Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Spl Repair To Existing Wooden/steel Door Window For Mh Shillong And Dm And Dgo Line And Provision Of Overhead Shed And Floor Tiles Of Lawn Of Rhino Institute And Bldg No Bt-18 Of Hq 101 Area At Shillong Cantt Under Ge Shillong in East Khasi Hills, Meghalaya, with an estimated contract value of Rs. 41,23,000. The bid opening date for this tender is 05-11-2026 and the last date for bid submission is 26-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender - Meghalaya Tender
Opening Date5 Nov 2026
Closing Date26 Nov 2026
Tender Amount₹ 41,23,000
Costs
EMD
₹ 82,460Document Cost
₹ 500Tender Fee
Refer Documents
Description
Spl Repair To Existing Wooden/steel Door Window For Mh Shillong And Dm And Dgo Line And Provision Of Overhead Shed And Floor Tiles Of Lawn Of Rhino Institute And Bldg No Bt-18 Of Hq 101 Area At Shillong Cantt Under Ge Shillong
Contact
Tender Id
2026_MES_797562_1Tender No
GE/SHL/TOKEN-102 OF 2026-27Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
324
-
-
... More
S&F MS framed work such as grills, gratings, etc with ends of bars, shouldered and/ or riveted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk way, railing and framed work of water tanks and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
891
-
-
... More
S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and directed
670.79
-
-
... More
S&F for powder coated two or three track sliding (powder coating min 50 micron) anodised window and ventilator shutters side hung/sliding type without sash bar , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete all as specified and directed
197.45
-
-
... More
S&F powder coated (powder coating min 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
33
-
-
... More
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
54.12
-
-
... More
M&L for 4.8 mm thick frosted sheet glass, best quality and glazing fixed to aluminium frame n. exc 0.50 sqm frosted on one side complete all as specified and directed.
4.8
-
-
... More
M&L for 4.8 mm thick sheet glass best quality and glazing fixed to aluminium frame n. exc 0.50 sqm complete all as specified and directed.
29.25
-
-
... More
M&L for 4.8 mm thick black tinted/plain sheet glass best quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and directed.
29.25
-
-
... More
M & L for Glazed ceramic Coloured tile in vertical surfaces 350x250x7mm / 450x350x7 mm thick Set for joint free laid over and including a backing coat of 10mm thick on brick work or concrete surfaces in CM 1:4 screed, complete all as specified and directed.
52.5
-
-
... More
M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces complete all as specified and directed.
324
-
-
... More
M & L for preparation of newly plastered surfaces of walls, providing 1 mm thick of white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint with alkali resistant complete all as specified and directed.
324
-
-
... More
Complete removal existing treatment and applying 1mm thick of white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint with alkali resistant complete all as specified and directed.
383
-
-
... More
M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthectic enameled paint over one coat of red oxide primer complete all as specified and directed.
229.8
-
-
... More
Excavation in post holes each n.exc. 0.5 cum in soft/loose soil getting out returning, filling in and ramming earth or broken rubble mixed with earth around in layer n.exc. 25 cm, watering and removing surplus soil to a distance n.exc. 50 mtr and making good surface complete all as specified and directed.
16
-
-
... More
M&L Cement concrete type B-1, 1:2:4 Mix (Using 20mm graded crushed stone aggregate) as in sub base, foundation filling and mass concrete etc.complete all as specified and directed.
5.18
-
-
... More
M & L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified and directed.
20.3
-
-
... More
M&L for 100mm thick Plain Cement concrete type D-2, 1:4:8 Mix (Using 40mm graded crushed stone aggregate) as in sub base of flooring etc. complete all as specified and directed.
203
-
-
... More
M&L for non skid ceremic parking tiles drak shade 10 to 15mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but n exc 1.00 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified and directed.
236
-
-
... More
S&F steel work as in tubular , rafters, purlins, posts and similar work (round/square/rectangular shape of pipes as approved by Engr-in-charge ) trusses of semi circle/ curved shape up to height 6 mtr including post special shaped washers, gusset plates etc complete using ERW or induction butt welded tubes conformining to IS 1161-1998 garde St-240 complete all as specified and directed.
2900
-
-
... More
M/L precast cement concrete block masonry with solid blocks, using cement concrete 1:3:6 Mix, type C1 (Using 20 mm graded crushed stone aggregate) exc 10 cm in width and settings in CM 1:6 complete all as specified and directed.
3
-
-
... More
M&L for PCC 1:3:6 Mix, type C-2 (using 40mm graded crushed stone aggregate) as in surface channel and drains complete all as specified and directed.
5
-
-
... More
Extra forming faor fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds , mitred/stopped ends rtc all as specified and directed.
90
-
-
... More
S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof covering / cladding including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, complete all as specified and directed.
252
-
-
... More
S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tenssile strength of 550 Mpa as in roof covering including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed.
10
-
-
... More
M&L for 15 mm thick plaster in cm (1:4) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed.
10
-
-
... More
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, PVC conduit on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch.
32
-
-
... More
Description all as per Srl item No 30 here in before but for socket outlet point 5 Amp on same board.
2
-
-
... More
Description all as per Srl item No. 30 here in before but for socket outlet point 5 Amp on Independent board.
6
-
-
... More
Description all as per serial item No 30 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified and directed.
4
-
-
... More
Supply and fixing modular switch 1 way 6 A with cover plate and frame 230/250 volt , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed.
40
-
-
... More
Supply and fixing modular switch 1 way 16 A with cover plate and frame230/250 volt , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed.
4
-
-
... More
Supply and fixing modular sockets with cover plate and frame 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed.
8
-
-
... More
Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module with cover plate and frame 230/250 Volts, 50 Hz , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed.
4
-
-
... More
Supply and fixing LED batten with Extruded aluminium for proper heat dissipation 20/22 watt with CCT 3000K/6000K (Warm white/Cool white). The Driver must be integrated electronic driver with inbuilt 4KV Surge protection. Lumen efficancy must be 100 Lumens per watt for Cool white and 90 Lumene per watt for warm white Jaquar Cat part No. - BTI - WHT-LGLZ01X020XC/XW or equivalent in Havells/ Bajaj
32
-
-
... More
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed.
32
-
-
... More
Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. . Notes : (i) MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . (ii) Copper thimble shall be used for connection of cable .
1
-
-
... More
Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact including taking down old unserviceable one including MCBs complete all as specified and directed.
1
-
-
... More
Supply and fix MCB TPN 40-100 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed.
1
-
-
... More
Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
1
-
-
... More
Supply and fix MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's complete all as specified and directed.
10
-
-
... More
M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.
Notes: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
40
-
-
... More
Material and labour for earthing complete with galvanized Steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 mm x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed.
1
-
-
... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and directed.
55
-
-
... More
Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of any dismeter in soft/loose soil and getting out complete all as specified and directed
13
-
-
... More
Returning, filling in, including spreadking levelling watering and well ramming in layers not exc 25 cm thick soft/loose soil complete all as specified and directed
11.5
-
-
... More
Removing excavated material at a distance n exc 50m and deposited where directed at a level not exc 1.5 above the starting point for soft/lose soil complete all as specified and directed
1.5
-
-
... More
M & L for sand filing in treances for providing sand cushion for protection of UG cable complete all as specified and directed.
4
-
-
... More
Supply and laying of sub class B bricks locally available alying perpendicular of UG cable complete all as specified and directed.
0.45
-
-
... More
M&L for fixing in replacement GI tubing 50 mm bore light grade, on poles, on walls, under floors, road crossing including fittings as reqd at site complete all as specified and directed.
10
-
-
... More
Note for all items: If in BOQ, any item found repeated and contractor quotes different rates for the same, the lesser rate quoted by the contractor shall be admissible for payment and no claim of contractor, whatsoever, on this account shall be entertained by the Department.
-
-
-