Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date28 Dec 2024
Closing Soon18 Jan 2025
Tender Amount₹ 31,00,000 
Notes
Download

Costs

Summary

Repair Replacement Of Old Unsv Lt Cable Ab Cable Feeder Pillar Dbs Mccb Changeover Lt Panel Earthing And Other Allied Works At Rx And Otm Accn Shankarpur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified and directed. Note- Punned thickness will be measured at the time of measurement and payment.

12.15

-

-

... More
S&F bricks fly ash bricks locally available best quality laid in trenches over sand cushioning for cable protection complete all as specified and directed.

1300

-

-

... More
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.

0.22

-

-

... More
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) kerbs etc including necessary formwork, concrete exposed surface shall be finished even and fair without using extra cement complete all as specified and directed.

2.04

-

-

... More
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping above ground levels including necessary formwork, concrete exposed surface shall be finished even and fair without using extra cement complete all as specified and directed.

0.41

-

-

... More
Material and labour for XLPE insulated, steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq mm 3.5 core including taking down old U/S cable complete all as specified and directed.

100

-

-

... More
Material and labour for fixing XLPE insulated, steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq mm 3.5 core including taking down old U/S cable complete all as specified and directed.

120

-

-

... More
Material and labour for fixing XLPE insulated, steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.

100

-

-

... More
Material and labour for fixing XLPE insulated, steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq mm 3.5 core, including taking down old UNSV cable complete all as specified and directed.

150

-

-

... More
Material and labour for fixing XLPE insulated, steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq mm 3.5 core,including taking down old UNSV cable complete all as specified and directed.

150

-

-

... More
S&F in replacement 200 W LED flood light/highmast light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangement complete all as specified and directed. (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate). (Make:Havells/Crompton / Bajaj / Philips.)

6

-

-

... More
S&F in replacement 300 W LED flood light/highmast light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangement complete all as specified and directed. (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate). (Make:Havells/ Crompton / Bajaj / Philips.)

3

-

-

... More
S&F 200 W LED highbay light fitting energy efficient light distribution efficacy upto 150lm/watt including all necessary clamps, nuts , bolts or fixing arrangement at hangar and taking down old UNSV complete all as specified and directed. ( (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate).Make:Havells/Crompton / Bajaj / Philips.)

18

-

-

... More
S&F 180 W LED highbay light fitting energy efficient light distribution efficacy upto 150lm/watt including all necessary clamps, nuts , bolts or fixing arrangement and taking down old UNSV complete all as specified and directed. (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate). (Make:Havells/Crompton / Bajaj / Philips.)

10

-

-

... More
Supply and fix cable jointing kit 1.1 KV grade, straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 sqmm,Indoor/Outdoor type complete all as specified and directed.

1

-

-

... More
Supply and fix cable jointing kit 1.1 KV grade, straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 sqmm,Indoor/Outdoor type complete all as specified and directed.

2

-

-

... More
Supply and fix cable jointing kit 1.1 KV grade, straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 sqmm,Indoor/Outdoor type complete all as specified and directed.

2

-

-

... More
Supply and fix cable jointing kit 1.1 KV grade, straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm,Indoor/Outdoor type complete all as specified and directed.

1

-

-

... More
S&F 80 mm bore galvanised iron pipes, 'light grade' with all fittings and accessories laid in trenches or fixed to wall / pole including taking down old UNSV complete all as specified and directed.

40

-

-

... More
Supply & fixing testing and commissioning CPRI approved vermin/weather proof LT panel board canopy indoor type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out minimum 2.0 mm thick CRCA sheet powder coated, CPRI Approved, mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars of 900 Amps rating - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs/MCBs, cable glands of suitable sizes for incoming and outgoing cables , including necessary locking arrangement complete all as specified and directed including the necessary PCC work and with and including following :- Note: (i) Contractor will submit drawing for approval, (ii) Cost included dismanteling of old unserviceable panle/busbar chamber including necessary terminmation/jointing in the replaced panel in complete):- Main Incoming : 630 Amp, 4 pole On line Changeover Switch-01 No MCCB 630 Amp, 50 KA, 4 Pole - 01 No (Incomer) Main Outgoing:- (a) MCCB 200 Amp, 36 KA, 4 Pole - 04 Nos (b) MCCB 125 Amp, 25 KA, 4 Pole - 01 Nos (c) MCCB 200 Amp, 36 KA, 4 Pole - 01 Nos (Spare) (d) Digital Ammeter with CTs & Selector switches - 01 No (e) Digital Voltmeter -01 No & Multifunction meter - 01 No (f) RYB phase indicator. Note : (a) PCC foundation & excavation will be measured and paid separately.

1

-

-

... More
Supply & fixing testing and commissioning CPRI approved vermin/weather proof LT panel board canopy indoor type type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out minimum 2.0 mm thick CRCA sheet powder coated, CPRI approved mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars of 200 Amps rating - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs/MCBs, cable glands of suitable sizes for incoming and outgoing cables , including necessary locking arrangement complete all as specified and directed including the necessary PCC work and with and including following :- (Note: (i) Contractor will submit drawing for approval, (ii) Cost included dismanteling of old unserviceable panle/busbar chamber including necessary terminmation/jointing in the replaced panel in complete):- (a) MCCB 4 pole 125 amps of 25 KA (Incomer) - 01 Nos (b) MCB FP 63 amps 10KA (Outgoing) - 03 Nos (c) MCB FP 32 amps 10 KA (Outgoing) - 07 Nos (d) LED Indicator lamp set of 3 (e) Ampere meter digital type - 01 No (f) Voltmeter digital type with CTs - 01 No Note : (a) PCC foundation & excavation will be measured and paid separately.

2

-

-

... More
Supply & fixing testing and commissioning CPRI approved vermin/weather proof LT panel board canopy indoor type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out minimum 2.0 mm thick CRCA sheet powder coated, CPRI approved mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars of 480 Amps rating - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs, cable glands of suitable sizes for incoming and outgoing cables , including necessary locking arrangement complete all as specified and directed including the necessary PCC work and with and including following (Note: (i) Contractor will submit drawing for approval, (ii) Cost included dismanteling of old unserviceable panle/busbar chamber including necessary terminmation/jointing in the replaced panel in complete):- (a) 250 Amp 4 pole On line Changeover Switch - 01 No (b) MCCB 4 pole 250 amps of 35KA (Incomer) - 01 No (c) MCCB 4Pole 100 amps 25KA (Outgoing) - 03 Nos (d) MCCB 4Pole 63 amps 25 KA (Outgoing) - 01 No (e) LED Indicator lamp set of three (f) Ampere meter digital type -01 (g) Voltmeter digital type with CTs - 01 (h) Multifunction meter -01 (j) MCCB 4Pole 100 amps 25KA (Outgoing) - 01 No(spare) Note : (a) PCC foundation & excavation will be measured and paid separately.

1

-

-

... More
Supply & fixing testing and commissioning CPRI approved vermin/weather proof LT panel board canopy indoor type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out minimum 2.0 mm thick CRCA sheet powder coated, CPRI approved mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars of 480 Amps rating - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs, cable glands of suitable sizes for incoming and outgoing cables , including necessary locking arrangement complete all as specified and directed including the necessary PCC work and with and including following (Note: (i) Contractor will submit drawing for approval, (ii) Cost included dismanteling of old unserviceable panle/busbar chamber including necessary terminmation/jointing in the replaced panel in complete):- (a) 250 Amp 4 Pole On line Changeover Switch -01 No (b) MCCB 4 pole 250 amps of 35KA (Incomer) - 01 No (c) MCCB 4Pole 100 amps 25KA (Outgoing) - 01 No (d) MCCB 4Pole 63 amps 25 KA (Outgoing) - 02 No (e) LED Indicator lamp set of three - 01 No (f) Ampere meter digital type -01 No (g) Voltmeter digital type with CTs - 01 (h) Multifunction meter -01 (j) MCCB 4Pole 100 amps 25KA (Outgoing) - 01 No(spare) Note : (a) PCC foundation & excavation will be measured and paid separately.

1

-

-

... More
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed.

10

-

-

... More
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.

80

-

-

... More
Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers shall be deemed to included in quoted rate. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor.

200

-

-

... More
Labour for Maintenance and attending breakdown complaints of LT panels/SFUs/ Changeover/ Isolator/ Busbar panels/Fuse units/starter/MCCBs/TPN DBs other electrical connectings units alongwith checking/ finding of faults of connected over head lines and under ground LT cables complete circuit from LT connection at terminals of transformer to ACBs/MCCBs of LT panels of sub-stations/feeder pillar box and upto main distribution boards at buildings/OTM, including attending minor repairs/mainetnance of LT panels for smooth and trouble free LT power supply , rectification of minor defects to electrical controls and accessories and attending breakdowns at any time around the clock all as sepcified and directed. Note:- (a) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering or other testing as required for any fault identification and securing/reconnecting cables or connected switch gear after defect rectification is deemed to be included in the scope. (b) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/ torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor.

200

-

-

... More
Supply and fix cable jointing kit, 1.1 KV grade, outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Al conductor cable of size 300 sqmm complete all as specified and directed.

1

-

-

... More
Supply and fix cable jointing kit, 1.1 KV grade, outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Al conductor cable of size 120 to 150 sqmm complete all as specified and directed.

2

-

-

... More
M&L for vegetation/wild grass/bushes clearance in E/M installation area, around feeder pillar boxes, along the UG cables, street light/LT poles for prventive maintenance/break down attendance complete all as specified and directed. Note: (a) The contractor should provide sufficient manpower and machinery as required for immediate preventive/ breakdown services. (b) The contractor should provide all safety gears like helmet, gum boots/ apron etc and safety of the workmen will be responsibility of contractor.

3000

-

-

... More
S&F, PVC insulated 4 core 2.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed.

200

-

-

... More
Supply and fixing in replacement 400 Amp MCCB 4pole, 36 kA breaking capacity Adjustable Thermal & Fixed Magnetic complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement pointed Air termination, five pointed , copper rod 12 mm dia and 300 mm long fixing with two nos nuts and washers complete all as specified and directed.

60

-

-

... More
Supply and fixing in replacement Copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed

800

-

-

... More
Supply and fixing in replacement 25x3.15 mm aluminium strip including PVC saddle as per sample approved complete all as specified and directed.

500

-

-

... More
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75 mm x 75mm x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screen complete all as specified and directed.

10

-

-

... More
Material & Labour for GI Pipe light grade of 40mm (ISI mark) to cover complete all as specified and directed.

40

-

-

... More
M&L for Polymer insulators for fixing of earthing strip complete all as specified and directed.

620

-

-

... More
M&L earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of copper strip 20x3.15mm by means of copper bolts, nuts, check nuts and washers/brazing welding of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.