East Coast Railway Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 1,30,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
ST-SBP-TENDER-2024-15-SAMBALPUR DIVISION-S AND T/ECORTender No
ST-SBP-TENDER-2024-15Tender Authority
East Coast Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply 2T VF transformer with impedence ration of 470:1120 as per RDSO Spec no. IRS/TC- 76/2000. Materials are to be procured from RDSO approved source. Warranty- 01 year. Sample is to be approved before bulk supply.Inspection by representative of Sr.DSTE/SBP.
100
826
82600
Supply of 6 pin Emergency socket flat type as per IRS TC 42/20 version 1 or latest. Inspection by representative of Sr.DSTE/SBP..
100
163
16300
Supply of microphone suitable for 25 Watt VHF set. Make-Liesheng/HYT/Sanchar similar, Model No TM610 or similar. Inspection by representative of Sr.DSTE/SBP
20
1250
25000
Supply of wired supercardioid handheld microphone having frequency response 20-20000Hz, Equivalent noise level-0 db. Make- Ahuja, Model-PRO+ 3400 or similar. Inspection by representative of Sr.DSTE/SBP.
10
5066
50660
Supply of Master Telephone as per RDSO Specification No. RDSO/SPN/TC/51-2021 Rev. 1.0 or latest. Warranty period should be 30 months from the date of supply. Inspection by representative of Sr.DSTE/SBP.
10
46161
461616
Supply of Gate telephone as per RDSO Specification No. RDSO/SPN/TC/51-2021 Rev. 1.0 or latest. Warranty period should be 30 months from the date of supply.Inspection by representative of Sr.DSTE/SBP.
40
5251
210040
Supply of Centralised Power Supply System along with MF Batteries for Electronic LC Gate 10 Telephone System with surge protection arrangements as per RDSO Specification No. RDSO/SPN/TC/51-2021 Rev. 1.0 or latest. Warranty period should be 30 months from the date of supply.Inspection by representative of Sr.DSTE/SBP.
10
7080
70800
Supply of Magneto Telephone Desk type to Specification No. IRS: TC-36/97 amd 2. or IRS:TC 79/2000 Amdt. 4 as per Railway requirment. Inspection by the Representative of Sr.DSTE/SBP.
40
7317
292680
Supply of Universal Wayside DTMF Control Telephone 2W/4W as per RDSO specification NO.IRS- TC-82/2005 WITH AMENDMENT No.3 or Latest. Inspection by the Representative of Sr.DSTE/SBP.
100
10147
1014700
Supply of 120 inch (Diagonally) Motorised Projector Screen suitable for Office Meeting, Exhibitions, 13 presentations, displaying videos, photos etc. The Motor should work through remote control (Remote control with battery is to be supplied by the tenderar). It should be suitable for both Wall & Stand mount. Inspection by representative of Sr.DSTE/SBP.
2
11999
23998
Supply of optical fibre termination box for 2x24 fiber armoured cable complete with all accessories with all accessories with the fixing arrangement inside the equipment cubicle to accommodate all the fibers as per Specn No. DOT-G/TB/01/01. Inspection by representative of Sr.DSTE/SBP.
20
4909
98180
Supply of 12 port Rack mountable Optic Fiber Patch Panel wit SC connector loaded. Make D-Link,, Digilink, Walltech or similar. Inspection by representative of Sr.DSTE/SBP.
20
2100
42000
"Excavation of trenches of depth and width detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables la id in trench and backfilling, ramming, 1 consolidation of soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found."
-
-
1174156
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split 2 RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.
300
335
100500
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and width 0.3 Mts. at the 3 bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.
200
255
51000
"Trenching and fixing of G.I. pipes of different sizes/DWC pipes in hard rocky area up to a depth of 0.3 M to 0.6 M or at places as per instruction of site Engineer and concreting [1 : 3 : 6] up to height of 100 mm 4 above the pipes. G.I. pipes with the socket/ DWC pipes shall be supplied by the Railway. All other materials required for the works shall be supplied by the contractor. Note: [1] In case of girder bridges, G.I. pipes shall be suitably clamped by the contractor as advised by the site Engineer. Clamps shall be supplied by the contractor. [2] The work including excavation of trenches in hard rock area up to a depth of 0.3 M to 0.6 M and back filling, ramming after completion of work where ever required. [3] In case of concrete bridges clearing of ballast for laying of pipes and re arranging the Railway ballast after completion of work shall be done by the contractor. "
20
533
10660
Laying of Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from 5 the stores to work site and transportation of empty cable drums with left over cables from site to the stores at . The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.
17
24389
414613
Transportation, excavation of pit, casting of foundation, plastering and erection of Steel Apparatus case (Half size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/Con/BBS/92/90. This includes earth work and/or masonry work 6 required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock only. Tenderer shall supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet [6mm thickness], wood plank board of good quality [minimum 3/4" thick, cement and any other materials that are required for the work at his own cost. Contractor has to transport all the materials from store at his own cost to the work site. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources.
30
9742
292260
"Supply, transportation, installation, testing and commissioning of earth electrode (make TATA or Jindal medium gauge as per Rly. practice) as per ECoR Drg. No. Con/SK/T/9 , construction of cement enclosure as per ECoR Drg. No.CON/SK/T/9A given in Annexure-Y and drawl of 6 SWG wire or 2 Nos. of 8 SWG wires or 7 Signalling cable if given by Railways in place of 6/8 SWG wire/s, from earth electrode to place advised by the site Engineer including fixing and soldering of lugs and measuring, painting of the earth resistance etc. Inspection of earth electrode By Representative of Railway before use. Tenderer shall supply all materials such as cement, charcoal, salt, GI wire, lugs, 8X40 mm galvanized hex head bolts etc that are required for the work. NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint."
40
12306
492240
Transportation and fixing of perforated G.I. Pipes on bridges, culverts, drains or in trenches as per instruction of site Engineer with clamps at 1.5 mts. interval on steel girder bridges or at places advised by site 8 Engineer. This includes supplying of G.I. Pipes, 80/100/150 mm dia. Specn. No. IS:1239/2004, or latest medium gauge with threaded collars (Make -TATA /JINDAL) by tenderer. This also includes 100 mm thick concreting on GI pipes as required and instructed by site Engineer. The Bridge fixtures including 100 mm GI channel (minimum 1.2 mtr long) and all other materials required for the work shall be supplied by the tenderer.
30
2653
79590
Supply ,transportation & installation of Optical Fibre cable joint enclosure and splicing of OFC (24 Fibre) and testing. OFC spicing shall be done in presence of Railway Representative.
20
18027
360540
Transportation and jointing (straight through and derivation) of PIJF/Quad cables size TSF-IV as per Specn No IRS:TC-31/96 & IRS30/97. Jointing kits shall be supplied by Railway. All other materials shall be supplied by the tenderer
30
1591
47730
Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. 11 to 1.0 mtr a t places to be indicated by site Engineer for entering of cables inside the building. Only G.I pipes supplied by Railway and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer and also transportation of G.I Pipe from Store by the tenderer.
2
6108
12216
Transportation of HDPE pipe from the store to work site, laying of the same (With 4 mm nylon 12 rope, pre inserted inside the HDPE pipe) in excavated trench/ already laid GI/ RCC pipe / tubes, jointing, leveling and end sealing the pipes, HDPE pipe, couplers and end caps shall be supplied by Railway, Nylon rope shall be supplied by the contractor.
1
15746
15746
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through13 the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. Atinaccessible places wheremechanised laying is not possible,the cable is to be laid manually bypulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.
1
25563
25563
Supply, transportation, and installation of RCC joint chamber with two piece top cover and bottom 14 cover with hole for drainage and cable entry as per drawing attached in Section-H. This includes trenching for joint pit, back filling and ramming of pit after placing the joint closure and cable loop in the chamber without causing damage to the same and consolidation of soil as well as disposal of excess soil.
25
11156
278900
Supply ,transportation & fixing of different size of good quality PVC casing/pipes (ISI marked) as required by Railway at site for fixing or clamping with accessories like bands, clamps, screw etc.
100
32
3200
Transportation & laying of CAT-6 cable, OFC, Speaker cable & power cable in PVC conduit pipes.
100
3
350
Transportation of all sorts of Railway Signal & Telecom materials from/to any place in India to/from 17 Railway Stores / Any other store depot including loading, unloading and stacking the same at specified places as directed by the representative of Railway. The rate includes lead, lift, ascent, descent, all taxes, royalty, labour, tools and plants etc. complete.
-
-
73500
Hiring of JCB machine (in good condition) for leveling and dressing ground/dismantling structures 1 including disposal of debris through dumpers etc. with contractor's labour, JCB machine, machine operator, fuel etc. The contractor shall arrange road permit for vehicle for all the states of operation as per instruction of engineer-in-charge and vehicle shall not be more than three years old. payment shall be made for actual working hours at site.
20
858
17169.8
Supply, fitting & fixing of ply board 19mm thick for cupboard, partition wall etc. Inspection by Representative of Railway.
60
1459
87562.2
Repairing of Power Supply Cards/modules of STM-1 Equipments of M/s Tejas Make.Testing of the cards after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
5
9792
48960
Repairing of Power Supply Cards/modules of Primary Digital Drop Insert Multiplexer confirming to 4 RDSO Specification NO. IRS-TC-68/04 with ammendment if any. Testing of the cards after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
10
5072
50728
Repairing of Network Interface Cards/modules of Primary Digital Drop Insert Multiplexer confirming 5 to RDSO Specification No. IRS-TC- 68/04 with ammendment if any. Testing of the cards after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
5
4600
23001
Repairing of Voice Cards (Exchange Interface Card - 4 circuits/card)/modules of Primary Digital 6 Drop Insert Multiplexer confirming to RDSO Specification No. IRS-TC- 68/04 with ammendment if any Testing of the card after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
2
6341
12683.8
Repairing of Voice Cards (E& M Interface Card - 4 circuits/card )/modules of Primary Digital Drop 7 Insert Multiplexer confirming to RDSO Specification No. IRS-TC- 68/04 with ammendment if any. Testing of the card after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
5
5878
29391
Repairing of Voice Card (Subs/Hotline Interface Card - 4 circuits/card)/modules of Primary Digital Drop Insert Multiplexer confirming to RDSO Specification No. IRS-TC- 68/04 with ammendment if any. Testing of the card after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
5
7267
36338
Repairing of VHF Set 25 Watt of any make. Testing of the VHF set after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
5
2221
11106.75
Repairing of SMR MODULE of 48 Volt charger (Makre:- Amararaja, Puncom,Statcon). Testing of the SMR Module after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
5
2465
12325
Repairing of Universal control telephone. Testing of the card after repairing is to be done by an authorised representative of Sr.DSTE/SBP. A certificate of testing is to be produced during submission of Bill.
30
1000
30000
Splicing and /or termination of OFC cores as per directive of Railway Engineer (Both end). Splicing machine and other necessary materials to be arranged by the Contractor
100
225
22510
Painting & Lettering of emergency sockets & post including supply of black, white & red oxide of reputed brand and IS spec. Paint to be applied in two coats. Rusted portion, if any, to be rubbed out and applied with red oxide after which two coats of necessary paint will be applied.
170
576
97920
Painting with aluminium paint of approved brand and manufacture to give an even shade one or more coats of Location Box(outside) including supply of Aluminium paint.
1500
30
46035