Mahanadi Coalfields Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Mahanadi Coalfields Limited - MCL Tender

Civil And Construction
Building Construction
Eprocure
Opening Date1 Apr 2023
Closing DateCancelled
Tender Amount₹ 2,86,85,231 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Heat sink should be die-cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes Junction temperature 85 degC Operating temperature range -10 deg C to +55 deg C The luminaire shall be protected against surges and transients ( Internal) /=5KV The luminaire shall be protected against surges and transients of /=10KV (External) Number of electronic control gear (power supplies) 4 Nos.Length of ISI marked three core wire (shall be provided along with supply of material) 100 cm (Smart LED Spot lights for highlighting the Statue and trees shall be approved by Engineer-in-charge).

-

-

-

... More
Construction of water fountain works for lawns and pond area-Finish of Water Body Tiles Height of Water Body (Meter) NADia of Water Body (Meter) 3Shape of Water Body Round,Pump, Plumbing & Nozzles-Stainless Steel,Type of Pump For Water Body -Submersible,Material of Plumbing-CPVC,Number of Bubbler Nozzle 6,Decorative Lights Number of Programmable Water Proof Lights 20 Watt To 30 Watt 6 Casing of Submersible Lights Stainless Steel Number of Programmable Water Proof Lights 5 Watt To 10 Watt 6 Rotation Angle of Lights 120 Degree

3

-

411016.95

... More
Protection IP 67 Number of Programmable Water Proof Lights 10 Watt To 20 Watt 4 Number of Programmable Water Proof Lights 30 Watt To 60 Watt 6,Electrical-Depth of Boring (3/4 Inch) With Suitable Pump & Copper Cable 500 ,Lt Cable (10 Sqmm 4 Core)Type of Earthing Plate Earthing,Copper Wiring 4Electric Panel 32 AmpTPN (Water fountain for highlighting the Statue and trees shall be approved by Engineer-in-charge).

-

-

-

... More
New Statue Erection work, HEAVY DUTY STATUE OUTDOOR for CMD Bangalow and Director Bangalow (new statue eraction shall be approved by Engineer-in-charge).

7

-

51271.19

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

56.89

-

977.8

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- charge.

18.66

-

1687.7

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead

13

-

270.4

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm

115.87

-

62.8

... More
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : Asbestos Cement sheet

31.13

-

40.05

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.

374.65

-

135.25

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

122.7

-

182.4

... More
Supplying and filling in plinth with river sand under floors, including watering, ramming, consolidating and dressing complete.

173.5

-

978.25

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 fine sand : 6 graded stone aggregate 40 mm nominal size).

36.06

-

4677.2

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

90.05

-

147.2

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

217.27

-

1549.15

... More
Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

131.55

-

7045.6

... More
Centering and shuttering including strutting, propping etc. Foundations, footings, bases of columns, etc. for mass concrete

120.99

-

226.65

... More
Centering and shuttering including strutting, propping etc. Lintels, beams, plinth beams, girders, bressumers and cantilevers

300.04

-

438.1

... More
Centering and shuttering including strutting, propping etc. Suspended floors, roofs, landings, balconies and access platform

242.41

-

534.3

... More
Centering and shuttering including strutting, propping etc. Columns, Pillars, Piers, Abutments, Posts and Struts

601.37

-

582.8

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level :TheMetreo-Mechanically Treated bars of grade Fe-500D or more.

13154.57

-

81.65

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

113.35

-

2403.3

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality confoMetreing to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.,complete.

26.91

-

908.4

... More
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of SOMANY or other approved makeapproved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.(300x600mm wall tiles)

103.19

-

1268.2

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

25.56

-

1485.55

... More
Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).

89.16

-

268.3

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

49.13

-

5608.95

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (Brick work shall be approved by Engineer-in-charge).

147.37

-

4509.4

... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

265.92

-

256.9

... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster

1116.86

-

337.15

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade::New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1382.78

-

138.45

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll foMetreing process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and

0.45

-

5790.15

... More
drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm 9.147C both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

-

-

-

... More
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats.

7.88

-

1624.9

... More
The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-incharge. (For W.C. and bathroom door shutter).

-

-

-

... More
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with"S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.

5

-

2626.9

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern

3

-

4933.8

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

4

-

3408.15

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

10.15

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete.

2

-

1246.05

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type : with sewer bricks conforming to IS:4885

5

-

1881.7

... More
Providing and fixing 15 mm C.P. brass tap with elbow operation lever

5

-

1265

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality - L.D. - 2.5 : Rectangular shape 600x450 mm internal dimensions

7

-

1156.45

... More
Providing S.C.I. gully or nahani grating 100 mm dia

7

-

24.49

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having theMetreal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the direction of E-I-C. 20 mm nominal dia pipes

25

-

433.1

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having theMetreal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the direction of E-I-C. 25 mm nominal dia pipes

15

-

545.65

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having theMetreal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the direction of E-I-C. 32 mm nominal dia pipes

35

-

727.8

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

589.85

-

584.7

... More
Supply and Fixing of Tensile structure for size 5.0 mtr X 6.0 Mtr. The structure shall be designed in accordance with I.S 800 with the designed wind speed as defined by IS: 875 based on location site conditions and load combinations as defined IS: 875, The membrane should be minimum 702 GSM Ferrari Fabric The above mentioned fabric will be patented and welded with the high welding machine for 30mm wide and at the end pockets will be made to slide the kedar profile and will be fixed using special aluminium extrusions at the end of the roof truss.

1086.29

-

211.86

... More
The fabric joints, cable saddles, mast tops and bases, and tensioning mechanisms and all relative necessary hardware and labour and transport The complete structure will be designed for wind load and live load. This also includes two coat epoxy primer and paint. The Shop drawings including frame structure of stainless steel structure and fabric with all the necessity structural design to be submit before installetion. The work includes 3 No of Stone Benches and area development as per drawing and instruction from Engineer.

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

50

-

594.33

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

10

-

854

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

100

-

187

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

100

-

187

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 180 mm X 150 mm X 60 mm deep

25

-

138

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).

25

-

224

... More
Supplying and fixing 5 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

10

-

862

... More
Supply and fixing for seating Bench,Cast iron garden bench (FRP STRIP) (PF 908) capacity 3 adults (area1.52mtr x 0.61mtr) height 0.45 mtr., complete all complete as per the direction of Engineer-in-charge.

15

-

10169.49

... More
Brick work with fly ash brick (230x115x75 mm size) bricks of class designation 10 in super structure above plinth level up to floor V level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand).

14.59

-

5502.4

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

508.46

-

93.8

... More
Supply and fixing for Illuminated Water Outdoor Fountain for landscape area- specification of Static Fountain,SS Nozle,Number of Programmable 6, Square Shape of Water Body,1 Number of Umbrella Nozzle,GI Material of Pipe,Submersible Pump For Water,Abs Plastic Casing of Submersible Lights,3 Number of Programmable Water Proof Lights 5 Watt To 10 Watt Body,120 Rotation Angle of Lights,IP 67 Protection,Plate Earthing,2.5 Copper Wiring,32 Amp TPN Electric Panel (Illuminated water outdoor fountain shall be approved by Engineer-in-charge).

1

-

318240.68

... More
Supplying & fitting Fixing of F.R.P "Relif" of avg. size made of Resin, Accelerator, atalyst, Glass fiber mat/ Powder etc. including cost, conveyance, royalties of all materials, all labour cost, sundries T&P complete in all respect as per specification & selected image etc.complete as per direction of the E.I.C (Painting & Mural works shall be approved by Engineer-in-charge). Water Tank & Mandapam beautification (Painting & Mural works)

820

-

850

... More
Renovating lawns including weeding, cheeling the grass,forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass foMetres a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately).

901.41

-

23.35

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

1448.5

-

671

... More
Supply and fixing for LED Bollard Light 15Watt, Total HaMetreonics Distortion Automatic Lower / Higher Cut 0 voltage 120 / 300 volt Respectively. Rated voltage 230 V AC 50 Hz Driver Eciency (in %age) Upto 100W: /=85% Input operating Voltage range and frequency AC Power Factor at full load Constructional 90 to 300 Volts AC at 50 Hz+/-2 /=0.95, Mounting Fixture size (430mm x 340mm)+/-10mm, Light Source SMD LED Chip as per LM 80/IS16106 (LED PT Module 0.5 to 1 Watt). Thickness and Ik rating Diuse 3mm, IK-08, Mounting Pipe size 60 millimeter (LED Bollard Light shall be approved by Engineer-in-charge).

30

-

6720.34

... More
Supply and fixing for kids play equipments Play Equipments (Sea Saw, Sliding, Swing) for park development area site- Garden Swing with seat and roof 3 - seater Fun PlaySeat (with integrated backrest) made up of: Fibre Reinforced Plastic Seat thickness (FRP) : 3 mmRoof made up of : Fibre reinforced plastic Roof thickness (FRP) : 2 mm Roof supported by : 20 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest at thetop,Seat (with integrated backrest) made up of Seat thickness (FRP)3 mmFibre Reinforced Plastic Roof made up of Fibre reinforced plastic Roof thickness (FRP) 2 mm Roof supported by 20 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest at thetop Whole assembly of roof supported by (4-Legs) 40 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest on both sides Height of roof (in centre) 2550 mm Width of seat 1400 mmTotal width of swing 1870 mm Seat height from ground 450 mm Leg pipe length 2950 mm,Chain length (attachedwith backrest) Chain length (attached with seat) 1250 mm 1600 mm (Play Equipments (Sea Saw, Sliding, Swing) shall be approved by Engineer-in-charge) Garden Swing with seat and roof 3 - seater

2

-

16949.15

... More
Supply and fixing for kids play equipments Play Equipments (Sea Saw, Sliding, Swing) for park development area site- Garden Swing with seat and roof 3 - seater Fun PlaySeat (with integrated backrest) made up of: Fibre Reinforced Plastic Seat thickness (FRP) : 3 mmRoof made up of : Fibre reinforced plastic Roof thickness (FRP) : 2 mm Roof supported by : 20 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest at thetop,Seat (with integrated backrest) made up of Seat thickness (FRP)3 mmFibre Reinforced Plastic Roof made up of Fibre reinforced plastic Roof thickness (FRP) 2 mm Roof supported by 20 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest at thetop

2

-

39313.56

... More
Whole assembly of roof supported by (4-Legs) 40 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest on both sides Height of roof (in centre) 2550 mm Width of seat 1400 mmTotal width of swing 1870 mm Seat height from ground 450 mm Leg pipe length 2950 mm,Chain length (attachedwith backrest) Chain length (attached with seat) 1250 mm 1600 mm (Play Equipments (Sea Saw, Sliding, Swing) shall be approved by Engineer-in-charge) Jungle Rumble Play Zone

-

-

-

... More
Supply and fixing for kids play equipments Play Equipments (Sea Saw, Sliding, Swing) for park development area site- Garden Swing with seat and roof 3 - seater Fun PlaySeat (with integrated backrest) made up of: Fibre Reinforced Plastic Seat thickness (FRP) : 3 mmRoof made up of : Fibre reinforced plastic Roof thickness (FRP) : 2 mm Roof supported by : 20 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest at thetop,Seat (with integrated backrest) made up of Seat thickness (FRP)3 mmFibre Reinforced Plastic Roof made up of Fibre reinforced plastic Roof thickness (FRP) 2 mm Roof supported by 20 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest at thetop

2

-

16949.15

... More
Whole assembly of roof supported by (4-Legs) 40 NB medium steel galvanized pipe confoMetreing to IS 1239 (part 1)/latest on both sides Height of roof (in centre) 2550 mm Width of seat 1400 mmTotal width of swing 1870 mm Seat height from ground 450 mm Leg pipe length 2950 mm,Chain length (attachedwith backrest) Chain length (attached with seat) 1250 mm 1600 mm (Play Equipments (Sea Saw, Sliding, Swing) shall be approved by Engineer-in-charge) Blow moulding Indoor Fun See Saw

-

-

-

... More
Supply and installation for RO Plant with Genset & Trolley ' covers all components complete as per governing Warranty on spare parts 6 month Warranty on whole items , supplied 1 year cope of supply includes installation, safety and operation checks of the equipment by the supplier before handover,Copies of reports and certications to be furnished to buyer on demand at time of supplies,(RO Plant installation shall be approved by Engineer-in-charge).

1

-

847457.63

... More
Supply and laying of one number PVC insulated and PVC shealthed / XLPE (heavy duty), 1.1KV grade, 10 sq mm single wire 4 core aMetreoured cable, aluminium conductor and number of core four cores power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.

700

-

286

... More
Part B Streetscaping

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil

29.97

-

135.25

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).

6.94

-

5582.1

... More
Supplying and fixing for LED Light Fixture Material – Fiber (F.R.P.) with some MS Support of approximate Dimensions In Feet Height 10’ / Width 4’ / Depth 0.98’ without bulb and cable

37

-

7786

... More
Supply and laying of one number PVC insulated and PVC Sheathed / XLPE (Heavy duty) 1.1KV grade, sq mm single wire armoured cable, Aluminium conductor and number of core four cores power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.. as required.

700

-

286

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep including conductor on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.

37

-

122

... More
Supply and drawing following sizes of FRC PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (2x1.5 sq.mm)

185

-

38

... More
Supplying and fixing following way, single pole and neutral sheet steel, MCB Distribution board, 240 volts on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, power painted including earthing etc. (2+4 way/ 6 way double door) as required. (But without MCB/ RCCB/ Isolator)

1

-

936

... More
Supply and fixing 32 amps rating, 240/415 volts, 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (32 amp, Double pole)

1

-

571

... More
Supply and fixing for seating Bench, Cast iron garden bench (FRP STRIP) (PF 908) capacity 3 adults (area 1.52mtr x 0.61mtr) height 0.45 mtr., complete all complete as per the direction of Engineer-in-charge.

25

-

10169.49

... More
Supply and installation of 14 Watt LED bulb

74

-

306.25

... More
Part C Signage

-

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-1 - 1.2mx1.5mx10mm, including tubes, name plate etc. Total weight of the signage=48.13kg

48.13

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-2 - 0.6mX0.6mx10mm, Hollow square Section - 1.5m Height (2Nos)- Total weight - 9.86+9.86+5.83kg

25.55

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Overhead Signboard Type-3 - 2.0mX1.2mx15mm, 2.5mX1.5mx15mm, 1.5mX1.5mx15mm, Name plate Hollow square Section- 3m (2nos), 2.5m (2nos), 4m (2nos) - Total weight (332+187kg)

519

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-4 - 1.2mx1.2mx10mm, including tubes, name plate etc. Total weight of the signage= 40.10kg

40.1

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-5 - 0.9mx0.9mx10mm, including tubes, name plate (2m height) etc. Total weight of the signage= 15.7+15kg

30.7

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-6 - 1.3mx1.75mx10mm, including tubes, name plate etc. Total weight of the signage= 58.15kg

58.15

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-7 - 1.3mx1.75mx10mm, including tubes, name plate etc. Total weight of the signage= 58.15kg

58.15

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-9 - 0.9mx0.9mx10mm, including tubes, name plate (2m height-2Nos) etc. Total weight of the signage= 15.7+30kg

45.7

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-10 - 1.0mx1.0mx10mm, including tubes, name plate etc. Total weight of the signage= 33.10kg

33.1

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. InfoMetreation Signboard Type-11 - 3.5mx1.5mx10mm, including tubes, name plate etc. Total weight of the signage= 400+54kg

454

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-12 - 300mmx300mmx10mm, 1.5m height L section (1no). Total weight of the signage= 23.10kg

23.1

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-13 - 0.9mx0.9mx10mm (2nos), including Squre Tube size of (2m height-2Nos) etc. Total weight of the signage= 35.7+30kg

65.7

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-14 - 2.0mx1.5mx10mm (1no), including Squre Tube size of (3m height-2Nos) etc. Total weight of the signage= 57.7+40kg

97.7

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-15 - 1.2mx1.5mx10mm, including tubes, name plate etc. Total weight of the signage= 48.13kg

48.13

-

2.95

... More
Dismantling steel work in built up sections in angles, tees, flats plates,Tube and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Direction Signboard Type-16 - 1.3mx1.5mx10mm, including tubes, name plate etc. Total weight of the signage= 51.13kg

51.13

-

2.95

... More
Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : Direction Signboard Type-8 Precast concrete Signage - 1.0M X 2.0M X 0.05M

0.1

-

1365.25

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Chevron Signs - (600 x 500mm)

12

-

4800

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Object Hazard Marker - in all Culverts ( 900x 300mm)

36

-

3400

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Speed Limit Board - (600mm circle)

10

-

4723

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Directional Boards ( 1.2m x .8m ) indicating the Building Block/House No. Sets

15

-

14555

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Map Sign Board ( 3.6 m x 2.4 m)

4

-

112500

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Facility Sign Board ( 600mm x800mm)

5

-

3337

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Entry / Exit Sign Board ( 600mm x 800mm)

6

-

3347

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Safety & Awarness Signages (1.2m x 0.8m)

10

-

14504

... More
Providing and erecting Cautionary/Mandatory, direction and place identification retro-reflectorised signs made out of cube corner Micro Prismatic Grade Sheeting confiMetreing to Type-XI standards of IRC:67:2012 and ASTM D 4956-09, specification and fixed over 4mm thick ACP sheet fixed over a back supporting frame of 25mm x 25mm x 3mm mild steel angle and supported on a mild steel Pipe of 55NB-60NB with clear height of not less than 2.10m from the ground level and (1.2m for Hazard Marker) the sign post should be painted as per IRC 67-2012 and fiMetrely fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm x 45cm x 60cm size including cost and conveyenance of all materials, equipment, machinery and labour with all leads and lifts, loading charges necessary for statifactory completion of the work as directed by the engineer in charge. Micro Prismatic grade Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 year warranty issued for field perfoMetreance and a certified copy of three years outdoor exposure report shall be obtained. Welcome Sign Board (2m x 1.4m)

1

-

57130

... More
Supplying and installation of Flexible Median Marker delineators (road way indicators, hazard markers) as per IRC 79-2019 for improving median visibility of the road.It shall be made from a combination of tough, high impact resistant engineering theMetreoplastic material with edge sealed and U shape structure having rebound/ bounce back property having overall height, width and body thickness not less than 180mm, 120mm and 6.5 mm respectively. The reflective sheeting shall be of Type XI Florescent Yellow as per IRC : 67 and it should be on both the face . The logo of the manufacturer shall be embossed on either side of the body in the injection molding process . The body of FMM shall bounce back to its original position after 750 numbers of hits using pendulum of 1.8 Kg confoMetreing to ASTM D 256. It shall be fixed by a combination of epoxy adhesive and grouting/Drilling on concrete medians or properly constructed solid medians. (Make 3M or Higher) Location : On the divider of 2 lane road from ATM to Corporate Building Security Gate.

240

-

350

... More
Part D Rain Water Harvesting (For 15 Recharge Pits)

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.

140.7

-

135.25

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m

452.7

-

254.35

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Hard rock (blasting prohibited)

154.8

-

783.35

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).

140.7

-

127

... More
Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre).

14.1

-

315

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

10.95

-

5229.2

... More
Tile brick masonry with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)

103.2

-

8208.95

... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster

395.55

-

337.15

... More
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Precast Slab

9

-

9596.85

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. Reinforcement @ 130 Kg per cum of precast slab

1169.4

-

81.65

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100 mm dia. R.C.C. pipe (inlet)

300

-

341.95

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe (outlet)

150

-

380.35

... More
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Chamber inlet pipe and outlet pipe

45

-

4697.1

... More
Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part I). MS Shutter 100mm dia

15

-

621.4

... More
Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part I). MS Shutter 150mm dia

15

-

331.05

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineerinr-in-charge, upto 90 meter depth below ground level. Rocky strata including Boulders 300 mm dia

285

-

1030.55

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia

90

-

816.25

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Filter Media -1 (Boulder)

4.65

-

1131

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Filter Media -2 (Gravel)

7.5

-

1549.15

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Filter Media -3 (Pea Gravel)

7.5

-

1428.75

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: With 20 mm diameter round bar (Steps)

60

-

307.5

... More
Providing dual flush toilet cisterns At corporate building toilets / urinals

33

-

677.97

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.