India Tourism Development Corporation Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
India Tourism Development Corporation Limited - ITDC Tender
Security and Emergency Services
Eprocure
Opening Date10 Oct 2024
Closing Date21 Oct 2024
Tender Amount₹ 16,34,240
Costs
EMD
₹ 32,700Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ITDC_210883_1Tender No
Engg/EM/CCTV/HKA/24Tender Authority
India Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://http://itdc.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supplying, Installation, Testing and Commissioning of CCTV System at Hotel Kalinga Ashok, Bhubaneswar.
Supplying, Installation, Testing and Commissioning of CCTV System at Hotel Kalinga Ashok, Bhubaneswar.
Supplying, Installation, Testing and Commissioning of CCTV System at Hotel Kalinga Ashok, Bhubaneswar.
BOQ Items
Supply, Installation, Testing & Commissioning of 32 Channel NVR which support up to 32 IP Camera , 8 SATA HDD ( Each up to 8TB) ,2 RJ45 10M/100M/1000M network Interface ,32CH 8HDD NVR ,Simultaneous HDMI & VGA up to 4K output, User-friendly GUI/WEB/Client ,1CH Audio IN and 1CH Audio Out ,16CH Alarm IN and 4CH Alarm Out ,AUDIO Parameters, Compression : H.265+ / H.265 / H.264, Record rate: 320Mbps, Bit Rate: 100Kbps ~ 8Mbps Per Channel, Record Mode: Manual, Schedule (Regular, Continuous), Motion Detection, Video Loss, Camera Tamper, Alarm in, Network Function: HTTP, HTTPS, TCP/IP, IPv4, UPnP, UDP, RTSP, SMTP, NTP, DNS, DHCP, P2P, IP Filter, DDNS,802.1X, SNMP & EN / CE / FCC / RoHS / BIS complete at site as per Direction of Engineer In charge.
2
-
-
Supply, Installation, Testing & Commissioning of 6TB Surveillance HDD complete at site as per Direction of Engineer In charge.
8
-
-
Supplying and Laying of UTP 4 Pair CAT 6 LAN Cable in the Existing surface/ recessed steel/ PVC conduit with connection Complete as Required as Direction of Engineer In charge.
1000
-
-
Supply, Installation, Testing & Commissioning of armored 06 Core Single mode (OS2) 9/125 Fiber Cable, ITU G.652.D, G.657A1, Outdoor Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel wire embedded in side sheathing as strengthening member for switch connectivity. Cable should be ROHS compliant and as per ANSI/TIA-568.3-D, Telcordia GR-20, IEC 60794-2/60794-3-10, ISO/IEC 11801, ISO/IEC 24702 complete on surface / recess / in existing pipe / open duct complete etc. complete at site as per Direction of Engineer In charge.
300
-
-
Wiring of circuit/ sub main wiring along with 2x1.5 wire size of FRLS PVC insulated copper conductor, single core cable in surface /Recessed medium existing PVC conduit complete at site as per Direction of Engineer In charge.
500
-
-
Wiring of circuit/ sub main wiring along with 4x1.5 wire size of FRLS PVC insulated copper conductor, single core cable in surface /Recessed medium existing PVC conduit complete at site as per Direction of Engineer In charge.
150
-
-
SITC of 12 Port LIU Complete as required as Direction of Engineer In charge.
2
-
-
Supply, Installation, Testing & Commissioning of LC-LC 9/125μm OS2 Single mode Round Cord duplex, LSZH fiber patch cord having a protective layer of metal braiding for LIU to switch connectivity. Patch Cord should have Blue Jacket with 1000 time mating cycle complete at site as per Direction of Engineer In charge.
4
-
-
Supplying and Fixing of 25 mm size of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit complete at site as per Direction of Engineer In charge.
20
-
-
Supplying and Fixing of 25 mm size, medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit complete at site as per Direction of Engineer In charge.
1000
-
-
SITC of Network Switch Managed Layer 2, 8 Port POE with 120 or above watt POE Budget with 2 SFP Port Loaded with minimum 1 SFP as per requirement complete as Direction of Engineer.
3
-
-
Supply, Installation, Testing & Commissioning of 24 Port POE Access Switches with switching capacity of min 56 Gbps, forwarding performance min 41 Mpps, having 24 x 10/100/1000BASE-T PoE (RJ45) with minimum PoE budget of 180W, with 4 x 1G SFP uplink ports. Operating temperature: 0°C to 45°C, complete at site as per Direction of Engineer In charge.
2
-
-
S.I.T.C of Wall Mount Network Racks 9U with accessories like FAN, PDU, Over Point, Cable manager etc. as per requirement, complete at site as Section of Engineer In charge
2
-
-
S.I.T.C Media Converter for Camera as per requirement, complete at site as Section of Engineer In charge
4
-
-
S.I.T.C of UHD LED smart TV with minimum requirements of screen Solution of 3840 X 2160 Pixel, sound output of 20 Watt, refresh rate 50 Screen Size 43", HDMI Port-2 nos., USB 2.0/3.0- 2 nos. with power Consumption of 0.5 W, AC 100-240 V, 50/60 HZ and with one year complete Warranty complete at site as per Direction of Engineer In charge.
2
-
-
Supply, Installation, Testing & Commissioning of Category 6 RJ45 Unshielded LSZH Patch Cord as per ANSI/TIA/EIA 568.2-D and ETL 04-Connector Channel Verified, ROHS Compliant, 24AWG Patch Cord, Diameter 5.8 ± 0.03 mm, 1 Meter, Operating Temperature -10 Deg C to +60 Deg C. patch cord 1 Mtr for Data at Rack Side for Switch to Jack Panel Connectivity complete etc as required for rack side switch to jack panel connectivity complete at site as per Direction of Engineer In charge..
50
-
-
Supply, Installation, Testing and commissioning of PTZ Camera Power Supply 12 volt/ 10 Amp. As per site requirements and Direction of Engineer Incharge.
2
-
-
Supply, Installation, Testing and commissioning of 5 Mtr HDMI Cable for connecting NVR to the screen complete at site as per Direction of Engineer In charge.
2
-
-
Supply, Installation, Testing & Commissioning of 15 U Wall Mount Rack with fans, stationary shelf, 6 Socket PDU, 2 Nos. of hardware pkts. As per site requirements and Direction of Engineer Incharge.
1
-
-
Supply, Installation, Testing and commissioning of PTZ Camera stand as per site requirements and Direction of Engineer Incharge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements