North Central Railway Tender

View complete overview of Manipur NCR Tender

North Central Railway - NCR Tender

Works
Machinery and Tools
Ireps
Opening Date26 Nov 2024
Closing Date19 Dec 2024
Tender Amount₹ 20,37,661.81 
Notes
Download

Costs

Summary

Provision Of S&t Work In Connection With Construction Of Rob In Lieu Of Lc No S-1 At Km 1310/5 At Ch.203.009 Of Nh-76 In Between Ichauli-khairar Station Of Khairar- Bhimsen Section.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, testing and commissioning of Sliding type mechanical Boom barrier (SBB) assembly, 11 to 12 Meter Long, movement drive mechanism, an resetting & supporting 4 stand suitable for Mechanical/Electrical level crossing gate as emergency arrangement as per GZB Workshop drawing no. SA- SWG/GZB/E/01 or latest. The sliding boom assembly should be have the provision of 50mmx50mmx50mm angles for the entire length. Boom rest posts should be 10 no per gate or more as per site requirement. Painting should be completely done of all the assemblies/parts of Sliding LC gate. (Inspection Agency:- Consignee).

1

185951

185951.71

... More
Supply of electrically operated lifting barrier assembly complete RDSO spec no. 5 RDSO/SPN/208/2012 Ver. 2 with amend.1 or latest. Each consisting of 2 Nos. of electrically operated. Lifting barriers, 2 pedestal, 8 band circuit controller with limit switch, hand cranks, 2 electric motors 110V AC 0.5HP without centrifugal switch, 2 Nos. of GI boom of 10 mtrs. Long with telescopic jointing arrangement as per drg. No. RDSO/S 11600 or latest, with 2 stop boards, boom light boxes, MS counterweights and 2 Nos. of boom supports for resting of motorized booms and boom locking assembly along with contactor units, gate control panel, indication panel on sheet metal fabricated box with switches and buttons to operate the gate crank handling arrangement, circuit controller, terminals etc as per RDSO Spn. IRS: S41/70 (Amd.2) or latest. The installation, material and quality of material like should be strictly as per Railway's requirement at site. (Inspection Agency:- RDSO).

1

267166

267166.69

... More
Supply of 1 x 6 Sq mm (Red/Black) multi strand copper power wire , 85 conductor 6 each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest.Colour of the wire will be specified by the Engineer incharge. Material to be procured from RDSO approved firm . (Inspection Agency:- Consignee).

500

45

22950

... More
Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway 7 signaling suitable for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Inspection Agency:- Consignee).

4

34211

136845.64

... More
Supply, installation, testing and commissioning of LED type control cum indication panel complete with prewired Tag- Blocks, Wires MS angles etc. for LC gate , depicting the yard layout Signal, Point, Track circuit, Operating / emergency Push Button, counter with sealing 8 arrangements, house in a Steel 27 28 29 30 31 32 metal cabinet. This shall be consist 15 x 10 exchangeable Domino Unit as per Spec. SPN/186/2004 Rev. 2.0 or latest. The indoor wiring inside panel shall be terminated on tag block as per instructions of Engineer-in-charge. The wiring on panel tag blocks shall be repeated on tag blocks located in relay room. This includes laying & termination of cable, if any from Panel Room to Relay Room in HDPE pipe. (Inspection Agency:- Consignee).

1

62941

62941.58

... More
Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized, metal to metal, with different ward combinations and contact configuration 4F/4B with 2 extra ward plates, RDSO spec no. RDSO/SPN/219/2016 Ver 1.0 with Amendment-1 or latest. (Inspection Agency:- RDSO).

2

7680

15361.2

... More
Supply and installation of prewired KLCR Box, wooden crank handle lock inside box, 10 with 8 way terminal strips, LEDs of approved type, for fixing of EKT on wooden board inside box form installating KLCRs/EKTs up to 06 no., including supply of all material like board, handle, hinges, glass sheet etc. (Inspection Agency:- Consignee).

2

13048

26096.62

... More
Supply and Installation of Glass fronted Key box for Crank handle etc.It should be done as per site supervisor instructions. (Inspection Agency:- Consignee).

2

2353

4706.06

... More
Supply of Road signal complete with signal post CLS unit 3 aspect ,ladder ,Base , LED signals & Hooter etc. (Inspection Agency:- Consignee).

2

57948

115896.7

... More
Supply of Desk type Electronic Magneto telephone as per spec. No. IRS TC: 79/2000 (Amndt.4) or latest. (Inspection Agency:- Consignee).

2

3524

7049.98

... More
Supply and fixing of 50 pair Krone termination DP duly fitted with disconnection type. (Inspection Agency:- Consignee).

4

6225

24903.44

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly fi lled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. (Inspection Agency:- RDSO).

5

3454

17272.25

... More
Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or 16 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. (Inspection Agency:- Consignee).

4

19054

76219.08

... More
Supply and installation of Cable Termination(CT) rack as per drawing of NC Railway, 17 complete along with fitting arrangements, wall supports, scaff olding and suitable grounding arrangements and also with arrangement for fi xing four 8-way terminal strips/ Screw less terminals/ ARA terminals. Th e CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fi xing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals Not covered under this item. Cable termination rack shall be corrosive resistant and powder coated. (Inspection Agency:- Consignee).

1

46240

46240.98

... More
Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base 18 plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09- 2002 ,Amdt.-1 or latest and RDSO Spec.No.IRS:S 45"44 S-23 or latest, as applicable. The interlocking code for this unit shall be ""ABDHK"". (Inspection Agency:- RDSO).

5

6522

32612.3

... More
Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board 19 (base plate), connectors, retaining clips etc. and conforming to BRS-931A and RDSO Specn. No.IRS:S - 34 ,S-23,S-60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH". (Inspection Agency:- RDSO).

5

4264

21323

... More
Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and Non flame propagating type in 6 meter straight length and of size 120 mm outer dia, & 103.5 mm inner dia. 20 (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. (Inspection Agency:- Consignee).

120

628

75392.4

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. (Inspection Agency:- Consignee).

1

75382

75382.72

... More
Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 22 mtr deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Inspection Agency:- Consignee).

10

3302

33021

... More
Relay Time Element Clock type / Fail safe Electronic Timer conforming to IRS: S61 / 2000 with Amend. 2 or latest / or equivalent with base, for time delay of 30 / 60 / 120 / 180 / 240 seconds (as specified) and to work on 110V AC or 60 V C. (Inspection agency:-Consignee)

1

7340

7340.72

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full (App. Case as per RDSO drg. no. RDSO/S-11500 or latest) with contractor's own frame, 1 cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

2

11748

23496.4

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 2 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately).

1000

17

17330

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work.

-

-

3

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like 4 ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full).

2

4285

8570.6

... More
Installation, testing and commissioning of electrically operated lifting barrier, 5 complete with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc.

1

53286

53286.49

... More
Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways.

115

52

6012.2

... More
Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR drg.No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR Letter No. S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized 7 anchor bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. No. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor.

4

13261

53044.36

... More
"Preparation & submission of cable route plan of main & tail cables , cable corage plan, location particulars, CT rack particulars, meggering report , earth resistance particulars, traction bonding diagram ,panel diagram and any other drawing / particulars required in auto CAD in 8 minimum A3 size each sheet should have a block for signature of Railway officials as well as block for signature of the firm, where signature shall be put up by the authorized signatory of the firms. The name of the work as given by the Railway shall be written on every sheet under the work column. One compete set of tracings and four sets of copies of complete above detailed particulars / drawing alog with one CD to be supplied by the contractor in thick plastic folders.

1

30490

30490.15

... More
Wiring in relay room/ location box fixing of Q series relay base plate/ metal to metal relay mini group and major group base plates, laying lacing dressing & packeting of 60/40 core PVC indoor cable/ flexible wire and termination of 60/40 core cable/ flexible wire on tag block/ base plate & soldiering. wiring of circuits to be done as per rly.site engineer] on relay interlocking system using metal to metal / metal to carbon type relay and soldering after testing. This also includes fuse wiring, 9 function wiring ( interconnection between relay rack & 0.6mm , 1.0mm RDSO spec. no IS 694/1990, S :76/89 or latest and should be procured form RDSO approval sources and 16/0.02 multi strand flexible etc.resin core, solder wire , lacing thread adhesive tapes , resistance, condensers, diodes, lugs etc of various ratings and capacity as per site requirement will be supplied by the contractor free of cost and will be sued after approval of Rly engineer at site. The jumper wire required for carrying out the indoor work shall be supplied by contractors wire should be assessed jointly with the engineer in charge at the beginning itself. The work shall be done as per approved plan extant practice on N C rly & the instruction of Rly engineer at site unit per tag block / number).

5

1001

5006.4

... More
Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77- 2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly fi lled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer.

5

1806

9030.7

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from 11 the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore.

50

1036

51828

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half).

2

593

1186.86

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like 13 ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Half).

4

2324

9298

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Half (App. Case as per RDSO drg. no. RDSO/S-11507 or latest) with contractor's own frame, 14 cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case.

4

9886

39546.16

... More
Digging of 01 Meter deep and 300MM wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per technical specifications and cable route plan. Note:In case where digging of trench up to 01 Meter depth and 300MM wide is not possible or bigger size trench is required to lay more cables or loose soil/ muck is encountered, 15 the depth can be reduced / increased as per directions of the Engineer-in-charge of the works, the payment will be decreased/increased proportionate to the depth & width of excavation compared to 01 Meter deep and 3 MM wide. This also includes Back filling and consolidating of cable trench first for 5 CM (in case where bricks are to laid over cables) after laying of cables and then complete back filling & Ramming of loose soil as per the technical specifications. In all type of soils] including soft rock.

500

49

24715

... More
Dismantling and Releasing of existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fi ttings. All the released material will be transported to the SSE/Consignee depot.

6

1046

6277.38

... More
Dismantling and Releasing of existing Signals (both electrical and Mechanical) and other associated S&T fi ttings like wheel, pulleys, wires, stakes etc. All the released material will be transported to the SSE/Consignee depot.

2

1646

3292.76

... More
Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like calling on, shunt signal if any. It includes fixing of all LEDs and wiring 18 of complete signal including route and auxilliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge.

2

5627

11255.44

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, 19 coarse, sand and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor.

5

4889

24446.05

... More
Development and preparation of SIP, SWRD/GWRD,SWR etc based on existing GAD/SIP/ESP .(For station/LC upto 4 lines) Job= Per stn/LC.

1

22595

22595.71

... More
Drawing of wiring circuit in A-3 size sheet in autocad.(02 sets photo copy & 01 set tracing with soft copy) .

18

660

11880

... More
Laying of Double Wall Corrugated (DWC) pipe of all sizes with socket, coupler and T 22 Joint etc. by digging of trench 0.3 Meter width, 1.2 Meter depth from rail flange under track for track crossing and refilling after laying of pipes, as per technical specifications and the restoration of disturbed ballast by screening and dressing as per instruction of Engineer-in- charge or his representatives at site.

120

82

9906

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in the ratio 1:3. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor.

-

-

23

... More
Laying of Armoured Optical Fiber OFC through PVC Pipe/Casing capping and termination in LIUs & FDMS wherever required.

1000

18

18700

... More
Laying of HDPE duct as per the approved cable route plan in the exavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, 25 bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6(a) and RDSO/TCDO/COP-8(a) respectively, issued vide Chapter-XIII of the Telecomm Manual.

1

7941

7941.73

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 26 laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

3000

6

19620

... More
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 27 concreting it afterwards as per original condition. In hard rocky ground area , cables will be laid normally on layer of soft earth of 0.05 mtrs thickness previously deposited at bottom of the trench . The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. 28

30

152

4560.6

... More
Cross trench for identification of the route of existing signalling and telecomm cables.

55

285

15675.55

... More
Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit.

4

83

335.92

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full).

2

652

1305.06

... More
Dismantling and Releasing of existing Electrically operated LC gate/Mechanically operated LC gate and other associated S&T fittings. All the released material will be transported to the SSE/Consignee depot.

2

8403

16807.7



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.