Draw out type VCB-800A, 26.3KA 3 Sec, 50 HZ , (CT 400-200/1-1A) for 2.5 MVA Power Transfromer 33/6.6 KV & CT (100-50/1-1A) for 100kVA, 33/.433 kV Station Transfromer for Transformer Protection Relays to be installed on the panel, Multi-function Meter to be installed above the panel, Energy meter to be installed on the panel with all required tripping, closing by 48V DC circuit & 110V AC indication circuit.
-
-
-
... More
1 no- Emergency Trip Push Button
-
-
-
... More
1 no- Digital Multi functional Meter, Digital Volt Meter & Ammeter with s/s
-
-
-
... More
1 no- Power Pack for Electrical Closing Mechanism
-
-
-
... More
1 Set - Phase indicating lamps (R,Y,B), ON/OFF, Trip and Spring Charged.
-
-
-
... More
1 no- Emergency Trip Push Button.
-
-
-
... More
1 Set - Trip Circuit Healty Test Push Button with Indicating Lamp
-
-
-
... More
1 no - Trip/ Neutral/ Close switch
-
-
-
... More
One-(1)- Master Trip Relay with Electrical Reset Facility Push button
-
-
-
... More
Panel as above
-
-
-
... More
BUS PT -1 Nos.: 33KV BUS BAR PT having ratio 33KV/1.732/110V/1.732/110V/1.732 to be wired for all compartment breakers provided with suitable HT Fuse .
-
-
-
... More
1 no. of trolley for VCB pull in/pull out operation
-
-
-
... More
Complete duly factory wired as per approved SLD
-
-
-
... More
NB: The Protection & Metering CT Ratio, burden & Accuracy will be finalized on GA GTP as per the direction of EIC.
-
-
-
... More
Panel as above
1
-
-
... More
Design,Supply, delivery, installation, testing & commissioning of indoor ACDB Panel wall mounted type distribution boards with Suitable AL Bus Bar ,Indication Lamp, Selector Switch, digital Voltmeter & Ammeter with S/s , made out of 2mm thick CRCA sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged door and compartmental arrangement for each equipment, cable alley chamber in each outgoings & busbar chamber on the top of the panel running horizontally, having provision for cable/ conduit Top/Bottom entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
-
-
-
... More
Incomer:
-
-
-
... More
1no-63A,10KA, 4Pole ,MCB 'C'
-
-
-
... More
100A AL BUS BAR
-
-
-
... More
One(1) set of – 63/5A , 15VA, CL 1.0. CTs
-
-
-
... More
Out Going :
-
-
-
... More
2no-32A, 10 KA, DP, MCB(Space heater for all comparatment & Spare )
-
-
-
... More
2no-16A, 10KA, DP, MCB( Lighting & Spring Charge of breaker inside panel)
-
-
-
... More
2no-10A, 10KA, SP, MCB(Battery Charger panel & Spare )
-
-
-
... More
Panel as above
1
-
-
... More
Design, Supply, delivery, installation, testing & commissioning of indoor DCDB Panel wall mounted type distribution boards with Suitable AL Bus Bar, Indication Lamp, Selector Switch , Digital Voltmeter& Ammeter with S/s , made out of 2mm thick CRCA sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged door and compartmental arrangement for each equipment,Indication lamp,Ammeter,voltmeter cable alley chamber in each outgoings & busbar chamber on the top of the panel running horizontally, having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
-
-
-
... More
Incomer :
-
-
-
... More
1no-63A , 10KA , DP ,MCB 'C'
-
-
-
... More
63A Cu BUS BAR
-
-
-
... More
One(1) set of – 63/5A , 15VA, CL 1.0. CTs
-
-
-
... More
Outgoing:
-
-
-
... More
8no:16A, 10KA, DP MCB "C"
-
-
-
... More
Panel as above
1
-
-
... More
Design Supply, delivery, installation, testing & commissioning of Outdoor feeder Piller Panel foundation mounted type distribution boards with Suitable AL Bus Bar ,Indication Lamp, Selector Switch, Digital Voltmeter & Ammeter with S/s, made out of 3mm thick CRCA sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof with proper IP rating & having hinged double door arrangement, slope top enclosures and control panels provide protection from dust, dirt, oil and strong jets of water with suitable CT cable alley chamber in each incomer, outgoings & busbar chamber on the top of the panel running horizontally, having provision for cable/ conduit top/bottom entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
-
-
-
... More
Incomer :
-
-
-
... More
1no-200 ,4P ,MCCB 36KA
-
-
-
... More
400A AL BUS BAR
-
-
-
... More
One(1) set of – 200/5A , 15VA, CL 1.0. CTs
-
-
-
... More
Outgoing:
-
-
-
... More
2no:160A 4P MCCB 36 KA
-
-
-
... More
Panel as above
1
-
-
... More
Design ,Supply, delivery, installation, testing & commissioning of indoor Automaic float cum boost Battery charging panel I/P 415V ,O/P 48V DC rated 25A ,with battery 4 nos of 100AH VRLA type, Panel to the relevant IS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
1
-
-
... More
Distributuion Transfromer
-
-
-
... More
Design ,Supply ,Erection , Testing & commissioning etc of 100 KVA, 33/0.433 KV, 3 Phase, 50 Hz, core type, natural oil cooled, Copper Wound, outdoor type distribution transformer manufactured as per IS: 1180(Part-1): 2014, Level-II with complete fittings,all accessories cable supporting riser arrangement with and all required accesories for first filling of oil and LT side cable end box as per latest specification. as required and as per direction of Engineer-in-charge(As per TPNODL Specification & shall be approved from EIC of IDCO ) (Make :-OTPL/ALFA/OEU/ABB)
1
-
-
... More
Power Transfromer
-
-
-
... More
Design ,Supply ,Erection , Testing & commissioning of 2.5 MVA, 33/6.6 KV, 3 Phase, 50 Hz, core type, , natural oil cooled, Copper Wound, outdoor type distribution transformer manufactured as per IS: 1180(Part-1): 2014, Level-II/Star-I with complete fittings, all accessories, first filling of oil having Off Load Tap Changer ranging from +5% to – 10% @ 2.5% each and LT side cable end box as per latest specification with cable supporting arrangement, With transformer Oil drainage , drainage piping and carried out into a special oil sump provisioning as per BIS, communication relay and control wire shall be integrated in such a way with Transformers to show WTI OTI Bucholtz fault status in the 33 KV HT Panel.(As per TPNODL Specification & shall be approved from EIC of IDCO) (Make :-OTPL/ALFA/OEU/ABB)
2
-
-
... More
Providing all materials, labour, T&P required for construction of RCC M20 Grade RCC Transfromer Plinth (3.8 mtr x 3.5 mtr x 1 mtr Above G.L for 2.5 MVA Transformer) and (0.9 mtr x 0.9 mtr x1 mtr Above G.L for 100kVA Transformer) having foundation cube strength 200 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using stone aggregate (Crusher broken) of 20 mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC Raft foundation base 300mm, vertical wall shall be not less than 300mm , top slab at plinth level thickness 200 mm minimum respectively. PCC 1:4:8 with 40 mm size agreegate, 100 mm thick PCC in below Raft and 150mm thick in plinth flooring , earth work excavation in all types of soil , filling the foundation with excavated earth and sandfilling upto plint level laying in layers not exceeding 23 cm thick well watered & rammed etc. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all supports including providing supplying, laying, placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design, drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed) all complete as per direction of Engineer-in-charge.
3
-
-
... More
Construction, Providing, Supplying and fixing of G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers & Made of G.I. wire of dia 4 mm fixing in MS Angle of 60x60x5 mm fencing poles having height of 2.50 Mtr fixed in cast-in-situ PCC M-20 concrete in foundation footing of size 600 mm x 600 mm size with 300mm depth from top and base of plain cement conrete of proportion with C.C. (1:4:8) of size 600mmx600mm size 100 mm depth including excavating foundation pit for each pole including watering & curing for required days. All complete as a set including MS angle of given size MS gate (with proper size) , GI fencing , including excavation,PCC, CC filling, Shuttering including curing cost and conveyance of all materials, royalties , taxes all labour , labour cess, T & P required for the work etc. complete including dewatering if required as per the direction of the Engineer-in-charge.
40
-
-
... More
HDPE PIPE
-
-
-
... More
Supply, laying or fixing of 200 mm HDPE pipe for Vertically laying of 33KV cable form Over head tapping from 33KV HT panel incomer with suitable clamp & arrangement as required.
200
-
-
... More
LIGHTNING PROTECTION SYSTEM
-
-
-
... More
Supplying and fixing of lightning conductor finial, made of 25 mm dia 1000 mm long G.I. tube & stay arrangement, having single prong at top, with minimum 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required and as per the direction of Engineer in charge. Make: Dehn, ABB, Erico
4
-
-
... More
25 X6 mm GI strip with all supports as required
150
-
-
... More
50 X6 mm GI strip with all support as required
100
-
-
... More
Supply & fixing of Safety Equipments
-
-
-
... More
33KV Rubber Mat(1M x 2M x 3MM)
6
-
-
... More
Shock Treatment Chart
3
-
-
... More
33KV Safety Gloves
2
-
-
... More
Sub Station Building
-
-
-
... More
Design, construction, testing & commissioning of M30 Grade RCC frame structure 33KV HT panel room of clear height 5 mtr with RCC roof, parapet, the plinth height shall be 600 mm minimum above the near road, plinth protection including all finishing work like excavation, shuttering , sand filling, Kota flooring, Bricks wall , Indoor outdoor Plastering, primer with distemper painting, entrance gate with MS rolling shutter, MS Window with grill with toughen door sliding , suitable indoor cable trench with chequered plate & MS angles arrangements as per BIS, chajja on Door & Window, roof rain water drainage arrangement, terrace waterproofing treatement with 25mm thick grading concrete as per IS standard & internal electrical installation with fitting & fixtures as required etc all complete as per approved design, drawings, specification & direction of EIC.
87
-
-
... More
Cable Trench
-
-
-
... More
Providing all materials, labour, T&P required for construction of RCC M-20 Grade Cable trench of intenal size (1.20 Mtr width & 1.20 Mtr depth ) having cube strength 200 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using h.g. stone aggregate (Crusher broken) of 20mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, vertical wall & precast cover slab shall be not less than 150mm, 150mm & 150mm (avg.) respectively. PCC 1:4:8 with 40mm size h.g.c.b. metal of 100mm thick ,earth work excavation in all types of soil , filling the foundation with excavated earth, laying in layers not exceeding 23cm thick well watered & rammed, providing,fitting & fixing of 150mm thick pre-cast cover slab for opening of trench etc. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all supports and removing the same & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed).the above rate including excavation,sandfilling,RCC , reinforcement work and supplying and fixing of MS angle of size 50x50x6mm double rack in the trench. all complete as per drawing & direction of Engineer in charge.
100
-
-
... More
33KV motorized Isolator(Out door )
-
-
-
... More
Design ,Supply, installation, testing and commissioning OUTDOOR TYPE Motorized isolator off load 33KV,50 HZ ,Rated voltage nominal / maximum-33/36, Rated current -1250A,Operating Mechanisim -Motor (415V, 3 phase, AC, 50Hz/220V, 1 phase, AC, 50Hz) with other accessories as required and follow the technical specifications with all complete as per the direction of Engineer-in-charge.
4
-
-
... More
6.6 KV Isolational panel
-
-
-
... More
Design,Supply, Installation, testing and commissioning OUTDOOR TYPE 6.6kV, 1250A, 26.3KA/3 SEC, ISOLATION ICOG PANEL with other required protections, made out of 3 mm thick CRCA sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged double door and compartmental arrangement as per BIS, slope top on these enclosures and control panels. This control panel shall be weather proof applications and use in corrosive environments, earthing studs as per specification mentioned below duly factory wired conforming to the relevant BIS and appropiate RCC foundation required as per the direction of Engineer-in-charge.
2
-
-
... More
NGR Panel
-
-
-
... More
Design,Supply, Installation, testing and commissioning of indoor 6.6 KV Neutral grounding Resistor (NGR ) with Fail safe Monitoring Relay and other accessories , tolerance more than +/- 10%. made out of 2mm thick CRCA sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged door and compartmental arrangement for each equipment,Indication lamp,Ammeter,voltmeter cable alley chamber in each outgoings & busbar chamber on the top of the panel running horizontally, having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
2
-
-
... More
Fire Extinguisher
-
-
-
... More
S/F of ABC 6 Kgs Stored Pressure Type Fire Extinguisher
2
-
-
... More
S/F of CO2 4.5 Kgs Hand Wheel Type Fire Extinguisher
3
-
-
... More
S/F of 9 Ltrs Stored Pressure Type Fire Extinguisher
1
-
-
... More
Internal Wiring
-
-
-
... More
Wiring to light, ceiling fan, exhaust fan, call bell & 6A On board with 1.5sqmm FRLS PVC insulated 1100 volt grade multistranded copper conductor wire for phase, neutral and earth continuity conductor run inside 2mm wall thick ISI mark FRLS rigid PVC conduit pipe surface or recessed in wall/ column/ ceiling / above false ceiling / under the floor of the building including supply of materials such as clip-in type modular switches, metallic concealed box, wire, , junction box etc as per the electrical layout drawing & technical specifications complete with making good to the damages caused as required and as per direction of Engineer-in-charge.
-
-
-
... More
Single light point controlled by one 6A switch
12
-
-
... More
Ceiling Fan Point
3
-
-
... More
6A Socket & switch on existing Switch board
2
-
-
... More
Supply, delivery, installation & testing of suitable size Separate metallic concealed box with modular plate and cover in front on surface including following type plug boards with interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge.
-
-
-
... More
2x6 ampere plug boards consisting of a 2nos 6 amp clip-in type modular shuttered plug socket and 2nos 6 A clip-in type modular switches fixed on metallic concealed box connections etc.
2
-
-
... More
6 / 16 ampere plug boards consisting of a 6/16 amp clip-in type modular shuttered plug socket fixed on metallic concealed box
4
-
-
... More
Supply, delivery, installation & testing of AC boards consisting of 25A Modular switch with 16A Moular socket in indivisual Modular G.I Box making good the damages caused complete as required and as per direction of Engineer-in-charge.
2
-
-
... More
Supplying and fixing 3 pin, 6 amp ceiling rose including connections etc. as required, as per drawing and as per the direction of Engineer in charge
4
-
-
... More
Wiring for circuits & submain with following number & sizes of FRLS PVC insulated 1100 volt grade multistranded copper conductor wire run inside 2mm thick PVC conduit pipe recessed in ceiling/ column/ walls of building including supply of all materials such as wires, PVC conduit, junction box & pull box etc complete with making good the damages caused as required and as per direction of Engineer-in-charge.
-
-
-
... More
2 numbers single core 1.5 sqmm copper wire for phase & neutral and 1 number single core 1.5 sqmm copper wire for earth continuity conductor.( for point wiring beyond 5mtrs long & 6A Switch Socket (Sep. board ) & 2nos 6A Switch Socket (Sep. board )
90
-
-
... More
2 numbers single core 2.5 sqmm copper wire for phase & neutral and 1 number single core 2.5 sqmm copper wire for earth continuity conductor.
70
-
-
... More
2 numbers single core 4.0 sqmm copper wire for phase & neutral and 1 number single core 4.0 sqmm copper wire for earth continuity conductor.
90
-
-
... More
2 numbers single core 6.0 sqmm copper wire for phase & neutral and 1 number single core 6.0 sqmm copper wire for earth continuity conductor.
50
-
-
... More
Supplying and fixing suitable size metallic concealed box with modular plate and cover in front on surface or in recess, including providng and fixing 1 no. Stepped type Modular Fan regulator (2 module), connections etc. as required. as per drawing and as per the direction of Engineer in charge
2
-
-
... More
Installation of Fittings & Fixtures
-
-
-
... More
Installation ,Testing, Commissioning of suface/wall fittings of all sizes and shapes containing upto two LED lamps per fitting, complete with all accessories including connections etc. as required as per drawing and as per the direction of Engineer in charge
-
-
-
... More
20 Watt LED Tube Light
8
-
-
... More
10 Watt LED Bluk Head
4
-
-
... More
Supply, installation, testing and commissioning of ceiling fan & exhaust Fanincluding wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, . as required, as per drawing and as per the direction of Engineer in charge
-
-
-
... More
1200 mm sweep
3
-
-
... More
Supply, installation, testing and commissioning of Split AC ,BEE 5 star rated as with all fitting as dranage pipe ,Outdoor bracket,and all other accessories per drawing and as per the direction of Engineer in charge
-
-
-
... More
1.5 Ton
2
-
-
... More
Supply, delivery, installation, testing & commissioning of L.T. indoor wall mounted double door type distribution boards of original factory made enclosures of the same brand as the MCB conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
-
-
-
... More
BDB (6way(8+18) TPN DB) (IP-43 IK 09 with Metalic Door)
1
-
-
... More
Supply, delivery, installation, testing & commissioning following rating, four pole, (three phase and neutral), 415 volts, Residual current operated Circuit Breaker with Overcurrent protection" (RCBOs), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of Engineer-in-charge
-
-
-
... More
32A
2
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
6 amps to 32 SP MCB 10KA 'C'
13
-
-
... More
Supply & Fixing of Cable trays manufactured from steel wires, welded together and bent into final shape.. All Accessories including couplers (CE25/CE30 screw-based system combination) mounting accessories (Mechanically tested & supplied by cable tray manufacturer must be used) are required of same finish as per site requirement.Electro zinc plated after manufacture in accordance with the EN standard 12 329: at least 120 h of SST. All trays shall be arranged and positioned on the site itself in accordance with the manufacturer's instructions.The deflection of the wire cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Assemblies with specific fire-resistant properties must have an E30-E90 certificate issued by an approved laboratory in accordance with the tests described in the standard DIN 4102-12. The wire cable tray short-circuit resistance must be tested by an independent laboratory. For the purpose of assembling the various wire cable tray, only fast coupling systems or screw-based (CE25/CE30) systems must be used. These must be designed, mechanically tested and supplied by the wire cable tray manufacturer.The electrical resistance of the joints must not exceed 50 mΩ and must be tested in accordance with the procedure described in the standard IEC 61537.
-
-
-
... More
300 X 50 X 1.6mm
200
-
-
... More
300 X 50 X 1.6 mm Bend
6
-
-
... More
P/L following dia. R.C.C. hume pipes, NP2 class, excvation, back feeling, sand feeling spigot jointing, filletting in 1:1 C.M., including plugging & curing etc. complete as directed by EIC.
-
-
-
... More
300mm NP2 class
40
-
-
... More
Supplying and fixing of following sizes of Highly Mechanical Strength class 2mm PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
25mm
150
-
-
... More
20mm
200
-
-
... More
Constructing masonry Manhole Chamber 100x100x120 cm inside, With 250mm thick Fly ass brick wall of class designation 7.5 in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) with 100 mm thick RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , necessary excavation, back filling, foundation concrete 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design as per direction of EIC.
6
-
-
... More
Supplying, filling, spreading & leveling stone boulders of size range 40mm and above,in the required thickness, for all leads & lifts with PCC approach road easily access to all electrical components inside proposed Substation with all complete as per direction of Engineer-in-charge.
23
-
-
Evaluation Notes How It Works ?