National Institute Of Technology Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
National Institute Of Technology - NIT Tender
Civil And Construction
Eprocure
Opening Date28 Sep 2024
Closing Date21 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 1,00,000Document Cost
₹ 4,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NITRK_828372_1Bid Award Id
ViewTender No
NITR/EM/2024/L/0736/1281Tender Authority
National Institute Of Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
MAIN DISTRIBUTION METER PANEL (Type-3): INCOMER: MCCB, 160A, 4P, 50 KA, 415 VAC with adjustable O/L, S/C protection with suitable spreader link & Rotary Handle with aux. contact- 01 set Make: SIEMENS (VA/VL series), LEGRAND
Whole current Single phase, two wire energy meter 230/240 V (P-N), 10-60A, 50 Hz, Accuracy class 1.0 Burden Voltage circuit: 0.5W and 1 VA Current circuit: 0.1 VA : 09 nos. Make: SECURE SARAL RED, YELLOW & BLUE INDICATION LAMP 230VAC, ON OFF Indication Lamp 230 VAC
LED Lamp with necessary switch control for operation during night hours.
Outgoing: MCB, 63A,DP, 10 KA - 09 sets Make: SIEMENS / Legrand
Terminal Block 150 A for outgoing feeders connected wth 16 sqmm copper flexible wire -09 sets
Fabrication: 2/1.6 mm CRCA Steel Sheet (INDOOR TYPE)
Aluminium bus-bar of suitable size
Paint: RAIL 7035
Protection: IP65
Panel drawing will be finalized by EE, NIT depending on the compatibility of installtion on the wall.
6
-
-
Hall Area Shopping Complex Meter Panel
Incomer:
250A 4P 50KA MCCB with O/L & S/C Thermal Magnetic Release, Rotary Handle & necessary spreader link - 01 set (Make: SIEMENS VL/VA series or Legrand)
Digital MFM meter (96X96 mm),CTR-250/5, Cl-1, Aux supply-230V AC with R-Y-B and ON-OFF indicating lamp along with required SP MCB control
OUTGOING:
63A 3P 36KA MCCB (Make: SIEMENS VL/VA series or Legrand) with O/L & S/C Thermal Magnetic Release, Rotary Handle, 100 A 3 phase whole current meter (SECURE) with suitable wiring by copper wire upto the terminal blocks - 03 sets each
40A DP 10kA MCB with 60 A 1-phase KWH meter (SECURE) - 06 sets each
1
-
-
Design, fabrication, assembling, wiring & supply of Following outdoor Panels, fabricated out of 14/16 Gauge CRCA sheet steel in cubicle compartmentised modular construction complete with supporting rigid structure, interconnections, aluminium bus bar strip with heat shrinkable colour coded current density of bus bar 0.8 A per sqmm Identification on all breakers & MCCB to indicate the area they serve. Degree of protection IP 65, earthing hinged doors with 2.5 sqmm tinned braded copper wire, suitable for pedestal floor mounted with removable Gland Plates on bottom of the panel, all mounting plates shall be GI sheets. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. Galvanised hardwares with zinc passivation shall be used in fabrication of panels 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415 V, 3 Phase, 4 Wire, 50Hz supply system.
-
-
-
PDB Panel at Guest House (NB)
Incomer-1:
400A 4P 50KA MCCB with O/L & S/C Thermal Magnetic Release, MCCB AUX. CONTACTs, Rotary Handle & necessary spreader links/Aluminium BusBar - 01 set (Make: SIEMENS VL/VA series or Legrand)
Digital MFM meter (96X96 mm),CTR- 400/5A, 5VA Class: 1.0, Metering Current Transformer, Aux supply-230V AC with R-Y-B and ON-OFF indicating lamp along with required SP MCB control
Incomer-2:
250A 4P 50KA MCCB with O/L & S/C Thermal Magnetic Release, MCCB AUX. CONTACTs, Rotary Handle & necessary spreader links/Aluminium BusBar - 01 set (Make: SIEMENS VL/VA series or Legrand)
Digital MFM meter (96X96 mm),CTR- 250/5A, 5VA Class: 1.0, Metering Current Transformer, Aux supply-230V AC with R-Y-B and ON-OFF indicating lamp along with required SP MCB control
400A ONLOAD CHANGEOVER:
400A ONLOAD CHANGROVER SWITCH - 01 set Make: ABB/SOCOMEC
Digital MFM meter (96X96 mm),CTR- 400/5A, 5VA Class: 1.0, Metering Current Transformer, Aux supply-230V AC with R-Y-B indicating lamp along with required SP MCB control
OUTGOING:
200A 4P 36KA MCCB (Make: SIEMENS VL/VA series or Legrand) with O/L & S/C Thermal Magnetic Release, Rotary Handle, MCCB Aux Contact, Digital MFM meter (96X96 mm), CTR- 200/5A, 5VA Class: 1.0, Metering Current Transformer, Aux supply-230V AC with R-Y-B indicating lamp, ON/OFF lamp along with required SP MCB control - 03 sets each
100A 4P 36KA MCCB (Make: SIEMENS VL/VA series or Legrand) with O/L & S/C Thermal Magnetic Release, Rotary Handle, Aux supply-230V AC with R-Y-B indicating lamp, ON/OFF lamp along with required SP MCB control, 100 A 3 phase whole current KWH meter (SECURE) with suitable wiring by copper wire upto the terminal blocks - 01 set 63A FP 10 kA MCB: 06 sets
40A DP 10kA MCB : 06 sets
1
-
-
AMF Panel
Incomer-EB
250A 4P 50KA MCCB with O/L & S/C Thermal Magnetic Release and suitable contactors for auto opertion
MCCB Door Interlock (Rotary Handle)
MCCB Spreader Link
MCCB AUX. CONTACT
250A 4P POWER CONTACTOR AUX. CONTACTOR 2N0+2NC-COIL-230VAC
ONDELAY TIMER-230VAC Digital MFM meter (96X96 mm),CTR-250/5, Cl-1, Aux supply-230V AC
250/5A, 5VA Class: 1.0, Metering Current Transformer
Red Indicating Lamp, 230V AC
Yellow Indicating Lamp, 230V AC
Blue Indicating Lamp, 230V AC
Red Indicating Lamp, 230V AC-ON
GREEN Indicating Lamp, 230V AC-OFF
START PUSH BUTTOM WITH NO ELEMENT
STOP PUSH BUTTOM WITH NO ELEMENT
6A 10KA C-CURVE SP MCB 10A 10KA C-CURVE DP MCB Incomer-2-63KVA DG
250A 4P 50KA MCCB with O/L & S/C Thermal Magnetic Release and suitable contactors for auto opertion
MCCB Door Interlock (Rotary Handle)
MCCB Spreader Link
MCCB AUX. CONTACT
250A 4P POWER CONTACTOR AUX. CONTACTOR 2N0+2NC-COIL-230VAC
AUX. CONTACTOR 2N0+2NC-COIL-24VDC
AUX. RELAY 2N0+2NC-COIL-24VDC
AUX. RELAY 2N0+2NC-COIL-230VAC
ONDELAY TIMER-230VAC
AMF RELAY
12V-10A BATTERY CHARGER
AUTO/MANUAL SWITCH Digital MFM meter (96X96 mm),CTR-250/5, Cl-1, Aux supply-230V AC
250/5A, 5VA Class: 1.0, Metering Current Transformer
Red Indicating Lamp, 230V AC
Yellow Indicating Lamp, 230V AC
Blue Indicating Lamp, 230V AC
Red Indicating Lamp, 230V AC-ON
GREEN Indicating Lamp, 230V AC-OFF
START PUSH BUTTOM WITH NO ELEMENT
STOP PUSH BUTTOM WITH NO ELEMENT
6A 10KA C-CURVE SP MCB 10A 10KA C-CURVE DP MCB 10A 10KA C-CURVE DP MCB OUTGOING 100A MCCB 100A FP 36KA MCCB with O/L & S/C Thermal Magnetic Release – 02 sets
MCCB Door Interlock (Rotary Handle)
MCCB Spreader Link
MCCB AUX. CONTACT Digital MFM meter (96X96 mm),CTR-100/5, Cl-1, Aux supply-230V AC
100/5A, 5VA Class: 1.0, Metering Current Transformer
Red Indicating Lamp, 230V AC-ON
GREEN Indicating Lamp, 230V AC-OFF
6A 10KA C-CURVE SP MCB OUTGOING 40A DP MCB 63A FP 10KA MCB -06 sets
40A DP 10KA MCB -06 sets
1
-
-
For detailed specification, please refer the Annexure TS of main tender document.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements