Bharat Sanchar Nigam Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 7,005Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_213231_1Bid Award Id
ViewTender No
40/CE(C)/2024-25/BCD/CuttackTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bsnl.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge..
1
-
-
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :
-
-
-
100 mm dia pipe
64
-
-
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
138
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
15
-
-
Sub-Head : Earth Work
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
-
-
-
All kinds of soil.
4
-
-
Sub-Head : Concrete Work
-
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
1.5
-
-
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
-
-
-
1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1
-
-
1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 brickbats upto 40mm size).
2
-
-
Sub-Head : Reinforced Cement Concrete
-
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
0.6
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
2
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more.
60
-
-
Sub-Head : Masonry Work
-
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
16
-
-
Sub-Head : Flooring
-
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
40 mm thick with 20 mm nominal size stone aggregate
4
-
-
Sub-Head : Roofing
-
-
-
Making Khurras 45X45cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm mnominal size ), finished with 12 mm cement palster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement rounding the edges and making and finishing the outlet complete including dismantaling existing Khurra and disposal of the unserviciable material upto lead of 50 Metre
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
-
-
-
Single pushfit Coupler :
-
-
-
110mm
6
-
-
Single tee with door
-
-
-
110x110x110 mm
20
-
-
Bend 87.5°
-
-
-
110 mm bend
10
-
-
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
-
-
-
110 mm
30
-
-
Sub-Head : Water Proofing
-
-
-
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
10
-
-
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
-
-
-
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
-
-
-
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
-
-
-
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
-
-
-
Grading roof for water proofing treatment with
-
-
-
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
6
-
-
Sub-Head : Finishing
-
-
-
12 mm cement plaster of mix :
-
-
-
1:6 (1 cement: 6 coarse sand)
108
-
-
15 mm cement plaster on rough side of single or half brick wall of mix :
-
-
-
1:6 (1 cement: 6 coarse sand)
30
-
-
12 mm cement plaster finished with a floating coat of neat cement of mix :
-
-
-
1:4 (1 cement: 4 fine sand)
38
-
-
Finishing walls with water proofing cement paint of required shade :
-
-
-
New work (Two or more coats applied @ 3.84 kg/10 sqm).
150
-
-
Sub-Head : Repairs to Buildings
-
-
-
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
1
-
-
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
117
-
-
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge.
-
-
-
Internal Work- Exposed on wall
24
-
-
Sub-Head : Sanitary Installations
-
-
-
Providing and fixing white vitreous china water closet squatting pan (Indian type) :
-
-
-
Orissa pattern W.C. pan of size 580x440 mm
1
-
-
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
-
-
-
10 litre capacity - White
1
-
-
Sub-Head : Water Supply
-
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
-
-
-
20 mm nominal outer dia. Pipes.
4
-
-
25 mm nominal outer dia .Pipes.
8
-
-
40 mm nominal outer dia. Pipes.
12
-
-
Providing and fixing PTMT grating of approved quality and colour.
-
-
-
Circular type.
-
-
-
100 mm nominal dia.
3
-
-
Cutting holes up to 30x30 cm in walls including making good the same:
-
-
-
With common burnt clay F.P.S. (non modular) bricks.
20
-
-
Sub-Head : NEW TECHNOLOGIES AND MATERIALS
-
-
-
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
-
-
-
50 mm average thickness
2
-
-
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
-
-
-
Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make.
2
-
-
Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc. (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument)
-
-
-
50mm thick in Grade M 25 with cement content not less than 330 kg per cum
2
-
-
Sub-Head : MARKET RATED ITEMS
-
-
-
Deduct for taking into possession the unserviceable dismantled materials including carriage:
-
-
-
Dismantled damaged Gun metal gate valve 25mm to 40 mm.
6
-
-
GI / CI pipes with fittings
200
-
-
Providing and fixing double scaffolding system on the exterior side upto seven storey height made with best quality bamboo ballies 1.5 m centre to centre, horizontal and vertical ballies joining with best quality coir ropes, 38 mm thick local hard wood planks for working platform and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per direction of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding.
24
-
-
Engaging labour for cleaning of open surface drains of any size, roof, terrace, chajjas at any floor at any height including all T & P, removal of debrishes, sullage and disposal all complete as per direction of Engineer-in-charge.
8
-
-
Cleaning of drainage manholes alongwith connecting sewer lines including removing the soil, waste, sludge deposits, earth, rubbish etc. and disposal of same including flushing with sufficient water all complete as per direction of the Engineer -in- charge.
4
-
-
Providing and fixing CPVC Ball valve approved quality with handle in CPVC pipe line etc complete as per direction of Engineer-in-charge:
-
-
-
25 mm diameter
4
-
-
40 mm diameter
2
-
-
Providing and fixing CPVC Union in CPVC pipe line including cutting the pipe etc complete as per direction of Engineer-in-charge
-
-
-
25 mm diameter
4
-
-
40 mm diameter
2
-
-
Extra for providing and mixing liquid water proofing compound of DR FIXIT PIDIPROOF LW+ or equivalent in cement concrete / plaster work in doses by weight of cement as per manufacturer’s specification.
8
-
-
Providing & fixing SWR URPVC soil, waste & vent pipes of approved make conforming to IS:13592 (Type-B) including jointing of pipes & fittings with rubber (seal) ring & one step UPVC solvent cement ,trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work
-
-
-
110 mm nominal outside diameter pipe
64
-
-
Providing & fixing "S" or "P" trap including dismantling sorrounding concrete area and repalciing with new PVC trap with sealing of gap/joint with mixture of white cement and adhesive made of Dr. fixit i/c removal of rubbish, clay debrishes, sludge deposit and making top finish with concreting etc all complete as per direction of Engineer-in-charge. (a) For Bath , WC & Kitchen trap
3
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
-
-
-
110 mm cowl.
5
-
-
Checking and making good all leakages by applying solvent cement or m-seal / cement mortar etc. in G.I/PVC/SCI/CI pipes etc. complete as per direction of Engineer-in-Charge (New fittings to be paid for separately). The rate shall be inclusive of material costs, labour charges, tools and plants, equipments and incidentals all complete.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements