Pradhan Mantri Gram Sadak Yojana Tender
View complete overview of Meghalaya PMGSY Tender
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Civil And Construction
Bridge Construction
Eprocure
Opening Date11 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 3,81,16,823
Costs
EMD
₹ 7,62,336Document Cost
₹ 4,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEMEG_137300_1Bid Award Id
ViewTender No
MG07III0104B1Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
2557
137
-
... More
Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
731
221
-
... More
Excavation in hilly areas in hard rock requiring blasting, by mechanical means, lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2.
364.92
451
-
... More
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
3382.77
65
-
... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
270.15
222
-
... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
270
659
-
... More
GSB- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
291.32
4010
-
... More
CTB : Providing, laying and spreading soil on a prepared sub-grade, pulverising, adding the designed quantity of cement to the spread soil, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-base/base as per Technical Specification Clause 404.
189.94
5026
-
... More
Prime Coat- Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
1899.38
49
-
... More
Tack Coat- Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503..
1899.38
16
-
... More
Mix Seal Surfacing ; Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509
1899.38
308
-
... More
Supply, Fitting, and Fixing R.C. Guard : Post 1.37m long with cement concrete 1:2:4 with graded stone chips of 13.2mm down casting curing complete including cost of providing 4 nos of 12mm dia MS road of length 1.54m as main reinforcement including loading into the truck and unloading at site complete in all respects.
200
1025
-
... More
Foundation
-
-
-
... More
Earthwork in excavation for strcutures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and vracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material- (i) upto 3.0m depth
453.03
363
-
... More
Earthwork in excavation for strcutures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and vracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material- (ii) 3m to 6m depth
312.44
431
-
... More
Providing concrete for Plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203- PCC M 15 (i) Nominal mix 1:2.5:5 in leveling course below Abutment, pier
16.93
8343
-
... More
Plain/Reinforced Cement concrete, in Open Foundation complete as per Drawing and Technical Specifications.
E. RCC M 35 Grade
Case – I : Using Concrete Mixer
148.68
9817
-
... More
Supplying, fitting and palcing HYSD bar reinforcement in foundation complete as per drawing and technical specifications clause 1000 and 1202
5.04
75247
-
... More
Providing and inserting dowels bars of 25 mm dia (TMT) to a depth of 500 mm anchored in the hard rock by grouting with cement slurry, as per specification and making good all complete as directed.
134
11119
-
... More
Substructure
-
-
-
... More
Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications Clauses 802, 804, 805, 806, 807, 1202 and 1204. A. With Crushed stone- IV. RCC Grade M35-(I) Height up to 5.0m
170.39
10310
-
... More
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications clause 1002, 1005, 1010 & 1202
20.49
75416
-
... More
Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
651
2227
-
... More
Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
651
1969
-
... More
Providing weep holes in Brick masonry/Plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope IV: 20H towards drawins face. Complete as per drawing and Technical s
48
527
-
... More
Backfill behind abutment, wing wall and return wall complete as per drawings and technical specification clause 1204.3.8- Granular Material
74.42
3280
-
... More
Superstructure
-
-
-
... More
Supply and fabrication of Structural Steel in Truss member, Stringer, Cross Girder etc. including wastage for Gusset Plate, Lacing, Batten Plate Shear Connector.
88.46
154128
-
... More
Furnishing and Placing Reinforced/Pre stressed cement concrete in super-structure as per drawing and Technical Specification including steel shuttering formwork. (N) Without plasticiser
B. RCC Grade M25 (Using Concrete Mixer) (II) For T-Beam and Slab- (q) Height up to 5.0 m
43.38
10874
-
... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (a) TMT- IS 1786 (Fe- 500 D) from Primary Producer: TAT/SAIL/Esser Steel/ Shyam Steel/RINL) in Superstructure complete as per drawing and technical specifications. Clauses 1002, 1010 and 1202
8.46
77286
-
... More
Providing and laying cement concrete wearing coat M30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3. (A) With crushed stone.
15
16187
-
... More
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification
55.6
4255
-
... More
Drainage spouts complete as per approved drawings and technical specification clause 1209.
8
2086
-
... More
PCC M15 ordinary grade (1:2.5:5) in levelling course below approach slab complete as per drawing and technical specifications clause 800 & 1211. (A) With crushed stone.
7.09
8106
-
... More
RCC approach slab with M25 grade approach slab including reinforcement and form work complete as per drawing and technical specifications clauses 800 & 1211. (A) With crushed stone.
13.5
14690
-
... More
Providing and laying strip seal expansion joint catering to maximum horizontal movement up to 70mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/ supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation.
15
38447
-
... More
PROTECTION WORKS
-
-
-
... More
Providing and laying boulders apron laid in wire crates with 4mm dia GI wire conforming to IS:280 and IS:4826 in 100mm×100mm mesh (woven diagonally) including 10 percent extra for laps and joints laid with stone boulders weighing not less than 25kg each as per drawing and technical specifications clause 1301.
111.68
13171
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications clause 1302. I. Stone/Boulder
56.65
3764
-
... More
Providing and laying filter material underneath pitching in slopes as per drawing and technical specification clause 1302.
56.65
4849
-
... More
Good and Service Tax (18%)