Regional Institute Of Medical Sciences Tender
View complete overview of Manipur RIMS Tender
Regional Institute Of Medical Sciences - RIMS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date22 Dec 2023
Closing Date2 Jan 2024
Tender Amount₹ 67,84,822
Costs
EMD
₹ 1,35,696Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_RIMS_786836_1Bid Award Id
ViewTender No
200/2023-24/RIMS/ImphalTender Authority
Regional Institute Of Medical Sciences ViewPurchaser Address
-Website
http://http://www.rims.edu.in/secure/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
980
-
-
Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead.
-
-
-
For thickness of tiles above 10 mm and upto 25 mm
4.01
-
-
Dismantling wooden boardings in lining of walls and partitions,excluding supporting members but including stacking within 50metres lead
-
-
-
Upto 10mm thick
46.9
-
-
Thickness above 25 mm upto 40mm
25.5
-
-
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China)including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
5
-
-
Dismantling old plaster or skirting raking out joints and cleaningthe surface for plaster including disposal of rubbish to thedumping ground within 50 metres lead.
18.28
-
-
Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceablematerialwithin 50 metres lead as per direction of Engineer-in-charge.
-
-
-
In Cement mortar
10.26
-
-
Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within50 metres lead :
-
-
-
Of area beyond 3.00 sqm
6
-
-
E/W in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width pr 10sqm on plan) i/c dressing of sides & ramming of bottoms, lift upto 1.5m, i/c getting out excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
-
-
-
a) All kinds of soil
65.6
-
-
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
21.87
-
-
Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete.
1.26
-
-
Open timbering in case of shafts, walls, cesspits, manholes and like including strutting and shoring complete (measurement to be taken of the face area timbered).
-
-
-
Depth exceeding 1.5 m but not exceeding 3 m
17.6
-
-
Dry boulder flooring
10.56
-
-
Treatment of soil by boring, filling and compacting granular materials with the following specification i) boring by bailer with casing at required spacing and of required depth and stone column
136
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering
-
-
-
All works upto plinth level
-
-
-
1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
4.44
-
-
1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mmnominal size)
6.44
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work upto plinth level :
-
-
-
1:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nom size )
2.03
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral staircases upto floor two level excluding the cost of centering, shuttering, finishing and re-inforcement with
-
-
-
1:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nom size )
1.8
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, butresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement.
-
-
-
1:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nom size )
0.54
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Upto plinth level (b) Tor Steel Bars.
1416.51
-
-
Centering and shuttering including strutting, proppong etc. and removal form for
-
-
-
a) Foundations, footings, bases of columns etc. and mass concrete
3.93
-
-
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12mm.
12
-
-
c) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
3.6
-
-
Brick work with Ist class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in :
-
-
-
Cement mortar 1:4 (1 cement: 4 coarse sand)
12.52
-
-
Providing wood work in frames of doors,windows,clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length(hold fast lugs or dash fastener shall be paid for separately :
-
-
-
Local best quality Uningthou wood
1.01
-
-
Renewing glass panes and refixing existing wooden fillets
-
-
-
Float glass panes of thickness 4 mm
6.44
-
-
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately,allcompleteas per direction of Engineer-in-charge.
-
-
-
Local best quality Tolhao wood.
-
-
-
35 mm thick shutters
9.24
-
-
25 mm thick plank walling (Tolhao local best quality) and Tolhaowood beading 62mm x 12mm i/c fitting and fixing with necessaryscrews and nails complete (frame work to be paid separately).
120
-
-
Providing and fixing tiled False Ceiling of approved materials ofsize 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanized @ 120 gsm/sqm, both side inclusive) consisting of main“T” runner with suitably spaced joints to get required length andof size 24x38mm made from 0.30mm thick (minimum) sheet,spaced at 1200mm center to center and cross “T” of size 24x25mmmade of 0.30mm thick (minimum) sheet, 1200mm long spacedbetween main “T” at 600mm center to center to form a grid of1200x600 mm and secondary cross “T” of length 600mm and size24x25mm made of 0.30 mm thick (minimum) sheet to beinterlocked at middle of the 1200x600mm panel to form grids of600x600mm and wall angle of size 21x21x0.3 mm and laying falseceiling tiles of approved texture in the grid including, requiredcutting/making, opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc. Main “T” runners to besuspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dashfasteners, 4mm GI adjustable rods with galvanised butterfly levelclips of size 85 x 30 x 0.8 mm spaced at 1200mm center to centeralong main T, bottom exposed width of 24mm of all T-sectionsshall be pre-painted with polyester paint, all complete at allheights as per specifications, drawings and as directed by Engineer-in-Charge. (The rate is excluding the cost of tiles which will be paid
-
-
-
GI Metal ceiling Lay in plain Tegular edge Global white color tiles of size 595 x 595 mm, and 0.5 mm thick with 8 mm drop, made of GI sheet having galvanizing of 100 gms/sqm( both sides inclusive) and electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending
767.25
-
-
Providing and fixing hand rail of approved size by welding etc.to steel ladder railing,balcony railing and stair case railing including applying a priming coat of approved steel primer.
-
-
-
M.S. tube
12.42
-
-
52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume .hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
8.6
-
-
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.
-
-
-
Size of Tile 600 x 1200 mm
9.5
-
-
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)with zinc coating 120 grams per sqm as per IS: 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto12 metre or as desired by Engineer-in charge. The sheet shall befixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
-
-
-
Precoated galvanised iron profile sheets 0.40 mm thick
1093.43
-
-
Providing and fixing precoated galvanised steel sheet roofingaccessories , Zinc coating 120gsm as per IS: 277 in 240mpa steelgrade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns using self drilling/ self tappingscrews or with polymer coated J or L hooks, bolts and nuts and orG.I. seam bolts and nuts, G.I. plain and bitumen washers complete
-
-
-
Ridges plain (500 - 600mm)
-
-
-
Precoated galvanised iron profile sheets 0.50 mm thick
47.33
-
-
Steel work in built up tubular (round,squareorrectangulartubesetc.)trussesetc.,includingcutting,hoisting fixing in position and applying a priming coat of approved steel primer,including welding and bolted includings pecials haped washers etc.complete
-
-
-
Hot finished welded type tubes
13028.55
-
-
Providing fixing upto five floor level hard drawn steel wire fabric 75x25mm mesh of weight t not less than 7.75kg/sqm to the cat walk steel frame with site ralling upto 0.75m and binding with 3mm of GI wire and laying 12 mm water proof ply and fixing with galvanised steel bolts 10mm dia an 7cm long with nuts as directed by the Engineer in charge.
16.2
-
-
Providing and fixing 15 cm wide 45cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete.
-
-
-
0.80 mm thick with Zinc coating not less than 275gm/m2
17.7
-
-
12 mm cement plaster of mix:
-
-
-
1:4 (1 cement : 4 fine sand)
174.9
-
-
Neat cement punning
48.14
-
-
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
94.12
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
-
-
-
Water thinnable primer
94.12
-
-
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.
-
-
-
Two or more coats on new work-
94.12
-
-
Finishing walls with Acrylic Smooth exterior paint o frequired shade
-
-
-
New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. overand including base coat of water proofing cement paint applied @2.20 kg/ 10 sqm).
1720.06
-
-
Applying priming coat
-
-
-
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
1011.14
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
-
-
-
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
3230.23
-
-
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge
-
-
-
75mm dia
108
-
-
110mm dia
218
-
-
Providing and fixing white vitreous china pedestal type watercloset (European type) with seat and lid, 10 litre low level whitevitreous china flushing cistern & C.P. flush bend with fittings &C.I. brackets, 40 mm flush bend, overflow arrangement withspecials of standard make and mosquito proof coupling ofapproved municipal design complete, including painting offittings and brackets, cutting and making good the walls andfloors wherever required :
-
-
-
W.C. pan with ISI marked white solid plastic seat and lid.
5
-
-
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tubeupto 1 metre long with S.S. triangular plate to Eureopean typeW.C. of quality and make as approved by Engineer - in - charge.
5
-
-
ProvidingandfixingG.I.inletconnectionforflushpipeconnecting with W.C. pan
5
-
-
Providing and fixing 600x450 mm beveled edge mirror ofsuperior glass (of approved quality) complete with 6 mm thickhard board ground fixed to wooden cleats with C.P. brass screwsand washers complete.
3
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
-
-
-
450 mm long towel rail with total length of 495 mm, 78 mm wideand effective height of 88 mm, weighing not less than 170 gms.
2
-
-
Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V.stabilized with carbon black having thermal stability for hot & coldwater supply, capable to withstand temperature up to 80°C,including all special fittings of composite material (engineeringplastic blend and brass inserts wherever required) e.g. elbows,tees, reducers, couplers & connectors etc., with clamps at 1.00metre spacing. This includes testing of joints complete as perdirection of the Engineer in charge.
-
-
-
INTERNAL WORK - EXPOSED ON WALL
6
-
-
Providing and fixing brass bib cock of approved quality :
-
-
-
15 mm nominal bore
5
-
-
32 mm nominal bore
3
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
-
-
-
100mm nominal outer dia Pipes
16.2
-
-
Hiring and installtion of scaffolding (excluding the costs of materials)
490
-
-
Evaluation Notes How It Works ?
Potential Partner