Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Construction Corporation Limited - OCCL Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date2 Apr 2025
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

E-procurement Notice No.60/occl/2024-25 (on-line)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Erection, Fixing & Alignment of 2nd stage embedded parts (Bottom Seal Beam, Top Seal Beam, Side Seal, Track, Guide, trestle foundation, dogging foundation etc.) for 02 Nos. of Depletion Sluice Emergency Gates and 02 Nos. of Depletion Sluice Service Gates of size 1400mm X 2100mm each at Block No. 5 & 6 of Lower Suktel Project including all labour, tools, tackles & consumables, Industrial gas etc. as required for execution of the work & as per direction of Engineer-in-Charge .

15.22

-

-

... More
Providing RCC Concrete of grade M-25 for 2nd stage concreting of seal beam, track–guide, side & top seal grooves, Trestle foundation Blockouts for 02 nos. of Depletion Sluice Emergency Gates and 02 nos. of Depletion Sluice Service Gates of size 1400mm X 2100mm each at Block No. 5 & 6 including supply & using 20mm and 10mm downgraded crusher broken hard granite aggregates of approved grades and quality from approved quarry free from weathered skin surface, dust and any other deleterious materials as per approved design, drawing and specification with all leads, lifts, de-lifts including supply cost of all materials, supply cost of approved grade cement, sand & aggregates etc. including cost of carriage, royalty and all other taxes of all materials mixing and vibrating concrete by mechanical means including centering, shuttering, scaffolding, staging de-shuttering and supply of all T & P, machineries like Concrete Mixture, Vibrator, labour charges cost and carriage of water for mixing concrete and curing including hire and running charges of all machineries equipments constructions / erection and removal of gangway staging, scaffolding, incidental charges complete as per the direction and instruction of Engineer-in-Charge.

46.6

-

-

... More
Drilling and Chemical Grouting for 16 mm Dia Anchor Bars ( 20 mm Dia × 200 mm Depth) with supply of branded Chemical, Labours, Machineries as required to complete and finish for Fixing of Ladder, Hand Drilling in M-25 Grade Concrete as per direction of Engineer-in-Charge.

112

-

-

... More
Painting of 02 (Two) Nos. of Depletion Sluice Service Gate & 02 (Two) Nos of Depletion Sluice Emergency Gate after blast cleaning process performed with as per requirements & class 'A' of IS 14177: 1994. After blast cleaning, the surface should be cleaned from loose dust & debris by air blast with help of blower. Over the prepared surfaces, two coats of zinc rich primer (containing not less than 85% zinc rich on dry film) should be applied to give a dry film thickness of 70 ± 5 microns. First coat of primer should be applied within six hours of sand blasting. Fnishing coat should consist of 02 coats of solventless coal tar epoxy paints. These should be applied at an interval of 24 hours. Each coat should give minimum dry film thickness of 150 ± 5 microns. Total dry film thickness of all coats including primer coat should not be less than 350 microns. The rate should include compressor, painting equiments, labour, other machinery, scaffolding etc. required for painting.

360

-

-

... More
Erection, Commissioning, Testing of 02 (Two) Nos. of Depletion Sluice Service Gate, 02 (Two) Nos of Depletion Sluice Emergency Gate (Fixed wheel Vertical Lift Gates) & its components, Fitting of Gate Wheesl, Rubber Seal, Rope attachments, Trestle structures, Hoist Platforms,12 MT Capacity Hoists for Service Gates / 20 MT Capacity Hoists for Emergency Gates & Supporting Structures, Rope Drums, Central Drive Unist, Wire Rope Connections and its Dogging arrangements, Walkways, Ladders, Hand Railings etc. including all labour, tools, tackles & consumables, Industrial gas , one suitable capacity crane with operator & POL etc. as required for execution of the work at Block No. 5 & 6 of Lower Suktel Project & as per direction of Engineer-in-Charge.

63.25

-

-

... More
Painting of Trestles, Hoist Assembly, Walkways, Ladders and Hand Railings :- 02 Sets after blast cleaning process performed with as per requirements & class 'B' of IS 14177: 1994. After blast cleaning, the surface should be cleaned from loose dust & debris by air blast with help of blower. Over the prepared surfaces, two coats of zinc phosphate primer should be applied to give a dry film thickness of 40 ± 5 microns per each coat. First coat of primer should be applied within six hours of sand blasting. Fnishing coat should consist of 01 coat of alkyed based micaceous iron oxide paint at dry film thickness of 65 ± 5 followed by 02 coats of synthetic enamel paint confirming to IS 2932 : 1974 to give dry film thickness of 25 ± 5 microns per coat of synthetic enamel paint. Total dry film thickness of all coats including primer coat should not be less than 175 microns. The rate should include compressor, painting equiments, labour, other machinery, scaffolding etc. required for painting.

450

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.