Military Engineer Services Tender

View complete overview of Mizoram MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date1 Feb 2025
Closing Date27 Feb 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed

4.67

-

-

... More
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed

25

-

-

... More
B/R WORKS

-

-

-

... More
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed

3

-

-

... More
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed

270

-

-

... More
Demolition of reed, lathing, single or double including battens and plaster or chiken wire lathing complete all as specified and as directed

285

-

-

... More
Dismantling asbestos cement (corrugated/semi corrugated) in roof coverings, etc including ridges, claddings, etc. and disposing off including all necessary staging / scaffolding, etc. as required complete all as specified and as directed

235

-

-

... More
Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed

5.45

-

-

... More
Dismantling wall and ceiling boards (fibre, pulb, insulation, etc.) or insulation boards slabs/blankets of any thickness including cover fillets complete all as specified and as directed

160

-

-

... More
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed

14.5

-

-

... More
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces

15

-

-

... More
Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4.0sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces

19

-

-

... More
S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed

1600

-

-

... More
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed

545

-

-

... More
S&F screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 11 to 15mm complete all as specified and as directed

30

-

-

... More
S&F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachment of Fe 410W grade-E -250, quality 'B' complete all as specified and as directed

50

-

-

... More
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed

920

-

-

... More
M&L for mild steel TMT bars grade Fe-500D, 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed

580

-

-

... More
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders securing with clips complete all as specified and as directed

570

-

-

... More
M&L for use and waste formwork to sides of concrete foundations, bases of columns, rafts, raft beams, plinth beams and similar works, vertical or to batter, for rough finished flat surfaces of concrete complete all as specified and as directed

63.2

-

-

... More
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed

64.8

-

-

... More
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 100mm but not exceeding 200mm wide complete all as specified and as directed

458

-

-

... More
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed

4.7

-

-

... More
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed

235

-

-

... More
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles, mass concrete, etc. complete all as specified and as directed

6.2

-

-

... More
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in columns, posts, piers, pillars, struts, etc. complete all as specified and as directed

3.15

-

-

... More
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed

5.6

-

-

... More
M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed

40

-

-

... More
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in bed blocks, back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed

0.15

-

-

... More
M&L for preparation of masonry / concrete wall surfaces and applying 1mm thick wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed

340

-

-

... More
M&L for preparation of masonry / concrete wall surfaces and applying 1mm thick weather proof wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed

270

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein

270

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:6) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed

340

-

-

... More
Supply only integral water proofing compound all as specified

20

-

-

... More
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed

23.5

-

-

... More
S&F factory fabricated solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with but 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed

15.08

-

-

... More
S&F factory made solid PVC panelled door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed

11.34

-

-

... More
S&F factory made solid PVC wire gauged door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed

6.1

-

-

... More
S&F 3 way sliding anodised aluminium glazed window shutter with frame with the following specifications complete all as specified and as directed. (a) Frame 50x65x1.5mm thick (b) 35x35x1.5mm Z section in stiles, rails (c) 50x35x1.5mm T section mullion (d) PVC gasket and with 4.8mm thick coloured glass pane one side mirror finished, area not exceeding 0.5sqm each with aluminium handles and necessary locking arangements (e) Stainless steel wire mesh for mosquito proofing arrangement all as directed

20

-

-

... More
S&F 2 way sliding anodized aluminium glazed ventilator shutter with frame consists of following specification complete all as specified and as directed (a) Ventilator frame 2 track of size 60x25x1.5mm thick (b) Stiles and rails of size 35x25x1.5mm (c) 35x35x1.5mm T section mullion (d) PVC gasket with 4mm thick tinted glass, including aluminium handles with necessary locking arrangement

1.6

-

-

... More
Notes for item Nos. 42 & 43: (a) Area of opening shall only be considered for meaurement purposes (b) All necessary accessories including tinted glass, PLPB, fittings, fixtures for assembling / fixing as per drawing complete shall be included in the quoted rate

-

-

-

... More
S&F 100mm long stainless steel butt hinges of selected quality complete all as specified and as directed

57

-

-

... More
S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed

38

-

-

... More
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed

38

-

-

... More
S&F in repairs 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed

8

-

-

... More
S&F 140mm floor door stopper aluminium alloy body and tongue, anodized with hard drawn steel spring fixed on floor complete all as specified and as directed

8

-

-

... More
M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound 'A' complete all as specified and as directed

2.8

-

-

... More
S&F in repairs 20mm dia fancy type chromium coated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of CP MS brackets, holders with funnel at ends complete all as specified and as directed

37

-

-

... More
S&F false ceiling with fully perforated 12mm thick micro tegular edge of 10mm thick square at all heights with glass reinforced gypsum ceiling tiles of size 595x595mm, if approved texture, pattern and design having moisture content less than 2%, humidity resistance 99%, NCR (0.75 to 1) as per IS-8225:1987 (updated till date), nn-combustible as per BS: 475 (Part-IV) 1970 (updated till date), reflectance minimum 85% when laid truely horizontal level, suspended from interlocking 'T' grid of hot dipped galvanized (galvanized @120gm/sqm) iron section 0.33mm thick, network comprising of main T runner of size 32x15mm 3000mm long, cross T of size 32x15mm 1200mm long, secondary intermediate cross T of size 32x15mm 600mm long, forming grid size of 600x600mm duly suspended from soffits of slab with galvanized (galvanized @80gm/sqm) iron wire 8mm outer dia, 50mm long, alongwith 6mm dia fully threaded hanger rods upto 1000mm length, L shaped adjusters of size 85x25mm GI perimeter angle of size 24x24x0.4mm 3000mm long, fixed with anchor fastners @450mm c/c and 40mm long dry wall screws complete all as per drawings, as specified and as directed

150

-

-

... More
M&L for preparation of new masonry / concrete wall surfaces and applying two coats of acrylic distemper (tint as approved) over and including one coat of alkali resistant walll primer with all necessary staging, scaffolding, etc. as required complete all as specified and as directed

340

-

-

... More
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed

82

-

-

... More
M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed

270

-

-

... More
M&L for vitrified tiles, light shade, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed

180

-

-

... More
M&L for glazed ceramic tiles, coloured, of sie 450x300x7mm or 350x250x7mm thick of superior quality as in skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

85

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed

220

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed

15

-

-

... More
E/M WORKS

-

-

-

... More
Supply, installation & commisioning of multicavity, power free, automatic, erosion feed enabled, controlled release water sanitizer/conditioning treatment station with proportional dosing arrangement consisting of Station Base Assembly (80-100L) with water inlet irrgeulator, overflow vent, water outlet regulator with non return valve ( for standalone gravity flow) water outlet regulator ( for offline automatic gravity), drain valve, fluid level controller, sludge level gauge and station base buffer, station hood Assembly with multicavity arrangement (11-13) with lids, processor,1/2 inch processor outlet & processor inlet connection and flexible connecting duct,material of inlet connections and flexible thermoplastics/FRP maximum temperature 45 degree, compatibility stequa 411 AE refils with all accessories, complete all as specified and as directed.

2

-

-

... More
Supply and install plastic cylinder sealed disposable sanitiser refill containing solid chlorine for disinfection of drinking water arrangement for controlled release of disinfection in water, suitable for operation through recommendation dosing system replacement indication visual & weight variation water contact orifice design sealed when dry, exposed upon immersion operation type non contact inhalatory cylinder height minimum 10 inches +-5 inches, complete all as specified and as directed.

2

-

-

... More
Supply, installation and testing Monoblock Electric Pump, 1500 RPM,1 HP 220V , 50 Hz, complete all as specified and as directed.

3

-

-

... More
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed

76

-

-

... More
Taking down old unserviceable MCB DBs, enclosures, junction boxes, metal plug sockets, etc. from any location or position and disposing off complete all as specified and as directed

4

-

-

... More
M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:

-

-

-

... More
One light point controlled by one 5A one way switch

27

-

-

... More
One ceiling fan / exhaust fan point controlled by one 5A one way switch

15

-

-

... More
One call bell point controlled by one 5A one way switch

3

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on independent board

15

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on same board

12

-

-

... More
M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed

4

-

-

... More
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed

10

-

-

... More
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 230V complete all as specified and as directed

7

-

-

... More
S&F switch socket combination outlet, 2 in 1, 5 & 15A flush type, ISI marked, 230V complete all as specified and as directed

2

-

-

... More
S&F switch socket combination outlet, 5 in 1, 6 pin, 5 & 15A flush type, ISI marked, 240V complete all as specified and as directed

4

-

-

... More
S&F switch socket outlet, 5 pin, 5A flush type, universal, ISI marked, 230V complete all as specified and as directed

3

-

-

... More
S&F bell push flush type, single pole, ISI marked, one way 5A, AC 230V complete all as specified and as directed

3

-

-

... More
S&F bell buzzer, ding dong type, 230V, single pole, 50Hz, AC complete all as specified and as directed

3

-

-

... More
S&F switch piano flush modular type, single pole, ISI marked, one way 6A, 1 module, 230V complete all as specified and as directed

43

-

-

... More
S&F switch piano flush modular type, single pole, ISI marked, one way 16A, 1 module, 230V complete all as specified and as directed

9

-

-

... More
S&F socket outlet, 2/3 pin, 6A modular type, ISI marked, combined 2 module, 230V complete all as specified and as directed

9

-

-

... More
S&F socket outlet, 2/3 pin, 6/16A modular type, ISI marked, combined 2 module, 230V complete all as specified and as directed

9

-

-

... More
S&F in repairs modular white cover plate with frame ISI marked complete all as specified and as directed suitable of the following modules:

-

-

-

... More
4 module

9

-

-

... More
8 module

9

-

-

... More
10 module

9

-

-

... More
S&F electronic fan regulator, modular type, stepped type (5 steps), 100W, 230V, 2 module, ISI marked duly connected up complete all as specified and as directed

13

-

-

... More
S&F recessed surface mounting LED light fitting, 1x36W, IP-54, white powder coated CRCA housing, 2'x2', 230V AC with high power LED lamp with all accessories pre-wired internally and connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable fitting and disposing off complete all as specified and as directed

6

-

-

... More
S&F in repairs fan hook fabricated in MS flat iron 25x6mm 300mm long, bent to shape with drilled holes to accommodate nuts suitable for hanging ceiling fans, entirely painted with two coats of synthetic enamel paint complete all as specified and as directed

9

-

-

... More
S&F LED decorative light fitting, 7.5W, indoor type, sleek classic wall light, antique finish, suitable for living / bed room lighting, of approved design with 7.5W LED lamp, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old fitting complete all as specified and as directed

2

-

-

... More
S&F wall surface mounted, compact LED box type, 4ft long, light fitting 1x20W all accessories prewired with 20W LED lamp and connecting with three core flexible copper conductor cable of suitable size from ceiling rose including taking down and disposing off old fitting complete all as specified and as directed

10

-

-

... More
S&F recess mounting down light 6Watt LED light fitting, pressure die cast alminium housing powder coated white, with drop down PC diffuser, optimized heat sink, efficient heat dissipation, replaceable electronic driver and all connecting accessories and connecting up complete all as specified and as directed

2

-

-

... More
S&F building security light, LED luminaire 25W IP 66 with LED lamp, driver, etc. with all accessories pre-wired and connecting with 3 core flexible copper conductor cable drawn through PVC conduit of size 20mm and taking down and disposing off old fitting complete all as specified and as directed

4

-

-

... More
S&F bulk head fitting LED, 10W, with pressure die cast housing, acrylic diffuser with frame and connecting accessories and connecting up including taking down old fitting and disposing off complete all as specified and as directed

3

-

-

... More
M&L for taking down unserviceable ceiling fans / wall mounted fans of any type from existing location and depositing at AGE E/M store including all loading, unloading, carting, etc. as required complete all as specified and as directed

16

-

-

... More
S&F ceiling fan 1200mm sweep, of colour & design as approved, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories complete all as specified and as directed

9

-

-

... More
Fixing only exhaust fan 230V AC single phase complete with louvers and shutters 250mm sweep and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts and taking down old / unserviceable fan from any location / position and disposing off complete all as specified and as directed Note: Exhaust fans shall be issued under Sch-'B' free for fixing only

6

-

-

... More
S&F metal clad socket outlet with single pole enclosure with 5 pin and earth plug socket including 1No. MCB SP 32A 10kA 240V and taking down and disposing off old/unserviceable socket complete all as specified and as directed

6

-

-

... More
S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed

2

-

-

... More
S&F sheet metal enclosures for 4 way MCB DB, 415V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed

2

-

-

... More
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed

70

-

-

... More
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 2.5sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site

10

-

-

... More
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site

40

-

-

... More
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site

30

-

-

... More
S&F single core PVC insulated and PVC sheathed cable FRLSH with stranded copper conductor of size 1.5sqmm, 1100V grade complete all as specified and as directed

10

-

-

... More
S&F in repairs MCB SP, 240V, 10 to 40A, 10kA, 50Hz, C curve complete all as specified and as directed

12

-

-

... More
S&F in repairs MCB isolator SPN, 240V, 40A, 10kA, 50Hz, C curve complete all as specified and as directed

2

-

-

... More
S&F in repairs MCB isolator TPN, 240V, 63A, 10kA, 50Hz, B curve complete all as specified and as directed

3

-

-

... More
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes

2.84

-

-

... More
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed

280

-

-

... More
S&Fsteel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. complete all as specified and as directed

6

-

-

... More
Supply, laying, jointing, connecting and testing 2 core 16sqmm XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, conforming to IS: 7098 (Part-I), heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective item herein

35

-

-

... More
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed

2

-

-

... More
Notes for serial item No.114: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.