Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 18,800Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Comprehensive Annual Maintenance Contract For Electrical Maintenance For 2 Years At Cmpdi, Ri Vii Talcher Exploration Camp
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CMPDI_312600_1Bid Award Id
ViewTender No
CMPDI/RIVII/BBSR/ENM/2024/1562Tender Authority
Central Mine Planning And Design Institute Limited ViewPurchaser Address
-Website
http://coalindiatenders.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/steel tubular/ rail pole etc. as required.
8
-
-
Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
12
-
-
Supplying and erection of 100 mm X 80 mm pin insulator with G. I. spindle, nuts and straps etc. as required .
32
-
-
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm
diameter including binding etc. as required.
50
-
-
Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with 2x4 sq.mm + 1x4 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
100
-
-
Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with 2x6 sq.mm + 1x6 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
100
-
-
Supply of 25 mm dia ISI marked PVC conduit
200
-
-
Circuit/sub-main wiring in PVC conduit : Wiring for circuit/submain wiring alongwith earth wire with 2x10 sq.mm + 1x6 sq.mm of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
50
-
-
Supplying and drawing of 3x1.5 sq.mm FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required.
50
-
-
Supplying and drawing of 3x2.5 sq.mm FR PVC insulated copper conductor single core cable in the existing surface/recessed steel / PVC conduit as required.
50
-
-
Supplying and fixing of 5/6 amps switch on the existing switch box/cover including connections etc. as required
75
-
-
Supplying and fixing Bell push switch on the existing switch box/cover including connections etc. as required
25
-
-
Supplying and fixing of call bell/buzzer suitable for single phase, 230 volts, complete as required.
10
-
-
Wiring for light point / fan point/exhaust fan /call bell point with 1.5 sqmm FR PVC insulated,copper conductor, single core cable in surface/recessed steel / PVC conduit , with piano type switch , phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required. Group A - 3 mtrs
10
-
-
Wiring for light point / fan point/exhaust fan /call bell point with 1.5 sqmm FR PVC insulated,copper conductor, single core cable in surface/recessed steel / PVC conduit , with piano type switch , phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required. Group B - 4 mtrs
10
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
10
-
-
Supply and fixing 5A to 32 A rating 240/415V ,10 kA "C"- curve miniature circuit breaker suitable for inductive load for Single pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required.
20
-
-
Supply and fixing 5A to 32 A rating 240/415V ,10 kA "C"- curve miniature circuit breaker suitable for inductive load for Double pole in the existing MCB DBs complete with connections , testing , commissioning etc. as required.
10
-
-
Supply and fixing 5A to 32 A rating 240/415V ,10 kA "C"- curve miniature circuit breaker suitable for inductive load for Triple Pole and Neutral in the existing MCB DBs complete with connections , testing , commissioning etc. as required.
5
-
-
Providing and fixing 50 kA, 400 amps four pole rating and breaking capacity and pole MCCB with thermomagnatic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel ,making connections etc. as required .
2
-
-
Earthing with GI earth plate 600mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required
6
-
-
Supply of aluminium binding wire
4
-
-
Supply and fixing phase separator in overhead line
20
-
-
Supply of 55 mm2 All alloy aluminum conductor AAAC
1
-
-
Trimming of tree branches near the overhead line in camp premises.
1
-
-
Supply and fixing of 415V, 63A, with 3 PP, 'C' CURVE,10kA breaking capacity TPN MCB (Make-L&T / ABB / HAVELLS / SCHNEIDER / CONTROL & SWITCHGEAR COMPANY / STANDARD OR EQUIVALENT)
3
-
-
Supply and fixing of 10 watt LED tube light batten (make wipro ,bajaj ,philips or equivelent.)
50
-
-
Supply and fixing of 20 watt LED tube light batten (make wipro ,bajaj ,philips or equivelent.)
75
-
-
Supply and fixing of R06 type (AA), 1.5V Battery
25
-
-
Supply and fixing of R03 type(AAA), 1.5V Battery
25
-
-
Supply and fixing of 12 watt LED indoor light fitting (make wipro, BAJAJ / PHILIPS / HAVELLS / CROMPTON/ OR EQUIVALENT ).
25
-
-
Supply and fixing of 4 pole 40 Amp.,415 volts onload changeover switch with enclosure
1
-
-
Supply and fixing of PVC board of 7"x4" sizes with backelite sheet on top.
50
-
-
Supply and fixing of PVC board of 8"x6" sizes with backelite sheet on top.
50
-
-
Supply and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4 core 10 sq.mm on wall surface as required. (Make - UNIVERSAL CABLES/ NICCO/ HAVELLS/ SKYTONE/ KEI INDUSTRIES/ POLYCAB /OR EQUIVALENT).
15
-
-
Supply and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3 1/2 core 25 sq.mm on wall surface as required. (Make - UNIVERSAL CABLES/ NICCO/ HAVELLS/ SKYTONE/ KEI INDUSTRIES/ POLYCAB /OR EQUIVALENT).
15
-
-
Supplyand Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3 1/2 core 70 sq.mm on wall surface as required. (Make - UNIVERSAL CABLES/ NICCO/ HAVELLS/ SKYTONE/ KEI INDUSTRIES/ POLYCAB /OR EQUIVALENT).
10
-
-
Supply and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3 1/2 core 120 sq.mm on wall surface as required. (Make - UNIVERSAL CABLES/ NICCO/ HAVELLS/ SKYTONE/ KEI INDUSTRIES/ POLYCAB /OR EQUIVALENT).
10
-
-
Supply and fixiSupply and fixing of 24/25 W LED street light fitting complete with LED lamps, driver unit in existing GI bracket and clamping arrangement. (make wipro ,philps , HPL ,or equivelent.)
10
-
-
Supply and fixing of bolted fuse link (16 Amp. To 32 Amp)
5
-
-
Supply and fixing of fuse holders 20 Amp.
5
-
-
Supply and fixing of fuse holders 32 Amp.
5
-
-
Electrician for maintenance - comprising of Electrical fault rectification, Generator operation, substation manning, lift operation etc. ( detail scope provided in NIT) by deployment of two electrician(one for office and one for colony) with valid electrical licence per shift for three shifts per day .
24
-
-
Repair of exhaust fan (rewinding, bearing )
3
-
-
Repair of wall mounted fan (rewinding, bearing )
3
-
-
Repair of pedestal fan (rewinding, bearing )
3
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Rewinding work
2
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - lathe work for shaft repair
1
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Motor Bush
1
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump impeller
6
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump Diffuser
6
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump shaft
1
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Pump coupling
1
-
-
Reparing and servicing of 3 phase 2 HP submersible pumpset installed in CMPDI Campus - Installation
1
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Air Filter
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Fuel filter pre element
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Element fuel Micro Filter
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Lub Oil Filter element
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Pre-mix 10 ltr Pack
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Lub oil 20Ltr Pack
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Coggled belt
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - PDC rocker cover gasket
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - packing & forwarding charges
2
-
-
Servicing and Maintenance of DG set 1 x 25 KVA - Servicing of DG set such as replacement of spares, tuning and adjustment & testing
2
-
-
Repairing of 11/.415 kV Transformer - Topping-up of transformer with new transformer oil (Chargable as per actual )
50
-
-
Repairing/servicing of 2 Te. Split AC - AC service charge
3
-
-
Repairing/servicing of 2 Te. Split AC - Single pole contactor for outdoor unit
1
-
-
Repairing/servicing of 2 Te. Split AC - Gas Charge
2
-
-
Repairing/servicing of 2 Te. Split AC - Capacitor for Outdoor unit
2
-
-
Repairing/servicing of 2 Te. Split AC - Fan Motor
1
-
-
Providing, fixing new battery along with buy back of old battery of rating 12V 120 AH for DG set
1
-
-