Urban Affairs Department Tender

View complete overview of Meghalaya Urban Affairs Department Tender

Urban Affairs Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date15 Mar 2024
Closing Date30 May 2024
Tender Amount₹ 2,15,00,00,000 
Notes
Download

Costs

Summary

Construction Of Unity Mall And Infrastructure In The New Shillong Township

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. C) ln hard rock (ii) BIasting prohibited

117.03

121944

1042.03

... More
Earthwork in excavation by Mechanical means up to a depth of 2-4m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

442

287627

650.74

... More
Earthwork in excavation by Mechanical means up to a depth of 4-6m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

442

375042

848.51

... More
Earthwork in excavation by Mechanical means up to a depth of 6-8 m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

221

231229

1046.29

... More
Earth work in excavation by manual/ mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge. B) ln ordinary rock

49596.3

19353964

390.23

... More
Earth work in excavation by manual/ mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge. C) ln hard rock (ii) Required BIasting

2755.35

2109440

765.58

... More
Earth work in excavation by manual/ mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge. C) ln hard rock (ii) BIasting prohibited

2755.35

2751051

998.44

... More
Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m. (a) With available excavated earth

2833.95

424879

149.93

... More
Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 in . B) With borrowed earth/ stone dust carriage up to 5 Km

174462.36

54538679

312.61

... More
Providing and laying good quality cinder (steam coal) concrete in cement cinder mix (1:15) proportion using 12.5 mm nominal size cinder laid in layers and compacted as directed for filling sunken floors including cost and conveyance of all materials, water to work site, seigniorage charges and all operational, incidental, labour charges, such as mixing cement & cinder etc. complete for finished item of work as directed by Engineer In-charge.

129.6

744422

5744

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Tables 300.2 with all lead and lift as per Technical Specification Clause 303.1.

1844.08

1229427

666.69

... More
Lime Treated Soil for Sub-Base Subgrade Providing, laying and spreading soil on a prepared sub-grade, pulverizing, mixing the spread soil in place with rotavator with 4 percent slaked lime with minimum content of 70 percent of CaO, grading with motor grader and compacting with the road roller at OMC to achieve at least 98 per cent of the maximum dry density to form a layer of sub-base as per Technical Specification Clause 403.

1844.08

4339267

2353.08

... More
Granular sub-base/ base/ surface course with local materials (Table 400.13) by mix in place method normal construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheeled roller to achieve the desired density complete as per Technical Specification Clause 408. (i) Using Naturally Occurring Gravel

1933.85

4188606

2165.94

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/ base course on a well prepared sub-base and compacting with smooth wheel roller of 80-100 kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc. as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means

2305.1

11951139

5184.65

... More
Providing soling with stone, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. B) Stone Soiling (ii)150mm thick

12060.51

7732837

641.17

... More
Prime Coat (i) low Porosity: Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means as per Technical Specification clause 502.

4817.64

297108

61.67

... More
Tack Coat with Bitumen Emulsion (ii) Providing and applying tack coat with bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg/sqm on the dry and hungry bituminous surface cleaned with hydraulic broom as per Technical Specification clause 503.

9635.27

204903

21.27

... More
Dense Graded Bituminous Macadam: Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP/ DMP 60-90 TPH capacity/ 80-100TPH capacity using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specification clause no. 507 complete in all respects. 40mm Nominal size Grading

674.48

6642953

9849

... More
Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant/ DMP 60-90 TPH capacity/ 80-100 TPH capacity using crushed aggregates of specified grading, premixed with bituminous binder @5.0 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specification clause no. 507 complete in all respects. 19mm Nominal size Grading

251.25

2538881

10105

... More
Filling sunken floor with broken brick bats/ stone aggregates and sand including compacting and supplying of materials complete as specified and directed for all levels.a) Brick Bats

10

41096

4109.66

... More
Disposal Of surplus earth/ unserviceable material from the work site including loading and unloading complete with all lead & lift as directed by Engineer Incharge.

20741.93

3374296

162.68

... More
PCC: Providing & laying Plain Cement Concrete works in foundation bed for footing steps, walls, brick works etc. below plinth level as directed and specified including dewatering if necessary, and curing complete as directed by Engineer Incharge. B) M10 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)

4062.72

32835504

8082.14

... More
Providing and laying in position mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying including the cost of centering, shuttering, finishing and admixtures in recommended proportions as per lS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer In-charge. A) All works upto plinth level

7964.42

94059788

11810

... More
Providing and laying in position mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying including the cost of centering, shuttering, finishing and admixtures in recommended proportions as per lS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer In-charge. B) All works above plinth level up to first floor level

8207.62

101897602

12415

... More
Providing and laying in position mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying including the cost of centering, shuttering, finishing and admixtures in recommended proportions as per lS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer In-charge. C) All works above first floor level up to second floor level

873.33

11456342

13118

... More
Providing and laying in position mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying including the cost of centering, shuttering, finishing and admixtures in recommended proportions as per lS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer In-charge. D) All works above Second floor level up to Third floor level

465.85

6438512

13821

... More
Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to all levels/ floors, including the cost of cantering, shuttering, finishing, but excluding reinforcement. M20 1 :1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)

719.05

8054738

11201.87

... More
Providing and laying in position mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying including the cost of centering, shuttering, finishing and admixtures in recommended proportions as per lS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer In-charge. For Deck Slab, Bridge Slab and other all required elements

399.55

4963247

12422

... More
Supplying, fitting and fixing in position Thermo-Mechanically Treated (TMT) reinforcement bars conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) A) All works foundation, below plinth level and up to 1st floor level

1790785.81

209951728

117.24

... More
Supplying, fitting and fixing in position Thermo-Mechanically Treated (TMT) reinforcement bars conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) B) All works above first floor level up to second floor level

151944.73

18038878

118.72

... More
Supplying, fitting and fixing in position Thermo-Mechanically Treated (TMT) reinforcement bars conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) B) All works above Second floor level up to Third floor level

81177.44

9757528

120.2

... More
Trimix: Providing and laying C.C. Pavement of mix M-30 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. including panel shuttering, centring, groove cutting and filling sealant complete as per specifications and directions of Engineer In-charge.

2153.08

28416310

13198

... More
Covering top of membrane with Geotextile, 250 gsm non-woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufacturer's recommendation.

18632.02

1882020

101.01

... More
Supplying and laying and placing of 330mm weld spacing FC Flexicell/ Geocell of 250mm cell depth for stabilizing the sub-grade of road work in all respect including all except cost of filler material as per direction of Engineer Incharge .

6847.49

5019210

733

... More
Supplying & laying of bi-axial extruded high modulus polypropylene Geogrid coforming to Morth specification for base/ sub-base reinforcement having minimum tensile strength 40kN/m in the longitudinal and transverse direction, with 14kN/m and 28kN/m tensile strength at 2% and 5% strain respectively in the longitudinal and transverse direction, junction efficiency not less than 95% and with 38mm x 38mm mesh opening.

5958.5

3307265

555.05

... More
Providing weep holes in brick/ stone masonry, plain/ reinforced concrete abutments, wing walls, return walls with 100 mm dia AC pipe extending through the full width of the structures with slope of 1 (V) : 20 (H) towards drawing face complete as per drawing and Technical Specification Clauses 614, 709, 1204.3.7.

1634

1030297

630.54

... More
Supply & loading, of relevant activity wise specifications referring to CPWD manuals etc. completed for Internal dimension 300mm X 300mm Precast 2000mm long U-shaped drain and 500mm long 60mm thick Precast Lid Perforated Cover for various size and types of storm water drain as specified in detail drawings confirming to Japanese Industrial Standards, ASTM & satisfying relevant IS code requirements, manufactured by using advanced precast technology having High Performance Self Compacting Concrete of M-40-cylinder strength or M-50 Cube strength, steam cured and using Fe 500D reinforcement bar. It shall have tie shape groove of 10-20 mm width x 2 mm depth as per manufacturing specs on both sides of each precast unit product for jointing two precast units & designed to take T-6 load as side drain– 4.8 T, axle load – 2.4 T, wheel load confirming the precast manufacturer should have minimum 5 years of work experience in production of similar precast products in India. It shall have proper provisions at appropriate location for mechanical installation, including supply, transportation, loading, at project site. Manufacturer shall produce product guarantee for minimum 10 years. Precast products shall be of Fuji or Equivalent as approved by authority. No casting shall be allowed to be prepared at site in any case. It should be casted in the stringent atmospheric & pre-defined condition, as per approved QAP by Engineer In-charge.

712.5

3239958

4547.31

... More
Providing and fixing 20mm thick drain cells with surface area consisting 90-95% void and made of 100% recycled polypropylene. It shall be unaffected by moulds, algae, soil-borne chemicals, bacteria and bitumen and shall serve at the temperature ranging from 30 to 120 degree Celcius. It shall possess the compessive strength of 163.4 tonne/sqm and the flow rate per unit width shall be greater than 320 litre/min. The rate shall include all the material, fixing, labour and machinery all complete as per drawing and as directed by Engineer In-charge.

1257.94

957292

761

... More
Sand filling in plinth in layers not exceeding 150 mm thick including breaking of clods, consolidating by ramming and watering complete as directed by Engineer In-charge.

1632.05

3278076

2008.57

... More
Supplying, filling, spreading & levelling gravels of size range 5 to 10 mm for lake/ pond, swale, pathway etc. complete, in the required thickness, for all leads & lifts, all complete as per direction of Engineer In-charge.

50

127330

2546.6

... More
Supplying, filling, spreading & levelling stones boulders of size range 100 to 300 mm for lake/ pond, swale, etc. complete, in the required thickness, for all leads & lifts, all complete as per direction of Engineer In-charge.

1637.17

3004626

1835.26

... More
Supplying, filling, spreading & levelling stones boulders of size range 300 to 2000 mm including making shape, cutting, chiselling, grouting and fixing with required holefast for lake/ pond fall, swale fall, etc. complete, in the required thickness, for all leads & lifts, all complete as per direction of Engineer In-charge.

800

2430448

3038.06

... More
PVC Sleeve 50mm - Providing, placing and fixing PVC sleeve 50mm dia in slab, beam, walls, etc. as per the details shown in drawing.

501.31

80710

161

... More
PVC Sleeve 75mm - Providing, placing and fixing PVC sleeve 75mm dia in slab, beam, walls, etc. as per the details shown in drawing.

441.25

74570

169

... More
PVC Sleeve 110mm - Providing, placing and fixing PVC sleeve 110mm dia in slab, beam, walls, etc. as per the details shown in drawing.

441.25

115164

261

... More
PVC Sleeve 160mm - Providing, placing and fixing PVC sleeve 160mm dia in slab, beam, walls, etc. as per the details shown in drawing.

441.25

319461

724

... More
Grinding, Chamfering and moulding of concrete in reinforced concrete work at all levels and according to shapes, disposal of waste materials for all lead and lift including equipment, safety precautions etc. complete as per specification, drawing and directed by Engineer In-charge, but excluding cutting of reinforcement.

787.96

376644

478

... More
Core Cutting : Providing and wet drilling accurate and clean holes of specified diameter in walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine including scafolding, safety majors, disposing the debris, cleaning for all levels/ all height as per drawing etc. compete. Rate shall be inclusive of filling the hole with non shrink grout and waterproof in good manner. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency only. (a) holes from 1mm to 150 mm dia.

393.98

1702387

4321

... More
Core Cutting : Providing and wet drilling accurate and clean holes of specified diameter in walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine including scafolding, safety majors, disposing the debris, cleaning for all levels/ all height as per drawing etc. compete. Rate shall be inclusive of filling the hole with non shrink grout and waterproof in good manner. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency only. (b) holes from 150mm to 300 mm dia.

393.98

2127492

5400

... More
Structural Steel Work : Providing, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes/ all sizes with all leads and lifts using Hot dip Galvanized (Zinc) thickness of min. 140 (µm) micron after grit/ sand blasting over E300 grade of MS Rolled Steel Sections, Hollow Sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheets, Flats, Bright Bars, Angles, MS Sheet, Girder, Channels, Beams, Threaded GI bolts, Threaded J bolts, Insert Plates, Support Plates etc. all confirming to latest relevant IS Codes for Structural Steel Work such as gratings over drain channels, staircases, railings, handrails, jali, gates, grills, bracings, platforms, brackets, ladders, monkey ladders, cattle traps, windows, pipe racks, rugs, false ceiling frames, roofing, canopy, fencing posts, screen/ fencing frames etc. including wastage, straightening, cutting, shapes, bending, curving, carving, bolting and welding the members at site/ shop as per structural drawings and detailed specifications for materials & workmanship including necessary scaffolding/ staging etc. complete in the situations described hereinafter and comprising of: i) Profile cutting of components to required length/ width and shape/ profile; ii) Smooth grinding/ machining of edges/ faces/ all welding joints; iii) Necessary welding (electric arc welding) for required weld lengths and sizes. iv) Machine drilling of holes for joining/ anchoring (measurement will be paid for as actual cut length used at site). The rate shall include grit/ sand blasting, degreasing and preparation of rust free surface manually or mechanically, Hot dip Galvanized (Zinc), applying chemical pre-treatment to the prepared surface to improve adhesion of subsequent coat, 2 coat of Epoxy Paint thickness of min. 150 (µm) micron and 1 coat of PU Paint thickness of min. 60 (µm) micron of approved shade of paint by spray only till required finish/ shade over all the surfaces of the steel sections after proper surface preparation.

225918.3

49927944

221

... More
*Note: The contractor shall submit fabrication/ shop drawings based on construction drawings and approved 2 9two) mock up from Architect. The fabrication work shall start only after approval of the fabrication drawings submitted by contractor. Any change required for stability in the fabrication drawings shall be carried out at no extra cost. Fabrication shall be executed in a perfect architectural workmanship and as per section V & VI of IS 800 & IS 7215. Welding shall be carried out by qualified welders/ fabricators of required length, grinding, finishing edges, filling and finishing the welded spots/ gaps with grout/ sealant/ chemical. The nut-bolts, washers, anchor fasteners, rivets, nails, screws and other accessories etc. must be hot dip galvanized/ zinc coated for safety and structural stability of all works at site. The rate for the completed structural steel work shall be included the cost of all materials, labour, tools, plant and equipment required for fabrication, connections, oiling, painting, temporary erection, inspection, tests and complete final erection inclusive of breaking the floor/ slab/ beam for anchoring/ bolting and it's repair for the work as shown in the drawings, specifications and as directed by the Engineer In-charge. a) Yield Strength of 250 Grade

-

-

-

... More
b) Yield Strength of 310 Grade

266486.46

62890804

236

... More
c) Yield Strength of 350 Grade

491519.8

123371469

251

... More
Random Rubble Masonry with hard stone in foundation, plinth and superstructure including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to all levels/ floors and visible outer finish of stone as per drawing with: (a) Cement mortar 1:6 (1 cement: 6 coarse sand)

6652.23

43133059

6484

... More
Random Rubble Masonry Cladding with hard stone (cherra/ local stone block) in foundation, plinth and superstructure up to all levels/ floors and visible outer finish of stone as per drawing with: (a) Cement mortar 1:6 (1 cement: 6 coarse sand)

355.07

2044787

5758.83

... More
Cladding- Providing, supplying, fitting, fixing and laying of dressed stone block walling and tile slab (cherra/ local stone block) laid on 25mm thick base in cement mortar 1 :3, jointed with grey cement slurry, pointing with white cement slurry of required colour pigment including clearing, rubbing etc. complete as a cherra stone block (300mm x 150mm x 50mm)

121.34

360612

2971.92

... More
Pointing on Stone work or Stone flooring with cement mortar 1:3 (1 cement : 3 fine sand): Flushed/ Pluled/ Strucked or Weathered Pointing

4893.27

853293

174.38

... More
Pointing on Brick work or Brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): Flushed/ Pluled/ Strucked or Weathered Pointing

373.5

65131

174.38

... More
Dry brick on flooring/ lining in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with local sand, with common burnt clay non modular bricks. (For Lake/ Pond/ Pathways)

4971.24

3937470

792.05

... More
Providing and laying Block Masonry with 100mm thick (Autoclaved Aerated Cement) AAC blocks in super structure in cement mortar 1:4 (1 cement: 4 coarse sand). The rate includes providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of masonry work. A) All works foundation, below plinth level and up to 1st floor level

31.6

245444

7768.47

... More
Providing and laying Block Masonry with 100mm thick (Autoclaved Aerated Cement) AAC blocks in super structure in cement mortar 1:4 (1 cement: 4 coarse sand). The rate includes providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of masonry work. (B) All works above first floor level up to second floor level

10.53

87668

8325.64

... More
Providing and laying Block Masonry with 100 mm thick (Autoclaved Aerated Cement) AAC blocks in super structure in cement mortar 1:4 (1 cement: 4 coarse sand). The rate includes providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of masonry work. (C) All works above second floor level up to third floor level

341.82

3036322

8882.81

... More
Brick work with common burnt clay (non modular) 1st class bricks in foundation and in plinth: (a) Cement mortar 1:4 (1 cement: 4 coarse sand)

2057.86

21765296

10576.65

... More
Providing and laying Block Masonry with 150 mm/ 230mm/ 300 mm thick (Autoclaved Aerated Cement) AAC blocks in super structure with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer In-charge. (The payment of RCC band and reinforcement shall be made for separately.) A) All works foundation, below plinth level and up to 1st floor level

1316.18

8314382

6317.07

... More
Providing and laying Block Masonry with 150 mm/ 230mm/ 300 mm thick (Autoclaved Aerated Cement) AAC blocks in super structure with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer In-charge. (The payment of RCC band and reinforcement shall be made for separately.) (B) All works above first floor level up to second floor level

557.64

3833345

6874.23

... More
Providing and laying Block Masonry with 150 mm/ 230mm/ 300 mm thick (Autoclaved Aerated Cement) AAC blocks in super structure with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer In-charge. (The payment of RCC band and reinforcement shall be made for separately.) (C) All works above second floor level up to third floor level

486.6

3616119

7431.4

... More
Providing 12mm thick cement plaster in a single coat on brick/ concrete walls for interior plastering finished with a floating coat of neat cement of mix C.M. 1:3 (1 cement : 3 sand) including providing and fixing 4/6 inch fibre mesh in CM 1:1 on concrete & brick junctions.

29506.95

9788930

331.75

... More
Providing 15mm thick cement plaster in a single coat on brick/ concrete walls for interior plastering finished with a floating coat of neat cement of mix C.M. 1:3 (1 cement : 3 sand) including providing and fixing 4/6 inch fibre mesh in CM 1:1 on concrete & brick junctions.

45780.09

17718727

387.04

... More
Providing 20mm thick cement plaster in a single coat on brick/ concrete walls for interior or exterior plastering finished with a floating coat of neat cement of mix C.M. 1:3 (1 cement : 3 sand) including providing and fixing 4/6 inch fibre mesh in CM 1:1 on concrete & brick junctions.

1318.86

598802

454.03

... More
Providing 18mm cement plaster in two coats underlayer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement: 6 fine sand) including providing and fixing 4/6 inch fibre mesh in CM 1:2 on concrete & brick junctions.

13372.36

4905516

366.84

... More
Pebble dash plaster upto all height/ level above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.

784.2

650846

829.95

... More
Finishing with Deluxe Multi Surface Paint System for interiors and exteriors using primer as per manufacturer's specification including scafolding upto all height/ level: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and one coat of special primer applied @ 0.75 ltr /10 sqm

16071.46

2187325

136.1

... More
Finishing walls with water proofing cement paint of required shade including scafolding upto all height/ level: New work (Two or more coats applied @ 3.84 kg/10 sqm)

8909.46

786259

88.25

... More
Providing and applying Plaster of Paris Putty/ Birla Putty of 2mm thickness over plastered wall surfaces to prepare surface even & smooth complete including scafolding upto all height/ level.

32780.85

5960214

181.82

... More
Wall painting with Premium Acrylic Emulsion Paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture including scafolding upto all height/ level , including applying primer and additional coats and wherever required to achieve even shade and colour. b) Two coats or more coats

35888.12

3625059

101.01

... More
Finishing with Deluxe Multi Surface Paint System for interiors and exteriors using primer as per manufacturer's specification including scafolding upto all height/ level: Painting wood work with Deluxe Mufti Surface Paint of required shade. Two or more coats applied @ 0.90 litre/10 sqm over an under coat of primer applied @ 0.75 Iitre/10 sqm of approved brand and manufacture.

268.8

41443

154.18

... More
Finishing walls with Textured Exterior Paint of required shade including scafolding upto all height/ level: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

134.4

31153

231.8

... More
Providing & laying Kota stone slab 25 mm thick flooring over 30 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 :4 (1 cement: 4 coarse sand). Wax polishing is strictly not allowed.

609.58

1385781

2273.34

... More
Providing & Laying Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Wax polishing is strictly not allowed.

529.47

1299933

2455.16

... More
Providing and laying Flamed finish Granite stone flooring / coping in required size, design, colour and patterns, in linear as well as curvilinear portions with approved finishes all complete as per the architectural drawings with 18-20 mm thick stone slab over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete as specified and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 18-20 mm thick Flamed finish Granite stone

12141.76

31726408

2613

... More
Providing and laying Flamed finish Granite stone for stone cladding, skirting, dado, steps, tread, risers, landing, wall lining, etc. laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand)/ ready mixed adhesive finishing and and cement slurry @ 3.3 kg/sqm including portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade complete at all levels as directed by Engineer In-charge and as per drawing. It includes grooves, moulding/ chamfering, rubbing, pointing, curing, half-round moulding and polishing etc. all complete as specified in architectural drawing and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 18-20 mm thick Flamed Granite stone

333.9

1175328

3520

... More
Providing and laying Polished finish Granite stone flooring / coping in required size, design, colour and patterns, in linear as well as curvilinear portions with approved finishes all complete as per the architectural drawings with 18-20 mm thick stone slab over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete as specified and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 18-20 mm thick Polished finish Granite stone

519.35

1430289

2754

... More
Providing and fixing Polished finsihed Granite stone for stone cladding, skirting, dado, steps, tread, risers, landing, wall lining, etc. over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade complete at all levels as directed by Engineer In-charge and as per drawing. It includes grooves, moulding/ chamfering, rubbing, pointing, curing, half-round moulding and polishing etc. all complete as specified in architectural drawing and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 18-20 mm thick Polished finish Granite stone

7255.56

26018438

3586

... More
Providing and laying Granite stone flooring in required colour, polish, size, design and patterns as per architectural drawing, in linear as well as curvilinear portions all complete as per the architectural drawings with 20mm thick stone slab over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete as specified and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 20 mm thick Granite stone

350

953050

2723

... More
Providing and laying Flamed finish Granite stone flooring / coping in required size, design, colour and patterns, in linear as well as curvilinear portions with approved finishes all complete as per the architectural drawings with 30 mm thick stone slab over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete as specified and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 30 mm thick Flamed finish Granite stone

20

92780

4639

... More
Providing and laying Granite stone flooring in required colour, polish, size, design and patterns as per architectural drawing, in linear as well as curvilinear portions all complete as per the architectural drawings with 30 mm thick stone slab over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete as specified and as directed by the Engineer-in-Charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 30 mm thick Granite stone

750

3368250

4491

... More
Providing and laying Polished finish Granite stone flooring / coping in required size, design, colour and patterns, in linear as well as curvilinear portions with approved finishes all complete as per the architectural drawings with 30 mm thick stone slab over 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with 5-8 mm gap as per design and drawing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per design and drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. all complete as specified and as directed by the Engineer In-charge. Including Minimum 2 mockups for approval, complete for finished item of work. Wax polishing is strictly not allowed. 30 mm thick Polished finish Granite stone

10

46050

4605

... More
Providing and fixing Granite cobble stones of size 100 x 100 x 100 mm of Black & Grey colors as approved by Architect, in approved pattern, laid on 20mm thick Cement mortar bed of proportion 1:6 and 6-10mm groove filling the joints with approved pigmented cement mortar in proportion 1:4, including grouting the joints in 1:2 proportion to match with the shade of respective stone, curing, polishing wherever applicable, cleaning, protecting etc. complete at all levels including fixing in cement mortar / ready mixed adhesive as approved and as directed by EIC.

2700

4414500

1635

... More
Providing and fixing 500 micron thick HDPE Membrane confirming to ASTM D5199 having density 0.94 gm/cm3 (ASTM D1505/D792) and low temperature brittleness -77 (ASTM D746). It shall possess tear resistence and puncture resistance of 73N and 200 N respectively and should contain carbon black content of 2-3%. The rate shall include all the fine grading/ levelling before fixing/ laying, jointing with heating technology, labour and machinery all complete as directed by the Engineer In-charge. Only plan area shall be measured and payable.

4971.24

487181

98

... More
Crazy Ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm, mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer In-charge.

1480

1055941

713.47

... More
Providing and laying Vitrified floor tiles (up to or 600mm x 600mm) in different sizes as per drawing with water absorption less than 0.08% and confirming to IS:15622, of approved make, in all colours and shades laid on 40 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete.

14567.16

19709367

1353

... More
Providing and laying Vitrified tiles (up to or 600mm x 600mm) in different sizes as per drawing in skirting, riser of steps, dado with water absorption less than 0.08% and confirming to IS:15622, of approved make, in all colours and shades laid on 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.

4037.8

5870961

1454

... More
Providing and fixing tactile studs and strips of stainless steel 316 grade (4nos strips in 300 x 300mm or 36nos studs in 300 x 300mm) designed to help the blind and visually impaired people and provide an anti-slip surface for all pedestrians as per drawing with required cuttings, holes, anchor fasteners, screws, fittings and required accessories etc. complete as per IS 15622:2017 and IRC:103-2012 standards as directed by Engineer In-charge.

800

1472000

1840

... More
Providing and laying damp proof course (DPC) with 25mm thick cement concrete in proportion 1:1.5:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.

1717.86

686799

399.8

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300 x 300 x 9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 30 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer In-charge.

614.44

2065839

3362.15

... More
Providing and applying anti-skid Polyurethane based Car Park flooring system: Surface preparation by using high end grinding, surface profile machines using diamond tools, scarifier and vacuum assisted system to achieve the profile with no undulations as approved. If any part of the floor is contaminated by grease/ oil, the contamination shall be removed before other forms of preparation is undertaken. Remove all laitance and weak or friable concrete to create a profile for better bonding, opening of cracks & cold joints by groove cutter machine/ manual preparation which needs to repair by using suitable epoxy putty or epoxy mortar as per site requirement, followed by providing & applying high build epoxy based primer, having Bond strength 1.5 Mpa (Concrete Failure), Flexural strength 45 Mpa, compressive strength 35 Mpa, Tensile strength 25 Mpa, to be applied @ 0.2-0.3 litre/sqm, immediately followed by providing & applying blind anti slip grains in wet condition, to be applied @ 4-6 Kg/sqm, allow the coating to dry for 14-16 Hrs, followed by providing & applying 2 coats of intermediate (as per RAL shade) PU coat, to be applied by roller of 1mm thickness, allow the coating to dry for 18-24 Hrs, followed by providing & applying final PU coat, to be applied 100 microns per coat, allow the coating to dry for 18-24 Hrs.

4575.66

7375963

1612

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes.

3325.01

12444900

3742.82

... More
Providing and applying Stencil works for 200 microns Line Markings in Car Park areas using approved product of Polyurethane based coating using paint brush/ woolen roller, etc. The shall inclusive of all application tools and plants, all lead and lift, all height and level, all material, labour, etc. complete as per manufacturer`s standard and as directed by EIC. The required properties shall be as per ASTM/ BS-EN/ DIN Standards. (i.e. Signages for Speed Breakers, Electric Vehical, Turn arounds, Disabled Parking Bay, Way finding Arrows, Stop, Entry, Exit etc.) as per stencil patterns, colours and approved drawings.

457.57

70556

154.2

... More
Deck Flooring (WPC): Providing and fixing Deck flooring / coping made from high class Wood Plastic Composite (WPC) Panels made from 55%, Wood 35% High grade polymer (HDPE) and 10% Additives like bonding stabilizer, UV stabilizer etc. and the material should follow ASTM D 570, ASTM D 1894, ASTM D 256, ASTM D 790, ASTM D 1525, ASTM D 648, ISO 9352, IS 14887:2000. It should be weatherproof and suitable to be used in outdoor spaces with temperature ranging between -40 ˚C to 60 ˚C. WPC decking section should have bulk density of 1.2 g/cm3. Wood Polymer Composites products must be certified as Green Product by IGBC. WPC decking have thickness 23mm and width 145mm (145x23mm). The rates are inclusive of all lead and lift, all floor levels, all heights, all material and accessories like anchor fastners, scaffolding, labour etc. complete in all respects.

1251.25

6049769

4835

... More
Providing and laying 80mm thick Paver over a base of 100 mm compacted sand gravel including cutting where necessary finished with flush pointing with cement slurry mixed with approved pigment to match shade of pavers complete at all levels as specified and directed.

4195.51

4041744

963.35

... More
Providing and laying 60mm thick Paver over a base of 100 mm compacted sand gravel including cutting where necessary finished with flush pointing with cement slurry mixed with approved pigment to match shade of pavers complete at all levels as specified and directed.

300

252640

842.13

... More
Providing and laying 500 x 500 x 40mm thick Turf Paver (Turf pave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer In-charge.

1850

3271295

1768.27

... More
Providing, supplying, fitting, fixing and laying of 100mm thick dressed stone block flooring (cherra/ local stone block) in required sizes, shapes and pattern as per drawing laid on 25mm thick base in cement mortar 1 :3 and jointed with grey cement slurry including clearing, rubbing, etc. complete as directed.

1892.3

7748529

4094.77

... More
Providing and fixing Precast Kerb blocks of various types (Half Batter, Bull Nose, Flat, Offlet, Transition, Dropper, etc.) and size of 600 x 450 x 150mm steel mould vaccum wet pressed for connecting roads, pathway, prominade and other areas with true line & level, including grading, geometrical shapes in curves, circles etc. at respective finish level etc. completed as specified in drawing and specification. It shall be M25 grade of cement concrete and fitted/ jointed in C:M 1:1 with throughly curing, rendering with cement slurry, cleaning the joints neatly etc. completed as directed by EIC. It allows to satisfy respective IS codes for materials, manufacturing process and test results.

2670

4704540

1762

... More
Providing and fixing Precast Kerb blocks of various types (Half Batter, Bull Nose, Flat, Offlet, Transition, Dropper, etc.) and size of 600 x 300 x 150mm steel mould vaccum wet pressed for connecting roads, pathway, prominade and other areas with true line & level, including grading, geometrical shapes in curves, circles etc. at respective finish level etc. completed as specified in drawing and specification. It shall be M25 grade of cement concrete and fitted/ jointed in C:M 1:1 with throughly curing, rendering with cement slurry, cleaning the joints neatly etc. completed as directed by EIC. It allows to satisfy respective IS codes for materials, manufacturing process and test results.

910

1095640

1204

... More
Supplying, providing and applying Stonecrete or Grit Wash Flooring of approved colour, shape and pattern as per drawing, in 2 layers, underlayer 12 mm cement plaster 1 :4 (1 cement: 4 coarse sand), furrowing the underlayer with scratching tool, applying cement slurry on the underlayer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:0.5:2 (1 cement: 0.5 dolomite powder: 2 stone chippings 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer In-charge. The rate shall be inclusive of requried grooves, shapes and patterns with required batten and dolomite powder to increase the strength of flooring.

350

1264718

3613.48

... More
Providing and laying Stone/ Boulder pitching on slopes laid over prepared filter media as per drawing and Technical Specifications Clause 1302.

1190.13

3053567

2565.74

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and Technical Specification Clause 1302.

4323.79

13378683

3094.2

... More
Providing and laying filter media with granular crushed aggregates as per specification with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Technical Specification Clause 1204.3.8.

4188.98

12226627

2918.76

... More
Design, fabrication, supply, installation & fixing of Aluminium Work for door, window, partition, curtain wall, facade and cladding etc. with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make confirming to IS:733, IS:1285 and aluminium quality as per grade 6063 T5 or T6 as per BS 1474, fixing with dash/ anchor fasteners of required diameter and size, including necessary filling up the gaps with weatherproof structural sealant at junctions (i.e. at top, bottom and sides) and required microwave cured EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, sleeves, cover plate, space plate, extensions, C.P. brass/ stainless steel screws, etc. all complete as per architectural intent drawings, approved shop drawings submitted by Contractor and the directions of Engineer In-charge. The rate shall include all design, engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, buffer plates, fastener, anchors, SS channel for glass etc. all complete. Contractor shall arrange minimum 2 mock-ups at site without extra charge and get it approved from Architect & Engineer In-charge. (Glazing, cladding and panelling to be paid for separately): Minimum thickness of 80-micron Super Durable Powder Coated Aluminium confirming to AAMA 2604 of required colour/ shade as approved by Architect- 10 years Guarantee shall have to require for complete system inclusive of powder coating life.

57850.34

27373043

473.17

... More
Providing and fixing Glazing in door, window, partition, curtain wall, facade, roofing and cladding etc. with microwave cured EPDM rubber/ neoprene gasket and filling gap/ jointing with weatherproof structural sealant as directed etc., in required holes, sizes and shapes complete as per the architectural drawings and the directions of Engineer In-charge: (A) 5mm clear toughen glass + 1.52mm physical vapor deposition lamination system + 6mm clear toughened glass system

1903.01

11216340

5894

... More
(B) 12mm clear toughen glass

3060.36

10824493

3537

... More
(C) 12mm reflective toughen glass as per colour selection by Architect

3124.27

13943617

4463

... More
(D) 6mm clear toughened glass

376.59

709879

1885

... More
Openable side/ top hung System: 12mm reflective toughen glass as per colour selection by Architect including providing and supplying at site all accessories and hardware for the openable panels as specified and of the approved make such as heavy duty stainless steel top/ side hung friction hinges, min 4-point cremone locking sets with stainless steel plates, handles, buffers, microwave cured EPDM rubber/ neoprene gasket and filling gap/ jointing with weatherproof structural sealant as directed etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer In-charge.

842.24

6005078

7129.89

... More
Openable side/ top hung System: 6mm clear toughened glass including providing and supplying at site all accessories and hardware for the openable panels as specified and of the approved make such as heavy duty stainless steel top/ side hung friction hinges, min 4-point cremone locking sets with stainless steel plates, handles, buffers, microwave cured EPDM rubber/ neoprene gasket and filling gap/ jointing with weatherproof structural sealant as directed etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer In-charge.

1516.67

8308151

5477.89

... More
Design, fabrication, supply, installation & fixing of Aluminium Work for door, window, partition, curtain wall, facade and cladding etc. with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make confirming to IS:733, IS:1285 and aluminium quality as per grade 6063 T5 or T6 as per BS 1474, fixing with dash/ anchor fasteners of required diameter and size, including necessary filling up the gaps with weatherproof structural sealant at junctions (i.e. at top, bottom and sides) and required microwave cured EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, sleeves, cover plate, space plate, extensions, C.P. brass/ stainless steel screws, etc. all complete as per architectural intent drawings, approved shop drawings submitted by Contractor and the directions of Engineer In-charge. The rate shall include all design, engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, buffer plates, fastener, anchors, SS channel for glass etc. all complete. Contractor shall arrange minimum 2 mock-ups at site without extra charge and get it approved from Architect & Engineer In-charge. (Glazing, cladding and panelling to be paid for separately): Minimum anodic coating of grade AC 15 of Anodised aluminium according to IS:1868 of required transparent/ colour/ shade as approved by Architect- 10 years Guarantee shall have to required for complete system inclusive of powder coating life.

22702.94

9969837

439.14

... More
ACP Cladding: Designing, fabricating, testing, installing, and fixing in position Aluminium Composite Panel cladding, with open groves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including aluminium composite panel cladding, cleaning, and protection of the curtain wall till the handing over of the building for occupation. (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating, supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm think FB grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The ACP cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumi Flon based fluoropolymer resin coating of approved colour and shade on face #1 and polymer (Service) coating on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins, and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of minimum two mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working aluminium composite panel cladding, cleaning, and protection of the aluminium composite panel cladding till the handing over of the building for occupation. Base framework for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer In-charge. However, tor the purpose of payment, only the actual area on the external face of the with ACP Cladding including width of shall be measured in sqmt.

1034.34

5775121

5583.39

... More
Fluted ACP Cladding: Designing, fabricating, testing, installing, and fixing in position Aluminium Composite Panel cladding in fluted pattern, with open groves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including aluminium composite panel cladding, cleaning, and protection of the curtain wall till the handing over of the building for occupation. (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating, supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm think FB grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The ACP cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumi Flon based fluoropolymer resin coating of approved colour and shade on face #1 and polymer (Service) coating on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins, and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of minimum two mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working aluminium composite panel cladding, cleaning, and protection of the aluminium composite panel cladding till the handing over of the building for occupation. Base framework for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer In-charge. However, tor the purpose of payment, only the actual area on the external face of the with ACP Cladding including width of shall be measured in sqmt.

5675.74

34936668

6155.44

... More
Aluminium Box type/ Z type/ A type/ convex type/ ellipse type Fixed Louver System: Design, Fabrication, Supply, Installation & Fixing of aluminium horizontal/ vertical louver (drainable style blade) system made in box pipes, Z type, A type and other required sections as designed to withstand wind pressure considering rainy scenario of site. Complete system shall be fixed on RCC/ Structural Steel including necessary filling up the gaps with weatherproof structural sealant at junctions (i.e., at top, bottom and sides), microwave cured EPDM rubber/ neoprene gasket and necessary screw and anchor fasteners in SS 316 etc. The extruded aluminium sections of Alloy 6063 T5/ T6 and tolerances confirming to EN standard from approved extruder only. Contractor shall arrange minimum 2 mock-ups at site without extra charge and get it approved from Architect & Engineer Incharge. All surfaces shall have minimum thickness of 80-micron Super Durable Powder Coated Aluminium confirming to AAMA 2604 of required colour/ shade as approved by Architect- 10 years Guarantee shall have to require for complete system inclusive of powder coating life.

9024.3

5414580

600

... More
Motorized Operable Aluminium Box type/ Z type/ A type/ convex type/ ellipse type Louver System: Design, Fabrication, Supply, Installation & Fixing of aluminium horizontal/ vertical openable louver (adjustable drainable style blade) system made in box pipes, convex type, ellipse type, Z type, A type and other required sections as designed to withstand wind pressure considering rainy scenario of site. Contractor must design motor and related assembly for different louver modules as per design intent. Complete system shall be fixed on RCC/ Structural Steel including necessary filling up the gaps with weatherproof structural sealant at junctions (i.e., at top, bottom and sides), microwave cured EPDM rubber/ neoprene gasket and necessary screw and anchor fasteners in SS 316 etc. The extruded aluminium sections of Alloy 6063 T5/ T6 and tolerances confirming to EN standard from approved extruder only. Contractor shall arrange minimum 2 mock-ups at site without extra charge and get it approved from Architect & Engineer Incharge. All surfaces shall have minimum thickness of 80-micron Super Durable Powder Coated Aluminium confirming to AAMA 2604 of required colour/ shade as approved by Architect- 10 years Guarantee shall have to require for complete system inclusive of powder coating life.

1020

1092420

1071

... More
Dry Wall: Providing and fixing partition up to ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm (both sides inclusive), consisting of floor and ceiling channel 72 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 70 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia. bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm (both sides inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25x25x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of Engineer In-charge all complete: 100mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG), plaster board conforming to lS:2095: (part 3) 1996 (Board with BIS Certification marks).

2793.82

5774993

2067.06

... More
Deck Sheet: Providing and fixing roofing consisting of 1 mm thick galvanized steel deck sheet confirming to IS:277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100 x 100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel beam, column, joists etc. & concrete of different grade as per design will be paid separately.)

6632.16

18039472

2720

... More
Aluminium Standing Seam Roofing System with Flashing, Skylight, Gutter, Fall Protection System for maintenance, Step Walkway System for maintenance: Designing, fabricating, testing, installing and fixing in position Double Skin Roofing System of straight & tapered sheets with 2 coats of PVDF coating. The roofing system will have required minimum thermal conductivity of 0.034 W/m-K as per ASTM C518, U Value of 0.35 W/m²-K, R Value of 3 m²-K/W, Sound Transmission Class (STC) rating of 50 dB as per International Building Codes and wind pressure as per site weather condition. Top Layer: Aluminium Standing Seam SF 65/400 in self-supported fix roofing system in 1mm thick is profiled on site with Aluminium Halter (Straight/ Tapered/ Curved/ Infinity). Halter to be fixed on purlins or brackets with SS 304 screws. The feed material for top skin is manufactured out of nominal 1mm thick AA 3004 aluminium alloy in 2 coats of 25microns PVDF finish (colour as per Architect approval). The profile panels should have 3nos of mini ribs for extra strength. The roof element will be supported and joined longitudinally with an electrically operated closure zipping machine over concealed extruded secret halter integrated into the longitudinal element flanges thereby allowing for the possibility of transmitting reaction forces resulting from positive and/or negative loads, accommodating unobstructed thermal movements resulting from the specified ambient temperature variation and other loads as per IS codes. The sheet to be laid as per the requirement of building geometry provided by Architect. Second Layer: 100mm thick 2-hour Fire rated Rockwool insulation of 100 kg/cum density conforming to IS 8183. The insulation must be certified by EUCEB as non-carcinogenic, bio soluble and also comply to the Building Standard considering Fire Performance of EN 13501-1 Non-combustible/ Euro Class A1, BS 476 Part 4 Non-combustible. BS 476 Part 6 Fire Propagation, BS 476 Part 7 Surface Spread of Flame, UL 723– SDI & FSI 0 (Xero) Melting Point ASTM E794 1000ºC. Third Layer: Top Hat Bracket of 2mm made from GI steel sheet. Fourth Layer: Top Hat Batten made from 2mm GI steel sheet to be fixed above the 0.5mm liner sheet.

9466

134824238

14243

... More
Fifth Layer: Vapour Control Layer is a reinforced polythene va`pour barrier of double sided aluminium foils of 200 microns with Moisture Vapor Transmission Rate (MVTR) of 343 MN.s/g and water permeability of 0.7 g/m2/day Sixth Layer (Bottom Sheet): Trapezoidal Galvalume minimum thickness of 0.50mm (TCT) profile sheet of 980-1250 mm effective cover width and 28-35 mm height ribs with pitch at 200-250 mm centre-to-centre using self-drilling/ self-tapping zinc coated/ S.S. screws of required size with EPDM seal complete up to any pitch in Straight/ Tapered/ Curved/ Infinity surfaces. The complete system must be waterproof with 10 years guarantee. The rates shall inclusive of wind clamps, anchor fasteners, halters, 1mm thick aluminium flashing in 2 coats of 25microns PVDF finish at all edges, opening/ skylight provision of addition 2mm thick aluminium flashing in 2 coats of 25microns PVDF finish, 2mm thick aluminium gutter (up to 1200mm) in 2 coats of 25microns PVDF finish with down take spouts, fall protection system for maintenance, step walkway system at centre for maintenance, double side vulcanized rubber expansion joints, rockwool insulations and other required hardware/ accessories like cover plate, end caps, welding at joints etc. for complete system in all areas, periphery, sides and edges etc. Aluminium standing seam complete system with maintenance provisions rate shall be measured in square metre of top surfaced planned area.

-

-

-

... More
Designing, fabricating, testing, installing and fixing of Roof Hatch of 2.3 mm thick Aluminium in 2 coats of 25microns PVDF finish single leaf opening of size 914mm x 914mm cover and frame in 55mm concealed with 50mm rockwool insulation of 100 kg/cum density, fully welded at all corners, internally reinforced for live load curb height with integral cap flashing, microwave cured EPDM rubber gasket for water tightness, mounting flange for securing hatch to roof, SS 316 grade heavy duty pintle hinge, heavy duty 4 point lock system with all lead and lift including other required hardware/ accessories like cover plate, end caps, welding at joints etc. for complete system in all areas, periphery, sides and edges etc. as directed by the Engineer In-charge.

8

3146828

393353.59

... More
Providing ridges or hips of width 60 cm overall width L shaped moulded 0.8 mm thick Aluminium in 2 coats of 25 microns PVDF finish as per drawing fixed with polymer/ zinc coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.

423.76

330725

780.46

... More
Zinc Titanium Standing Seam Roofing System with Flashing: Designing, fabricating, testing, installing and fixing of 25/430 zinc titanium double lock standing seam roofing system (thickness: 0.8mm) with crest height of 25 mm thick consisting of fixing clips made of stainless steel to connect the zinc panel to the hat section comprising of the following layers. The zinc roof cladding system shall consist of the following elements to form a rigid, non-ventilated and watertight support base for installation of the pre weathered quartz zinc roofing sheets. The roofing system will have required minimum thermal conductivity of 0.034 W/m-K as per ASTM C518, U Value of 0.35 W/m²-K, R Value of 3 m²-K/W, Sound Transmission Class (STC) rating of 50 dB as per International Building Codes and wind pressure as per site weather condition. i) Top Layer: Zinc Titanium standing seam profiled panels 25/430 (25 mm minimum seam height & 430 mm panel width) manufactured from zinc titanium alloy in pre-weathered quartz finish in 0.8 mm minimum thickness as per EN 988 standards (Straight/ Tapered/ Curved/ Infinity). The material properties shall be as follows: Ultimate tensile strength: min 150 N/mm2, 0.2% Proof Stress: min 100 N/mm2, Panels shall be fixed to the substructure using stainless steel clips & sliding clips of suitable height with spacing as required for the wind loads. The zinc roofing sheets shall have a protective coating at the underside coated with transparent polyurethane primer (thickness 25 microns) as an adhesive layer of corrosion protection and highly durable polyurethane-polyamide organic top finsh coats (thickness 60 microns of the two coats). The roof element will be supported and joined longitudinally with an electrically operated closure zipping machine. The sheet to be laid as per the requirement of building geometry provided by Architect. ii) Second Layer: Anti abrasive breathable membrane laid at the underside of zinc panels. An Abrasive membrane to be laid underneath the roofing sheets. High Density polyethylene underlay membrane of 0.6 mm with studs of 8.0 mm spaced at 19.5mm. Membrane shall have compression resistance of 250 KN/m². It shall have stud free lateral edge of 100 mm for overlap of membrane. It should be chemically and electrically neutral, resistant to mould and chemical aggressions, It should be stabilized for thermal cycles and dimensionally stable between (-30°C & 80°C). iii) Third Layer: 1.5 mm thick GI strips to place at distance of min. 430 mm for fixing of clips. iv) Fourth Layer: 0.47 mm Hi-Tensile steel coated sheets profile with nominal 3.0-4.0 mm deep ribs at pitch of nominal 48 to 52 mm centre to centre distance 550 MPa Yield Strength

673.12

5225094

7762.5

... More
v) Fifth Layer: Z GIRT- Sub girt in Z-section 2.0 mm thick in galvanized steel 275 gsm fixed to steel purlins through bottom sheet. vi) Sixth Layer: Insulation- 100mm thick 2-hour Fire rated Rockwool insulation of 100 kg/cum density conforming to IS 8183. The insulation must be certified by EUCEB as non-carcinogenic, bio soluble and also comply to the Building Standard considering Fire Performance of EN 13501-1 Non-combustible/ Euro Class A1, BS 476 Part 4 Non-combustible. BS 476 Part 6 Fire Propagation, BS 476 Part 7 Surface Spread of Flame, UL 723– SDI & FSI 0 (Xero) Melting Point ASTM E794 1000ºC. Insulation shall have one side aluminium foil to act as vapor barrier. vii) Seventh Layer: Bottom sheet- Trapezoidal Galvalume minimum thickness of 0.50mm (TCT) profile sheet of 980-1250 mm effective cover width and 28-35 mm height ribs with pitch at 200-250 mm centre-to-centre using self-drilling/ self-tapping zinc coated/ S.S. screws of required size with EPDM seal complete up to any pitch in Straight/ Tapered/ Curved/ Infinity surfaces. The complete system must be waterproof with 10 years guarantee. The rates shall inclusive of wind clamps, anchor fasteners, halters, 1mm thick Zinc Titanium flashing at all edges, double side vulcanized rubber expansion joints, rockwool insulations and other required hardware/ accessories like cover plate, end caps, welding at joints etc. for complete system in all areas, periphery, sides and edges etc. Zinc Titanium Standing seam complete system with Flashing rate shall be measured in square metre of top surfaced planned area.

-

-

-

... More
Providing & fixing of Zinc Titanium 1mm thick flashing for Skylight: Skylight flashings manufactured from 1mm thick Zinc Titanium in pre-weathered quartz finish on exposed surface as per EN 988 standards. The material properties shall be as follows: Ultimate tensile strength: min 150 N/mm2, 0.2% Proof Stress: min 100 N/mm2, Panels shall be fixed to the substructure using stainless steel clips & sliding clips of suitable height with spacing as required for the wind loads. The zinc roofing sheets shall have a protective coating at the underside coated with transparent polyurethane primer (thickness 25 microns) as an adhesive layer of corrosion protection and highly durable polyurethane-polyamide organic top finsh coats (thickness 60 microns of the two coats). The cutout shall have to design for 12mm fixed polycarbonate sheet on roofing surface as per design intent and get it approved from Architect & Engineer In charge. Approx. 600mm girth material to be required for flashing of skylight. Rate shall be inclusive of fixing with dash/ anchor fasteners of required diameter and size, including necessary filling up the gaps with weatherproof structural sealant at junctions (i.e. at top, bottom and sides) and required microwave cured EPDM rubber/ neoprene gasket etc.

15.9

25898

1628.4

... More
Polycarbonate Roofing Sheet in Zinc Titanium Standing Seam Profile: Providing and fixing 12 mm thick Polycarbonate single/ multi wall roofing sheet for day lighting fixed with hilti screw and rubber silicon sealer and alluminium strip of size 50 x 3 mm etc complete as directed by Engineer In-charge. Rate shall be inclusive of fixing with dash/ anchor fasteners of required diameter and size, including necessary filling up the gaps with weatherproof structural sealant at junctions (i.e. at top, bottom and sides) and required microwave cured EPDM rubber/ neoprene gasket etc.

15.06

43008

2855.24

... More
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain 0.8mm thick Zinc Titanium finish G.S. sheet Gutter with iron brackets 40x3mm size, bolts, nuts and washers, etc., including making necessary connections and spouts provision for rain water pipes complete.

69.3

52391

756.01

... More
Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer In-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in 240 Mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 meter or as desired by Engineer In-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5 x 55 mm) with EPDM seal or bolts and nuts 8 mm diameter with bitumen or G.I. limpet washers filled with white lead, complete up to any pitch in horizontal, vertical or curved surfaces, excluding the cost of purlins. rafters and trusses and including cutting to size and shape wherever required.

919.74

695328

756.01

... More
Thatch Roofing: Providing and fixing 150mm thick thatch roofing with sun grass in layer of 75 mm thick with half spilt bamboo fillet and tying with galvanised wire complete as directed.

919.74

309032

336

... More
Aluminium Baffled False Ceiling: Providing and fixing 0.65mm thick Aluminium Baffled False Ceiling using rectangle panels of 25mm wide and 100mm deep of Aluminium alloy like AA-8011. The two panels to be joined together by means of panel coupler suitable for U Shaped Screen Panel. The aluminium coil panel shall be chromium coated from inside and powder coated in minimum 80microns on exposed outside surface of required colour shade as approved by Architect. The carrier profile, carrying channel support, GI bracket, joint splice, spring clips, hanger, anchor fastener and SS screws to be provided as per manufacturer specification/ system and get it approved from Architect & Engineer Incharge. The distance between the modules is 100mm centre-to-centre. The carrier profile to be suspended from slab/ truss by galvanized rod/ hanger with required size of chemical/ mechanical anchor fastener & height adjustment powder coated spring clips at maximum 1-meter centre-to-centre. Contractor shall arrange minimum 2 mock-ups at site without extra charge and get it approved from Architect & Engineer Incharge.

4650.11

50121951

10778.65

... More
Providing and fixing false ceiling of 12.5 mm thick tapered edge gypsum moisture resistant board of any shape, size, curvature, pattern as per drawing at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per lS:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia. x 50mm long with 6 mm dia. bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45 x 15 x 0.9 mm running at the spacing of 1200 mm centre to centre, to the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, Shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia. x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fb(ed to walvpartition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm a/c, including jointing and finishing to a flush finish Of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides ol joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer In-charge but excluding the cost of painting.

26107.2

30924392

1184.52

... More
Providing and fixing anodised aluminium work (anodised transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) consisting of tee/ angle sections, of approved make conforming to IS:733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 10 mm diameter with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer In-charge. Only aluminium framing section weight shall be measured and paid, but rate shall be inclusive of level adjusting hangers, ceiling cleats and expansion hold fasteners/ anchor fasteners fixing on MS/ concrete surface.

28146.48

21847551

776.21

... More
Providing and fixing false ceiling of 6mm thick gloss/ matt/ suede finish Exterior Grade High Pressure Compact Laminate board of any shape, size, curvature, pattern, groove as per drawing, made out of urea free, thermosetting phenolic resins treated kraft papers as core material and amino plastic resin treated decor papers along with UV protection film on both side finish surfaces. Board should confirm to European Fire Rating norms of BS1,d0 classified in accordance with EN 13501-1: 2007. It should have antibacterial and antifungal properties (conforming to JIS Z2801:2010 and ASTM G21-2015 standards respectively). Board should have density 1350 kg/m3, anti-graffiti properties and resistant to take climatic shock, UV light, grey scale contrast (1500 hours of exposure rating-4), artificial weathering (including light fastness) with a grey scale rating not worse than 4 after exposure to 650 MJ/m2, acid rain, corrosion (on a salt spray test for 700 hours) as per applicable specifications conforming to latest and applicable EN 438-6: 2016 EDF grade quality standards. It should be CE certified for constancy of performance described by the standard EN 438-7:2005. The product should be warranted against manufacturing defects and performance characteristics for a period of 10 years. Ceiling board should be installed on MS/ alumnium tubular substructure as per site requirement at 450 mm c/c distance with the help of 5mm diameter colour matching rivets as per manufacturer specification.

9382.16

50710574

5405

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage on a Rs.100/- stamp paper in approved proforma. (1) For vertical surface two coats @0.70 kg per sqm per coat

8386.91

3966170

472.9

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage on a Rs.100/- stamp paper in approved proforma. (2) For horizontal surface one coat @1.10 kg per sqm.

19055.16

6913212

362.8

... More
Toilet Sunk Water Proofing: Providing and carry out waterproofing treatment to sound concrete surface of toilets sunken slabs, corridors, wet areas etc. after proper surface preparation to remove loose dust, dirt etc., repairing of cracks (if any) using polymer modified mortar, carry out cementitous injection grouting at leakage points modified with Plasticised Expandive Grout Admixture @ 225 gms per bag of cement, carry out 50 mm thick cement mortar (1:3) vatta/ corner modified with Styrene Butadine Polymer bonding agent at dosage of 2.5 litre per 50 kg cement, pre-dampening concrete surface, mixing and application of two coats of Elastomeric Polymer modified cementitious waterproofing coating by incorporating 45 gsm glass fibremesh between 1st and 2nd coat using suitable brush or roller as per coverage etc. complete including all tools and tackles as per manufacturer’s specification. Cured Polymer modified cementitious waterproofing coating shall comply with ASTM D4060, ASTM D4541, ASTM D638,ASTM C836 and possess below properties: Mixed density: 1.68 g/cc, Adhesion to concrete- 1 N/mm2, Non-toxic, Static crack accommodation-1 mm. Water proofing system shall be executed by only approved applicator of approvd brand and under strictly supervision of techanical fellow of manufacturer. The product performance shall carry guarantee for 10 years against any leakage on a Rs.100/- stamp paper in approved proforma.

1136.16

458440

403.5

... More
Providing and fixing 50 mm thick fire resistant single or door shutters including provision of fire rated vision glass panel of 120 minutes fire rating conforming to IS:3614 (Part-11), tested and certified as per laboratory approved by Engineer In-charge, with suitable mounting on fire rated door frame of 100 x 57 mm made out of 1.6 mm thick fixed with intumescent fire seal strip of size 10 x 4 mm (minimum) all round the frame and fixing by M10 x 100 or required size anchor fasteners, consisting of vertical stiles, lock rail, top rail 100 mm wide or as per manufacturer, bottom rail 200 mm wide or as per manufacturer, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled FR insulation material and fixing with necessary 4 nos stainless steel 316 grade ball bearing hinges as per total weight of shutter, stainless steel 304 grade mortise dead lock for single/ double shutter, panic bar/ latch (double point) fitted with a single body, trim latch & lock on back side of the panic latch for single/ double shutter, push-pull stainless steel 316 grade handle 'H' Ø 25 mm x 250mm x 350 mm door handles, stainless steel 304 grade 400mm square tower bolt, heavy duty door closer as per total shutter weight, fire seal for grooved frame and necessary accessories i.e. screws, bolt etc. of Dorma, Kich, Godrej or approved make only, including applying a coat of approved fire resistant powder coating of not less than 50 micron in desired shade as per the directions of Architect etc. all complete.

45

354923

7887.18

... More
Providing and fixing 50 mm thick fire resistant single or door shutters including provision of fire rated vision glass panel of 60 minutes fire rating conforming to IS:3614 (Part-11), tested and certified as per laboratory approved by Engineer In-charge, with suitable mounting on fire rated door frame of 100 x 57 mm made out of 1.6 mm thick fixed with intumescent fire seal strip of size 10 x 4 mm (minimum) all round the frame and fixing by M10 x 100 or required size anchor fasteners, consisting of vertical stiles, lock rail, top rail 100 mm wide or as per manufacturer, bottom rail 200 mm wide or as per manufacturer, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled FR insulation material and fixing with necessary 3 nos stainless steel 316 grade ball bearing hinges as per total weight of shutter, stainless steel 304 grade Allen key lock for single/ double shutter, stainless steel 304 grade indicator bolt, fire seal for grooved frame and necessary accessories i.e. screws, bolt etc. of Dorma, Kich, Godrej or approved make only, including applying a coat of approved fire resistant powder coating of not less than 50 micron in desired shade as per the directions of Architect etc. all complete.

185

875475

4732.3

... More
Providing and fixing glass of required thickness having 120 minutes of fire resistance both integrity and radiation control (EW60) glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c, including applying a coat of approved fire resistant powder coating of not less than 50 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size eta. complete in all respect as per NBC 2016, IS:16231 (Part 3):2016 and as per direction Of Engineer In-charge. The manufacturer have to give test report/ certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025 for testing and calibration.

26

1090820

41954.63

... More
Providing & fixing 12mm thick frameless clear toughened glass door shutter of approved brand and manufacture, including providing & fixing top & bottom pivot & double acting heavy duty hydraulic floor spring with SS 316 grade steel cover plate, Push-Pull SS 316 grade Handle 'H' Ø 25 mm x 250mm x 350 mm Door handles, Door lock of SS 304 grade for single/ double shutter at bottom, Door Stopper of SS 316 grade and other necessary accessories such as type fixing arrangement and making necessary holes etc. of Dorma, Kich, Godrej or approved make only, fixing required door fittings, all complete as per direction of Engineer In-charge.

920

8168680

8879

... More
Providing and fixing ISI marked 35 mm thick flush door shutters with lipping wooden battens 25 mm minimum depth on all edges conforming to IS:2202 (Part I) decorative type, core of block board construction with seasoned wood frame of 1st class hard wood of 100 x 60 mm with required groove and well matched teak 3mm ply veneering with vertical/ horizontal grains or cross bands and face veneers on both faces of shutters including 2 or 3 coats of polishing/ varnishing on frame and shutter, 4 nos stainless steel 316 grade ball bearing hinges as per total weight of shutter with necessary screws and accessories of Dorma, Kich, Ebco or other approved make as selected by Architect.

335.52

1038880

3096.33

... More
Push-Pull Handle: Providing and fixing of stainless steel SS 316 grade 'H' Ø 25 mm x 250mm x 350 mm Door handles of Dorma, Kich, Ebco or other approved make & quality complete as directed by Engineer In-charge and as selected by Architect.

202

402990

1995

... More
Hydraulic Door Closer: Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer as embossed on the body, door weight up to 36 kg to 80 kg, with double speed adjustment with necessary accessories and screws etc. of Dorma, Kich, Ebco or other approved make complete as directed by Engineer In-charge and as selected by Architect.

101

89565

886.79

... More
Morticed Lock: Providing and fixing heavy duty SS finish concealed type mortice lock with SS 304 grade 19 dia. handle for single/ double leaf door (wooden, metal or aluminium etc.) with set of 4 keys and master key lock, openable from one/ double side by the key, SS 304 grade cover plates includes all necessary fittings and accessories etc. of Dorma, Kich, Ebco or other approved make, complete as directed by Engineer In-charge and as selected by Architect.

101

269064

2664

... More
Square Tower Bolt: Providing and fixing stainless steel 304 grade 400mm square tower bolt, includes all necessary fittings and accessories etc. of Dorma, Kich, Ebco or other approved make, complete as directed by Engineer In-charge and as selected by Architect.

50

33950

679

... More
Urinal Partitions: Providing and fixing 12mm thick pre-laminated HPL boards for toilet urinal partitions as per the drawing and as per the selection by Architect. It includes SS sections or powder coated aluminium framing, SS clamps, SS fittings and other accessories, etc. as selected by Architect.

30.76

365920

11896

... More
Toilet Cubicles: Providing and fixing 12mm thick pre-laminated HPL boards for fixed cubicle and door shutter as per the drawing and as per the selection by Architect. It includes SS hinges, SS framing, SS post, SS clamps, SS fittings, SS lock, SS Indicator bolt, SS knob, SS hook and other accessories, SS door accessories, etc. of Merino, Greenlam or other approved make as per requirement. It includes minimum 1 mock-ups for approval and complete system as per manufacturer's specification.

119

4771900

40100

... More
Supplying and fixing rolling shutters including ball bearing of approved make, made of required size 80 x 1.20mm M.S. laths, interlocked together through their entire length and jointed togather at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements tor inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part 1) and 1.20mm thick M.S. top cover for rolling shiitters.

2304.48

9458381

4104.34

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters.

2304.48

2737049

1187.71

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer In-charge. (area of grill to be measured only).

460.9

327859

711.35

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910, on 12 mm dia. steel bar conforming to IS:1786, having minimum cross section as 23x25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manutacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) complete as per design.

150

64117

427.45

... More
Stainless Steel Sign Boards: Providing and fixing 2mm thick sign boards in stainless steel 304 grade in required size and shape as per the details shown in drawing and as per Engineer In-charge. It includes etching and engraving in 2mm thick SS plate for lettering, symbols, signs etc. fixed with SS 304 grade studs, SS 304 grade screws, nut-bolts, adhesives, etc. for fixing complete as per design & drawings.

6

64620

10770

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 900 mm equilateral triangle retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

2

11092

5546.17

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 600 mm equilateral triangle retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

20

98185

4909.26

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 600 mm circular retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

20

106521

5326.07

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 800 mm x 600 mm rectangular retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

5

29862

5972.56

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 600 mm x 450 mm rectangular retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

20

105670

5283.54

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 600 mm x 600 mm square retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

20

111561

5578.07

... More
Retro-Reflectorised Traffic Signs supported on GI pipe 50 mm dia: Providing and fixing of 900 mm sides octagon retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of enscapulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on GI Pipe 50 mm dia. firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701.

3

19809

6603.09

... More
3M Vinyl Sign Boards: Providing and fixing plotted cutouts/ printed 3M vinyl sticker cutouts for lettering, symbols, signs etc. in required size and shape with night vision effects, stick (external grade adhesives) on ACP sheet as per drawing and as per direction of Engineer In-charge. (ACP sheet shall be paid in separate item.)

10

32200

3220

... More
Construction of Drain Trench of Flamed finish Granite stone in required size, design, colour and patterns of 30 mm thick of size having cross sectional area 150mm x 150mm, bottom Flamed finish Granite of 210mm and Top Flamed finish Granite cover of 210mm with perforation/ hole of 30mm @ 300 c/c including excavation, backfilling, watering, soling, compaction, PCC at bottom, one side masonry etc. complete. It includes 12 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Coarse sand), portions butt jointed or with 5mm gap, jointing in 1:2 (cement : fine sand) and pointing full depth (flushed) or struck pointed as per drawing with white cement slurry admixed with pigment of matching shade including rubbing, pointing, curing, polishing, moulding/ champhering at edges and final scrubbing using mechanical/ manual means to achieve clean surface etc. having 100mm thick PCC in M-15 at bottom level and one side brick masonry of 450mm all complete as specified and as directed by the Engineer In-charge. Mockup must be approved from the Architect prior to start the work at site. It shall be completed with all respect in true line level, plumb with neat & clean surface up to the level of satisfaction of Engineer In-charge.

2345

14428785

6153

... More
Providing and fixing 6mm thick mirror on 6mm thick waterproof ply backing fixed with SS 316 grade studs, anchor fasteners, fittings and accessories i.e. SS screws as per direction of Engineer In-charge.

53.87

184450

3424

... More
Providing and fixing 18 mm thick, 150 mm wide Pelmet of flat pressed three layer or graded plain wood particle board medium density grade I, ISI marked and conforming to IS:3087 marked, including top cover of 6 mm waterproof ply wood conforming to IS: 710 BWP grade, fixed with nickel plated brackets, necessary supports, anchor fastners, hangers if required, other fittings and accessories etc. complete as per direction of Engineer In-charge.

4034.4

1595798

395.55

... More
Supplying, Erecting, Testing and Commissioning of machine room less Passenger Elevator/ Lift of 884 kg load/ 13 person capacity in SS satin/ matt finish with rated speed of 1m/s as per specifications of Schindler, Thyssenkrupp, Otis, Kone or equivalent make as approved by the Architect and Engineer In-charge. (Basement + Ground + 2 Storey - 4 Nos of Stops)

12

19139198

1594933.21

... More
Supplying, Erecting, Testing and Commissioning of machine room less Passenger Elevator/ Lift of 884 kg load/ 13 person capacity in SS satin/ matt finish with rated speed of 1m/s as per specifications of Schindler, Thyssenkrupp, Otis, Kone or equivalent make as approved by the Architect and Engineer In-charge. (Ground + 2 Storey - 3 Nos of Stops)

4

6256000

1564000

... More
Providing and fixing in 100 mm thick SIL FLEX (Capcell HD 100) expansion joint filler board in sheet foam of best quality and approved make including cutting to required size and shape at all levels etc. complete as directed.

151.91

529248

3483.99

... More
Providing and filling the expansion joint by polymer base Polyurethane Sealant confirm to BS 4254-1983 as per required shade and specification by making groove of 100 mm x 25mm by cutting groove and removing mortar drop or any other foreign materials including applying primer and filling required size of joint PU foam etc. complete as directed by Engineer In-charge.

807.15

296184

366.95

... More
Providing and fixing of expansion joint system related with floor joint 100mm-150 mm gap location as per drawings and direction of Engineer ln-charge. The joint system will be of extruded aluminium base members, self-aligning/ self-centering arrangement and support plates etc. as per ASTM 8221-02. The system shall be such that it provides floor to floor/ floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to its components. The system shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufacturer's design and as approved by Engineer Incharge. (Material shall confirm to ASTM 6063.)

272.83

1998776

7326.14

... More
Providing and fixing of expansion joint system related with wall joint of 100mm-150 mm gap (internal/ external) location as per drawings and direction of Engineer ln-charge. The joints shall be of extruded aluminium base members, self-aligning/ centering arrangement and support plates as per ASTM 8221-02. The material shall be such that it provides an expansion joint system suitable for vertical wall to wall/ wall to corner application to both new and existing construction in Buildings with no slipping down tendency amongst the components of the joint system. The joint system shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multi-cellular to facilitate movement. (Material shall confirm to ASTM 6063.)

141.45

794883

5619.54

... More
Providing and fixing expansion joint system of approved make and manufacturer for various roof joint of 100mm-150 mm gap locations as per approved drawings and direction of Engineer In-charge. The joints shall be of extruded aluminium base members with, self-aligning and self-centering arrangement support plates as per ASTM 8221ro2. The system shall be such that it provides watertight roof to roof/ roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. The system shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer's pre engineered selfcentering arrangement that freely rotates/ moves in all directions, The self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The joint system shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.)

392.87

2410339

6135.24

... More
Precast Exposed Concrete Bench: Providing and fixing precast exposed concrete bench of size 1800(L) x 600(B) x 480(H)mm with WPC top and side covered as per design and selection by Architect. The bench support to be 30mm embedded in PCC and 450mm to be maintained above floor finished level with necessary support system, fittings and accessories, etc. as per details provided by manufacturer. It includes minimum 1 mockups for approval complete as per instruction of Engineer In-charge.

293

6023655

20558.55

... More
Sweet Soil: Providing, supplying, stacking, mixing, filling, spreading, grading, cleaning & removal of stone, gravel, plants & roots, branches, etc. at sub-base level including spraying of anti-termite chemical as per manufacturer specifications at bottom and sides of pits, trenches, engineered soil etc. complete with watering. soil consisting of selected soil or murrum or agricultural soil brought from outside including compensation for good soil/ agricultural soil, selected graded river sand and organic manure should be well rotten of standard quality, in proportion of 60%, 20% & 20% respectively. The contractor shall follow workmanship and do supervision under qualified horticulture having 10 years experience. It allows for uproot, polwing, weeding etc. for at least 12 (twelve) months of after final plantation including watering.

1324.9

1885634

1423.23

... More
Providing and fixing wooden rounded hand rail of teak wood/ sissu wood in required length and size of 75mm dia. with making groove, surface cleaning, 2 or 3 coats of polishing/ varnishing etc. fixed in tongue and groove joint system on M.S. railling as per drawing and as directed by Engineer In-charge.

620.2

805193

1298.28

... More
Providing and fixing wooden moulded hand rail of teak wood/ sissu wood in required length and size of 100 x 60 mm with making groove, surface cleaning, 2 or 3 coats of polishing/ varnishing etc. fixed in tongue and groove joint system on M.S. railling as per drawing and as directed by Engineer In-charge.

2055.9

3998273

1944.78

... More
Metal Beam Crash Barrier Type "W": Providing and erecting "W" metal beam crash barrier comprising of 3mm thick corrugated sheet metal beam rail, 70 cm above road/ ground level, fixed on ISMC series channel vertical post, 150 mm x 75 mm x 5 mm spaced 2m centre to centre, 1.8 m high, 1.1 m below ground/ road levels, all steel parts and fitments to be galvanized by 80 micron hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 mm x 75 mm x 5 mm, 330 mm long complete as per Clause 810 of MoRTH specifications.

200

1002266

5011.33

... More
Providing and fixing in position pre-cast R.C.C. manhole circular shape 560 mm internal diamcter cover and frame of required shape and approved quality of EHD-35.

1

2055

2055.36

... More
Painting Lines, Dashes, Arrows, etc. on road in 2 (two) coats with ready mixed road marking paint confirming to IS:164 on bituminous/ concrete surface in required width, size and shape, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and technical specification of MoRTH clause 1702.

14

4674

333.88

... More
Supply & installing a Fish Sculpture of dimensions 4.2m(L) x 1.2m(w) x 2.5m(H) made from hand carved Khatu Stone weighing approximately 3-4 tonnes, with a river wash finish and applied with anti-weathering coat, including transportation, loading, unloading, placing etc. cost from the source of casting to the site without breaking of edges & erection in line, level, gradient and plumb with necessary testing, setting in position, labour charges for installation with all the necessary required machineries and accessories. The sculpture will be erected using required base plates with necessary bolting/ riveting on RCC pedestal of M25 grade as per shop drawing and material matrix as per specifications, after getting it approved from Architect.

1

1389226

1389226.39

... More
Supply & installing a Hollow Fish Scultpure of dimensions 3.0m(L) x 2.0 (H) fabricated from 2-3mm M.S. Sheet with anti weathering rusted finish, including transportation, loading, unloading, placing etc. cost from the source of fabricating to the specific location at site without breaking of edges & erection in line, level, gradient and plumb with necessary testing, setting in position, labour charges for installation with all the necessary required machineries and accessories. The sculpture will be erected using required base plates with necessary bolting/ riveting on RCC pedestal of M25 grade as per shop drawing and material matrix as per specifications, after getting it approved from Architect.

1

555729

555729.55

... More
Supply & installing a Make in India Lion Symbol Scultpure of dimensions 4.2 m(L) x 2.5 (H) x 1.2 (D) fabricated from M.S. Sheet with anti weathering rusted finish, including transportation, loading, unloading, placing etc. cost from the source of fabricating to the specific location at site without breaking of edges & erection in line, level, gradient and plumb with necessary testing, setting in position, labour charges for installation with all the necessary required machineries and accessories. The sculpture will be erected using required base plates with necessary bolting/ riveting on RCC pedestal of M25 grade as per shop drawing and material matrix as per specifications, after getting it approved from Architect.

1

1583999

1583999.7

... More
Supply & installing a Wing Scultpure of dimensions 3.0 m(L) x 2.0 (H) fabricated from M.S. Sheet with anti weathering rusted finish, including transportation, loading, unloading, placing etc. cost from the source of fabricating to the specific location at site without breaking of edges & erection in line, level, gradient and plumb with necessary testing, setting in position, labour charges for installation with all the necessary required machineries and accessories. The sculpture will be erected using required base plates with necessary bolting/ riveting on RCC pedestal of M25 grade as per shop drawing and material matrix as per specifications, after getting it approved from Architect.

1

589993

589993.8

... More
Providing and fixing 1500mm height x 6000mm width of 'KHUBLEI' Waterproof Embossed Acrylic letters of 3 inch thick with required aluminium back plate/ sheet, LED lights with required accessories. The rate shall include material, necessary aluminium fabrication from the support, labour and installation cost all complete and as directed by Engineer In-charge. The total board will be erected using required base plates with necessary bolting/ riveting on RCC pedestal of M25 grade as per shop drawing and material matrix as per specifications, after getting it approved from Architect.

1

94461

94461

... More
Supply, installation, testing & commissioning single girder type fully electrically operated 3T EOT crane for 12m span, 12m long travel with electrically operated hoist, class II duty, geared travelling trolley with ten (10) meter lift complete with long travel rail track (40 mm sq. bar), moving or cross girder, all three motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cables form motor to starter panel & other required accessories & tested as per IS Specifications and directed by Engineer In-charge.

2

1274775

637387.5

... More
Landscape Work

-

-

-

... More
Supplying of good earth: Providing well draining good earth including transport, spreading and mixing etc. all complete as per direction of Engineer-in-charge, the soil should be fine in texture, free from stones, gravels, plant roots and weeds.Supplying of organic manure: Organic manure should be well rotten and of standard quality (Preferably Dynamic lifter). The supply of the manure shall be in 50kg bags including transportation upto site & internal transportation at desired locations. Supplying of sand: Providing fine textured local sand including transport, spreading and mixing etc. all complete as per direction of Engineer-in-charge. Supplying and executing anti termite treatment with chloropyriphos chemical , drenching the Planting area at 10lts/sm.( Mixing Ratio of 3ml/litre)

8486.41

4419350

520.76

... More
TREES: Supplying and planting of shade, ornamental, fruit, flowering trees, small, medium and large specimens suitable for Karimnagar region, adaptable to low water, as per under noted varieties, with ht. as specified in drawings including excavation of pit of size 0.75 m x 0.9 m x 0.9 m filling the pit with soil mixture etc. as per specifications and as directed complete in all respect including watering and nurturing the trees. The trees may be planted individually in rows or in cluster as per direction in drg. and all plant material and its sizes and height/girth and crown should be shown to the landscape architect/ Project Manager & written approval to be sought before planting. (Cost excluding soil mix). Trunk Diameter to be measured 300 mm above Polybag. T-1, Jacaranda mimosifolia; Height min 3000 mm, Trunk Diameter min. 75 mm

236

417130

1767.5

... More
T-2, Cinnamomum tamala; Height min 3000 mm, Trunk Diameter min. 75 mm

13

23634

1818

... More
T-3, Grevillea robusta; Height min 3000 mm, Trunk Diameter min. 75 mm

30

75750

2525

... More
T-4, Wallichia oblongifolia; Height min 3000 mm, Trunk Diameter min. 75 mm

36

59994

1666.5

... More
T-5, Ficus benghalensis; Height min 3000 mm, Trunk Diameter min. 75 mm

97

244925

2525

... More
T-6, Lagerstroemia indica; Height min 3000 mm, Trunk Diameter min. 75 mm

44

111100

2525

... More
T-7, Prunus serrulata; Height min 3000 mm, Trunk Diameter min. 75 mm

30

56055

1868.5

... More
T-8, Betula alnoides; Height min 3000 mm, Trunk Diameter min. 75 mm

67

118422

1767.5

... More
T-9, Magnolia grandiflora; Height min 3000 mm, Trunk Diameter min. 75 mm

139

231643

1666.5

... More
T-10, Pinus kesiya; Height min 3000 mm, Trunk Diameter min. 75 mm

45

72720

1616

... More
T-11, Photinia integrifolia; Height min 3000 mm, Trunk Diameter min. 75 mm

44

111100

2525

... More
T-12, Gingko biloba ; Height min 3000 mm, Trunk Diameter min. 75 mm

23

58075

2525

... More
SHRUBS: Providing, planting and developing plants/ flower bed with under noted varieties of plants (both shade & sun loving), including excavating the soil to a depth of 450mm - 600mm of required area as per plant species, removal of excavated earth to directed location, filling the excavated bed with approved soil mixture, planting the approved variety plants, providing strong stack etc. as per specification and as directed complete in all respect, including watering and nurturing the plants. Height & spread to be measured above polybag top. S-1, Rhododendron arboretum; Height min 1000mm, spread min 1000mm

2510.3

507081

202

... More
S-2, Rubus fruticosus; Height min 600mm, spread min 600mm

509.22

102862

202

... More
S-3, Osbeckia crinita; Height min 450 mm, spread min 1000mm

21445.37

4331965

202

... More
S-4, Mahonia pycnophylla Height min450mm, spread min 450mm

3016.39

670242

222.2

... More
S-5, Daphne papyraceae; Height min 600mm, full of branches and foliage spread min 600mm

5509.33

1391105

252.5

... More
S-6, Polygala arillata,; Height min 1000mm, spread min 500mm

1281.84

155359

121.2

... More
S-7, Camellia caduca; Height min 600mm, full of branches and foliage spread min 450mm

402.3

121896

303

... More
S-8, Hibiscus rosa-sinensis; Height min 1000mm, spread min 500mm

1693.4

136826

80.8

... More
S-9, Bougainvilla; Height min 600mm, full of branches and foliage spread min 450mm

424.7

51473

121.2

... More
S-10, Cycas sp; Height min 1000mm, spread min 1000mm

17.71

5366

303

... More
S-11, Strelitzia reginae; Height min 450mm, spread min 1000mm

704.48

56921

80.8

... More
GROUND COVER: Providing, planting and developing ground covers with the approved variety of plants including excavating the existing soil to a maximum depth of about 300 mm, removal of excavated earth to directed location, dressing the soil in proper slopes, filling excavated bed with approved soil mixture, planting approved quality grass, including weeding out and removal of foreign matter, watering etc complete. Height & spread to be measured above polybag top. GC-1, Dracaena elliptica; Height min 300mm, spread min 150mm

29955.84

1210215

40.4

... More
GC-2, Leea edgeworthia; Carpet Effect

16392.11

2483404

151.5

... More
GC-3, Phlogacanthus sp."; Carpet Effect

4407.83

890382

202

... More
GC-4, Herbaceous perennial; Height min 450mm, spread min 150mm

4757.96

576665

121.2

... More
GRASSES: Providing, planting and developing grasses with the approved variety of plants including excavating the existing soil to a maximum depth of about 500 mm, removal of excavated earth to directed location, dressing the soil in proper slopes, filling excavated bed with approved soil mixture, planting approved quality grass, including weeding out and removal of foreign matter, watering etc complete. Height & spread to be measured above polybag top. GS-1, Paspalum; Height min 300mm, spread min 150mm

3180.96

642552

202

... More
GS-2, Imperata ; Carpet Effect

783.84

95001

121.2

... More
GS-3, Saccharum; Carpet Effect

1721.6

139105

80.8

... More
GS-4, Cyperaceae: Height min 450mm, spread min 150mm

3171.02

640545

202

... More
LAWN: Providing, planting and developing grasses with the approved variety of plants including excavating the existing soil to a maximum depth of about 500 mm, removal of excavated earth to directed location, dressing the soil in proper slopes, filling excavated bed with approved soil mixture, planting approved quality grass, including weeding out and removal of foreign matter, watering etc complete. Height & spread to be measured above polybag top. LW-1, Stenotarhrum Secundatum; Carpet Effect

300

45450

151.5

... More
LW-2, Cynodon dactylon; Carpet Effect

300

45450

151.5

... More
CLIMBER: Providing, planting and developing creeper plants with the approved variety of plants including excavating the existing soil to a maximum depth of about 500 mm, removal of excavated earth to directed location, dressing the soil in proper slopes, filling excavated bed with approved soil mixture, planting approved quality grass, including weeding out and removal of foreign matter, watering etc complete. Height & spread to be measured above polybag top. CR-1, Ficus pumila; As mentioned in drawing

15

1818

121.2

... More
CR-2, Rhapidophora decursivia .; As mentioned in drawing

25

3787

151.5

... More
ELECTRICAL & ELV

-

-

-

... More
UNITISED SUBSTATION EQUIPMENT: Supplying, installation, testing and commissioning loading., unloading at site, shifting to site of 11 KV, 21 KA for 1 sec. unitized / Compact sub-station consiting of following 11 KV SF6 insulated compact switch gear with VCB, transformer & manually load break switches in a pre -fabricated dust and vermin proof out door enclosure having modular construction of galvanised sheet steel dully painted with epoxy based powder paint ( Colour RAL 7032) . The enclosure shall have IP54 degree of protection for HT& LT switch gear compartment and IP23 degree of protection for transformer compartment. Short Circuit breaking capacity of 21 KA at 11 KV 3 phase. Interconnection between HT switch gear and transformer using suitable size aluminium conductor armoured XLPE single core cable, HV Danger Notice board, Internal earth connections copper bus bars of 25mm X 6mm, The complete unit shall be installed on a sub station plinth( Base).Scope also includes necessory RCC foundation and required all kind of accessories for installing CSS.

1

3972753

3972753.2

... More
USS-1 A) 11 KV RING MAIN UNIT Indoor floor-standing type, metal-clad, totaly enclosed 11 KV RING MAIN UNIT with SF6 medium suitable for operation on 3 phase, 50 Hz, Earthed system and having a Short Circuit breaking capacity of 21 KA at 11 KV and comprising of the following: i) Isolators (Loop-in & Loop out) Manually operated 630 Amp(Continuous rating) load break isolator modbus compatible with built in earth switch having full making capacity, Mechanical position indicator ( Switch on/ off/ earthed), live cable indication, cable compartment cover interlocked with earth switch, cable termination bushings suitable for 3 no. 1CX300 sq.mm. XLPE cable( cable entry from bottom ), cable termination boots ( Push on type), suitable for use on 11kV, 3 Phase, 50 Hz, AC supply with short circuit breaking current of 21 kA at 11 KV as per detailed specifications complete as required. 2 Nos ( 1 No. for incoming Feeders and 1 No for outgoing Feeders) ii) Outgoing for Transformer protection 1 No. modbus compatible Fixed motorised operated 630 Amp vaccum circuit breaker in SF6 insulated stainless steel enclosure along with motorised spring charging arrangment and manual close and open push button, ON/OFF indication, self powered S/C, O/C & E/F relay With RS-485 communication port and single protection core cast resin type CT ( 1.2 VA, CL-5P10), motorized operated 630 Amp load breaker swith with built in earth switch having full making capacity, Mechanical position indicator ( Switch on/ off/ earthed), live cable indication, cable compartment cover interlocked with earth switch, cable termination bushings suitable for 3 no. 1CX300 sq.mm. XLPE cable( cable entry from bottom ), cable termination boots ( Push on type), suitable for use on 11kV, 3 Phase, 50 Hz, AC supply with short circuit breaking current of 21 kA at 11 KV as per detailed specifications complete as required.

-

-

-

... More
B) Transformer Supplying, installation, testing and commissioning of Oil type 500 kVA, 11KV / 415Volts , 3 phase, 50 Hz, Dyn11 vector group, copper wound, class "F" insulation associated with winding temperature indicator / controller actuated by means of resistance temperature detector embedded in LV windings , indoor type distribution Transformer with approximately 5 % impedance, tappings for on load operation on HV side in steps of +/- 2.5 %, + 10 % & - 10 % having cable end boxes on HV side suitable for 3 X 240 sq mm XLPE Cable of 11 KV grade and 3X3.5CX300 sqmm.MV cable on LV side with neutral brought out separately including supplying and laying copper conductor multicore control cable from transformer to HT breaker for safety tripping, suitably mounted on MS channel with all accessories and confirming to IS 11171:1985 complete with all fittings and accessories as per specifications attached etc. as required at site C) LT Switchgear 1 No. 800A FP, 50 kA Fault breaking capacity ( Icu = Ics =Icw 100% up to 433 V ), ACB with microprocessor release (EMI & EMC Certified) for O/L, S/C, E/F protection & with RS-485 port for communication.

-

-

-

... More
USS-2 A) For Transformer protection 1 No. modbus compatible Fixed motorised operated 630 Amp vaccum circuit breaker in SF6 insulated stainless steel enclosure along with motorised spring charging arrangment and manual close and open push button, ON/OFF indication, self powered S/C, O/C & E/F relay With RS-485 communication port and single protection core cast resin type CT ( 1.2 VA, CL-5P10), motorized operated 630 Amp load breaker swith with built in earth switch having full making capacity, Mechanical position indicator ( Switch on/ off/ earthed), live cable indication, cable compartment cover interlocked with earth switch, cable termination bushings suitable for 3 no. 1CX300 sq.mm. XLPE cable( cable entry from bottom ), cable termination boots ( Push on type), suitable for use on 11kV, 3 Phase, 50 Hz, AC supply with short circuit breaking current of 21 kA at 11 KV as per detailed specifications complete as required. B) Transformer Supplying, installation, testing and commissioning of Oil type 500 kVA, 11KV / 415Volts , 3 phase, 50 Hz, Dyn11 vector group, copper wound, class "F" insulation associated with winding temperature indicator / controller actuated by means of resistance temperature detector embedded in LV windings , indoor type distribution Transformer with approximately 5 % impedance, tappings for on load operation on HV side in steps of +/- 2.5 %, + 10 % & - 10 % having cable end boxes on HV side suitable for 3 X 240 sq mm XLPE Cable of 11 KV grade and 3X3.5CX300 sqmm.MV cable on LV side with neutral brought out separately including supplying and laying copper conductor multicore control cable from transformer to HT breaker for safety tripping, suitably mounted on MS channel with all accessories and confirming to IS 11171:1985 complete with all fittings and accessories as per specifications attached etc. as required at site. C) LT Switchgear 1 No. 800A FP, 50 kA Fault breaking capacity ( Icu = Ics =Icw 100% up to 433 V ), ACB with microprocessor release (EMI & EMC Certified) for O/L, S/C, E/F protection & with RS-485 port for communication.

1

3873963

3873963.6

... More
SUBSTATION & AUXILIARY INSTALLATION

-

-

-

... More
Providing and fixing danger plates made of mild steel at least 2 mm thick and vitreous enamelled white on both sides & with inscriptions in signal red colour on front side as required.

-

-

-

... More
High Voltage - size 250 mm X 200 mm

2

620

310.48

... More
Medium Voltage - size 200 mm X 150 mm

6

1716

286.03

... More
Providing and fixing carbon dioxide( CO2) type fire extinguishers confirming to IS 2878 - 1976 and cylinders fully charged of 4.5 KG capacity as required.

4

73376

18344.05

... More
Supplying and fixing Foam fire extinguishers, portable type 9 litre capacity hanged on wall with bracket complete as required.

4

33676

8419.21

... More
SITC of printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.

4

600

150

... More
SITC of pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.

4

1000

250

... More
SITC of rubber matting of 3 mm thickness as per IS 15652 and IEC 61111. (A) 3 mm

5

4500

900

... More
SITC of stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, ScisR&BR&BSORs, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)

4

1400

350

... More
SITC of FIREbucket round bottom of9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside andRed out side with FIRE mark,filled with dry-sand and kept on existing stand provided or hung on wall hook.

8

2000

250

... More
SITC of floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, 900 mmheight frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint.

2

2200

1100

... More
Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms.

8

560

70

... More
SITC of 11 KV, 3 core Al. 240 sqmm H.T. XLPE armoured unearth cable

385

1314390

3414

... More
SITC of H.T. cable outdoor type end connection for 11 KV XLPE, 240 sq mm x 3 core cable

4

26765

6691.35

... More
SITC of H.T. cable indoor type end connection for 11 KV XLPE, 240 sq mm x 3 core cable

4

15094

3773.65

... More
LT PANEL

-

-

-

... More
Supply, installation, testing and commissioning of 3 phase 415V 4 wire Free Standing Floor mounted MV panel made out of minimum 14 SWG CRCA sheet after seventank process and painting with Epoxy powder coating including all switchgear as detailed below. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The panel shall consist of suitable rating FP/TPN Aluminium- busbar-as per SLD (at the rating of 0.8ASq.mm) supported with DMC/ SMC barriers and colour coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity as given in SLD and consist of the switchgear as mentioned below. The panel shall be mounted on plinth, stand, etc. including all materials. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. All the Panels shall have minimum 25% outgoing as per SLD. The earth bus shall be continuoulsy run without any jointing/welding and its Size should be per SLD. The size of all Panel Mounting Meters shall be 96X96mm.The Panels shall be mounted on U channels including supply and fixing of the same. MCBs shall be provided for Control purposes. (All Panels shall be extendable type only). Price shall be inclusive following: Shifting of panels from site store to the suitable location. Installation of panel as located in electrical drawings or as per site conditions, including removing packing etc. Earthing all components, frame etc. to a common internal earth bar. Connection, testing & commissioning. Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in copy to the consultant or engineer-in-charge. Supply, installation, testing and commissioning all accessories, supporting structure, hard ware etc to complete the job. Supply, installation, testing and commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc. The rates for the distribution boards apart from the Breakers and instruments shall also include the following:

-

-

-

... More
This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings. Supporting rigid steel framework. Cubicle type, 14 gauge CRCA sheet steel enclosed. Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. All MCB’s shall be of minimum 10 KA breaking capacity. The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocesR&B R&B SOR based for 250 amps and above capacity, unless specified otherwise. All motor feeders MCCBs shall be of motor duty. Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 4x for all Indoor panel. IP 65 and double door for all outdoor panel. All MCCB’s shall be provided with operating mechanism for door interlock. All measuring instruments (Meters) shall be of digital electronic with LED of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors.All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.

-

-

-

... More
SITC of MAIN LT PANEL of Block A& B ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

235824

235824.89

... More
SITC of BLOCK A METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

243869

243869.18

... More
SITC of BLOCK B METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

279010

279010.06

... More
SITC of BLOCK A COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

90745

90745.3

... More
SITC of BLOCK B COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

103023

103023.44

... More
SITC of BLOCK A&B COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

59838

59838.27

... More
SITC of BLOCK A & B FAÇADE PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

58285

58285.86

... More
SITC of BLOCK A & B EV CHARGING PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

48689

48689.16

... More
SITC of MAIN LT PANEL of Block C&D ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

194333

194333.26

... More
SITC of BLOCK C METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

144091

144091.69

... More
SITC of BLOCK D METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

146631

146631.99

... More
SITC of BLOCK C COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

78043

78043.78

... More
SITC of BLOCK D COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

78043

78043.78

... More
SITC of BLOCK C&D COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

5983

5983.83

... More
SITC of BLOCK C & D FAÇADE PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

58285

58285.86

... More
SITC of BLOCK C & D EV CHARGING PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

48689

48689.16

... More
SITC of MAIN LT PANEL of Block E ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

136894

136894.16

... More
SITC of BLOCK E METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

153547

153547.26

... More
SITC of BLOCK E COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

68023

68023.7

... More
SITC of BLOCK E FAÇADE PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

58285

58285.86

... More
SITC of MAIN LT PANEL of Block G ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

171611

171611.65

... More
SITC of BLOCK G METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

154817

154817.42

... More
SITC of BLOCK G COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

82136

82136.5

... More
SITC of BLOCK G FAÇADE PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

58285

58285.86

... More
SITC of BLOCK G EV CHARGING PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

48689

48689.16

... More
SITC of MAIN LT PANEL of Block H ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

173164

173164.06

... More
SITC of BLOCK H METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

159192

159192.38

... More
SITC of BLOCK H COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

82136

82136.5

... More
SITC of BLOCK H FAÇADE PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

58285

58285.86

... More
SITC of BLOCK H EV CHARGING PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

48689

48689.16

... More
SITC of MAIN LT PANEL of Block I ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

148607

148607.78

... More
SITC of BLOCK I METER PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

151994

151994.86

... More
SITC of BLOCK I COMMON DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

82136

82136.5

... More
SITC of BLOCK I FAÇADE PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

58285

58285.86

... More
SITC of BLOCK I EV CHARGING PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

48689

48689.16

... More
SITC of MAIN LT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

999891

999891.88

... More
SITC of DG SYNCH PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

846203

846203.49

... More
SITC of APFCR PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

665418

665418.52

... More
SITC of COMMON 'EXTERNAL DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

118829

118829.78

... More
SITC of EXTERNAL LIGHTING PANEL-1 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

62801

62801.96

... More
SITC of EXTERNAL LIGHTING PANEL-2 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

62801

62801.96

... More
SITC of PLUMBING PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (INDOOR)

1

59697

59697.14

... More
SITC of EV CHARGING PANEL-1 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

80019

80019.58

... More
SITC of EV CHARGING PANEL-2 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

80019

80019.58

... More
SITC of MAIN LT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

1000597

1000597.52

... More
SITC of DG SYNCH PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

846203

846203.49

... More
SITC of APFCR PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

182170

182170.69

... More
SITC of COMMON EXTERNAL DEVELOPMENT PANEL ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Indoor)

1

105846

105846

... More
SITC of EXTERNAL LIGHTING PANEL-1 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

62801

62801.96

... More
SITC of EXTERNAL LIGHTING PANEL-2 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

62801

62801.96

... More
SITC of EV CHARGING PANEL-1 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

61108

61108.42

... More
SITC of EV CHARGING PANEL-2 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT. (Outdoor)

1

61108

61108.42

... More
DISTRIBUTION BOARDS

-

-

-

... More
Supply, installation, testing and commissioning of Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for SPN DB 8 Way + 8 Module

28

74371

2656.12

... More
SPN DB 12 Way + 12 Module

13

41233

3171.82

... More
VTPN DB 4 Way 8+12 Module

57

723054

12685.17

... More
VTPN DB 6 Way 8+18 Module

9

125525

13947.31

... More
VTPN DB 8 Way 8+24 Module

1

16111

16111.12

... More
VTPN DB 12 Way 8+36 Module

1

21856

21856.13

... More
TPN DB 4 Way 8+12 Module

53

272701

5145.31

... More
TPN DB 6 Way 8+18 Module

14

88572

6326.64

... More
Supplying & fixing of Load Kontaket Miniature Circuit Breaken (RX3 MCBs)

-

-

-

... More
6-32 Amp SP MCB

1069

373963

349.83

... More
6-32 Amp TP MCB

162

249596

1540.72

... More
40 Amp TP MCB

12

54764

4563.68

... More
6-32 Amp FP MCB

128

261724

2044.73

... More
50-63 Amp FP MCB

16

45117

2819.87

... More
6-32 Amp DP MCB

227

218197

961.22

... More
Supplying fitting and fixing of (RCCBs) of the following Amp capacity

-

-

-

... More
25 Amp DP RCCB 30mA

214

727465

3399.37

... More
40 Amp DP RCCB 30mA

20

79917

3995.88

... More
40 Amp FP RCCB 30mA

12

57609

4800.8

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

162

46336

286.03

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 25/32A DP MCB with Enclouser

33

41018

1243

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 40A DP MCB with Enclouser

9

8108

900.96

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 63A DP MCB with Enclouser

1

137

137.44

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 40A FP MCB with Enclouser

9

5745

638.4

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 63A FP MCB with Enclouser

1

763

763.53

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 80A FP MCB with Enclouser

1

99

99.59

... More
Supply ,fixing, connection and testing of MCCBs with enclouser and all accessories to complete the job. 100A FP MCCB with Enclouser

1

663

663.94

... More
LT CABLES & TERMINATION Supplying, Laying, Testing & Comissioning of PVC/ XLPE armoured cables with Aluminium/ Copper conductor 1100V, Grade of following sizes along wall etc. in ground including the cost of digging of trenches sand, cushioning besides laying etc & refilling the same in layers or by supporting them on wall and all other accessories as required

-

-

-

... More
Aluminium Cable:25 sq. mm 3.5 Core Cable

15

9888

659.25

... More
Aluminium Cable:35 sq. mm 3.5 Core Cable

606

375661

619.9

... More
Aluminium Cable:50 sq. mm 3.5 Core Cable

85

68869

810.24

... More
Aluminium Cable:70 sq. mm 3.5 Core Cable

80

77238

965.48

... More
Aluminium Cable:95 sq. mm 3.5 Core Cable

15

16284

1085.63

... More
Aluminium Cable:120 sq. mm 3.5 Core Cable

60

75728

1262.14

... More
Aluminium Cable:150 sq. mm 3.5 Core Cable

520

740354

1423.76

... More
Aluminium Cable:185 sq. mm 3.5 Core Cable

1682

2831149

1683.2

... More
Aluminium Cable:240 sq. mm 3.5 Core Cable

80

161536

2019.21

... More
Aluminium Cable:300 sq. mm 3.5 Core Cable

45

107515

2389.24

... More
Aluminium Cable:25 sq. mm 4 Core Cable

125

85196

681.58

... More
Supplying, Laying, Testing & Comissioning of PVC/ XLPE armoured cables with Aluminium/ Copper conductor 1100V, Grade of following sizes along wall etc. in ground including the cost of digging of trenches sand, cushioning besides laying etc & refilling the same in layers or by supporting them on wall and all other accessories as required

-

-

-

... More
Copper Cable:2.5 Sq.mm 4 Core cable

250

160026

640.11

... More
Copper Cable:4 Sq.mm 4 Core cable

1315

957794

728.36

... More
Copper Cable:6 Sq.mm 4 Core cable

870

752082

864.46

... More
Copper Cable:10 Sq.mm 4 Core cable

640

713176

1114.34

... More
Copper Cable:16 Sq.mm 4 Core cable

660

922838

1398.24

... More
Copper Cable:16 Sq.mm 3 Core cable

15

17560

1170.69

... More
Copper Cable:10 Sq.mm 3 Core cable

120

116112

967.6

... More
Copper Cable:6 Sq.mm 3 Core cable

15

11435

762.39

... More
Copper Cable:4 Sq.mm 3 Core cable

510

336215

659.25

... More
Providing, supplying of Multicore cables including carriage testing of the following sizes PVC insulated and FR PVC round Sheathed, Copper conductor flexible cable 1100Volt confirming to IS694

-

-

-

... More
4 sq. mm 3 Core Cable

100

39129

391.29

... More
6 sq. mm 3 Core Cable

100

49230

492.31

... More
CABLE TERMINATION:supplying and making end termination with brass compression grand and aluminium lugs for following size of PVC insulated and PVC streathed / XLPE aluminium co{ductor cable of 1.1 KV grade as required

-

-

-

... More
25 sq. mm 3.5 Core Cable

2

531

265.83

... More
35 sq. mm 3.5 Core Cable

22

7017

318.99

... More
50 sq. mm 3.5 Core Cable

2

699

349.83

... More
70 sq. mm 3.5 Core Cable

4

1565

391.29

... More
95 sq. mm 3.5 Core Cable

2

1005

502.94

... More
120 sq. mm 3.5 Core Cable

10

5199

519.95

... More
150 sq. mm 3.5 Core Cable

4

2360

590.13

... More
185 sq. mm 3.5 Core Cable

30

22393

746.44

... More
240 sq. mm 3.5 Core Cable

10

8602

860.21

... More
300 sq. mm 3.5 Core Cable

6

5971

995.25

... More
25 sq. mm 4 Core Cable

2

531

265.83

... More
CABLE TERMINATION:Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

-

-

-

... More
3/4 X 2.5 sq. mm (15mm)

50

20251

405.04

... More
3/4 X 4 sq. mm (17mm)

268

123300

460.08

... More
3/4 X 6 sq. mm (19mm)

58

31022

534.88

... More
3/4 X 10 sq. mm (22mm)

52

32657

628.02

... More
3/4 X 16 sq. mm (28mm)

14

12151

867.94

... More
Concealed wiring in looping in system with 2x1.5 sqmm PVC insulated single core cable of 600V grade in heavy gauge PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets fan regulator, bell push etc complete to light point.

823

1567296

1904.37

... More
Concealed wiring in looping in system with 2x1.5 sqmm PVC insulated single core cable of 600V grade in heavy gauge PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets fan regulator, bell push etc complete to Light Plug Point when fixed elsewhere with continous earth wire.

1765

3227966

1828.88

... More
Concealed wiring in looping in system with 2x1.5 sqmm PVC insulated single core cable of 600V grade in heavy gauge PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets fan regulator, bell push etc complete for Two way switching wiring.

124

325403

2624.22

... More
Loop light point controlled by same switch or SP MCB

377

438545

1163.25

... More
Wiring in looping in system with 1.5 sqmm PVC wire in heavy gauge 16SWG 3/4 inch dia MS conduit pipe Including supplying and fitting of bends, tees, joints Boxes etc as necessary complete with 5amp FT switch ceiling rose etc including earthing the conduit to light point.

72

183278

2545.54

... More
Wiring in looping in system with 1.5 sqmm PVC wire in heavy gauge 16SWG 3/4 inch dia MS conduit pipe Including supplying and fitting of bends, tees, joints Boxes etc as necessary complete with 5amp FT switch ceiling rose etc including earthing the conduit complete to Light Plug Point when fixed elsewhere

176

515198

2927.27

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, onnection, painting etc. as required.

356

180561

507.19

... More
Concealed wiring in looping in system with 2x1.5 sqmm PVC insulated single core cable of 600V grade in heavy gauge PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets fan regulator, bell push etc complete to Power Plug Point with 2x4mm2 including supplying and fitting of 15Amp modular switch socket Combined with continous earth wire to a Power Plug Point Complete.

473

1566661

3312.18

... More
Concealed wiring in looping in system with 2x1.5 sqmm PVC insulated single core cable of 600V grade in heavy gauge PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets fan regulator, bell push etc complete to ceiling fan/ Exhaust Point

27

74126

2745.44

... More
Concealed wiring in looping in system with 2x1.5 sqmm PVC insulated single core cable of 600V grade in heavy gauge PVC pipe including occuping and fitting of elbows, bend, fees, junction boxes etc including required size of MS concealed boxes and front plate for housing of switches, sockets fan regulator, bell push etc complete to Wall point

35

67695

1934.14

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire

875

216780

247.75

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire

875

255857

292.41

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

263

93402

355.14

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

39

18204

466.79

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire

80

48486

606.08

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire

2900

1655876

570.99

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire

1920

1539317

801.73

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire

1128

1205399

1068.62

... More
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

135

195939

1451.41

... More
Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

2615

403178

154.18

... More
32 mm

4140

809978

195.65

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1710

1301862

761.32

... More
300 mm width X 50 mm depth X 1.6 mm thickness

36

36862

1023.96

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

40

66945

1673.63

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

60

81023

1350.39

... More
300 mm width X 50 mm depth X 1.6 mm thickness

4

7876

1969.23

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

4

13814

3453.6

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

31

45586

1470.54

... More
300 mm width X 50 mm depth X 1.6 mm thickness

2

5031

2515.77

... More
450 mm width X 62.5 mm depth X 2.0 mm thickness

4

16191

4047.98

... More
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers & other accessories etc. erected on existing support as per Specification and as per instruction of engineer in charge..

-

-

-

... More
(1) 150 X 50 X 1.6 mm Thick

1219

624366

512.2

... More
(10) 300 X 100 X 2.0 mm Thick

758

701756

925.8

... More
(11) 450 X 100 X 2.0 mm Thick

180

185188

1028.82

... More
(13) 600 X 100 X 2.0 mm Thick

212

240848

1136.08

... More
Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T): 300mm x 38mm x 1.6 mm with Three Compartments

30

49977

1665.93

... More
G.I. Junction cross over box for metal/ Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size with required accessories: 300mm x 300mm x 60/75 mm depth

4

13096

3274.17

... More
CEILING MOUNTED DOWN LIGHT POINT System Wattage : 9W IP- IP 20, LED Driver Integral : Constant Current , Input Voltage : 230-240Vac, Frequency : 50-60Hz, Operating Voltage : 220-240Vac , Operating Temperature : -15°C~+50°C Light Source : LUMILED, LED Lumens : 3300 lm , CRI (Ra) : 80 LED ,Colour Temperature : 3000K / 4000K / 6500K Body : Die-Cast Aluminium , Diffuser : High Efficiency Translucent Polycarbonate ,Mounting : Surface – ,Ceiling Finish : Powder coating White / Black Dimension:-Round Type C.O.D. 160 mm Dia. Power Supply : Integral, THD : 10% , CRI:=80 , Power Factor : 0.9, Surge Protection : 2.5KV ,Efficiency : 80% Colour Temperature : 4000K Luminous flux : 2497 lm Beam Angle : 120° (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

84

165966

1975.79

... More
CEILING MOUNTED DOWN LIGHT POINT System Wattage : 9W IP- 65, LED Driver Integral : Constant Current , Input Voltage : 230-240Vac, Frequency : 50-60Hz, Operating Voltage : 220-240Vac , Operating Temperature : -15°C~+50°C Light Source : LUMILED, LED Lumens : 3300 lm , CRI (Ra) : 80 LED ,Colour Temperature : 3000K / 4000K / 6500K Body : Die-Cast Aluminium , Diffuser : High Efficiency Translucent Polycarbonate ,Mounting : Surface – ,Ceiling Finish : Powder coating White / Black Dimension:-Round Type C.O.D. 160 mm Dia. Power Supply : Integral, THD : 10% , CRI:=80 , Power Factor : 0.9, Surge Protection : 2.5KV ,Efficiency : 80% Colour Temperature : 4000K Luminous flux : 2497 lm Beam Angle : 120° (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

466

1118016

2399.18

... More
CEILING MOUNTED DOWN LIGHT POINT System Wattage : 20W IP 20, LED Driver Integral : Constant Current , Input Voltage : 230-240Vac, Frequency : 50-60Hz, Operating Voltage : 220-240Vac , Operating Temperature : -15°C~+50°C Light Source : LUMILED, LED Lumens : 3300 lm , CRI (Ra) : 80 LED ,Colour Temperature : 3000K / 4000K / 6500K Body : Die-Cast Aluminium , Diffuser : High Efficiency Translucent Polycarbonate ,Mounting : Surface – ,Ceiling Finish : Powder coating White / Black Dimension:-Round Type C.O.D. 160 mm Dia. Power Supply : Integral, THD : 10% , CRI:=80 , Power Factor : 0.9, Surge Protection : 2.5KV ,Efficiency : 80% Colour Temperature : 4000K Luminous flux : 2497 lm Beam Angle : 120° (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

565

1323639

2342.73

... More
CEILING MOUNTED DOWN LIGHT POINT System Wattage : 20W IP- 65, LED Driver Integral : Constant Current , Input Voltage : 230-240Vac, Frequency : 50-60Hz, Operating Voltage : 220-240Vac , Operating Temperature : -15°C~+50°C Light Source : LUMILED, LED Lumens : 3300 lm , CRI (Ra) : 80 LED ,Colour Temperature : 3000K / 4000K / 6500K Body : Die-Cast Aluminium , Diffuser : High Efficiency Translucent Polycarbonate ,Mounting : Surface – ,Ceiling Finish : Powder coating White / Black Dimension:-Round Type C.O.D. 160 mm Dia. Power Supply : Integral, THD : 10% , CRI:=80 , Power Factor : 0.9, Surge Protection : 2.5KV ,Efficiency : 80% Colour Temperature : 4000K Luminous flux : 2497 lm Beam Angle : 120° (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

327

784530

2399.18

... More
TRACK LIGHT WITH ALL ACCESSORIES LIKE HOUSING ETC.. System Wattage: 20W LED Track Light with Track, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING. The luminaire is BIS & CE certifications

589

2078109

3528.2

... More
Tube Light (Ceiling /Wall): SITC of LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD 15%,CCT 4000K (As per Architect), Luminaire efficacy 85 lumens/watt ,LED LED driver efficiency 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature, Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) (A) Tube Light with integral driver (iv) 36 Watts, Surge-2 KV, IP-20, conventional 4 feet

357

755740

2116.92

... More
Hanging Light: Supply, Installation, testing & commissioning of 20W hanging light point System Wattage: 20W LED, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING. The luminaire is BIS & CE certifications

3

31457

10485.81

... More
Suspended Tube Light: SITC of LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD 15%,CCT 4000K (As per Architect), Luminaire efficacy 85 lumens/watt ,LED LED driver efficiency 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature, Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) (A) Tube Light with integral driver (iv) 36 Watts, Surge-2 KV, IP-20

54

647777

11995.88

... More
STEP LIGHT: System Wattage: 3W LED, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP20, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING. The luminaire is BIS & CE certifications"

132

387480

2935.46

... More
Uplighter: System Wattage: 18W LED (6*3watt), Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING. The luminaire is BIS & CE certifications (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)(junction box shall be jelly filled IP-20)

115

1460674

12701.52

... More
Flood Light: SITC of LED Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD 10 %,CCT 4000K (As per Architect),Uniformity ratio 0.45, Luminaire efficacy 100 lumens/watt . LED driver efficiency 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)(junction box shall be jelly filled IP-67) (B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. (v) 2X60 Watt

60

719752

11995.88

... More
WALL MOUNTED UP-DOWN LIGHT POINT: System Wattage : 12W (6x2) LED ,IP 20, IK:07, Driver Integral : Constant Current, Input Voltage : 230-240Vac , Frequency : 50-60 Hz, Operating Voltage : 100-277Vac , Operating Temperature : -15°C~+50°C, DIMENSION ; 145 X 100 x 150mm Body : Extruded & die-cast aluminium , Reflector : Mirror finish pure AL , Diffuser : Clear toughened glass , Mounting : Surface - Ceiling, Finish : Graphite Grey Anthracite Grey Jet Black Light Source : COB LED , Lumens : 1800 lm , CRI (Ra) : 80 , LED Colour Temperature : 3000K / 4000K Power Supply : Integral , Power Factor : ≥0.95 , THD : 85% Luminous flux : 1219 / 1186 lm for 25° Beam Angle : 15° / 25° / 40° (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

137

773381

5645.12

... More
Bulk Head-12W-IP 65: Providing and erecting PVC body surface or pendent mounting LED Bulk type 12 watt Lighting Fitting with electronic driver. And lumen output from luminaire 720lm , input voltage range 90-300VAC , 50Hz cool white(3000 to 6500k), inbuilt driver, -20degC to +60degC working temperature, AL frame with Beam Angle 120deg (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

130

293546

2258.05

... More
PROFILE LIGHT: Supply and fixing of 22w/mtr LED Profile light System Wattage: 22W LED/MTR, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING. (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.)

4

40814

10203.55

... More
Mirror Light 9 Watts, wall mounted-IP65: Supply, Installation, testing & commissioning of Lighting fixtures of approved make suitable for operation at 230V,50Hz complete with housing, ballast, cover and LED lamp with 100 Lumen/watt efficiency as per Technical specifications CRI should be 70. Life : 50000 burning hrs with 70% lumen mainteneace. Surge Protection 2.5Kv for indoor products and 4Kv for Outdoor products. Input Voltage range : 140V-270V AC for all products and as approved by the Engineer. The light fixtures may vary as per Interior/ Architect/ Client requirement

64

261933

4092.71

... More
Strip Light 9W/Meter (IP20): Supply, Installation, testing & commissioning of Lighting fixtures of approved make suitable for operation at 230V,50Hz complete with housing, ballast, cover and LED lamp with 100 Lumen/watt efficiency as per Technical specifications CRI should be 70. Life : 50000 burning hrs with 70% lumen mainteneace. Surge Protection 2.5Kv for indoor products and 4Kv for Outdoor products. Input Voltage range : 140V-270V AC for all products and as approved by the Engineer. The light fixtures may vary as per Interior/ Architect/ Client requirement

1416

399674

282.26

... More
Supplying and fitting of ceiling fan AC Operated type 220/250 volt. Complete with 3nos. Of blades down rod canopy hanging shackle & 30mm length of down rod supplied with the fan by the dealer but the extra length will be charged @Rs2.00/mtrs.

14

61122

4365.91

... More
Supplying and fitting of exhaust fan double bearing self lubricating type single phase 50hz 250v AC operated complete with supporting frame, fan blades,nuts and bolts and other petty accessories as required.

7

20371

2910.25

... More
POST TOP: Supply, Installation, assembling, connection, testing & commissioning of light fixture equivalent to Juno Column Light 60W LED module of NICHIA LED source of CCT 3000K/4000K/5700K. Constructed out of Extruded aluminium bottom pipe of grade- 6063 (with test certificate) Height: 3500mm, Ø100(PIPE DIA) x 2.5mm thickness, FRP type The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in/ loop-out arrangement. The mechanical resistance of the luminaire is IK08 and with ingress protection of IP65. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire 60,000 hours at 40°C. Translucent acrylic diffuser of 1.8mm thickness with controlled downward light emission, lamp fixed position. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency 85%, power factor 0.9, THD 10%, Colour Rendering Index: Ra80 and SDCM MacAdam step 3. Input voltage of 230-240Vac at 50-60Hz frequency and have an operating voltage of 100-277Vac with Surge protection 6KV and have 360 Degree light distribution and simple electronic On-Off driver. The luminaire is BIS & CE certifications. (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) Pole : FRP Type Available finish:- PU coated with MARINE COATING. Dimensions:- Ø600X3500mm.

192

4877383

25403.04

... More
BOLLARD: Supplying and erecting 12W LED Bollard light fittings with High power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminium housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company mark/ name engraved or embossed 120 to 300 V, Power Factor more than 0.95, THD 10 %, CCT 3000 K to 4000K, Uniformity ratio 0.45, Luminaire efficacy 100 lumens/watt . LED driver efficiency 85 %., Sample and Colour Temperature of fixture to be approved from architect. (fittings required LM-79 & LM-80 certificates) (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature, Fixture sample is to be done and approved by the architect and Engineer in charge after sampling and mock-up before finalization.) Tentative Dimension: Ø=166mm, H=900mm LED Bollard fittings of minimum height 900 mm and diameter 166 mm having polycarbonate clear/milky diffuser mounted on 3mm thick aluminium finished powder coated pipe with base plate 160x160 mm with erection by M8x75mm fastener with required RCC foundation IP65 for 16 W, Surge -4KV

280

3161267

11290.24

... More
STREET LIGHT 60W Single Arm: Supply, Installation Testing and Commissioning of LED street light fitting with Min system lumen output of 9000 lumens. Luminaire should be with specially designed heat management system to ensure luminous efficacy 114-120 Lm/w for the system and Power consumption of the luminaire should be maximum 60W. The housing should be of non-corrosive LM6 Pressure Die Cast Housing to with stand extreme environments, it has Anti Dust Exposed Lens. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. Luminaire should be IP68 Protection for LED module and IK09 protection and should meet safety and performance and EMI standards. LEDs Make should be from Lumiled / NICHIA / Osram only. which is having CCT of 4000K/5700 K, CRI 70, SDCM 5 with useful life of L70B50@75000 Hrs Operating Voltage of driver should be of 120 – 277 VAC.The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be disturbed. The Luminaire should have a 10 KV External SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Mid power And COB’s are not permitted. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing mounted inside the luminaire, it has 4 Kv Internal SPD and Thd 10%. Luminaire Weight Should be Not More than 6.5 Kg. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. The Luminaire and Driver both should be BIS approved and CRS no (R no) of both driver and Luminaire along with BIS certificates should be submitted at the time of bid submission.Pole : FRP Type (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) Height– 7000mm. Arm Length- 1145mm. Sq. pipe– 100mm.

66

652011

9878.96

... More
STREET LIGHT 2X60W Double Arm: Supply, Installation Testing and Commissioning of LED street light fitting with Min system lumen output of 9000 lumens. Luminaire should be with specially designed heat management system to ensure luminous efficacy 114-120 Lm/w for the system and Power consumption of the luminaire should be maximum 60W. The housing should be of non-corrosive LM6 Pressure Die Cast Housing to with stand extreme environments, it has Anti Dust Exposed Lens. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. Luminaire should be IP68 Protection for LED module and IK09 protection and should meet safety and performance and EMI standards. LEDs Make should be from Lumiled / NICHIA / Osram only. which is having CCT of 4000K/5700 K, CRI 70, SDCM 5 with useful life of L70B50@75000 Hrs Operating Voltage of driver should be of 120 – 277 VAC.The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be disturbed. The Luminaire should have a 10 KV External SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Mid power And COB’s are not permitted. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing mounted inside the luminaire, it has 4 Kv Internal SPD and Thd 10%. Luminaire Weight Should be Not More than 6.5 Kg. Submission of LM80-08 for LED source & LM79-08 for Luminaire from NABL Accredited Lab mandatory. The Luminaire and Driver both should be BIS approved and CRS no (R no) of both driver and Luminaire along with BIS certificates should be submitted at the time of bid submission. Pole : FRP Type (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature, Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) Height– 7000mm. Arm Length- 1145mm. Sq. pipe– 100mm.

14

276610

19757.92

... More
Uplighter: System Wattage: 18W LED (6*3watt), Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/ Anthracite Grey/ Jet Black with MARINE COATING. The luminaire is BIS & CE certifications. (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) (junction box shall be jelly filled IP-67)

20

723139

36156.99

... More
Tree Uplighter (SPIKE LIGHT): System Wattage: 12W, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60 Hz Operating Voltage: 100-277VAC, Operating Temperature: -15°C~+50°C Light Source: CITIZEN, LED Lumens: 1640 lm CRI (Ra): 80, LED Colour Temperature: 3000K/4000K Power Supply: Integral, Power Factor: 0.98, THD: 10%, Surge Protection: 2.5KV, Efficiency: 84% Colour Temperature: 3000K, Luminous flux: 988 lm, Beam Angle: 15° / 25° / 40° Body: Die-cast Aluminium Alloy, Diffuser: Clear Tempered Glass, Mounting: Spike/ Die-cast Aluminium Bracket Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING, IP66, IK04, Life: 60,000 hrs Dimension: 113 x 84 x 117mm The luminaire is BIS & CE certifications. (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) (junction box shall be jelly filled IP-67)

250

1411280

5645.12

... More
WALL WASHER LIGHT FOR FAÇADE LIGHTING: System Wattage : 15W LED DIMENSIONS - 145 x 100 x 270mm/145 x 100 x 270mm , IP: IP 65 IK 07, Driver Integral : Constant Current , Input Voltage : 230-240Vac Frequency : 50-60 Hz , Operating Voltage : 100-277Vac , Operating Temperature : -15°C~+50°C Physical Body : Extruded & die-cast aluminium, Reflector : Mirror finish pure AL, Diffuser : Clear toughened glass, Mounting : Surface - Wall, Finish : Graphite Grey Anthracite Grey Jet Black Light Source : CITIZEN COB , LED Lumens : 2X900/1800 lm / 2 x 1800 lm CRI (Ra) : 80 LED Colour Temperature : 3000K / 4000K Power Supply : Integral , Power Factor : ≥0.95, THD : 85% Luminous flux : 6W : 615 / 646 lm for 25° / 12W : 1219 / 1186 lm for 25° Beam Angle : 15° / 25° / 40° (NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.) (junction box shall be jelly filled IP-67)

412

5186510

12588.62

... More
STEP LIGHT: System Wattage: 12W LED, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C Light Source: NICHIA, LED Lumens: 1800 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K Power Supply: Integral, Power Factor: ≥0.95, THD: 10%, Surge Protection: 2.5KV, Efficiency: 85% Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs Dimension: 220 x 40 x 95mm. IP66, IK04, Life: 60,000 hrs Finish: Graphite Grey/ Anthracite Grey/ Jet Black with MARINE COATING. The luminaire is BIS & CE certifications.

430

2427401

5645.12

... More
Strip Light 9W/ Meter (IP65): Supply, Installation, testing & commissioning of Lighting fixtures of approved make suitable for operation at 230V,50Hz complete with housing, ballast, cover and LED lamp with 100 Lumen/watt efficiency as per Technical specifications CRI should be 70. Life : 50000 burning hrs with 70% lumen mainteneace. Surge Protection 2.5Kv for indoor products and 4Kv for Outdoor products. Input Voltage range : 140V-270V AC for all products and as approved by the Engineer. The light fixtures may vary as per Interior/ Architect/ Client requirement

788

656132

832.66

... More
Supply, erection, assembling, checking and testing of of decorative external light poles with fittings and clamps as specified in Specification. The unit rate shall also include following: Fixing of pole with Integral Junction box (IP 65/68) with 8. way connector & 2 Nos. of 6 A DP MCB, 38. mm. dia., G.I cable entry & exit conduit as required. Supply and laying of 2 nos. 38 mm. dia.G.I pipe suitable for FRLS XLPE arm cable entry and exit to junction box as required. Concrete coping with base plate & necessary civil works. Earthing and painting. Supply & connecting of wiring from junction box to the light fixture, using 3c x 2.5 sq.mm. PVC copper conductor, flexible cable. Concrete coping with base plate & necessary civil works of excavation and back filling

-

-

-

... More
SITC OF 4.0 Mtr Long, POST TOP LIGHT POLE (FRP Type): Providing and fixing approved make FRP Type Circular poles. The pole should be made as per IS. with required base plate suitable suspend local wind speed to be erected on existing foundation including all other accessories required. 4 Mtr. Long, Top Outer Diameter: 76mm, Bottom Outer Diameter: 142mm, Thickness: 6mm, Base Plate: 250 x 250mm (As per Vendor)

192

4335452

22580.48

... More
SITC OF SINGLE ARM STREET LIGHT POLE (FRP Type): Providing and fixing approved make FRP Type Circular poles. The pole should be made as per IS. with required base plate suitable suspend local wind speed to be erected on existing foundation including all other accessories required. Height- 7000mm, Arm Length- 1145mm, Top Outer Diameter: 114mm, Bottom Outer Diameter: 179mm, Thickness: 6mm, Base Plate: 300 x 300mm (As per Vendor)

66

2747762

41632.76

... More
SITC OF DOUBLE ARM STREET LIGHT POLE (FRP Type): Providing and fixing approved make FRP Type Circular poles. The pole should be made as per IS. with required base plate suitable suspend local wind speed to be erected on existing foundation including all other accessories required. Height- 7000mm, Arm Length- 1145mm, Top Outer Diameter: 114mm, Bottom Outer Diameter: 179mm, Thickness: 6mm, Base Plate: 300 x 300mm (As per Vendor)

14

632253

45160.96

... More
SMART POLE: Supply, Installation, testing and Commissioning of 8 Mtr. Smart pole capable of integrating IoT devices like Camera: HDTV 1080p and 32x optical zoom with Pan, Tilt & Zoom features. It should have forensic WDR , Network camera with With IP66, NEMA 4X and IK10 ratings it’s resistant to both harsh weather conditions and impacts also with MARINE COATING. It is also with two-way audio, I/O ports and extended capabilities for advanced analytics. It should offer electronic image stabilization and enhanced security features including signed firmware and secure boot, PoE Switch, Wi-Fi : 2.4GHz and 5.0GHz bands , Visual display unit (minimum 500x1000 mm, IP 65 Outdoor type, Brightness of 6200CD/m2, 16.7 Mln Colours, Refresh rate of ≥1920HZ ) will be used for display of messages/ Commercialisation of installation, USB charging for Mobile phones/ tablets, Emergency call button, Public address system. Installations and applications and can accommodate telecom equipment from multiple mobile network operators. Pole manufacturers must have production standards certificates per NEN-EN-ISO 9001: 2015, NEN-EN-1090-1. Poles must have EN 1991-1-4 and EN-40 certifications..The smart pole should easily be upgradable to a 4G/5G telecom base station by adding an integrated telecom antenna as a structural part of the pole. Such an antenna should support at least 1695MHz -2690Mhz frequency bands.The smart pole must have 2 external IP67 USB connection ports for mobile device charging application. It must have an IP65 230VAC mains power outlet suitable for outdoor use for general applications. Smart wireless air quality monitoring solution for Air Quality Monitoring, Pollution Control, Industrial and Urban Safety. It should be well connected of below: • Optical Particle Counter: PM1, PM2.5 and PM10μm • Accessible through cloud-based platform. • Easy to configure through Laptop, Smartphone or Tablet • Rechargeable Lithium battery with power path. • GNSS: GPS/Glonass with 2.5 meters accuracy. • Built-in temperature, battery and RSSI sensors. Remote configurable alarms, thresholds, calibration parameters, readings and transmissions periods. This job is including Installation, Programming & Commissioning of smart pole as per requirment & latest specifications. Equivalent to Philips UrbanWit SMart pole The scope shall also cover to supply and installations of all components like Power supply modules, POE switch, LC, SC modules and all other require/ necessary components and accessories to finish and operate smart pole satisfactory.

2

4233840

2116920

... More
Construction of Foundation for POST TOP LIGHT Pole of size 300mm Length, 300 mm width, 600mm depth including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes R.C.C work of M-25 for foundation also having 100mm thick PCC in M-10 and 150mm thick rubble soling at bottom level. It shall be completed with all respect in true line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction. (Foundation should be designed as per wind speed of local area guidelines.)

274

905570

3305

... More
Construction of Foundation for STREET LIGHT Pole of size 450mm Length, 450 mm width, 600mm depth including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes R.C.C work of M-25 for foundation also having 100mm thick PCC in M-10 and 150mm thick rubble soling at bottom level. It shall be completed with all respect in true line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction. (Foundation should be designed as per wind speed of local area guidelines.)

80

377200

4715

... More
Construction of Foundation for BOLLARD of size 300 mm Length, 300 mm width, 450 mm depth including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes R.C.C work of M-25 for foundation also having 100mm thick PCC in M-10 and 150mm thick rubble soling at bottom level. It shall be completed with all respect in true line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction. (Foundation should be designed as per wind speed of local area guidelines.)

280

690200

2465

... More
SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.

210

11387

54.23

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

130

947559

7288.92

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

1820

472189

259.45

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

15

18533

1235.56

... More
Providing and fixing Earthing Strip of 50x6mm Hot Dip Galvanized GI strip

700

225240

321.77

... More
Providing and fixing Equipotential Busbar of 50x6mm Hot Dip Galvanized iron.

12

5893

491.13

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

1452

381346

262.64

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)

506

157104

310.48

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 160 mm dia (OD-160 mm & ID-135 mm nominal)

2340

1196785

511.45

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal)

2485

1765055

710.28

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required: 100 mm dia

100

70390

703.91

... More
Construction of ELECTRICAL & ELV chamber of size 450x450x600 (1050x1050x850)mm including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes brick work of Walls, R.C.C work of M-25 for top and bottom slabs, also having 100mm thick PCC in M-10 at bottom level. It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water proofing and outside of chamber with 18mm thick cement plaster(underlayer 12 mm thick cement plaster 1 :5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ) in two coat at all sides. Top shall be covered with Pre-Cast SFRC Solid MH cover with clear opening of 450x450mm with frame and cover bearing load min. 25t and size as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

41

652884

15924

... More
Construction of ELECTRICAL & ELV chamber of size 750x750x1000 (1550x1550x1250)mm including excavation, backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C work of M-25 for walls, top and bottom slabs, also having 100mm thick PCC in M-10 at bottom level. It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water proofing and outside of chamber with 18mm thick cement plaster(underlayer 12 mm thick cement plaster 1 :5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ) in two coat at all sides. Top shall be covered with Pre-Cast SFRC MH cover with clear opening of 900x900mm with frame and cover bearing load min. 25t and size as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

31

1241085

40035

... More
Construction of ELECTRICAL & ELV chamber of size 1000x1000x1200 (1800x1800x1450)mm including excavation, backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C work of M-25 for walls, top and bottom slabs, also having 100mm thick PCC in M-10 at bottom level. It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water proofing and outside of chamber with 18mm thick cement plaster(underlayer 12 mm thick cement plaster 1 :5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ) in two coat at all sides. Top shall be covered with Pre-Cast SFRC MH cover with clear opening of 900x900mm with frame and cover bearing load min. 25t and size as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

15

1000200

66680

... More
Construction of ELECTRICAL & ELV chamber of size 1500x1500x2000 (1900x1900x2000)mm including excavation, backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C work of M-25 for walls, top and bottom slabs, also having 100mm thick PCC in M-10 at bottom level. It shall be plastered with 15mm thick Plaster with neat coat in CM 1:3 on internal including water proofing and outside of chamber with 18mm thick cement plaster(underlayer 12 mm thick cement plaster 1 :5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 ) in two coat at all sides. Top shall be covered with Pre-Cast SFRC MH cover with clear opening of 900x900mm with frame and cover bearing load min. 25t and size as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

15

1760460

117364

... More
Construction of Plinth for OUTDOOR ELECTRICAL PANAL of size 1500x500x300 mm including excavation, backfilling, watering, soling, compaction, reinforcement etc. complete. It includes R.C.C work of M-30 for plinth also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick sand faced cement plaster in two coat at all sides and paint with exterior grade paint/ sides shall be finised/ cladded with kota stone, size as mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

8

232096

29012

... More
Construction of Plinth for Trench of size 750x750x1000 mm including excavation, backfilling, watering, soling, compaction, reinforcement etc. complete. It includes R.C.C work of M-30 for plinth also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick sand faced cement plaster in two coat at all sides and paint with exterior grade paint/ sides shall be finised/ cladded with kota stone, size as mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

5

1238110

247622

... More
Supplying, installation, testing and commissioning of ON LINE UPS system with SMF battery and 30 min back and with battery rack complete in all respect. 1 set. of 7 KVA UPS Single phase input & Single phase output for unbalance (Emrg. Ltg.+Computer+Elv) load.

8

1190896

148862

... More
Supplying, installation, testing and commissioning of ON LINE UPS system with SMF battery and 30 min back and with battery rack complete in all respect. 1 set. of 5 KVA UPS Single phase input & Single phase output for unbalance (Emrg. Ltg.+Computer+Elv) load.

2

212660

106330

... More
Supplying, installation, testing and commissioning of ON LINE UPS system with SMF battery and 30 min back and with battery rack complete in all respect. 1 set. of 2 KVA UPS Single phase input & Single phase output for unbalance (Emrg. Ltg.+Computer+Elv) load.

6

255192

42532

... More
Supply, Transportation, Installation, testing and commissioning of IP-67 Rated weather proof Outdoor type junction boxes having dimensdios Height x Width x Depth:- 104 x 104 x 70 mm with terminal having black colour RAL 7035.

10

9836

983.66

... More
Supply, Transportation, Installation, testing and commissioning of IP 66/69 weather proof Outdoor type junction boxes having dimensdios Height x Width x Depth:- 155 x 210 x 92 mm having black colour RAL 9011.

10

22778

2277.81

... More
Supply, Transportation, Installation, testing and commissioning of IP 66/69 weather proof Outdoor type junction boxes having dimensdios Height x Width x Depth:- 155 x 210 x 92 mm with terminal having black colour RAL 9011.

10

29933

2993.33

... More
Supplying, installation, testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

5

24466

4893.31

... More
Designing, Supply, installation ,Testing & Commissioning of structurally Integrated lightning protection system confirming to IS/IEC 62305-3,NBC 2016 and IS 3043. includes following items/ consider as per drawing : 1. 8 sq. mm AL conductor including fixing including clamp, expansion Joints 2. Vertical Air terminals (1 or 3 Mtr.) 3. lightning counter including fixing with clamp - 4. Expansion joint , splicers for conductor including fixing with clamp - 5. Stainless steel 304 GRADE of polyamide /stainless/ brass holder for fixing the aluminum downconductor on ring - 6. Stainless steel 304 GRADE Universal T connector for 8 mm Aluminium Round Conductor to connect with mesh on roof slope - 7. 10 mm dia copper. bonded down conductor including fixing including clamp, expansion Joints 8. Bonding /Rebar Clamp suitable for 32 mm dia for interconnecting round conductor with reinforcement inside the concrete for structural earthing system should be tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform 9. Cross Splicer for 8 mm & 10 mm conductor 10. Earthing stud of dimension SS-75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to meet the requirements of IS/IEC 62305 9. Disconnection link for 8 mm aluminium conductor 10. connector -To connect air terminal 8-10 mm with earth fixing point to meet the requirements of IS/IEC 62305 11. 10mm dia copper bonded from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating with holder 12. Electrode Cu Bonded Steel Rod 14.2mm dia x 3000mm-(250Microns);Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with followingdimensions :254 mm dia (top), 330 mm dia (bottom) & 260mm (height);14.2 / OD SS Clamp Both Side; Carbon based backfillcompound - 25Kg Also, Any other Item Not included above but required to complete the Job. Quantities of above items are considered as per Tender drawings.

-

-

-

... More
For A & B Block

1

1016422

1016422.32

... More
For C & D Block

1

893444

893444.22

... More
For E Block

1

475077

475077.38

... More
For G Block

1

405661

405661.29

... More
For H Block

1

740587

740587.08

... More
For I Block

1

620359

620359.27

... More
Fire Stop Foam Supply and installtion of expanding firestop foam equivalent to Hilti CP 620 on both sides of wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The system shall be UL listed & classified. The system shall be UL & FM approved.

23

223970

9737.83

... More
Fire stop mortar system Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum 2 hours fire rating when tested in accordance with UL 1479/ ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system shall be UL listed. The gaps around inaccessible or complicated openings shall be sealed with exapnding firestop foam.

38

804429

21169.2

... More
Firestop Sealant Supply and installatio of Acrylic Firestop Sealant equivalent to Hilti CP 606 in gaps between wall and slab made of concrete/masonary/gypsum on both sides of wall to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. The product shall be age tested as per Dafstb and DIBT standards.Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4.

23

28402

1234.87

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
Telephone socket outlet

5

786

157.37

... More
RJ-45 Data/ LAN Socket

156

131435

842.53

... More
Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)

161

51014

316.86

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module

161

22768

141.42

... More
SITC of ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm

140

21585

154.18

... More
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction. [C] CAT - 6

200

12121

60.61

... More
SITC of CCTV System complete with all items mentioned but not limited to below: - In general the complete system design and installations shall confirm to latest IEC guidelines and the specifications, drawings submitted here with; Supply, installation, testing and commissioning of Cat 6 cable. Supply, Installation,testing and commissioning of 24 Port POE Network Switch to provide Power and Data Communication for mentioned Camera with 1 G SFP Module.

-

-

-

... More
SITC of ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm

5205

802501

154.18

... More
Supply, Installation, Testing and Comissioning of 2 MP Fixed Lens Dome Type Camera - H.265 2 MP IR Vandal Proof Dome N/W Camera, 2.8mm/3.6mm, 30M IR, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 1 / 2.7" CMOS, 2560 × 1440, 0.01 Lux, F1.2, AGC ON; Defog, True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Basic intelligent video analytics, NDAA Compliance, UL, CE, FCC Certified

156

1133822

7268.09

... More
Supply, Installation, Testing and Comissioning of 2 MP Motorised Varifocal Lens Bullet Camera - H.265 2MP IR Bullet N/W Camera, Motorised Varifocal 2.8-12mm, IR up to 70M, Micro SD support up to 128GB, DC12V/PoE, IP67/IK10, Basic IVA, 2 MP resolution (1920 × 1080), True day/night, WDR @ 120dB, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Intelligent video analytics, NDAA Compliance, UL,WEEE, REACH CE, FCC Certified, IK10 & IP67, Opp Temp - 30 °C to 60 °C, ONVIF S,G,T

140

1145959

8185.42

... More
Supply Installation Testing & Commissioning of IP based, Keyboard Joystick supporting: - 3-axis variable speed joystick with zoom controls - LCD for system feedback - Video system control: Camera and camera grid selection, Monitor selection, Playback control. - Dedicated keys for PTZ call, sequence selection, tours. - Programmable Function Keys - Power over Ethernet - Web browser for simple configuration and firmware upgrades - UL, CE/EN/ FCC certified

1

169494

169494.73

... More
Supply, Installation, Testing & Commissioning of 64 Chanel at 1080P and high decoding capability for Ultra 4K HD viewing and recording, H.265, H.264 codec decoding, Internal storage support for 8HDD & RAID 0,1,5,6,10.

2

735418

367709

... More
Supply, Installation, Testing & Commissioning of 32 Chanel at 1080P and high decoding capability for Ultra 4K HD viewing and recording, H.265, H.264 codec decoding, Internal storage support for 8HDD & RAID 0,1,5,6,10.

9

817965

90885.02

... More
Supply, installation, testing & commissioning of Client Workstation as per following specifications:Intel® Core™ Intel Core i7-13700, 4 core, 8MB Cache, OS - Genuine Microsoft Windows® 10 Enterprise 64-bit, RAM - 16GB, Hard Drives - 500 GB 7200RPM SATA3, Video Adaptor - Integrated Intel UHD graphics 630 and NVIDIA Quadro P620 supporting 4 Monitors over HDMI/VGA, Network Connection - 1 Gbit/sec or greater, Two(2) PCI-Express Expansion Slots 2/4 USB, CD/DVD ROM, USB Keyboard and Mouse, UPS, associated cables etc complete as required

12

1277434

106452.85

... More
Supply and Installtion of Outdoor type Box suitable to install Data socket, media converter, 6A, power socket, LIU box. Rate shall include 2 nos of Data socket and 2 no of 6A socket with JB. (500 x 400 x 200 )

8

96418

12052.33

... More
Supply, Installation and Testing of 12 C Splicing LIU BOX

16

124192

7762.04

... More
SITC Of Fiber Optic Patch Cable (SC-LC), upto 3 Mtrs. Long, ISO/IEC-11801-OM3 50μ Duplex, All patch cords shall conform to EIA/TIA-568C.3 and ISO/IEC-11801 Shall be Duplex Multi Mode Fiber Optic Patch Cords OM3 50μ Attenuation ≤0.3dB measured at 850nm Acc to IEC 61300-3-4 Method B Return Loss ≥ 30dB, Patch cords shall be factory terminated, Jacket Material–LSZH with neccessory connections

32

155805

4868.92

... More
Supply, Installation and Testing of Media Convertor SM 10 Km Range

18

317538

17641

... More
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction [C] CAT - 6

2150

130307

60.61

... More
Supply, Installation, Testing & Commissioning of 16U (600W X 500D) Pre-configured Pole/Wall mount closed rack with front glass door,With fan, Cantilever tray, 5A 6 Sockets power strip with hardware Screw Packet.IP65 having RAL 7035 (Light Grey) texture finish color with 4 nos. 50 dia rubber grommets for cable entry on top and bottom cover both. UL, CSA, TUV, EIA 310, DIN 41494, EIA 310, DIN 41494, ISO 9001, ISO 14001, OHSAS 18001, IEC 297 complied rack

2

26814

13407.16

... More
Supply, Installation, Testing & Commissioning of 9U (600W X 500D) Pre-configured Pole/Wall mount closed rack with front glass door,With fan, Cantilever tray, 5A 6 Sockets power strip with hardware Screw Packet.IP65 having RAL 7035 (Light Grey) texture finish color with 4 nos. 50 dia rubber grommets for cable entry on top and bottom cover both. UL, CSA, TUV, EIA 310, DIN 41494, EIA 310, DIN 41494, ISO 9001, ISO 14001, OHSAS 18001, IEC 297 complied rack

9

95896

10655.16

... More
SITC of Jack Panel, fully loaded with 24 nos. UTP ports for PCB based IO Jacks (RJ45, TIA-568C Category-6, Installation and Termination of all 24 nos. Catergory-6 UTP , unloaded with individually replaceable 24 nos. Category-6 I/O Jacks complying with TIA-568.C.2, as per given jack specification Shall be suitable for loading unshielded & shielded jacks for different category systems (CAT 6 & CAT 6A)

18

82559

4586.66

... More
SITC of 24 x 10/100/1000BASE-T PoE ports 4 x Gigabit RJ45/SFP Combo ports Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface 193 W PoE budget

18

1003420

55745.56

... More
Supply, instalaltion,Tesitng and commisioning of LAYER 3, 16 Port 10/100/1000Mbps & 4 ports for SFP/ SX Modules supporting 10 G, Stacking cable (Non-blocking switch fabric, IPv6 ready), option for RPS (Should have per port power budget of 15.4W, when fully populated). Vendor shall furnish all necessary accessories of networking required for IPCCTV. All necessary approvals as required at the direction & final directions of Consultants.

1

130302

130302.07

... More
SITC of company fabricated patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shall support network line speeds up to 1 Gbps Shall have RJ-45 jacks. (B) 2 Mtr

42

14818

352.82

... More
SITC of company fabricated patch cords shall conform to Cat- 6 & conductor shall be stranded for better flexibility Shall support network line speeds up to 1 Gbps Shall have RJ-45 jacks. (A) 1 Mtr

160

40644

254.03

... More
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections as per site situation directed by Engineer In charge. [A] For One Gang (8) Computer RJ-45 socket CAT-III

44

52781

1199.59

... More
SITC of Faceplate for RJ45 Port with ABS /Metal Body square plate, dimension as per commercially available modular office furniture. Shall Have Icons, Shutter, Screw Cover, Label Cover, Jack holder with neccessory connections (A) 1-port

44

65511

1488.9

... More
Supply, Installation, Testing & Commissioning of 42U (800W X 1000D) floor mount closed rack complied with UL, CSA, TUV, EIA 310, DIN 41494, ISO 9001, ISO 14001, OHSAS 18001, IEC 297 and current industry practices, CRCA Steel Door - Plain, Vented at Bottom, Fully perforated at front and rear side, with screw fitted side panels. 19" L type mounting angles at front and rear, top and bottom cover with cable entry provision, loading rate of 1200kg, with required accessories .

2

111491

55745.56

... More
SITC of 24 x 10/100/1000BASE-T ports 4 x Gigabit RJ45/SFP Combo ports Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface

2

68644

34322.33

... More
Supply, Installation and Testing of 6 Port LIU

7

35366

5052.38

... More
Providing & erecting Optical Fiber cable should be ISO/IEC- 11801 , Outer sheath FRLSZH Shall be 9µ, Single mode OS2 steel armoured cable as per ISO/IEC- 11801 Shall be able to meet Gigabit & 10 Gigabit Ethernet performance requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10GBase-X) Shall have water blocked construction to prevent water absorption and consequent damages. Water blocking with flooding Gel and water blocking yarn shall comply for IEC 60332-3 for flame retardant, IEC 61034- 2 for low smoke & IEC 60754-2 for toxicity & acidity. Tensile load should be 2700 Newton or higher Optical Parameters – SM, (a) Attenuation @ 1310nm(max) ≤ 0.34 dB/Km, (b) Attenuation @ 1550nm(max) ≤ 0.22 dB/Km with neccessory connections (A) 6 core Single mode

1950

123840

63.51

... More
Supply, Installation, Testing and Commissioning of Wirelss Access Point shall have IEEE 802.11ac, 802.11n, 802.11g, 802.11b, 802.3af, 802.3u, 802.1X (security authentication), 802.1Q (VLAN),802.1D (Spanning Tree), 802.11i (WPA2 security), 802.11e (wireless QoS), IPv4 (RFC 791), IPv6 (RFC 2460),LAN Gigabit Ethernet auto- sensing,10/100/1000 Ethernet, with support for 802.3af /at PoE, power port for AC adapter (included) Make :- CISCO,NetGear,HP

7

193825

27689.31

... More
Supply, Installation, Testing and Commissioning of Hardware based OR Sotware based Wireless Access Controller, License with Minimum 50 Access point and support up to 100 access point as required.

1

14437

14437.39

... More
Design, Supply, Install, Testing of all Fire Alarm Components and Commissioning of a Complete New Automatic Analog Addressable type Fire Alarm and Detection System complete with all items mentioned but not limited to below: - In general the complete system design and installations shall confirm to latest NFPA guidelines and the specifications, drawings submitted here with. The detector shall not require any special tool/software/PC to set address to each device to avoid end user's dependency on specific OEM/ System integrator.

-

-

-

... More
Supply, Installation Testing and Commissioning of wall/ floor-cum-wall/ 19" rack mountable micro processor based, interactive, modular, intelligent and adressable, networkable, programmable from PC or Via on board keypad/touch screen, explandable upto 2 loops main fire detection, control & indication Panel complete with CPU, LCD, display, operating terminal, detection loop, control loops, power supply module, battey charger drycell maintenace free battery of suitable capacity with in built battey charger, housing complete as required. The panel shell be loade with auto dialler for triggering alarm signals via SMS on at least 10 nos ofmobile phones and 10 nos of direc telephone numbers as assigned and programmed for (B) 2 Loop Panel

9

1696449

188494.38

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

2475

944769

381.73

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

90

26412

293.47

... More
Supply of intelligent, addressable twin angle optical smoke cum thermal heat multisensor detectors (complete assembly)with inbuilt microprocessor, memory and decision algorithm, CPU failure mode, status indicator, with in built fault loop isolator and standard detector base with NO DIP/ ROTARY or Mechanical address switch but soft programmable or alternatively Laser type spot multisensing detector.

403

2004997

4975.18

... More
Supplying of surface mounted Sounder cum flasher for fire alarm system with built in isolator complete as required. Sound output minimum upto85db

36

298574

8293.74

... More
Suppling of wall mounted addressable type microprocessor based manual call point with built in loop isolator and all accessories comlete as required

36

175202

4866.72

... More
Supply of intelligent, addressable Optical smoke detector cum flasher with inbuilt microprocessor, memory and decision algorithm,CPU failure mode, status indicator, with in built fault loop isolator and standard detector base with NO DIP/ ROTARY or Mechanical address switch but soft programmable.or alternatively Laser type spot multisensing detector.

22

101360

4607.28

... More
Supplying, installation, testing & commissioning of addressable fire control module having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required.

20

63861

3193.09

... More
SITC of Fast Response Contact Monitoring Module. The Module shall have UL 864 9th Edition Listed, Single Input contact monitor, can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts, operates on Class A or Class B SLC loop, Accepts up to 12 AWG wire. Approved by UL and FM

21

164514

7834.02

... More
SITC of ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25mm

1425

219705

154.18

... More
Supplying, installation, testing & commissioning of fire fighter phone jack having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required.

21

35726

1701.28

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required.

21

128170

6103.34

... More
Any other Item Not included above but required to complete the Job:- Control Wiring & required Terminations from Flow Switch/ Tamper Switch/ other Mechanical Equipment, Starter Panel from respective Control Module or Monitor Module shall be in Contractor Scope. [Bidder shall list each item here under and a detailed Rate Analysis to be submitted along with commercial bid.]

1

10633

10633

... More
Providing & erecting Following capacity Amplifier WITH BUILT-IN DIGITAL PLAYER , MEDIUM WATTAGE PA MIXER AMPLIFIER, Built-in MP3 player with remote control for USB, SD/MMC card reader approx 2% THD ,Frequency Response :- 50-15,000Hz ±3dB Tone Controls -Bass:Treble ,Speaker Output :- 4Ω, 8Ω, 70V & 100V ,Digital Player MP3 Player with USB, SD and MMC Card Reader. (C) 500 Watts (max 750 W RMS output)

2

119535

59767.71

... More
SITC of High power 2-way flush mount ceiling / wall speaker for excellent reproduction , Wide frequency response and adjustable tweeter for optimum directivity. following Input Power ,Impedance :- 500/1k/2kΩ ,Frequency Response :- 90-18,000Hz ,SPL at 1kHz (1W/1m) :- 91dB erected as directed by engineer in charge (A) 30 Watt Woofer 150mm (5”), Tweeter 25mm (1”)

10

189111

18911.15

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. (A)Speaker cable Single pair, 2-core, 1.5 sqmm

250

38810

155.24

... More
6 Zone Digital PAVA Controller, Complies to international standards, Plug & Play for easy commissioning, Fully configurable keys, Modular architecture Expandable up to 32 Zone (64 Speaker Lines), zone control, Dual channel audio, Extension Amplifier backup, Extension router, PTT MIC, Digital volume control, Fault detection and indication

1

296975

296975.65

... More
Design, Engineering, Supply, Installation, Testing & Commissioning of 40 kWp Grid Connected Solar PV Power Plant for 10Hrs. consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink, etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.

2

5758022

2879011.2

... More
Design, Engineering, Supply, Installation, Testing & Commissioning of 20 kWp Grid Connected Solar PV Power Plant for 10Hrs. consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink, etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.

6

8891064

1481844

... More
EV Charging Station (Four Wheeler)- 7.4KW Type-2 EV Charger with CCS Single Type-2 Gun Supply, installation, testing and commissioning of wall mounted/floor standing charging station for two wheeler with Single charging socket as mentioned below with all require components and accessories to finish the job. Rquire solution for Payment gateway and related software (Charging management software) shall be part of scope. All require components and accessories to operate setisfactory shall be part of contractor's scope. AC Charger-1 (7.4KW Bus Charger, CCS2 Single Type-2 Gun )

5

290723

58144.74

... More
EV Charging Station (Four Wheeler)- 7.4KW 2Nos. Type-2 EV Charger with CCS Single Type-2 Gun Supply, installation, testing and commissioning of wall mounted/floor standing charging station for two wheeler with Single charging socket as mentioned below with all require components and accessories to finish the job. Rquire solution for Payment gateway and related software (Charging management software) shall be part of scope. All require components and accessories to operate setisfactory shall be part of contractor's scope. AC Charger-1 (7.4KW Bus Charger, CCS2 Single Type-2 Gun ) AC Charger-2 (7.4KW Bus Charger, CCS2 Single Type-2 Gun )

2

170736

85368.33

... More
EV Charging Station (Polo Cart/Mini Bus) - 3.3 KW - (3.3 kw X1 nos.) 3 Pin 15A Socket Outlet Supply, installation, testing and commissioning of wall mounted/floor standing charging station for two wheeler with Single charging socket as mentioned below with all require components and accessories to finish the job. Rquire solution for Payment gateway and related software (Charging management software) shall be part of scope. All require components and accessories to operate setisfactory shall be part of contractor's scope. Charger (3.6KW OCPP Enabled Charger, 3 Pin Plug Outlet )

7

518339

74048.45

... More
Supplying, installation, testing and commissioning of 250 KVA DG set with AMF Logic control panel with suitable BHP engine, with suitable alternator complete with all necessary fuel piping, exhaust piping, silencer & its piping, Acoustic silencer, base frame, battery and charger complete in all respect. Scope also includes preparing necessary drawing submitting to authorities, getting their approval/ sanction and final certificate including NOC from pollution board (if required) to energize the D G Set.

4

12983776

3245944

... More
Providing and Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. 6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683

72

243360

3380

... More
Providing and Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets and shall conform to IS 2878.

119

1007930

8470

... More
Supplying, installation testing and commissioning of CLEAN AGENT Automatic Modular(Self Activated) fire extinguisher Automatic type 5 kg Fire Extinguishers, Applicable fire classes A,B & C, UGTS Pressure Gauge, Empty Weight 2.64 kg, Full weight 7.64 kg, Can Height 370mm, Diameter 230 ± 10mm, Made up from 2 mm thick sheet,, Body Construction Deep Drawn with MIG Welding technology, Brass forged sprinkler valves with Nozzle is specially designed to give more than 99% discharge. Together with orifice characteristic to cover adequately fire risks with scattering cone of 40 to 45° Angle. Internal & External Pure polyester (UV Resistant) powder coated, Heat Sensitive Glass bulb of 68 °C. including pressure indicating gauge, celling mounted bracket.

44

1003640

22810

... More
Supplying, installation testing and commissioning of CLEAN AGENT Automatic Modular (Self Activated) fire extinguisher Automatic type 15 kg Fire Extinguishers Applicable fire classes A,B & C, UGTS Pressure Gauge, Empty Weight 6.40 kg, Full weight 21.40 kg. Can Height 425mm, Diameter 400 ± 10mm, Made up from 2 mm thick sheet,, Body Construction Deep Drawn with MIG Welding technology, Brass forged sprinkler valves with Nozzle is specially designed to give more than 99% discharge. Together with orifice characteristic to cover adequately fire risks with scattering cone of 40 to 45° Angle. Internal & External Pure polyester (UV Resistant) powder coated, Heat Sensitive Glass bulb of 68 °C including pressure indicating gauge , celling mounted bracket.

1

66200

66200

... More
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. AUTOGLOW signages in Block/ Small letters of Specified Sizes: Fire Hydrant: 4" X 12"

49

23765

485

... More
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. AUTOGLOW signages in Block/ Small letters of Specified Sizes: "ABC" Extinguisher: 8" X 4"

72

23760

330

... More
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. AUTOGLOW signages in Block/ Small letters of Specified Sizes: "CO2" Extinguisher: 8" x 4"

119

39270

330

... More
Supplying, fixing, testing and commissioning of ‘C' class GI pipe (6 mm thick IS 3589) as per IS1239 with welded/ flanged/ screwed joints and also include Design, Fabrication, Supply, installation, testing & commissioning of all the engineered support as per detail technical specification, supports, guides, anchors, etc. including all fresh plate, channel, angles, beams, hardwares, etc,. Complete , heavy clamps, hangers, brackets or pipe supports (all with screwed/welded joints) as required including MS C class pipe of shorter lengths, tapering connecting pieces, short or long bends, MS C class specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. complete to make the system operative as required by LFA/ authorities. The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work includes making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect/ Consultant/ Client and painting two coats of approved shade (Post office red)of enamel paint over a coat of approved primer for over ground/ overheads pipes. Note: The piping installation has to be put to hydraulic test to 1.5 times the working pressure & as per latest applicable code & standard before applying paint etc. complete. 300 mm dia. Pipe

12

117516

9793

... More
250 mm dia. Pipe

12

102048

8504

... More
200 mm dia. Pipe

23

182551

7937

... More
150 mm dia. Pipe

954

5066694

5311

... More
125 mm dia. Pipe

271

1159067

4277

... More
100 mm dia. Pipe

636

2294688

3608

... More
80 mm dia. Pipe

1137

2897076

2548

... More
65 mm dia. Pipe

1027

2079675

2025

... More
50 mm dia. Pipe

1571

2529310

1610

... More
40 mm dia. Pipe

1526

1761004

1154

... More
32 mm dia. Pipe

1031

1020690

990

... More
25 mm dia. Pipe

6699

5406093

807

... More
Supplying, installation testing and commissioning of underground pipe the following ‘C’ class GI Pipe as per IS : 1239-1973 tested to 200 PSI complete with fitting and welding of pipes and fittings wherever required complete with flanges and painting , underground pipes with welded/ flanged/ screwed connection with saddles, supports (all with screwed/ welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. complete to make the system operative as required by LFA authorities the pipes will have to be laid and fixed in trenches. making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over heads pipes and providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc. complete as per ASTM standards/IS:10221 for corrosion protection of pipes for the under ground installation. Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure and as per latest applicable codes and standard before applying paint or pipe coating or wrapping etc. complete. 200 mm dia. Pipe

1

8335

8335

... More
150 mm dia. Pipe

2448

13647600

5575

... More
100 mm dia. Pipe

275

1041700

3788

... More
80 mm dia. Pipe

638

1706650

2675

... More
50 mm dia. Pipe

1

1690

1690

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete. 300 mm dia. Pipe

248

252890

1019.72

... More
250 mm dia. Pipe

11

10062

914.78

... More
150 mm dia. Pipe

11

6191

562.86

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095. 150 mm dia.

51

470267

9220.94

... More
100 mm dia.

18

123142

6841.24

... More
80 mm dia.

14

71855

5132.52

... More
65 mm dia.

6

26387

4397.94

... More
50 mm dia.

2

7782

3891.26

... More
40 mm dia.

4

14878

3719.54

... More
Supply and installation, testing and commissioning of ball valve, PN 16.0 tested to 1.5 times working pressure with necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position as per fire practice etc. complete. 32 mm dia.

1

3140

3140

... More
25 mm dia.

3

5490

1830

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI rnarked complete with nuts, bolts, washers, gaskets and conforming to lS 780 of following sizes as required: Size : 250 mm

1

49097

49097.08

... More
Size : 200 mm

7

290366

41480.98

... More
Size : 150 mm

9

215127

23903

... More
Size : 100 mm

1

15293

15293.68

... More
Size : 80 mm

1

11181

11181.94

... More
Size : 65 mm

1

9629

9629.04

... More
Size : 50 mm

1

7519

7519.64

... More
Size : 40 mm

1

5955

5955.08

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal cap and chain as required : Single Headed Gunmetal

49

389238

7943.64

... More
Supplying and fixing Single headed external yard hydrant valve with 1No. 63 mm dia instantaneous FM Gunmetal Stainless Steel coupling andcast iron wheel, ISI marked, conforrning to IS 5290 (type A) with blank Gunmetal/ Stainless Steel cap and chain as required : Single Headed Gunmetal

45

357463

7943.64

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

188

1033864

5499.28

... More
Providing and fixing as per ISO fire hose cabinet size 600x 750x 250mm to house fire hydrant and hose, including all other related accessories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated and painted with post office red colour of size as shown in the drawing (or as approved by Architect) to house the hydrant valve, 15m x 2 No. hose and hose reel.

49

359660

7340

... More
Providing and fixing approved fire hose cabinet stand mount type for external size 600 x 750 x 250mm to house fire hydrant and hose, including all other related accessories fabricated from M.S. sheet (14 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated and painted with post office red colour of size as mentioned in drawing (or as approved by the Architect) to house 15m x 2 No. hoses.

45

363375

8075

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required 20 mm nominal intemal dia water hose thermoplastic (Textile reinforced) We -2 as per IS: 12585, 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 40m

49

524178

10697.52

... More
Supplying and fixing stand mount First-aid Hose Reel with MSEP Fabricated Stand MS construction and spray painted in post office red, conforming to IS 884 complete with the following as required 20 mm nominal intemal dia water hose thermoplastic (Textile reinforced) We-2 as per IS: 12585, 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on stand, connections from riser with 25 mm dia stop gun metal valve, M.S. Pipe and socket including faricated stand for mount hose reel in external for 40m.

45

499500

11100

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

94

128635

1368.46

... More
Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air release valve PN 16 with 25 mm dia ball valve on inlet side and pressure gauge with isolating cock.

8

24800

3100

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

94

239335

2546.12

... More
Providing and fixing 100 mm diameter sand cast Iron grating with Frame For FHC drain

8

5880

735

... More
Providing and fixing of pump trigger system On / Off switch for Fire Hydrant Main Pump as per CFO requirement.

49

46305

945

... More
Earthwork in excavation by Mechanical means up to a depth of o-2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

3024

1365517

451.56

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. ii) Earth Filling (For Marshy Soil)

1218

1337895

1098.44

... More
Sand filling in plinth in layers not exceeding 150 mm thick including breaking of clods, consolidating by ramming and watering complete as directed. (maximum depth 45 cm)

1758

3520113

2002.34

... More
Construction of Valve Chamber of size 750x750x1500 (1200X1100X1700)mm including excavation, backfilling, watering, soling, compaction, reinforcement, rungs etc. complete. It includes R.C.C work of for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with 20mm thick sand faced cement plaster in two coat at all sides. Top shall be covered with FRP surface heavy duty Recess Manhole cover with clear opening of 600x600mm with frame and cover as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

5

311952

62390.54

... More
Construction of Valve Chamber of size 750x750x1500 (1200X1100X1700)mm including excavation, backfilling, watering, soling, compaction, reinforcement, rungs etc. complete. It includes R.C.C work of for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with 20mm thick sand faced cement plaster in two coat at all sides. Top shall be covered with FRP surface heavy duty Solid Top Manhole cover with clear opening of 600x600mm with frame and cover as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

4

259352

64838.08

... More
Construction of RCC Thrust Block foundation having size of 700X700X700 mm with RCC as per drawing and having 100mm thick PCC in at bottom level . It includes excavation, back filling, ramming, watering, casting, fair finish shuttering, reinforcement, binding wires, etc. complete in true line level and plum in radiant or level as per detailed design drawing. Contractor shall clean up entire drain and manhole before handing over procedure.

55

502487

9136.14

... More
Supplying & installing completely testing & commissioning of centrifugal main fire pump(electrical driven) for hydrant main / sprinkler main with cast iron casing & bronze impeller & internal parts, make as approved by ISO/CFO for fire duty, complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation, antivibration paid , capable of discharging 2850 lt/min against 90 mtr. head against all losses complete. The scope shall also include electrical TEFC motor, operated on 3-ph, 440-V, 50 Hz, 1500 RPM Syn. speed with ‘B’ class winding, make as approved by LFA. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating etc. complete. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS . System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller and BMS. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Pump - Motor : Discharge : 2850 LPM, Head 90 mtr

2

1330384

665192

... More
Supplying & installing completely testing & commissioning centrifugal main fire pump (diesel driven)with cast iron casing & bronze or phosphor bronze internal parts, make as approved by ISO/CFO for fire duty, complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation,antivibration paid , capable of discharging 2850 lt/min against 90 mtr. head against all losses complete with suitable diesel engine of speed matching the pump speed ,auto start facility with battery & battery charger, necessary wiring, fuel tank ,exhaust system, foundation gauges & wired for automatic start of the water pump on drop of pressure in the hydrant and sprinkler system. The pump should confirm to LFA / SEB & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Pumping System shall be capable to communicate with BMS . System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller and BMS. Indication of on-off status parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Pump - Diesel Engine : Discharge : 2850 LPM, Head 90 mtr

1

964252

964252

... More
Supplying, installing, testing and commissioning of Vetrical Centrifugal jockey pump-motor with discharge 180 lpm against 90 mtr. head with 3 phase, 415 V, 50 Hz motor having 2900 RPM, complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation,antivibration paid , as per site conditions and instructions of site engineer-in-charge including proper fixing, The electrical motor for the pump should comply as per Specification. The scope shall also include necessary coupling, coupling guard, base frame, foundation bolts, RCC foundation, etc. complete. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS . System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller and BMS. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Pump - Motor : Discharge : 180 LPM, Head : 90 mtr.

2

426198

213099

... More
SITC of precharged MSEP air vessel (size 600mm dia x 2000 mm height) with adequate pressure switches with valves to operate as per operating sequence including 25 mm drain valve, air release valve with stop cock on top, 25 mm inlet with isolation valve & the vessel shall be painted inside & outside. The tank shall be fabricated from 8 mm thick MS plate with painting Air Vessel : 600 mm dia x 2000 mm h

2

146160

73080

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required. 200 mm dia.

1

30819

30819.5

... More
150 mm dia.

4

74526

18631.62

... More
100 mm dia.

4

45944

11486.16

... More
80 mm dia.

1

7991

7991.34

... More
50 mm dia.

1

5984

5984.76

... More
40 mm dia.

2

11969

5984.76

... More
Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304' sheet with.3 mm dia holes with stainless steel flange. 200 mm dia

2

46750

23375.12

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

5

7992

1598.48

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.

48

64503

1343.83

... More
Supply, installation, testing & commissioning of metallic SS 304 bellows on discharge side of pump conforming to EJMA with all hardwares, companion flanges & gaskets, etc. Size : 200 mm

3

54147

18049

... More
Size : 150 mm

9

129492

14388

... More
Size : 100 mm

8

92056

11507

... More
Size : 80 mm

12

126000

10500

... More
Size : 65 mm

6

57000

9500

... More
Size : 50 mm

5

45560

9112

... More
Size : 40 mm

7

58401

8343

... More
Supplying and fixing of fire brigade connection of casliron body with gun-metai rnale instantaneous inlet couplings complete wiih cap and chain as reqd. for suitable dia MS pipe c onnection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe

3

20956

6985.4

... More
Supplying and fixing of fire brigade connection of casliron body with gun-metai rnale instantaneous inlet couplings complete wiih cap and chain as reqd. for suitable dia MS pipe c onnection conforming to IS 904 as required : 4 way-150 mm dia M.S. Pipe

1

14651

14651.32

... More
SITC of fire brigade draw out connection with 100 mm MS suction pipe and 100 mm dia Cast iron foot valve. The scope shall also include required valves, piping, M.S cabinet as required.

1

13850

13850

... More
SITC of electronic type water level indicator with LED panel, with probe & all control wiring to operate the system automatic/ manual & shall prevent the pump from dry running .

1

47790

47790

... More
MCC for Fire Pumps: Design, manufacture, supply ,installation, testing and commissioning of following MCC panels suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system.the panel should be indoor, free standing, floor mounting, sheet metal clad, Cubicle, dead front, dust and vermin proof conforming to IP-55 enclosure, compartmentalized design fabricated out of 14 SWG sheet steel complete with Al busbars, separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement, adequate size cable alley, painting, earthing numbering, damper plate etc. as required as per specifications and drawings. The panel shall withstand a fault level of 25 KA unless specified otherwise. (Cost of wiring with pressure switches/ switching on and switching off the pumps locally and remotely as per the drawing and as per local CFO requirement) NOTE : 1). Separate neutral link to be provided wherever TP MCCB are used. 2). All MCCB shall have breaking capacity of 25 KA unless otherwise specified. 3). Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price. 4). following provisions to be made in the fire panel: 5). Audio visual alarm and indications having disconnect/reset facilities with a range of 1/2 Km. The indication shall come on when electrical driven pump set fails to start on pressure drop 6). Facility for more selections i.e. auto or manual and local remote as per SLD. 7). Protection failure and control cabling. 8). Interlocking with Diesel engine pump / D.G. set 9). The above requirement is general, in addition to that the vendor shall provide all the component/system/work for the proper operation of fire pumps as per fire rules and regulations Incomer : As per SLD Outgoing : As per SLD

1

408000

408000

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

2

14532

7266.3

... More
S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required

50

2703

54.06

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench/ pipe of following size of cables. 150 sq. mm 3.5 Core Cable

60

85160

1419.34

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall with necessary clamps or in existing trench/ pipe at road crossing or floor of following size of cable.10 Sq.mm 3 Core cable( for jockkey pmp)

30

28938

964.6

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench/ pipe at road crossing or floor of following size of cable. 2.5 Sq.mm 3 Core cable

1189

758724

638.12

... More
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall with necessary clamps or in existing trench/ pipe at road crossing or floor of following size of cable. 4 Sq.mm 3 Core cable

50

32860

657.2

... More
supplying and making end termination with brass compression grand and aluminium lugs for following size of pVC insulated and pIIC streathed / XLPE aluminium co{ductor cable of 1.1 KV grade as required. 3 & 1/2 core 150 Sq. mm

4

2353

588.3

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3/4 X 10 sq. mm (22mm)

4

2512

628

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 2 to 4 core 2.5/4 Sq. mm

24

9720

405

... More
Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 MM

200

30740

153.7

... More
32 MM

200

39008

195.04

... More
Providing, fixing, testing & commissioning of 15 mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Pendent Sprinkler Standard Coverage 5.6 K-factor

3304

1695084

513.04

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 68 degree rated brass pendent sprinklers having 15 mm NPT connection with all accessories: 3 mm glass bulb 68 deg. Pendent Sprinkler Extended Coverage 5.6 K-factor

1

935

935

... More
Providing, fixing, testing & commissioning of 15 mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Concealed Pendent Sprinkler Standard Coverage 5.6 K-factor

1

1480

1480.82

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 68 degree rated brass pendent sprinklers having 15 mm NPT connection with all accessories: 3 mm glass bulb 68 deg. Concealed Pendent Sprinkler Extended Coverage 5.6 K-factor

1

2090

2090

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 57 degree rated brass concealed pendent sprinklers having 15 mm NPT connection with all accessories: 3 mm glass bulb 68 deg. Pendent Sprinkler Standard Coverage 11.2 K-factor

1

1820

1820

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 57 degree rated brass concealed pendent sprinklers having 15 mm NPT connection with all accessories: 3 mm glass bulb 68 deg. Pendent Sprinkler Extended Coverage 11.2 K-factor

1

2185

2185

... More
Providing, fixing, testing & commissioning of 15 mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler Standard Coverage 5.6 K-factor

924

474048

513.04

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 68 degree rated brass upright sprinklers having 15 mm NPT connection with all accessories: 3 mm glass bulb 68 deg. Upright Sprinkler Extended Coverage 5.6 K-factor

1

935

935

... More
Providing, fixing, testing & commissioning of 15 mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Horizontal side wall sprinkler Standard Coverage 5.6 K-factor

1

613

613.74

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 68 degree rated brass side wall sprinklers Standard Coverage having 15 mm NPT connection with all accessories for ramp etc. 3 mm glass bulb 68 deg. Side Wall Sprinkler Extended Coverage 5.6 K-factor

1

870

870

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 93 degree rated for Kitchen brass pendent sprinklers having 15 mm NPT connection with all accessories for ramp etc. 3 mm glass bulb 93 degree rated for Kitchen Pendent Sprinkler 5.6 K-factor

1

1100

1100

... More
SITC of 3 mm quick response glass bulb type UL approved and FM approved 93 degree rated for Kitchen brass Upright sprinklers having 15 mm NPT connection with all accessories for ramp etc. 3 mm glass bulb 93 degree rated for Kitchen upright Sprinkler 5.6 K-factor

1

1100

1100

... More
SITC of test & drain assembly with all piping & sight glass including 25mm diameter 2 nos drain valve, union, required 25mm diameter drain pipe etc. complete.

41

639600

15600

... More
Providing & fixing flow switch in following sizes pipe including connection etc as required. Header size : 150 mm

15

141017

9401.14

... More
Providing & fixing flow switch in following sizes pipe including connection etc as required. Header size : 100 mm

10

78037

7803.72

... More
Providing & fixing flow switch in following sizes pipe including connection etc as required. Header size : 80 mm

1

7362

7362

... More
Providing & fixing flow switch in following sizes pipe including connection etc as required. Header size : 65 mm

15

110430

7362

... More
Providing & fixing flow switch in following sizes pipe including connection etc as required. Header size : 50 mm

1

7362

7362

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 MM

1653

2698357

1632.4

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500 MM

1653

3145163

1902.7

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

3304

724963

219.42

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/ bronze working parts comprising of water motor alarm. bronze seat clapper, clapper arm and hydrautically driven mechanical gong bell to sound continuous alarm when the wet riser/ sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate. gasket etc of follwing sizes as required: 150 mm dia

7

355403

50771.88

... More
Charges for Liasoning with CFO and getting all approvals and permissions and NOC 's required for fire fighting at various stages and after completion of the project including All official payments. (All official and receipted payments would be submitted and Re-imbursed)

1

300000

300000

... More
Hi Wall Type AC Unit : Supply, installation, testing and commissioning of following minimum capacity VRV/ VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
1.0 TR Hi wall Type AC Unit

2

41894

20947.01

... More
1.65 TR Hi wall Type AC Unit

1

23122

23122.52

... More
4 Way Cassette Type AC Unit : Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
1.0 TR Four way Cassette Type AC Unit

34

1053366

30981.37

... More
1.2 TR Four way Cassette Type AC Unit

51

1599084

31354.59

... More
1.6 TR Four way Cassette Type AC Unit

12

385390

32115.91

... More
2.0 TR Four way Cassette Type AC Unit

5

163753

32750.7

... More
2.4 TR Four way Cassette Type AC Unit

1

33443

33443.98

... More
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.

-

-

-

... More
4.0 TR Mid static Ductable Unit

2

103631

51815.67

... More
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from Engineer In-charge).

-

-

-

... More
10 HP

2

349081

174540.7

... More
14 HP

3

733070

244356.97

... More
16 HP

3

837795

279265.11

... More
18 HP

1

314173

314173.25

... More
20 HP

1

349081

349081.39

... More
VRF System Remote Controller: Supply, Installation, Testing and Commissioning of Corded remotes with LCD Display for VRF indoor units (All IDUs except High Wall Units)

105

472500

4500

... More
VRF System Remote Controller: Supply, Installation, Testing and Commissioning of Cordless remotes for VRF indoor units (For Hi Wall Type IDUs)

3

15000

5000

... More
Supply, Installation, testing & Commissioning of Central Controller for entire VRV system , the scope includes the control wiring and conducting of the same in a lot. The controller shall be programmed for soft integration with the building BMS system. Also, Controller have Tenant Management/ Monitoring facility to Generate report of Power consumption of each indoor units.

1

245000

245000

... More
Branch Distribution refrigerant Pipe joints with precase insulation : Supply of Imported Branch Distribution Joints for VRF system. ( The quantity shown here is indicative - in case the quantity requirement is differ based on the system selection for the specific product the revised quantity is required to quoted here)

110

495000

4500

... More
Refrigeration Piping & First Charge of Refrigerant For VRF System : Supply, Installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with Class O tubular insulation closed cell elastometric nitrile rubber having factory bonded GC bonding of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required. All the exposed pipe insulation have an additional protective cover of UV resistant paint suitably covered with glass cloth as per specification:

-

-

-

... More
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

180

46891

260.51

... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

147

51736

351.95

... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

200

99099

495.5

... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation

235

146926

625.22

... More
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

269.5

202597

751.75

... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

257.5

236836

919.76

... More
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

80

86935

1086.69

... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation

115

135485

1178.14

... More
31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

85

105745

1244.06

... More
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

85

111168

1307.86

... More
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

115

154683

1345.08

... More
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation

100

139186

1391.86

... More
In case any part installation, the unit rate shall be calculated on per ODU HP basis. NOTE:- The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by: (1) Using One End Expanded Tubes. (2) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (3) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (4) The makes of tube fittings shall be same as that of tubes. (5) The thickness of fittings used shall be same as that of the pipe.

-

-

-

... More
Refrigerant Gas First Charge

-

-

-

... More
10 HP

2

24000

12000

... More
14 HP

3

48000

16000

... More
16 HP

3

54000

18000

... More
18 HP

1

20000

20000

... More
20 HP

1

22000

22000

... More
Power & Communication Cabling For VRF System

-

-

-

... More
Power Cabling to individual Outdoor units with PVC conduits. ( From Power Panel to VRF ODU )

1190

416500

350

... More
Communication Cable between Outdoor Units & Indoor Units with PVC conduits

1065

186375

175

... More
DRAIN PIPING: Providing and Fixing Hard CPVC drain water piping with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation with ASTM E84 25/50 rated - where Flame Spread Index is 25 and Smoke Developed Index is 50, UL94(VO,HB) Passed ,GRIHA(V.3 criterion:14; V.2015 criterion: 8) certified and ASHRAE 90.1, NFPA 90A/NFPA 90B standards compliant Anti Microbial Closed Cell Nitrile Rubber with company bonded GC sheet of 7 mils/200 gsm having K value of 0.036 w/m.k at 24 Deg C with temp range of (-)50 to 105 Deg C. Water Vapor Permeability to be minimum 0.05 Perm-inch without any external barrier with protection against harmful Microbes as per ASTM G-21/UL-181/ASTME-2180-18 with Antimicrobial & Antiviral additive to be EPA approved for use in Drain piping. The material should have JIS Z 2801 Standard for Anti Viral Properties. The insulation material shall and have ozone resistance as per ASTM D 1149 . Adhesives to be GRIHA/IGBC compliant. Installation should be as per manufacturers SOP.

-

-

-

... More
25 mm NB

350

175000

500

... More
32 mm NB

230

138000

600

... More
40 mm NB

145

101500

700

... More
DX Type Hi Wall Type Split AC Unit : Supplying, Fitting & Fixing of A.C. with heating & Cooling facility including supply of all necessary accessories as required for installation of air conditioner (AC). 1.5 ton capacity

10

989230

98923

... More
Cabinet Type Centrifugal Exhaust Air Fans : Supply, Installation, testing & Commissioning of Cabinet type Centrifugal Fans for Exhaust Air System completewith MS zinc sprayed/ powder coated SISW Forward Curved blower, fan assembly shall be AMCA certified (AMCA certification required for Air Performance & Sound) & totally enclosed, fan-cooled, provided with class F insulation of approved make, Fan shall be provided with TEFC Sq.cage, direct driven F' Class induction motor with minimum IP-55 protection. Motor shall be suitable for 220 ± 5% volts, Single phase, 50 cycles OR 415+/-6% V, 50 hz, 3 phase electric supply As per Ventilation Equipment Schedule. The motor (Eff1 Class-Motor must be VFD Compatible) Max. noise level shall be 56 dBA at 1.5 meter in hemispherical reverberant room condition. The complete fan assembly shall be CE Certified in accordance with EN-12101-3:2015 (Vendor shall submit the certifications for below listed fans). The Fan units shall be designed as per the criteria mentioned in the specifications and selected so as to operate in the best efficiency zone; the units shall be statically and dynamically balanced. Necessary starter shall be in scope of HVAC Contract. Power cable will be available up to starter panel. The controller will be BMS compatible with all required open protocol and required licence softares.

-

-

-

... More
2000 CFM / 30 mm ESP

1

50000

50000

... More
2200 CFM / 30 mm ESP

1

50000

50000

... More
2500 CFM / 30 mm ESP

3

150000

50000

... More
3000 CFM / 40 mm ESP

3

180000

60000

... More
3200 CFM / 40 mm ESP

1

60000

60000

... More
3600 CFM / 40 mm ESP

1

65000

65000

... More
4000 CFM / 40 mm ESP

2

130000

65000

... More
5500 CFM / 40 mm ESP

1

75000

75000

... More
Supply, Installation, testing & Commissioning of Floor Mounted Cabinet Type Centrifugal Fresh Air Fan Filter Unit complete with MS zinc sprayed/ powder coated DIDW Centrifugal Impeller Fan with motor for maximum speed duty point of Specified CFM and Static pressure as specified , complete with drive package comprising of V belts and Grooved pulley pair keyed to motor and fan shafts. Fan shall be provided with TEFC Sq.cage, direct driven F' Class induction motor with minimum IP-55 protection Motor shall be suitable for 220 ± 5% volts, single phase, 50 cycles OR 415+/-6% V, 50 hz, 3 phase electric supply As per Ventilation Equipment Schedule. The motor (Eff1 Class-Motor must be VFD Compatible ) Max. noise level shall be 56 dBA at 1.5 meter in hemispherical reverberant room condition. The fan shall have easily washable 20 micron fresh air filter. The Fan units shall be designed as per the criteria mentioned in the specifications and selected so as to operate in the best efficiency zone; the units shall be statically and dynamically balanced. Necessary starter shall be in scope of HVAC Contract. Power cable will be available up to starter panel. The controller will be BMS compatible with all required open protocol and required licence softares.

-

-

-

... More
1600 CFM / 40 mm ESP

1

60000

60000

... More
1800 CFM / 40 mm ESP

1

60000

60000

... More
2500 CFM / 40 mm ESP

2

140000

70000

... More
2800 CFM / 40 mm ESP

2

140000

70000

... More
3000 CFM / 40 mm ESP

1

80000

80000

... More
3500 CFM / 40 mm ESP

2

170000

85000

... More
4000 CFM / 40 mm ESP

2

170000

85000

... More
4200 CFM / 40 mm ESP

1

85000

85000

... More
4500 CFM / 40 mm ESP

1

90000

90000

... More
5500 CFM / 40 mm ESP

1

95000

95000

... More
SITC of WALL MOUNTED PROPELLER EXHAUST FAN WITH GRAVITY LOUVERS

-

-

-

... More
100 CFM

9

13500

1500

... More
150 CFM

1

2000

2000

... More
500 CFM

4

14000

3500

... More
1000 CFM

5

25000

5000

... More
SITC of an in-line Ozonator, capable of generating 250-300 mg/hr of Ozone and suitable for treating of exhaust air, to be fitted in the STP exhaust duct for removal of Odour from the air being released in the air. Commercial Deodorizer & Air Purifier (Ozone Generator) suitable to discharge ozone in ducts, producing high volume of ozone via corona discharge method. The unit must have separate chambers for electrical components & ozone generation, with isolation. Air intake to the unit shall be thru Hydrophobic pre filter, to contain moisture from getting in to the unit. Unit must be provided with 2 set of fans, one for pre/ after cooling of electrical components & one for ozone injection in to the duct. The ozone generator must be provided with inbuilt, factory fitted air flow switch for unit on/off operation as per the air flow in the exhaust ducts. Exhaiust Air Quantities as under. Ozone injection shall be maximum 2 Grams/Hr per 1000 CMH & contact time of Ozone with air stream should be minimum 1 Second. (However the vendor shall select the equipment to ensure designs parameters are met.) Ozone Generation - Corona Discharge method Pre Filter - Hydropobic for air inlet Ozone Plate Life - minimum 3000 hrs Power Supply - 230 V/ SP/ 50 Hz

1

530000

530000

... More
Supply, installation, balancing & commissioning of Factory Fabricated GSS sheet metal rectangular/ round ducts, complete with neoprene rubber gasket, elbows, splitters dampers, vanes, hangers, supports etc as per approved drawings & specifications of following sheet thickness complete as required.

-

-

-

... More
Thickness 0.63 mm sheet (750 mm & Below)

3315

3806826

1148.36

... More
Thickness 0.8 mm sheet (750 mm to 1500 mm)

191

256503

1342.95

... More
Thickness 1.00 mm sheet (1501 mm to 2250 mm)

15

20431

1362.09

... More
Supply Installation Testing And Commissioning of Diffusers/ Grilles As Per Following Schedule

-

-

-

... More
Supply & Fixing of Powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

7.6

73578

9681.35

... More
Supply & Fixing of Powder coated extruded aluminium Return Air Grills with Louvers but without volume control dampers completed as required.

7.8

49016

6284.1

... More
Supply, Installation, Testing, Commissioning of GI Powder Coated Duct Dampers

-

-

-

... More
Supply, installation, testing and commissioning of Gl volume control sqm duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

4.5

33714

7492.01

... More
Flexible Connections : Supply, installation, testing and commissioning of Flexible canvass connections to isolate vibrations produced by Air handling units, fans and other air moving equipments when these are to be connected to air ducts where ever specified. Canvass connections shall be of the same cross-sectional area as the mating fan inlet/ outlet or duct section. Flexible Duct connector shall be tested and certified in accordance with BS 476 part 7 for class 1 and NFPA-701 from NABL accredited lab

27

94500

3500

... More
Supply & installation of Flexible connections between Duct and Cassette connection. Connections shall be of the same cross-sectional area as the mating fan inlet/ outlet or duct section. Flexible Duct connector shall be tested and certified in accordance with BS 476 part 7 for class 1 and NFPA -701 from NABL accredited lab. Size should be as per inlet connection of Cassette.

103

128750

1250

... More
Duct Thermal Insulation : Providing & Fixing Duct thermal insulation with Closed cell Elastomeric Foam made from EPDM having density 40-60 kg/m3 & thickness of 13 mm for Supply Air & Return air duct ( Ducts in the loose return air path ) Duct & 19 mm for SA-RA Duct ( Duct routed in non conditioned spaces ) as per the specifications . Material shall have fire class A (Flame spread:20 & Smoke developed: 150) in accordance with ASTM E-84 and flammability class V-0 as per UL 94 / Or Shall comply Class O as per BS part 6 for fire propagation test and class 1 as per BS 476 part 7 for surface spread of flame test. Thermal Conductivity is 0.035 w/m.k at 24°C mean temperature and having µ value ≥ 7000 without any covering. Material shall be Anti-fungal & Anti-Bacterial in accordance with UL181 and ASTM E2180 respectively.FSK tapes shall be applied at joint.

-

-

-

... More
19 mm

63

47250

750

... More
25 mm

5

4500

900

... More
Duct Acoustic Insulation : Providing and fixing acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommended thickness of 15 mm. Absorption coefficient value of Insulation material shall be 0.90 for the 2000 Hz frequency band in accordance to IS:8225/ISO:354/ASTM 423C. Material shall have fire class 1 as per BS 476 , part 7. Material Shall be EPA approved and Anti-Fungal & Anti- Bacterial in accordance with ASTM G21 & ASTM E 2180 respectively. It shall be fixed inside of the duct with the help of adhesive as per the specifications given.FSK tape shall be applied at joints.

-

-

-

... More
15 mm

10

7500

750

... More
10 mm

110

60500

550

... More
Insulation Protecting Cover (For Duct / Refrigerant pipe Insulation within the Building) Insulation shall be covered with self-adhesive fibber glass cloth which is Acrylic based woven fiberglass fabric made from E glass(self adhesive) and has total thickness 0.19±0.02 mm. It shall have GSM 280 (±5%). It shall be UV protective. Colour As per Design - Red / Blue / Green / Black / Gray / other as per requirement.

10

1500

150

... More
Insulation Protecting Cover (For Duct / Refrigerant pipe Insulation Outside the Building, Shaft & Service Area/Mezz. Floor) Insulation shall be covered with self bonded olefin sheet which is high density polyethylene fibber cloth with backing of moisture control metal foil and minimum thickness 150µm. It shall have GSM 67.5 (±5%). Material shall have minimum reflectivity 0.90. It shall be UV protective. (White Colour)

27

6750

250

... More
Vibration Absorbent spring supports for AHUs/ Fan units ( 4 to 8 Support for each )

27

270000

10000

... More
VRF ODU Engineered floor support ( 4 to 6 Support for each ODU )

10

30000

3000

... More
Engineered Rubber Support Pad for Split AC Out Foor Unit

10

25000

2500

... More
MS Welded Structure (Supply and erection of M.S. angle stand with synthetic epoxy paint )

510

63750

125

... More
Minor civil work

3

225000

75000

... More
Zari Work for drain piping , civil hole making etc.

180

81000

450

... More
Core Cut Up to 100 mm Dia

12

18000

1500

... More
SPECIAL NEED FOR DISABLED TOILET: Providing and Fixing EWC wall hung, Wash basin, Grab bar, Hinged rail & special faucet with spachula including seat cover, and flush valve, fittings, nuts, bolts and gasket etc complete for disabled toilet of approved make and conforming to IS Standards. Wash basin with one pair mounting brackets, Waste coupling 32 mm size full thread with 80 mm heightJaquar make with 10 years warranty: Chrome plated, Bottle trap Jaquar make with 7 years warranty: Chrome plated etc., EWC S Trap & Cistern complete with fittings & seat cover, one no. hinged rail 750 mm & Two nos of grab rails 600 mm ,etc. complete. Refer following product wise details, EWC : 710 x 370 x 770 mm Cat. No. S1013200 One piece EWC S trap 300 mm with Cat. No. B1520118 Soft close seat cover Wash Basin : Cat. No. S2040159 CRANE Wall hung wash basin 665 x 545 x 190 mm. Cat. No. F9030453 Single lever clinical faucet Cat. No. B2210106 Wall mounted Grab Bar 600 mm Long Cat. No. B2210108 wall mounted Hinged Hand Rail 750 x 100 Make : Cera- Cruset Set

22

1414820

64310

... More
WATER CLOSET: Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend as per specifications; glazed vitreous/ coloured European Water Closet with Conceal cistern (IS-2326), with grouting the CI chair in side the floor/wall, rubber gaskets, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern on WC., Ragbolt, Gasket Fitiiing and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; hole in walls/slab/beam and making good etc. compete the job. EWC-P with PP Soft close Seat cover, Cistern with cistern fittings: W.C Wall Hung : Jaquar, Model No. : SLS-WHT-6953BIPPSM Concealed Cistern : Jaquar, Model No. : JCS-WHT-2400FS Flush Plate : Jaquar, Model No. : JCP-CHR-292415

133

4146142

31174

... More
WASH BASIN: Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single piece of 15 mm C.P. brass pillar taps

154

418867

2719.92

... More
PILLAR COCK: Providing and fixing in position 15 mm C.P. brass Pillar cock of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. PILLAR COCK : Jaquar , Model No. FLR-5015

154

389774

2531

... More
BOTTLE TRAP: Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer In-charge.

187

178754

955.91

... More
URINAL: Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer In-charge.

84.7

605573

7149.63

... More
URINAL PARTITION: Providing and fixing Rectangular shaped urinal partition with frosted glass approx. size 900 MM (H) X 450 MM (W) having 10mm of glass thickness, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer In-charge.

57.2

434319

7593

... More
KITCHEN SINK (STAINLESS STEEL): Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per ls:13983 with C.I. brackets and stainless steel plug 40 mm, including painting Of fittings and brackets, cutting and making gcod the walls wherever required: kitchen sink with drain board 510x1040 mm bowl depth 250 mm

11

65277

5934.28

... More
SINK COCK: Providing and fixing in position 15 mm C.P. brass sink cock of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. SINK COCK : Jaquar , Model No. FLR-5357SD

11

39523

3593

... More
ANGLE VALVE: Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (a) 15mm dia nominal bore.

237.6

140973

593.32

... More
BRAIDED HOSE COPPER PIPE: Providing and fixing C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. BRAIDED HOSE Copper Pipe : Jaquar, Model no. ALD-803AB

237.6

81972

345

... More
BIB COCK (Long body bib cock with wall flange): Providing and fixing C.P. brass long nose bib cock of approved quality confirming to IS standards and weighing not less than 810 gms. (a) 15mm nominal bore.

12.1

10061

831.5

... More
TWO WAY BIB COCK: Providing and Fixing in position CP brass 2 Way bib cock of approved make and quality, conforming to IS standards and weighin not less that 810 grams, and as approved and directed by the Engineer In-charge. TWO WAY BIB COCK : Jaquar, Model no. FLR-5041N

155.1

453357

2923

... More
HEALTH FAUCET: Providing and fixing 8 mm dia. C.P/ S.S Jet with flexible tube up to 1.2 metre long with S.S. triangular plate to European type W.C. Of quality and make as approved by Engineer In-charge. HEALTH FAUCET : Jaquar, Model no. ALD-573

155.1

312991

2018

... More
TOILET PAPER HOLDER: Providing and fixing toilet paper holder : C.P. brass

155.1

124700

804

... More
TOWEL RING: Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

176

54457

309.42

... More
LIQUID SOAP CONTAINER: Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

176

30691

174.38

... More
ROBE HOOK: Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. ROBE HOOK: Jaquar, Model no. CAN-1191N

155.1

71811

463

... More
Electrical hand dryer, fully automatic type, cover shall be fabricated in extra heavy duty 18 gauge type 304 SS with exposed surfaces satin finished, the unit shall deliver not less than 30 l/sec of hot air and electrical rating shall be 230 V/ 1 phase. HAND DRYER : Jaquar, Model no. PTD-SAP-DT0106CS

44

404184

9186

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

176

209410

1189.83

... More
SOAP DISH: Providing & fixing Soap Dish of best quality including fixed into wall with C.P. Brass screws and rawlplugs etc. complete including cutting and making good the wall where required. SOAP DISH : Jaquar, Model No.: ACN-1131N

176

183744

1044

... More
Providing fixing, testing and commissioning 160 mm dia. SWR PVC PIPE TYPE-B (6Kg/cm2.) with all the engineered support as per detail technical specification self fit pipe conforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. jointing with PVC Adhesive joints including holes in walls and making good the same. (Birla/ Supreme/ Ashirvad/ Astral Makes)

2437.05

2735271

1122.37

... More
Providing fixing, testing and commissioning 110 mm dia. SWR PVC PIPE TYPE-B(6Kg/cm2.) with all the engineered support as per detail technical specification self fit pipe conforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. jointing with PVC Adhesive joints including holes in walls and making good the same. (Birla/Supreme/ Ashirvad/ Astral Makes)

1755.05

1104066

629.08

... More
Providing fixing, testing and commissioning 75 mm dia. SWR PVC PIPE TYPE-B(6Kg/cm2.) with all the engineered support as per detail technical specification self fit pipe conforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. jointing with PVC Adhesive joints including holes in walls and making good the same. (Birla/Supreme/ Ashirvad/ Astral Makes)

286

118481

414.27

... More
Providing, fixing and jointing 50 mm nominal bore Unplasticized rigid PVC agricultur pipes conforming to IS: 4985 (working pressure 6 kg/Sqcm) with all the engineered support as per detail technical specification including all fittings such as bends, clamps, cowls, supports etc. cost of cutting holes and making good the walls all complete. (Birla/Supreme/ Ashirvad/ Astral Makes)

78.1

17056

218.39

... More
Providing, fixing and jointing 40 mm nominal bore Unplasticized rigid PVC agricultur pipes conforming to IS: 4985 (working pressure 6 kg/Sqcm) with all the engineered support as per detail technical specification including all fittings such as bends, clamps, cowls, supports etc. cost of cutting holes and making good the walls all complete. (Birla/Supreme/ Ashirvad/ Astral Makes)

113.3

20243

178.67

... More
Providing & fixing PVC SWR TYPE B P TRAP of 110 X 110 mm diameter with Height riser/ necessary 110MM Diameter of distance piece for urinal drain connection with floor clean out square cut 150mm- Satin of approved Make, making necessary slab/ wall/ beam holes and cutting walls, etc. complete.

304

153082

503.56

... More
Providing and fixing stainless steel (SS304) Perforated grating 'of 18 gauge thick, with 'circular perforation including Cockroach trap of 'approved pattern over CI/PVC 'traps. The grating shall be of size 153mm x 153mm or circular of 100mm dia '(as directed) and shall 'be set in cement, sand mortar 1:3 etc. complete. (Euronics/ Chilly Makes) MAKE: CHILLY MODEL : CCT-SSGFC-153 Matt Finish

271

500374

1846.4

... More
Providing and fixing stainless steel (SS304) Tile Insert grating 'of 18 gauge thick, with 'circular / Rectangular perforation including Cockroach trap of 'approved pattern over CI/PVC 'traps. The grating shall be of size 152mm x 152mm or circular of 100mm dia '(as directed) and shall 'be set in cement, sand mortar 1:3 etc. complete. (Euronics/ Chilly Makes) MAKE: CHILLY MODEL : CCTL-SMR-152 Matt Finish

32

180294

5634.2

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size p type with Sewer bricks conforming to IS : 4885

12

38967

3247.32

... More
Providing & fixing 110mm OD. floor clean out square cut of approved make with making necessary slab/ wall/ beam holes and cutting walls, etc. complete. (Birla/Supreme/ Ashirvad/ Astral Makes)

153

28051

183.34

... More
Providing & fixing 75 mm dia PVC Cowl on PVC ventilating pipes and verticals for soil and waste Pipes & Rain water pipes at top level/ terrace level, as specified and required, etc. complete. Astral or Equivalent.

9

479

53.32

... More
Providing & fixing 110 mm dia PVC Cowl on PVC ventilating pipes and verticals for soil and waste Pipes & Rain water pipes at top level/ terrace level, as specified and required, etc. complete. Astral or Equivalent.

6

440

73.38

... More
Providing & fixing 160 mm dia PVC Cowl on PVC ventilating pipes and verticals for soil and waste Pipes & Rain water pipes at top level/ terrace level, as specified and required, etc. complete. Astral or Equivalent.

17

1989

117.04

... More
Supply, Installation, Testing and Commissioning of 75 mm dia. Air Admittance Valve.

18

73558

4086.56

... More
Supply, Installation, Testing and Commissioning of 110 mm dia. Air Admittance Valve.

31

126683

4086.56

... More
Constructing brick masonry Manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)

10

139185

13918.6

... More
Extra for depth for Manholes: (A) Size 90x80 cm

8.8

102422

11638.88

... More
Constructing brick masonry Road Gully Chamber 50 x 45 x 60 cm with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design.

47

327037

6958.24

... More
Constructing brick masonry chamber for underground C.I. Inspection Chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets with common burnt clay F.P.S. (non- modular) bricks of class designation 7.5

4

32602

8150.5

... More
Extra for depth beyond 45 cm of brick masonry chamber: For 500X700 mm size with common burnt clay F.P.S. (non- modular) bricks of class designation 7.5

4.4

26914

6117

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer In-charge. Internal work- Exposed on wall- 25 mm nominal diameter pipes

34.65

8547

246.69

... More
32 mm nominal diameter pipes

52.8

32730

619.9

... More
40 mm nominal diameter pipes

107.8

79548

737.93

... More
50 mm nominal diameter pipes

260.7

53777

206.28

... More
65 mm nominal diameter pipes

70.4

130900

1859.38

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer In-charge. Concealed work, including cutting chases and making good the walls etc.- 15 mm nominal outer diameter pipes

20.9

8422

402.99

... More
20 mm nominal outer diameter pipes

498.3

244257

490.18

... More
25 mm nominal outer diameter pipes

179.3

113245

631.6

... More
32 mm nominal outer diameter pipes

205.7

178476

867.65

... More
40 mm nominal diameter pipes

59.4

65867

1108.88

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 m nominal bore

8

4304

538.03

... More
20 mm nominal bore

7

3833

547.6

... More
32 mm nominal bore

20

12568

628.41

... More
40 mm nominal bore

35

25641

732.61

... More
50 mm nominal bore

7

6557

936.77

... More
Supply, Installation, Testing and Commissioning of 25 mm dia. Air Release Valve (ARV).

15

18321

1221.44

... More
Providing and fixing Nitrile Rubber Insulation with UV protected CLASS-O ALUPET FOIL over insulation pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (INTERNAL WORK : INSIDE THE WALL/ COVERED INSTALLATION/ SUNK SLAB) (EXPOSED WORK : VERTICAL PIPE/ TERRACE ROUTING PIPE) 25 mm dia. (13MM Thick)

34.65

4925

142.16

... More
32 mm dia. (13MM Thick)

52.8

7973

151.01

... More
40 mm dia. (13MM Thick)

107.8

18822

174.61

... More
50 mm dia. (13MM Thick)

260.7

55211

211.78

... More
65 mm dia.(13MM Thick)

70.4

19602

278.45

... More
Supply , Installation, Testing and Comissioning of ISO certified company made self contained Drinking Water Cooler with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray,minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Cooling capacity 80 Ltr/ Hr and Storage capacity 120 Ltrs

28

1694000

60500

... More
Supplying & erecting 5 stage single Reverse Osmosis water purification system with M.S. powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 Osg inline type post carbon filter auto low & high pressure switches with following size of storage tank & LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [A] 25 Ltr / Hr output

28

1184400

42300

... More
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.

44

42931

975.72

... More
Providing & fixing PVC SWR TYPE B P Trap of 110 X 110 mm diameter with Height riser/ necessary 110MM Diameter of distance piece for wash basin/ sink drain connection with cockroach trap - square flat cut, Satin-matt finish - 150mm x 150mm of approved Make, making necessary slab/ wall/ beam holes and cutting walls, etc. complete.

1

1520

1520

... More
Providing and fixing stainless steel (SS304) Perforated grating 'of 18 gauge thick, with 'circular perforation including Cockroach trap of 'approved pattern over CI/PVC 'traps. The grating shall be of size 150mm x 150mm or circular of 150mm dia '(as directed) and shall 'be set in cement, sand mortar 1:3 etc. complete. (Euronics/ Chilly Makes)

1

650

650

... More
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type.

17

53649

3155.87

... More
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. (B) 150mm

316.8

178869

564.61

... More
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. (C) 250mm

356.4

327042

917.63

... More
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. (D) 300mm

1531.2

1566256

1022.9

... More
Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

1900

860635

452.97

... More
Earthwork in excavation by Mechanical means up to a depth of 2-4m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

1900

1048520

551.85

... More
Earthwork in excavation by Mechanical means up to a depth of 4-6m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

40

26029

650.74

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering. ii) Earth Filling (For Marshy Soil)

3606

3973289

1101.86

... More
Sand filling in plinth in layers not exceeding 150 mm thick including breaking Of clods, consolidating by ramming and watering complete as directed (maximum depth 45 cm)

633

1271427

2008.57

... More
PCC: Providing & laying Plain cement concrete works in foundation bed for footing steps, walls, brick works etc. below plinth level as directed and specified including shuttering, centring, formwork, dewatering if necessary, and curing complete. M10 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)

240

1939714

8082.14

... More
Constructing brick masonry circular type manhole 0.91 in internal dia. at bottom and 0.56 in dia. at top in cement mortar 1 :4 (1 cement: 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1 :3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a I loating coat of neat cement, all complete as per standard design: 0.91 in deep with s.F.F}.C. cover and frame (heavy duty, HD- 20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.

7

104873

14981.9

... More
Constructing brick masonry circular manhole 1.22 in internal dia. at bottom and 0.56 in dia. at top in cement mortar 1 :4 (1 cement: 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1 :3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a I loating coat of neat cement, all complete as per standard design: 1.68 in deep with SFBC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete i:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.

16

475371

29710.73

... More
Extra depth for circular type manhole 1.22 in internal dia. (at bottom) beyond 1.68 in to 2.29 in:

5.5

70867

12885.07

... More
Constructing brick masonry circular manhole 1.52 in internal dia. at bottom and 0.56 in dia. at top in cement mortar 1 :4 (1 cemem: 4 coarse sand) inside cement plaster 12 mm thick with cemem mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1 :3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 2.30 in deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight Of cover and frame to be not less than 182 kg fixed in cemem concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.

16

1063112

66444.55

... More
Extra depth for circular type manhole 1.52 in internal dia. (at bottom) beyond 2.30 in:

5.5

171789

31234.44

... More
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.

33

433137

13125.38

... More
Constructing brick circular road gullychamber 1.52 in internal dia. at bottom and 0.56 in dia. at top in cement mortar 1 :4 (1 cemem: 4 coarse sand) inside cement plaster 12 mm thick with cemem mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1 :3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design: 2.30 in deep with SFRC grating Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to IS:12592, total weight Of cover and frame to be not less than 182 kg fixed in cemem concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.

12

780000

65000

... More
Extra depth for circular road gully chamber 1.52 in internal dia. (at bottom) beyond 2.30 in:

5.5

17875

3250

... More
Supply, installation, testing and commissioning of readymade underground Oil Grease trap, which capacity : 3000 Ltr., size 2000MM X 1800MM X 1200MM, suitable for 160mm dia. outlet pipe as required etc. complete the job as directed by Engineer In-charge.

1

150000

150000

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work

-

-

-

... More
20 mm nominal dia Pipes

188.1

50801

270.08

... More
25 mm nominal dia Pipes

5

1919

383.85

... More
32 mm nominal dia Pipes

5

2796

559.3

... More
40 mm nominal dia Pipes

6.6

4252

644.36

... More
50 mm nominal dia Pipes

330

387732

1174.95

... More
65 mm nominal dia Pipes

1980

4122243

2081.94

... More
80 mm nominal dia Pipes

745.8

2035654

2729.49

... More
100 mm nominal dia pipes

1590.6

6406586

4027.78

... More
150 mm nominal dia pipes

33

242359

7344.21

... More
Earthwork in excavation by Mechanical means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

544

246413

452.97

... More
Earthwork in excavation by Mechanical means up to a depth of 2-4m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

2

1103

551.85

... More
Earthwork in excavation by Mechanical means up to a depth of 4-6m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. B) ln ordinary rock (soft rock/ medium rock/ hard shale)

2

1301

650.74

... More
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.ii) Earth Filling(For Marshy Soil)

355

391158

1101.86

... More
Sand filling in plinth in layers not exceeding 150 mm thick including breaking Of clods, consolidating by ramming and watering complete as directed (maximum depth 45 cm)

129

259106

2008.57

... More
PCC: Providing & laying Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including shuttering, centring, formwork, dewatering if necessary, and curing complete. B) M10 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)

80

646571

8082.14

... More
Construction of RCC Thrust Block foundation having size of 700X700X700 mm with RCC as per drawing and having 100mm thick PCC in at bottom level . It includes excavation, back filling, ramming, watering, casting, fair finish shuttering, reinforcement, binding wires, etc. complete in true line level and plum in radiant or level as per detailed design drawing. Contractor shall clean up entire drain and manhole before handing over procedure.

10

91645

9164.58

... More
Construction of Valve Chamber of size 900x800x1000 (1200X1100X1200)mm including excavation, backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C work of for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with 20mm thick sand faced cement plaster in two coat at all sides. Top shall be covered with FRP surface heavy duty Recess Manhole cover with clear opening of 600x600mm with frame and cover as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction of Engineer In-charge.

5

341505

68301.08

... More
Construction of Valve Chamber of size 900x800x1000 (1200X1100X1200)mm including excavation, backfilling, watering, soling, compaction, Reinforcement, Rungs etc. complete. It includes R.C.C work of for walls, top and bottom slabs, also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal and outside of chamber with 20mm thick sand faced cement plaster in two coat at all sides. Top shall be covered with FRP surface heavy duty Solid Top Manhole cover with clear opening of 600x600mm with frame and cover as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction of Engineer In-charge.

20

1415124

70756.24

... More
Providing and fixing mosquito proof stainless steel overflow grating for tanks.( Zoloto/ Audco/ R.B./ Spirex)

17

5950

350

... More
Providing and fixing 80 mm dia. float valve with pressure type PN 16 PTMT float valve.

2

13706

6853

... More
Providing and fixing 100 mm dia. float valve with pressure type PN 16 PTMT float valve.

4

27412

6853

... More
Providing and fixing gun metal gate valve with C.I, wheel Of approved qilality (screwed end): 50 mm nominal bore

12

11241

936.77

... More
65 mm nominal bore

1

1596

1596.01

... More
80 mm nominal bore

6

14246

2374.35

... More
100 mm nominal bore

4

110116

27529

... More
150 mm nominal bore

1

35425

35425

... More
Supply, Installation, Testing and Commissioning of 25 mm dia. air release valve. Make : Varie Model : AV21-T

22

11000

500

... More
Supplying, fitting & fixing of 50 mm dia. Pressure Reducing Valve including Valve Patterns: “Y” (Globe), End Connections: Flanged (all standards), Plug Types: Flat disc, V-port , Cavitation cages, Standard Materials: Body & actuator: Ductile Iron, Bolts, nuts & studs: Stainless Steel, Internals: Stainless Steel, Bronze & Coated Steel Diaphragm: Fabric-reinforced synthetic rubber Seals: Synthetic rubber Coating: Dark blue Fusion bonded epoxy set of approved make.

12

138600

11550

... More
Providing and fixing of 50 mm dia (flanged ends) 600 mm long Ductile Iron Heavy duty PUDDLE FLANGES and BS EN 545 Ductile Iron Pipe with Puddle, BS EN 1092-2 Flange, ISO2531 ductile iron pipes puddle flanges properly fixed in walls & top slab of tanks. Length shall be 600 mm or as per detail drawing.

11

324500

29500

... More
Providing and fixing of 65 mm dia (flanged ends) 600 mm long Ductile Iron Heavy duty PUDDLE FLANGES and BS EN 545 Ductile Iron Pipe with Puddle, BS EN 1092-2 Flange, ISO2531 ductile iron pipes puddle flanges properly fixed in walls & top slab of tanks. Length shall be 600 mm or as per detail drawing.

3

96000

32000

... More
Providing and fixing of 80 mm dia (flanged ends) 600 mm long Ductile Iron Heavy duty PUDDLE FLANGES and BS EN 545 Ductile Iron Pipe with Puddle, BS EN 1092-2 Flange, ISO2531 ductile iron pipes puddle flanges properly fixed in walls & top slab of tanks. Length shall be 600 mm or as per detail drawing.

10

398000

39800

... More
Providing and fixing of 100 mm dia (flanged ends) 600 mm long Ductile Iron Heavy duty PUDDLE FLANGES and BS EN 545 Ductile Iron Pipe with Puddle, BS EN 1092-2 Flange, ISO2531 ductile iron pipes puddle flanges properly fixed in walls & top slab of tanks. Length shall be 600 mm or as per detail drawing.

11

467500

42500

... More
Providing and fixing of 150 mm dia (flanged ends) 600 mm long Ductile Iron Heavy duty PUDDLE FLANGES and BS EN 545 Ductile Iron Pipe with Puddle, BS EN 1092-2 Flange, ISO2531 ductile iron pipes puddle flanges properly fixed in walls & top slab of tanks. Length shall be 600 mm or as per detail drawing.

11

682000

62000

... More
Providing and fixing of 200 mm dia (flanged ends) 600 mm long Ductile Iron Heavy duty PUDDLE FLANGES and BS EN 545 Ductile Iron Pipe with Puddle, BS EN 1092-2 Flange, ISO2531 ductile iron pipes puddle flanges properly fixed in walls & top slab of tanks. Length shall be 600 mm or as per detail drawing.

2

202000

101000

... More
Constructing brick Valve with chamber masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) with Sewer bricks conforming to IS : 4885.

13

3705000

285000

... More
Electromagnetic Flow Meter Supply of Full Bore Electromagnetic Flow Meter( inline) with factory calibrated, IP - 68, Battery with Electrical operated, flanged connection, flow meter, indicator, transmitter and totaliser with all accessories viz. power and control cables upto starter panel, cabinets, hardwares, , communicate all data to BMS, BMS Compatible etc. complete as per following specifications including fixing using flanged specials with bolts, nuts & packing with testing. Scope also including testing and commissioning. I) Flow Sensor: Neoprene/ Polurethene lining, DC Pulsed, SS 316 electrodes, CS/ SS 316 flanges, fully welded/ SS 304 sensor construction & housing. II) Flow Transmitter/ converter: Micropressor based/ Modular design/ HART type, 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totaliser display, one current (4-20 mA)/ one scalable pulse/ one status output, IP 67, Die cast alluminium with PU finish with glass window enclosure, 10 metres length sensor cable. 50mm Diameter.

12

1031400

85950

... More
Electromagnetic Flow Meter Supply of Full Bore Electromagnetic Flow Meter( inline) with factory calibrated, IP - 68, Battery with Electrical operated, flanged connection, flow meter, indicator, transmitter and totaliser with all accessories viz. power and control cables upto starter panel, cabinets, hardwares, , communicate all data to BMS, BMS Compatible etc. complete as per following specifications including fixing using flanged specials with bolts, nuts & packing with testing. Scope also including testing and commissioning. I) Flow Sensor: Neoprene/ Polurethene lining, DC Pulsed, SS 316 electrodes, CS/ SS 316 flanges, fully welded/ SS 304 sensor construction & housing. II) Flow Transmitter/ converter: Micropressor based/ Modular design/ HART type, 2 line back lit LCD for indication of actual flow rate, forward, reverse, sum totaliser display, one current (4-20 mA)/one scalable pulse / one status output, IP 67, Die cast alluminium with PU finish with glass window enclosure, 10 metres length sensor cable. 80mm Diameter.

1

96500

96500

... More
Providing and fixing gun metal non-return valve of approved quality (screwed end): 50mm Diameter.

12

14775

1231.3

... More
80mm Diameter.

1

3091

3091.01

... More
Supply, installation, testing and Commissioning of 20mm Nominal diameter Garden Hydrant with gun metal Ball Valve, GI pipe for Flexible hose Connection, ISI Marked (IS:12585) 20MM diameter Garden hose reel of 30M length, and all required accessories etc. complete the job.

78

49920

640

... More
DOMESTIC WATER TREATMENT PLANT: Supply installation, testing and commissioning of dometic water treatment plant comprising of Pressure sand filter, and softner Plant accrording to input water quality/analysis. Water treatment plant consisting of FRP tank, filter media, resins, brine tank, CPVC SCH 80 piping, isolation valves, instruments supports. The scope shall include CPVC SCH 80 interconnection piping, Butterfly Cast Iron valves, NRV, instruments, autoback wash arrangement, Brine preparation tank & agitator platform, 1 nos Agitator require capacity and Ventury etc.complete the job .Scope shall also includes one month operation including consumable and training for operation of staff. Inlet Flow Range : 10 CMT/ Hr. Output Water Hardness : 50 PPM

1

1250000

1250000

... More
WTP FEED PUMP: Centtrifugal Monoblock Transfer Pump: Supplying, installing, testing and commissioning of centrifugal pumps Complete with SS-316 casing, S.S 316 impeller and SS-316 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal) driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed , dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency, shall be supplied with all accessories viz., base plate, coupling, motor etc. complete. Contractor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. SITC of elctronic type low water level controler with LED panel to operate pump (necessary contacts along with minium one PLC operated spare contacts required), shall prevent the pump from dry running. Mounting Height : 500mm from the bottom of Raw Water tank. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level and cut off at High level complete the job. Mounting Height (Medium Level) : (Domestic Treated water Tank) Mounting Height (Hight Level ): (Domestic Treated water Tank) with probe & all control wiring from Pump room Panel to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Gun Metal Isolation valves, Gun Metal non return valves, pressure gauge with Isolation Valve of PN 10 etc. complete the job. Capacity per pump - 20.0 m3/hour, Head - 35 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation).

1

590000

590000

... More
HYDRO PNEUMATIC SYSTEM for Domestic Water Distribution: Variable Speed Hydro-booster System: Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation). Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 20.0 m3/hour, Head -40 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation), Location - UGT Pump Room, Suction head - flooded positive suction

1

790000

790000

... More
Plant Room Sump Drain Pump: Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/ guide rail. (Pumps suitable to handle solids upto 20 mm size with C.I. body, SS304 shaft, SS impeller). Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Scope shall also include supply, laying, termination of control and power cables of adequate size and arrangemnt of cable trayfrom pump to control panel etc. to complete. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job. Mounting Height (Low Level ): (Sump) Mounting Height (Medium Level) : (Sump) Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Set of accessories such as CPVC SCH 80 headers of discharge for (working and Standby pump assembly) , Gun Metal Isolation valves, Gun Metal non return valves, pressure gauge with Isolation Valve of PN 10 etc. complete the job. Capacity per pump - 5.0 m3/hour, Head -15 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Standby - cascade operation).

1

190000

190000

... More
POND TO UGWT FEED PUMP: Centtrifugal Monoblock Transfer Pump: Supplying, installing, testing and commissioning of centrifugal pumps Complete with SS-316 casing, S.S 316 impeller and SS-316 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal) driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed , dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency, shall be supplied with all accessories viz., base plate, coupling, motor etc. complete. Contractor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. SITC of elctronic type low water level controler with LED panel to operate pump (necessary contacts along with minium one PLC operated spare contacts required), shall prevent the pump from dry running. Mounting Height : 500mm from the bottom of Raw Water tank. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level and cut off at High level complete the job. Mounting Height (Medium Level) : (Domestic Treated water Tank) Mounting Height (Hight Level ): (Domestic Treated water Tank) with probe & all control wiring from Pump room Panel to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Gun Metal Isolation valves, Gun Metal non return valves, pressure gauge with Isolation Valve of PN 10 etc. complete the job. Capacity per pump - 10.0 m3/hour, Head - 35 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Standby - cascade operation).

1

390000

390000

... More
Monsoon i.e. Pond WATER TREATMENT PLANT: Supply Installation, Testing and Commissioning of Pond Water Treatment Plant comprising of Pipe Flocculator, pH correction Dosing system, coagulant Dosing pump, Flocculant Dosing , Tube Settler media accrording to input water quality/analysis. This water treatment plant shall be operated for monsoon/pond water treatment and treated water from this Water Treatment plant shall be furtehr treated with Sr. no. 1 Domestic water treatment plant having, Multimedia Filter and Water softener unit as per requirment. Required CPVC SCH 80 piping, isolation valves, instruments supports in vendor scope. Sludge generated from this water treatment plant shall be under gravity transfererd to sludge tank and then dewatered via. sludge basket centrifuge. The scope shall include CPVC SCH 80 interconnection piping, Butterfly Cast Iron valves, NRV, instruments, autoback wash arrangement, Brine preparation tank & agitator platform, 1 nos Agitator require capacity and Ventury etc.complete the job .Scope shall also includes one month operation including consumable and training for operation of staff. Required civil work for this pond water treatment plant is not in vendor scope. Inlet Flow Range : 10 CMT/ Hr. Output Water Turbidity : 01 PPM

1

950000

950000

... More
Monsoon i.e. Pond WATER TREATMENT PLANT: Supply Installation, Testing and Commissioning of Pond Water Treatment Plant comprising of Pipe Flocculator, pH correction Dosing system, coagulant Dosing pump, Flocculant Dosing , Tube Settler media accrording to input water quality/analysis. This water treatment plant shall be operated for monsoon/pond water treatment and treated water from this Water Treatment plant shall be furtehr treated with Sr. no. 1 Domestic water treatment plant having, Multimedia Filter and Water softener unit as per requirment. Required CPVC SCH 80 piping, isolation valves, instruments supports in vendor scope. Sludge generated from this water treatment plant shall be under gravity transfererd to sludge tank and then dewatered via. sludge basket centrifuge. The scope shall include CPVC SCH 80 interconnection piping, Butterfly Cast Iron valves, NRV, instruments, autoback wash arrangement, Brine preparation tank & agitator platform, 1 nos Agitator require capacity and Ventury etc.complete the job .Scope shall also includes one month operation including consumable and training for operation of staff. Required civil work for this pond water treatment plant is not in vendor scope. Inlet Flow Range : 10 CMT/ Hr. Output Water Turbidity : 01 PPM

1

275000

275000

... More
Sewage Treatment Plant- 86 KLD: Design, Supplying, installing, testing & commissioning of Sewage Treatment Plant of 86 KLD (excluding excavation, back filling & disposal of surplus earth civil construction work, inside STP area illumination, air ventilation system) for the following duty: a. Screen chambers followed by O&G trap with SS Screen and Oil skimmer unit, b. Equalization Tank with coarse bubble aeration, c. Anoxic mixer with anoxi tank and MBBR aeration tank with media protection screens with MBBR media, d. Air Blowers, e. Recirculation pumps, f. filter feed pump, g. Multimedia filter, h. activated carbon filter, i. chlorine Dosing system, j. fully automatic out to in type UF system, k. Dewatering system, l. Electrical Panel, Cabling (Power & Control), Earthing, m. electromagnetic flow meters, n. Clear Water tank, Flushing Water tank and Ultra Violet unit, INLET SEWAGE CHARACTERSTICS in mg/L except pH (assumed),

1

2450000

2450000

... More
pH 6.5 to 8.5, Total Suspended Solids 200, BOD 250-350, COD 350-500, Oil & Grease up to 50, NH4N 25 to 30, TN 90 to 100, Coliform ≤100000 and outlet Treated water quality in mg/L except pH required pH 6.5-9.0 Total Suspended Solids (mg/l) 05, BOD (mg/l) 10, COD 50, Oil & Grease 10, NH4N 5 TN 10, Coliform (MPL/100ml)1000. The treated water shall be reused HVAC make up , irrigation etc.. The detailed specification as mentioned in tender document to be strickly followed by vendor for major scope of STP. The Contractor shall ensure submission of detailed GA drawings (Plan & Section), P&l diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.

-

-

-

... More
HYDRO PNEUMATIC SYSTEM for Irrigation Water Distribution: Variable Speed Hydro-booster System: Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation). Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 5.0 m3/hour, Head -50 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Standby - cascade operation), Location - STP Pump Room, Suction head - flooded positive suction

1

325000

325000

... More
Drilling of bore hole an Alluvial strata by direct Rotary rig/ DTH rig size 250/300mm diameter.

166.1

198204

1193.29

... More
Reaming of 250/300 pilot bore hole including Assembling, lowering housing casing, strainer pipes, gravel packing, clay packing etc. complete size 550mm diameter.

166.1

122577

737.97

... More
Manufacture, supply and delivery of ISI marked ERW M.S. pipes conforming to IS: 4270/2001 with latest amendment in random length of 4 to 7 meter size 250mm diameter (min. 7.10 mm thickness)

165

820193

4970.87

... More
Job work of slotting of M S ERW blind pipe of following size having slot size as 6.75 cm x 6.35 cm x 3.12 mm (including unloading of blind pipes from truck and reloading slotted pipes into truck).

8910

2940

0.33

... More
Clamp made from M.S. plate with 3 holes on either side with nuts and bolts of Std. Make and suitable size. 900 mm X 100 mm X 16 mm flat suitable for 250 mm dia.Pipe.

1

2809

2809.49

... More
Bore plug having 100 mm height made from M.S. plate with 3 holes at equal distance on circumference for nut-bolts type, locking arrangement with nuts-bolts and lock nuts of standard make complete. From 5mm thick M.S. plate (for top also) suitable 250mm diameter pipe.

1

1601

1601.43

... More
M.S. Bail plug having length 0.45 mtr from medium class pipe as per I.S.S. suitable for 250mm diameter pipe.

1

1468

1468.26

... More
Steel bent plates suitable to 250 mm dia ERW pipe size 200 mm x 150mm x 6 mm.

121

15297

126.43

... More
Supply of Best quality of well sorted Sevaliya gravel of size 4mm to 6mm.

38.5

108801

2826.01

... More
Cement sealing including the cost of cement by means of mud pump.

1

8774

8774.91

... More
Charges of electrologging test of bore hole.

1

25063

25063.2

... More
Lowering and removing of 100mm dia. Drop line and 32mm dia air line for development of each water bearing zones comes across upto the full depth of deep tube well size 200mm/ 250mm/ 300mm dia. For the tube well having depth of 186 meter and above through suitable air compressor. the job is for complete period of development of tube well without air compressor charges.

1

38676

38676.65

... More
Charges of air compressor capacity 900 CFM/200 including all the require accessories and machineries. (Min 6hr and upto sand free discharge)

1

11717

11717.05

... More
Supply of Clay ball of size 25mm to 50mm from Stickly Clay at site of work. As certified by Hydrologist.

11

11502

1045.69

... More
Carrying out geological and hydrogeological investigation to understand the deposition pattern of geological layers and assess the groundwater potential and identify available litholog of the perticular location/ point with probable formation material with depth/ thickness of the layer along with approximate permiability and transmetivity of specific material to calculate water bearing capacity and rainwater recharge capacity be following methods. (Geophysical Survey Involving Earth Resistivity Principals Vertical electrical sounding using Schlumberger 4 Electrode Array)

1

20060

20060

... More
Carrying out geological and hydrogeological investigation to understand the deposition pattern of geological layers and assess the groundwater potential and identify available litholog of the perticular location/ point with probable formation material with depth/ thickness of the layer along with approximate permiability and transmetivity of specific material to calculate water bearing capacity and rainwater recharge capacity be following methods. (Geomagnetic Survey by using TESLA 6 ground water detector or similar equipment working on magnetotellurics 6 channel detection method)

1

20060

20060

... More
Supplying, installation, testing and commissioning of Submersible Multi Stage Pump Set conforming to I.S. 8034 and motor conforms to IS-9283 working at 3 phase 400/440 volt 50 C/S A.C. supply & 2900 R.P.M. Complete in Stainless steel 316 including with body, casing, impeller, shaft to suitable to handle clear water. Pump should be completely made of stainless Steel 316 construction to avoid the corrosion formation. All bearings are water lubricated and octagonally shaped bearings for sand flush, inlet strainer for prevents entering of particles , in-built non return valve for preventing back flow and reduce the water hammer, stop ring for prevents damage of the pump due to up-thrust load. Pump should coupled with high efficiency oil cooled submersible motor with ball bearing for smooth operation. Motor should be re-windable type made in stainless steel 316 parts in contact with water, memovable cable connector for allow fast and easy maintenance and In-build overload motor protection feature need to be provided. Pumps should be tested as per ISO 9906 standard.

1

1180000

1180000

... More
Pump: SS 316, Impeller: SS 316, Motor: SS   316, Enclosure class (IEC 34-5): IP 68, Insulation class (IEC 85): F Supply, installation, testing and commissioning of made from Panel mounted Star Delta starter, Supplying & erecting approved make motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON-OFF isolator (AC 3/23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for Setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of approved make only).  Scope shall also include local & remote pump control application consisting of MPCB, ON-OFF and Trip Indicating lamps in each incomer and outgoing feeders, overload relay and contactors as per Type II coordination including digital voltmeter, analogue ammeter with selector switch, run hour meter, required protective relays & control accessories with suitable out door IP 55 enclosure. Scope shall also include remote on/off operation complete as require. The on/off operation for all pumps shall be available on central BMS system. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS. Scope shall also include supply, laying, termination of power cables of adequate size and arrangement of cable tray from Borewell to to Control panel etc. to complete the job. Scope shall also include 6A separate feeder in the panel for Flow meter. Supplying & erecting approved make Automatic liquid level controller 6A as per instruction of Engineer In-charge on site complete with wiring connection, with copper conductor from pump to upper and lower tank. Capacity per pump- 15.0 m3/hour, 1 Set.= 1 Nos. Pump, Head- 150 metre.

-

-

-

... More
Supply, installation, testing and commissioning of 63mm diameter UPVC column pipe of Heavy grade in the borewell of required depth, with "O" rings on the threads makes the joints watertight and absorb pump vibrations. These rings are made from EPDM (Ethylene Propylene Diene Monome) rubber which is most suitable for drinking water option with negative thermal expansivity. Scope shall also unclude for CI pipe adaptor and pump adaptor for UPVC column pipes.

165

117150

710

... More
Supply, installation, testing and commissioning of Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible copper cable in the borewell of required depth approved make of following size. Size: Cu- 3Cx35 sqmm

330

382800

1160

... More
Supply, installation, testing & commissioning of Submersible non clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail.(Pumps suitable to handle solids upto 25 mm size with C.I. body, SS304 shaft, SS impeller ).Panel mounted PLC based pump controller, IP 55 enclosure, ON-OFF and Trip Indicating lamps in each incomer and outgoing feeders, adequate NO NC contacts for integrating with Building Automation System, interlocking arrangement, dry run protection, cascade operation, working / standby selection, with provision of remote on/off operation complete as require. The on/off operations for all pumps shall be available on central BMS system.

15

1350000

90000

... More
Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS. Scope shall also include supply, laying, termination of control and power cables of adequate size, and arrangement of cable tray from Pump to Control panel etc. to complete the job.SITC of elctronic type High & Low water level controler with LED panel to operate pump (necessary contacts along with minium one PLC spare contacts required),level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running. Mounting Height (Low Level) : 100mm bottom of Sump Mounting Height (High Level) : 1000 mm from the bottom of SumpSet of accessories such as CPVC SCH 80 discharge headers for (working and stand by pump assembly) from sump bottom to Basement ceiling, control valves, non-return valves, pressure gauge of PN 10 etc. complete the job.

-

-

-

... More
Providing, installing, testing and commissioning of HDPE pipes confirming to IS 4984 or ISO 4427 suitable for the respective working pressures with all electrofusion or compression type PN16 fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction, with excavation & backfilling upto 600mm for main and 450 mm for submian depth. Make : Reliance/ Smartflows/ Supreme

-

-

-

... More
HDPE Pipe 90mm PN 6

36

19224

534

... More
HDPE Pipe 75mm PN 6

1545

630360

408

... More
HDPE Pipe 63mm PN 6

420

133560

318

... More
Piping Network Providing and fixing of following dia. white PVC pipe conforming to ASTM D 1785 SCH 40 or D 2241 Class 200/ 315 standards with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. as required with excavation & backfilling upto 450mm for for submian depth. Make: Rainbird/ Smartflows/ Supreme

-

-

-

... More
PVC Pipe Sch 40 / Class 200 2.5" - 65mm

36

22320

620

... More
PVC Pipe Sch 40 / Class 200 2" - 50mm

72

29952

416

... More
PVC Pipe Sch 40 / Class 200 1-1/2" - 40mm

210

69510

331

... More
PVC Pipe Sch 40 / Class 200 1-1/4" - 32mm

9400

2735400

291

... More
Drip & Accessories

-

-

-

... More
Providing, installing, testing and commissioning of 16mm inline tubing with pressure compensating,, Flat emitter and resistance to UV damage, algae growth brown in colour from outer surface and black innter surface, with flow rate 3.4 lph, dripper spacing 18" Pressure rating 0.58 to 4.1 kg/cm2 wall thickness 1.2mm The flexible polyethylene tubing shall have factory-installed pressure-compensating, inline emitters installed every 18 inches. The flow rate from each installed inline emitter shall be 3.4 Litre per hour. The inline emitter shall be pressure compensating with a spring-action design which will provide a a self-rinsing mechanism if grit accumulates within the emitter. The bend radius shall be 3 inches whether bending the tubing with the natural bend of the coil or against it. The inline emitter inlet shall be raised off the inside tube wall to minimize dirt intrusion. Make: Rainbird/ Smartflows/ Toro/ Netafim

21128

1415576

67

... More
Providing, installing, testing and commissioning of High Quality kg/cm2b Grab Tubing for a Secure Fit. Unique kg/cm2b Design to Reduce Insertion Force. Non-obtrusive 17mm Insert Fittings - Brown Color - Take Off Adopter, Elbow,Tees, End Cap with PP Clamp Saddle having nuts and bolts in zinc chromed steel, o-ring gasket in NBR. Male: Rainbid/ Toro/ Smartflows/ Netafim

475

141075

297

... More
Providing, installing, testing and commissioning of 9" Long Galvanized Lateral Hold Stake Make: Rainbird/ Toro/ Smartflows/ Netafim

4226

71842

17

... More
Sprinklers & Accessories

-

-

-

... More
Providing, installing, testing and commissioning of 4" Pop up spray head with SAM PRS Series Spray bodies , having Co-moulded wiper seal is moulded into the cap and features an encased plastic 'cage' to provide resistant to grit, with Spray nozzle having mutilple stream MPR sprayhaving Co-moulded wiper seal is molded into the cap and features an encased plastic 'cage' to provide unmatched resitence to grit, nozzle capable of covering 1.8-5.4m at 1.4 - 3.8 kg/cm2s pressure, and the enviroment. Rotary nozzles shall have hand adjustable ( without tools) radius and arc-45 to 270 degree or full circle,True flushing mechanism,Thick streams and large water droplet & Low precipitation rate. Make: Rainbird/Toro/Weathermatics

19

15941

839

... More
Providing, installing, testing and commissioning of 12" Pop up spray head with SAM PRS Series Spray bodies , having Co-moulded wiper seal is moulded into the cap and features an encased plastic 'cage' to provide resistant to grit, with Spray nozzle having mutilple stream MPR sprayhaving Co-moulded wiper seal is molded into the cap and features an encased plastic 'cage' to provide unmatched resitence to grit, nozzle capable of covering 1.8-5.4m at 1.4 - 3.8 kg/cm2s pressure, and the enviroment. Rotary nozzles shall have hand adjustable ( without tools) radius and arc-45 to 270 degree or full circle,True flushing mechanism,Thick streams and large water droplet & Low precipitation rate. Make: Rainbird/Toro/Weathermatics

277

232403

839

... More
Providing, installing, testing and commissioning of 4" Pop up Spray head with SAM PRS Series Spray bodies , having Co-moulded wiper seal is moulded into the cap and features an encased plastic 'cage' to provide resistant to grit, with Rotary nozzle having mutilple stream MPR sprayhaving Co-moulded wiper seal is molded into the cap and features an encased plastic 'cage' to provide unmatched resitence to grit, nozzle capable of covering 4.0-7.3m at 1.4 - 3.8 kg/cm2s pressure, and the enviroment. Rotary nozzles shall have hand adjustable ( without tools) radius and arc-45 to 270 degree or full circle,True flushing mechanism,Thick streams and large water droplet & Low precipitation rate. Make: Rainbird/Toro/Weathermatics

92

124752

1356

... More
Providing, installing, testing and commissioning of 4" Pop up spray head with SAM PRS Series Spray bodies , having Co-moulded wiper seal is moulded into the cap and features an encased plastic 'cage' to provide resistant to grit, with Rotary nozzle having mutilple stream MPR sprayhaving Co-moulded wiper seal is molded into the cap and features an encased plastic 'cage' to provide unmatched resitence to grit, nozzle capable of covering 4.0-7.3m at 1.4 - 3.8 kg/cm2s pressure, and the enviroment. Rotary nozzles shall have hand adjustable ( without tools) radius and arc-45 to 270 degree or full circle,True flushing mechanism,Thick streams and large water droplet & Low precipitation rate. Make: Rainbird/Toro/Weathermatics

362

1262656

3488

... More
Providing, installing, testing and commissioning of 1/2" x 12" Long Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. Flex pipe textured for wet conditions.The fittings shall be made of UV resistant thermo plastic with PP Clamp Saddle Chromed Nut Bolt & Nitrile Rubber Gasket Make:Lasco/Toro/Rainbird/Smarflows/Astore

111

41736

376

... More
Valves Providing, installing, testing and commissioning of various Valves with required Fittings & Tapping PP Clamp Saddles with Chromed Nut Bolt & Nitrile Rubber Ring.

-

-

-

... More
Providing, installing, testing and commissioning of 2" 50mm Gate Valve, MOC Brass, Non Rising Stem, Full Port, 200 / 14 kg/cm2 PSI, BSPT Make: NIBO/ LEADER/ Leemco

8

46968

5871

... More
Providing, installing, testing and commissioning of 1-1/2" 40mm Gate Valve, MOC Brass, Non Rising Stem, Full Port, 200 / 14 kg/cm2 PSI, BSPT Make: NIBO/ LEADER/ Leemco

19

105773

5567

... More
Providing, installing, testing and commissioning of 1-1/4" 32mm Gate Valve, MOC Brass, Non Rising Stem, Full Port, 200 / 14 kg/cm2 PSI, BSPT Make: NIBO/ LEADER/ Leemco

30

158640

5288

... More
Providing, installing, testing and commissioning of PVC Butter Fly Valve 75mm (2.5") PN 10, having EPDM Seals, Galvnized Steel Stem Disc - PVC U Make: Astore/ GF/ FIP

3

40710

13570

... More
Providing, installing, testing and commissioning of PVC Butter Fly Valve 63mm (2.0") PN 10, having EPDM Seals, Galvnized Steel Stem Disc - PVC U Make: Astore/ GF/ FIP

3

38622

12874

... More
Providing, installing, testing and commissioning of PVC Flush Valve 40mm Make: Rainbird/ Smartflows/ Netafim

64

18048

282

... More
Providing, installing, testing and commissioning of 3/4" Quick Couppling Valve Make: Rainbird/ Toro/ Smartflows

49

339423

6927

... More
Providing, installing, testing and commissioning of 3/4" Quick Couppling Valve Key Make: Rainbird/ Toro/ Smartflows

5

33800

6760

... More
Providing, installing, testing and commissioning of Saddle Tee 160/140/110/90/75/63mmX3/4" witth ASTM Pipe (12" Long) Make: Asore/ Smartflows/ Astral

49

63308

1292

... More
Providing, installing, testing and commissioning of Swivel Elbow 3/4" X 3/4" Make: Rainbird/ Toro/ Smartflows

5

37060

7412

... More
Providing, installing, testing and commissioning of 1" - 25mm Double Acting Air cum Vacum Release Valve, Body: Glass-reinforced Nylon, Float Assembly: Polypropylene, Elastomers: EPDM, operating pressure minimum 0.1 kg/cm2, maximum 10 kg/cm2, Aerodynamic full-body kinetic shield, Straight flow body with large diameter orifice size 0.787mm dia and area of 0.496 sqmm. Make: Bermad/ Rainbird/ Crispin

5

10630

2126

... More
Providing, installing , testin and commissioning of PP Saddle Tee 160/140/110/90/75/63mmX1" witth ASTM Pipe (12" Long) Make: Astore/ Smartflows/ FIP/ Astral

5

6460

1292

... More
Providing, installing, testing and commissioning of 12" Rectangular Standard Commercial grade Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening: 14.5" L X 9.4" W 12.1" H & bottom opening: 18.7" L X 14.1"W with Nut Bolt Lock Make: RainBird/ Toro/ Smarflows

57

273429

4797

... More
Providing, installing, testing and commissioning of 10" Round Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening 8.9" Dia & Bottom Opening 11.9" Dia,with Nut Bolt Lock Make: RainBird/ Toro/ Smarflows

52

153088

2944

... More
Providing, installing, testing and commissioning of 6"Round box with greenlid Having Dimensions @ Top Opening :6 1/8" Dia & Bottom Opening 8 5/8" Dia, with Nut Bolt Lock Make: RainBird/ Toro/ Smarflows

5

3550

710

... More
Providing, installing, testing and commissioning of 12" Jumbo Rectangular Standard Commercial grade Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening: 18.7" L X 12.2" W & bottom opening: 24" L X 17.5 "W X 12.1" H, with Nut Bolt Lock Make: RainBird/ Toro/ Smarflows

3

27471

9157

... More
Providing, installing, testing and commissioning of 4.0" Hydro Meter - Water Meter cum Master Valve in one common body Make: Rainbird/ Bermad/ Smartflows/ Cal-Valve

1

165413

165413

... More
Providing, installing, testing and commissioning of 2.0" Hydro Meter - Water Meter cum Master Valve in one common body Make: Rainbird/ Bermad/ Smartflows/ Cal-Valve

1

90478

90478

... More
Providing, installing, testing and commissioning of 230V Input, DC output Irrigation Controller combines electromechanical and microelectronic circuitry capable of fully automatic or manual operation. Make: Netafim/ Toro/ Rainbird

1

136463

136463

... More
Providing, installing, testing and commissioning of D.C. 2"-50mm Durable Glass filled nylon Solenoid Valve - BSP Female Threaded, with Nylone scrubber/ Filter Sentry Pressure- 1 to 13.8 kg/cm2 along with Filed Device - DC Solienoid Coil with interface module in-built in one device mountable on Solenoid Valve to connect Controller and Valve on one wire path Make: Bermad/ Netarim/ RainBird/ Toro

5

118620

23724

... More
Providing, installing, testing and commissioning of D.C. 1.5"-40mm Durable Glass filled nylon Solenoid Valve - BSP Female Threaded, with Nylone scrubber/ Filter Sentry Pressure- 1 to 13.8 kg/cm2 along with Filed Device - DC Solienoid Coil with interface module in-built in one device mountable on Solenoid Valve to connect Controller and Valve on one wire path Make: Bermad/ Netarim/ RainBird/ Toro

9

195345

21705

... More
Providing, installing, testing and commissioning of D.C. 1"-32mm Durable Glass filled nylon Solenoid Valve - BSP Female Threaded, with Nylone scrubber/ Filter Sentry Pressure- 1 to 13.8 kg/cm2 along with Filed Device - DC Solienoid Coil with interface module in-built in one device mountable on Solenoid Valve to connect Controller and Valve on one wire path Make: Bermad/ Netarim/ RainBird/ Toro

43

836995

19465

... More
Providing, installing, testing and commissioning of Flow Sensor Make: Bermad/ Netarim/ RainBird/ Toro

1

116276

116276

... More
Providing, installing, testing and commissioning of Rain Sensor Make: Bermad/ Netarim/ RainBird/ Toro

1

19944

19944

... More
Providing, installing, testing and commissioning of Maxi Jackated Direct Burrial Irrigation Automation Cable 14 AWG Tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductor - Soft annealed tin coated solid copper conforming to ASTM B-33. Insulation: Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF/TWU rated 75°C. Outer Jacket: Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3/64" minimum jacket material to completely fill interstices between the two insulated conductors. Make: RainBird/ Paige/ Smartflows/ Toro

1850

407000

220

... More
Providing, installing, testing and commissioning of Pressure Regulatr to Maintain constant outlet pressure between 1.04 to 6.9 Kg/cm2 Make: Bermad/ Netarim/ RainBird/ Toro

16

89936

5621

... More
Providing, installing, testing and commissioning of direct bury -on wire connector with strain relief, UL486 D certified, with waterproof silicon sealant, fits wire from 22ga to 6ga as per specifications complete. Make 3M/ Smartflows/ Rainbird

280

64680

231

... More
Providing, installing, testing and commissioning of Surge Protector Make: Bermad/ Netarim/ RainBird/ Toro

12

120924

10077

... More
Providing, installing, testing and commissioning of Copper Grounding Rod 5/8" x 8' Make: Paige/ Smartflows/ Rainbird

12

90708

7559

... More
Providing, installing, testing and commissioning of Maxi Surge Pipe Make: Bermad/ Netarim/ RainBird/ Toro

1

36740

36740

... More
Providing, installing, testing and commissioning of Maxi Grounding Plate Make: Bermad/ Netarim/ RainBird/ Toro/ Paige

1

45137

45137

... More
Providing, installing, testing and commissioning of Voltage Stabilizer Make: APC/ V Guard/ Lumineous

1

19944

19944

... More
Providing, installing, testing and commissioning of PLB Duct Pipe 32/26mm with pre inserted 3mm nylone rope for cable pulling, length Make: Supreme/ Smartflows/ Reliance

1900

241300

127

... More
Providing, installing, testing and commissioning of Filter Station Fully Automatic Self Cleaing Filter, Pressure Differential Based, 100/130 Micron, Flanged End & all required Accessories. Screen Filter Self Cleaning 25 m3/Hr Make: Rain Bird/ Yardeney/ Smartflows/ VAF

1

234833

234833

... More
Providing, installing and commissioning of Pumping System - Vurticle Multistage Pump having system flow of 18 m3/Hr @ 85 Mtr Head (1 Working + 1 SB), combination of 2 Pumps capacity of 18 m3/Hr @ 85m Head of each Pumps with All Header, Pressure Tank, Pressure switch, NRV and Butter Fly Valve with VFD Control Panel with all GI C Class Pipes and Fittings (Jindal/ TATA/ Surya) etc. complete as directed by Engineer In-charge Make: Grundfos/ ITT/ Smartflows/ Watertronics

1

1494389

1494389

... More
Providing, installing and commissioning of Surge anticipation cum Quick Pressure relief Valve 2" Make: Bermad/ Rainbird/ Cal-Valve

1

205891

205891.41

... More
Providing, installing and commissioning of DWC SN 8 Pipe 6"- Road Sleeve. Make: Supreme/ Duraline/ Astral/ Smartflows

204

240312

1178



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.