Regional Institute Of Medical Sciences Tender
View complete overview of Manipur RIMS Tender
Regional Institute Of Medical Sciences - RIMS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date21 Feb 2024
Closing Date4 Mar 2024
Tender Amount₹ 7,57,923
Costs
EMD
₹ 15,158Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RIMS_796678_1Bid Award Id
ViewTender No
254/2023-24/RIMS/ImphalTender Authority
Regional Institute Of Medical Sciences ViewPurchaser Address
-Website
http://http://www.rims.edu.in/secure/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -
-All work upto plinth level:
-
-
-
1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mmnominal size)
0.56
-
-
1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
4.26
-
-
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :
-
-
-
1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
1.46
-
-
BrickworkwithIstclasscommonburntclayF.P.S.(nonmodular)bricks in foundation and plinth in:
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
2.16
-
-
Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair casesabove plinth level upto floor five level, excluding the cost ofcentering,shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size).
0.12
-
-
Centering and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
10.5
-
-
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Above Plinth level
-
-
-
Thermo-Mechanically Treated bars
183.66
-
-
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
20.54
-
-
Half brick masonry with Ist class common burnt clay F.P.S.(nonmodular)bricks in superstructure above plinth level upto floor V level in
-
-
-
Cement mortar 1 : 3 (1 cement : 3 coarse sand)
44.28
-
-
12 mm cement plaster of mix:
-
-
-
1:4 (1 cement : 4 fine sand)
44.28
-
-
15 mm cement plaster on rough side of single or half brick wall of mix:-
-
-
-
1:4 (1 cement : 4 fine sand)
44.28
-
-
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with afloating coat of neat cement.
-
-
-
20 mm cement plaster.
9
-
-
Providing and fixing aluminium work for doors, windows,ventilators and partitionswith extruded built up standard tubularsections/ appropriate Z sections and other sections of approvedmake conforming to IS: 733 and IS : 1285, fixed with rawl plugs andscrews or with fixing clips, or with expansion hold fastenersincluding necessary filling up of gaps at junctions, at top, bottomand sides with required EPDM rubber/ Neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle,Aluminium snap beading for glazing / panelling, C.P. brass /stainless steelscrews, all complete as per architectural drawingsand the directions of Engineer-in-charge. (Glazing and panelling tobe paid for separately):
-
-
-
For fixed portion
-
-
-
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
100.92
-
-
For shutters of doors, windows & ventilators including providing andf ixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).
-
-
-
Anodised aluminium (anodised transparent or dyed to requiredshade according to IS: 1868, Minimum anodic coating of grade AC15)
32.7
-
-
Providing and fixing 12mm thick prelaminated particle board
20.05
-
-
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backerrod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
-
-
-
Upto 5mm depth and 5 mm width
13.2
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
-
-
-
With float glass panes of 4.0 mm thickness
6.48
-
-
Steel work in builtup tubular(round,square orrect angular tubesetc.) trusses etc.,including cutting,hoisting fixing in position and applying a priming coat of approved steel primer,including welding and bolted including special shaped washers etc.complete.
-
-
-
Hot finished welded type tubes
1000.09
-
-
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.
-
-
-
Double charge vitrified tile polished finish of size
-
-
-
Size of Tile 600 x 600 mm
18.75
-
-
Providing and fixing 1st quality ceramic glazed wall tilesconforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades exceptburgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thickbed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing inwhite cement mixed with pigment of matching shade complete.
19.8
-
-
Providing and applying white cement based putty of averagethickness 1mm,of approved brand and manufacturer, over theplastered wall surface to prepare the surface even and smoothcomplete.
65.16
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
-
-
-
Water thinnable cement primer
84.96
-
-
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications :
-
-
-
Two or more coats applied @ 1.25 ltr/10 sqm. over and includingone coat of Special primer applied @0.75 ltr/10 sqm.
65.16
-
-
Wall painting with acrylic emulsion paint, having VOC (VolatileOrganic Compound ) content less than 50 grams/ litre, of approvedbrand and manufacture, including applying additional coatswherever required, to achieve even shade and colour.
-
-
-
Two coat
84.96
-
-
Providing and fixing aluminium handles, ISI marked,anodised(anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour or shade with necessaryscrews etc. complete :
-
-
-
125 mm
2
-
-
Providing and fixing aluminium sliding door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete :
-
-
-
250x16 mm
2
-
-
Providing and fixing aluminium tower door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete :
-
-
-
i)300 x 16 mm
1
-
-
Providing and fixing IS : 12817 marked stainless steel butt hinges(heavy weight) with stainless steel screws etc. complete :
-
-
-
125x64x2.50 mm
4
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
-
-
-
External work
-
-
-
25 mm nominal outer dia Pipes
30
-
-
50 mm nominal outer dia Pipes
30
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with sealring conforming to IS :5382 leaving 10 mm gap for thermalexpansion, (i) Single socketed pipes
-
-
-
75 mm diameter
25
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap for thermal expansion
-
-
-
Single tee with door
-
-
-
75x75x75 mm
15
-
-
Bend 87.5
-
-
-
75 mm bend
15
-
-
Providing and fixing brass bib cock of approved quality :
-
-
-
25 mm nominal bore
20
-
-
Providing and placing on terrace (at all floor levels) polyethylenewater storage tank, IS : 12701 marked, with cover and suitablelocking arrangement and making necessary holes for inlet, outletand overflow pipes but without fittings and the base support fortank.
4000
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements