State Project Management Unit Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

State Project Management Unit Tender

Civil And Construction
Building Construction
Eprocure
Opening Date16 Jul 2022
Closing Date16 Aug 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Establishment Of Knowledge Centre At Walmi

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2. Excavation of foundation trenches and column foundation and pits of extra lift over the initial lift of 1.5 mtrs. but upto 7.50 mtr. Depth in all kind of soil as per direction of the Engineer-in-charge.

124

-

-

... More
3. Filling foundation trenches and plinths with excavated materials in layers not exceeding 0.3 mtr in depth including watering and ramming and dressing and levelling etc. complete as per the direction of the Engineer-in-charge.

499

-

-

... More
4. Filling in foundation trenches and plinths with filling sand, well watered, compacted, dressed and leveled to proper gradient etc., complete as per the direction of the Engineer-in-charge.

548

-

-

... More
5. Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 1 K.M initial lead, for all leads including all lifts involved.

20

-

-

... More
6. Anti-termite Treatment: Supplying, diluting and and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc. complete.as per IS:6313/1981 (PART-II) and as per the direction of engineer-in-charge including all cost of materials labour, taxes etc. all complete.

940

-

-

... More
7. Providing and laying of P.C.C. of 1:4:8 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

145

-

-

... More
8. Plain cement concrete (1:2:4) in foundation and bottom layers of flooring using 12 mm size black hard crusher broken granite chips.

6.75

-

-

... More
9. R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hosting and laying etc. all complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Foundation (Column bases)

158

-

-

... More
b. Super structure (Ground floor)

136.3

-

-

... More
c. Super structure (First floor)

153

-

-

... More
10. Providing smooth centering & shuttering for R.C.C works including false works and dismentalling then after casting including cost of materials complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Foundations, footings, bases of columns etc. for mass concrete.

397.61

-

-

... More
b. Suspended floors, roofs, landings, balconies and access platform.

801.49

-

-

... More
c. Columns, beams, plinth beams, girders, bressumers and cantilevers, staircase

760.76

-

-

... More
d. Lintels

53.51

-

-

... More
11. Providing M.S reinforcement for R.C.C work including cutting, bending, and tying the grlls and placing in position including cost of binding wire 18 to 22 gauge etc. complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Foundation plinth & Ground floor

353.16

-

-

... More
b. First floor

175.95

-

-

... More
12. Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in foundation & plinth as per the direction of the Engineer-in-charge .

55

-

-

... More
13. Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in Super structure as per the direction of the Engineer-in-charge .

-

-

-

... More
a. Ground floor

128.06

-

-

... More
b. First floor

124.68

-

-

... More
14. Reinforced Brick work with Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:4) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in Super structure as per the direction of the Engineer-in-charge .

-

-

-

... More
a. Ground floor

11.24

-

-

... More
b. First floor

6.75

-

-

... More
15. Providing average 25 mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips as per the direction of the Engineer-in-charge.

455.7

-

-

... More
16. Providing gola 75 mm x 75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) all complete as per direction of Engineer-in-charge. In 75 mm x 75 mm deep chase.

255.8

-

-

... More
17. Providing Avg. 12 mm thick cement plaster 1:4 (1 cement : 4 sand) to inside surface etc. as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Ground floor

639.75

-

-

... More
b. First floor

733.17

-

-

... More
18. Providing Avg. 16 mm thick cement plaster 1:6 (1 cement : 6 sand) to outside surface etc. as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Ground floor

639.75

-

-

... More
b. First floor

733.17

-

-

... More
19. Providing average 6 mm thick cement plaster(1:4) to R.C.C surfaces finished smooth including deep chipping & slurring treatment etc. complete.as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Ground floor

303.67

-

-

... More
b. First floor

220.05

-

-

... More
20. Providing & applying cement punning over cement plaster.

150

-

-

... More
21. Providing plaster drip course/ groove in plastered surface or moulding to R.C.C.projections. of size 40 mm x 12 mm deep in cement mortar proportion 1 : 3.

211.8

-

-

... More
22. Supplying 150 mm wide Chicken wire mesh of standard quantity as availbale in local market & fixing with U nails 150 mm center to center before plastering the junction of walls and beam/column in one vertical plane to prevent surface cracks appearing between junctions of column / beam and walls before plastering. Payment shall be made by measuring the chicken wire mesh.

125.48

-

-

... More
23. Providing and fixing circular / hexagonal M.S. sheet ceiling fan box 73 mm height make out of 1.5 mm thick M.S. sheet welded with 12 mm dia M.S. bar bent to shape with provision of conduit inlet all complete as per direction of Engineer-in-charge. The box shall be finished with two coats of anticorosive paints.

21

-

-

... More
24. Providing and applying 2 coats with 100% acrylic emulsion paint (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete.

-

-

-

... More
a. Ground floor

639.75

-

-

... More
b. First floor

733.17

-

-

... More
25. Supplying and painting of internal walls and ceiling with two or more coats of acrylic emulsion paint which includes two coat of internal putty with a coat of primer all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Ground floor

1232.04

-

-

... More
b. First floor

937.45

-

-

... More
26. Synthetic enamel painting two coats over one coat of primer on wood surface. etc.,complete as per the direction of the Engineer-in-charge.

179.52

-

-

... More
27. Plinth Protection Work: Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.

104.21

-

-

... More
28. STAINLESS STEEL STAIRCASE RAILING WITH HANDLE: Supplying , fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90mtr.C/C and stainless steel squara pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design & specification, buffing, polishing etc with cost of conveyance, taxes of all materials , labour, T & P etc. required for the complete in all respect as per the direction of Engineer-in-charge.

21.62

-

-

... More
FLOORING

-

-

-

... More
29. Fixing Chequered tile in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades on the tiles etc. complete as per direction of engineer in charge.

78

-

-

... More
30. Fixing vitrified tile or rustic vitrified tile (600mm x 600mm) in floors treads or steps and landing on 25mm thick bed of cement mortar 1 :4 (1 cement : 4 sand ) jointed with neat cement slurry mixed with pigment to match the shades on the tiles etc. complete as per direction of engineer in charge.

-

-

-

... More
a. Ground floor

325.7

-

-

... More
b. First floor

195.7

-

-

... More
31. Fixing vitrified tiles (600mm x 600mm) in dados skirting and risers of step on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades on the tiles etc. complete as per direction of engineer in charge.

-

-

-

... More
a. Ground floor

32.83

-

-

... More
b. First floor

17.33

-

-

... More
32. Providing and fixing 1st quality ceramic glazed wall tiles of approved make of 5mm and size 450 mm X 300 mm conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,including pointing in white cement mixed with pigment of matching shade complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Ground floor

132

-

-

... More
b. First floor

132

-

-

... More
33. Providing 18 mm thick approved quality & shade polished granite slabs, and cutting to required size laid over 20 mm thick under layer of cement mortar (1:3) to masonry or concrete surfaces in skirting, dado, risers and treads of steps, counters, edtges / facias complete (screwing on vertical surfaces if required) to proper level and joints filled with cement mixed with oxide matching colour in required proportion, washed, acid cleaned, including cost of all materials, labour, conveyance, taxes, royalties, scafflding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge.

56.11

-

-

... More
34. Supplying and fixing of W.I. clamps 25 cm to 30 cm long of 35mm x 5mm size for doors including fixing in C.C. 1:3:6 with 12mm to 20mm hard stone chips or in cement mortar 1:3 including cost of all materials.

168

-

-

... More
35. Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,rounding the edges, making and finishing the outlet complete.

8

-

-

... More
36. Supplying, fitting & fixing 100 mm dia p.v.c rain water pipe (medium) with necessary bends , shoes, heads, etc. including cost of P.V.C pipe, clamps, nails etc. complete.

80

-

-

... More
DOOR & WINDOW:

-

-

-

... More
37. Providing fitting, fixing of Al. door and ventilator with Al. choukath having Anodized Al. door choukath section no. 9205 & shutter section of 9219 as vertical member and top member, 9232 as bottom & middle member including fixing of 6mm plain glass in ventilator 8mm thick plain glass in shutter as panels of door frame by means of tapered clip no. 4660 and the to be completed by means of jointing angle no. 1855 including fixing 6 no.s of 4" aluminium heavy hinges , 4 no.s aluminium decorative handles , 2 no.s 250mm x 10mm aluminium tower bolt , 2 no.s of godrej make floor spring of model nom 3873, 1 no. of godrej make 6 lever mortice lock of approved model with cost of all material, cost of all fixture, cost of all labour, T&P , hire charges of drilling machine etc. complete.

40

-

-

... More
38. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory window s & other Frames/Chowkhat including 2 coats of Enamel paint and one coat of wood primer fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge) , minimum compressive strength of 58 N/mm2, modulus of elast icity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with m.s hold fast/ lugs/ SS dash fastner of required dia & length complete as per the direction of Engineer-in-charge. Frame size 50 x 125 mm.

72.3

-

-

... More
39. Providing and fixing 30 mm thick factory made single extruded WPC (Wood polymer composite) solid plain flush door shutter of required size fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, including all fittings etc. all complete as per direction of engineer in charge.

25

-

-

... More
40. U-PVC SLIDING WINDOW: Providing and fixing of factory made approved make uPVC 2-track/3-track Sliding window (Pearl White Colour) complete, comprising uPVC multi-chambered frame of size 67mm x 54mm having uPVC roller track on top and uPVC sash of size 64mm x 47mm duly reinforced with G.I. section 1.2 mm (+/- 0.2mm), wherever required. All corners of frame and sash will be fusion welded. After placing 6mm Clear Toughened glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush will be provided including hardware, i.e., touch lock and rollers & proper drainage system shall be provided. selicon sealent shall be provided out side and inside. window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.

104

-

-

... More
41. U-PVC LOUVER WINDOW (ADJUSTABLE): Providing and fixing of factory made approved make uPVC Louver window (Pearl White colour) comprising of uPVC multi-chambered frame of size 50 mm x 42 mm, duly reinforced with 1.2 mm (+/- 0.2 ) thick G. I. Section. Both vertical sides of the frame, adjustable louver with 4 mm frosted glass and having one lever to adjust the glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.

6

-

-

... More
42. Supplying, fabricating and fixing MS grills, railing and M.S frame madeup with M.S. square bar / round bar / flat / plate as per design and drawing including applying two coat enamel paint over a coat of red oxide primer and fixing the same to wooden door and window frames as per requirement and direction of Engineer-in-charge.

2860

-

-

... More
43. Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.

737

-

-

... More
44. STRUCTURAL GLAZING WORK: Supplying all labour, material for fabrication and installation of structural glazing work at specified places using colour anodized extruded aluminium sections (Approx. dimension) (Mullion 111 mm x 50 mm x 1.85 mm, transume - 56 mmx 50 mm x 1.80 mm sub frame - 20 mm x 12 mm x 2 mm) with 15-18 micorns anodize in desired coloured shade and 6 mm thick colour reflective toughened glass (approved size) which will be fixed with the sub frame using rubber gasket and structural sillicon sealant DC-995. The glass panel shall be fixed to mullion and transem sections as per the design provided in the drawing by maintaining a gap of 10-12 mm between two adjacent panels. The structural members shall be framed as per design and fixed to the R.C.C. member using stainless steel rowl plugs and steel screws. The job is inclusive of providing all materials, fabrication, erection and filling of all gaps upto 12 mm by using weather sealant and gap upto 100 mm using colour anodized aluminum sheet all complete as per direction of Engineer-in-charge. The design of structural glazing shall be done to resist 200 km / hr wind speed and should be tested before filling and a certificate from Govt. / Semi Govt. or Govt. authorised lab should be produced before fixing. The specification for accessories: (i) M.S. brackets - Galvanised M.S. brackets. (ii) Anchor fastners- approved make. (iii) Buts / nuts / washers- Stainless steel. (iv) Grouting fastners- P.V.C. bullet fastners. (v) Structural sealant- approved make. (vi) Foam spacer- approved make. (vii) Weather sealant - approved make. (viii) Gasket for glazing and water prevention- EPDM gasket. (ix) Provision for two point locking handles for top-hung openable shutters. (x) Other standard accessories which are the part as standard fabrication design.

87

-

-

... More
(B) INTERNAL P.H. WORKS

-

-

-

... More
45. Providing all materials, labour, T&P for laying/fixing of following dia CPVC pipes SDR-11 as per IS-15778/2007 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of transportation scaffolding etc. Including GST as per specification and direction of Engineer-in-charge. Make: Astral or equivalent.

-

-

-

... More
a. 15mm dia

5

-

-

... More
b. 20mm dia

10

-

-

... More
c. 25mm dia

30

-

-

... More
d. 32mm dia

20

-

-

... More
46. Providing all materials, labour, T&P for laying/ fixing of following dia uPVC solvent welded pipes Sch-80 as per ASTM-D-1785 including fixing of required size uPVC Schedule-80 fittings as per ASTM D-2467 like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of transportation, scaffolding etc. as per specification including GST and direction of Engineer-in-charge.

-

-

-

... More
a. 25mm dia

5

-

-

... More
b. 32 mm dia

5

-

-

... More
c. 40 mm dia

5

-

-

... More
d. 50 mm dia

25

-

-

... More
47. Providing all materials, labour, T&P for fitting & fixing of following CPVC Ball Valves (CTS Sockets) confirming to IS-15778 with ISI mark as per ASTM D-2846 in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of transportation scaffolding etc. all complete as per specification including GST and direction of Engineer-in-charge

-

-

-

... More
a. 25 mm dia CPVC ball valve

2

-

-

... More
b. 32 mm dia CPVC ball valve

2

-

-

... More
c. 40 mm dia CPVC ball valve

1

-

-

... More
d. 50 mm dia CPVC ball valve

1

-

-

... More
48. Supplying all materials, labour, T&P and fitting and fixing of CI water sluice valve / butterfly valves / air valves/ non return valve of the following sizes confirming to the relevant IS specification and dimension including fixing it in position along the pipeline with supply of all required materials such as rubber insertion, nuts & bolts including cost of all materials, taxes, and duties, transportation charges from store to site etc all complete as per the direction of Engineer-in-charge. 50 mm dia non return valve.

1

-

-

... More
49. Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of all materials, curing, conveyance of all materials etc. all complete including GST as per specification & direction of Engineer-in-charge.

2

-

-

... More
50. Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking pipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, duties etc. all complete as per specification including GST & direction of Engineer-in-charge. For 15mm to 50mm dia pipe to pass in 125mm to 250mm thick wall.

5

-

-

... More
51. Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china water closet (European pattern) 'P' or 'S' type of approved make as per IS-2556 with ISI mark in all floor including supply of sutaible PVC wall plug and Brass screws etc. all complete including cost of PVC seat cover (solid) with hinges & rubber buffers including testing etc. all complete with all cost, and conveyance as per specification all complete including GST as per direction of Engineer-in-charge. European Water closet With Cistern . Model no :Jaquar : CNS-WHT-959UF Wall Hung WC With UF Soft Close Seat Cover, Hinges, Accessories Set, Size: 370x540x410 mm WHC-WHT-184NL Wall Hung Cistern with 39mm Drainage L-Bend Pipe with Gasket & installation kit.

8

-

-

... More
52. Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous china flat back, lipped front urinal basin confirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from water supply pipe with transportation etc. all complete as per specification including GST & direction of the Engineer-in-charge. 610 x 410 x 380 mm size flat back large standing urinal. Model no: Jaquar: URS-WHT-13255 Urinal without sensor with Fixing, Accessories Set, Size: 480x300x740mm

12

-

-

... More
53. Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous china flat back, lipped front urinal basin confirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from water supply pipe with transportation etc. all complete as per specification including GST & direction of the Engineer-in-charge. 610 x 410 x 380 mm size flat back large standing urinal. Model no: Jaquar: URS-WHT-13255 Urinal without sensor with Fixing, Accessories Set, Size: 480x300x740mm.

4

-

-

... More
54. Supply all materials and labour for fitting and fixing of matrix set (Wash basin 46 x 36 with one pair mounting brackets,european water closet & cistern complete with fittings & seat cover, one no hinged rail 76 cm and 4 nos of grab rails 60 cm) including cutting the walls & floor and making good the damages with cement concrete etc. including transportation etc. all complete including GST as per direction of EIC.

2

-

-

... More
55. Providing all materials, labour, T&P for fixing of following sizes of bevelled edge mirror of 5mm thick mounted on 6mm thick AC back sheet & CP cup screw with PVC wall plugs in all floor including cost, conveyance, all materials complete as per specification including GST and direction of E.I.C. 600mm x 450mm size. Model no: Jaquar : AKP-35795 Swivel Mirror 630 X 445mm Rectangular Shape.

12

-

-

... More
56. Providing all materials, labour,T&P ,fittings and fixing of different water supply (CP on Brass) fitting (Quarter Turn or as specified) as per IS specification & approved make in all floor of following sizes and specification with leak proof threaded joints with thread seal tape or any other method as required and directed including transportation etc., testing and rectification of defects after testing complete including GST as per direction of Engineer-in-charge.

-

-

-

... More
a. 15mm dia Two-Way Bibcock with wall flange. Model no: Jaquar: FUS-29041

8

-

-

... More
b. 15mm dia Angle Stop cock with wall flange. Model no: Jaquar: FUS-29053

20

-

-

... More
c. 15mm dia Concealed Stop cock with wall flange. Model no: Jaquar: FUS-29083K & ALD-089.

4

-

-

... More
d. C.P. Soap Dish Holder. Model no: Jaquar: AHS-1531

8

-

-

... More
e. Health Faucet ABS SS braided hose 1.00m with CP hook. Model no: Jaquar : ALD-573

8

-

-

... More
f. 15mmx50mm C.P. Extension piece

4

-

-

... More
g. 15mm CP Spreader

4

-

-

... More
h. 32mm dia C.P. Dome Waste coupling (Full Threaded). Model no: Jaquar: ALD-705

12

-

-

... More
i. CP Grating.

20

-

-

... More
j. Towel Ring. Model no : Jaquar: ACN-1121BN

6

-

-

... More
k. Robe Hook. Model no : Jaquar : ACN-1191N

8

-

-

... More
l. 15mm dia CP Bib Cock with Wall Flange. Model no :Jaquar : FUS-29037

4

-

-

... More
m. Pillar cock. Model no: Jaquar: OPP-15001PM

12

-

-

... More
n. Urinal Auto flush cock. Model no :Jaquar : PRS-073

4

-

-

... More
o. Division plate for Urinal. Model no :Jaquar JSE-CHR-810US450X

2

-

-

... More
57. Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge.

-

-

-

... More
a. 5000 Litres Capacity for drinking work Polyethylene moulded water storage tank with lid & locking arrangement as per IS-12701/1996 with ISI mark.

1

-

-

... More
b. Supply, installation,testing & commisioning of fitting of Aquaguard water Storage Cooler-cum-Purifier with necessary water connection & waste arrengments with all labour, T&P etc.all complete as per the specification including GST & direction of EIC. Chilling Capacity upto 60 ltr/hr & Purification capacity 20 ltr.

1

-

-

... More
58. Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including transportation & scaffolding etc. all complete as per specification including GST & direction of the Engineer-in-charge. 110mm dia pipe.

60

-

-

... More
59. Supplying all materials, labour, T&P, fitting and fixing of following dia uPVC SWR (Co-moulded Ring type) fittings of approved make confirming to IS-14735 with ISI marked in all floor with transportation & requisite testing as per specification including GST & direction of EIC.

-

-

-

... More
a. 110mm x110mm P-Trap

8

-

-

... More
b. 110mmx87.5º Plane bend

8

-

-

... More
c. 110mmx87.5º door bend

8

-

-

... More
d. 110mmx45º Plane Bend

8

-

-

... More
e. 110mm dia single 'Y' withoutdoor

8

-

-

... More
f. 110mm WC connector/Bend with lip ring

8

-

-

... More
g. 110mm Socket plug

8

-

-

... More
h. 110mm Pushfit Coupler

8

-

-

... More
(C) EXTERNAL P.H. WORKS

-

-

-

... More
60. Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including transportation & scaffolding etc. all complete as per specification including GST & direction of the Engineer-in-charge. 150mm dia pipe.

20

-

-

... More
61. Gully trap (300 X 300 X 450)mm (Inside): Providing all material, labour, T&P and Constructing gully trap (Inner size 300mm x 300mm x 450mm depth ) with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design , foundation concrete (1:4:8), inside & outside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, brick work with flyash bricks having crushing strength not less than 75kg/cm² in cement mortar (1:4), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber complete as per specification.

3

-

-

... More
62. Inspection chamber ( 750 x 750 x 500 ) mm (Inside): Providing all material, labour, T&P and Constructing Inspection chamber (Inner size 750mm x 750mm x 500mm depth ) with RCC precast cover (1:1½:3) with 12mm size hg chips, foundation concrete (1:4:8), inside & outside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² in cement mortar (1:4), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber as per specification.

3

-

-

... More
63. Man hole ( 900 x 800 x 900 ) mm (Inside): Providing all materials, labour, T&P required for construction of R.C.C M-25 man hole of size 900mm x 800mm x 900mm depth (inside) including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, all side walls & roof slab shall be not less than 150mm, 150mm & 125mm (avg.) respectively. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all bracing, ties, anchorage & supports and removing the same after required paid & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality ,earthwork in excavation in all kinds of soil and refilling the cavity around the chamber as per specification.

1

-

-

... More
SEPTIC TANK: Size (5.5 x 2.0 x 2.5)m. (inside)

-

-

-

... More
64. Earth work in all kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.

36.5

-

-

... More
65. Excavation of foundation trenches and column foundation and pits of extra lift over the initial lift of 1.5 mtrs. but upto 3.0 mtr. Depth in all kind of soil as per direction of the Engineer-in-charge.

26.5

-

-

... More
66. Filling foundation trenches and plinths with excavated materials in layers not exceeding 0.3 mtr in depth including watering and ramming and dressing and levelling etc. complete as per the direction of the Engineer-in-charge.

21

-

-

... More
67. Filling in foundation trenches and plinths with filling sand, well watered, compacted, dressed and leveled to proper gradient etc., complete as per the direction of the Engineer-in-charge.

4.3

-

-

... More
68. Providing and laying of P.C.C. of 1:3:6 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

3.5

-

-

... More
69. R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hosting and laying with Centering & Shuttering etc. all complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. footing

5

-

-

... More
b. Wall

10.6

-

-

... More
c. slab

5

-

-

... More
70. Providing M.S reinforcement for R.C.C work including cutting, bending, and tying the grlls and placing in position including cost of binding wire 18 to 22 gauge etc. complete as per the direction of the Engineer-in-charge. Foundation plinth

22.66

-

-

... More
71. 20 mm thick inside surface cement plaster(1:4) with neat cement punning

54.2

-

-

... More
72. Providing Avg. 16 mm thick cement plaster 1:6 (1 cement : 6 sand) to outside surface etc., as per the direction of the Engineer-in-charge.

50.9

-

-

... More
73. Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar

10

-

-

... More
74. 40 mm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips for old work. in Ground Floor

15

-

-

... More
75. Providing and fixing in position RCC precast cover (1:1½:3) with 12mm size hg chips of cover 760mm diameter and 100mm thick with lifting arrangement to be provided over a clear opening of 560mm diameter in the manhole slab.

2

-

-

... More
76. Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B)(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including transportation & scaffolding etc. all complete as per specification including GST & direction of the Engineer-in-charge. Make: ASTRAL/ SUPREME/ ASHIRVAD

-

-

-

... More
a. 110mm dia pipe

2

-

-

... More
b. 150mm dia pipe (Inlet & Outlet pipe)

5

-

-

... More
c. 150 mm UPVC Tee

2

-

-

... More
d. 150 mm Elbow

2

-

-

... More
SOAK PIT: Size 2.0m dia. (Inside)

-

-

-

... More
77. Earth work in all kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.

9.2

-

-

... More
78. Excavation of foundation trenches and column foundation and pits of extra lift over the initial lift of 1.5 mtrs. but upto 3.0 mtr. Depth in all kind of soil as per direction of the Engineer-in-charge.

9.2

-

-

... More
79. Excavation of foundation trenches and column foundation and pits of extra lift over the initial lift of 3.0 mtrs. but upto 4.5 mtr. Depth in all kind of soil as per direction of the Engineer-in-charge.

3.1

-

-

... More
80. Filling foundation trenches and plinths with excavated materials in layers not exceeding 0.3 mtr in depth including watering and ramming and dressing and levelling etc. complete as per the direction of the Engineer-in-charge.

14.3

-

-

... More
81. Filling in foundation trenches and plinths with filling sand, well watered, compacted, dressed and leveled to proper gradient etc., complete as per the direction of the Engineer-in-charge.

2.5

-

-

... More
82. Providing and laying of P.C.C. of 1:3:6 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

0.1

-

-

... More
83. Fly ash Brick Masonry in Cement Mortar (1:4) using bricks of size (23 Cm. x 11 Cm. x 8Cm.) in foundation and plinth

6.5

-

-

... More
84. R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hosting and laying with Centering & Shuttering etc. all complete as per the direction of the Engineer-in-charge.

0.4

-

-

... More
85. Providing M.S reinforcement for R.C.C work including cutting, bending, and tying the grlls and placing in position including cost of binding wire 18 to 22 gauge etc. complete as per the direction of the Engineer-in-charge. Foundation plinth

0.4

-

-

... More
86. Providing Avg. 16 mm thick cement plaster 1:6 (1 cement : 6 sand) to outside surface etc., as per the direction of the Engineer-in-charge.

15.7

-

-

... More
87. Providing and fixing in position RCC precast cover (1:1½:3) with 12mm size hg chips of cover 760mm diameter and 100mm thick with lifting arrangement to be provided over a clear opening of 560mm diameter in the manhole slab.

1

-

-

... More
88. Providing and laying of brick khoa of size 40 to 50mm over the entire surface inside the soak pit to the full height compacted to a firm condition complete as per drawing.

7.9

-

-

... More
89. 40 mm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips for old work. in Ground Floor

4.9

-

-

... More
RECHARGE PIT: (1.2 x 1.2 x 2) Mtr. :

-

-

-

... More
90. Construction of Rain water harvesting System. Supply all materials,labour & T& P for construction of Rain Water Recharge Pits including collection of rain water by laying of SWR Type-A pipes, collection chamber from different source both from roof & inside the Premises etc. all complete in all respect including GST as per direction of Engineer-in-charge. Inner size 1.2 mtr x 1.2 mtr. 2.00 mtr depth

4

-

-

... More
91. Providing ,Supplying, fixing, testing uPVC , pipes & fittings conforming to ASTM-D-1785 (sch-80) of approved make.Jointing with solvent cement solution as per ASTM-D-2564t & testing of joints complete as per direction of the Engineer-in-charge

-

-

-

... More
a. 100 mm nominal dia pipes.

66.4

-

-

... More
b. 110mmx87.5º Plane bend

4

-

-

... More
c. 110mmx45º Plane Bend

4

-

-

... More
(D) ELECTRICAL WORKS:

-

-

-

... More
POINT & WIRING

-

-

-

... More
92. Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I box having modular base & cover plate of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.

-

-

-

... More
a. Angle Holder point

10

-

-

... More
b. Tube Light Point/ceiling light point

102

-

-

... More
c. Exhaust Fan point

10

-

-

... More
d. Ceiling Fan Points

21

-

-

... More
e. Calling bell Points

1

-

-

... More
93. Supplying and fixing of following modular type switch / socket on the existing switch box / cover including connections etc as required. 5/6 amp. Switch

23

-

-

... More
94. Supplying and fixing of following modular type switch / socket on the existing switch box / cover including connections etc as required. 3 pin 5 / 6 amp socket outlet.

23

-

-

... More
95. Supplying and fixing of modular G.I. box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface or inrecess with suitable size of modular base & cover plate in front including providing and fixing 3 pin 5 / 6 amps socket outlet and 5 / 6 amps modular type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings)

42

-

-

... More
96. Supplying and fixing of modular G.I. box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of modular base & cover plate in front including providing and fixing 5 pin 15 / 16 amps socket outlet and S.P. 15 / 16 amps modular type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings)

11

-

-

... More
97. Supplying and fixing batten holder/ BK angle holder ISI marked including connection etc. as required.

10

-

-

... More
98. Supply of fan regulator

21

-

-

... More
99. Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required

21

-

-

... More
100. Supply of all required materials and recessed wiring to circuit / sub-main with followings number and sizes of PVC insulated FRLS 1100 volt grade stranded copper wire run inside 20mm PVC conduit (14S.W.G) pipe laid on surface of wall / ceiling and copper wire as earth continuity conductor and comple in all respect including making good to all damages caused and as per instruction of Electrical Engineer - in - charge. All switches & ceiling roses are ISI marked.

-

-

-

... More
a. Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.

490

-

-

... More
b. Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.

525

-

-

... More
c. Recessed wiring to submain in 4 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)

75

-

-

... More
d. Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)

75

-

-

... More
101. Supply of 4 x25 sqmm Ar. Al. calbe

70

-

-

... More
102. Supply of 3x1/2x95 sqmm Ar. Al. calbe

50

-

-

... More
103. Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. Supply of 4 x25 sqmm Ar. Al. calbe

4

-

-

... More
104. Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. 3x1/2x95 sqmm Ar. Al. calbe

4

-

-

... More
105. Supplying and drawing following pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed steel / PVC conduit as required.

240

-

-

... More
106. Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required

70

-

-

... More
107. Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required

50

-

-

... More
108. Supply and fixing of tv cable RG-6 grade, 7mm solid conductor PE insulated shield with fine tined copper braid and protected with fr pvc sheath along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.

190

-

-

... More
109. Supplying and fixing of following sizes of PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. 20mm pvc conduit

460

-

-

... More
110. Supplying and fixing telephone socket outlet modular type ISI marked on the existing switch board / cover including connections etc as requird.

8

-

-

... More
111. Supplying and fixing T.V. antenna socket outlet modular type ISI marked on the existing switch board / cover including connections etc as requird.

7

-

-

... More
112. Supplying and fixing of 16 / 18 SWG metal box of following sizes (nominal size) on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.

36

-

-

... More
113. Supply, installation,testing and commissioning of boards consisting of 1 No 20-A DP Modular switch with indicator and 1 No 16A Moular socket in indivisual Modular G.I Box for control of AC points complete in all respect as per technical specification & direction of Engineer in Charge.

14

-

-

... More
EARTHING

-

-

-

... More
114(a). Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required

5

-

-

... More
114 (b). Supplying and laying 8 SWG copper wires ISI marked at 0.5 meter below grond level for conductor earth electrode including soldering. 8 No swg

140

-

-

... More
115. Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.

1

-

-

... More
116. Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

120

-

-

... More
117. Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

40

-

-

... More
118. Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.

1

-

-

... More
119. PANEL & DISTRIBUTION BOARD: Supply, delivery, installation, testing & commissioning of L.T indoor floor/wall mounted type distribution boards made out to 2mm thicks CR sheet metal cubicle fixed on m.s channel base, duly acid treated for derusting, primered and painted with 2 coats of power coating of approved shade, dust, damp& vermin proof; having hinged door and compartmental arrangment for eact equipment & busbar chamber on the top of the panel running horizontally having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant IS and as per special condition of contract making good the damages caused complete as per the direction of Electrical Engineer in charge .

-

-

-

... More
a. Main distribution board: Incomming: MAIN IN COMING, 200 AMP.F.P MCCB -01SET, 200 AMP.F.P.C.O - 1NO, Without meter space, Out going, 500 Amp, 25/3mm. Copper busbar-04 nos, Instruments, 32AMP TPN MCB -5 NOS., 63AMP TPN MCB -2 NOS., 0-300Amp ammeter with selector switch -01set, 200/5 Amp. CT. - 01 set, 0-500 Volt Voltmeter with selector switch -01 set, Indicating lamp with controlling switch -01set.

1

-

-

... More
b. Branch Distribution Board (Light) Company made, 4 way 3 phase DB-1, Incomming, 32 Amp TPN MCB -1 No, Out going, 10A -12 nos.

2

-

-

... More
c. Branch Distribution Board (Power)Company made, 6 way 3 phase DB-1, Incomming, 63 Amp TPN MCB -1 No. Out going, 25A -18 nos

2

-

-

... More
d. Out door light distribution board: Incomming: MAIN IN COMING, 40 AMP. TPN mcb -01SET, Contactor with Timer, Out going, 63 Amp, 25/3mm. Copper busbar-04 nos, Instruments, 32AMP DP MCB -8 NOS., Indicating lamp with controlling switch -01set.

1

-

-

... More
120. FITTING & FIXTURES: Supply, delivery, installation , testing and commissioning of the followig fittings / fixtures complte will all required accessories and lamps on wall / ceiling as per the direction of Electrical Engineer in Charge

-

-

-

... More
a. Indoor decorative luminaire for Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver for LED tube light fitting Philips/Havells Catalogue No. ENDURALINEARNE OBS20WLED865SPCWH diffused for 20w LED and complete with all other accessories making good in all respect with complete testing as per direction of Engineer in charge.

18

-

-

... More
b. Indoor decorative luminaire for Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver for LED tube light fitting Philips/Havells Catalogue No. DURABS40WLED865SPCSS diffused for 40w LED and complete with all other accessories making good in all respect with complete testing as per direction of Engineer in charge.

10

-

-

... More
c. Indoor decorative luminaire for Surface Environmental friendly,Surface/pendant downlight with white/black powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency Philips/Havells Catalogue .CYLINDROPROSURFDLS15WLED857S45DBLK LED and complete with all other accessories making good in all respect with complete testing as per direction of Engineer in charge.portico

6

-

-

... More
d. Providing and fixing of 1 x 10 W LED Philips/Havells make Cat. No. LHLDERUEMD8X010 with testing and complete with all accessories as per the direction of Engineer in charge.

8

-

-

... More
e. Surface mounted light Philips/ Havells make Cat. No. INTEGRANEOSURFA CEDLS15WLED840S and complete with all other accessories including fixing and making good in all respect with complete testing as per direction of Engineer in charge.

48

-

-

... More
f. Indoor decorative luminaire for Surface and wall mounted light fitting Philips/Havells Catalogue No. Floretine WL 1LS B22 SS diffused for 9w LED and complete with all other accessories making good in all respect with complete testing as per direction of Engineer in charge.

4

-

-

... More
g. Supply, delivery, installation , testing and commissioning of Indoor luminaire for recessed mounted LED 2X2 ultra morden with high brightness SMD LEDS as light source,(Havells Catalogue No. PLUTONEO 2X2PLR34WLED840S or equivalent from approved make list) 34w complete with all other accessories & in all respect with complete testing as per direction of Engineer in charge.

10

-

-

... More
121. Supply, delivery, installation and testing of following sweeps of energysaving star rating a.c. ceiling fan complete with fan blades, down rod, canopies, capacitor etc including supply of sundry materials, making connection froom the suitable point outlet but excluding cost of fan regulator complete as per Electrical Engineer in charge. 1200 mm sweep ceiling fan Panasonic cat.no.- Cool king.

21

-

-

... More
122. Supply, delivery, installation & testing of following sweeps and speed of exhaust fans suitable for operational at 250 volt, 50 hz a.c. supply complete with a set of propeller blade, tripod leg for mounting of motor, ring frame, blades, gravity louvre complete assembly including supply of sundry materials, making hole of suitable size for housing of exhaust fan, making connection from suitable point outlet, making good the damages caused complete as per Electrical Engineer in charge. 250 mm sweep 900 rpm Panasonic cat.no.Smartair Ventilation Fan.

8

-

-

... More
(E). EXTERNAL DEVELOPMENT WORKS:

-

-

-

... More
C.C ROAD (6.0 Mtr. Wide)

-

-

-

... More
123. Loosening of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of table 300-2 for sub-grade construction & Clause 305 of MoSRT&H Specifications for Road & Bridge works (4th Revision).

105

-

-

... More
124. Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision)

48.75

-

-

... More
125. Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .

45

-

-

... More
126. Providing and laying of P.C.C. of 1:4:8 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

45

-

-

... More
127. Providing and fixing 25mm thick compressible fibre board in expansion joint on road after each 6mtr. Interval crosswise including cost of all materials labour, T&P etc. complete as per specification and direction of Engineer-in-charge.

50

-

-

... More
GATE

-

-

-

... More
128. Earth work in all kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.

35

-

-

... More
129. Filling foundation trenches and plinths with excavated materials in layers not exceeding 0.3 mtr in depth including watering and ramming and dressing and levelling etc. complete as per the direction of the Engineer-in-charge.

22

-

-

... More
130. Filling in foundation trenches and plinths with filling sand, well watered, compacted, dressed and leveled to proper gradient etc., complete as per the direction of the Engineer-in-charge.

4.36

-

-

... More
131. Providing and laying of P.C.C. of 1:4:8 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

3.6

-

-

... More
132. R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hosting and laying with Centering & Shuttering etc. all complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Foundation (Column bases)

2.5

-

-

... More
b. Column & beam

3

-

-

... More
c. Roof slab

1.5

-

-

... More
133. Providing M.S reinforcement for R.C.C work including cutting, bending, and tying the grlls and placing in position including cost of binding wire 18 to 22 gauge etc. complete as per the direction of the Engineer-in-charge. Foundation plinth & Ground floor.

7.7

-

-

... More
134. Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in foundation & plinth as per the direction of the Engineer-in-charge .

4

-

-

... More
135. Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in Super structure as per the direction of the Engineer-in-charge .

18

-

-

... More
136. Providing Avg. 16 mm thick cement plaster 1:6 (1 cement : 6 sand) to outside surface etc. as per the direction of the Engineer-in-charge.

194

-

-

... More
137. Providing and applying 2 coats with 100% acrylic emulsion paint (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete.

194

-

-

... More
138. Providing, fixing, fabricating and erecting mild steel gate (Size of Main Gate (Double Leaf): 1.8m x 2.4m (2Nos.) of standard steel hollow section, M.S angle, M.S.flat, M.S.plate, M.S.bar, as per detailed drawing including all standard fixtures such as hold fast, washers, M.S.rod, locking arrangement, handles, stoppers, gusset plate,T-bolt 250mm long ,roller and guides needed on edge of the two leaf and erected in all respect including transportation, cutting, operation involved with plate connectors, pinion joints etc.,rate to include one coat primer and three coats of enamel paint to give smooth and even surface as per direction of Engg.Incharge. (All steel hollowsection, M.S angle, M.S. flat, M.S. plate, M.S bars, etc. should be as per IS 4923 / IS 2062 to be followed).

2

-

-

... More
139. Providing,fixing,fabricating and erecting mild steel wicket gate:0.9m x 1.5m(1Nos.) of standard steel hollow section,M.S angle, M.S.flat, M.S.plate, M.S.bar,as per detailed drawing including all standard fixturessuchasholdfast, washers, M.S.rod, locking arrangement, handles, stoppers, gusset plate,T-bolt 250mm long ,roller and guides needed on edge of the single leaf and erected in all respect including transportation,cutting,operation involved with plate connectors,pinion joints etc.,rate to include one coat primer and three coats of enamel paint to give smooth and even surface as per direction of Engg.Incharge. (All steel hollowsection, M.S angle, M.S. flat, M.S. plate, M.S bars, etc. should be as per IS 4923 / IS 2062 to be followed).

0.75

-

-

... More
SECURITY SHED (3M. X 3.6M.)

-

-

-

... More
140. Earth work in all kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing not exceeding 0.3m in depth and the earth transported by transport vehicles as directed by the Engineer-in-charge.

20

-

-

... More
141. Filling foundation trenches and plinths with excavated materials in layers not exceeding 0.3 mtr in depth including watering and ramming and dressing and levelling etc. complete as per the direction of the Engineer-in-charge.

6.5

-

-

... More
142. Filling in foundation trenches and plinths with filling sand, well watered, compacted, dressed and leveled to proper gradient etc., complete as per the direction of the Engineer-in-charge.

4

-

-

... More
143. Providing and laying of P.C.C. of 1:4:8 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

3.5

-

-

... More
144. Plain cement concrete (1:2:4) in foundation and bottom layers of flooring using 12 mm size black hard crusher broken granite chips.

0.8

-

-

... More
145. R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hosting and laying etc. all complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Foundation (Column bases)

4

-

-

... More
b. Super structure (Ground floor)

8

-

-

... More
146. Providing smooth centering & shuttering for R.C.C works including false works and dismentalling then after casting including cost of materials complete as per the direction of the Engineer-in-charge.

-

-

-

... More
a. Foundations, footings, bases of columns etc. for mass concrete.

24

-

-

... More
b. Suspended floors, roofs, landings, balconies and access platform.

15

-

-

... More
c. Columns, beams, plinth beams, girders, bressumers and cantilevers, staircase

24

-

-

... More
147. Providing & laying 40mm thick damp-proof course to all masonry works as per specifications in 1:2:4 with 12.5 mm and crusher broken chips the DPC shall be laid in two layers of 20 mm thick each etc. complete as per specification, drawings and as directed by Engineer-in-charge.

3.3

-

-

... More
148. Providing M.S reinforcement for R.C.C work including cutting, bending, and tying the grlls and placing in position including cost of binding wire 18 to 22 gauge etc. complete as per the direction of the Engineer-in-charge. Foundation plinth & Ground floor

10

-

-

... More
149. Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in foundation & plinth as per the direction of the Engineer-in-charge .

5.2

-

-

... More
150. Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance ± 2 % in cement mortar (1:6) in 230 mm thick wall, immersing the bricks for minimum 6 hrs in water before use, in Super structure as per the direction of the Engineer-in-charge .

7

-

-

... More
151. Providing average 25 mm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips as per the direction of the Engineer-in-charge.

10.8

-

-

... More
152. Providing gola 75 mm x 75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) all complete as per direction of Engineer-in-charge. In 75 mm x 75 mm deep chase.

13.2

-

-

... More
153. Providing Avg. 12 mm thick cement plaster 1:4 (1 cement: 4 sand) to inside surface etc. as per the direction of the Engineer-in-charge. Ground floor

40

-

-

... More
154. Providing Avg. 16 mm thick cement plaster 1:6 (1 cement : 6 sand) to outside surface etc. as per the direction of the Engineer-in-charge. Ground floor

40

-

-

... More
155. Providing average 6 mm thick cement plaster(1:4) to R.C.C surfaces finished smooth including deep chipping & slurring treatment etc. complete.as per the direction of the Engineer-in-charge. Ground floor

10.8

-

-

... More
156. Providing and fixing circular / hexagonal M.S. sheet ceiling fan box 73 mm height make out of 1.5 mm thick M.S. sheet welded with 12 mm dia M.S. bar bent to shape with provision of conduit inlet all complete as per direction of Engineer-in-charge. The box shall be finished with two coats of anticorosive paints.

1

-

-

... More
157. Providing and applying 2 coats with 100% acrylic emulsion paint (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete.

40

-

-

... More
158. Supplying and painting of internal walls and ceiling with two or more coats of acrylic emulsion paint which includes two coat of internal putty with a coat of primer all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge.

50.8

-

-

... More
DOOR & WINDOW :

-

-

-

... More
159. Providing fitting, fixing of Al. door and ventilator with Al. choukath having Anodized Al. door choukath section no. 9205 & shutter section of 9219 as vertical member and top member, 9232 as bottom & middle member including fixing of 6mm plain glass in ventilator 8mm thick plain glass in shutter as panels of door frame by means of tapered clip no. 4660 and the to be completed by means of jointing angle no. 1855 including fixing 6 no.s of 4" aluminium heavy hinges , 4 no.s aluminium decorative handles , 2 no.s 250mm x 10mm aluminium tower bolt , 2 no.s of godrej make floor spring of model nom 3873, 1 no. of godrej make 6 lever mortice lock of approved model with cost of all material, cost of all fixture, cost of all labour, T&P , hire charges of drilling machine etc. complete.

2.61

-

-

... More
160. Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154, 151-155, as windows frame section No. 151- 155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge.

6.4

-

-

... More
161. Supplying, fabricating and fixing MS grills, railing and M.S frame madeup with M.S. square bar / round bar / flat / plate as per design and drawing including applying two coat enamel paint over a coat of red oxide primer and fixing the same to wooden door and window frames as per requirement and direction of Engineer-in-charge.

166.4

-

-

... More
162. PLINTH PROTECTION WORK: Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.

10.5

-

-

... More
163. FLOORING: 2.5 cm A.S. Flooring with cement concrete (1:2:4) including punning using 12mm size crusher broken granite chips with all complete as per direction of engineer in charge.

13

-

-

... More
164. DETAIL ESTIMATE FOR ELECTRICAL: Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I box having modular base & cover plate of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.

-

-

-

... More
a. Light points.

2

-

-

... More
b. Fan point with regulator (electronic step regulator)

1

-

-

... More
165. Supplying and fixing of following modular type switch / socket on the existing switch box / cover including connections etc as required.

-

-

-

... More
a. 5/6 amp. Switch

2

-

-

... More
b. 3 pin 5 / 6 amp socket outlet

2

-

-

... More
166. Supplying and fixing of modular G.I box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface or inrecess with suitable size of modular base & cover plate in front including providing and fixing 3 pin 5 / 6 amps socket outlet and 5 / 6 amps modular type switch, connection, painting etc as required.(For light plugs to be used in non residential buildings)

2

-

-

... More
167. Supplying and fixing of modular G.I box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of modular base & cover plate in front including providing and fixing 5 pin 15 / 16 amps socket outlet and S.P. 15 / 16 amps modular type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings)

1

-

-

... More
168. Supply of all required materials and recessed wiring to circuit / sub-main with followings number and sizes of FRLS 1100 volt grade stranded PVC insulated single core multi-strand copper conductor/ wire of ISI marked run inside 20/25/32 mm dia non-metalic rigid PVC conduit (1.6 mm thick) laid on surface of wall / ceiling or recessed and copper wire as earth continuity conductor and complete in all respect including making good to all damages caused and connection, complete in all respect as per technical specification & direction of Engineer in Charge.

-

-

-

... More
a. 2 x 2.5 sq.mm + 1 x 1.5 sq.mm

10

-

-

... More
b. 2 x 4 sq.mm + 1 x 1.5 sq.mm

10

-

-

... More
c. 2 x 6 sq.mm + 2 x 2.5 sq.mm

12

-

-

... More
169. Supply, installation, testing and commissioning of Company made Branch Distribution Board 2+10 way, SPN, double door, MCB DB, horizontal type doublepole and neutral, sheet steel, MCB distribution board,- Incomming:- 63 amps. DP MCB(10 kA, “C” curve,)- 1 no. Out going- 10/25 amps MCB (10 kA, “C” curve,)-- 8 nos complete including earthing etc. as required complete in all respect as per technical specification & direction of Engineer in Charge

1

-

-

... More
FITTING & FIXTURES: (Sec - B)

-

-

-

... More
170. Providing and fixing of 1 x 10 W LED Philips/Havells make Cat. No. LHLDERUEMD8X010 with testing and complete with all accessories as per the direction of Engineer in charge.

2

-

-

... More
171. Supply, delivery, installation and testing of following sweeps of energysaving star rating a.c. ceiling fan complete with fan blades, down rod, canopies, capacitor etc including supply of sundry materials, making connection froom the suitable point outlet but excluding cost of fan regulator complete as per Electrical Engineer in charge. 1200 mm sweep ceiling fan Panasonic or similar cat. no.- Cool king.

1

-

-

... More
Parking:

-

-

-

... More
172. Filling in foundation trenches and plinths with filling sand, well watered, compacted, dressed and leveled to proper gradient etc., complete as per the direction of the Engineer-in-charge.

29.4

-

-

... More
173. Providing and laying of P.C.C. of 1:4:8 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge..

29.4

-

-

... More
174. Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

196

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.