Mahanadi Coalfields Limited Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Mahanadi Coalfields Limited - MCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date29 Jan 2025
Closing Date10 Feb 2025
Tender Amount₹ 39,88,943 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

17.6

6777

119283.12

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

8.71

8037

70005.32

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto15degree, landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral staircases upto floor five level excluding the cost of centering, shuttering, finishing & reinforcement with 1:1.5:3(1cement:1.5coarse sand:3 grded stoneaggregate 20mm nominal size).

33.77

8394

283478.89

... More
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size).

0.4

7811

3124.72

... More
Centering and shuttering including strutting, propping etc.and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete

37

252

9344.35

... More
Centering and shuttering including strutting, propping etc.and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts

84

649

54595.8

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers

137

505

69287.75

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform

156.31

619

96787.15

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges

29.82

918

27382.22

... More
Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars

2110

97

206569

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars

4198.8

97

411062.52

... More
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

25.06

4897

122736.36

... More
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

44.7

6059

270870.83

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

45.2

118

5340.38

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

285

174

49746.75

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)

524.3

217

114009.03

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

177

196

34842.45

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

4.2

4287

18006.66

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

78

559

43676.1

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

107

645

69116.65

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

206.05

99

20553.49

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

1.44

977

1407.67

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions ol engineer-in-charge . (Cost of aluminium snap beading shallbe paid in basic item):with float glass panes of 5 mm thickness {weight not less than 12.50 kg/sqm)

14.74

1323

19512.81

... More
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

14

193

2713.9

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Anodized (AC 15 ) aluminium tubular handle bar

4

739

2958.4

... More
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.

1

1096

1096.15

... More
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm

2

331

663.1

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm

4

118

475.8

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm

4

67

270

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

4

88

352.8

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm

139

1213

168641.75

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

14

1261

17664.5

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer

371

141

52496.5

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm)

282

147

41538.6

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

15

362

5442.75

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend

4

184

738.8

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe

4

146

585.6

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm

16

279

4466.4

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

30

526

15808.5

... More
Lettering with black Japan paint of approved brand and manufacture

825

4

3423.75

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

21.1

173

3665.07

... More
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

10.08

51

521.14

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work

32

110

3521.6

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Medium shade pigment using 50% white cement 50% Grey cement

477.3

988

471954.24

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Bulb/Call bell point

10

897

8970

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.light point/ fan point/ exhaust fan point/out door light point

18

1135

20430

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.light point/ fan point/ exhaust fan point/out door light point

21

1365

28665

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

22

140

3080

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

22

164

3608

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mm X 75mm)

11

340

3740

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door.

2

2351

4702

... More
suppling fixing 5 AMPS to 32 AMPS rating,240 volts, "c" series, MCB suitablb for inductive load offollowing poles in the existing MXCBV DB complite with connections,testing and comissioning etc.As required.

16

247

3952

... More
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRCfuses,connections, earthing etc. as required.100 Amps

1

14439

14439

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single corecable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

80

266

21280

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single corecable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4sq. mm earth wire

78

324

25272

... More
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FR PVC insulated copper conductor, single corecable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

20

392

7840

... More
Installation,testing & comimissiong of pre- wired, fluorescent fitting/compact fluorescent fittingof all type ,complete with all accessories and tube etc.Directly on ceilling/wall, incloduing connection with 1.5 sqmm FRLS PVC insulated,copper conductor,single core cable and earthing etc.AS required.

15

149

2235

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc.as required.

14

156

2184

... More
Earthing with G.I earth pipe 4.5 mtrs long,40 mm dia including accessories ,providing masonry enclosure with cover plate having looking arrangment and watering pipe etc.with charcoal and saltas required

2

6471

12942

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

30

215

6450

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

14

321

4494

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

2

3100

6200

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required but excluding sand cushioning, protective covering. Upto 35 sqmm.

30

131

3930

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

45

69

3105

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

4

98

392

... More
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hall tosuit the size of the above fan,making good thedamage ,connection,testing,commissioning etc.AS required.

2

334

668

... More
Supply and fixing of 90 watt IP- 66 , input voltage 90 to 300 volt at 50 HZ ,type 3 LED module as per IS:16107(part -2/sec-1/2012 metalic body Street light with bracket..PHILIPS/BAJAJ make or equivalent.

7

3967

27769

... More
Supply of 1200mm sweep Ceiling Fan 220 volt Isi mark.orient or equivalent.

14

1975

27650

... More
Supply of 20 watt,LED batten 220v ISI marked.

15

163

2445

... More
Supply and Fixing of 60 watt well glass fixture LED down lighting.IP- 66 , input voltage 90 to 300 volt at 50 HZ ,type 3 LED module as per IS:16107(part -2/sec-1/2012 metalic body with bracket.

9

4013

36117

... More
Supply of 16 sqmm 3.5 core armoured Aluminium cable.1.1 KV PVC insulated and PVC Shelted AyFy TYPE.

50

215

10750

... More
Supply of 450 mm Exhausted Fan 220 volt ISI mark. BAJAJ make or equivalent

2

5651

11302

... More
Supply and Fixing of 15 watt Self ballast LED bulb.

4

197

788

... More
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC

1

33520

33520.53



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.