East Coast Railway Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

East Coast Railway - ECOR Tender

Works
Electrical and Electronics
Electrical Works
Ireps
+3Cuttack, OdishaAngul, OdishaDhenkanal, Odisha
Opening Date25 Oct 2024
Closing Date10 Dec 2024
Tender Amount₹ 3,32,80,53,936.77 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
11(a)(ii) Supply without Insulator and erection of a suspension (9 Tonne) Insulator 105

-

-

14199944.79

... More
11(b) Supply without Insulator and erection of 25 kV Post Insulator 106

-

-

1841169.83

... More
17 (b) Extra for special embedment of earth electrode. 107

-

-

132924.44

... More
25(a) Supply and Installation of cables for Control and indication circuit 110

-

-

7926655.36

... More
25 (b) Supply and Installation of cables for Heater supply 111

-

-

1397762.1

... More
25 (c) Supply and Installation of cables for Catenary indication 112

-

-

2743842.24

... More
25 (d) Supply and Installation of cables for L.T. Power supply 113

-

-

592515.4

... More
27(a) Supply, Erection, oil- filtration, testing and commissioning of L.T. supply transformers (10 kVA).

-

-

1252817.69

... More
27(c) Supply, Erection, oil- filtration, testing and commissioning of L.T. supply transformers (25kVA).

-

-

256277.27

... More
27 (d) Supply, Erection, oil- filtration, testing and commissioning of L.T. supply transformers (50 kVA). 117

-

-

988339.18

... More
28. Supply without Insulator & erection of 25 kV D.O. fuse switch. 118

-

-

256548.73

... More
31(i) Dismantling of an Isolator 119

-

-

173479.11

... More
31(j) Dismantling of a post/pin insulator 120

-

-

133120.2

... More
31(m)(i)Manning of Switching stations (SP/SSP) 121

-

-

5397851.84

... More
"2 (a) Concrete for foundation and plinth (For M-10 and M-15 grade concrete)" 202

-

-

41732999.28

... More
"2(az) Concrete for foundation and plinth (For M-15 and M-20 grade concrete)" 203

-

-

19320744.24

... More
"2 (b) In other than hard soil and rock (For M-10 and M-15 grade concrete)" 204

-

-

432332208

... More
"2(bz) In other than hard soil and rock (For M-15 and M-20 grade concrete)" 205

-

-

127283171.4

... More
2 (cz) Reinforced concrete for foundation and plinth in other than hard soil & rock (Grade M-20) 207

-

-

751309.02

... More
34(e)(ii) Construction of retaining / Baffle wall with RCC M-20 208

-

-

730459.3

... More
3(a)(ii) Supply & Erection of traction masts, main masts of switching stations, Booster transformer station, fabricated from Rolled mild steel joist (RSJ) of size 203mm x 152 mm x 52.0 Kg/m and galvanised in various lengths

-

-

22052882.45

... More
3(b)(i) Supply and erection of fabricated and galvanised structures (O, N & R type portals) with all necessary components other than masts

-

-

41744512.02

... More
3(b)(ii)Supply and erection of Structure steel (traction masts) fabricated and galvanised of all Type : B - series mast.

-

-

481097863.5

... More
3(b)(iii) Supply & Erection of special fabricated and galvanised steel structures other than Portals & traction- Masts not covered under items 3(b)(i) & 3(b)(ii). 305

-

-

93918462.97

... More
3(c) Supply only of fabricated steel other than masts 306

-

-

95548557.13

... More
3(e)(i) Supply and erection of a Guy Rod Assembly 307

-

-

24002589.68

... More
3(i) Supply and erection of 25KV Caution Boards/Plates. 308

-

-

76763.56

... More
16(a)(i) Supply and erection of a structure bond 309

-

-

21930861

... More
16 (c) Supply and erection of a transverse and special bond 310

-

-

2725550.1

... More
17(a) Supply & erection of a single earth electrode. Incl SP and SSP 311

-

-

13677336.21

... More
17(c) Supply and erection of earth bus 312

-

-

4607810.34

... More
17(e) Supply and erection of 8 SWG G.I. wire for earthing 313

-

-

53246.4

... More
30 (a)(i) Supply and erection of fencing panels at switching stations. 314

-

-

11925196.86

... More
30(a)(ii) Supply and erection of fencing uprights TSS SP and SSP 315

-

-

4354224.36

... More
30(b) (iii) Supply and erection of anti climbing device for L.T. Supply Transformer Stations. 317

-

-

13897.31

... More
30(b)(iv) Supply and erection of anti monkey menace 318

-

-

148757.13

... More
3(g) Supply of steel reinforcement for RCC 319

-

-

2339014.52

... More
7(d) Supply and Manual Erection of all aluminium 25KV Feeder/ Return conductor (Single Spider)

-

-

145348944.32

... More
7(e) Supply and Erection of copper cross feeder wires (37/2.25 mm HDBC) across the track at SP/SSP/FP/BT locations

-

-

31081968.74

... More
12(d)Supply & erection of a ceramic/beaded glass fibre type (PTFE) short Neutral section Assembly

-

-

24799010.72

... More
13(a)Supply without Insulator and erection of 25 KV SP Isolators without earth contact assembly. 405

-

-

1198703.29

... More
13 (d) Extra for supply and erection of an earth contact assembly in an isolator 406

-

-

73225.79

... More
15a(ii) Supply & erection of small copper jumper 407

-

-

23167424.35

... More
15(az)(iii) Supply and erection of small copper jumper 408

-

-

94933.04

... More
15(a)(iv) Supply and erection of a copper jumper (5mm dia dropper wire) 409

-

-

140338.82

... More
15(d) Supply of materials and erection of Large copper jumper 160 Sq. mm between Aluminium bus and cross feeders

-

-

8555782.34

... More
15(e) Supply of materials and erection of Large copper jumper 160 Sq. mm between cross feeder and OHE 412

-

-

14834317.87

... More
17(d) Supply and erection of copper strips for equipment earthing.TSS,SP and SSP 413

-

-

1753945.8

... More
26(a)(i) Supply & erection of : Aluminum bus-bars 36mm x 28mm 414

-

-

65411.18

... More
26(a)(ii)Supply & erection of Solid copper bus-bars 18mm.: 415

-

-

1399394.05

... More
26(b)(i) Supply and erection of Aluminum bus-bar connectors:- Bus terminal (6480-1) 416

-

-

157449.92

... More
26(b)(iii) Supply and erection of Aluminum bus-bar connectors:- Bus tee connector (6500-1)

-

-

87523.63

... More
26(b)(iv) Supply and erection of Aluminum bus-bar connectors:- Terminal connector 36/20 (6530-1) 419

-

-

79072.28

... More
26(b) (vii) Supply and erection of Aluminum bus-bar connectors:- Terminal connector Bolted Type (6830-1) 421

-

-

62748.42

... More
26(c)(i)Supply & erection of solid copper bus-bar connectors: Bus terminal (6310-1) 422

-

-

670030.45

... More
5(ax)(i) , 8(bx)(i) 9(ax)(i) & 11(ax)(i) Supply of 9 -Tonne insulators for item 5(az))(ii), 9(a) & 9dz), 11(a)(i) & 11(a)(ii) 8(b)(ii) &8(b)(iii) Porcelain (CD-1050) 502

-

-

42049886.52

... More
11(bx) Supply of 25 kV Post Insulator for Item 105 & isolators incl SP, SSP and TSS 503

-

-

24708672.43

... More
4(ax) (i)Supply of Stay arm Insulator Porcelain (CD1050) 505

-

-

201911.49

... More
Preparation of Design and Drawing for OHE and feeder for 2x25 KV system. 602

-

-

6714739.72

... More
Supply & erection of retro reflective number plate 603

-

-

12579900

... More
Supply & erection of Tee connector for BEC end and lug for connector (Rate incl of erection) 605

-

-

46691918

... More
Digging of trench 300 mm deep 606

-

-

19051251.04

... More
Laying and back filling of trench 300 mm deep and repair in platform area 607

-

-

18289197.44

... More
Supply & Erection of MS Flat for earth 50mm X 6 mm 608

-

-

7796568

... More
Drilling of Rail hole 609

-

-

698318

... More
Supply & erection of 55/66 kV DP Isolator complete with SPS 610

-

-

10864591.9

... More
Supply & erection of 12.24mm dia ACSR Racoon with suitable(AEC) fastners 611

-

-

29521720.72

... More
Dismantling of PTFE neutral section 612

-

-

386283.52

... More
Dismantling of Copper Cross Feeder (150 sq.mm.)/Aluminium Feeder Conductor (Single Spider)/ 130Sqmm Large Span wire 614

-

-

82450

... More
Supply and erection of Caution Board for 25KV 615

-

-

58416

... More
Retro Reflective Warning Board for Neutral Section 250 mtrs/500 mtr/DJ OPEN/DJ CLOSE/MEMU including Fixing Arrangement.

-

-

286279.68

... More
Supply and drilling and grouting of Galvanized Holding Down Bolt of Size 28mm dia, 950mm length with 100mm threaded portion and 850mm ragged type confirming to IS 2062-92 (Gr- A) including Washers & Nuts. On bridge pier. 618

-

-

955732.5

... More
Dismantling of Portal/TTC Boom Assembly 619

-

-

1561200

... More
Dismantling of Structure Bond /Rail/Special Bond with Bolt & Nuts 620

-

-

32020

... More
Dismantling of C/G/ATJ/ Aluminium Jumper with PG Clamps 621

-

-

1945040

... More
Cutting of Hard Concrete in any Shape & Size 622

-

-

1810284

... More
Dismantling of Solid core Suspension Insulator with SPS

-

-

542250

... More
Route Mapping of OHE Assets i.e. OHE/Pole Mast in OLIVER-G with GPS Systems for Current collection Test of all the Electrified lines and loading of GPS Mapping data. 625

-

-

282401.71

... More
Retrieval of Mast/TTU from Solid Core Foundations without damage or leaning of Mast. 626

-

-

536426

... More
Supply and erection of Sectioning Diagram Boards at stn, TPC & Sec CNL 627

-

-

850640

... More
Supply of 240Sqmm XLPE Copper cable of 26KV/45KV(52KV) suitable for 25 KV traction system as per IEC 60840

-

-

12234375

... More
Laying of one number XLPE powe cable of grade26KV/45KV(52KV) , 240 sqmm direct in ground including excavation, sand cushioning, protetective covering (By Bricks) and refilling the trench.etc. as required

-

-

424500

... More
Supply, Erection, Testing and Commissioning of 26KV/45KV(52KV) out Door cable Termination Kit (Heat Shrinkable)

-

-

551520

... More
Laying of HT cable (XLPE) of size 1core x 240 sq.mm. in trench through GI pipe/RCC pipe / along or across the structures. With suitable arrangement along with clamps, fastner etc (Price of insulators covered in Schedule -1, Section 5)

-

-

82300

... More
"Cable route indicator (G.I type) Supplying and making cable route marker with 10cm X 10cm 5mm thick G.I plate with inscription there on bolted, welded to 35 mm X 6mm angle iron 60cm long and fixing the same in ground as required"

-

-

7875

... More
Supply Erection,testing and commissioning of 16.5MVA, 54KV/27KV 50HZ Auto Transformer with bushing,oil and other equipments as per RDSO specification TI/SPC/PSI/AUTOTR/1200 (02/21) 702

-

-

371218560

... More
Supply, erection, testing and commissioning of 27.5/110V PT type-I or Type -II as the case (52KV insulation class) . TI/SPC/PSI/ PT/0210(06/21)

-

-

13295744

... More
Supply and erection of 25KV strung Bus termination arrangement style 1 & 2 with insulators with required connectors adjusters etc for SP/SSP 705

-

-

1108128

... More
"Supply and erection of 150AH, 110 V low maintenance lead acid (LMLA) batteries set with 02 Nos battery charger RDSO Spec RDSO/PE/SPEC/TL/0040 (Rev-2) 2021 & TI/SPC/PSI/200-250/ CHGR/0210 (07/21)" 707

-

-

2682276

... More
Supply and erection of 240V AC distribution panel for SP/SSP 708

-

-

404496

... More
Supply and fixing of heavy duty ISI marked 'B' class GI pipe of 3065 mm wall thicknes and 50mm dia to be laid along the wall or floor with proper galvanised clamps/through the wall or underneath the floor in cement concrete or otherwise.for TSS/SP/SSP

-

-

215040

... More
Supply, erection, testing and commissioning of Control relay panel for SP in 2x25 KV system as per RDSO specification TI/SPC/PSI/PROTCT/7100(07/2012) with A&C No1 or latest (Procurement may be done in accordance with the approved drawing) Four Line section

-

-

32644700

... More
Supply, erection, testing and commissioning of Control relay panel for SSP in 2x25 KV system as per RDSO specification TI/SPC/PSI/PROTCT/7100(07/2012) with A&C No1 or latest (Procurement may be done in accordance with the approved drawing) Four Line section

-

-

45702580

... More
Supply erection testing and commissioning of 25 KV double pole vacuum type interrupter (2000A) as per RDSO Spec TI/SPC/PSI/LVCBIN/0121 or latest with steel support structure and terminal connector.

-

-

101097606

... More
Supply erection testing and commissioning of motorized 25KV 2000A double pole Isolator (without insulator and earthing mechanism ) RDSO Specc TI/SPC/PSI/ISOLTR/0210(06/21)

-

-

9075144

... More
Supply and erection of manually operated 25KV, 2000A Double pole isolator without earth blade and insulator with interlocking TI/SPC/PSI/ISOLTR/0210 (06/21)

-

-

28329855

... More
Supply,erection, testing and commissioning of Automatic Fault Locator (AFL) for 2x25 KV AC traction system based on auto transformer neutral current ratio as per RDSO Specification TI/SPC/AFL.0240 or latest for SP

-

-

14250000

... More
Supply,erection, testing and commissioning of Automatic Fault Locator (AFL) for 2x25 KV AC traction system based on auto transformer neutral current ratio as per RDSO Specification TI/SPC/AFL.0240 or latest for SSP 719

-

-

15050000

... More
2(a)(i) Concrete for foundation & trench in hard soil 902

-

-

1996812.9

... More
2(a)(ii) Concrete for foundation & trench in rock. 903

-

-

2209207.98

... More
"2(b)Concrete for foundation & trench In other than hard soil and rock " 904

-

-

45015791.04

... More
2(C) (i)Reinforced Concrete for Foundation, Baffle wall & Trench 905

-

-

4520126.28

... More
2(C)(ii) Reinforced Concrete for Cable Trench Covers. 906

-

-

1648305.48

... More
2 (d) (i) Reinforced Brick Work for Baffle Wall. 907

-

-

6026336.46

... More
"3.Supply, fabrication, galvanisation & erection of steel gantries/portals supporting structures and small parts steel work." 909

-

-

50348104.14

... More
26 (a) Supply and Erection Fencing Panel at Traction Sub Station (TSS). 910

-

-

3424646.3

... More
26 (C) Supply & erection of gates TSS, SP and SSP 911

-

-

301989.91

... More
26 (d) Supply & Erection of Anti climbing Device at Substation. 912

-

-

549235.73

... More
7. Supply & Erection of 120 kV Lighting Arrestors. 913

-

-

10922790.92

... More
17 (a) Supply, Erection of ACSR Zebra Conductor of Size- 28.62 mm dia. 914

-

-

2788059.36

... More
17 (c)(i) Rigid bimetallic terminal connector suitable for 50 dia Aluminium tubular busbar to terminal pad of 25kV Isolator/CT (ID-11090).

-

-

2176301.7

... More
17 (C) (ii)Details of expansion type terminal connector to suit 50 dia Aluminium tubular busbar, terminal pad of 25kV CT/Isolator (ID-11060).

-

-

1868428.55

... More
17 (c) (iii) 25kV system rigid Bus splice connector to suit 50 O/D Aluminium tube on both ways (ID- 11180)

-

-

897444

... More
17 (c) (iv) 25kV system TEE connector to suit 50 O/D Aluminium tubular Busbar (ID- 11150).

-

-

952287.8

... More
17 (C) (v) Rigid through connector to suit 50 dia Aluminium tubular Busbar & SPIDER AAC conductor for 25kV P.T. Type-II (ID-11110). 920

-

-

254275.8

... More
17 (C)(vii) 25kV system Tee connector to suit 50, O/D Aluminium tubular Spider AAC conductor (ID-11140).

-

-

426784.48

... More
17 (C)(viii) system Tee to suit ZEBRA /Berisimis ACSR conductor on both ways (ID- 11040).

-

-

1824802.8

... More
17 (C)(ix) Rigid terminal conductor suitable for 20 dia Al. conductor to terminal pad of 132/66 kV CB, Isolator & 25kV PT Type I & II (ID-11120). 924

-

-

1322832.46

... More
17 (C) (x) Rigid connector on SI to suit 50 mm O/D Al. Bus bar (ID-11200). 925

-

-

453707.8

... More
17 (C)(xi) Sliding clamp for 50mm O/D Al. busbar (ID-11190). " 926

-

-

134367.31

... More
17 (C)(xiii) 25kV system TEE connector to suit 36 O/D Al. Busbar to 50mm O/D Al.Busbar (ID-11240) 928

-

-

285686.34

... More
18 (a) Supply & erection of 132 kV Support Insulator. 929

-

-

2294584.82

... More
18 (a)(II) Supply & erection of 50/66 kV Support Insulator. 930

-

-

1898991.5

... More
18 (b) Supply & erection of 25kV Support Insulator 931

-

-

2376730.86

... More
18 (c) (ii) Supply and erection of 132 KV termination with disc insulator without adjuster.

-

-

2363643.14

... More
18(c) (i)(a)Supply and erection of 55/66 KV termination with disc insulator with adjuster for Berisimis conductor

-

-

1231293.17

... More
18(c) (ii)(a)Supply and erection of 55/66 KV termination with disc insulator without adjuster for Berisimis conductor

-

-

1127907.62

... More
"23(a) For circuit breakers & Interrupter control and indication circuits. (7x2.5sq mm copper) " 936

-

-

4004843.85

... More
23(b) For transformer alarm/trip circuits & tap changer control.(10x2.5 sqmm copper) 937

-

-

780776.28

... More
23 (d) Current transformer circuits 110V DC & 240V AC supply circuits. (2x4sqmm copper)" 939

-

-

830135.7

... More
23(e) Potential transformer and 240V AC Supply Circuits.(2x2.5 sqmm copper) 940

-

-

1292319.36

... More
23 (f) 240V Heater Circuit(2x4 sqmm Aluminium) 941

-

-

471158.1

... More
23 (g) L.T. Power supply to control room.(2C 300 sqmm Al.) 942

-

-

1645314

... More
24 (a) Earth electrode. 943

-

-

1456102.89

... More
24 (b) Earth leads 75mm x 8mm mild steel laid in the ground. 944

-

-

1597450.32

... More
24 (c) Earth leads 50mm x 6mm mild steel laid in the ground 945

-

-

717955.2

... More
24 (d) Earth leads 75mm x 8mm mild steel flat laid exposed 946

-

-

490602.72

... More
24 (e) Earth leads 50mm x 6mm mild steel flat laid exposed. 947

-

-

344020.2

... More
24 (f) 8 SWG G.I Wire for earthing. 948

-

-

32906.28

... More
24 (g) 32mm dia MS Rod for earth mat. 949

-

-

5085516

... More
25 (a) Supply & erection of earth screen wires. TSS,SP,SSP 950

-

-

1947453.48

... More
Erection, testing and commissioning of 132 KV/2x25KV 60/84/100MVA ONAN/ONAF three phase scott connected power transformer (Transformer will be supplied by Rly)

-

-

34502610

... More
Supply, installation, testing and commissioning of 132KV triple pole isolator with insulators (Manually operated) (TI/SPC/PSI/ISOLTR/0210(06/21)

-

-

1843935

... More
Extra for supply and erection of earthing blade assembly for 132KV Triple pole isolator 1250A

-

-

784128

... More
Supply, installation, testing and commissioning of 132KV CT (800-400/5A, TI/SPC/PSI/CT/0210(06/21)

-

-

1870200

... More
Supply, installation and commissioning of 25KV double pole vacuum circuit breaker with interlocking 2000A TI/SPC/PSI/LVCBIN/0120(12/13) with A&C slip no. 01

-

-

86603225

... More
Supply and erection of 50/66 KV 2000A double pole isolator manually operated TI/SPC/PSI/ISOLTR/0210(06/21)

-

-

1512852

... More
Supply, installation, testing and commissioning of 50 KV CT (1500-750/5A, TI/SPC/PSI/CT/0210(06/21) 010

-

-

2380200

... More
Supply Erection, testing and commissioning of 12.3MVA, 54KV/27KV 50HZ Auto Transformer with bushing, oil and other equipment as per RDSO specification TI/SPC/PSI/AUTOTR/1200 (02/21)

-

-

139447680

... More
Supply,erection, testing and commissioning of Automatic Fault Locator (AFL) for 2x25 KV AC traction system based on auto transformer neutral current ratio as per RDSO Specification TI/SPC/AFL.0240 or latest for TSS 013

-

-

14700000

... More
"Supply and erection of 250AH, 110 V low maintenance lead acid (LMLA) batteries set with 02 Nos battery charger RDSO Spec RDSO/PE/SPEC/TL/0040 (Rev-2) 2021 & TI/SPC/PSI/200-250/ CHGR/0210 (07/21)"

-

-

1515996

... More
Supply, erection, testing and commissioning of Shunt capacitor bank 2400kVAR at 25kV TI/SPC/PSI/FC&SR/0100 (01/10)

-

-

3074352

... More
Supply, erection, testing and commissioning of low loss Series Reactor TI/SPC/PSI/FC&SR/0100 (01/10)

-

-

3646488

... More
Supply, erection, testing and commissioning of Control relay panel for scott connected 2x25 KV TSS as per RDSO specification TI/SPC/PSI/PROTCT/7100(07/2012) with A&C No1 or latest. 04Line

-

-

69308775

... More
Supply, erection, testing and commissioning of Control relay panel for capacitor bank for 2x25 KV scott connected TSS as per RDSO specification TI/SPC/PSI/PROTCT/7100(07/2012) with A&C No1 or latest

-

-

10327596

... More
Supply, installation and commissioning of 50 KV double pole vacuum circuit breaker 2000A TI/SPC/PSI/HVCB/0121(05/21)

-

-

20176530

... More
Supply erection testing and commissioning of 25KV CT , 1500-750--/5A as per RDSO spec TI/SPC/PSI/CT/0210(07/21) or latest

-

-

2673594

... More
Supply erection testing and commissioning of 25KV CT , 200-100/5A as per RDSO spec TI/SPC/PSI/CT/0210(07/21) or latest

-

-

1297584

... More
Supply erection testing and commissioning of 25KV NCT , 2/1 as per RDSO spec TI/SPC/PSI/CT/0210(07/21) or latest

-

-

929700

... More
Supply, erection, testing and commissioning of 60KV LA

-

-

30

... More
Supply and erection of 240V AC distribution panel for TSS TI/SPC/PSI/LTDPNL/0210 (10/21) 032

-

-

381462

... More
Supply and erection of 110V DC distribution board for TSS/SP/SSP 033

-

-

526095

... More
Supply and fixing of First aid box & shock treatment chart 034

-

-

6720

... More
Supply and fixing of various types of indication boards and caution boards 035

-

-

318300

... More
Supply and fixing of the board showing First aid and nearest doctor name and adress /nearest fire fighting name and address (350mmx500mm)

-

-

3090

... More
Supply and fixing of wooden key box with glass front in frame with hinges and locking arrangement (18x24x6inch)

-

-

57990

... More
Supply and fixing of insulation mat for electrical purpose IS 15652/2006 Class C category II 100mmx3mm Rating AC(RMS): 33KV

-

-

934050

... More
Supply and fixing of portable fire fighting equipment (ISI marked Fire extinguisher Dry chemichel powder 6 KG )

-

-

90120

... More
Supply and fixing of portable fire fighting equipment ( ISI marked Fire extinguisher CO2 type 10KG) 041

-

-

50040

... More
Supply and fixing of fire bucket 10Ltr 042

-

-

24222

... More
Supply and fixing of fire bucket stand 043

-

-

36849.15

... More
Supply and erection of name board for TSS/SP/SSP 044

-

-

26055

... More
Supply and erection of Availability based tariff (ABT) Energy meter of Make secure Model Apex-150/100 or equivalent as per suitability for Odisha/Andhra Region

-

-

809010

... More
Supply and erection of 132KV/110V/15VA potential transformer 0.2 Class as per RDSO Spec 047

-

-

4223412

... More
Supply erection of data concentrator unit (DCU) along with software to synchronise SLDC System 049

-

-

778569

... More
Supply and erection of Industrial Ethernet switch (Type-A) as per specifcation 050

-

-

1264410

... More
Supply & erection of GPRS/GSM modem (external) as per specification 051

-

-

132108

... More
Supply erection testing and commissioning of on line monitoring system (Telemetry) including software, hardware real time data transfer from TSS to SLDC and RCC 053

-

-

52

... More
Dismantling of Earthing Blade Assembly for 132 kV Double Pole Isolators (Manually Operated). 063

-

-

17435.25

... More
Dismantling of 42 kV/120 kV Lighting Arrestor Assembly. 064

-

-

24226.02

... More
Dismantling of 25 kV SP Isolator Assembly. 065

-

-

38205

... More
Dismantling of 25 kV DP Isolator Assembly. 066

-

-

130533.75

... More
Dismantling of 25 kV/132 kV PT. 067

-

-

93683.2

... More
Dismantling of 25 kV/132 kV Support Insulator. 068

-

-

49506.4

... More
Dismantling of AL Busbar all size 069

-

-

54885

... More
Dismantling of ACSR Conductor with hardware etc. 070

-

-

3512

... More
Dismantling of Various Types of AL Terminal Connectors/Junctions 071

-

-

37472

... More
Dismantling of Various sizes of cables 072

-

-

175600

... More
Dismantling of Battery set 110v, 200/40AH with stand etc. 073

-

-

42574.5

... More
Dismantling of Various types of Jumpers. 074

-

-

27442.5

... More
Dismantling of Battery charger 100v, 200AH/40AH. 075

-

-

12241.5

... More
Dismantling of 25kV/132kV Current Transformer Assembly. 076

-

-

21603.6

... More
Dismantling of 25kV/132kV CB & Interruptors. 077

-

-

643297.71

... More
Dismantling of 25kV, 10KVA/25kVA Ats 078

-

-

110944

... More
Dismantling of 25kV Drop out fuse set. 079

-

-

10445.6

... More
Dismantling of Fencing panels and gate with anticlimbing device with fastners. 080

-

-

296425

... More
Retrival of Fencing upright and mast 081

-

-

1726987.5

... More
Retrival of Gantry Mast 082

-

-

609525

... More
Dismantling of Shunt Capacitor bank 083

-

-

195403.59

... More
Dismantling of Control relay panel

-

-

84

... More
Dismantling and shifting of Traction Power Transformer with Associated equipments from the existing bay and keeping at suitable place in substation as directed by the Engineer in Charge.

-

-

616781.58



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.