Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair And Replacement Of Perimeter Lighths, Cooling Appliances And Connected Works At Zakhama Mil Stn Under Age (i) Zakhama in Kohima, Nagaland, with an estimated contract value of Rs. 7,50,000. The bid opening date for this tender is 06-05-2025 and the last date for bid submission is 03-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 May 2025
Closing Date3 Jun 2025
Tender Amount₹ 7,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F in repairs sheet metal enclosure when MCB to be used 2 way, Single pole & neutral without bus bar complete all as specified and asdirected.

6

-

-

... More
S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.

6

-

-

... More
Supply only constant current LED driver suitable for LED luminaries of wattage of 90 Watt complete all as specified and as directed. Make: Havells/Bajaj/Philips/Crompton

22

-

-

... More
Supply only constant current LED driver suitable for LED luminaries of wattage of 60/70 Watt complete all as specified and as directed. Make: Havells/Bajaj/Philips/Crompton

20

-

-

... More
S & F in repairs cable junction box with necessary busbar and provision of incoming and outgoing cable 3 phase 4 core and fixing accesories, incl MCB SP 5 Amps ,complete all as specified and directed.

5

-

-

... More
Taking down unserviceable Air-Conditioner split Type of any capacity and make from its existing location by disconnecting electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. (Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of split type AC are deemed to be included in the unit rate of the item.

4

-

-

... More
Supply only hermetically/rotary type sealed compressor suitable for 1.5 TR split type Air conditioner. Note : Compressor oil for initial charging will be measured and paid separately

3

-

-

... More
Supply only starting capacitor, paper impregnated of capacity 80/100 mfd AC 240 volts (for 1.5 Ton AC).

3

-

-

... More
Supply only running capacitor, paper impregnated di-electric type of capacity 36-45 mfd AC 240 volt

4

-

-

... More
Supply only thermostat switch to match with the existing Air conditioner of capacity 1.5 Ton AC.

3

-

-

... More
Supply only over load protector AC 230 volt single phase for 1.5TR AC (Make : Ranutrol/Sriram).

3

-

-

... More
Supply and charging of compressor oil Make: Freezol/bajaj (Capila-D)

2

-

-

... More
Supply only PCB (electronic control circuit board) of split type AC 1.5 TR capacity of (make:- carrier/voltas)

4

-

-

... More
Taking out worn-out suction/discharge copper tube for Air-Conditioner and supply and fixing of new copper tube of appropriate quality and size to match in existing including jointing, brazing and testing complete all as specified and as directed by Engineer-in-charge suitable for split type ACs of 1.5 TR capacity.

20

-

-

... More
Dismantling of unserviceable fan motor from the Air conditioner of 1.5 Ton capacity and re-winding of fan motor with existing gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
Supply and charging of refrigerant R-22 after vaccumaziming the system thoroughly, sealing and leak testing complete all as specified and as directed by Engineeer-in-charge.

15

-

-

... More
S&F in Repair of insulation for copper tubes of Split type AC units,insulation type superion of sizen 3/8" diameter

7

-

-

... More
S&F in Repair of insulation for copper tubes of Split type AC units,insulation type superion of sizen 5/8" diameter

6

-

-

... More
S&F in repair Remote of any size and capacity of Split AC complete all as directed

2

-

-

... More
Taking down parts of Refrigerator of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item.

2

-

-

... More
Supply only hermatically sealed compressor for refrigerator of capacity upto 310 Ltrs.

2

-

-

... More
Supply only open type relay as per existing one upto 310 Ltr capacity refrigerator.

2

-

-

... More
Supply only thermostat switch to match with the existing item suitable for refrigerator of any capacity.

2

-

-

... More
Supply only PCB (electronic control circuit board) of capacity of refrigerator upto 310 Ltrs.

2

-

-

... More
Supply only over load protector suitable for refrigerator to match with the existing design.

2

-

-

... More
Taking down parts of Deep freezer of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge. Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. (b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item.

1

-

-

... More
Supply only hermatically sealed compressor for Deep freezer of capacity upto 425 Ltrs.

1

-

-

... More
Supply only open type relay as per existing one upto 310 Ltr capacity Deep freezer.

1

-

-

... More
Supply only thermostat switch to match with the existing item suitable for Deep freezer of any capacity.

1

-

-

... More
Supply only over load protector suitable for Deep freezer to match with the existing design.

1

-

-

... More
Taking down voltage stablizer and removing of burnt coil winding with new super enammeled copper winding as per existing gauge including varnishing drying alongwith replacement of unsv minor spares parts of voltage stablizer complete upto rating of 05 KVA reassembling complete all as speciied and directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.