Assam Rifles Tender
View complete overview of Meghalaya Assam Rifles Tender
Assam Rifles Tender
Eprocure
Opening Date4 Jun 2024
Closing Date24 Jun 2024
Tender Amount₹ 15,41,100
Costs
EMD
₹ 30,900Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMHA_809883_1Bid Award Id
ViewTender No
ENG/III-235/2024-25/35 dated 04 Jun 2024Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de
rived from natural sources)
8.84
-
-
Reinforced cement concrete work in beams, suspended floors, roofs
having slope up to 15° landings, balconies, shelves, chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
23.35
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass
concrete
24
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
61.44
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
51.7
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access
platform
88.2
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more
758.07
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
3032.3
-
-
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand
20.78
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
159.9
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand)
61.71
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
159.9
-
-
Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
61.71
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) Two or more coats on new work
6.05
-
-
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 25 mm Thick
26.21
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
2.52
-
-
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
16.2
-
-
Providing and fixing bright finished brass tower bolts (barrel type) with
necessary screws etc. complete :200x10 mm
2
-
-
Providing and fixing bright finished brass handles with screws etc.
complete: 125 mm
2
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade, with nuts and screws
etc. complete 250x16 mm
1
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
3
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
30
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required.
40
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required of 5 to 10 way complete including modular base cover and plate
2
-
-
Supply of LED tube light fitting 36 Watt Make-Phillips/ Havells/Bajaj
4
-
-
Supplying, Laying, spreading and compacting stone aggregate of specified sizes 63 mm to 45 mm size stone aggregate specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density
5.07
-
-
Providing And Laying in Position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1 cement : 4 Coarse sand 8: grade stone aggregate 40 mm nominal size derived from natural sources)
4.1
-
-
Providing and laying factory made chamfered edge cement concrete paver blocks in footpath, park, lawns, drive ways or light traffic parking etc of required srength, thickness & size/shape made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compcted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand ctting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Change. 80 mm thick CC paver block of M-30 grade with approved colour design and pattern.
41
-
-
Providing and laying APP (AtacticPolypropylene Polymer) modifiedprefabricated five layer 3 mm thick water proofing membrane, blackfinished reinforced with non-woven polyester matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 litre/sqm bythe same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer ofmembrane shall be laid using Butane Torch and sealing all jointsetc, and preparing the surface complete. The vital physical andchemical parameters of the membrane shall be as under : Jointstrength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane with 3 mm thick.
52.2
-
-
Supplying, Laying, spreading and compacting stone aggregate of specified sizes 63 mm to 45 mm size stone aggregate specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density
6.15
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
12.83
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements