Assam Rifles Tender
View complete overview of Nagaland Assam Rifles Tender
Costs
EMD
₹ 30,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_ARMHA_510601_1Bid Award Id
ViewTender No
Engr/7Sect/2019-20/56Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://https://www.assamrifles.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for the wk Provision of Plinth for 01x PFTS shelter including site development works at COB Lungwa of AR Bn at Naginimora(Nagaland)
Cost bid for Provision of Plinth for 01x PFTS shelter including site development works at COB Lungwa of AR Bn at Naginimora(Nagaland)
BOQ Items
Constr of Septic tank 50 users as per Drg No IGAR(N)/ENGR/2016/16 SHT 1/1.
1
-
-
Making soak pit 2.50 m diameter 3.00 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
1
-
1
Constructing brick masonry manhole with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in cement mortar 1:4 with R.C.C. top slab with 1:2:4 mix using stone aggregate 20 mm nominal size, foundation concrete 1:4:8 mix using stone aggregate 40 mm nominal size, inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 using stone aggregate 20 mm nominal size finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg).
4
-
-
Providing and laying and jointing 100 mm dia glazed stone ware pipe including cement concrete bed and haunching with PCC 1:4:8
6
-
-
RETAINING WALL
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m and getting out hard/dense soil.
63.45
-
-
M/L for PCC 1:4:8, type D2 for foundation filling and mass concrete.
21.15
-
-
M/L for random rubble masonry with hard stone in retaining wall, including leveling up with cement concrete 1:6:12 in CM 1:6.
109.26
-
-
M/L for PCC 1:2:4 type B 1 as in coping.
1.76
-
-
M/L for raised pointing to random rubble masonry surfaces using CM 1:4.
75
-
-
M/L for loose filling agg of gauge 63mm to 45mm on back side of retaining wall.
0.15
-
-
M/L for PCC 1:3:6 for weep hole.
0.45
-
-
M/L for 110 mm dia PVC pipe for weep hole.
83.7
-
-
M/L for PCC 1:3:6 for drain wk.
8.1
-
-
M/L for fininshing over PCC drain with CM 1:3 6 mm thick inclding form wk for drain wk.
36
-
-
EARTH CUTTING
-
-
-
Earth work in excavation over areas by mechanical means (Hydraulic excavator)/ manual means in including getting out the excavated soil and disposal of surplus excavated soil , within a lead of 50m m lead and lift upto 1.5 m as directed
292.5
-
-
INTERNAL ELECTRIFICATION
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group A
13
-
-
Wiring forone 3 Pin 5 Amps socket outlet with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required
16
-
-
Wiring forone 3 Pin 15 Amps socket outlet with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required
16
-
-
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 5/6 amps switch
17
-
-
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 3 pin 5/6 amp socket outlet
4
-
-
Supplying and fixing following piano type switch/ s ocket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 amp Switchsocket combined co outlet
4
-
-
S/F of switch fuse iron clad or sheet metal TP fused and neutral link 63 mm Amps 415 Volts
1
-
-
S/F of distribution board iron clad or of sheet metal SP fuse neutral link 32 Amps 415 V 4 Way
1
-
-
S/F of bulk head light fitting complete as specified with glass cover
2
-
-
S/F of flouroscent tube light box typre fitting complete 1x36 Watt electronic choke
4
-
-
S/F PVC rectangular block 25 Cm x 20Cm x5 Cm depth
4
-
-
S/F PVC rectangular block 20 Cm x 15Cm x5 Cm depth
4
-
-
S/F of ceiling rose surface backalight 65x50 mm two to three terminals
6
-
-
M/L for brick masonry earthing chamber including earth work in excavation and PCC 1:2 :4 incl 25x5 mm GI strip 5.7 mtr long as earthing lead etr complete
1
-
-
S/F brass battan holder including connection etc as reqrd
4
-
-
SUPPLY OF BUILDING MATERIALS
-
-
-
Paint Synthetic enamal white in 04 Ltrs pkt
20
-
-
Paint synthetic enamel Smoke Grey in 04ltrs pkt
16
-
-
Redoxide/Steel primer in 20 ltrs pkt
20
-
-
Thinner/Paint Reducer
18
-
-
Painting Brush 100 mm size
4
-
-
M S Foundation bolts and nuts 18mm dia 300mm long
49.2
-
-
M S nut &bolts 12mm dia ,60mm long
32.94
-
-
M S nut &bolts 6mm dia ,100mm long
3.84
-
-
M S nut &bolts 10mm dia ,75mm long
11.61
-
-
M S J/L hooks& limpet washers
25
-
-
MS full threaded screws various sizes
10
-
-
MS Rivers/Repeats various sizes
6
-
-
LN key 10mm
2
-
-
Welding Rod
10
-
-
Rivet machine
1
-
-
Solvent cement(Gum)
12
-
-
Replacement/Repair of damage s parts of PUF shalter (Ceiling Panel-04,window panel-04,Door panel-03,Wall panel lock-14,Base purline -15 base plate -05 etc
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements