Public Works Department Tender

View complete overview of Mizoram PWD Tender

Public Works Department - PWD Tender

Works
Eprocure

Opening Date

20 Mar 2019

Closing Date

22 Apr 2019

Tender Amount

₹ 6,38,86,705 
Notes
Download

Costs

Summary

Construction Of Pangzawl To Lungmawi Upto R.mat Road

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Groove Conrete Road with provision of edge stone. Construction of Groove concrete pavement, thickness as per design, over a prepared sub base, with concrete strength M30(Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of admixtures as approved, curing of concrete slabs for 14-days, including cutting of groove at 1 metre interval in both direction using concrete joint cutting machine.

2474.821

-

-

... More
Construction of earthen shoulder. Construction of subgrade and earthen shoulder with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compavted to meet requirement of table 300.2 with lead upto 1000m as per technical specification clause 303.1.

4355.685

-

-

... More
Earthwork in excavation for structures as per drawing and technical Specification Clause 305.1. including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and back filling in trenches with excavated suitable material.I. Ordinary soil (upto 3m depth)

200.84

-

-

... More
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802, 803, 1202 & 1203. I. PCC Grade M10. Nominal Mix 1 : 3 : 6 (hand mixing).

6.38

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204. II. Course rubble masonry (2nd sort). (iii) in cement mortar 1 : 5.

100.04

-

-

... More
Providing and laying filter media with granular crush aggregates as per specification to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind retaining wall to the full height compacted to firm condition complete as per drawing and technical specification clause 1204.3.8

54

-

-

... More
Stone masonry in cement mortar 1:3 for parapet complete as per drawing and technical specifications Clauses 700 and 1208.4. I. Random rubble masonry.

3.175

-

-

... More
Plastering with cement mortar ( 1:4) 15mm thick on Brick/Stone works as per drawing and technical specification clauses 613.4 and 1204

31.325

-

-

... More
Providing PCC M20 architectural coping on the top of retaining wall complete as per drawing and technical specification clause 615,710 and 1204.3.11.

6.25

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications clauses 702, 704, 1202 & 1203. II. Coursed rubble masonry. (ii) In 1 : 4 cement mortar.

113.85

-

-

... More
Providing and laying parapet with pcc M15 as per drawing and technical specification clause 800 and 1208.4. (i) Nominal mix 1:2.5:5(Hand Mixing)

49.8

-

-

... More
Plastering with cement mortar (1:3) 15mm thick works as per drawing and technical specification clauses 613.4 and 1204

258.96

-

-

... More
Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC : 8 fixing in position including painting and printing, etc. as per drawing and Technical specification clause 1703. i) 5th kilometre stone (precast)

2

-

-

... More
Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC : 8 fixing in position including painting and printing, etc. as per drawing and Technical specification clause 1703. ii) Ordinary kilometre stone (precast)

6

-

-

... More
Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC : 8 fixing in position including painting and printing, etc. as per drawing and Technical specification clause 1703. iii) 200m stone (precast)

37

-

-

... More
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801. (ii) 60cm equilateral Triangle Speed limit

2

-

-

... More
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801. (ii) 60cm equilateral Triangle Left Hand Curve

11

-

-

... More
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801. (ii) 60cm equilateral Triangle Right Hand Curve

11

-

-

... More
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801. (ii) 60cm equilateral Triangle Men at Work

1

-

-

... More
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801. (ii) 60cm equilateral Triangle School

2

-

-

... More
Providing and fixing of retro-reflectorised cautionery, mandatory and informatory sign as per IRC : 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over alluminium sheeting 1.5mm thick supported on mild steel angle iron post 75x75x6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mmx 450mmx 600mm, 600mm below ground level as per drawing and Technical specification clause 801. (ii) 60cm equilateral Triangle Falling Rocks

2

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Destination Sign

1.62

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Place Identification Sign

0.75

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Advance Direction Sign

1.62

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Direction Sign

0.36

-

-

... More
Providing and fixing as per Guidelines: PMGSY Logo

6

-

-

... More
Providing and fixing as per Guidelines: Title Informatory Board

2

-

-

... More
Providing and fixing as per Guidelines: Citizen Informatory Board

1

-

-

... More
AMC for 1st Year

7.1

-

-

... More
AMC for 2nd Year

7.1

-

-

... More
AMC for 3rd Year

7.1

-

-

... More
AMC for 4th Year

7.1

-

-

... More
AMC for 5th Year

7.1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.