Odisha Industrial Infrastructure Development Corporation Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Industrial Infrastructure Development Corporation - IDCO Tender

Pipes and Pipe Related Activities
Eprocure
Opening Date21 Aug 2021
Closing Date9 Sep 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Compound Wall

306.86

-

186.4

... More
Supplying & Filling in foundation trenches and plinth, ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift, including cost, conveyance, loading, unloading, stacking,royalties of all materials, cost of all labour, sundries, T&P required for the work etc. complete excluding GST in all respect as directed by the Engineer- in -charge. (Measurement will be taken on finished compacted section only)

-

-

-

... More
Building

376.72

-

329.5

... More
Compound Wall

30.69

-

329.5

... More
Providing and laying Plain Cement Concrete of proportion (1:3:6) in foundation and floors (i.e. below the base course of the flooring) using cement , 40 mm size crusher broken H.G Stone Metal and screened & washed sharp river sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layer including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pump required for the work etc complete excluding GST in all respect as directed by the Engineer-in-charge. .

-

-

-

... More
Building

70.42

-

4270.5

... More
Compound Wall

34.34

-

4270.5

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth including cost, conveyance , loading,unloading,royalties of all materials, cost of all labour, Sundries, T&P required for the work complete in all respect excluding GST as directed by the Engineer-in-charge. .

115.2

-

410

... More
Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as  preconstructional anti- termite  treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation,  top surface of  plinth   filling, junction of walls and floors along with external  perimeter of the  building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. complete in all respect as per specification as directed by the Engineer -in -charge.

-

-

-

... More
a) Treatment to soil below raft: Before laying the rubble soling and pcc the compacted and leveled soil shall be treated at 5 litre / sq.m.

-

-

-

... More
b)Treatment to soil along the retaining wall:The soil coming in contact with the retaining wall shall be treated at 5 litre per sq. m. The treatment shall follow the backfilling as backfilling is done in stages of 30 cms but not to exceed a depth of 1metre. Rodding may be carried out to facilitate the treatment.

-

-

-

... More
c)Treatment to soil along the external perimeter of the building:The soil around the external perimeter of the building up to a depth of 30 cm shall be treated at 2.25 litres per linear metre. Rodding may be carried out to facilitate this treatment.

-

-

-

... More
d) Treatment of soil surrounding pipes, wastes and conduits:When pipes, wastes and conduits enter the soil inside the area of the foundation, the soil surrounding the point of entry must be loosened around each such pipe, waste or conduit for a distance of 15 cm and upto a depth of 7.5cm and loosened soil shall be treated with chemical emulsion.

-

-

-

... More
e)Spraying equipment:A pressure pump shall be used to carry out spraying operations to facilitate proper distribution of chemical in the soil.

-

-

-

... More
Note: All the Anti-termite treatment shall be executed through a recognised agency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of 10( Ten ) years from the certified date of completion for the satisfactory performance of the entire Anti-termite treatment system. The Defect Liability Period of the Anti-termite treatment is Ten years.The contractor has to furnish bank guarantee amounting to Rs. 35,000/- which will be released after 10(Ten) years from the date of completion of the whole work. In case,the contactor fails to furnish the B.G.,equal amont i.e. Rs. 35,000/- will be kept withheld from the Security Deposit till the end of the Defect Liability Period.

-

-

-

... More
Total Area

405.36

-

190.7

... More
R.R.H.G. stone masonry in cement mortar ( 1 : 5 ) in foundation and plinth. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect excluding GST as directed by the Engineer-in-charge.

146.98

-

3377

... More
Fly Ash. brick masonry of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use ,including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the works complete in all respect excluding GST as directed by the Engineer-in-charge.

-

-

-

... More
BUILDING

-

-

-

... More
Foundation & Plinth

85.68

-

4039.9

... More
Superstructure

-

-

-

... More
Ground Floor

105.38

-

4073.2

... More
First Floor

119.22

-

4335.1

... More
Second floor

119.22

-

4636.2

... More
Compound Wall

136.35

-

4073.2

... More
First Class fly ash Brick Masonry for 125 m.m width brick masonry wall in cement mortar of mix (1:4) using Fly Ash bricks of size 25 c.m x 12 c.m x 8 c.m having crushing strength not less than 75 kg per square c.m with provision of 2 ( Two nos ) of 6 m.m dia M.S. Round Reinforcement Bars at each 4th layers) with cement and screened & washed sharp river sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, stacking, royalties of all materials ,cost of all labour, sundries, T&P required for the works etc. complete excluding GST in all respect as directed by the Engineer-in-charge.

-

-

-

... More
Ground Floor

12.51

-

4984.6

... More
First Floor

23.98

-

5246.4

... More
Second floor

19.77

-

5547.5

... More
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-25 Grade in all type of Concrete works( i.e footing, Plinth Band, Lintels, Chajja, Shelf fins, Roof slabs, Balconies, Staircase, Column, Beam Parapets, Window sills, Lofts, Railings etc. ) as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of required steel centering and shuttering there after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GST as directed by the Engineer-in-charge.

-

-

-

... More
BELOW PLINTH LVL.

-

-

-

... More
Footing

100.89

-

4924.6

... More
Plinth Beam

25.09

-

5287.1

... More
Lintel band

-

-

-

... More
Ground Floor

10.29

-

8448.5

... More
First Floor

10.47

-

8886.8

... More
Second floor

10.47

-

9452.4

... More
Column

-

-

-

... More
Ground Floor

32.04

-

10640.4

... More
First Floor

30.52

-

11580

... More
Second floor

30.52

-

12773.6

... More
Roof Beam

-

-

-

... More
Ground Floor

45.17

-

10640.4

... More
First Floor

47.14

-

11580

... More
Second floor

47.14

-

12773.6

... More
R.C.C. Chajja

-

-

-

... More
Ground Floor

21.51

-

786.4

... More
First Floor

12.51

-

845.8

... More
Second floor

12.51

-

922.4

... More
Stair Case

-

-

-

... More
Ground Floor

3.51

-

10128.1

... More
First Floor

3.51

-

11022.4

... More
Second floor

3.28

-

12155.3

... More
Roof slab

-

-

-

... More
Ground Floor

79.45

-

9100.3

... More
First Floor

74.46

-

9674

... More
Second floor

74.46

-

10409.2

... More
Compound Wall

-

-

-

... More
Plinth Beam

13.15

-

5287.1

... More
Providing & fixing Thermo mechanically treated bars (Fe-500 ) Reinforcement bars of approved make for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyance of reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour, loading, unloading, labour cess, T&P, etc. required for the work complete for the work in all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement)

-

-

-

... More
Ground Floor

390.33

-

7679.7

... More
First Floor

230.62

-

7703.1

... More
Second floor

230.62

-

7727.6

... More
Compound Wall

13.15

-

7679.7

... More
25 mm. thick Grading Concrete of proportion (1:2:2) on top of the Roof Slab using approved quality of cement, 6 mm. size hard crusher broken granite stone chips with screened & washed sharp sand for mortar of approved quality from approved quarry, washed & cleaned, free from all debrises and silt along with providing a layer of waterproofing treatment by using pedicrete (URP/SBR) Latex before grading concret (Mix - Latex @ 0.54 Ltr/Sqm & Cement @ 0.008Qntl /Sqm) including hoisting, lowering and laying concrete in all floors at all height after chipping, chiseling and cleaning the entire roof surface by using wire brush, finished smooth to proper required slope and gradient including cost, conveyance, royalties, loading, unloading,stacking of all Materials, cost of all Labour, T &P, Sundries, Watering ,Curing etc.required for the work complete in all respect excluding GST as directed by the Engineer-in-charge.

-

-

-

... More
Ground Floor

58.84

-

292.7

... More
Second floor

595.71

-

351.9

... More
Providing and applying in depth Concentrate crystalline based waterproofing coating & durability enhancement by crystallization to be supported by at least two national / international test reports showing clear scanning electron microscopic (SEM) photographs of dansified and mature crystals formation to plug all the capillary tracks and pores of the concrete permanently and permeability tested as per IS-2720 conducted by CBRI the concrete should not absorbed water more than 1.5 gms and not more than 1mm from the concrete surface. The product to be listed in ICC-ES evaluation report index January 2009, 2010 and 2011. The treatment to be carried out on the cleaned concrete surface as per manufacturer’s specification/data sheet. The application to be carried out with brush in one coat @0.80 Kg/Coat by using all safety equipments and necessary arrangements of scaffolding to reach the required height as per approved specification including cost,Conveyance,loading,unloading of all materials, cost of all labour,T&P, sundries, required period for the work complete in all respect as directed by the Engineer-in-charge as directed by the Engineer-in-Charge.

-

-

-

... More
Note: All the water proofing treatment shall be executed through a recognised agency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of 10( Ten ) years from the certified date of completion for the satisfactory performance of the entire water proofing system. The Defect Liability Period of the water proffing is Ten years.The contractor has to furnish bank guarantee amounting to Rs. 50,000/- which will be released after 10(Ten) years from the date of completion of the whole work.

-

-

-

... More
Roof Slab

-

-

-

... More
Ground Floor

58.84

-

582.31

... More
Second floor

595.71

-

582.31

... More
Providing and laying water proofing treatment in sunken portion of WCs,bathroom,roof area etc., by applying Two coat of Sika Top Seal 109HL compound @ 2.25kg/Sqm including cost,Conveyance,loading,unloading of all materials, cost of all labour,T&P, sundries, required period for the work complete in all respect as directed by the Engineer-in-charge as directed by the Engineer-in-Charge.

-

-

-

... More
First Floor

56.3

-

600

... More
Second floor

56.3

-

600

... More
Providing , Fitting & Fixing 16 mm thick Kota stone tile (above.10sqm) in flooring using special grade of Kota stone tile confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings in all floors at all height on 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the kota stone tile with neat white cement slurry, including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect excluding GST as directed by the Engineer-in-Charge.

23.2

-

826.7

... More
Providing, Fitting & Fixing of kota stone of approved quality and make confirming to IS specifications having minimum breaking strength 1400 kg/sq.cm in dados and skirting in all floors at all heights on 12mm thick bed of cement mortar(1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading, unloading, stacking,royalties of all materials, cost of all labour, T & P, sundries, watering & curing etc. required for the work complete in all respect excluding GST as directed by the Engineer-in-Charge.

3.48

-

842.9

... More
Supplying , fitting and Fixing vitrified Tile(Matt finish) flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm of approved quality, colour in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST as directed by Engineer-in-charge. (Note- Sample of tiles shall be approved before procurement and use.)

75.22

-

940

... More
Supplying , fitting and Fixing vitrified Tile(Matt finish) in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved quality in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days,including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification excluding GST and as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.)

11.28

-

1088.3

... More
Providing Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, ccolour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. complete in all respect excluding GST as directed by Engineer-in-charge(Note- Sample of tiles shall be approved before procurement and use.)

-

-

-

... More
Ground Floor

46.52

-

2164.4

... More
First Floor

14.4

-

2174.1

... More
Second floor

14.4

-

2184.2

... More
Providing ,Fitting and Fixing minimum 8 m.m to 10m.m thick Vitrified Tile in flooring using Vitrified Tile of approved quality, colour and size(600 m.m x 600 m.m coloured printed series homogeneous) in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Vitrified Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Vitrified Tile if required (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work ,Watering,Curing for required days including cleaning the flooring space manually etc. complete in all respect excluding GST as directed by the Engineer-in-charge. Note - Sample of tiles shall be approved before procurement and use.)

-

-

-

... More
Ground Floor

234.53

-

907.6

... More
First Floor

497.21

-

917.2

... More
Second floor

434.16

-

927.4

... More
Providing, Fitting & Fixing of 8 mm. to 10mm. thick Vitrified Tile ( of size 600 m.m x 600 m.m ) of NITCO or equivalent make confirming to IS specifications having minimum breaking strength 1400 kg/sq.cm in dados skirting and riser of steps in all floors at all heights on 12m.m thick cement mortar (1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading, unloading, stacking,royalties of all materials, cost of all labour, T & P, sundries, watering & curing etc. required for the work complete in all respect excluding GST as directed by the Engineer-in-Charge. Note - Sample of tiles shall be approved before procurement and use.)

-

-

-

... More
Ground Floor

23.45

-

1055

... More
First Floor

49.72

-

1069

... More
Second floor

43.42

-

1084.9

... More
Providing & Fixing tiles of size 20 x 30cm glazed ceramic wall tiles of premium grade of approved quality and shade having thickness 8mm to 10mm confirming to IS 13755 in dados skirting and risers of steps on 12mm thick cement plaster (1:3) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc including filling the joints with neat white cement slurry mixed with pigments to match the shade of the tiles including cost, conveyance,loading,unloading,stacking, royalities of all materials, cost of all labour,T&P, sundries, watering and curing for the required period for the work complete in all respect excluding GST as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.)

-

-

-

... More
Ground Floor

163.27

-

739.2

... More
First Floor

117.77

-

753.8

... More
Second floor

117.77

-

769.1

... More
Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring in toilets using special plain / printed series anti-skid ceramic floor tile of premium grade (having minimum thickness 7 mm to 8 mm & size 300 mm x 300 mm or 400 mm x 400 mm ) confirming to I.S 13755 of approved quility and shade on 20mm thick ded of cement morter of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the anti-skid ceramic floor tiles with neat white cement slurry, mixed with required (tiles are to be immersed in the water for required time before use) quantities of pigments of approved marks to match the shades of the anti-skid ceramic floor tiles if required including cost, conveyance, loading, unloading, stacking, royalties of all material, cost of all labour , sundries, T&P required for the work , watering,complete in all respect as per specification excluding GST aas per specification as directed by Engineer-in-charge.(Note- Sample of tiles shall be approved before procurement and use.)

-

-

-

... More
Ground Floor

53.66

-

677.1

... More
First Floor

54.02

-

686.8

... More
Second floor

54.02

-

696.9

... More
Providing minimum 16 m.m thick Chequered Tile Flooring using approved quality, shade & size of Chequered tile above 0.10 sqm in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar , grouted with neat white cement slurry joining the Chequered Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Chequered Tile if required, including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T&P required for the work,Watering ,Curing for required days including rubbing mechanically and wax polishing etc. complete in all respect excluding GST as directed by the Engineer-in-charge.

27.64

-

483.2

... More
12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete in all respect excluding GST as directed by the Engineer- in- charge.

-

-

-

... More
Ground Floor

503.18

-

127.4

... More
First Floor

492.37

-

132.4

... More
Second floor

492.37

-

137.7

... More
Compound Wall

537.88

-

127.4

... More
16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete in all respect excluding GST as directed by the Engineer- in- charge.

-

-

-

... More
Ground Floor

1035.12

-

192.5

... More
First Floor

1745.09

-

197.3

... More
Second floor

1745.09

-

202.3

... More
Compound Wall

596.34

-

192.5

... More
6 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect excluding GST as directed by the Engineer- in- charge.

-

-

-

... More
Ground Floor

562.03

-

151.3

... More
First Floor

693.46

-

155.1

... More
Second floor

693.46

-

159

... More
Finishing wall surface of walls with cement based wall putty ( water based) of approved make and finishing the surface smooth by sand papering to receive paint in all floor & at all heights including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as directed by Engineer-in-charge.

-

-

-

... More
Ground Floor

1035.12

-

70.81

... More
First Floor

1745.09

-

72.1

... More
Second floor

1745.09

-

73.5

... More
Distempering two coats to walls with distemper of approved shade on new work over a coat of approved (water bound) primer at all heights including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as directed by Engineer-in-charge.

-

-

-

... More
Ground Floor

1597.15

-

109.6

... More
First Floor

2438.56

-

112.5

... More
Second floor

2438.56

-

115.4

... More
Painting 2 (Two) or more coats with Weather Coat Paint of approved Brand / Quality & Colour on the finished external plastered surface using required quantities of paint as specified by the concerned manufacturer to give an even shade over a coat of cement primer(water bound) in all floors at all height , watering the surface before applying the Weather Coat Paint and curing for the required period including cost, coveyance, loading , unloading ,stacking of all Materials, cost of all Labour, Sundries ,Scafffolding ,Staging and T&P etc. required for the work complete in all respect excluding GST as directed by the Engineer-in-charge.

-

-

-

... More
Ground Floor

503.18

-

128.8

... More
First Floor

492.37

-

131.8

... More
Second floor

492.37

-

134.8

... More
Compound Wall

1134.22

-

128.8

... More
Providing and fixing of 35mm thick ISI marked factory made flush door shutters conforming to IS 2202 (Part-I) both side commercial of approved make , both faces of shutters finished with 1mm thick lamination , teak edge leaping to the periphery of shutter with polishing as per detail drawing with requsite glazing including, all hardwares & fixtures, SS brush finish cylindrical lock of Godrej / doorset or equivalent make ,tower bolt- 260 x 10mm & handle- 125mm with 175x 32mm, plate - 2 no, hinges -125mm x 70mm x 4mm -4 nos , door stopper etc. complete in all respect excluding GST as directed by the Engineer-in-charge.

-

-

-

... More
Ground Floor

49.22

-

3519.6

... More
First Floor

36.33

-

3519.6

... More
Second floor

36.33

-

3519.6

... More
Providing & fixing factory made single extruded WPC( Wood polymer Composite) solid flush door shutter of required size comprising of virgin polymer of k value 58-60 (Suspension Grade),calcium carbonate and natural fibers( wood powder/rice husk/wheat husk) and non toxic addictives ( maximum toxicity index of 12 for 100gms) having minimum denisity of 650 kg/cum and screw withdrawal strength of 1800N(Face) & 900 N(Edge), minimum compresive strength 50N/mm2,modulus of elasticity 850 n/mm2 and resistance to spread of flame of Class A Category with property of being termite/borer proof,water/moisture proof and fire retardant , and fixing with S.S butt hinges of 100mmx40mm size with necessary full body threaded star headed counter sunk S.S screws including one coat wood primer & two coat enmel paint as per drawing including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge.(28mm thickness)

-

-

-

... More
Ground Floor

20.48

-

3261.83

... More
First Floor

11.03

-

3261.83

... More
Second floor

11.03

-

3261.83

... More
Providing and fixing factory made uPVC white colour (FINESTA/ /KOMMERLING/ENCRAFT /equivalent)sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (including 5 mm thick plain Glass) Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) complete excluding GST.

-

-

-

... More
Ground Floor

68.04

-

6403.7

... More
First Floor

28.8

-

6403.7

... More
Second floor

28.8

-

6403.7

... More
Supplying, Fitting and Fixing M.S Grills / M.S shutter /M.S Gateof approved Drawings & Designs made out of M S Flat, Square bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming using approved quality metallic primer, making required holes in Massonary Walls / R.C.C Structures (where ever necessary) , grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips & making good to the damages of Massonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties of all Materials , cost of all Labours, Staging, Scaffolding, Sundries, T&P etc. complete excluding GST as directed by the Engineer-in-charge.( Weight to be taken up properly prior to fixing the grills in the works and payment to be made accordingly )

-

-

-

... More
Ground Floor

1521

-

85.76

... More
First Floor

549

-

85.76

... More
Second floor

549

-

85.76

... More
Compound Wall

180

-

85.76

... More
Providing and painting two coats with synthetic enamel paint on Iron work over a coat of Red Oxide Primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect excluding GST as directed by Engineer-in-charge.

-

-

-

... More
Ground Floor

60.84

-

187.6

... More
First Floor

21.96

-

190.7

... More
Second floor

21.96

-

195.7

... More
Providing & fixing factory made single extruded WPC( Wood polymer Composite) solid door /windows/other frames/chowkhat of required size comprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers( wood powder/rice husk/wheat husk) and non toxic addictives ( maximum toxicity index of 12 for 100gms)fabricated with miter joints after applying PVC Solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 900kg/cum, screws withdrawal minimum stregth of 2200 N(Face) & 1100 N(Edge), minimum compresive strength 58N/mm2,modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A Category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners 6 nos. 10mm dia ,150mm length of Hilti/Fischer anchor fasteners including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect excluding GST as directed by the Engineer-in-charge.

-

-

-

... More
125mmx65mm

-

-

-

... More
Ground Floor

110.35

-

790

... More
First Floor

97.1

-

790

... More
Second floor

97.1

-

790

... More
75mmx50mm

-

-

-

... More
Ground Floor

44.85

-

507.79

... More
First Floor

34.65

-

507.79

... More
Second floor

35.65

-

507.79

... More
Supplying, Fitting and Fixing of Stainless Steel of 304 grade in Handrail using 50mm dia of 2mm thick circular pipe with stainless steel balustrade of size 32 m.m x 32 m.m x 2 m.m @ 0.90mtr.centre to centre and stainless steel square pipe bracing of size 32m.m x 32m.m x 2m.m in 3 (Three) rows in stair case and at required places as per approved Drawings, Design and Specification,welding, buffing, polishing etc with cost, conveyance,loading,unloading ,stacking of all materials,cost of all labour, T&P etc. required for the work complete in all respect excluding GST in all floors at all height as directed by the Engineer-in charge.

981.1

-

333.72

... More
Providing & filling sunken floors with broken A.A.C block well compacted and top surface dressed and levelled to proper gradient as per direction including hoisting, lowering, laying and compacting, watering , including cost conveyance, royalities of all material, cost of all labour for loading and unloading, T & P etc sundries required for the work etc complete excluding GST as directed by the Engineer-in-Charge

44.78

-

1620.2

... More
Providing, Fitting & Fixing 110 m.m Dia PVC Rain Water Down Pipe of approved specification, brand / make & gauge in proper position & plumb complete including cost, conveyance,loading,unloading,stacking of all Materials ,cost of all Labour, T&P ,Sundries,Staging, Scaffolding required for the work etc. complete in all respect excluding GST as directed by the Engineer- in -charge.

130

-

171.3

... More
Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing(with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:

-

-

-

... More
Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III(the ststem must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminimum sections for fixing glazing panels of various thickness, aluminimum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop(barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire harzard including:

-

-

-

... More
Fabricating and supplying serrated M.S. hot dip galvanised/Aluminimum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/Masonary/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contracts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.

-

-

-

... More
Providing and filling two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory/workshop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.

-

-

-

... More
Providing and fixing in position flashing of solid aluminimum sheet 1mm thick and of sizes, shapes and profiles, as requirede as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
Making provision for drainage of moisture/water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom(if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of glazed units , T&P , scaffolding and other incidental charges including wastages etc. , enabling temporary structures and services , cranes or cradles etc. as describe above and as specified. The item includes the cost of getting all the structural and functional design include shop drawings checked by a structural designer , dully approved by Engineer-in-charge. The item also includes the cost of all mocks ups at site, cost of all samples of the individual components for testing in an approved laboratory , field tests on the assembled working structural glazing as specified , cleaning and protection till the handling over the building for occupation. In the end ,the Contractor shall provide a water tight structural glazing as specified , cleaning and protection till the handiling over the of building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. complete as required ,as per Architectural drawings, as per item description , as specified as per the approved shop drawing and as directed by the Engineer-in-Charge.

-

-

-

... More
The cost of providing extruded aluminium frames , shadow boxes , extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However ,for the purpos e of payment ,only the actual area of structural glazing (including width of grooves) on external face shall be measured in sqm. up to two decimal places.

-

-

-

... More
Following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 sqm from the certified laboratories accreditation Board for Testing and Calibration Laboratories),Department of Science & Technologies , India. Cost of testing is payble separately . The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of test and importance of the work . Performance Testing of structural glazing system tests to be conducted in the NBL Certified laboratories

-

-

-

... More
1.Performance Laboratory test for air leakage Test (-50pa to -300pa ) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr".

-

-

-

... More
2.Static Water penetration Test. (50pa to 1500pa) as per ASTME-331-09 testing method for a range upto 2000 ml."

-

-

-

... More
3.Dynamic Water Penetration (50pa to 1500pa)as per AAMA 501.01-05 testing method for a range upto 2000ml"

-

-

-

... More
4.Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50mm".

-

-

-

... More
5.Seismic Movement Test (upto 30mm) as per AAMA 501.4-09 testing method for qualitative test"Tests to be conducted on site.

-

-

-

... More
6.Onsite Test for Water Leakage for a pressure range 50kpa to 240 kpa (35psi) upto 2000ml".

-

-

-

... More
The item of work inclusive of cost and conveyance of all materials, fittings, fixtures, cost of all labour,sundries, T&P, scaffolding/staging required for the work all complete as per the direction of Engineer-in-charge.

-

-

-

... More
AT ALL LEVELS

38.04

-

2535.1

... More
Providing & supplying Glass Panel comprising of 6mm thick heat strengthened soft coated reflective glass of approved colour and shade with reflective soft coating on surface #2 of approved colour and shade etc,all complete for the required performances as specified , as per the architectural drawing , as per the approved shop drawings, as specified, and as directed by the engineer - in - charge. For payment , only the actual area of glass on face #1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of glass panels in the curtain glazing is included in cost of relevent item*)

-

-

-

... More
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of Saint - Gobain make having properties as visible Light transmittance (VLT) of 40to 45 %, Light reflection internal 10 to 15%, light reflection external 10 to 15 %, shading coefficient (0.25-0.29) and U value of 1.6 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

-

-

-

... More
The item of work inclusive of cost and conveyance of all materials, fittings, fixtures, cost of all labour, sundries, T&P, scaffolding/staging required for the work all complete as per the direction of Engineer-in-charge

-

-

-

... More
AT ALL LEVELS

38.04

-

3715.4

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

125.49

-

597

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C HUME PIPE jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:

50

-

964.13

... More
Supplying & Fixing of GFRC jalli as per the architectural requirement ) to be fixed for direct application on the wall ,there will not be a over lapping make in position with necessary accessories with scafolding complete in all respects as per the direction of Engineer-in-charge.

3.51

-

4982.84

... More
Electrical Works(Internal)

-

-

-

... More
 A- WIRING

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessedmedium class PVC conduit, with modular switch, modular plate, suitable GI box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required as per direction of Engineer in-charge.

-

-

-

... More
Group-C (Single Light Point)

294

-

666

... More
Group-C (Fan point)

105

-

666

... More
Group-C (Exhaust fan point)

40

-

666

... More
Wiring for group controlled (looped) light point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. as per drawing and as per the direction of Engineer in charge

-

-

-

... More
Subsequent point of group control. Group-C

108

-

374

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. as per drawing and as per the direction of Engineer in charge

115

-

297

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular modular switch, connections etc. as required.socket outlet and 15/16 A modular switch, connections etc. as required. as per drawing and as per the direction of Engineer in charge

17

-

380

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. as per drawing and as per the direction of Engineer in charge

131

-

457

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections for AC Plug Points, painting etc. as required. as per drawing and as per the direction of Engineer in charge

2

-

508

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. as required and as per direction of Engineer-in-charge.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(6A Switch Socket)

200

-

99

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(BDB-L to Switch Board ,15A Switch Socket, 2nos 6A Switch Socket , 6A Switch Socket & Street Light)

1100

-

119

... More
2X 4 sq. mm + 1X 4 sq. mm earth wire(BDB -to AC)

30

-

148

... More
2X 6 sq. mm + 1X 6 sq. mm earth wire(MDB to BDB-L4 GF ,FDB to BDB-L1 1.F/2.F/3.F & BDB-L3 3F) BDB-TERRACE FLOOR)

180

-

192

... More
4X 6 sq. mm + 2X 6 sq. mm earth wire(MDB to BDB-L1,L2,L3 (GF) / FDB to BDB-L2,L3,L4 (1F & 2F) / BDB-L2(3.F)

370

-

317

... More
4X 10 sq. mm + 2X 6 sq. mm earth wire(MDB -to FDB) )

100

-

446

... More
B-Data Point & TV POINT

-

-

-

... More
Supply, delivery and laying of following sizes of 2mm wall thick PVC conduit with required accessories concealed under floor / in wall / column / roof slab above the false ceiling of the building alongwith other accessories and 18 swg GI fish wire complete for Telephone / Data point wiring etc as required and as per direction of Engineer-in-charge.

-

-

-

... More
25mm dia (TV & DATA)

100

-

59

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
RJ 45 UTP information outlet.

1

-

816

... More
TV outlet Socket

2

-

89

... More
Supplying and fixing modules, GI box alongwith modular base & cover plate for modular switches in recess. as required. as per direction of Engineer-in- charge

-

-

-

... More
2 Module (75mmX75mm)(Data Point)

3

-

162

... More
Supplying and drawing of 1run of UTP 4 pair CAT 6 LAN Cable for Data Point in the existing surface/ recessed Steel/ PVC conduit as required

100

-

38

... More
SCHEDULE- C-CABLING WORK

-

-

-

... More
Supply, Laying & testing of following size of PVC insulated, PVC sheathed, round/strip armoured aluminium conductor power cable of 1100 volt grade clamped on surface of wall/ column/ existing RCC/ stone ware/ masonry cable trench/ cable trey/ through G.I. pipe/ hume pipe as the case may be, including cost of saddles/ clamps/ markers etc but excluding the cost of G. I. pipe/ hume pipe compete with making good the damages caused and returning the balance unused cables to stores as required and as per direction of Engineer-in-charge.

-

-

-

... More
3 1/2 core x 120 sqmm A2XFY(Cable from S.S PANEL to MDB & DG to MDB laying inside Hume Pipe)- L.S

200

-

794

... More
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.as per direction of Engineer-in-charge

-

-

-

... More
3 1/2 core x 120 sqmm A2XFY

4

-

345

... More
SCHEDULE- D-DISTRIBUTION BOARDS

-

-

-

... More
Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type distribution boards made out of 2 mm thick CR sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade; dust, damp & vermin proof ; having hinged door and compartmental arrangement for each equipment & busbar chamber on the top of the panel running horizontally; having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.

-

-

-

... More
(a)MDB

-

-

-

... More
Incomer:1 & 2 -160A 3P MCCB(36kA)+NL .with adjustable thermal setting+NL

-

-

-

... More
1no 200A On load Change over Switch

-

-

-

... More
Busbar : 4nos 25 X 6mm E.C.Strips

-

-

-

... More
Instruments: 1 Set of 0-500volt Digital voltmeter with inbuilt selector switch & 1 set of LED type phase indicating lamps with control fuses

-

-

-

... More
1 No 0-160A digital ammeter with inbuilt selector switch & required CT's

-

-

-

... More
4Nos each of . 50-kA VSP along with 32 Amp 1P MCB backup protection

-

-

-

... More
ON' 'OFF' TRIP indication lamp

-

-

-

... More
Outgoing: 4Nos 40A 3PN MCB 'C' (10kA)

-

-

-

... More
4Nos 25A 3PN MCB 'C' (10kA)

-

-

-

... More
6Nos 25A 2P MCB 'C' (10kA)

-

-

-

... More
Complete duly factory wired as per SLD

1

-

199600

... More
(b)FDB-L(1.F /2.F)

-

-

-

... More
Incomer: 40A 4P MCI

-

-

-

... More
Bus bar: 4 nos. 20x3mm E.C strips

-

-

-

... More
Outgoing: 4Nos 25A 3PN MCB.'C' (1okA)

-

-

-

... More
3Nos 25A 2P MCB.'C' (1okA)

-

-

-

... More
Instruments: 3 nos.LED type phase indicating lamps with control fuses

-

-

-

... More
Complete duly factory wired as per SLD

2

-

22200

... More
FDB-L(3.F)

-

-

-

... More
Incomer: 40A 4P MCI

-

-

-

... More
Bus bar: 4 nos. 20x3mm E.C strips

-

-

-

... More
Outgoing: 2Nos 25A 3PN MCB.'C' (1okA)

-

-

-

... More
3Nos 25A 2P MCB.'C' (1okA)

-

-

-

... More
Instruments: 3 nos.LED type phase indicating lamps with control fuses

-

-

-

... More
Complete duly factory wired as per SLD

1

-

14800

... More
Supply, delivery, installation, testing & commissioning of L.T. indoor floor wall mounted type distribution boards of original factory made enclosures of the same brand as per MCB conforming to the relevant ISS and as per special conditions of contract, making good the damages caused complete as per the direction of Engineer-in-charge

-

-

-

... More
BDB-L1, L2, L3(G.F) / BDB-L2,L3,L4(1.F) / / BDB-L2,L3,L4(2.F) / BDB- L2(3.F)

-

-

-

... More
Incoming: 1 No 32A 4P MCI

-

-

-

... More
Outgoing : 3 Nos 25A 2P RCCB (100mA) each followed 4 Nos 6-32 Amp 1P MCB 'C' as per SLD

-

-

-

... More
Complete duly factory wired as per SLD

10

-

26500

... More
BDB-L4(GF) / BDB-L1 (1F) / BDB-L1(2.F)/ BDB-L1, L3 (3.F) ( 12way SPN DB)

-

-

-

... More
Incoming: 25A 2P RCCB (100mA)

-

-

-

... More
Outgoing : 8Nos 6-32 Amp 1P MCB 'C' as per SLD

-

-

-

... More
Complete duly factory wired as per SLD

5

-

8900

... More
BDBTerrace Floor ( 8way SPN DB)

-

-

-

... More
Incoming: 25A 2P RCCB (100mA)

-

-

-

... More
Outgoing : 4Nos 6-32 Amp 1P MCB 'C' as per SLD

-

-

-

... More
Complete duly factory wired as per SLD

1

-

7200

... More
E-FITTINGS & FIXTURES

-

-

-

... More
Supply of 1x15 watt LED lamp similar to Havells NU BULB Plus 15 W 865 B22 3 STAR LED Bulb Existing Angle/batten holder or equivalent

91

-

335

... More
Supply of 10 watt LED Batten Tube fitting similar to PHILIPS Catalogue No - BN021 LED 12S 6500PSUGR or equivalent

98

-

478

... More
Supply of 20 watt LED Batten Tube fitting similar to PHILIPS Catalogue No - BN021C LED22S PSU CW GR or equivalent

188

-

712

... More
Supply of 12watt LED Recessed down light similar to Philips Catalogue No - SM250C LED 12S-6500PSUWH or equivalent complete etc.

21

-

1006

... More
Supply of 14W LED Bulk Head light similar to Philips Catalogue WT140W LED7S CW PSU S1PC or equivalent complete etc.as required.

4

-

837

... More
Supply of 1200mm (48") 5 Star rated Ceiling Fan similar to HAVELLS Efficiencia Neo (BLDC 26 W) 5 Star Ratings or equivalent complete.

105

-

3250

... More
Supply of 300mm Exhause Fan similar to HAVELLS Catalogue Turbo single Phase ISI, 1400rpm or equivalent complete etc.as required.

40

-

3217

... More
Supply delivery, installation, testing & commissioning of following types of 45W LED Street light similar to PhilipsCatalogue BRP052 LED 045CW SLMR FG S1 PSU or equivalent complete etc.as required.. as per drawing and as per the direction of Engineer in charg

10

-

6097

... More
F-INSTALLATION OF FITTING FIXTURE

-

-

-

... More
Supply and fixing circular/ HEXAGONAL G.I. box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the G.I. box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

105

-

143

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, . as required, as per drawing and as per the direction of Engineer in charge

105

-

99

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate or existing sheet metal switch board switch box including connections but excluding Cover plate etc. as required. as per drawing and as per the direction of Engineer in charge

105

-

282

... More
Supplying and fixing PVC batten/ angle holder including connections and fixing of bulb etc. as required, as per drawing and as per the direction of Engineer in charge

91

-

59

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required as per drawing and as per the direction of Engineer in charge

311

-

55

... More
Installation of exhaust fan(Upto 450 mm sweep)in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, as per drawing and as per the direction of Engineer in charge Sub Total (Installation of Fitting Fixture):-

40

-

214

... More
G-Earthing

-

-

-

... More
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and as per the direction of Engineer in charge

2

-

4785

... More
Supply of materials and laying of 25 x 5 mm GI flat laid under ground including cost of jointing by welding, nut bolts, bituminous tape & bituminous paint, labour charges for excavation of trench in all kinds of soil etc complete as required from earthing electrode upto the GF of Elect room & then GF to 2F as earthing busbar.etc.

100

-

143

... More
Supply of materials and laying under ground / floor / wall including making end termination and testing of 6 swg G.I. wire for loop earthing of equipments, switch boards & panels as required complete as per direction of Engineer-in-charge.

50

-

25

... More
H-LIGHTNING PROTECTION

-

-

-

... More
Supplying and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required and as per the direction of Engineer in charge.

9

-

310

... More
H2 Supplying and fixing 25 mm X 5 mm G.I. strip on surface for roof conductor etc. as required and as per the direction of Engineer in charge.

220

-

143

... More
Supplying and fixing 25 mm X 5 mm G.I. strip on surface of wall for down conductor etc. as required and as per the direction of Engineer in charge.

100

-

375

... More
Supplying and laying G.I. Strip 32 mm X 6 mm from earth electrode directly in ground for ground conductor as required and as per the direction of Engineer in charge

200

-

114

... More
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and as per the direction of Engineer in charge

9

-

4785

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand)

-

-

-

... More
100mm RCC Hume Pipe (S/S & DG to MDB)

200

-

352

... More
SAFETY EQUIPMENTS FOR ELECTRICAL ROOM

-

-

-

... More
Supply and hanging of shock treatment chart duly bound/laminated.

1

-

1000

... More
Supply and installation of 3 Nos. fire buskets on a mild steel stand complete as per specification and requirement of fire safety provisions.

1

-

3000

... More
Supply & installation of 5-Kg capacity dry CO2 type fire extinguisher complete as required

1

-

5000

... More
Supply & installation of 5-Kg capacity ABC powder type fire extinguishercomplete as required

1

-

5500

... More
Supply & installation of 1100volt grade ISI marked insulating rubber mat complete as required

10

-

450

... More
First aid box With first aid kits such as( Gauze pads (at least 4 by 4 inches, Two large gauze pads (at least 8 by 10 inches), A box of adhesive bandages, One gauze roller bandage, Two triangular bandages., Wound cleaning agent.,Scissors At least one blanket., and Anti-Septic Cream Complete as required

1

-

5000

... More
Supply and installation of 440-volt danger notice plate

4

-

250

... More
P.H WORKS ( INTERNAL)

-

-

-

... More
Providing all materials, labour, T&P for laying/fixing of following dia CPVC pipes SDR-11 as per IS-15778/2007 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHRIVAD/AJAY/SUPREME

-

-

-

... More
20mm dia

90

-

233.51

... More
25mm dia

203

-

308.05

... More
32mm dia

25

-

446.42

... More
40mm dia

90

-

602.97

... More
Providing all materials, labour, T&P for laying/ fixing of following dia uPVC solvent welded pipes Sch-80 as per ASTM-D-1785 including fixing of required size uPVC Schedule-80 fittings as per ASTM D-2467 like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAY/SUPREME

-

-

-

... More
50mm dia

50

-

535.3

... More
Providing all materials, labour, T&P for laying/fixing of following dia uPVC pipes as per IS-13592:2000 with ISI mark of Type-B (1.7-2.1 kgf/cm2 & class-3) including fixing of required size uPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. (As per Cat no.2169212 of Ashirvad pipes HSN Code:3917)

-

-

-

... More
50mm dia

80

-

535.3

... More
Providing all materials, labour, T&P for fitting & fixing of following CPVC Ball Valves(CTS Sockets) confirming to IS-15778 with ISI mark as per ASTM D-2846 in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of all taxes,duties,transportation scaffolding etc. all complete as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAY/SUPREME

-

-

-

... More
25mm dia CPVC ball valve

12

-

736.29

... More
32mm dia CPVC ball valve

5

-

1207.96

... More
40mm dia CPVC ball valve

5

-

1862.44

... More
Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of materials, curing, conveyance, taxes of all materials etc. all complete as per specification & direction of EIC.

275

-

179.78

... More
Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking pipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-in-charge.

-

-

-

... More
For 15mm to 50mm dia pipe to pass in 125mm to 250mm thick wall

20

-

44.44

... More
For 75mm to 150mm dia pipe to pass in 250mm thick wall

15

-

245.43

... More
Providing all labour,T&P and cutting holes in RCC chajja/roof/floor for taking pipes through and making good the damages with supply of all required materials etc. complete as per the direction of the Engineer-in-charge.

20

-

155.54

... More
Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china water closet (European pattern) 'P' or 'S' type of approved make as per IS-2556 with ISI mark in all floor including supply of sutaible PVC wall plug and Brass screws etc. all complete including cost of PVC seat cover (solid) with hinges & rubber buffers including testing etc. all complete with all cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make : HINDWARE/CERA/PARRYWARE

-

-

-

... More
European water closet (As per Cat no:20087 of Hindware)

21

-

3416.83

... More
Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china water closet (Indian pattern) 'P' or 'S' type of approved make as per IS-2556 with ISI mark in all floor including supply of sutaible PVC wall plug and Brass screws etc. all complete including cost of PVC seat cover (solid) with hinges & rubber buffers including testing etc. all complete with all cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make : HINDWARE/CERA/PARRYWARE

-

-

-

... More
Indian water closet (As per Cat no:20070 of Hindware)

5

-

2636.1

... More
Providing all materials, labour, and T&P for fitting and fixing of PVC low level cistern complete with all internal fittings of approved make as per IS-7231 with ISI mark in all floor and providing of necessary PVC wall plug, screws and 15mm dia PVC water connecting pipe with union at both end including testing etc. all complete as per specification & direction of Engineer-in-charge.Make:HINDWARE/CERA/PARRYWARE

-

-

-

... More
PVC low level Cistern .(As per Hindware Sleek Fresh ISI)

26

-

1912.44

... More
Providing all materials, labour, T&P for fitting and fixing of white glazed vitreous china water closet (European pattern) 'P' or 'S' type with cistern & seat cover, wash hand basin of size 460mmx360mm with one pair basin bolt, one no. hinged rail 760mm long & 4 nos. grab rails 600mm long including supply of sutaible PVC wall plug and Brass screws etc. suitable for handicapped toilets in all floor etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make:HINDWARE/CERA/PARRYWARE

-

-

-

... More
Handicapped Toilet with all acessories . (As per Cat-70002 of Hindware matrix set)

1

-

81738.29

... More
Supply all materials and labour for fitting and fixing of following size white glazed vitreous china wash hand basin with half pedestal of approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete etc. including all taxes, duties, transportation etc. all complete as per direction of EIC. (Make:HINDWARE/CERA/PARRYWARE).

-

-

-

... More
Wash Hand Basin with Pedestal of size (550x400 mm) . ( As per Cat:10099 & 11032 of Hindware)

25

-

6329.96

... More
Providing all materials, labour, T&P for fixing of following sizes of bevelled edge mirror of 5mm thick mounted on 6mm thick AC back sheet & CP cup screw with PVC wall plugs in all floor including cost, conveyance, taxes of all materials complete as per specification and direction of E.I.C. Make-Saint gobain/Golden Fish.

-

-

-

... More
600mm x 450mm size

25

-

771.64

... More
Providing all materials, labour,T&P ,fittings and fixing of different water supply (CP on Brass) fitting (Quarter Turn or as specified) as per IS specification & approved make in all floor of following sizes and specification with leak proof threaded joints with thread seal tape or any other method as required and directed including all taxes, duties, transportation etc., testing and rectification of defects after testing complete as per direction of Engineer-in-charge.

-

-

-

... More
15mm dia Long Body Bibcock with wall flange. (As per Cat no:CON-107KN of Jaquare )

9

-

1169.58

... More
20mm dia concealed stop cock with adjustable wall flange . (As per Cat no:CON-069 FTK of Jaquare )

9

-

676.7

... More
15mm dia Angle Stop cock with wall flange. (As per Cat no : CON-053KN of Jaquare )

57

-

946.77

... More
15mm dia Pillar cock (As per Cat no:CON-021 KN of Jaquare)

33

-

1399.86

... More
15mm dia 2 way Bibcock with wall flange. (As per Cat no:CON-107KN of Jaquare )

21

-

1169.58

... More
O.H. Shower with Shower Arm & Wall flange. (As per Cat no : OHS-1709 of Jaquare )

9

-

3669.13

... More
C.P. Soap Dish Holder . (As per (MAKE-Jaquare of Cat no:ACN-1131N )

63

-

842.81

... More
Towel Ring .(As per -Jaquare of Cat no:ACN-1121N )

27

-

1087.57

... More
CP Towel Rail of 600mm long. (As per Cat no-ACN-1111SM of Jaquare)

9

-

1604.89

... More
600mm long Glass Self.(As per Cat noACN-1171N of Jaquare)

25

-

1507.32

... More
Health Faucet ABS SS braided hose 1.00m with CP hook . (As per Cat no:ALD-579 of Jaquare)

21

-

1677.61

... More
15mm dia sink cock with swivel casted spout (Wall mounted).(As per Cat no:CON-347 -KNM of Jaquare)

2

-

1771.24

... More
32mm dia C.P.waste (Half Threaded) (As per Cat no:CON-709 of Jaquare).

27

-

545.4

... More
127X127 mm stainless steel hinged grating (As per Cat no.FT-41 of Prayag)

54

-

617.11

... More
15mmx50mm C.P. Extension piece (As per Cat no.F8070301 of CERA))

77

-

130.29

... More
Toilet Paper Holder. (As per Cat no:F840008 of Hindware)

22

-

804.97

... More
32mm dia C.P. Robe Hook (As per Cat. No. ACN-1191N of jaquare)

21

-

384.81

... More
15mmx450mm Braided Hose Connection Pipe with both side Nuts & Rubber Washers. (As per Cat. No-F8070402 of CERA)

57

-

567.62

... More
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as per specification & direction of the Engineer-in-charge. Make: ASTRAL/ASHIRVAD/SUPREME/AJAY.

-

-

-

... More
110mm dia pipe

772

-

767.6

... More
Supplying all materials, labour, T&P, fitting and fixing of following dia uPVC SWR (Co-moulded Ring type) fittings of approved make confirming to IS-14735 with ISI marked in all floor with all taxes, duties, transportation & requisite testing as per specification & direction of EIC. Make:ASTRAL/ASHIRVAD/SUPREME/AJAY.

-

-

-

... More
110mmX110mm P Trap

54

-

423.19

... More
110mmx87.5º Plain bend

57

-

208.06

... More
110mmx87.5º door bend

52

-

249.47

... More
110mmx45º Plain Bend

86

-

172.71

... More
110mm dia Single Tee

31

-

262.6

... More
110mm Single Tee with Door

25

-

354.51

... More
110mm Cross Tee with Door

12

-

409.05

... More
110mm dia single 'Y'

75

-

352.49

... More
110mm dia single 'Y' with Door.

12

-

440.36

... More
110mm dia Vent cowl

7

-

65.65

... More
PVC Clamp Suitable for 110mm dia pipe

100

-

98.98

... More
110mm WC Connector(Straight)

21

-

409.05

... More
110mm Coupler

19

-

173.72

... More
End Plug

20

-

134.33

... More
Providing all materials, labour, T&P for fitting & fixing of following sizes of Stainless Steel Kitchen Sink made out of 0.8mm thick sheet with coupling & strainer, the flat boards for correct sandwitch between the platform top & granite/marble slab & making good the damages, fixing of 32mm dia PVC waste pipe etc. including testing, commissing all complete as per specification & direction of the Engineer-in-Charge.

-

-

-

... More
Stainless Steel Kitchen Sink of overal size-510 x 1040 x 200mm . Make-NIRALI (small) of popular range, satin.

1

-

11150.4

... More
Providing, Fitting,fixing including ,testing & Commissioning of following capacity polyethylene moulded water storage cylindrical tank including cutting holes of required size & shape & Providing, fitting and fixing of CPVC Water tank connector/Adaptor with jam nut etc. for filling,delivery,overflow & wash out arrangements,including hoisting upto required height above the ground level & placing the tank of required position (excluding construction of RCC pedestal upto 600mm ht. from the terrace with RCC (M-25) base slab,beam of approved design & 125mm thick brick masonary wall upto 2/3 ht. of tank (all round) in CM 1:4,12mm CP 1:4 over Brick work etc) all complete as per Specification & direction of EIC..

-

-

-

... More
2000 Litres Capacity Polyethylene moulded water storage tank with lid & locking arrangement as per IS-12701/1996 with ISI mark (Drinking & Flushing).

8

-

23289.78

... More
Float valve

8

-

803.96

... More
Supply, installation,testing & commisioning of water cooler cum purifier with chiller in floor of following capacity:60/80 SS including fixing the same on the floor with necessary water connection & waste arrangments with all labour, T&P etc.all complete as per the specification & direction of EIC. (As per Model :AG Green pure Chill 80SS of Aquaguard)

-

-

-

... More
Aquaguard Green storage cooler-cum-purifier

5

-

87331.67

... More
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B) of approved make confirming to IS-13592/1992.with ISI Mark in all floor.(Make:Astral/Ashirvad/Ajay)

-

-

-

... More
110mm dia pipe.

600

-

767.6

... More
110mm dia 45º BEND

50

-

617.11

... More
110mmx87.5º door bend.

50

-

249.47

... More
110mm Push Fit Coupler.

100

-

173.72

... More
PVC Clamp Suitable for 110mm dia pipe.

400

-

85.85

... More
150mm RCC NP2 Pipe (courtyard to outside drainage)

40

-

665.59

... More
Supplying all material labour , T&P for providing Water proofing to the sunken slab with Surface preparation i.e Cleaning the surface thoroughly by wire brush , mechanical grinder for making it free from all loose particles , dust etc . Then total cleaning through air blower followed by water jetting and then allowing the surface to dry and Supply and application of NANO technolodgy organo silane based zycosil+@ 1:20 (one part Zycosil+ and 20 parts of clean water ) to the saturation level on the entire flat surface and upto to the height of the sunken slab casted and then allowing for drying 24 hrs , test the surface for hydrophobicity . (All the waterproofing treatment (i.e for sl no- 225& 226 ) shall be excuted through a recognised water proofing agency approved by the E-I-C .

176.15

-

444.4

... More
Providing & filling sunken slab with 40mm size brick bat with overbrunt kiln brunt bricks including filling , compacting , watering , levelling the same as per the direction of E-I-C with all material, labour , scafolding , tools , plant for complete .

69.22

-

606

... More
N.B - The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.