Regional Institute Of Medical Sciences Tender
View complete overview of Manipur RIMS Tender
Regional Institute Of Medical Sciences - RIMS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2023
Closing Date25 Oct 2023
Tender Amount₹ 13,96,242
Costs
EMD
₹ 27,925Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_RIMS_775303_1Bid Award Id
ViewTender No
184/2023-24/RIMS/ImphalTender Authority
Regional Institute Of Medical Sciences ViewPurchaser Address
-Website
http://http://www.rims.edu.in/secure/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Boring, providing and installation bored cast-in-situ reinforced cement concrete
piles of grade M-25 of specified diameter and length below the pile cap, to carry
a safe working load not less than specified, excluding the cost of steel
reinforcement but including the cost of boring with bentonite solution and
temporary casing of appropriate length for setting out and removal of same
and the length of the pile to be embedded in the pile cap etc. by percussion
drilling using Direct mud circulation (DMC) or Bailer and chisel technique by
tripod and mechanical Winch Machine all complete, including removal of
excavated earth with all its lifts and leads (length of pile for payment shall be
measured up to bottom of pile cap).
-
-
-
450 mm dia piles
12
-
-
Cement concrete for re inforced concrete in pile cap complete as per drawing and technical specification
-
-
-
RCC Grade M25
0.72
-
-
Dismantling of Reinforced concrete pile head complete as per drawing and technical specification
1
-
-
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
21.29
-
-
Demolishing cement concrete manually/ by mechanical means anddisposal of material within 50 metres lead as per direction ofEngineer in charge.
-
-
-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
0.08
-
-
Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceablematerialwithin 50 metres lead as per direction of Engineer-in-charge.
-
-
-
In Cement mortar
12.53
-
-
Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within50 metres lead :
-
-
-
Of area 3 sq. metres and below
10
-
-
Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead.
-
-
-
For thickness of tiles above 10 mm and upto 25 mm
97.67
-
-
Demolishing R.C.C. work by mechanical means and stockpiling atdesignated locations and disposal of dismantled materials up to alead of 1 kilometre, stacking serviceable and unserviceablematerial separately including cutting reinforcement bars.
2.81
-
-
Dismantling old plaster or skirting raking out joints and cleaningthe surface for plaster including disposal of rubbish to thedumping ground within 50 metres lead.
26.91
-
-
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with afloating coat of neat cement.
92.25
-
-
Extra for providing and mixing water proofing material in cementconcrete work @1 kg per 50 kg of cement.
117.64
-
-
Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shuttering -
-All work upto plinth level:
-
-
-
1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mmnominal size)
19.73
-
-
1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 40 mmnominal size)
14.87
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed of dry brick ballast 40mm nominal size wellrammed and consolidated and grouted with fine sand includingfinishing the top smooth.
27.3
-
-
Reinforced cement concrete work in walls(anythickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement :
-
-
-
1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
1.62
-
-
Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair casesabove plinth level upto floor five level, excluding the cost ofcentering,shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size).
-
-
-
1:1.5:3(1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominial size).
0.32
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :
-
-
-
1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.72
-
-
Steel reinforcement for RCC work including straightening,cutting, bending, placing in position and binding all complete TMT bars
-
-
-
Thermo-Mechanically Treated bars
2698.82
-
-
Centering and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
31.98
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts.
3.24
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick.
9
-
-
Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm thick.
5.4
-
-
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
21.6
-
-
Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in foundation and plinth in:
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
2.7
-
-
Half brick masonry with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in
-
-
-
Cement mortar 1 : 3 (1 cement : 3 coarse sand)
73.95
-
-
Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within50 metres lead :
-
-
-
Of area 3 sq. metres and below
10
-
-
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5sqm and under,including cutting the patch in proper shape, rakingout joints and preparing plastering the wall surface with whitecement based polymer modified self curing mortar, includingdisposal of rubbish, all complete as per the direction of Engineer-In-Charge.
18.36
-
-
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.
-
-
-
Double charge vitrified tile polished finish of sizeSize of Tile 600 x 600 mm
98.09
-
-
Providing and fixing 1st quality ceramic glazed wall tilesconforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades exceptburgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thickbed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing inwhite cement mixed with pigment of matching shade complete.
6.18
-
-
Providing 40x5 mm flat iron hold fast 40 cm long including fixing toframe with 10mm diameter bolts, nuts and wooden plugs andembedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize)
32
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :
-
-
-
Local best quality Uningthou wood
0.23
-
-
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
-
-
-
Local best quality Tolhao wood.
-
-
-
35 mm thick shutters
1.89
-
-
Providing and fixing panelling or panelling and glazing in panelledor panelled and glazed shutters for doors, windows and clerestorywindows (Area of opening for panel inserts excluding portioninside grooves or rebates to be measured). Panelling for panelledor panelled and glazed shutters 25 mm to 40 mm thick :
-
-
-
4 mm thick glass panes
3.24
-
-
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge
2
-
-
Providing and fixing bright finished brass tower bolts (barreltype) with necessary screws etc. complete
-
-
-
i) 250 x 10 mm
16
-
-
Providing and fixing aluminium sliding door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete :
-
-
-
i)300 x 16 mm
2
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing thesurface smooth including necessaryrepairs to scratches etc. complete.:
398.8
-
-
12 mm cement plaster of mix:
-
-
-
1:4 (1 cement : 4 fine sand)
61.7
-
-
15 mm cement plaster on rough side of single or half brick wall ofmix:-
-
-
-
1:4 (1 cement : 4 fine sand)
35
-
-
Providing and applying white cement based putty of averagethickness 1mm,of approved brand and manufacturer, over theplastered wall surface to prepare the surface even and smoothcomplete.
303.65
-
-
Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm.
26.91
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
-
-
-
Water thinnable cement primer
398.8
-
-
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications :
-
-
-
Two or more coats applied @ 1.25 ltr/10 sqm. over and includingone coat of Special primer applied @0.75 ltr/10 sqm.
398.8
-
-
Painting wood work with Deluxe Multi Surface Paint of requiredshade. Two or more coat applied @0.90 ltr/10 sqm over an undercoat of primer applied @0.75 ltr/ 10 sqm of approved brand ormanufacture
11.95
-
-
ProvidingandfixingP.V.C.wastepipeforsinkorwashbasinincluding P.V.C. waste fittings complete.
-
-
-
Semi rigid pipe
-
-
-
32 mm dia
1
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required:
-
-
-
White Vitreous China Wash basin size 630x450 mm with a pair of15 mm C.P.brass pillar taps
1
-
-
Providing and fixing in position collapsible steel shutters withvertical channels 20xl0x2mm and braced with flat iron diagonals20x5mm size with top and bottom rail of T-iron 40x40x6mm with40mm dia, steel pulleys complete with bolts, nuts, lockingarrangement, stoppers, handles, including applying a priming coatof approved steel primer.
3.6
-
-