National Institute Of Science Education And Research Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

National Institute Of Science Education And Research - NISER Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Dec 2023
Closing Date9 Jan 2024
Tender Amount₹ 51,92,681 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, and supports etc. as per approved specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006. 0.63 mm

260

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, and supports etc. as per approved specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006. 0.80 mm

90

-

-

... More
Supplying and fixing of 25 mm thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (Class 'O') insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation complete as per specifications as required.

350

-

-

... More
Providing plumbing work for drainage requirements i/c supply of CPVC pipe, fittings such as bends, reducer, elbows, tees, unions, flanges, including insulation of piping with 6 mm thick nitrile Insulation sleeve etc. as Required. Preferred make – Astral, Supreme or Oriplast

90

-

-

... More
Supplying & fixing of powder coated extruded aluminium supply air grills with aluminium volume control dampers as per specifications.

6

-

-

... More
Supplying & fixing of powder coated extruded aluminium supply air grills with louvers but without volume control dampers as per specifications.

8

-

-

... More
Supplying & fixing testing commissioning of supply diffusers of powder coated aluminium with aluminium volume control dampers with anti-smudge ring & removable core

4

-

-

... More
Supplying & fixing testing commissioning of return air diffusers of powder coated aluminium without volume control dampers with anti-smudge ring & removable core.

5

-

-

... More
Heating kit/ Dehumidifier comprising strip heaters, thermostat, humidistat, safety thermostat. The minimum capacity of heaters shall be as indicated below. The heaters should be arranged in independently operating banks, in the main Return air at suitable location and the controls shall be housed in a separate factory fabricated box and complete as required. Heater capacity should cater for all seasonal variations and changes in equipment/product load from 0% to 100%. Heater bank shall be operated through Humidistat and thermostat. Heaters shall be connected in equal capacity across each phase as per following. Preferred make - GEC or equivalent. 6 KW Strip Heater for De Humidification

2

-

-

... More
Supply, installation, testing and commissioning of growth room of 80 mm PUF panel with cam-lock joint with one side 0.5 mm PPGI sheet and other side 0.5 mm SS 304 sheet. PUF density: 40 +or- 2 kg/m3. Two Growth Room size: 12ftX15ftX9ft. Counter entry corridor size: 24ftX3ftX9ft. Flooring with 80 mm PUF panel with 1.2 mm anti-skid GI sheet. Provision of 5 nos hinged door of 750mmX2000mmX80mm with door view glass. Condensing and Evaporating units (Preferred make - RINAC or equivalent) of 5 KW capacity to maintain 2 to 8 Deg. C with hermetic compressor including Copper piping, insulation with nitrile rubber insulation and accessories as required including temperature controller (preferred make - Dixell or equivalent), expansion valve, charging of eco-friendly refrigerant (R-404A/ R-407C/ equivalent), Drain piping as required, electrical control panel, 4 nos. light for each room and corridor as required with separate control switch with following detailed specification - Power input 653.0 W, Spectrum Range 380-780nm at 2 meter growth height R : FR ratio minimum, 13.0 (Sellaro et al. 2010), 13.7 (Smith 1982) 14.0 (600-699/700-799 nm). Light output (380 - 780nm). 1691.27μmol/s Target Average Intensity 300.0 μmol/m2/s Calculated Average Intensity 282.38 μmol/m2/s Light Loss 23.67% Area within target intensity range (200.0 - 400.0 μmol/m2/s) [Yellow] 98.0 %Area below target intensity ( 200.0 μmol/m2/s) [Blue] 1.0 % Area exceeding target intensity ( 400.0 μmol/m2/s) [Red] 0.0 %, Heat Produced 77981.26 BTUs / 82270.23 kJ. Wiring with appropriate size of wire including Sub-panel to control panel and all accessories as required to complete as instructed by EIC

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.