Regional Institute Of Medical Sciences Tender
View complete overview of Manipur RIMS Tender
Regional Institute Of Medical Sciences - RIMS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2024
Closing Date23 Oct 2024
Tender Amount₹ 35,46,940
Costs
EMD
₹ 70,939Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Providing Requisite Requirements For Commissioning Of New Laundry Building At Rims, Imphal.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RIMS_829945_1Bid Award Id
ViewTender No
42/2024-25/RIMS/ImphalTender Authority
Regional Institute Of Medical Sciences ViewPurchaser Address
-Website
http://http://www.rims.edu.in/secure/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -
-All work upto plinth level:
-
-
-
1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mmnominal size)
35.15
-
-
1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
29.31
-
-
Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level :
-
-
-
1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
6.48
-
-
Reinforced cement concrete work in walls (anythickness) ,including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level excluding cost of centering, shuttering, finishing and reinforcement :
-
-
-
1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
10.13
-
-
BrickworkwithIstclasscommonburntclayF.P.S.(nonmodular)bricks in foundation and plinth in:
-
-
-
Cement mortar 1:4 (1 cement : 4 coarse sand)
6.51
-
-
Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair casesabove plinth level upto floor five level, excluding the cost ofcentering,shuttering, finishing and reinforcement with 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size).
0.3
-
-
Centering and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
42.34
-
-
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
180
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts.
1.3
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
9
-
-
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Above Plinthlevel
-
-
-
Thermo-Mechanically Treated bars
2293.83
-
-
Half brick masonry with Ist class common burnt clay F.P.S.(nonmodular)bricks in superstructure above plinth level upto floor V level in
-
-
-
Cement mortar 1 : 3 (1 cement : 3 coarse sand)
67.62
-
-
12 mm cement plaster of mix:
-
-
-
1:4 (1 cement : 4 fine sand)
131.07
-
-
15 mm cement plaster on rough side of single or half brick wall ofmix:-
-
-
-
1:4 (1 cement : 4 fine sand)
82.47
-
-
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with afloating coat of neat cement.
-
-
-
20 mm cement plaster.
190
-
-
Providing and fixing aluminium work for doors, windows,ventilators and partitionswith extruded built up standard tubularsections/ appropriate Z sections and other sections of approvedmake conforming to IS: 733 and IS : 1285, fixed with rawl plugs andscrews or with fixing clips, or with expansion hold fastenersincluding necessary filling up of gaps at junctions, at top, bottomand sides with required EPDM rubber/ Neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle,Aluminium snap beading for glazing / panelling, C.P. brass /stainless steelscrews, all complete as per architectural drawingsand the directions of Engineer-in-charge. (Glazing and panelling tobe paid for separately):
-
-
-
For fixed portion
-
-
-
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
20.6
-
-
For shutters of doors, windows & ventilators including providing andf ixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately).
-
-
-
Anodised aluminium (anodised transparent or dyed to requiredshade according to IS: 1868, Minimum anodic coating of grade AC15)
25.12
-
-
Providing and fixing 12mm thick prelaminated particle board
3.78
-
-
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.
-
-
-
In stringers, treads, landing etc. of staircases including use of chequered plate wherever required, all complete.
1840.08
-
-
Ingrating, frames, guardbar, railing, brackets, gates and similar works.
278.48
-
-
Steel work in builtup tubular (round, square or rectangular tubes etc.)trussesetc.,including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete.
-
-
-
Hot finished welded type tubes
3555.66
-
-
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)with zinc coating 120 grams per sqm as per IS: 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto12 metre or as desired by Engineer-in charge. The sheet shall befixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
-
-
-
Precoated galvanised iron profile sheets 0.40 mm thick
319.05
-
-
Providing and fixing precoated galvanised steel sheet roofingaccessories , Zinc coating 120gsm as per IS: 277 in 240mpa steelgrade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns using self drilling/ self tappingscrews or with polymer coated J or L hooks, bolts and nuts and orG.I. seam bolts and nuts, G.I. plain and bitumen washers complete :
-
-
-
Ridges plain (500 - 600mm).
-
-
-
Precoated galvanised iron profile sheets 0.50 mm thick
21
-
-
Gutter (600 mm over all girth).
-
-
-
Precoated galvanised iron profile sheets 0.50 mm thick
42
-
-
Providing and fixing 1st quality ceramic glazed wall tilesconforming to IS : 15622 (thickness to be specified by themanufacture of approved make in all colours, shades exceptburgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thickbed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm including pointing inwhite cement mixed with pigment of matching shade complete
13.2
-
-
Providing and laying Ceramic glazed floor tiles 300x300 mm(thickness to be specified by the manufacturer) of 1st qualityconforming to IS : 15622 of approved make in colours such asWhite, Ivory, Grey, Fume Red, Brown laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) including pointing thejoints with white cement and matching pigment etc., complete
12.62
-
-
Providing and applying white cement based putty of averagethickness 1mm,of approved brand and manufacturer, over theplastered wall surface to prepare the surface even and smoothcomplete.
149.52
-
-
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications :
-
-
-
Two or more coats applied @ 1.25 ltr/10 sqm. over and includingone coat of Special primer applied @0.75 ltr/10 sqm.
149.52
-
-
Providing and fixing aluminium handles, ISI marked,anodised(anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour or shade with necessaryscrews etc. complete :
-
-
-
125 mm
2
-
-
Providing and fixing aluminium sliding door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete :
-
-
-
250x16 mm
2
-
-
Providing and fixing aluminium tower door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete :
-
-
-
i)300 x 16 mm
2
-
-
Providing and fixing IS : 12817 marked stainless steel butt hinges(heavy weight) with stainless steel screws etc. complete :
-
-
-
125x64x2.50 mm
2
-
-
Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) andfitting the same with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessary accessories &stainless steel dash fasteners , stainless steel bolts etc., of requiredsize, on the top of the floor or the side of waist slab with suitablearrangement as per approval of Engineer-in-charge, (for paymentpurpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts,fasteners etc.).
-
-
-
Ingrating,frames, guardbar, railing, brackets, gates and similar works.
76.76
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
-
-
-
External work
-
-
-
25 mm nominal outer dia Pipes
60
-
-
50 mm nominal outer dia Pipes
130
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with sealring conforming to IS :5382 leaving 10 mm gap for thermalexpansion, (i) Single socketed pipes
-
-
-
75 mm diameter
25
-
-
White Vitreous China Wash basin size 630x450 mm with a single15 mm C.P. brass pillar tap
2
-
-
Providing and fixing white vitreous china pedestal type watercloset (European type W.C. pan) with seat and lid, 10 litre lowlevel white P.V.C. flushing cistern, including flush pipe, withmanually controlled device (handle lever), conforming to IS :7231, with all fittings and fixtures complete, including cuttingand making good the walls and floors wherever required :
-
-
-
W.C. pan with ISI marked white solid plastic seat and lid.
2
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap for thermal expansion
-
-
-
Single tee with door
-
-
-
75x75x75 mm
10
-
-
Bend 87.5
-
-
-
75 mm bend
10
-
-
2HP diesel water pump
1
-
-
Green net
5
-
-
Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceablematerialwithin 50 metres lead as per direction of Engineer-in-charge.
1.08
-
-
In Cement mortar
-
-
-
PVC septic tank (1000 ltr.)
1
-
-