Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair To Internal Wiring In Otm Accn At Af Stn Singarsi Under Age I Af Singarsi in East Khasi Hills, Meghalaya, with an estimated contract value of Rs. 9,00,000. The bid opening date for this tender is 03-06-2025 and the last date for bid submission is 23-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jun 2025
Closing Date23 Jun 2025
Tender Amount₹ 9,00,000
Costs
EMD
₹ 18,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_712108_1Tender No
C/8758/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No 2 here-in-before but for one 5 pin socket outlet 5 Amps on the same board with other switches,complete all as specified and as directed.
20
10
-
... More
All as per Item No 2 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with 2.5 Sqmm copper cable FRLS & 1.5 Sqmm FRLS copper cable for earth continuity wire,complete all as specified and as directed.
20
10
-
... More
S&F sub main wiring with 2 run of 2.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 2.5 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface,complete all as specified and as directed. ( NOTE :- Two runs of 2.5 Sqmm pvc wire, one run of 2.5 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit)
80
10
-
... More
Supply and fix sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 4.0 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping,complete all as specified and as directed.
Note : (i) Two run of single core cable 4 sq mm and one run earth wire 2.5 sq mm will be measured as one length.(Make: RR,KEI and Finolex for copper Cable and Prestoplast/Plaza for casing/conduit)
160
10
-
... More
Supply and fixing sub main wiring with two run of single core 6 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 6.0 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping,complete all as specified and as directed.
Note : (i) Two run of single core cable 6 sq mm and one run earth wire 6 sq mm will be measured as one length.(Make: RR,KEI and Finolex for copper Cable and Prestoplast/Plaza for casing/conduit)
250
10
-
... More
S&F switch piano flush type 6 Amp single pole one way,complete all as specified and as directed.
80
10
-
... More
S&F socket flush type 6 Amp 5 Pin,complete complete all as specified and as directed.
20
100
-
... More
S&F switch socket combination 5 Pin 6 Amp universal,complete all as specified and as directed.
35
10
-
... More
S&F switch socket combination 5 Pin, 6/15 Amp universal,complete all as specified and as directed.
20
10
-
... More
S&F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body,complete all as specified and as directed.
50
10
-
... More
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings,complete all as specified and as directed.
80
10
-
... More
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schneider or Legrands).
10
10
-
... More
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour,complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
8
10
-
... More
S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 240 Volt,4 way with built in160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make: C&S/Hager/Siemens/Legrand)
2
10
-
... More
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA,complete all as specified and as directed. (Make:Hager ,Schnieder or Legrands).9380
2
10
-
... More
M&L for MCB, SP, 240V,40 Amps and 'B' series breaking capacity 10 KA ISI marked,complete all as specified and as directed.
30
10
-
... More
M&L for MCB, SP, 240V, 6 to 32 Amps and 'C' series breaking capacity 10 KA ISI marked,complete all as specified and as directed.
40
10
-
... More
M&L for MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked,complete all as specified and as directed.
10
10
-
... More
Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts,complete all as specified and as directed.
15
10
-
... More
supply and fix condencer 2/2.5 mfd suitable for ceiling fans,complete all as specified and as directed.(Make - Havells Hager/legrand)
50
10
-
... More
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket,complete all as specified and as directed.(Make - Havells Hager/legrand)
5
10
-
... More
S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr-in-charge. (Make :Crompton,Bajaj/Philips/Havells)
140
10
-
... More
S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
33
10
-
... More
S&F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size,complete all as specified and as directed by Engr-in-charge.
15
10
-
... More
S&F in repair round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and as directed by Engr-in-charge.
10
10
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I,complete all as specified and as directed.
5
10
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%