Capital Region Urban Transport Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Capital Region Urban Transport - CRUT Tender

Electrical and Electronics
Eprocure
Opening Date21 Apr 2022
Closing Date30 Apr 2022
Tender Amount₹ 15,55,134 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
AB Switch mounting channel 75x40x4.8mm,7.14Kg/mtr, each channel length 3 mtr, 2 nos channel required= (7.14x3x2)

42.84

-

105.76

... More
AB Switch side support channel 100x50x6mm,9.56Kg/mtr, each channel length 0.35 mtr, 2 nos channel required= (9.56x2x0.35)

6.69

-

105.76

... More
Channel support for down pipe 75x40x4.8mm,7.14kg/mtr each channel length 0.8 mtr, 1 nos channel required=(7.14x0.8x1)

5.71

-

105.76

... More
Double pole belting channel 75x40x4.8mm,7.14kg/mtr,each channel length 3 mtr,4nos channel required=(7.14x3x4)

85.68

-

105.76

... More
50x50x6mm GI Bracing Angle,4.5kg/mtr, each angle length 3.512 mtr,4 nos angle required=(4.5x3.512x4)

63.22

-

105.76

... More
Danger Plate 2 nos

2

-

112.81

... More
Back clamp for danger plate 25x3mm flat,0.59 kg/mtr, flat of 0.510 mtr length 2 nos=(2x0.59x0.510)

0.6

-

105.76

... More
H.T.Stay clamp, 50x8mm flat 3.14 kh/mtr,0.511 mtr length, 2 nos qty required (1pair)

2

-

176.26

... More
H.T.Stay set (Complete)

2

-

1480.61

... More
H.T.Stay insulator type-C(2 Nos)

2

-

70.51

... More
7/10 SWG Stay wire 15kg/stay

30

-

105.76

... More
GI Pipe Earthing 40mm, 3 mtr long

2

-

1480.61

... More
50x6mm GI Flat for earthing, 2.36kg/mtr,(12.5mtr for L.A,3 Mtr for AB Switch body, 2.5mtr for mesh formation and 2.5 mtr for raising)= 20.5x2.36)

48.38

-

105.76

... More
GI barbed wire anticlimbing device 3 kg per support, 2 nos qty required=(2x3kg)

6

-

112.81

... More
Back clamp for anticlimbing device 25x3mm flat,0.59 kg/mtr, flat of 0.510 mtr length 8 nos=(8x0.59x0.510)

2.41

-

105.76

... More
Lightning Arrester (12KV,10KA)(Staion Class, class-2)

3

-

5005.86

... More
AB Switch (11KV,400A,3 Pole,50Hz)

1

-

16709.69

... More
11KV pin insulator polymer

3

-

282.02

... More
H W fitting (B&S)70KN 4 bolt

6

-

493.54

... More
Disc insulator (B&S) 70 KN Polymer

6

-

1621.62

... More
PG Clamp for 80 sq mm AAA conductor

6

-

747.35

... More
GI Nut,bolt & washer of different sizes (13.718 kg each 6 pole)

13.72

-

109.99

... More
Black paint

1

-

310.22

... More
Yellow colour paint for Background

2

-

310.22

... More
Civil & Services Fixing of complete 11KV line complete stay set includes 1. Turn Buckle Assembly, 2. Stay Rod & Stay plate, 3. Stay Insulator,4. Stay wire,5. Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5 Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & standard.

2

-

2250

... More
Concreting ratio 1:1.5:3 (500mmx500mmx1800mm)=0.45 Cu.mtr

0.9

-

6500

... More
Couping ration 1:1.5:3 with dimension (500x500x450)=0.1125 Cu mtr

0.23

-

6500

... More
Installation of Earth pit,charcoal,salt etc including construction of earthing chamber (Size: 2'x2') and RCC slab cover

2

-

2407

... More
Construction of 11KV O/H line of length 10 mtr in 80mm2 AAAC Conductor. Straight Cross Arm 100x50x6mm,9.56 kg/mtr, each channel length 1.2 mtr,4 nos channel required = (4x9.56x1.2)

45.89

-

105.76

... More
Fish plate 50x6mm 2.36 kg/mtr,each 0.280 mtr length, 16 nos required=(16x2.36x0.280)

10.57

-

105.76

... More
Straight Cross Arm 100x50x6mm,9.56 kg/mtr, each channel length 0.306 mtr,4 nos channel required = (4x9.56x0.306)

11.7

-

105.76

... More
Danger Plate 1 nos

1

-

112.81

... More
Black clamp for danger plate 25x3mm flat,0.59kg/mtr flat of 0.510mtr length 1 nos= (1x0.59x0.510)

0.3

-

105.76

... More
GI barbed wire anticlimbing device 3 kg per support

3

-

112.81

... More
Black clamp for anticlimbing device 25x3mm flat,0.59kg/mtr flat of 0.510mtr length 4 nos= (4x0.59x0.510)

1.2

-

105.76

... More
11KV pin insulator polymer

5

-

282.02

... More
H W fitting (B&S)70KN 3 bolt

9

-

493.54

... More
Disc insulator (B&S) 70 KN Polymer

9

-

1621.62

... More
Earthing support (Coil type)

1

-

234.08

... More
No-8 GI Wire(Dia 4.6mm) 0.131 kg/mtr-2 mtr for connecting pole with coil earthing

0.26

-

105.76

... More
PG Clamp for 80 sq mm AAA conductor

12

-

747.35

... More
GI Nut,bolt & washer of different sizes (7.433 kg each Cut pole)

7.43

-

109.99

... More
80 mm2 AAAC

0.03

-

60634.3

... More
Installation of 11KV DP for HT Metering Unit WPB 160X152(11Mtr.long,30.44 Kg/Mtr)

2

-

31687.76

... More
Top channel 100x50x6mm, 9.56 Kg/Mtr,each channel length 3 mtr, 2 nos channel required=(2x9.56x3)

57.36

-

105.76

... More
Fish plate 50x6mm 2.36 kg/mtr,each 0.280 mtr length, 6 nos required=(6x2.36x0.280)

3.96

-

105.76

... More
AB Switch mounting channel 75x40x4.8mm,7.14Kg/mtr, each channel length 3 mtr, 2 nos channel required= (7.14x3x2)

42.84

-

105.76

... More
HT MU Mounting channel 75x40x4.8mm, 7.14kg/mtr, each channel length 3 mtr, 2 nos channel required(7.14x3x2)

42.84

-

105.76

... More
Cantilever GI Channel for supporting for HT MU 50X50X6mm (1.0mtrs long,2 nos)4.5 kg per meter

9

-

105.76

... More
Angle for cantilever arrangement for HT MU 50X50X6-2 mtr each 2nos (4.5 kg per mtr)

18

-

105.76

... More
AB Switch side support channel 100x50x6mm,9.56Kg/mtr, each channel length 0.35 mtr, 2 nos channel required= (9.56x2x0.35)

6.69

-

105.76

... More
Channel support for down pipe 75x40x4.8mm,7.14kg/mtr each channel length 0.8 mtr, 1 nos channel required=(7.14x0.8x1)

5.71

-

105.76

... More
Double pole belting channel 75x40x4.8mm,7.14kg/mtr,each channel length 3 mtr,4nos channel required=(7.14x3x4)

42.84

-

105.76

... More
50x50x6mm GI Bracing Angle,4.5kg/mtr, each angle length 3.512 mtr,4 nos angle required=(4.5x3.512x4)

31.61

-

105.76

... More
Danger Plate 2 nos

2

-

112.81

... More
Back clamp for danger plate 25x3mm flat,0.59 kg/mtr, flat of 0.510 mtr length 2 nos=(2x0.59x0.510)

0.6

-

105.76

... More
55mm2 All Alloy Aluminum conductor (AAAC)-PVC Insulated for jumpering.

0.02

-

66920

... More
H.T.Stay clamp, 50x8mm flat 3.14 kh/mtr,0.511 mtr length, 2 nos qty required (1pair)

2

-

176.26

... More
H.T.Stay set (Complete)

2

-

1480.61

... More
H.T.Stay insulator type-C

2

-

70.51

... More
7/10 SWG Stay wire 15kg/stay

30

-

105.76

... More
GI Pipe Earthing 40mm, 3 mtr long

2

-

1480.61

... More
50x6mm GI Flat for earthing, 2.36kg/mtr,(12.5mtr for L.A,3 Mtr for AB Switch body, 2.5mtr for mesh formation and 2.5 mtr for raising)= 20.5x2.36)

48.38

-

105.76

... More
GI barbed wire anticlimbing device 3 kg per support, 2 nos qty required=(2x3kg)

6

-

112.81

... More
Back clamp for anticlimbing device 25x3mm flat,0.59 kg/mtr, flat of 0.510 mtr length 8 nos=(8x0.59x0.510)

2.41

-

105.76

... More
Lightning Arrester (11KV,10KA)(Staion Class, class-2)

3

-

5005.86

... More
AB Switch (11KV,200A,3 Pole,50Hz)

1

-

10364.24

... More
11KV pin insulator polymer

3

-

282.02

... More
H W fitting (B&S)70KN 3 bolt

6

-

493.54

... More
Disc insulator (B&S) 70 KN Polymer

6

-

1621.62

... More
PG Clamp for 55 sq mm AAA conductor

6

-

676.85

... More
GI Nut,bolt & washer of different sizes (13.718 kg each DP with AB Switch)

13.72

-

109.99

... More
Black paint

1

-

310.22

... More
Yellow colour paint for Background

2

-

310.22

... More
Civil & Services Fixing of complete 11KV line complete stay set includes 1. Turn Buckle Assembly, 2. Stay Rod & Stay plate, 3. Stay Insulator,4. Stay wire,5. Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5 Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & standard.

2

-

2250

... More
Concreting ratio 1:1.5:3 (500mmx500mmx1800mm)=0.45 Cu.mtr

0.9

-

6500

... More
Couping ration 1:1.5:3 with dimension (500x500x450)=0.1125 Cu mtr

0.23

-

6500

... More
Installation of Earth pit,charcoal,salt etc including construction of earthing chamber (Size: 2'x2') and RCC slab cover

2

-

2407

... More
Installation of 11/0.4KV,500KVA DSS. HG/DO Fuse Mounting Channel 75x40x4.8mm GI Channel (3000mm long) (7.14kg/mtr,2 nos) (Each 2x3.000x7.14=39.98 kg)

42.84

-

105.76

... More
Cantilever Support Channel 75x40x4.8mm GI Channel (810 mm long, 2 nos) (7.14kg/mtr,2 nos) (Each 2x0.810x7.14=11.57kg)

11.57

-

105.76

... More
Cantilever Support Angle 50x50x6mm GI (1282 mm long)(4.5kg/mtr,2 nos)(Each 2x1.282x4.5=11.54kg)

11.54

-

105.76

... More
50x6mm GI Flat for earthing, 2.36kg/mtr,(2.5x7mtr for for mesh formation,12 mtr for LA and 2.5 mtr for raising, 11 mtr for AB Switch, 2.8 mtr for HG Fuse, 5x2mtr for DTR Nutral,(1.3+4.5)mtr for DTR Body,0.500 mtr for LTDB & AB Switch operating handle, 3 mtr for fencing)(Each 65.6x2.36=154.81kg)

106.44

-

105.76

... More
500KVA,11/0.4KV (AL) Transformer with Tap Changer BIS Energy Level II

1

-

817858

... More
LT Distribution Box with MCCB,Aluminum busbar for 3 bay with kit kat fuse for 500KVA S/S.

1

-

137287.34

... More
55mm2 All Alloy Aluminum conductor (AAAC)-PVC Insulated(50mtr each dtr.)

0.04

-

66920

... More
1C X 400mm2 LT XLPE Cable(Un-Armoured)

180

-

429.79

... More
H.G.Fuse (11KV 200A,3 Pole)

1

-

8629.81

... More
40mm Nominal bore GI Pipe (medium gauge)earthing device with 3 mtr long

5

-

1480.61

... More
GI Nut,bolts of Assorted size(25kg/DSS DP)

11.28

-

109.99

... More
Name plate

1

-

112.81

... More
Civil & Services Installation of Earth pit,charcoal,salt etc including construction of earthing chamber (Size: 2'x2') and RCC slab cover

5

-

2407

... More
LTDB Plinth

1

-

3000

... More
DTR Plinth

1

-

25000

... More
Installation of Boundary around sub-station & D.P structure with spreading of metal and sand inside sub-station premises with fixing of MS Grill gate.

1

-

57909.45



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.