East Coast Railway Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

East Coast Railway - ECOR Tender

Works
Ireps
Opening Date18 Sep 2024
Closing Date19 Nov 2024
Tender Amount₹ 1,72,05,35,626.58 
Notes
Download

Costs

Summary

Survey, Design, Supply, Installation, Testing And Commissioning Of Kavach Equipments And Other Associated Works Between Ranital Link Cabin (rljc)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"design and drawing of a comprehensive Kavach system for modifications to existing EI/PI/RRI stations, LC installations, and IBS systems in accordance with the revised approved SIP."

110

10000

1100000

... More
Supply,transportation, Installation, Programming, Verification and Commissioning of RFID tags with enclosures and fixures at Stations and block sections(absolute/Automatic Block section). This should comply to RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

21900

16000

350400000

... More
Supply of kit for configuring, programming and downloading RFID Tag data as per RDSO issued guidelines. Inspection by RDSO.

4

1304905

5219620

... More
Supply, installation and commissioning of Test Bench for Station TCAS equipment as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

4

2549583

10198332

... More
Supply, transportation, installation and commissioning of Network Management System for Centralized monitoring of TCAS station and Loco equipment as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

2

9289248

18578496

... More
Supply, Installation and commissioning of kit for configuring, programming and downloading execution and application data for Stationary Station TCAS equipment. Inspection by RDSO.

4

355269

1421076

... More
Supply, Installation and commissioning of Lab Models of station equipment, loco equipment, trackside components and simulator at Headquarters etc as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

2

9473850

18947700

... More
Training to Railway staff for each training package of 300 man-days

600

2509

1505658

... More
Application Safety Case for entire work.

1

10516130

10516130

... More
Fixing of RFID INDICATION BOARD near RFID sleeper with contractors own material and painting Red Stripes on RFID sleeper, As per drawing No.KAVACH/RFID/sleeper/2024. The work shall be done as per instructions of Rly engineer at site. Inspection by consignee.

21900

442

9679800

... More
Testing commissioning of TCAS system in the entire system.

1

15729945

15729945

... More
Supply(including spares), Installation & Commissioning of Locomotive (on board) TCAS Equipment 17 consisting of Vital computer & pheripherals such as Driver Machine interface, 2 RFID Readers, 2 full duplex Radio modems, 4 LTE compatible antenna, 2 GPS and GSM antenna, two number of pulse generator/wheel sensor with direction sensing, and associated cable and power supply arrangement excluding Brake interface unit. This should comply to RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

10

5821883

58218830

... More
Supply and installation of Video Survillance cameras including Audio recording in each Loco with a set of four cameras along with system incl.wiring(Comprises 2 cameras with long distance coverage of atleast 300mts and 2 cameras with a coverage of atleast 10 mts) of 15 days memory storage. Inspection by RDSO.

10

43589

435890

... More
Preparation and Supply of Training e-learning Manuals for On-Board and Trackside System. This need to meet requirements of Railways (EMU & DEMU each one set). Inspection by consignee.

3

175269

525807

... More
Supply of station TCAS Equipment with suitable Rack consisting of Vital computer peripherals, 2 full duplex Radio modems, OFC modems, UHF antenna,GPS and GSM antenna and interfaces as per RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO.

6

3130596

18783576

... More
Supply of RFID tags. Inspection by RDSO.

2190

12800

28032000

... More
Supply of station TCAS RIU (Remote Interface unit) with at least 64 Field I/P's as per RDSO/SPN/196/2020 version 4.0 or latest. The RIU should have provision of OFC or Quad Interface and should be connected to central TCAS in a Ring network. Inspection by RDSO.

10

671058

6710580

... More
Re-programming, Re-fixing and verification of existing RFID Tags.

2500

4700

11750000

... More
Re-programming of existing RFID Tags without shifting.

2500

2000

5000000

... More
Supply, transportation, erection, and grouting of Composite Relay Racks / Relay Racks /CT racks as per Drg.No. SK/DRG/OL/SER/192, SH-1/2 (for Composite Relay Racks), Drg.No. SK/ DRG/OL/SER/192, SH-2/2 (for Relay Racks) and Drg.No. S&T/CON/HQ/VSKP/95/92 (for CT Racks) respectively, including fixing of racks, 1 PBT terminals 1-Way/6-Way, ND Fuses, Bus Bars, Eyelets, Hylum strips of required thickness [12 mm] as per length required at site, condensers and resistances etc., wherever required as per directions of Site Engineer. Inspection of Composite Racks / Relay racks/CT racks by Representative of Railway before use. Tenderer shall supply all the materials from RDSO approved sources such as PBT terminals 1-Way/6-Way, ND Fuses, Fuse blocks, Bus Bars, Eyelets, Hylum strips (12 mm thicknessn ISI Mark) condensers and resistances etc., and any other materials required for the work at his own cost. Inspection by consignee.

63

96053

6051339

... More
Supply, installation, testing and commissioning of Maintenance free and permanent earth as per RDSO Specification No. RDSO/SPN/197 Version 1.0. Inspection by RITES.

10

61717

617170

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fiber cable (48 fibres) and testing 3 as per technical nspecification No.GROJC-2/02 sept 2003. Supply of splice enclosure (24 fiber) shall be as per Boards specification of TEC. All materials including fusion splicing machine used for fiber splicing and OTDR for testing and other testing materials if any shall be arrangeed by the contractor. Inspection by consignee.

20

17783

355660

... More
Supply and installation of rack mounted 48F FDMS fiber part no.fms-1u 48FS 48FP Raychem make 4 including 48Nos 0.2db FC/PC adaptors and 24numbers 900 micron 1.5 meter FCPC pigtails. RDSO Spec No.: RDSO/ SPN/TC-037-2000 (Ver.3) or latest. Make 3M model or similar (latest version). This includes transportation, installation and testing. Inspection by consignee.

10

34220

342200

... More
Supply, transportation, and installation of RCC joint chamber with two piece top cover and bottom 5 cover with hole for drainage and cable entry as per drawing No.RCIL/ER/DRG-02/06 (Section-H). This includes trenching for joint pit, back filling and ramming of pit after placing the joint closure and cable loop in the chamber without causing damage to the same and consolidation of soilas well as disposal of excess soil. Inspection by consignee.

20

11156

223120

... More
Supply and fixing of 'MS-C' channel of size 100mmX50mmX1200mm with suitable clamps as per 7 drawing No. S&T/RE/78/2/76 and fitting to GI pipes of 50/65mm of spec.IS-1239/part-1/ Light with couplings and with suitable clamps on Girder bridges without drilling holes in the girders. Gi pipes are to be drilled with 6 holes of 1/4" dia. per metre around the pipe in zig-zag manner before laying the 6metres GI pipe. the MS Channels shall be inspected by the office in charge of the work before fixing. Inspection by consignee.

500

863

431500

... More
Supply & Laying of G.I Pipes 50mm dia. medium quality (make TATA or Jindal as per Rly. practice) 8 to specification IS.1239 (part-I) 1990 and galvanised to specification IS.4736-1986 On bridges , culverts, trench with channel ramps on either end of the culvert/bridges. Clamping arrangement with MS brackets for fixing of GI pipes on bridges/culverts, small holes of 5mm are to be drilled on the pipe before laying of the pipes. Inspection by consignee.

400

680

272000

... More
"Supply, Transportation and Installation of earth electrode (make TATA or Jindal as per Rly. practice) including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rcak, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG /Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on earthing of S&T 9 equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat (make TATA/Jindal or Similar) to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/ S&T /ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK /13/85 Alt. A). Inspection of Earth Electrode by RITES. NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint.

186

12306

2288916

... More
Wiring and testing of complete Relay Rack / CT Rack / Composite Relay Rack as per wiring diagram for maximum number of plug in type relay & shelf type relays of different sizes or as directed by Railway Engineers at site. This includes rack to rack wiring through MS ladder fixed on the top of the relay rack, crimping eyelets in the terminals fitted in the cables termination rack, numbering by ferrules 2.5 sq. mm, bunching of wires by bunching Tape/Thread and buttons, painting and lettering as required. Wiring of the racks shall be done with PVC 10 wire of size 16/0.2 mm and 3/0.75 mm. Tenderer shall supply all wires & wiring materials purchased from RDSO approved sources. "Note: 1) Only relay and relay bases will be supplied by the Railway. Contractor has to supply all other materials for the above work and make arrangement for transportation of materials supplied by Railway at his own cost. 2) Only brass screws shall be used for fixing of relay bases. 3) All types of wires and wiring materials, eyelets of sizes (make: Dowell's or similar), ferrules (2.5 sq.mm), resin core solder, insulating tape, bunching belt & buttons etc. are to be supplied by the contractor. Wires will be procured from RDSO approved sources only. and all other components will be supplied by the contractor as per requirement at site"

63

158351

9976113

... More
Fixing of relay bases and wiring, bunching, fixing of relays, wiring in Old relay racks/location box and 11 also carrying out any alteration in existing relay rack duly wiring and connecting New to old and Old to old relays by standard wires (RDSO Approved Sources) as per Circuit diagram. Fuses of bases, condensers, ND fuses, LED indicator & its wiring for relay rack. All materials required for this work will be supplied by the contractor from RDSO Approved Sources. Relays with accessories will be supplied by the Railway.

1001

783

783783

... More
"Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (full size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/CON /SK/16. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock 12 only from Railway stores at. Tenderer will supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm thickness], wood plank board of good quality [minimum 3/4"" thick, Cement and transport all the materials to site of work at his own cost. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. 1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the Railway stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size.

120

19438

2332560

... More
Straight through / derivation with / without transformer joints: Installation Thermo shrinkable jointing 13 kits for straight through / derivation joints for LC gate where VF transformers are not required and derivation by using 2T transformer ( to be housed in the joint). This includes tapping of nominated quad at a specific location shown by the Railway Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the contractor.

20

1707

34140

... More
"Alteration of wiring in existing Relay rack/ CT rack/composite relay rack. This includes supply of all 14 types of wires, eyelets, nuts & bolts, bunching material, ferrules, ARA terminals, fuses & fuse blockes by the contractor at his own cost. Lettering & painting to be done by the contractor at his own cost. Wire (RDSO Approved Sources) to be inspected by the representative of Railway before use.

300

28281

8484300

... More
"Excavation of trenches of 1meter depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, 15 ramming, consolidation o f soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found.

6

88821

532926

... More
Excavation of trenches of 0.8 Meter depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, 16 ramming, consolidation o f soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found.

2

71060

142120

... More
Horizontal direction drilling/boringwithout damage of surface ofroad/Track formation. The bore shallbe 150mm dia & shall be at theproper depth as per site conditiondecided by engineer incharge. Theground 17 level shall be consideredignoring the bank height of the bankof the Road. The length of the boreshall be minimum 4mtrs long. Thisinclude insertion of different diaDWC pipe GI/HDPE pipes couplingetc. as per as per direction ofEngineer In-charge. Note: The costof pipe is not included in this item.Contractor shall provide allmaterials required for boring andadequate no of labour for properlaying of cables into the bore. Cableshall be laid cautiously so that itshould not get damage due to roughhandling & pressure on cable.

1000

1486

1486000

... More
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and width 0.3 Mts. at the 18 bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.

3000

255

765000

... More
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through 19 the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.

30

25563

766890

... More
Breaking of RCC concrete in Relay Room / Panel Room for drawing cables.

83

6485

538255

... More
Track crossing by horizontal boring method. As per Section-H

500

3902

1951000

... More
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split RCC/G.I. 22 pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.

1500

335

502500

... More
Jungle cutting along with the cable route and near towers

501

7

3507

... More
Breaking of metal/tar road and refiiling after laying of cables as per drawing no. SDO/CABLE LAYING 010. The surface of road shall be concreted to match the old surface

500

248

124000

... More
Excavation of trench at the culvert from foot to top of it in the ramp to a size of 300mm width, 26 800mm depth by storing the ballast and excavates soil separately laying o f the HDPE/DWCpipe uaing couplers and bends as per d rawingNo.SK.15/11, drawing of cables through the pipe and refilling of the trench duly putting back the removed ballast in its proper shape and place.

500

139

69500

... More
Supply, transportation & laying of Injection-molded cable channel of size width (int/ext) 240/340 mm 27 height (int/ext) 155/230 mm , Lenth 1 Meter ( 10mm), weight per meter 8 Kg (Top and Bottom). Material Polyolefin Engineering Plastic with fireprotection class V0 following DIN - 53438 Part II, for laying Signalling / Telecom Cables. As per RDSO Technical Specification STS/Cable - Laying practices Vol - IV, Dt. 09.05.2018 in DIN 53438 Parts - II. as per section-H, Inspection by RITES.

945

3100

2929500

... More
Design of cable route plan, as per technical specification and supply of 6 sets of documents in 28 proper binding from approved drawings shall be taken and submitted to Railways. This includes (but not limited to) circuit diagram, RFID Tag-TIN layouts, Table of Control for entire section, Stationary and Loco TCAS interface diagrams, power supply diagram and other manuals as specified in the tender document.(set means 1 station and adjacent Block section)

52

145990

7591480

... More
Transportation of materials from any Stores to Site and vice-versa including loading and unloading. (i)Lead above 50 Kms. (Kilometre = Per Ton Per Kilometre)

328904

8

2631232

... More
Transportation of HDPE pipe from the store to work site, laying of the same (With 4 mm nylon rope, 30 pre inserted inside the HDPE pipe) in excavated trench/ already laid GI/ RCC pipe / tubes, jointing, leveling and end sealing the pipes, HDPE pipe, couplers and end caps shall be supplied by Railway, Nylon rope shall be supplied by the contractor.

30

15746

472380

... More
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through 31 the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.

30

25563

766890

... More
Supply, installation and commissioning of SMPS based 110V/24-32V DC-DC converters containing 4 no. of 24-32V, 5 Amps DC/DC converter (internal (1+1), external (1+1)) .Inspection by RDSO.

62

67149

4163274.58

... More
Alteration of database, faults, simulations in Data loggers and all connected places (like HQ, FEP, STATION, etc)

53

18370

973610

... More
Transportation, installation, wiring of Integrated Power Supply system. Railway will supply only IPS system, red and black copper cable of 25 Sq mm size or as required as IS: 694 and grade 1100 V for connecting IPS to battery bank for 300/200 AH battery. Tenderer shall supply all wires and wiring materials required for the 34 installation including DPDT switches of required numbers of ANCHOR/CROMPTON/HAVELLS/L&T to make 250V AC 32 Amps/415 V AC 63/100 Amps capacity or as per requirement. Electric wiring and bringing AC input supply from auto change over CLS panel at the station to IPS, all wiring /ducting from SM room to IPS room, from IPS room to relay room or any other load to be done by the contractor. All other copper cable of required dia as per installation manual and other wiring materials to be used for power wiring will be supplied by the contractor at his own cost.

2

94435

188870

... More
Transportation, Charging, installation, wiring of low maintenance Secondary cells as per manufacture's instructions and Railway's directive. This includes supply of distilled water and sulphuric acid by the 35 contractor at his own cost. The un charged batteries with connector shall be supplied by the Railway. Materials including 3/0.29 PVC wires, battery connector , brass bolts and nuts , PVC tapes eyelets, etc and all other materials shall be supplied by the contractor. Note: [1] Before completion of works contractor shall prepare jointly with Railway Engineer at site and submitt battery capacity test report as per approved format of Railway and hand over all relevant records to the Railway. [2] All the cells failing in the discharged capacity test in the Railway premises will be replaced by new ones free of cost. Railway Engineers decision shall be final. . Capacity test register ( binded size no. 10) in prescribed format shall be supplied by the contractor. In case of failure in capacity test tenderer will be responsible for fresh charging/replacement of the batteries. (i) 2 Volts/200 AH.

600

570

342504

... More
Hiring of Skilled Labour assistance SE/JE in day to day works i.e. assisting for exact fixing of RFID 1 tags, TCAS units, identifying ECR/ECPR contacts, static and dynamic testing, taking of measurements, nothing of daily work status, carrying the tools & equipments etc watch & ward during the course of execution of workas per the instructions of cenerned SE/JE (as per chief labour commissioner letter No.1/131/1/2016-LS-II dt:31.3.16)

1775

1039

1844225

... More
Hiring of Unskilled Labour assistance SE/JE in day to day works i.e. giving marking of cable route, 2 cable laying, taking of measurements, noting of daily work status, carrying the tools & equipment etc., watch & ward during the course of execution of work as per the instructions of cenerned SE/JE (as per chief labour commissioner letter No.1/131/1/2016-LS-II dt:31.3.16)

1775

785

1393375

... More
Supply of Permanently lubricated two layer type HDPE duct, outer dia 40 mm, inner dia 33 mm with 1 three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. ROSO/SPN/TC/45/2013 .Rev.2.0 Amendment 2.0 or latest.Inspection by RITES. Note:- The HDPE duct should be pre inserted with 4 mm nylon rope, inside the HDPE duct.

30

138511

4155330

... More
Supply of Relay, Non-AC immune plug in type, style QN1, DC neutal line, 24 V, 12F.4B contacts, 2 front and back contacts metal to carbon with plug board, retaining clip & connectorsconforming to BRS: 930, IRS S34 & IRS: S 23 (as applicable) The interlocking code for this unit shall be ABCDF (with ATC clips). Inspection by RDSO.

7540

6471

48791340

... More
Supply of Relay AC immune, plug-in-type Style 'QNA1, DC neutral line, 24V, 12F.4B contacts, front and back contacts metal to carbon with plug board retaining clip and connectors confirming to BRS 931A, IRS-S60, IRS-S34 and IRS-S23 (as applicable). The interlocking code for this unit shall be ABDFH.(Inspection by RDSO)

100

6720

672000

... More
Supply of indoor Signaling cable 60 core x 0.6mm as per IRS S76/89 amend no 3 or latest. Inspection by RDSO.

13

158264

2057432

... More
Supply of WAGO/ELMEX/PHOENIX terminal as per RDSO spec 189/2004. Inspection by consignee.

4000

816

3264000

... More
Supply of Steel Apparatus case 'large Size' as per Drg. No - CON/SK/1/1/86 and Spec.No. IRS:S- 10/78 (adv) with latest amnd. with "E" type lock and key of ward No-32 with handle. Inspection by RITES.

120

42507

5100840

... More
Supply and fixing of 20 mm thick teak wood planks for keeping equipments in full box after applying two coats of wood primer. The approximate size of pank is 940 mm x 20mm x 300 mm. Inspection by consignee.

120

854

102480

... More
Supply of PVC insulated wire multi-strand per conductor 10 Sq.mm flexible. Spec IRS S76/89. Amendment No 2 or latest. Each coil of 100 mts length To be procured from RDSO approved firms (SIZE 140/03 mm). Inspection by RDSO.

15766

7637

120404942

... More
Supply of lightening and surge arrestors of class B&C suitable for single phase supply in TT network as per amendment 5 of RDSO spec.No.RDSO/SPN/165/2004 or or Latest and as recommended by RDSO letter No.STS /E/IPS/GENL dtd: 27.01.06 (Amendment 5). Inspection by RITES.

12

25184

302208

... More
Supply of E type locks of different ward as per requirement with key per E-type lock to Drg No.S A.3376/M/Latest and RDSO spec no lRS. S.30/64. Inspection by consignee.

120

940

112800

... More
Supply of Universal lock with one key for every 10 locks. Inspection by consignee.

120

101

12120

... More
Supply of 19" 42 U covered racks complete with all fittings and accessories for housing SDH equipments, primary Muxs, krone modules for 60 channels (2 x 30), DDFs,for 30 channels and other equipments 12 like runway ladders, fan tray etc completely wired and equipped with integrated protection modules for all 30 circuits. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. This includes with the DC-DC Panel with MCB (Min. 05 -48V DC) , 230V AC distribution panel and installation, testing and commissioning of the system. Inspection by consignee.

105

76848

8069040

... More
Supply of Thermo shrinkable jointing kit as per Spec. No. IRS TC. 77/2012(Rev 3) Amd 3 for all types joints suitable for 6 Quad Jelly filled UG cable. Inspection by RDSO.

32

6143

196576

... More
Supply of DWC pipe of 63 mm outer dia/50 mm inner dia in lengts of 6 Mtr with coupler. to IS specification No.14930 Part-II.The IS spec shall be marked on the pipe. Inspection by RITES.

2568

708

1818144

... More
Supply of Digital Earth Tester 0.01 to 99 Ohms.In 5 ranges 4 terminals type with all facilities WACO make or similar. Inspection by consignee.

4

24327

97308

... More
Supply of AC/DC Digital clamp meter Fluke-376 or similar. Inspection by consignee.

4

83661

334644

... More
Supply of Insulation resistance tester 500V DC 500 Mega Ohms hand generator type metal body to Spec. no. IS:2992 make WACO. Inspection by consignee.

2

17857

35714

... More
Supply of Insulation resistance tester 100 V DC 500 Mega Ohms hand generator type metal body to Spec. no. IS:2992 make WACO. Inspection by consignee.

1

13789

13789

... More
Supply of Digital multimeter Fluke-287 or latest higher version with testing lead complete with case and spare set of batteries. Inspection by consignee.

4

114234

456936

... More
Supply of portable Cable fault locator (Metallic Time Domain Reflectometer) suitable in RE/Non RE Railway territory with all accessories for locating faults such as loop and break in various twisted pair cable such as 20 underground telecom quad cables, signalling cables , telephone jelly filled cables, LAN etc. Instrument to be supplied with protective nylon carrying bag and operators manual. make/model:Radio detection riser bond,Model 3300 or make/model;RC-RT (TDR) MRPC/Rail 2018 or latest equivalent along with other OEM or OEM authorised with documentary proof. Inspection by RITES.

4

382612

1530448

... More
Supply of High Power, Electronic Cable Route Tracer/ Pipe and Cable locating kit with 36 user configurable Active multi frequency options including 200Hz, 512Hz, 797Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 200kHz upto 476.2kHz, passive detection @ 50Hz for power cables, Radio Mode for locating metallic utilities 21 whether energised or not, Current measurement, LCD Display with left-right arrow function , Modes: peak, peak with arrow, pin point peak and null modes, Compass function; Depth measurement. Supply includes locating receiver, Transmitter (Max power : 12Watt) with Li-ion Rechargeable Batteries for both Transmitter & Receiver,Battery charger, Induction Signal Clamp 4'', supplied in a carry bag. Similar to 3M-Dynate/Radio detection / Stanlay Pathfinder LOC10. Inspection by RITES.

4

379188

1516752

... More
Supply and installation of 64 input digital stack card for Data Logger. Inspection by RDSO.

106

21225

2249850

... More
Supply and installation of Digital Data Logger mother board to upgrade from 512 to 1024/2560 or higher digital inputs. Inspection by RDSO.

53

58958

3124774

... More
Supply of Datalogger complete to spec No- IRS:S:99/2006 AMD. 3 or latest with configuration of 512 digital inputs and 64Analog inputs with self power supply system, protocol converters as required etc with networking facilities. Inspection of Data Logger by RDSO & balance item by representative of Railway. This includes supplying of two Nos. of door sensors for each Data logger. Inspection by the consignee

1

579524

579524

... More
Supply of Program Maintenance Console for system monitoring. Inspection by consignee.

1

39000

39000

... More
Supply, Installation, testing and commissioning of Lead Acid Secondary cells of capacity 2V, 200AH. Inspection by RDSO.

600

5171

3102918

... More
Supply, Installation, testing and commissioning of Mini SMPS based Integrated power supply 2 system(IPS) confirming to RDSO specification No. RDSO/SPN/165/2012[Ver.3.0] or latest with latest Amendmend as on date of opening of the Tender and as per East Coast Railway Drawing No. CSTE/ECOR/TYP/2/11/AIt2 Including supply of additional spares as per approved drawing Inspection by RDSO.

1

1275438

1275438

... More
Supply of SMPS BASED INTEGRATED POWER SUPPLY SYSTEM (IPS) CONFIRMING TO RDSO SPECIFICATION NO. RDSO/SPN/165/2023 (VER 4.0) WITH LATEST AMENDMENT AS ON THE DATE OF 3 OPENING OF THE TENDER AS PER E.CO.RLY DRAWING No.CSTE/ECOR/TYP/4/11/ALT2 INCLUDING SUPPLY OF ADDITIONAL SPARES AS PER APPROVED DRAWING. THE MANDATORY TOOLS AND SPARES TO BE SUPPLIED AS PER RDSO SPECIFICATION.Specifications as mentioned. Inspection by RDSO. Note: This isinclusive of supply of Battery set asper load requirement and initialcharging & discharging.

1

2079862

2079862



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.