Regional Institute Of Medical Sciences Tender
Take tender evaluation notes for Manipur RIMS Tender
Regional Institute Of Medical Sciences - RIMS Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Mar 2025
Closing Date27 Mar 2025
Tender Amount₹ 72,67,675
Costs
EMD
₹ 1,45,354Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_RIMS_853352_1Bid Award Id
ViewTender No
4/127/24-CWS(RIMS)Tender Authority
Regional Institute Of Medical Sciences ViewPurchaser Address
-Website
http://http://www.rims.edu.in/secure/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
16X 2 HP (Inclusive of ODU Refnet)
32
-
-
... More
VRV INDOOR UNITS - FLOOR MOUNTED AIR HANDLING UNIT
Supply, Installation, Testing & Commissioning of sheet metal sectionalised construction double skin air handling units with 50 mm thick injected PUF of density not less than 40 Kg/CuM with thermal break profile. The air handling units shall be complete with pre-filter section with synthetic fibre filters and MERV-13 & MERV 8 filter, coil section with multi rows deep DX cooling coil of copper tube & aluminium fin construction, fan section complete with EC fan suitable for total static pressure as detailed below, IE-02 motor, insulated stainless steel drain pan and vibration isolation arrangement all complete as per specifications. AHUs shall be selected for a maximum face velocity of 400 FPM. The units shall be compatible with VRF outdoor units.
-
-
-
... More
The unit shall be supplied with electronic expansion valve/s (Dx), thermostat/s, control wiring & all accessories as required for completing installation. Fan outlet velocity shall not exceed 2000 FPM (10.1 MPS). The unit/s shall be be provided with factory fabricated plenum on filter side, with access doors /panels, for duct termination. AHUs shall be of following design parameters: Control kit for AHU's from VRF supplier shall be supplied for installation in AHU. AHU kit for connecting the Cooling coils with the VRF Outdoor unit complete with Electronic Expansion valve, Sensors, wired remote controller and PCB etc. as required to be included in cost.
-
-
-
... More
a) Capacity SP : 3300 Cfm, SP : 65 mm WG, No. of rows : 4, Motor rating (HP) : Suitable rating, Ref. load : 10 TR
1
-
-
... More
b) Capacity SP : 5200 Cfm, SP : 65 mm WG, No. of rows : 4, Motor rating (HP) : Suitable rating, Ref. load : 13TR
1
-
-
... More
Indoor Unit Cassette Type
-
-
-
... More
Supply installation,testing and commissioning of following minimum capacity 4 way flow VRV/VRF cassete type Indoor ceiling mounted unit equiped with synthetic washable media pre filter,fan section with low noise fan/dynamically balance blower,multispeed motor ,coil section with DX copper coil,electronic expanssion valve,outer cabinet,drain pump,grill,necessary supports ,vibration isolation,cord less remote etc.suitable for operation on singl e phase 230+10% volt, 50 HZ, AC supply, complete,as reqd. the unit shall have automatic force shut down provision in case of fire on receiving signel from BMS system .the coolingcapacity of indoor unit will be at air inlet condition of 27 degree celcius DB and 19 degree Celcius WB temperature.
-
-
-
... More
1 TR
1
-
-
... More
1.6 TR
3
-
-
... More
2.8 TR
2
-
-
... More
3.2 TR
2
-
-
... More
(Copper Refrigerent piping)
-
-
-
... More
SITC including vaccumiazization and nitrogen testing of following nominal size of soft/hard drawn copper refrigerent piping for VRF/VRV system complete with fittings,with suitable adjustable ring type hanger supports,joining/brazing including accessories,insulated with XPLE class-O tubular insulation /with class-O closed cell elestometric nitrile rubber tubular sleeve sections of specific thickness as given below for suction and liquid lines,all accessories as pewr specification etc..as reqd.
-
-
-
... More
a) 12.7mm dia (OD) (soft drawn) with tube thickness 1.2mm with 19 mm thick insulation.
100
-
-
... More
b) 6.4mm dia (OD) (soft drawn) with tube thickness 1.2mm with 19 mm thick insulation.
100
-
-
... More
c) 9.5 mm dia (OD) (soft drawn) with tube thickness 1.2mm with 19 mm thick insulation.
160
-
-
... More
d) 15.9 mm dia (OD) (hard drawn) with tube thickness 1.2mm with 19 mm thick insulation.
160
-
-
... More
e) 19.6mm dia (OD) (hard drawn) with tube thickness 1.2mm with 19 mm thick insulation.
150
-
-
... More
f) 22.2mm dia (OD) (hard drawn) with tube thickness 1.2mm with 20 mm thick insulation.
100
-
-
... More
g) 28.6mm dia (OD) (hard drawn) with tube thickness 1.2mm with 21 mm thick insulation.
120
-
-
... More
h) 34.9mm dia (OD) (hard drawn) with tube thickness 1.2mm with 22 mm thick insulation.
90
-
-
... More
i) 41.3mm dia (OD) (hard drawn) with tube thickness 1.2mm with 23 mm thick insulation.
90
-
-
... More
Supply and Application of pvc 'A' Class Drain Pipe with 6mm thick closed cell elastomeric insulation in tubing form for condensate drain piping as per the specifications.
-
-
-
... More
a) 25mm dia
180
-
-
... More
b) 32mm dia
110
-
-
... More
Supply , installation , balancing and commissioning of site fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , supports etc as per approved drawings and specifications of following sheet thickness complete as required.
-
-
-
... More
a) Thickness 0.63 mm sheet
180
-
-
... More
b) Thickness 0.80 mm sheet
295
-
-
... More
c) Thickness 1.00 mm sheet
115
-
-
... More
Supply and charging of zero ODP refrigereant R410A
100
-
-
... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core as reqd.
10
-
-
... More
Supplying , fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core as reqd.
10
-
-
... More
Supplying installation, testing & commissioning of GI volume conntrol duct damper complete with neoprene rubber gaskets , nuts , bolts,screw linkages , flanges etc as per specificaion.
5
-
-
... More
Supplying and fixing of acoustic lining of supply air duct and plenum with 25mm thick resin bonded glasswool having density of 32 Kg/m³ with 25mmX25mm GI suction of 1.25 mm thick, at 600 mm centre to centre cover with reenfore plas tic tissue paper and 0.5mm thick perforated alluminium sheet fixed to inside surface of duct with cadmium plated nuts,bolts, stick pins, CPRX compound etc. complete as reqd and as per specification.
116
-
-
... More
Supplying and fixing of following thickness duly laminated alluminium foil of mat finish closed cell nitrile rubber (Class O) insullation on existing duct after applying suitable addhesshive for nitrile rubber . the joints shall be shealed with 50 mm wide and 3 mm thick self adhessive nitrile rubber tape inssulation complete as per specification and as reqd..above valves should have pressure rating of 25 Bar minimum.
-
-
-
... More
a) 19 mm
575
-
-
... More
AHU UNIT (DX TYPE) For OT 1 & OT 2
-
-
-
... More
Supplying, installation, testing and commissioning of 5.5 TR, programmable microprocessor based, Air-cooled Package Type DX units complete with condensing unit, scroll compressor, air-cooled condenser with fan and evaporator,interconnecting refrigerant piping with indoor and outdoor units,pre charge refrigerant necessary insulation. Cooling & Humidification controls and interlocking with control wiring etc. complete with following and as per specifications and requirement.
-
-
-
... More
Indoor Unit-for OT 1 & OT 2.
-
-
-
... More
a) Fan Section and canvass connection (Double Skin Type). b) Centrifugal Blower with Capacity of 2200 CFM and 125mm Static Pressure.. c) Cooling Coil Section/s with 5.5 TR cooling coil/s as per specifications. d) Pre Filter with filter section as required. e) Drain Pan and Drain Connection. f) Drive motor, Drive arangement guard etc. g) Necessary vibration isolator and supporting arrangements. h) Fresh air intake arrangement, necessary water drain and air purge valve wherever required etc.
2
-
-
... More
Outdoor Unit DX TYPE 5.5TR
-
-
-
... More
a) Suitable Air Cooled Type Condenser with Aluminium Fins & Copper Tube Coilsfor above indoor unit. b) Scroll Type Hermetically sealed Comperssor. c) Suitable condenser fans for the condensing unit. d) necessary hard drawn copper refrigerant piping per circuit with kinnifoam insulation along with clamps,supports,fittings such as bends,tees,reducers etc complete as per specfications and requirement.
2
-
-
... More
Supply, installation, testing & commissioning of strip heater.
-
-
-
... More
Capacity 2.0 KW 2 bank
2
-
-
... More
Supply, Installation, testing and commissioning of Corded remote controls, sensor,humidifier sensor as required for controling the AHU Unit
2
-
-
... More
Supply, fabrication, installation and testing of site fabricated aluminium ducts in accordance with the approved shop floor drawing and specifications. Material should confirm to IS 737 latest edition.
-
-
-
... More
22 gauge
75
-
-
... More
20 gauge
70
-
-
... More
Supply of XLPE Insulated Armoured Copper Power Cables Conductor ,PVC Innersheathed with suitable upto 1100V Grade As Per IS 7098(Part 1) 1988
-
-
-
... More
a) 4 x 16 sq mm
210
-
-
... More
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface /recessed steel conduits as reqd.
-
-
-
... More
i)2X4sq.mm +1X4sq mm earth wire
293
-
-
... More
Supply and fixing electrical panel compact size suitable for inddor having MCCB 400 Amp Bus -Bar chamber with 4 strips copper bus bar of length 300mm suitable for 400 amp capaciy complete with all accessories with connection earthing the body etc as reqd.
1
-
-
... More
Earthing with copper plate 600mmX600mmX 3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal/coke and salt as reqd.
2
-
-
... More
providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as reqd.
200
-
-
... More
Supplying and fixing following way,single pole and neutral,sheet steel,MCB distribution board 240v,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar interconnections,power painted including earthing etc.as reqd.(but without MCB/RCCB/Isolator)
-
-
-
... More
16 way,double door
2
-
-
... More
Supplying and fixing 5A to 32 amp rating.240/415V,10KA,''C'' curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commisioning etc.as reqd.
-
-
-
... More
single pole
24
-
-
... More
single pole & neutral
2
-
-
... More
MS perforated cable tray Hot dripped Galvanized 300X 50X 1.6 mm as reqd.
190
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements