Indian Port Rail And Ropeway Corporation Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Indian Port Rail And Ropeway Corporation Limited - IPRCL Tender

Works
Civil And Construction
Electrical Works
Cable and Wires
Eprocure
Opening Date8 Jul 2022
Closing Date10 Aug 2022
Tender Amount₹ 7,24,16,836 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Optical converter card SPHC-PA-NIVOX

12

-

354036

... More
EI Main rack

1

-

371070

... More
LEU Rack

3

-

360000

... More
Relay rack

1

-

77456

... More
Design of EI system

1

-

1008700

... More
Inter connecting cables ,conector,terminals mounting arrengments, fixures and accessories to make EI system functional (Central)

1

-

904204

... More
Inter connecting cables ,conector,terminals mounting arrengments, fixures and accessories to make EI system functional (LEU)

3

-

205258

... More
E-P5 subrack with mother bord

1

-

357223

... More
SM-480 Relay

1

-

19842

... More
NOTE:

-

-

-

... More
Before placing order for all the materials to the firms concerned, prior approval to be obtained from IPRCL's Engineer.

-

-

-

... More
REQUIREMENTS OF ELECTRONIC INTERLOCKING SYSTEM

-

-

-

... More
The Electronic Interlocking system supplied shall have approval of RDSO as per specification no.RDSO/SPN/192/2005 or with latest amendment.

-

-

-

... More
The Electronic Interlocking system shall be complete with power supply arrangement.

-

-

-

... More
The equipment shall be provided with all the necessary and recommeneded protection devices for lightening and surge protection.

-

-

-

... More
Tenderer shall ensure that the installation of electronic interlocking system equipment shall be done by manufacturer of the equipment/their authorized technical staff.

-

-

-

... More
Necessary technical documents,installation & maintenance manuals,trouble shooting procedure details and any other required technical information regarding Electronic interlocking system supplied shall be provided to ensure proper installation/maintenance/repair of Electronic Interlocking System as per manufacturer's specifications/stipulations.

-

-

-

... More
Tenderer shall be provide training of IPRCL/Railway's officials in software and hardware to enable maintenance of supplied electronic system.The quality of training should be such that at the end of the training the Railway officials will be able to install/commission and maintain the equipment.They shall be trained in all aspect of system design, engineering inspection,testing, exeution,commissioning,fault diagnosis operation and maintenance of the system as whole and also all constituent equipments.Training shall be imparted preferable at work site/Railway depot nominated by engineer in charge/ manufacturer's premises.training material shall be supplied by contractor.

-

-

-

... More
Tenderer should submit authorization from Original Equipment Manufacturer to supply of equipment against this tender, if awarded.

-

-

-

... More
Tenderer should submit the commitment from Original Equipment Manufacturer for supply of spares if required, for next five years, if awarded.

-

-

-

... More
Supply of documents (Manuals for Installation, Testing, commissioning and maintenance of the system) (One set consist of 6 set of following drawings per Station). (i) Manual for installation, Testing, Commissioning and maintenance of the system for Technicians / Jr. Engineers. (Installation & Maintenance level) (ii) Functioning and system overview (Higher management level).(Higher management level). (iii) Completion documents as per special conditions of contract. iv) Design & Supply of circuits and plans to suit layout given in the signaling plan for Hot Standby Architecture Electronic Interlocking (EI) system. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD. This will include supply of Control cum Indication panel / VDU diagram, Square Sheet, Wiring Diagrams (Application Logic and Interface Circuit), Fuse Analysis, Contact Analysis, Tag Block Analysis, Power Supply Distribution / Power equipment arrangement (with program switch) Diagram, Auto Change over diagram (if supplied by the contractor), and all other relevant drawings.

1

-

106827

... More
NOTE: The contactor shall initially supply 1 set of documents (Paper Prints) for approval of Railways/IPRCL.He shall ensure the each sheet has a block for signature of Railway/IPRCL's official as well as a block for signature of firm, duly signed by the authoriesed signatory of the firm. The name of the work as given by Railways/IPRCL shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. After approval of documents by Railways, the contractor will make copies of the approved documents and return the approved document to Railways/IPRCL. The contractor will then make necessary correction to Application Logic software duly incorporating Railways/IPRCL' alterations/ corrections/ comments, if any. After Complete Testing / Commissioning of the station, tracings of completion documents as mentioned above will be submitted to Railways/IPRCL for approval. Along with the Completion application logic, difference report (showing addition & deletion in different colours) as compared to earlier approved application logic should also be submitted. After approval of completion application logic by Railways/IPRCL, 5 sets of copies of completion tracings will be submitted to Railways/IPRCL.

-

-

-

... More
Portable work station for Data input & configuration with necessary software/ programs / Accessories, simulation and functional testing, diagnostics and trouble shooting and commissioning of EI system. Suitable table and chair of reputed make shall be supplied by the contractor. Note: The specification of portable work station shall be as per Technical specification given in Annexure or higher version as approved by Engineer In-Charge. All the required software should be uploaded Licensed CD should be given along with software.

1

-

208786.93

... More
Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations as per schedule item 1 above. (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose pliers etc. & measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at site). Each set comprises of the following :- * Crimping tool for all types of special cable assembly used in EI system .* Insertion tool for all types of special cable assembly used in EI system. *Removal tool for all types of special cable assembly used in EI system. * Digital multimeter (Fluke 111 or better) * Steel cabinet/ Almira, Size: 1980mm height, 915 mm width and 485mm depth (Godrej Make/Jalaram) of good quality to store tool, spare cards and documents * Steel Book rack Size: 1850mm height, 900 mm width and 316 mm depth for keeping documents. (Godrej Make/Jalaram) * Clamp Earth Tester. * Clamp Current Meter.

-

-

184312.53

... More
Transportaion of EI system VoCPT to Manikpur

1

-

75730.2

... More
Indoor

-

-

-

... More
Supply, transportation, erection, and grouting of Composite relay Racks/ Relay Racks/ Ct Rack as per Drg No. SK/DRG/OL/SER/192, SH1/2 (For composite Relay Rack), Drg. No. SK/DRG/OL/SER/192, Sh-2/2 (For Relay Racks) and Drg No. S%T/CON/HQ/VSKP/95/92 (For CT racks) respectively, including fixing of Racks, PBT terminal 1 way/6 way, Nd foses Bus Bars, Eyelets ,Hylaum sheet or required thickness (12mm) as per length required at sites, condensers/registers etc. where ever required as per direction of site engineers. The material to be inspected by authosied engineer before installation. Tenderer shall supply all materials from RDSO approved sources such as PBT terminals 1-way/6 way, ND fuses, Fuse Blocks, Bus bar, Eyelets, Hylumstrips(!2 mm thickness of ISI mark ) condesers, resistances etc., and any other materials required for this work at his own cost.

4

-

77509.95

... More
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments.

-

-

-

... More
Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Wago type fonix make or simillar.

5000

-

80.37

... More
Supply of End plate for above item (I) 2.5mm/0.091 in thick as per site requirement.

500

-

15.16

... More
Supply of End Stopper for above item (I) 10mm/0.0394 in width as per site requirement.

500

-

15.16

... More
Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.

200

-

156.2

... More
Markers strip for above item (i)

500

-

22.75

... More
Indoor Relays

-

-

-

... More
Neutral Relay QN1, Non AC immunized, 8F-8B, 12F-4B 24VDC along with plug board, retaining clip and connectors. Conforming to BRS 930A, IRS: S60, IRS: S34 & IRS: S23.(No of each configuration will be decided by Engineer In-charge)inspection by RDSO

130

-

5155.5

... More
Relay QNA1, AC immunized, 8F/08B, 12F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS: 931A, IRS: S60, IRS: S34 & IRS: S24.(No of each configuration will be decided by Engineer In-charge)inspection by RDSO

75

-

5337.15

... More
Universal relay plugin type stlye AC/LED all aspects AC lamp proving relay unit with in built current transformer type, slow release neutral line relay 4F/4B contacts, front and back contacts metal to carbon, shall be suitable for working in series with the 110AC LED signal lamp rated at 15W confirming to RDSO spec no BRS:941A, STS/E/Relays/AC LIT/LED signal/09-2002, amend-1 with latest inspection by RDSO (QECX-61)

40

-

5265.75

... More
Supply of Relay QNN1 (configuaration 6F-2B or 4F-2B) inspection by RDSO

5

-

4858.92

... More
Supply of Point Group PI, Siemens type (No RSSK 31/0001)inspection by RDSO

18

-

48963.4

... More
Supply of electronic time delay device(configuration -1 min)

5

-

2947.81

... More
Supply of Main cable Termination rack complete along with  patching cable of 24 core.

5

-

47240.54

... More
Wooden Rack with table for  Dual VDU as per site requirement

1

-

134076.42

... More
Supply of QNNA1

14

-

5102.85

... More
Total Supply Indoor (A TO C)

-

-

-

... More
Cable/wires

-

-

-

... More
CABLE SIGNALLING UNDERGROUND, ARMOURED, UNSCREENED, PVC INSULATED,PVC SHEATHED,ANNEALED COPPER CONDUCTOR SIZE: 24 CORE X 1.5 SQ.MM AS PER RDSO SPECN. NO. IRS:S:63/2014 REV.4.0 or latestInspection by RDSO

-

-

373315.46

... More
CABLE SIGNALLING UNDERGROUND, ARMOURED, UNSCREENED, PVC INSULATED,PVC SHEATHED,ANNEALED COPPER CONDUCTOR SIZE: 12 CORE X 1.5 SQ.MM AS PER RDSO SPECN. NO. IRS:S:63/2014 REV.4.0 or latest. Inspection by RDSO

25

-

238948.82

... More
CABLE SIGNALLING UNDERGROUND UNSCREENED PVC INSULATED PVC SHEATHED ARMOURED ANNEALED COPPER CONDUCTOR SIZE 6 CORE X 1.5 SQ MM AS PER RDSO SPECN NO IRS: S:63/2014 (PL NO 56114308) or latest Inspection by RDSO

-

-

138734.12

... More
PVC INSULATED, ARMOURED, UNSCREENED, UNDERGROUND , RAILWAY SIGNALLING CABLE AS PER RDSO IRS S:63/2014 REV 4 OR LATEST.SIZE:2 CORE X 2.5 SQ.MM or latest. Inspection by RDSO

-

-

95047.21

... More
PVC INSULATED,UNSCREENED ARMOURED, UNDERGROUND POWER CABLE SIZE 2 CORE X 25 SQ.MM ALUMINIUM CONDUCTOR, RDSO SPECN.NO.IRS-S-63/2014 NO.IS:1554 (PART I) or latest. Inspection by RDSO

1

-

138956.67

... More
6 QUAD 0.9MM DIA JELLY FILLED UNDERGROUND CABLE AS PER RDSO SPECN.NO.IRS:TC:30/2005(VER-1) WITH AMNDT.NO.4 or latest . Inspection by RDSO

12

-

391114.66

... More
24 Fibre armoured optical fibre cable as per RDSO apecification No.IRS-TC/55/2006 Rev.1 with latest amendents no. 2 or latest Note- This item reserved for RDSO approved sources only. Inspection by RDSO

10

-

97444.71

... More
PVC insulated Railway Signaling Indoor Single core wire conforming to IRS 76/89 (Amd3) or latest. Note: - Wire Colours shall be decided by engineer - in - Charge.

-

-

-

... More
1 x 0.6 mm

-

-

3709.33

... More
1X 1 mm

-

-

8657.63

... More
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3).

30

-

6960.86

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89.

-

-

51487.36

... More
Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 + 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89.

3

-

165671.19

... More
Data logger

-

-

-

... More
Supply of DATA LOGGER as per RDSO's Specn IRS:S:99/2066 Amd No.3 or latest with configuration of 1024 digital inputs and 64 Analog inputs with self power supply system, protocol converters as required etc with networking facilities. Inspection of Datalogger by RDSO & balance item by representative of Railway.This includes supplying of two no.s of door sensors for each data logger.Inspection by the representative of Railway.

1

-

681860.55

... More
Point Machine Health monitoring Unit with 24V Charger and 24V, 42 AH maintenance free battery.

-

-

271807.86

... More
750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make as per Engineer in-charge.

1

-

43788.61

... More
Digital Axle Counter Multi Section

-

-

-

... More
Supply and execution Multi section Digital Axle Counter Multi Section complete system including central evaluator(s),final track clearance relay for each track section, Reset boxes, LV boxes, detection points, mushroom housing for track side electronics and all other accessories fully wired to the ultimate capacity and fully equipped to the configuration specified as per RDSO’s specification No. RDSO / SPN / 176 / 2013 (ver.3) or latest and OEM specification for 14 Detection Points & 10 Track Sections

2

-

7571479.8

... More
Fuses/ Fusechangeover/ SM office

-

-

-

... More
Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar).

-

-

72.79

... More
Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A (System, Rapid, Malnad or RBCO make or similar).

-

-

27.3

... More
Indicative type Fuse Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS:S-80/92

50

-

50.04

... More
D type fuse block non indicating type low voltage non detorating fuse base suitable for fuse link of capacity 2A/6A/10A/16A as per specification IRS:S-80/92 or latest . Quantituy break up of each type of fuse block will be specified by Engineer in-charge.

100

-

43.98

... More
D type fuse link non indicating type low voltage non detorating, capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge.

100

-

45.49

... More
Fuse auto changeover system for used in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments.. One Automatic changeover Unit comprise 32 nos. of external Non Deteriorating Type or ‘G’ type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card.

-

-

46788

... More
Fuse auto changeover system for used in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprise 24 nos. of external Non Deteriorating Type or ‘G’ type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card.

-

-

70773.01

... More
Earth Leakage Detector as per RDSO/SPN/256/2002 with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and – 10% tolerance.

-

-

164761.8

... More
Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments.

15

-

4517.62

... More
Sealing wire used for sealing of signaling relays & equipments.

1

-

256.29

... More
Lead Tablet for sealing wire used for sealing of signaling relays & equipments.

1

-

304.81

... More
Fire Extinguisher CO2 type (capacity 5 kg.)

4

-

9729.79

... More
Office Chair makes Godrej CH-7B or similar of reputed brand.

3

-

3691.13

... More
Office Revolving Chair Godrej Make Model No.9u02r Bravo Or Similar of reputed brand.

3

-

11258.41

... More
Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 or Similar of reputed brand.

2

-

22040.65

... More
Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand.

1

-

23849.82

... More
D-link Wall mount rack, steel frame 347mm with usable hight 267 mm depth- 450mm width 550 mm, 06U poweder coated rack with 19 inches mounting angle. conformation to spec. DIN 41494 wall mount Rack - NWR-6U-5045-GR or similar of reputed make.

-

-

5802.3

... More
Supply of Paffy premium light waight aluminium Heavy duty folding step ladder- Maple 6 steps with 7 years warranty Made in iIndia. Holding capacity 120-150 Kg, weight 8.5Kg.

1

-

5915.7

... More
Supply of Ultrasonic Rat Repeller (Triple Action 3 in 1) Tele Net make protected area 1100 Sq. Ft. operating on 220 - 240 V AC.Runeeing 24 Hrs X 7 Days.

1

-

6952.05

... More
Power supply

-

-

-

... More
SMPS based Integrated Power Supply System for EI in RE area up to 6 Line, as per RDSO/SPN/165/2012 version -3 or latest . This includes transportation, installation and Commissioning of Integrated Power Supply System.

1

-

1987153.61

... More
Self contained, Air cooled, and Diesel Generator set along with canopy, 10 KVA single Phase of Kirloskar or other reputed make with sound proof enclosure and A.M.F. with following sub-components: a)    Engine: EA 16ES Type, air cooled, diesel engine developing minimum 16 BHP at 1500 rpm with accessories and with ISI mark. Suitable capacity battery make Exide/ Prestolite / Standard (12V/ 35 AH minimum) with leads for starting arrangement. b) Alternator 10 KVA single phase 1500 rpm, 0.8 power factor, 50HZ, brushless make CGL/KEC/LS. c) Engine and alternator close panel equipped with voltmeter, ammeter, frequency meter, MCB etc. d)    Minimum 50 liter Fuel Tank with continuous running capacity. e) Acoustic enclosure. CPCB approved. f) A.M.F. Auto mains Failures panel consisting Micro processor based make: PECO/G - TECH / Utopia. AMF Panel should be outside DG set for Auto/Manual operation.

1

-

363717.69

... More
Auto changeover Power Panel suitable to change over between three incoming single phase 230V supplies with signaling supply distribution arrangement, voltage sensing relays, MCB's, fuses & contactor Unit as per Drawing No. DRM/SG/743. Note:-i).    Item include supply of 10 spare fuses of each type, 1 contactor relay of each type & 1 MCB of each type used in panel. ii). Program switches & wire to be supplied based on current requirement. iii).  The cabinet of Auto changeover shall be powder coated & in compact in size as possible.

1

-

131541.75

... More
Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.

50

-

49931.7

... More
Transient Surge Suppressor Electronic Grade Surge protective device (Surge) current Capacity 50 KA as per following Specifications: - 1) Connection Type: Parallel, 2) Nominal discharge current: 3KA, 3) Response Time : 0.5 nanoseconds, 4) Status Indication: LEDs, Dry Contacts.

1

-

75648.52

... More
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 25A, 9 poles, and 3 positions make Siemens / Thakur or Similar.

-

-

8013.13

... More
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 63A, 9 poles, and 3 positions make Siemens / Thakur or Similar.

-

-

16669.24

... More
Rubber Mat for Power Equipment room. ( 5mm thick )

20

-

156.2

... More
Supply of solar photovoltaic system as per RDSO spec IRS-S-84/92 or latest RDSO specification for charging the lead acid battery 110V/300AH & to cater the steady load of signalling system consisting of following : i)Solar PhotoVoltaic module 12V/70W + 5% connected 9 in series and 10 in parallel( 9X10=90 nos. Per system) ii)Solar charge controller of 110V, 100 A capacity.iii)M.S Mounting structure with hardware for the above modules.

1

-

1703650.03

... More
Points

-

-

-

... More
Supply of Electric Point Machine Non Trailable Design, 143 mm throw with lock detector, cable termination box and slide for lock and detector, low thrust rotary locking type, AC immunity 160V AC as per specification IRS - S - 24/2002 amd. 1 or latest as per drawing No. 10800. (IRS Type) This includes Set of tools in suitable tool box (along with every set of eight point machine or less). Inspection by RDSO

20

-

155990.1

... More
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement)

20

-

1891.06

... More
SIGNAL

-

-

-

... More
Supply of 5.6 Mts CLS tubular steel post specification No.IRS: S-6/81 with latest Amnd to suit 140 mm dia base.Inspection by the Representative of Railway.

-

-

12175.8

... More
Pad locks Godrej make, Hardened Nav -Tal 7 lever, 65mm dia with common key or similar product having same feature & technical data.

10

-

263.87

... More
LED Signal Lighting unit for main signal as per RDSO SPN 153/2011 with latest Amd and drg.SA:23002 :S 23024/M (Red)

-

-

13345.1

... More
LED Signal Lighting unit for main signal as per RDSO SPN 153/2011 with latest Amd and drg.SA:23002 :S 23024/M (Yellow)

-

-

13345.1

... More
LED Signal Lighting unit for main signal as per RDSO SPN 153/2011 with latest Amd and drg .SA:23002 :S 23024/M (Green)

-

-

15013.24

... More
LED Signal Lighting unit for Calling ON signal as per RDSO SPN 153/2011 with latest Amd and drg.SA: 24352 :S 23463.

-

-

11022.9

... More
LED Signal Lighting unit for Route indicator as per RDSO SPN 153/2011 .SA:23401 with latest Amd and drg:S 23407

-

-

9725.24

... More
LED Signal Lighting unit for Position light shunt signal as per RDSO SPN 153/2011 with latest Amd and drg.SA:23840 :S 23841

70

-

9725.24

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- 8 and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

-

-

39234.6

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

-

-

41102.91

... More
Calling ON Signal Unit with Brackets & Fixing accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv) Alt1 suitable to LED Signal Lighting Unit.

-

-

1447.95

... More
Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R

-

-

6540.62

... More
Junction route indicator unit 4 way (Without Lenses & Holder) as per Drg. No. RDSO SA 23403 suitable for LED Signal Lighting Unit & as IRS:S-66/84 amndt-1 or latest. (Supply of LED Unit is not covered in this item)

-

-

30894.93

... More
Junction route indicator unit 5 way (Without Lenses & Holder) as per Drg. No. RDSO SA 23402 suitable for LED Signal Lighting Unit & as IRS:S-66/84 amndt-1 or latest. (Supply of LED Unit is not covered in this item)

-

-

34437.9

... More
Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item)

18

-

18171.3

... More
Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item)

2

-

13297.2

... More
Different warning Boards used for Railway Signaling system as per RDSO Drg. No. SA2380 (Adv). This includes Painting and retro reflective arrangement should be as per SEM.

2

-

6798.42

... More
Medium Class G.I. Pipes to IS : 1239 (Pt.I)-2004 or latest ; 100mm dia. ( int. dia) 3.65 mm+/- 10% thick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.

-

-

837.1

... More
RCC pipes of 150mm internal dia (2 meter long) along with collars as per IS No. 458/2003 of NP type.

200

-

366.99

... More
Half Round RCC pipes & collars of 150 mm internal dia (2 meter long) along with collars as per IS No. 458/2003 of NP type

50

-

488.31

... More
Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2 meter long) along with collars as per IS No. 458/2003 of NP type

-

-

994.82

... More
Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd.

5

-

3149.75

... More
Supply of distilled water plant/dimineralised plant of (10-50-100 litre per hour) make laptech/shivam or indicated by railways. Inspection by Rep. of CSTE/Project/BSP

1

-

28841.4

... More
200 way tag block spec IRS-S-77/91 with latest amend and with Drg no SA-24751, 52, 53. inspection by Rep. of IPRCL

-

-

3250.8

... More
20 pair CT box inspection by Rep. of IPRCL

5

-

2539.95

... More
Supply of Double walled corrogated pipe length 6 metre, 120mm outer dia, 103.5mm inner dia with couplers as per specification no BSEN 50086-2-4 for under ground power/communication/signal cable protection. One six metre pipe with collar at both end shall be counted a unit for the purpose of payment. inspection by Rep. of IPRCL

-

-

1447.95

... More
Timer relay fail safe type of electronic time delay device 24 volt DC (Anuvidyut make or similar) for Rly signalling as per spec no IRS:S-61/2000 with latest amend. The interlocking code pin for this unit shall be AFGKY (with a time setting of 120 seconds) inspection by RDSO

-

-

2671.2

... More
Timer relay fail safe type of electronic time delay device 24 volt DC (Anuvidyut make or similar) for Rly signalling as per spec no IRS:S-61 with latest amend. The interlocking code pin for this unit shall be AFGKY (with a time setting of 60 seconds) inspection by RDSO

-

-

2671.2

... More
Apparatus cases & terminals

-

-

-

... More
ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

200

-

100.09

... More
Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys.

12

-

21905.68

... More
Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two nos E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys.

8

-

13834.93

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied

-

-

10157.7

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied

25

-

6518.4

... More
Tic-tac Piano type Switches & sockets,holders , 5A (ISI mark of reputed make)

5

-

43.98

... More
Block instrument with BPAC (SSBPAC - D)

-

-

-

... More
Supply of Solid state Block proving by Axle counter for Single Line. This includes i) Microprocessor based SSBPAC (D) including wired relay rack with relays as per RDSO /SPN/175/2005 or latest. ii) Station masters block panel as per RDSO /SPN/175/2005 or latest along with Block telephone as per RDSO /SPN/191/2006 or latest. iii) Supply of lighting and surge protection device for power line and Data line.

-

-

1128690.15

... More
Supply of automatic midia changeover for SSBPAC(D) this includes Autochangeover card with one voice modem circuit and one EI converter circuit and lighting and surge protection device for Data line.

-

-

101460.45

... More
High Availability Single section digital axle counters with Dual sensor system as per RDSO/SPN/177/2012 version 3 or latest. This includes The supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital relays, PR Relays, Clamp with deflector plates & hardware, Dual display reset box with auto resetting facility, Surge voltage protection devices and filter card to be mounted on din rail etc as per OEM for complete installation & testing & commissioning of (HASSDAC) system NOTE: One set of HASSDAC system will include equipment required to monitor One Up line or One Dn line of a full Block Section between two stations.

-

-

1094207.1

... More
Telecommunication

-

-

-

... More
Motorola VHF Mobile Synthesized Trans-receiver, Model-GM-339, 146 to 174 MHz frequency range 16 programmable channels, 25 watt RF power out put maximum 2/5 KHz channel specing compact palm microphone, Cable and hang up clip, non locking mounting bracket power cable, limited accessory connectors front facing internal speaker operators handbook mini UHF Male to Female adaptor (Antenna) is not included.. Inspection by RITES.

2

-

31734.11

... More
Supply of VF tapping transformaer 1120:470 IRS Spec TC-22/76 with latest amend. Inspection by RDSO

4

-

1089

... More
Supply of VF tapping transformaer 1120:600 IRS Spec TC-22/76 with latest amend. Inspection by RDSO

4

-

1176.58

... More
Supply of external leased line modem as per RDSO spec no IRS:S-99/2006 amend 3 or latest. Inspection by Rep. of IPRCL

-

-

29474.55

... More
Supply of composite rack covered with frnt transperent doors to house 2 SDH, 2 Opti MUXs/OLTEs and Two PDMUX alongwith PDP, DDF, cooling Fans, MDF for 100 pairs with antisurge protection through fast acting fuses & GD tubes FOOT NOTE; The SDH, Opti MUX, PD mux Cross connect shall be mounted in a composite rack. X,Y,Z protection for system equipments at each location shall be provided by the tenderer to protect the equipments

-

-

34001.1

... More
Supply and installation of krone type DPs of 50 pair suitable for 9 mm dia cable with GD tubes and fuses fitted in box with plastic cover duily mounted on good quality teak wood / hylum board.

-

-

-

... More
50 pair kron DP - supply

1

-

6401.85

... More
Instalation of above Krone DP

1

-

2134.65

... More
Supply of way station equipment wtth necessary mounting arrangement on composite rack or on wall' It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection by using 3 way ampliirer. These way station equipments shall drive telephones which shall work on 2-wire mode up to 2 km with dialing facility and shall also have provision for gain adjustments for trains and receive channel along with a separate setting for DTMF trains-receive channel with ringing pattern setting arrangement as per RDSO specification No.RDSO/SPN/TC -66/07 amd.3 or latest.

1

-

56233.8

... More
Supply of CLI push button telephone suitable for connection with way side equipment and the system mentioned above as per DOT/TEC specifications no.TEC/GR/CP/TeIe-002-/05 Jan 2010 with latest amendm.

4

-

1461.6

... More
Wall clock Quartz make Samay model no. SQ587 or SQ129785 with sweep second or similar make/model of Ajanta M no.-957 or sceintife with 1.5 volt Eveready cell.

1

-

210

... More
Supply of two way Line cord 1.5 mtr length with RJ-11 connectors both side of make Link Tele, Lotus, Access.

10

-

11.55

... More
Fabrication and Supply of EMC socket post and erection of fabricated assembly at the location indicated in the route chart and as per the direction of site engineer. This includs cutting of GI pipe to the required size, supply and welding of GI pipe and base plate, fixing of emergency socket box, transportation of material at site, digging of pit and erection of whole assembly, termination of derivation cable on the strip inside the emergency socket box, All material, tools, plant and machinary shall be arranged by the contractor.

-

-

11815.65

... More
Supply of HDPE telecom duct 40mm dia ,solid permanently lubricated inner dia 33mm & wall thickness 4mm as per Tecspefn.G/OPT-08/01 Dec-99 with amendSwith end plugs,couplers , cable sealing plug and duct coller etc. To be supplied from TEC approved sources with all accessories suitable for OFC CABLE OF SIZE 24 FIBRES ARMOURED hdpe 40/33 MM DUCT.

10

-

62238.75

... More
SUPPLY OF 2X24 FIBER OPTIC SPLICE STRAIGHT JOINT ENCLOSE (SJC) COMPLETE AS PER RDSO SPECN NO. RDSO/SPN/TC/68/2014 Rev 1 AMENDMENT.1

5

-

3105.9

... More
Supply of following types of twisted pair PVC switch board cable, conductor of size 0.6mm. dia annealed copper conforming to IRS-TC-24/91 or ITD 1138. Inspection by Rep. of IPRCL.

-

-

-

... More
(a) 5 pair

100

-

25.36

... More
(b)10 pair

100

-

41.49

... More
5 Watt transceiver VHF set Kenwood TK-7160 or similar, along with battery charger and rechargable spare battery pack

4

-

6511.05

... More
Tools / Measuring Instruments

-

-

-

... More
Standard Tool kits, Test and Measuring instruments required for Installation, testing, commissioning & maintenance of HASSDAC. Kit will includes all tools & measuring instruments required for Installation, testing, commissioning & maintenance of HASSDAC as per OEM

-

-

168210.27

... More
Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second or Superior.make Fluke/Kusum/Meko/ Motwane/Stanlay/Megger.

2

-

58398.42

... More
Maintenance of Tool kit as per Annexure.

1

-

111559.91

... More
Road Measuring Cycle, made of Aluminum with 05 digit counter, foldable with bag.

-

-

5699.36

... More
Professional AC/DC clamp meter 3 ¾ digit , true RMS measurement, For Measurement of DC/AC currents up to Minimum 0.1 Amp, with set of leads & carrying case. Model - Mastech MS2101 or equivalent/ higher make Motwane/Stanlay/Fluke/Kusum/Meko/Megger.

2

-

18490.85

... More
Supply of optical power meter as per specification . SPECIFICATION: ATM 100 Optical Power meter.1. 270,1000,2000 Hz tone detection 2. Wide measurement range :- Max. 78 dB,high resolution : 0.01 db, good accuracy :0.2 db 3. Insertion loss test in db 4.SM or MM applications, 5.FP/PC and 2.5mm universal connector 6. 850/1300/1310/1490/1550nm calibrated wavelengths 7. ATM 100 is for telecom testing 8. Energy save mode: about 1C minutes no operation will cause the device automatic power off (can be cancelled) 9. Reference value storage 10. Full energy can support above 100 hrs operation. NOTE: 1. Price not to exceed MRP. 2. LD as applicable 3. A zerox copy of the delivery challan may be submitted to office

1

-

8678.25

... More
Supply of telecommunication tools set 50 pieces at least including various screw drivrs and soldering iron etc. similar to Stanely 89-883 53 pcs telecommunication tool set.

1

-

9941.4

... More
Supply of universal tool kit similar to Tapariya 1001

1

-

661.5

... More
Rotary Electric Key Transmitter (HKT/EKT) single complete to Drg.No.SA-22601 (Adv) Alt.4 and specn.No.IRS.S.21/2001 amend.1 or latest. Ward Number to be decided by site in charge.

6

-

9960.3

... More
Spare

-

-

-

... More
Supply of spare card for SSDAC Axle counter to suite for supply item in schedule A

-

-

-

... More
Signal Conditioner card No. (SCC1) For SSDAC as per RDSO specification No. RDSO/SPN/177/2012 with version 3 or Latest.

-

-

51711.57

... More
Signal Conditioner card No. (SCC2) for SSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3 or latest.

-

-

51711.57

... More
Modem card No.3 for SSDAC as per RDSO specification No. RDSO/SPN/177/2012with version 3 or latest.

-

-

51711.57

... More
Dual Micro Controller Logic card No.4 for SSDAC.

-

-

138586.65

... More
Relay Driver card No. 5.

-

-

51711.57

... More
DC-DC converter Card no. 6.

-

-

31026.94

... More
Reset box for SSDAC as per RDSO No.RDSO/SPN/177/2012 with version 3 or latest

-

-

74465.36

... More
Total Supply outdoor ( D TO P)

-

-

-

... More
Total Supply

-

-

-

... More
Execution

-

-

-

... More
EI

-

-

-

... More
Installation, wiring, programming, testing( FAT & SAT) and commissioning of EI equipment supplied as per supply item NO.1above including transportation from consignee depot to site as per original manufacturer's specifications & RDSO specification STE/E/TAN/3012 dt.28.04.2014 or latest and provision of NMS for OFC as per TAN no/STS/E/TAN/3012 under supervison of OEM's Engineer/ authorized representative. This also cover the installation networking of datalogger.

1

-

824694

... More
The tools/ equipments/ materials/ simulation boards required for testing shall be supplied / fabricated by contactor. this included replacement of modules/ cards/ LEDs/ equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets, surge & lightning protection boxes shall be supplied and installed by the contractor. 230V supply shall be arranged by Railways. In case supplies are required to be extended, from Power room / relay room then same shall be extended by the contractor with his own materials such as 1X16 sq mm wires, cables, lugs, RCC/GI pipes, insulated ladders etc. After ST/LT testing, Factory Acceptance Tests (FAT) & Square Sheet testing system should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer-in-charge.

-

-

-

... More
After installation of EI System, Maintenance & Supervision for One year, as per details given in Special Condition of Contract, Technical requirement & SEM.

1

-

368368.77

... More
Alteration in wiring,installation, testing & commissioning of the item scope details of item no 1 , the brief scope of work include but not limited as follows; 1.Alteration in wiring, installation, testing and commissiong 2.All activity of FAT 3.All activity of SAT 4.GSIM testing etc. N.B - OEM need to certify the installation & functionally of the system.

1

-

1151424.76

... More
Training of Technician/ Jr. Engineer for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system. (Hard copies of training material/ course modules to be given to each participant).

30

-

2943

... More
Training of Officers for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system.(Hard copies of training material/ course modules to be given to each participant).

-

-

1607.48

... More
Earthing of EI equipment, relay racks and Power equipment etc to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note:- This will also cover the earthing & necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter 5 & Pre-commissioning check list of EI system.

1

-

185401.37

... More
Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on SR & the instruction of Iprcl engineer at site.

5

-

12732.44

... More
Installation, wiring, testing and commissioning of Data logger complete along with accessories using Contractors own wiring & fixing materials as per following configuration. (It includes loading of NETWORKING software, networking of data logger, installation of FEP & Fault diagnosis system). The requisite communication cable/channel for networking will be arranged by Railway. 1024 digital & 32 analog inputs / 2048 digital & 32 analog inputs

1

-

29940.04

... More
Installation, cable termination, testing and commisiioning of 20 pair CT boxes

2

-

2539.95

... More
Wiring of door detection proximity switch to the tag block of dataloggers/RTU (This includes provision of casing and capping and other wiring accessories, excluding 16/0.2 wire which will be supplied by Railways). Inspection by Rep. of CSTE/Project. This includes incorporation of this contact in datalogger simuation & datalogger report.

1

-

1304.1

... More
Installation, testing of door contacts and validation and proximity switch data through dataloggers/RTU. This includes incorporation of this contact in datalogger simulation & datalogger report.

1

-

1304.1

... More
Development of door 'close & open' software logics module and its implementation. Insp. By Rep. of Iprcl.

1

-

1304.1

... More
modification/alteration of dats logger/RTU digital input, validatory and yard simulation in both end station of IBS as per directive of Railway representative of Iprcl.

1

-

45625.65

... More
Provision of simulation arrangement (track and point simulation board as well as signal lamp simulation board) and its complete wiring; arrangement of free home, advance starters, IBS etc as may be required with block working with required temporary relay wiring for controlling the train movement in NI-period with the provision of temporary miniature operation cum indication panel board; deputation of fitter round the clock in NI-period for assisting simulation testing for all the routes as per approved RCC by the Railway officials; mobilization of additional man power attending to the pre NI block and commisioning of the station within prescribed time limit of NI-period as decided by the Railway officials; deputation of staff (one fitter and one helper) at the station for attending to the packing and realignment of point and crossing etc, in connection with Pway block for a period of 30 days beyond the commisioning date. station upto 6 lines

1

-

391068.3

... More
Provision of simulation arrangement (track and point simulation board as well as signal lamp simulation board) and its complete wiring; arrangement of free home, advance starters, IBS etc as may be required with block working with required temporary relay wiring for controlling the train movement in NI-period with the provision of temporary miniature operation cum indication panel board; deputation of fitter round the clock in NI-period for assisting simulation testing for all the routes as per approved RCC by the Railway officials; mobilization of additional man power attending to the pre NI block and commisioning of the station within prescribed time limit of NI-period as decided by the Railway officials; deputation of staff (one fitter and one helper) at the station for attending to the packing and realignment of point and crossing etc, in connection with Pway block for a period of 30 days beyond the commisioning date. station more than 6 lines

1

-

651780.15

... More
Supply of door proximity switches along with 2 way rigid connector for wire termination between proximity switches and datalogger tag blocks as per specs, inspection by Rep. of Iprcl.

2

-

702.45

... More
Installations, wiring, testing and commissioning of Point Health Monitoring System complete along with accessories with Contractors own material.

-

-

12727.89

... More
Installation wiring testing and commissioning of Fuse change over system (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible.

-

-

1298.11

... More
ASM Panel Room

-

-

-

... More
Fixing of KLCR relays in field in half location boxes or Steel rack in panel room as per the instruction of Rly engineer at site. Item includes supply and fixing of MS sheet and wiring of push buttons and LEDs for KLCR circuit. The KLCR relays, push buttons, LEDs to be fixed on a MS sheet of min.3mm in the half location box. The MS sheet should cover the full length and breadth of the half location box and can be in two pieces of approx. 48cm x 46cm and 80cm x 46cm. The first piece to be fitted on top and will contain the KLCR relays, LEDs and push buttons. The second piece to be fitted below the first piece to divide the two halves of the location box. Steel rack should be fixed on wall or as instructed by site engineer, in panel room. Relay fitting arrangement should be done such a way that KLCR relay frame can be slide out for wiring or incase of failure. All necessary arrangement shall be done by contractor for commissioning the KLCR. as per the instruction of site engineer. (Supply of KLCR relays, Location box, Steel rack is covered in Schedule A).

-

-

2380.89

... More
Supplying & fixing of crank handle box 450 x 250 x 150 mm made of 12mm thick teakwood with a glass front and padlocking and sealing arrangements per std practice. Pad lock to be supplied by the contractor. All material i.e. teakwood, handle, hinges, glass sheet of 3 mm thick to be supplied by the contractor. Box to be polished and description to be as per instructions of Engineer in - charge.

5

-

2057.88

... More
Wiring, installing of Magneto / DTMF telephone in ASM office, at locations, Relay Room, Point locations on both directions and siding Point Control locations as per instructions of Engineer-In-Charge for traffic purpose.

20

-

133.45

... More
Total Execution Indoor(A TO B)

-

-

-

... More
Power Supply

-

-

-

... More
Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of Thermo flasher relay, ELD's, fixing & wiring of change over switch (program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material. (This is for station)

1

-

151629.16

... More
Installation of LT Power Panel/ Power distribution panel/ Auto Changeover Panel, power supply equipments such as Rectifiers Transformers, Battery chargers etc including mounting on wooden planks/Hylem Sheet and complete wiring for automatic change over arrangement, mounting of Program switches on Bakelite sheet of size 300 mm x 300 mm x 8 mm fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires to be supplied by Rlys, lugs & glands to be supplied by Contractor.

1

-

30131.9

... More
Installation of Diesel generator set. This includes Casting of vibration free foundation, installation of control panel, outlet for exhaust, Laying of power cable from D.G. set to change over switch and wiring of D. G. set & control panel. Laying of cable/wires should be carried out in HDPE duct. This includes supply of all wiring, fixing & termination material of approved make required for the above work.

1

-

1154.05

... More
Supply and fixing of compact laminated sheet 20 mm for keeping S&T equipments as per instructions of Engineer at site. Commercially available thickness will be accepted as approved by Engineer in charge. This item includes supply of fixing materials like Nut, Bolts, Screw, Nails etc. Table for keeping axle counter resetting box and block instruments etc. can also be go fabricated under this item as per the design given by engineer in charge.

5

-

5890.04

... More
Supply, Errection, Testing and Commissioning of Automatic fire alarm system (AFDS) as per RDSO Specification RDSO/SPN/NEW/2010 Version 0 (Draft) or Latest. This include one year maintenance of the system

1

-

476703.69

... More
Supply & installation of Test board (LED, Pin tool type) for relay Room as per as per Drg No RST/C/105 A & B

1

-

16106.63

... More
Point

-

-

-

... More
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately

16

-

29507.84

... More
P way works required before interlocking a point such as squaring of switches, packing and levelling/alignment of track, easing or rails on either side of points to be interlocked, making proper spacing of slippers.etc

16

-

4048.85

... More
Axle Counter BPAC

-

-

-

... More
Installation of track device (double rail contact) including digging of trench, track crossing, laying of anti-rodent, anti-oxidant & non-flame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cable. The item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specification. NOTE: Installation/ programming/ configuration/ commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM.

-

-

10703.7

... More
Installation testing & commissioning of Single Section digital axle counter single section type system complete with track devices and other associated accessories. This include fixing of device, relays, wiring, lacing /dressing, cable termination with lug eyelet, drilling holes in rails, Installation of track devices and make it functional along with existing SSBPAC (D). Material required other then supply item of schedule A shall be arrange by contactor to make it functional.

-

-

21243.6

... More
Instalation, testing and commissioning of single line SSBPAC(D)

-

-

52059

... More
Signal

-

-

-

... More
Excavation and Casting of foundation for main signal post as per drawing No.RST/11173 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

-

-

10804.98

... More
Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge.

-

-

-

... More
2/3/4 aspect signal unit mounted on offset bracket with junction type route indicator 1/2/3 on multilamp lamp route indicators mounted on signal post

-

-

2600.85

... More
2/3/4 aspect signal unit mounted directly on signal post

-

-

1936.2

... More
Excavation and Casting of foundation for Shunt Signal as per Drg. No.RST/ 11173 with Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc for Casting of foundation will have to be brought by the Contractor at his own cost.

18

-

7603.67

... More
Erection of Position Light Shunt signal with Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site.

18

-

1402.8

... More
Cable laying

-

-

-

... More
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks or RCC half round pipes and back filling. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.

4500

-

401.87

... More
Digging of trench 1.2 M deep and, 0.3 Mtrs wide as per cable route plan & from rail flange/ road level and, 0.3 Mtrs to 0.6 Mtrs wide and back filling after laying of cable or placing of DWC/ RCC/GI pipe. (Laying of cable & placing of DWC/RCC/GI pipe coverd separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, and for Road Crossing, Drg. are to be followed.

1080

-

401.87

... More
Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches after laying DWC/RCC/GI pipes

270

-

737.01

... More
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. this include insertion of different dia DWC pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

200

-

1763.68

... More
Placing of DWC/RCC/GI pipes along with collars in trenches at places of track and road crossings, platform cuttings etc.

200

-

43.98

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)

100

-

31.85

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

100

-

286.62

... More
Laying of S&T Cables of various cores/ pairs/ quads//HDPE duct in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

50000

-

13.65

... More
Digging of cable pit (min 2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.

1

-

18331.32

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50M and route diversion as per Drg. No 4014/00/CC4 or latest/ stone markers.

500

-

602.05

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

2000

-

3.03

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

200

-

18.2

... More
Apparatus Case

-

-

-

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

-

-

-

... More
Single Case as per Drg No SK 748 or CSTE/5074

12

-

10096.78

... More
Half Case as per Drg No SK 747or CSTE/5074 or SS Location

8

-

7708.31

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand.

-

-

-

... More
Single Case

12

-

1522.55

... More
Half Case

8

-

928.09

... More
Fabrication and fixing of phenolic laminated sheet of size 10mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations Piano type switches and lamp holders should be ISI marked & as per instructions of Rly engineer at site.

-

-

-

... More
Single Case

12

-

3436.36

... More
Half Case

8

-

1002.4

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

15

-

5318.33

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

25

-

2917.72

... More
Installation of earth electrode as per std. practice and connecting it to equipments to be earthed. This item includes digging of pit in earth 3 m deep & fixing earth electrode pipe, casting of cement concrete enclosure & cover as per Drg No. S&T/Tender/27.Soil treatment to be done as per std. practice. This item includes provision of earth lead wires and soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. (Supply of earth electrode is covered in Sch. 'A').

70

-

2220.14

... More
Painting

-

-

-

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974).

-

-

-

... More
Apparatus Case Full Size. (Outside & inside)

12

-

371.54

... More
Apparatus case Half Size. (Outside & inside)

8

-

336.66

... More
Main Signal Post with Signal Units, Surface base and complete fittings as per Railways standard practice.

-

-

514.09

... More
Shunt signal post with signal unit, surface base as per Railway's Standard Practice.

18

-

321.5

... More
Track Lead Junction Box. (Black enamel outside only)

-

-

87.96

... More
Point Machine with ground connections complete (Point Machine with Black enamel only outside and ground connections with Red Oxide)

16

-

156.2

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make.

-

-

-

... More
Full Case.

12

-

175.91

... More
Half Case

8

-

119.8

... More
Telecomunication

-

-

-

... More
Testing and commissioning of complete OFC system equipments including outdoor work related to laying of Quad/PIJF cable, Emergency control, control office HD Crs & way stn. Equipments. This includes carring out various optical and other measurements required for healthy functioning of link and meeting various specification such as BER, jitter etc as per CCITT/F 801/821 and REC/ G921. Testing and commissioning of link should be done with site engineer. All measuring instruments required for this activity should be arranged by the contractor. This item also includes designing of complete system as per the present and future requirements .

1

-

372706.95

... More
Construction of Manholes below 300mm ground level each at every SJC with all contractor's material including the cover over the manhole dimension of the manhole pit shall be as per Drg. No. SK/CSTE/C/97/11

2

-

4459.35

... More
Installation of FMS with all installation material, splicing, termination of OF cable (with all contractor's tools & materials)

2

-

13189.05

... More
Installation, testing & commissioning of 25 watt VHF set in ASM room including errection of antenna at sufficent height on the roof of pannel building to have satisfactory communication. This includes GI mast with stand to adjust the height duly grouted and concreting on roof and supported by rope wire as decided by the site Engineer in-Charge

1

-

9833.25

... More
Laying of OFC cable in HDPE duct, as per approved cable roue plan in the excavated trench, taking due care while transporting. Laying of the cable also includes pulling of OFC cable, inside the existing stn. bldg & making suitable loop without cutting of cable at the entry/exit of the cable & inside the stn. bldg. wherever required. Cable to be protected with DWC pipe & with suitable clamping arrangements.

-

-

-

... More
Laying of OFC in HDPE Duct with Blowing technology

10

-

17127.6

... More
Training of IPRCL/ Railway officials in system installation, testing & handing the system equipments

2

-

13782.3

... More
LC Gate

-

-

-

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc.

-

-

59294.55

... More
Installation & commissioning of LC gate communication system between LC gate & Station. The connectivity of the master phone as well as Gate phone shall be as per instruction of Engineer in-charge. The indoor wiring for Master phone as well as Gate phone to be done through proper wiring material like PVC casing-capping of appropriate size etc.

-

-

1120.35

... More
Dismantling & maintenance

-

-

-

... More
Dismantling of the following

-

-

-

... More
Signal posts/BSLB/SLB/Stop board

-

-

243.6

... More
Steel apparatus case with fittings

-

-

243.6

... More
TLJB/Point JB

-

-

6300

... More
Signal Foundation (up to ground level by hydaulic breaker)

-

-

2282.7

... More
Maintenance of signalling system by providing manpower, vehicle, tools & plant and consumable as per guidelines of IPRCL/SECL after commissioning of the Manikpur S&T System.

3

-

737006.05

... More
Total Execution Outdoor(Schedule C TO K)

-

-

-

... More
Drawing

-

-

-

... More
Design of SIP & submission of three paper copies for approval and preparation of miniature plan also

-

-

-

... More
For a six- line station or more

1

-

78272.96

... More
Design of SWRD &submission of three paper copies for approval

-

-

-

... More
For a five - line station or more

1

-

31503.32

... More
Design of RCC & submission of three paper copies for approval

-

-

-

... More
For a five - line station or more

1

-

30626.67

... More
Design of cable Route Plan (Distant to Distant) & submission of three paper copies for approval.

-

-

-

... More
For a five - line station or more

1

-

21001.37

... More
Design of cable Route Plan (Mid Section) & submission of three paper copies for approval.

-

-

-

... More
For a six - line station or more

1

-

37713.52

... More
Design of Cable Distribution Plan & submission of three paper copies for approval.

-

-

-

... More
For a five - line station or more

1

-

14876.28

... More
Design of Circuit Diagrams consisting of the items as mentioned below & submission of three paper copies for approval (i) Wiring Diagrams (ii)Relay Disposition Charts (iii) Contact analysis and fuse particulars (iv) panel termination chart (v)CT rack particulars (vi) Input & output bit chart for EI systems.

-

-

-

... More
For a five - line station or more

1

-

166261.44

... More
Design of Miscellaneous Diagrams consisting of the items as mentioned below & submission of Three paper copies for approval (i) Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room etc. (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram

-

-

-

... More
For a five - line station or more

1

-

6125.08

... More
Design of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval

-

-

-

... More
For a five - line station or more

1

-

2187.8

... More
Design of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) and submission of Three paper copies for approval

-

-

-

... More
For a Five-Line Station or more

1

-

4375.6

... More
Supply of Original Tracing of SIP after incorporating all the corrections.

-

-

-

... More
For a Six-Line Station or more

1

-

884.27

... More
Supply of Original Tracing of SWRD after incorporating all the corrections.

-

-

-

... More
For a Five-Line Station or more

1

-

612.38

... More
Supply of Original Tracing of RCC after incorporating all the corrections.

-

-

-

... More
For a Five-Line Station or more

1

-

787.71

... More
Supply of Original Tracing of Cable Route Plan (Distant to Distant) after incorporating all the corrections.

-

-

-

... More
For a Five-Line Station or more

1

-

1575.42

... More
Supply of Original Tracing of Cable Route Plan (Mid Section) after incorporating all the corrections.

-

-

-

... More
For a Six-Line Station or more

1

-

1788.86

... More
Supply of Original Tracing of Cable Distribution Plan after incorporating all the corrections.

-

-

-

... More
For a Five-Line Station or more

1

-

1575.42

... More
Supply of Original Tracing of Circuit Diagrams consisting of the items as mentioned below after incorporating all the corrections. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems

-

-

-

... More
For a Five-Line Station or more

1

-

29401.91

... More
Supply of Original Tracing of Miscellaneous Diagrams consisting of the items as mentioned below after incorporating all the corrections. (i) Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram

-

-

-

... More
For a Five-Line Station or more

1

-

3063.18

... More
Supply of Original Tracing of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) after incorporating all the corrections.

-

-

-

... More
For a Five-Line Station or more

1

-

3063.18

... More
Supply of Original Tracing of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) after incorporating all the corrections.

-

-

-

... More
For a Five-Line Station or more

1

-

4812.65

... More
Supply of Amonia Print of Approved SIP .

-

-

-

... More
For a Five-Line Station or more

6

-

44.47

... More
Supply of Amonia Print of Approved SWRD.

-

-

-

... More
For a Five-Line Station or more

6

-

44.47

... More
Supply of Amonia Print of Approved RCC.

-

-

-

... More
For a Five-Line Station or more

6

-

44.47

... More
Supply of Amonia Print of Approved Cable Route Plan(Distant to Distant).

-

-

-

... More
For a Five-Line Station or more

6

-

44.47

... More
Supply of Amonia Print of Approved Cable Route Plan(Mid Section).

-

-

-

... More
For a Six-Line Station or more

6

-

47.01

... More
Supply of Amonia Print of Approved Cable Distribution Plan.

-

-

-

... More
For a Five-Line Station or more

6

-

44.47

... More
Supply of Amonia Print of Approved Circuit Diagrams consisting of the items as mentioned below. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars

-

-

-

... More
For a Five-Line Station or more

6

-

5249.71

... More
Supply of Amonia Print of Approved Miscellaneous Diagrams consisting of the items as mentioned below. (i) Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram

-

-

-

... More
For a Five-Line Station or more

6

-

438.32

... More
Supply of Amonia Print of Approved Location Box Drawings (Including Contact Analysis, Fuse Particulars etc).

-

-

-

... More
For a Five-Line Station or more

6

-

438.32

... More
Supply of Amonia Print of Approved Goomty Drawings ((Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc).

-

-

-

... More
For a Five-Line Station or more

6

-

874.1

... More
Supply of eight sets of Amonia Print of Approved Completion SIP .

-

-

-

... More
For a Five-Line Station or more

6

-

350.66

... More
Supply of eight sets of Amonia Print of Approved Completion SWRD.

-

-

-

... More
For a Five-Line Station or more

6

-

350.66

... More
Supply of eight sets of Amonia Print of Approved Completion RCC.

-

-

-

... More
For a Five-Line Station or more

6

-

350.66

... More
Supply of eight sets of Amonia Print of Approved Completion Cable Route Plan(Distant to Distant).

-

-

-

... More
For a Five-Line Station or more

6

-

350.66

... More
Supply of eight sets of Amonia Print of Approved Completion Cable Route Plan(Mid Section).

-

-

-

... More
For a Six-Line Station or more

6

-

372.26

... More
Supply of eight sets of Amonia Print of Approved Completion Cable Distribution Plan.

-

-

-

... More
For a Five-Line Station or more

6

-

350.66

... More
Supply of Eight sets of Amonia Print of Approved Completion Circuit Diagrams consisting of the items as mentioned below. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems

-

-

-

... More
For a Five-Line Station or more

6

-

42002.73

... More
Supply of Eight sets of Amonia Print of Approved Completion Miscellaneous Diagrams consisting of the items as mentioned below. (i) Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room etc (ii) Power Supply Diagrams along with power supply calculation. (iii ) Earthing Diagram

-

-

-

... More
For a Five-Line Station or more

6

-

3500.23

... More
Supply of Eight sets of Amonia Print of Approved Completion Location Box Drawings (Including Contact Analysis, Fuse Particulars etc).

-

-

-

... More
For a Five-Line Station or more

6

-

3500.23

... More
Supply of Eight sets of Amonia Print of Approved Completion Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc).

-

-

-

... More
For a Five-Line Station or more

6

-

7000.46

... More
Any other drawings required for execution purpose beyond the above has to be prepared and approved by competent authority and no extra payment will be made for the same.

-

-

-

... More
TOTAL Drawing (Schedule L)

-

-

-

... More
Total S&T Cost Of Execution

-

-

-

... More
Grand Total (Supply +Execution)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.