Bharat Sanchar Nigam Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Bharat Sanchar Nigam Limited - BSNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date10 Sep 2024
Tender Amount₹ 5,08,477
Costs
EMD
₹ 10,170Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Attending Mv/lt Electrical Faults And Repairing Of Ei And Fans And Service Connection Cables Etc. For Various Tes/bts Of Baripada Ssa Under Balasore Ba . (for The Year 2024-25)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_206754_1Bid Award Id
ViewTender No
NIT No- 19/BSNL/ED/CTC/2024-25Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bsnl.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Distance above 100 Kms and up to 200 Kms from Baripada
5
-
-
Replacement of the faulty and burn out MCBs, Isolators etc. by new ones of following ratings MCBs and Isolators ISI marked as per IEC 60947-3 /MCBs 10 kA , C- Curve as per IEC 60947-2 in existing MCBDBs i/c connection testing etc. as required.(Make-Legrand / L&T / Schneider Electric / Siemens/Havells )
-
-
-
100Amps 4 pole Isolator
3
-
-
63Amps 4 pole Isolator
3
-
-
63Amps 4 pole MCB
3
-
-
63 Amps DP MCB
3
-
-
32Amps 3 pole MCB
3
-
-
40Amps DP Isolator
5
-
-
40Amps DP MCB
3
-
-
6-32A SPMCB
10
-
-
S/F of weather proof Cut out box made of MS sheet with hinged door, cutting, fabricating painting with two coats of primer & synthetic enamel paint, fixing on existing PSC pole/wall with suitable nut bolts, etc i/c S/F of 1 no neutral link etc as required.
1
-
-
Replacement of faulty and damaged ceiling fan by new one of following size of Havells /Usha / Crompton/SS Make suitable for operation on 240 volts AC, 50Hz i/c fixing and connection etc. as required.
-
-
-
a) 1200 mm ceiling fan
1
-
-
Replacement of the faulty and burn out Fuse links by new ones of following ratings i/c connection testing etc. as required.(Make-Legrand / L&T / Schneider Electric / Siemens/Havells )
-
-
-
32 Amps 415V HRC Fuse links- Cylindrical type (L&T/Havells)
6
-
-
63 Amps 415V HRC Fuse links- Cylindrical type (L&T/Havells)
6
-
-
32 Amps 415V HRC Fuse links-Bolted type (L&T/Havells)
3
-
-
63 Amps 415V HRC Fuse links- Bolted type (L&T/Havells)
3
-
-
100 Amps 415V HRC Fuse links- DIN type (L&T/Havells)
3
-
-
125 Amps 415V HRC Fuse links- DIN type (L&T/Havells)
3
-
-
62 Amps 415V Porcelain Fuse unit
6
-
-
100 Amps 415V Porcelain Fuse unit
3
-
-
Replacement of the following burnt out/damaged cable/wires/lugs/sockets etc. by new one of following types, sizes and ratings PVC insulated FRLS copper conductor single core stranded flexible cable i/c laying / drawing in existing conduit/pipe, connection, testing etc. as required.
-
-
-
25sqmm with copper socketing
10
-
-
16sqmm with copper socketing
10
-
-
10sqmm with copper socketing
20
-
-
6sqmm
20
-
-
4sqmm
30
-
-
1.5sqmm
50
-
-
Replacement of the burnt out cables/wirings by the following sizes PVC insulated & PVC sheathed copper conductor multicore cable i/c fixing/laying on wall/ceiling with C clamps etc. as required.
-
-
-
3 coreX2.5sqmm
20
-
-
4 coreX2.5sqmm
15
-
-
3 coreX4.0 sqmm
15
-
-
Supply of the following sizes PVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables.
-
-
-
2 core 6 sqmm
30
-
-
4 core 10 sqmm
30
-
-
4 core 16 sqmm
50
-
-
4 core 25 sqmm
30
-
-
3.5 core 50sqmm
20
-
-
Replacement of faulty service connection cables by new one of 2 core X4sqmm PVC insulated and PVC sheathed Aluminium conductor weather proof cable etc. as required.
50
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
Up to 35sqmm
30
-
-
Above 35 sq. mm and up to 95 sq. mm
5
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Up to 35sqmm
50
-
-
Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
5
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
-
-
-
Up to 35sqmm
30
-
-
Above 35 sq. mm and up to 95 sq. mm
5
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm in the existing Duct/Air as required.
-
-
-
Up to 35sqmm
30
-
-
Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
5
-
-
Replacement of damaged MV cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
4 X 16 sq. mm (28mm)
10
-
-
4 X 25 sq. mm (28mm)
2
-
-
3½ X 50 sq. mm (35mm)
2
-
-
Replacement of faulty SDFU switches by new ones of following ratings after dismantling the old defective ones, fixing, connection & testing etc. as required.
-
-
-
32 Amps 415 volts TPN SDFU with HRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) .
2
-
-
63 Amps 415 volts TPN SDFU with HRC fuses (open execution type).(Make: L&T FN type, /Havells / Siemens) .
2
-
-
100 Amps 415 volts TPN SDFU with DIN type HRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) .
1
-
-
125 Amps 415 volts TPN SDFU with DIN type HRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) .
1
-
-
Replacement of faulty SDFU switches by new ones of following ratings with specious sheet steel enclosure so that there will be no need of separate cable gland boxes, having terminal shrouds and phase barriers on both sides suitable for Cylindrical/DIN type HRC fuse links, confirming to IEC-60947-3, IS/IEC:60947-3, after dismantling the old defective ones, fixing, connection & testing etc. as required.
-
-
-
63 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses.(Make: L&T FN type, /Havells / Siemens) .
2
-
-
100 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&T FN type, /Havells / Siemens) .
1
-
-
125 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&T FN type, /Havells / Siemens) .
1
-
-
Replacement of faulty Change over switches by new ones of following ratings after dismantling the old defective ones, fixing, connection & testing etc. as required.
-
-
-
63Amp 4-pole on load change over switch open execution type (Make: HPL Socomec /Havells / L & T) .
1
-
-
125Amp 4-pole on load change over switch open execution type (Make: HPL Socomec /Havells / L & T) .
1
-
-
63Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) .
1
-
-
100Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) .
1
-
-
125Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) .
1
-
-
Replacement of faulty and damaged FTL fittings by new one of following ratings, LED Batten with polycarbonate/Aluminium body suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells /Phillips / Surya / Polycab / Crompton)
-
-
-
22W General purpose industrial compact batten suitable for Double LED Tube light with integral LED driver with single / double side connection options. (Make-Havells/Phillips/Bajaj/Wipro/Crompton)
2
-
-
Supply of the following electrical accessories/components for Electrical Light Fittings i/c testing etc. as required.
-
-
-
36 /40-watt Fluorescent Tube rods
100
-
-
36/40-watt electronic ballast for Fl. Tube fittings
20
-
-
Starter for Fl. Fittings
100
-
-
Driver with universal connector for LED light fittings (15watt/18watt)
5
-
-
Driver with universal connector for LED light fittings (24watt)
3
-
-
9 /10-watt LED Lamp (B22)
10
-
-
14/15-watt BC LED Lamp (B22/E27)
10
-
-
30-watt (B22/E27) LED lamp
2
-
-
20/22W Ultra bright LED Tube light with very high efficacy =115 lm/W & THD10% suitable for installation in existing tube light G13 lamp holders to give glare free light.
15
-
-
Replacement of the lamp holders/ceiling roses etc. by new ones of reputed makes etc. as required.
-
-
-
Angle/batten Holder
15
-
-
36/40 W Fl Tube light holder
50
-
-
36/40 W Fl Tube light starter holder
25
-
-
Ceiling Rose
30
-
-
5/6Amps 250 Volts 3 pin Plug top
5
-
-
15/16Amps 250 Volts 3 pin Plug top
5
-
-
Replacement of the defective switches/sockets/lamp holders/ call Bells etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)
-
-
-
6 /10 Amps 1 way modular type switch
10
-
-
16/20 Amps 1 way modular type switch
5
-
-
6 /10 Amps 1 way piano type switch
20
-
-
20 Amps 1 way piano type switch
5
-
-
6 /10 Amps 3pin modular type socket
10
-
-
16/5 Amps 6 pin modular type socket
5
-
-
6 Amps 3 pin piano type socket
5
-
-
16 Amps 3 pin piano type socket
5
-
-
Providing & fixing of following watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection suitable for operation on 230 volts, 50 HZ AC supply i/c fixing, connection and testing etc. as required. (Make : Philips/ Havells / Wipro / Osaram / Crompton / Bajaj).
-
-
-
25 Watt
2
-
-
45 Watt
2
-
-
Carry out repairing of Electrical Light Fittings by arranging qualified and trained man power and tools, tackles, ladders etc. i/c dismantling of defective/faulty components and fixing of new components i.e chokes, lamps, starters, interconnection wires, lamp holders etc. as required.
50
-
-
Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.
5
-
-
Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.
5
-
-
Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)
-
-
-
Stepped type Electronic Fan Regulator (Switch type)
5
-
-
Modular Fan Regulator (2 Modules)
5
-
-
Modular Fan Regulator (1 Module)
5
-
-
2.25 mfd 440 volts Capacitor for Ceiling Fan
20
-
-
Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS)
10
-
-
Ceiling Fan clamps heavy duty mild steel zinck golden colour with rubber (Shackle set)
10
-
-
Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent, reinstalling the same as required.
10
-
-
S/F of MCB protected Socket outlet 4 module with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps "C" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard)
3
-
-
Replacement of burn out Sockets/lugs of cables by new ones of following types and sizes i/c dismantling the burnt out portion of cables/wires, crimping/fixing of new sockets/lugs etc. (Dowell's / Comet / Hex Connect well / SS)
-
-
-
For 4X16sqmm Al Conductor Armoured cable
2
-
-
For 3.5/4X25/35sqmm Al Conductor Armoured cable
2
-
-
For 3.5X50/70sqmm Al Conductor Armoured cable
4
-
-
Supply of Hot pressed molded SMC Junction box, hinged double door type of following sizes suitable for application for fixing Electrical controls /switch gears/meters etc. with provision for cable entry/exit from bottom/side , locking arrangements including supply and fixing of 2nos 4 pole stud connectors, interconnections with suitable size single core PVC insulated copper conductor cable with copper sockets/lugs including fixing on existing pole / existing MS/GI angle stands etc. complete as required.
-
-
-
Size not less than 650mmX350mmX250mm (inside dimensions) (Make-Sintex model: SINTEX JB-6535/SS)
1
-
-
Size not less than 400mmX300mmX190mm (inside dimensions) (Make-Sintex model: SINTEX JB-4030/SS)
1
-
-
Making suitable angle base frame made of 40mmX40mmX5mm MS angle for installation of mentioned SMC junction / meter boxes , cutting, welding, fabricating, grouting the same on ground with required PCC work complete as required.
2
-
-
Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS)
2
-
-
Liaison with the Electricity DISCOMs for taking shutdown of LT/MV lines for checking, testing and replacement of faulty Service connection cable/Energy Meter/ Meter box/Feeder panel etc. and re energization of power supply after replacement of faulty components as above / removal of faults etc. complete as required.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements