Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Odisha Cooperative Tasar And Silk Federation Limited Tender
Eprocure
Opening Date28 May 2020
Closing Date10 Jun 2020
Tender Amount₹ 20,61,914 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 20,640Document Cost
₹ 7,080Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_SERIF_61269_1Bid Award Id
ViewTender No
VI-30(05)/SERIFED/2019-20/ 339Tender Authority
Odisha Cooperative Tasar And Silk Federation Limited ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling and removing R.C.C. Chajja, Shelves, fins and parapet including stacking the useful materials for reuse and removing the debris within 50m lead including loading and unloading as required as per site condition etc. complete as per specification and as directed by Engineer-in-Charge
8.1
-
-
Providing Fly Ash Brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength Each Not less than 75 Each Kg. Per. Sqr. Cm. in cement mortar of mix(1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar in foundation, plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as per specification and direction of Engineer-in-charge.
2.25
-
-
Providing 16mm thick cement plaster (inside )in all floors at all height with cement mortar of mix (1:6) with Portland slag cement (PSC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer-in-Charge.
1359.6
-
-
Providing 12mm. thick cement plaster (out side) with cement mortar of mix (1:6) in all floors with Portland slag cement (PSC) with neat cement punning and two coats of bitumen painting over top of the walls complete including watering and curing along with the cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as directed by the Engineer–in-Charge.
54
-
-
Supplying, fitting ,fixing vitrified tile of ( Printed ) in floors of size 600mmx600mm of approved make conferming to IS:13755 laid on 20mm thick cement mortar (1:4) (1 cement:4 sand) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry joining the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties, cost of all labour, sundries, T&P required for the work complete in all respect as per specification and direction of Engineer-in-charge.
20
-
-
Supplying, fitting and fixing of M.S. grill in windows including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
573.3
-
-
Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of primer with water bond cement primer in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
3673.62
-
-
Wall painting two coats with 100% Acrylic emulsion paint (1st quality) exterior grade of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of primer with water bond cement primer in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
705.6
-
-
2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips. On new work including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 2.5 cm thick in each layer including cost, conveyance, loading, unloading, royalties, cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per specification and direction of Engineer-in-charge.
1909.44
-
-
Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer.
336
-
-
Dressed seasoned sal wood work framed and fixed (wrought and put up) in trusses, purlines frames of doors, windows, ventilators and beams.
0.38
-
-
Supplying fitting and fixing in position flush door shutter of 32mm thick with 1mm Laminate of approved quality and as per drawing & design with all necessary brass fittings, door closer (godrej, heavy duty) motrice lock (godrej heavy duty), including cost of all materials, labour, all taxes, transportation, loading & unloading etc. complete as per specification and direction of Engineer –in-charge.
18.9
-
-
Providing, fitting and fixing fully glazed uPVC (2/3 track) windows/ventilators with necessary fittings, fixtures and hardwares like concealed locks ,handles, etc., glazed with 5mm thick toughened glass from saint gobain without any surface deformation, with sun reflective film, as per the drawing and design, and fixed to the walls or columns with lugs in cement concrete 1:2:4 cutting holes and mending good to all damages, including filling gaps if any, between the frames walls/ columns, with best quality sealant, including cost of all materials, labour, conveyance, royalties, scaffolding, sundries, tools and plants, etc., but excluding GST, complete as per the direction of the Engineering-in-charge/Consultant.
31.68
-
-
Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.
4
-
-
Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. Average Length: 3 mtr
4
-
-
Recessed wiring to ceiling fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked and stepped modular Regulator ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. Group C
6
-
-
Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer in Charge.
2
-
-
Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge.
4
-
-
Recessed wiring for 6 pin 16 amp socket outlet with 5Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.
2
-
-
Recessed wiring for A.C socket outlet with 20 amp SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure indusrial socket ,20A SP MCB including all accesories and connection as per direction of Engineer in Charge.
2
-
-
Recessed wiring to submain in 4 x 16sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(For P DB )
5
-
-
Recessed wiring to submain in 4 x 10sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(For PDB )
2
-
-
Recessed wiring to submain in 4 x 6sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(For LDB )
10
-
-
Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For LDB )
25
-
-
Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
10
-
-
Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
25.14
-
-
Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
60
-
-
Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator)
-
-
-
4 way (4 + 12 ), TPN , MCB DB double door horizontal type
4
-
-
Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland
plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with
out MCB/ RCCB/ ISOLATOR)
-
-
-
8 Way SPN double door, MCB DB
4
-
-
Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
-
-
-
6 amp to 32 amp rating SP MCB , "c" series, 10KA breaking capacity
2
-
-
Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
-
-
-
25 amp rating DP RCBO, 100/300 mA
1
-
-
25 amp rating FP RCBO, 100/300 mA
1
-
-
63 amp rating FP RCBO, 100/300 mA
1
-
-
CABLE .
-
-
-
Supply of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required.
-
-
-
3.5 C x 50 sq.mm Al
60
-
-
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
40
-
-
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required.
40
-
-
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
-
-
-
3.5 C x 50 sq.mm Al
60
-
-
Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.
-
-
-
Ceiling surface indoor type Round LED Luminaire with 18 watt LED Lamp Similar to JAQUAR Cat No. LNRO02R018SC or equivalent.
10
-
-
Indoor type surface mounted TUBE LED Luminaire with LED Lamp Similar to JAQUAR Cat No. LGLZPCX010XC or equivalent.
2
-
-
Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.
4
-
-
Supply, Installation, testing and commissioning of high speed wall fan of 450 mm sweep 900 rpm on partition wall/ brick wall , making good the damage complete, connection, etc as required.
4
-
-
Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.
4
-
-
Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
2
-
-
Recessed wiring to television point with cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in 20 mm dia non-metalic PVC conduit with clip in type modular television socket ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. .
2
-
-
Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deep on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
2
-
-
Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
2
-
-
Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required.
3
-
-
Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .
2
-
-
Evaluation Notes How It Works ?