Military Engineer Services Tender
View complete overview of Meghalaya MES Tender
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/replacement Of Sewage Line, Manholes, Cover Slabs And Connected Misc Works In Zone I And Cleaning And Desilting Of Septic Tank, Manholes, Soak Well And Sewage Line And Connected Misc Works In Zone I And Ii
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_707738_1Tender No
8908/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Cleaning and desilting of septic tanks upto 201-300 users, of any size & depth from solid liquid/liquid mud etc and removing sludge outside of Defence land including pumping out liquid qnd liquid sludge with pumping arrangements, labour and machine as required complete all as specified and directed by Engr-in-charge.
5
100
500
... More
Removing plants/herbs grown on duct/wall portion, SWR pipes joint area in multistoried buildings of any storeyed. Cleaning with steel brush and rubbish down all dirt, mud and shabby materials from the SWR pipe joints & duct/wall portion complete and applied neat cement slurry/cement mortar on the leakages of SWR pipe joints /vertical stacks and applying one coat of cement based paints on duct wall portion complete all as specified and directed by Engr-in-charge.
600
100
60000
... More
Cleaning and desilting of soakage well of size 3.0m internal dia and depth upto 4.5m from solid liquid/liquid mud, etc. and removing sludge outside of Defence land complete including pumping out liquid and liquid sludge with pumping arrangements, labour and machine as required complete all as specified and directed by Engr-in-charge.
Note : The quoted rate is deemed to be inclusive of refilling old usable brick obtained from cleaning of sewage well.
15
100
1500
... More
M&L for filling new sewer bricks in soakage well complete all as specified and directed.
60
100
6000
... More
Cleaning and desilting of manholes of size not exceeding 1.2m x 1.20m & depth upto 1.5m from solid liquid/liquid mud etc. and removing sludge outside of Defence land complete including pumping out of liquid and liquid sludge with pumping arrangements all as specified and directed by Engr-in-charge.
1240
100
124000
... More
Cleaning and desilting of manholes of size not exceeding 1.2m x1.20m & depth exceeding 1.5m but not exceeding 3.0 m from solid liquid/liquid mud etc. and removing sludge outside of Defence land complete including pumping out liquid and liquid sludge with pumping arrangements labour and machine as requirement complete all as specified and directed by Engr-in-charge.
150
100
15000
... More
Excavating in trenches, n.exc 1.50 m wide & n.exc 1.5 m in depth; for foundation etc. or for shaft, wells, cesspits, manholes, piers holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
110
100
11000
... More
All as per item No 10 here in before but depth exc 1.50 m but not exceeding 3.00 m complete all as specified and directed.
33
100
3300
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
55
100
5500
... More
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.50m above the starting point including spreading and levelling complete all as specified and directed.
88
100
8800
... More
Demolition and breaking up drain pipes 150mm bore (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
520
100
52000
... More
Supply and fixing of PVC (SWR) pipe 150 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors cement complete all as specified and directed.
150
100
15000
... More
Supply and laying of 160 mm Nominal diameter, HDPE of pressure rating of PN 4 as per IS 14333:1996 for sewage line in any length laid in trenches complete all as specified and directed.
370
100
37000
... More
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C2 for 150 mm bore of pipe complete all as specified and directed.
511
100
51100
... More
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
10
100
1000
... More
Demolition of precast cement concrete block walling set in cement mortar complete all as specified and directed.
51
100
5100
... More
M&L for Pre cast cement concrete block masonry with solid block, (1:3:6) type C1 (using 20mm graded stone aggregate), exc.10 cm in width and setting in cement mortar 1:6 complete all specified and directed.
51
100
5100
... More
M&L for 15mm thick rendering in CM 1:4 on internal/external wall surfaces finished even and smooth witout using extra cement with using WPC as per manufacturing instruction complete all as specified and directed. Note: WPC shall be measured and paid separetely.
722
100
72200
... More
Supply only Water proofing compound
201.0048
100
20100.48
... More
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed.
34.6
100
3460
... More
M&L for cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed
23.95
100
2395
... More
M&L for PCC 1:2:4 type B0 (using 12.50 mm graded stone aggregate) as in coping benching/haunching, slightly rounded or chamfred angle and throating etc complete all as specified and directed.
3.02
100
302
... More
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm dia of pipe complete all as specified and directed.
45
100
4500
... More
M&L for precast RCC type B-1, 1:2:4 (using 20 mm graded aggregate ) as in cover slab set in CM 1:4 including necessary form work if required complete all as specified and directed.
10
100
1000
... More
M&L for TMT bars 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9 mm dia complete all as specified and directed.
700
100
70000
... More
M&L for MS deformed or twisted round bars 10mm dia and over, cut to length, bent to shape as required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
100
100
10000
... More
Taking down soil pipe/rainwater pipes (any size or pattern ), including all fittings, heads, shoes, bends, swannecks, etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
165
100
16500
... More
S&F PVC (SWR) pipe 110 mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
70
100
7000
... More
S&F PVC (SWR) pipe 110 mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
95
100
9500
... More
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed.
82
100
8200
... More
S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
82
100
8200
... More
S&F PVC (SWR) 110mm bore bends with access door any radius complete all as specified and directed.
41
100
4100
... More
S&F PVC (SWR) 110mm bore junction single (single T) equal or un equal complete all as specified and directed.
42
100
4200
... More
S&F PVC (SWR)110mm bore junction single (single T) equal or un equal provided with access door complete all as specified and directed.
42
100
4200
... More
S&F PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed.
44
100
4400
... More
S&F PVC (SWR) junction double, (double T) provided with access door equal or unequal complete all as specified and directed.
44
100
4400
... More
Surface dressing not exceeding 15 cm deep and getting out in loose/soft soil complete all as specified and directed.
700
100
70000
... More
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15cm thickness (below or above ground level) and removing debries from site of work complete all as directed by the Engineer-in-Charge.
8
100
800
... More
M & L for PCC (1:5:10), type E-2 (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.
8
100
800
... More
M&L for laying/spreading of sand filling to precast concrete interlocking paver block including watering & consolidating complete all as specified and directed.
2.5
100
250
... More
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, jointed with grey cement and no pigment complete all as specified and directed.
100
100
10000
... More
M&L for cement concrete M-15 (Nominal mix) in edging of path (interlocking paver) and the like including weathering slightly rounded or chamfered angles as directed including form work and finishig all exposed surfaces, complete all as specified and directed.
3.66
100
366
... More
M & L for Chequered cement concrete tiles with mixture of white and grey cement in equal portions and no pigment, set over screed bed or bedding layer of cemrnt mortar of 1:4 20mm thick for laying floor finishes, jointed and pointed in neat cement slurry in floors complete all as specified and directed.
90
100
9000
... More
M&L for 75 mm thick cement concrete type C2 1:3:6 using 20 mm graded aggregate as in plinth protection finished fair and even without using extra cement complete all as specified and directed.
75
100
7500
... More
M&L for cement concrete type C2 1:3:6 using 40 mm graded aggregate in surface channels and drains complete all as specified and directed.
2
100
200
... More
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
212
100
21200
... More
Schedule of Credit
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%