Public Works Department Tender

Take tender evaluation notes for Manipur PWD Tender

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date8 Apr 2025
Closing Date22 Apr 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Construction Of Rigid Pavement With Thin White Topping In Chandel District Hq Roads And Construction Of Pavement With Interlocking Paver Blocks In Chandel District Hq Roads.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.) (i) Single row for one utility service

9.9

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

172.41

-

-

... More
Construction of thin white topping with plain cement concrete pavement over existing surface with approve grade cement @ 400 kg per cum as per IRC SP-76 coarse and fine aggregate conforming to IS 383, maximum size of fine aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design of M40 Cement COncrete, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction joint, joint filler,sealant primer, joint sealant, admixtures as approved, curing compound, finishing to lines and grades as per drawing

344.81

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)

183.9

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

0.4

-

-

... More
Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973)

177

-

-

... More
SH:- Improvement of road from DC Lamkhai to CJM Court, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1518.75

-

-

... More
Providing laying and compacting Granular Base/Sub base according to lines, grades and cross sections by using naturally occuring Sand Gravel/conforming to IRC-Grd-II of MOST specification free from organic or other deleterious constituents spread with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness) i/c rolling of the road surface to proper level and grades 30 cm width edging on both side etc. complete as directed by Engineer-in-charge.

72.9

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.) (i) Single row for one utility service

9.9

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

113.91

-

-

... More
Construction of thin white topping with plain cement concrete pavement over existing surface with approve grade cement @ 400 kg per cum as per IRC SP-76 coarse and fine aggregate conforming to IS 383, maximum size of fine aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design of M40 Cement COncrete, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction joint, joint filler,sealant primer, joint sealant, admixtures as approved, curing compound, finishing to lines and grades as per drawing

227.81

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)

121.5

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

0.27

-

-

... More
Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973)

171

-

-

... More
SH: Improvement of PWD Approach Road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1143.75

-

-

... More
Providing laying and compacting Granular Base/Sub base according to lines, grades and cross sections by using naturally occuring Sand Gravel/conforming to IRC-Grd-II of MOST specification free from organic or other deleterious constituents spread with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness) i/c rolling of the road surface to proper level and grades 30 cm width edging on both side etc. complete as directed by Engineer-in-charge.

54.9

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.) (i) Single row for one utility service

9.9

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

85.78

-

-

... More
Construction of thin white topping with plain cement concrete pavement over existing surface with approve grade cement @ 400 kg per cum as per IRC SP-76 coarse and fine aggregate conforming to IS 383, maximum size of fine aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design of M40 Cement COncrete, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction joint, joint filler,sealant primer, joint sealant, admixtures as approved, curing compound, finishing to lines and grades as per drawing

171.56

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)

91.5

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

0.2

-

-

... More
Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973)

73

-

-

... More
SH: Improvement of District Hospital Road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1136.25

-

-

... More
Providing laying and compacting Granular Base/Sub base according to lines, grades and cross sections by using naturally occuring Sand Gravel/conforming to IRC-Grd-II of MOST specification free from organic or other deleterious constituents spread with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness) i/c rolling of the road surface to proper level and grades 30 cm width edging on both side etc. complete as directed by Engineer-in-charge.

54.54

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.) (i) Single row for one utility service

9.9

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

85.22

-

-

... More
Construction of thin white topping with plain cement concrete pavement over existing surface with approve grade cement @ 400 kg per cum as per IRC SP-76 coarse and fine aggregate conforming to IS 383, maximum size of fine aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design of M40 Cement COncrete, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction joint, joint filler,sealant primer, joint sealant, admixtures as approved, curing compound, finishing to lines and grades as per drawing

170.44

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)

90.9

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

0.2

-

-

... More
Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973)

84

-

-

... More
SH: Improvement of Salemthar Industrial Estate Approach road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1177.5

-

-

... More
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic or other deleterious constituents spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)

56.52

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.)

4.95

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

88.31

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and technical Specifications (F) PCC Grade M20 using batching plant & Manual placing

9.75

-

-

... More
Providing and laying factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. i) 80mm thick

1083.3

-

-

... More
SH: Improvement of District Industrial Centre Approach road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1181.25

-

-

... More
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic or other deleterious constituents spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)

56.7

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.)

4.95

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

88.59

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and technical Specifications (F) PCC Grade M20 using batching plant & Manual placing

9.54

-

-

... More
Providing and laying factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. i) 80mm thick

1086.75

-

-

... More
SH: Improvement of ADC Chandel Road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1567.5

-

-

... More
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic or other deleterious constituents spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)

75.24

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.)

9.9

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

117.56

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and technical Specifications (F) PCC Grade M20 using batching plant & Manual placing

12.54

-

-

... More
Providing and laying factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. i) 80mm thick

1442.1

-

-

... More
SH: Improvement of DFO Approach Road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

1181.25

-

-

... More
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic or other deleterious constituents spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)

56.7

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.)

4.95

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

88.59

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and technical Specifications (F) PCC Grade M20 using batching plant & Manual placing

9.6

-

-

... More
Providing and laying factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. i) 80mm thick

1086.75

-

-

... More
SH: Improvement of SDO Office approach Road, Chandel

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

783.75

-

-

... More
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic or other deleterious constituents spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)

37.62

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.)

4.95

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

58.78

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and technical Specifications (F) PCC Grade M20 using batching plant & Manual placing

6.63

-

-

... More
Providing and laying factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. i) 80mm thick

721.05

-

-

... More
SH: Improvement of road In & Around Japhou Bazar, Chandel.

-

-

-

... More
Scarifying the existing bituminnous road surface to a depth of 50mm and disposal of scarified material with all lifts and lead upto 1000 metres. (i) Mechanical means using hydraulic excavator.

15506.25

-

-

... More
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic or other deleterious constituents spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)

744.3

-

-

... More
Cable duct across the road (provding and laying of a rcc pipe duct, 300 mm dia across the road (new constructon), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm iin case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher tha ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings.)

4.95

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.

1162.97

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and technical Specifications (F) PCC Grade M20 using batching plant & Manual placing

124.05

-

-

... More
Providing and laying factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. i) 80mm thick

14265.75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.