Construction I/c Metalling And Blacktopping Of A Road From Bholaganj To Nongjri (6.19 Km) (mg/02/iii/08/12)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pavement

-

-

-

... More
Construction of Embankment with Materials Obtained from Roadway Cutting-Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

8563.26

222

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

14300

20

-

... More
Construction of Subgrade and Earthen Shoulders(Relaying) Stripping, Storing and Relaying Top Soil from Right-of-Way (R.O.W)

3343.68

241

-

... More
Stabilization of in-situ (existing pavement crust) or soil or otherwise sub-base/base course upto the required depth by cold in-situ recycling using cement and chemical additives/otherwise. Providing,pulverizing, spreading, milling and mixing of chemical additives at appropriate rate as per Job Mix design in accordance with IRC-Sp-72-2015, IRC-37-2012 & 2018 and IRC SP 89 (Part II) 2018. Supply and Application of Polymer Treated Base Course (250 mm thick) - Good quality soil of approved quality having desired grading, CBR & PI values or mixing the borrow soil with suitable soil to have consistent desired grading, CBR & PI values with all lead and lift and spreading the same in layers not exceeding around 250 mm thickness, alternatively ripping the existing soil to 250 mm depth if same soil meets the desired grading, CBR & PI values or else mixing same with suitable approved soil from borrow area with all lead and lift to have consistent desired

-

-

-

... More
grading, CBR & PI values. Spreading this approved soil layer evenly. Additive of desired dosage (as per design) is premixed with water to ensure moisture content of soil to achieve 1% excess of OMC when mixed properly and consistently. This premixed additive is sprayed over the evenly spread soil at controlled manner and mixed with tractor plougher to achieve desired consistency and followed by grader blade to required profile & levels and compacted with 10 ton capacity vibratory power roller to achieve the desired dry density of 95-98% and to ensure a minimum consistent thickness of 250 mm of treated soil layer all through, complete as per IS 2720-part 8, with all labour, hire charges for tools and plants employed and other incidentals charges to completed the work as a whole as per the specification and as directed by the engineer in charge.

8939.7

3719

-

... More
Wetmix macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.

2681.91

4639

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achievethe desired compaction as per MORTH specification Clause : 509 complete in all respects

1430.35

13702

-

... More
Prime coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

35758.8

32

-

... More
Road Safety Work

-

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801- a) 600 mm circular

12

3438

-

... More
b) 600 mm Square

6

3718

-

... More
c) 900 mm Equilateral Triangle

52

3682

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

2

6825

-

... More
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work-Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702 II) Bitumen (S-65)

2786.4

156

-

... More
Guide post-Providing guide post on valley side of formation as per drawing and Technical Specification Clause 1608.2.6

515

2458

-

... More
Road Furniture Work PMGSY Logo Board-Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate

-

-

-

... More
by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1- (i) Logo Board at starting point (As per fig. 107 of Road signage under PMGSY published by the NRRDA on Dec'06)

2

39046

-

... More
Kilometre Stone

-

-

-

... More
Construction of 5th Kilometre Stone (Precast)

1

5415

-

... More
Construction of Ordinary Kilometre Stone (Precast) :

7

3121

-

... More
Construction of 200 Metre Stone (Precast) :

24

876

-

... More
Trapizodial shaped drain

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth

560

363

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 (1:5)

125

7893

-

... More
Breast Wall

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth

208.78

363

-

... More
Providing concrete for plain/reinforced concrete (M10) in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 1:3:6

56.1

6616

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 iii)Random rubble masonry iii)in cement mortar 1:5

485.98

7893

-

... More
Back filling behind retaining wall/breast wall Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

173.25

222

-

... More
Filter material behind retaining wall / breast wall as per Specification Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 II) sandy material

22.11

3161

-

... More
Providing P.C.C. M 20 architectural coping on top of retaining wall/breast wall Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11

110

482

-

... More
Cross Draiange Work: Hume Pipe Culvert

-

-

-

... More
Earthwork excavation upto 3.0 m depth in ordinary soil for structures as per drawing and Technical Specifications Clause 305.1 including setting out construction of shorting and bracing, removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material including pumping out water, lighting, barricading, protecting etc. complete as per Technical Specification of Rural Roads.

288

363

-

... More
Providing Concrete (M-15) for Plain Concrete in open foundations complete as per drawing and Technical specification clause 802, 803, 1202,& 1203. PCC Grade M-15 for catch pit

288.45

6347

-

... More
Providing concrete plain / reinforced concrete in substructure for height upto 5m complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 807, 1202 & 1204 of Specification of Rural Roads including curing complete. PCC Grade M-20 Nominal. For Side wall.

72

7782

-

... More
Head Wall

15.36

7782

-

... More
For RCC Slab

37.8

7782

-

... More
Providing and laying reiforcemented cement concrete Pipe NP-3 1000mm dia for culverts on first class bedding of granular material in single row including fixing collar wirh cement morter 1:2 but excluding excavation, protection works, back filling, concrete and masonry works in head wall and parapets including pumping out water, lighting, barricading, protecting etc complete as per vide clause 1106 of Specification of Rural Roads, MORD.

15

50498

-

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. 8 Dia reiforcement in long & short dierection

406.09

70

-

... More
Good and Service Tax (18%)

0.18

-

-

... More
Five Years Maintenance

-

-

-

... More
Maintenance for 1st Year

6.19

172480

-

... More
Maintenance for 2nd Year

6.19

199773

-

... More
Maintenance for 3rd Year

6.19

250322

-

... More
Maintenance for 4th Year

6.19

364664

-

... More
Maintenance for 5th Year

6.19

446866

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.