Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMHA_830554_1Bid Award Id
ViewTender No
I.15032/NIT/Engr/2024-25/110Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special repair to existing internal Old Vintage wiring at Bn HQ Jalukie
BOQ Items
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
80
-
-
Supplying and fixing 5/6 amps piano type switch on the existing switch box/ cover including connections etc. as required.
196
-
-
Supplying and fixing 5/6 amps piano type Socket Outlet on the existing switch box/ cover including connections etc. as required.
280
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
322
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
98
-
-
Supply and fixing lamp holder case body of Bakelite with back plate suitable for batten fittings including connection etc complete all as specified and as directed.
126
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
90
-
-
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90
-
-
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
2
-
-
Supplying and fixing 8 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
24
-
-
Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2
-
-
Supply and fixing 20 amps SPN Industrial type socket outlet with plug top and metal chained cover in sheet steel enclosure.
8
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
122
-
-
Supplying and fixing 40 Amp rating, Double Pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
28
-
-
Supplying and fixing 40 Amp rating, Four Pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
8
-
-
Supplying, installing on wall, testing and commissioning of 200 A (S.C. rating for 1 sec - 25 kA) rising Mains Switch (01 No) and 100 Amp Change Over Switch (01 No) made of 1.6mm thick IP 42 sheet steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4 Nos aluminium Bus Bars having current density of 130 A/ sq cm at nominal current rating in convenient sections and suitable for 415 V, 3 phase, 4 wire, 50Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pads including jointing and earthing with 2 runs of galvanised iron strips etc. as required.
3
-
-
Supply and fixing LED tube fittings 18 watts along with pre wired of all types with all accessories and tube etc directly on ceiling/ wall including single core cable and earthing etc as required connection with 1.5 sqmm FRLS PVC insulated copper conductor.
60
-
-
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 70 Sqmm 3.5 Core.
275
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
110
-
-
Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
80
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
25
-
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
152.1
-
-
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
138
-
-
Providing and fixing of lightining conductor finial made of 25 mm dia 300mm long, copper rod, having single prong at top , with 85 mm dia 3mm thick copper base plate. Providing and fixing 25mm x 25mm copper strip in 40mm dia including holes etc complete as required.
25
-
-
Testing of Earthing to nuetral voltage of installing equipment/bldg etc by providing of elect and helper with measuring /testing equipment and tool when directed by Engineer - in - Charge. Note - Contractor should check each earth result and submit report of earthing test result in formate provided by Engineer - in - Charge and get the result sign by the Users/JE concern . Cost and testing equipment, manpower required for testing and submitting of results shall deemed to be included in the quoted rate. No extra payment shall be made on this account.
5
-
-
Material and labour for making solution of salt and water 1:5 ratio and pouring into existing earthing pit approx 15 ltr for improvement of earth continuity complete all as specified and directed by Engineer - in - Charge.
5
-
-
Supplying and fixing 40 Amp Change Over Switch MCB, SPN in the existing Panel board complete with connections, testing and commissioning etc. as required.
10
-
-
Supplying and fixing 25 Amp Change Over Switch MCB, SPN in the existing Panel board complete with connections, testing and commissioning etc. as required.
10
-
-
Supplying and fixing 32 Amp Change Over Switch MCB, SPN in the existing Panel board complete with connections, testing and commissioning etc. as required.
15
-
-
Supplying and fixing MCB Box for four Pole MCB 40 Amp, SPN in the existing Panel board complete with connections, testing and commissioning etc. as required.
10
-
-
Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specificationon on Old work (one or more coats) incl preparation of old surface by removing old paint by scrapping, sand papering incl necessary repairs to scratches etc complete on Walls.
350
-
-
SCHEDULE OF CREDIT :- Unserviceable wire 1.5 Sqmm PVC insulated aluminum conductor single core.
300
-
-
Unserviceable wire 2x2.5 Sqmm + 1x2.5 Sqmm PVC insulated aluminum conductor single core.
550
-
-
Unserviceable 5 amp Switch
196
-
-
Unserviceable 5 amp socket
280
-
-
Unserviceable wire 2x6 Sqmm + 1x 6 Sqmm PVC insulated aluminum conductor single core.
322
-
-
Unserviceable 15 amp switch
8
-
-
Unserviceable 15 amp socket
8
-
-
Unserviceable Fan regulator
90
-
-
Unserviceable Ceiling Rose
98
-
-
Unserviceable Holder various types
126
-
-
Unserviceable 20 amp Switch/socket
8
-
-